NDBC’s SCOOP System Barometer Specification

The National Data Buoy’s SCOOP system barometer is intended to be used on the NDBC’s next generation buoy system as an extended (redundant) meteorological instrument. This barometer is installed in the CAMETPLD housing and has limited space for the installation and must have low input power requirements. This barometer must also maintain its accuracy over a wide range of temperatures as the SCOOP systems are design to be deployed as far as Alaska and as far South as the equator. The SCOOP barometer must undergo and pass NDBC laboratory testing to verify its performance characteristics and then pass field testing to ensure it can with stand installation on a constantly moving platform.

The NDBC first certified the R.M. Young model 61302V-1 for operational use in the SCOOP system in late 2015. In fiscal year 2017 the NDBC worked with Setra to make slight modifications to their model 278 barometer to get it to meet the NDBC SCOOP Requirements. The model 278 barometer was certified for use in the SCOOP system in late fiscal year 2017.

The NDBC uses the R.M. Young 61302V-1 or the Setra 2781800MA1B2BZZNDB2 or an equal that meets the following requirements:

Electrical Specifications

Input Voltage Range
10 to 16 VDC min
Current Consumption
3 mA max nominal, 1.5 uA max in sleep mode
Range
800 to 1100 hPa (mb)
Output
0 to 5 VDC
Long Term Stability
0.12 hPa (mb)
Accuracy
+/- 0.75 hPa (mb) over -20° C to +45° C range
Resolution
At least 0.075 hPa (mb) over 800 to 1100 hPa (mb) range
Warm-up
<1 second from power on
Operational Temperature
-40 C to +60 C
Acceleration Sensitivity
Unit to be mounted on moving platform. As such, it can have no sensitivity to accelerations of the unit.
Connector
3” Pigtail plain or Prefer with Molex Micro-fit 43020-0600 connector with Molex 43031-0002 pins with following pinout:

Pin 1 – External Trigger / RX Pin 2 – Signal Reference Pin 3 – Power Return Pin 4 – Power (+) Pin 5 – Analog Signal / TX

Physical Specifications

Weight
< 5 oz.
Size
3.6” x 2.4” x 1.0”
Mounting
Two # 6 Screws 3.0” apart
Pressure Port
1/8” Barbed Fitting