RFI for NWR Upgrade Project

Request for Information (RFI) for

NOAA Weather Radio (NWR) Upgrade Project (NWRUP)

Contracting Office Address

NOAA Acquisitions & Grants Office (AGO)

Description

PURPOSE: The National Oceanic and Atmospheric Administration (NOAA), National Weather Service (NWS) is conducting market research to determine sources with competencies to support the NOAA Weather Radio (NWR) Upgrade Project (NWRUP). The goal of NWRUP is to upgrade the telecommunications infrastructure used to disseminate NWR content from at least 122 Weather Forecast Offices (WFO) to over 1000 very high frequency (VHF) transmitter sites;

including the monitoring and control system(s) for the equipment at those VHF transmitter sites.

The NWS Dissemination Systems Team (DST) is issuing this Request for Information (RFI) to elicit feedback from the industry regarding alternative solutions that address NWRUP programmatic and budgetary requirements and to inform interested parties of the nature of the planned acquisition.

Disclaimer

THE GOVERNMENT DOES NOT INTEND TO AWARD A CONTRACT ON THE BASIS

OF THIS RFI OR REIMBURSE ANY COSTS ASSOCIATED WITH THE PREPARATION

OF RESPONSES TO THIS RFI.

This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI marked Proprietary will be handled accordingly. Responses to the RFI will not be returned. Whatever information is provided in response to this RFI will be used to assess tradeoffs and alternatives available for determining how to proceed in the acquisition process for a NWR Upgrade Program capability. In accordance with FAR 15.201(e), responses to this RFI are not offers and cannot be accepted by the Government to form a binding contract.

This RFI is a request for interested parties to describe their technical capabilities and demonstrated tools, processes, and service capabilities. All interested contractors are requested to provide written response to the questions below. A response to this RFI is necessary in order to assist NWS in determining the potential levels of interest, adequacy of competition, and market maturity and technical capabilities within the business community to provide the required capabilities.

CONTENTS

DESCRIPTION

DISCLAIMER

1.0 INTRODUCTION

2.0 NOAA WEATHER RADIO (NWR) OVERVIEW

3.0 NWR UPGRADE PROJECT (NWRUP) HIGH-LEVEL REQUIREMENTS

3.1 DISSEMINATION SYSTEM UPGRADES

3.2 MONITORING AND CONTROL SYSTEM UPGRADES

3.3 ENVIRONMENTAL REQUIREMENTS

3.3.1 Non-Transmitter Site (Office Environment) Equipment

3.3.2 Transmitter Site Equipment

3.4 UPGRADE PROJECT CONSIDERATIONS

4.0 REQUESTED INFORMATION

5.0 SUBMISSION INSTRUCTIONS

5.1 VENDOR IDENTIFICATION

5.2 RESPONDING TO THIS RFI

5.3 FORMAT

5.4 TECHNICAL POINTS OF CONTACT

APPENDIX A – REFERENCES

APPENDIX B – ACRONYMS

1.0 INTRODUCTION

The National Oceanic and Atmospheric Administration (NOAA) National Weather Service (NWS) currently provides forecasts and weather information, weather watches, warnings and other emergency messages to the public and emergency managers through the NOAA Weather Radio All-Hazards (NWR) network and NOAA Weather Wire Service (NWWS). The primary purpose of these systems is to reliably deliver All-Hazards emergency warnings to those people most immediately at risk, with sufficient lead time to allow them to take action to reduce the likelihood of property damage, injury or death. This RFI addresses planned upgrades to NWR (NWWS is not in scope). Section 2 provides an overview of the current NWR dissemination system, and Section 3 provides high-level requirements for the desired upgraded NWR system.

Section 4 enumerates specific questions for NWS would like to elicit responses from industry sources.

2.0 NOAA Weather Radio (NWR) Overview

Today’s NWR is a nationwide system that comprises over 1000 very-high-frequency (VHF) radio frequency (RF) transmitters covering the United States, US territories (Guam, Northern Mariana Islands, Puerto Rico and Virgin Islands, etc.), and the respective adjacent waterways and coastal areas. The system continuously broadcasts weather information and forecasts 24 hours a day, 7 days a week, 365 days a year. Severe weather warnings, watches, advisories, and other hazard information are broadcast whenever they occur. The NWR is an “all hazards” radio network, making it a key source of comprehensive weather and emergency information. This broadcast system is also available to local, state, regional, and national emergency managers for disseminating non-weather emergency warnings (via All Hazards Collection System). Figure 1 depicts the current NWR system.

