1-19-2-L
MESS AREA
1-18-1-Q
PLAN VIEW, MAIN DECK
SCALE: 1/8" = 1'-0"
GALLEY
1-28-1-Q 1-27-1-A
STORES
1-15-0-L
PASSAGE
WR/WC
1-31-2-L SR (4)
1-24-2-L SR (4)
RECIRC. PUMP
FCSLE DK (OVER)
1-12-1-Q
SHIP'S OFFICE
1-15-1-E
WTR HTR &
SR (4)
1-12-2-L
1-9-0-Q
LAUNDRY
LC VESSEL
UP
1-9-2-V
VOID
MED LKR
1-9-1-A
1-7-2-A
CHAIN LOCKER
1-7-1-A
CHAIN LOCKER
EQUIPMENT RM
1-2-0-E
1-57-1-T
ACCESS
UP
BOAT & DECK
1-58-2-A
GEAR LOCKER
AFT SCIENCE LAB
1-43-1-C
FORWARD SCIENCE LAB
1-34-1-C
DN
DN
1-46-2-Q
WORKSHOP
UPS ROOM
1-43-2
PASSAGE
1-61-1-L
DN
COMPUTER CTR
ESD
ESD
MSS
MSSFAN P/S
WTD
F.S. 7
AFFF TANK
M
NO.11
F.S. 6
P
P
GAYLORD GALLEY HOOD
FIRE EXTING'R PULL
F
ESME
ESME
F.S. 8NO. 15
GENERAL ALARM BELL
B/C2 CARBON DIOXIDE PORTABLE
FIRE AXE
SLEDGE HAMMER
FIREMAN'S OUTFIT WITH
SELF-CONTAINED BREATHING APP.
REMOTE RELEASE STATION, HALON
1-1/2" HOSE, 50', WITH NOZZLE
FOAM HOSE REEL
SMOKE DETECTOR
HEAT DETECTOR
FIRST AID KIT
STRETCHER/LITTER
INTERNATIONAL SHORE CONNECTION
LIFE-RING WITH LIGHT
FIRE DETECTION REMOTE ANNUNCIATOR
FIRE CONTROL STATION
EMERGENCY SHUTDOWN
MISSION SYSTEM SHUTDOWN
EMERGENCY STOP, MAIN ENGINE
MANUAL FIRE ALARM PULL
REACH ROD SHUTOFFS, FUEL OIL VALVES
EYEWASH STATION
M MOTOR OPERATED VALVE
LINE THROWING DEVICE
FIRE MAIN PRESSURE INDICATOR
FIRE DAMPER (MACHINERY)
VENTILATOR CLOSURE
PLAN VIEW, HOLD
SCALE: 1/8" = 1'-0"
WTD
EXIT VL
EXIT VL UP
SCALE: 1/8" = 1'-0"
6"1' 2' 4'3' 8'
WTD
SLIDING
SHELL @ MAIN DECK
SHELL @ 5'-9" WL
FWD
STEERING GEAR RM (S)
ESCAPE VL
2-83-1-E
VOID
2-80-1-V
STEERING
2-83-0-E
GEAR RM (C)
2-79-0-T
PASSAGEWAY
2-71-5-F
TANK NO. 2 (S)
FUEL OIL
2-71-3-T
PASSAGEWAY
UP
UP
2-71-1-W
TANK (S)
POTABLE WTR
2-71-2-W
TANK (P)
POTABLE WTR
STEERING GEAR RM (P)
2-83-2-E
VOID
2-80-2-V
TANK NO. 2 (P)
2-71-6-F
2-71-4-A
STOREROOM
FUEL OIL
ENGINE RM ESCAPE/EXH TRUNK (P)
1.5-57-2-T
FUEL OIL DAY TK (S)
2-46-3-F
PASSAGE
1.5-29-0-T
MULTI-PURPOSE ROOM
2-48-1-Q
ELECTRICAL
2-46-1-C
ENGRS OPR STA
FO TK NO.1 (S)
SSDG #1
2-51-1-F
ROOM
SSDG #2
MAIN ENGINE
2-46-0-E
ENGINE ROOM
SSDG #3
CREW'S LOUNGE
1.5-36-1-L
ESCAPE VL
FRZ
1.5-29-2-A
PARTS RM
SPARE
2-48-2-A
FO TK NO.1 (P)
2-51-2-F
ENGINE ROOM EXHAUST TRUNK (P)
ENGINEERS STORES
2-60-2-A
1.5-57-2-T
FUEL OIL DAY TK (P)
2-46-2-F
F.O. TANK NO.3 (S)
REFER
STORES
1.5-21-1-A
MSD
WTD
SLIDING
UP
COMPRESSORS
REFR
SEWAGE TANK
1.5-21-0-W
2-12-1-F
MOTOR COMPT
2-12-0-E
BOW THRUSTER
FOREPEAK VOID
2-2-0-V
2-12-2-F
F.O. TANK NO.3 (P)
EXERCISE ROOM
1.5-21-2-L
2-18-0-V
VOID
L VESSELC
PUBLIC ADDRESS
AUXILIARY MACHINERY
2-63-0-E
ROOM
FWD
WTD
1-35-2-C
DRY CHEMICAL PORTABLE
STORES
1-20-1-A
5 SPARES
GENERAL ALARM BELL WITH LIGHT
LEGEND
DIVE COMPRESSOR
& 12 HP AIR CYL.