Weather data is collected by Weather Forecast Offices (WFO), which create the forecast and warning products. These products are currently converted from text to audio by the WFOs Broadcast Message Handler (BMH) system integrated into NOAA’s Advanced Weather Interactive Processing System (AWIPS). In addition, a set of indicators are used for warnings and alerts. These indicators take the form of tones and frequency-shift keying (FSK) to specify which geographic area the product addresses and are disseminated to NWR transmitters in audio form using leased analog telephone circuits or point to point radio frequency links. The message format shall comply with the NOAA Weather Radio All Hazards Specific Area Message Encoding (SAME) [NWS Directive 10-1712; see Appendix A] and FCC Part 11.31 standards

There are more than 100 WFOs. Each WFO serves a number of transmitter sites. In the event of an outage, backup WFOs are able to service transmitter sites normally serviced by other WFOs.

A number of WFOs are grouped to form 6 regions. Headquarters is responsible for all 6 regions and the more than 1,000 transmitters in service.

NWR transmitters can be monitored and controlled locally at the transmitter site with the indigenous system controller within the transmitter itself. NWR transmitters may also be controlled with proprietary software programs unique to each type of transmitter that run on laptop computers. These laptop computers may be used locally by connecting directly to the system controller or remotely by dialing in with a modem. NWR currently employs Nautel, Armstrong-2010 B Series, Armstrong Classic, and CROWN/CEC transmitters. The software programs associated with the transmitters are indicated in the following table:

Transmitter Software Nautel NG Series (NG300/NG1000) Remote Software Armstrong B and Classic (G300/G1000/G300B/G1000B)

Telecon Remote Software

CROWN (WR300/WR1000) Gentner Remote Software CEC (WR300B/WR1000B) Remote Control Software

In addition to these proprietary software programs, some limited remote monitoring and control (M&C) functions are possible. The Remote Off-Air Monitoring System (ROAMS) at NWR transmitter sites is accessed via a separate analog telephone line. ROAMS is programmed to initiate a call to the WFO when the transmitter malfunctions and report the problem verbally to the WFO staff. ROAMS can also be accessed for limited remote troubleshooting from non- WFO locations via the telephone line. Although ROAMS installations are mounted differently at the various NWR transmitter sites, all ROAMS work the same way.

When an alarm condition is detected at the transmitter site, ROAMS can optionally use the telephone line to call the ROAMS Automated Management System (RAMS) which makes a determination as to the appropriate action. RAMS reports the problem at the transmitter site by voice telephone, E-mail and real time message posting on a website. RAMS also documents and archives all activities that take place in processing every ROAMS call and makes the data available for analysis.

• Maritime

• Government

• First Responders

• Law Enforcement

• General Public

• Hearing Impaired

• Broadcast Radio

• Broadcast Television

Public Broadcasting

Legacy Dissemination System (Analog Audio)

• TELCO leased line

• or UHF link

• or Other link

Advanced Weather

Interactive Processing

System

[AWIPS]

Transmitter Sites

Weather Forecast Offices (WFO)

Weather Data

Collection

NOAA Weather Wire Service (NWWS)

Other NOAA Services Public

Internet

• General Public

Transmitter Antenna

ROAMS

POTS Dial Line

• Control & Monitoring

• ROAMS

RSM

NWS Technician/Contractor Remote Monitor and Control Access

NWS Technician/Contractor Local Maintenance Access

BMH/

CRS

RC&M

Modem

RAMS

Figure 1: Current NWR System

BMH Broadcast Message Handler CRS Console Replacement System EAS Emergency Alert System POTS Plain Old Telephone Service RAMS ROAMS Automated Management System RC&M Remote Control & Monitor ROAMS Remote Off-Air Monitoring System RSM Remote SAME Monitor SAME Specific Area Message Encoding

3.0 NWR Upgrade Project (NWRUP) High-Level Requirements

3.1 Dissemination System Upgrades

The telecommunications infrastructure used to disseminate content to NWR transmitters comprises a set of leased analog telephone circuits (separate from ROAMS) and a number of point to point RF links. The first NWRUP requirement is to upgrade this legacy infrastructure.

The WFOs are already connected to the NOAA corporate network, which includes Internet gateways. The upgraded dissemination system shall provide network access for all transmitter sites; have high availability; support both voice and data; and use the Internet Protocol (IP).

Tradeoffs for the following issues should be addressed in RFI responses:

• Availability: from .995 to .99999

• Voice quality: Mean Opinion Scores (MOS) from 3 to 5

• Cost: both non-recurring and recurring

• Recommended bandwidth

3.2 Monitoring and Control System Upgrades

The second NWRUP requirement relates to the Monitoring & Control (M&C) system. RFI responses shall propose alternatives to ROAMS as a method of remote monitoring and control of the transmitter sites. The upgraded M&C system shall be hierarchical, with a local presence at each of the transmitter sites. Higher-level system elements at the regional headquarters shall provide consolidated status for all transmitter sites within a region. These higher-level systems shall provide a status dashboard with a geographic map of the sites contained; they shall also be capable of drilling down to the same level of detail for each transmitter site that is locally available. In addition, a graphical depiction of the transmitter and auxiliary equipment shall illustrate the status the various components. Finally, a global element shall exist at NOAA headquarters that assembles a complete status display from all the regional elements. This global element shall be capable of performing the same functions as each regional system element with the added feature of providing a summary report addressing outages and degraded systems by location.

In addition to the local, regional, and national offices, remote M&C capabilities shall also be available, e.g. off-site/on-the-road via a laptop or mobile device.

The local transmitter site M&C element shall provide the following interfaces:

• LAN (Ethernet)

• Asynchronous interface to transmitter (RS-232 and/or USB)

• Auxiliary Equipment (analog or discrete)

The local transmitter site M&C configuration shall perform the following functions:

• Store all status information in a configurable database such as a Standard Network Management Protocol (SNMP) Management Information Base (MIB)

• Respond to queries from higher level management system elements (at regional headquarters or at NOAA headquarters)

• Send alarms and alerts when appropriate to these higher management system elements

• Query the transmitter for status at a configurable time interval

• Switch from primary to secondary or vice versa or turning on/off individual transmitters at the site

• Determine the status of auxiliary systems at a configurable time interval

− Generator − Transfer Switch position − Fuel level − AC/Heating operation − Shelter Temperature − Go/No-Go alarm − Door or Access Alarm − Redundant Antenna switch position − Redundant Audio input switch position

• Command site generator to start or stop

The M&C system elements should utilize SNMP when communicating with other management system elements. RFI responses that propose SNMP shall address tradeoffs with SNMP versions and configurations. Alternatives to SNMP may also be proposed; however, if an alternative to SNMP is proposed, rationale shall be provided.

3.3 Environmental Requirements

The extreme conditions under which NWR transmitters operate sometimes necessitate stringent environmental requirements, which may impact proposed solutions to this RFI. Equipment shall be designed to minimize impact on NWS facilities and shall conform to the following specifications.

3.3.1 Non-Transmitter Site (Office Environment) Equipment

Indoor equipment shall be able to operate in the following conditions:

• Temperature: 0o C to 50o C

• Humidity: 10% to 92% Relative Humidity

• Combined Temperature and Humidity: 90o F/55% Relative Humidity

• Altitude: Sea level to 7,000 feet

• Dust: Typical of light industrial areas.

• Fungus: Typical of inland and coastal areas.

3.3.2 Transmitter Site Equipment

Indoor equipment at NWR transmitter sites shall be able to operate in the following conditions:

• Continuous operation in an ambient condition from -30° C to +50° C (-22° F to +122°F) in salt laden air.

• Humidity: 10% to 95% Relative Humidity

• Combined Temperature and Humidity: 90o F/55% Relative Humidity

• Altitude: Sea level to 7,000 feet

• Dust: Typical of light industrial areas.

• Fungus: Typical of inland and coastal areas.

3.4 Upgrade Project Considerations

The NWRUP will consist of two phases. Phase 1 is an exploratory phase with pilot test cases designed to demonstrate concepts and evaluate alternative solutions. Phase 2 will consist of implementation of the selected solutions throughout the infrastructure.

The purpose of this RFI is to identify effective alternative solutions to the outdated baseline and also to identify potential providers. Sites will be made available for appropriate concept demonstrations during Phase 1. Figure 2 illustrates a notional systems view for the upgraded NWR System. However, Figure 2 may be updated to reflect the best concept and solution alternatives after RFI responses are evaluated.

In addition, NWR Information Technology (IT) systems shall implement the appropriate FISMA information security controls noted in NIST Special Publication 800-53, Recommended Security Controls for Federal Information Systems, to meet the requirements for a moderate security categorization rating, as defined in NIST Federal Information Processing Standard Publication 199, Standards for Security Categorization of Federal Information and Information Systems.

Figure 2. Notional Systems View for the Upgraded NWR System

4.0 Requested Information

1. Provide a brief overview of any commercially available solutions that can meet the requirements in Section 3.

2. Describe means to address the functional differences between the various types of transmitters.

3. Describe the commercially available authentication and security features.

4. Describe the administration, management and reporting capabilities of available solutions.

5. Describe any technical issues or challenges of implementing available solutions at the transmitter sites.

6. What range of Key Performance Parameters (KPP) would you recommend NWS implement with this upgrade (e.g., jitter, availability, response time, throughput, packet loss, bit error rate (BER), etc.)?

7. Describe any simulation, emulation, testing, and/or deployments that have been conducted on or using the proposed available solution.

8. Describe available solution’s capabilities to integrate with existing NWS management tools (e.g., ArcSight and HP OpenView.) Describe any other standard and optional management capabilities of the recommended solution.

9. Provide a life-cycle cost estimate for the recommended solution. Identify the cost drivers.

Include the initial (non-recurring costs), recurring costs, and recommended staffing required to operate and manage the recommended solution. Project cost estimates through Government Fiscal Year 2020.

10. Describe any third-party hardware, software, and services required to support the avaiable solution.

11. Describe your past efforts, if any, to accredit the recommended solution (or one like it) and provide its ability to be accredited.

12. Describe the recommended solution’s compliance with and conformance to FIPS 140-2 and Common Criteria profiles (ISO/IEC15408) Evaluation Assurance Level-2 (EAL-2) or higher.

13. Provide one or more references describing installations of a size and complexity comparable to your recommended available solution.

14. Identify available support options for maintaining current software revisions of the system components and describe how the components are upgraded.

15. Provide the available equipment’s power requirements, EMI concerns and space requirements.

5.0 SUBMISSION INSTRUCTIONS

5.1 Vendor Identification

Responses shall include the (1) business name, address, and DUNS number; (2) name of company representative and their business title with contact information; (3) contract vehicles available that would be available to the Government for the procurement of the product and service, to include General Service Administration (GSA) Federal Supply Schedules (FSS), or any other Government Agency contract vehicle.

5.2 Responding to this RFI

Vendors are asked to recommend components, preferably commercial-off-the-shelf (COTS) or government-off-the-shelf (GOTS), that will be used to deliver the upgraded network and M&C capability. Advice and commentary should be provided on, but not limited to, the recommended solution and the information requested in Section 4.

5.3 Format

The responses shall be in a white paper format, no longer than fifteen (15) pages in length, and submitted in .pdf format. Address the capability questions posed in Section 4 above, and add one

(1) appendix that provides a typical implementation schedule.

Responses shall be submitted to Kolby.Harold@noaa.gov, and are due no later than December 30, 2015 at 1:00PM ET.

Proprietary information and trade secrets, if any, must be clearly marked on all materials. All information received that is marked Proprietary will be handled accordingly. Please be advised that all submissions become Government property and will not be returned. The Government shall not be held liable for any damages incurred if proprietary information is not properly identified.

5.4 Technical Points of Contact

Program Manager: Giao Pham Phone : 301-427-9816 (O), 202-384-3886 (M) E-Mail: Giao.Pham@noaa.gov

Alternate Program Manager: Steve Golston Phone : 301-427-9700 (O), 240-338-1206 (M) E-Mail: Steven.Golston@noaa.gov mailto:Kolby.Harold@noaa.gov mailto:Giao.Pham@noaa.gov mailto:Steven.Golston@noaa.gov

APPENDIX A – REFERENCES

1. Details of monitor & control functionality for each of the transmitter brands is available in Interface Control Documents (ICDs) and other documents held by the Government, and will be provided upon request.

2. NOAA Weather Radio (NWR) All Hazards Specific Area Message Encoding (SAME) http://www.nws.noaa.gov/directives/sym/pd01017012curr.pdf

3. FCC Part 11.31 EAS http://www.gpo.gov/fdsys/pkg/CFR-2009-title47-vol1/pdf/CFR- 2009-title47-vol1-part11.pdf http://www.nws.noaa.gov/directives/sym/pd01017012curr.pdf http://www.gpo.gov/fdsys/pkg/CFR-2009-title47-vol1/pdf/CFR-2009-title47-vol1-part11.pdf http://www.gpo.gov/fdsys/pkg/CFR-2009-title47-vol1/pdf/CFR-2009-title47-vol1-part11.pdf

APPENDIX B – ACRONYMS

Acronym Description ADC Analog-to-Digital Conversion/Converter AGO Acquisition and Grants Office (NOAA) AoA Analysis of Alternatives AWIPS Advanced Weather Interactive Processing System BER Bit Error Rate BMH Broadcast Message Handler CAC Common Access Card CEA Consumer Electronics Association CEC Continental Electronic Corporation CONUS Contiguous United States COOP Continuity of Operations COTS Commercial Off-the-Shelf CRS Console Replacement System CWA County Warning Area DAC Digital-to-Analog Converter DS0 Digital Signal level-0 (64 kbps) DST Dissemination Systems Team EAL Evaluation Assurance Level EAS Emergency Alert System EDT Eastern Daylight Time EIA Electronic Industries Alliance FAR Federal Acquisition Regulation FCAPS Fault, Configuration, Accounting, Performance, and Security FCC Federal Communications Commission FEA Federal Enterprise Architecture FIPS Federal Information Processing Standard FISMA Federal Information Security Management Act FSS Federal Supply Schedules FTP File Transfer Protocol GOTS Government Off-the-Shelf GSA General Services Administration HP Hewlett-Packard IEC International Electrotechnical Commission IP Internet Protocol IPv6 Internet Protocol, Version 6 ISO International Organization for Standards ICD Interface Control Document IT Information Technology ITU International Telecommunication Union kbps kilobits per second (103 bits per second) KPP Key Performance Parameters M&C Monitor & Control MB megabyte (106 bytes) Mbps megabits per second (106 bits per second) MIB Management Information Base MTBF Mean Time Between Failures MTTR Mean Time To Repair NDA Non-Disclosure Agreement NIST National Institute of Standards and Technology NOAA National Oceanic and Atmospheric Administration NWR NOAA Weather Radio All Hazards NWRUP NWR Upgrade Project NWS National Weather Service NWWS NOAA Weather Wire Service OCONUS Off-Continental United States OneNWSNet NWS Wide Area Network POTS Plain Old Telephone System RAMS ROAMS Automated Management System RF Radio Frequency RC&M Remote Control & Monitor RFC River Forecast Center RFI Request for Information RFP Request for Proposal ROAMS Remote Off-Air Monitoring System RSM Remote SAME Monitor SAME Specific Area Message Encoding SCAP Security Content Automation Protocol SNMP Simple Network Management Protocol TCP Transport Control Protocol TCP/IP Transmission Control Protocol/internet protocol suite (CCR 1528) Telco Telephone Company TV Thermal Vacuum UDP User Datagram Protocol UHF Ultra-High Frequency USC United States Code VHF Very High Frequency VPN Virtual Private Network WFO Weather Forecast Office Xmit Transmit

Description
Disclaimer
1.0 INTRODUCTION
2.0 NOAA Weather Radio (NWR) Overview
3.0 NWR Upgrade Project (NWRUP) High-Level Requirements
3.1 Dissemination System Upgrades
3.2 Monitoring and Control System Upgrades
3.3 Environmental Requirements
3.3.1 Non-Transmitter Site (Office Environment) Equipment
3.3.2 Transmitter Site Equipment

3.4 Upgrade Project Considerations

4.0 Requested Information
5.0 SUBMISSION INSTRUCTIONS
5.1 Vendor Identification
5.2 Responding to this RFI
5.3 Format
5.4 Technical Points of Contact
APPENDIX A – REFERENCES
APPENDIX B – ACRONYMS

File details come from the government source that posted it. Updated .