APPARATUS (EEBD)
EMERGENCY ESCAPE BREATHING
FIRE PUMP, 300 GPM
EMERGENCY FIRE PUMP, 300 GPM
VL
VL
SPACE PROTECTED BY FOAM
SPACE PROTECTED BY HALON
H
F
H
FIRE PLAN
Fire
Plan
FIRE & SMOKE DETECTION PANEL
G EMERGENCY GENERATOR
GENERAL ALARM, PUSH BUTTON/SWITCH
EMERGENCY BATTERY
NO. 10
NO. 9
NO. 6
NO. 7
NO. 8
NO. 21
NO. 18, 19 & 20
1515 15
NO. 17
NO. 16
NO. 14
NO. 13
NO. 12
FE
Fire
Plan
50 GALLON
P
CO2
H
M
M
FCS
FWD HYDRAULIC
PCO2
CO2
CO2
P
CO2
P
A A
H
CO2
P
CO2 CO2
P P
CO2
P
P
CO2
F
FIXED AFFF TANK
F
F
W
W
W
W
F
CO2
NO. 22
CO2
CO2
PRIMARY ESCAPE ROUTE
FLAMMABLE
LIQUID
LOCKER
FLAMMABLE
LIQUID
LOCKER
ESCAPE
HATCH
FIRE DAMPERS
ESCAPE
HATCH
ESCAPE
HATCH
IMMERSION SUIT
A
B
7 6 5
C
D
8 7 6 5
OFFICE OF MARINE & AVIATION OPERATIONS
NOAA SHIP
D
SCALE:
SIZE
NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION
#CONTRACT
4 3
DR
NOAA APPROVAL
WRP
WRP
TAR-SSI-021-(02)
50-ABNA-0-00032
DWN
CHK
CHK
JEK
DSGN
8-4-02
8-4-02
8-4-02
8-4-02
Seaworthy Systems, Inc.
TEL: (860) 767-9061
ESSEX, CT 06426
P.O. BOX 965
MARINE ENGINEERS
NAVAL ARCHITECTS
NF-555-001
FIRE AND SAFETY PLAN
NF555001F
NOAA DRAWING NUMBER
OYLJ5
CAD FILENAMEAS SHOWN
CAGE CODE
I
1SHT 2OF
REV
A
NANCY FOSTER
B
4 3 2
C
REVISIONS
D
LABELED BRIDGE WING SMOKE CANISTERS
UPDATE IMO SYMBOLS, RELOCATE EQUIP.
DESCRIPTION
UPDATE IMO SYMBOLS, GENERAL REVISIONS
SHT
C 1-2
2A
B 1-2
REV
VAR. -
115-C,D
VAR. -
ITEMZONE
5/30/03
1/31/03
3/4/03
DATE
RJH
RJH
RJH
APPD
WASTE OIL TANK
(BELOW DK PLATES)
CO2
MACHINERY (EXTERIOR)
M
M
M
M
A
A A
A
A
FIRE DAMPER (ACCOMODATION)
ESCAPE
HATCH
ESCAPE
HATCH
H
PORT FO DAY TANK
DIRTY OIL TK
PORT FO DAY TK
FO TK NO. 1 PORT
FO TK NO. 1 STBD
STBD DAY TK SERVICE
STBD DAY TK SUCTION
FO TK NO. 1 STBD
ESCAPE HATCH
& BOW THRSTR
ACCESS
L
L
L
L
L
FE
DEFIBRILLLATOR
DIRTY OIL FO PUMP
FUEL OIL PUMP
FO PUMPS, REMOTE SHUT DOWN
NO. 23
CO2
REMOTE CONTROL FOR WATERTIGHT
DOORS OR FIRE DOORS
WT
WT
EMERGENCY POWER PANELEP
EMERGENCY LIGHTING PANELEL
EL
PANEL EL102
2-63-9-A
BOTTLES, HALON or CO
SPARE EXTINGUISHING
H
BATTERY, HALON
FIXED EXTINGUISHING
H
LIFEJACKET
REMOTE VENTILATION SHUTDOWN
GENERAL REVISIONS FROM SHIP'S CREW CHECKD 1-2 VAR. - 7/21/03 RJH
(4) (4)
(4) (4)
(4) (4)
F.S. 9
W
REVISIONS (cont'd)
ADDED TWO EEBD FR 25 PSGWY
DESCRIPTIONSHT
1E
REV
14C
ITEMZONE
12/17
DATE APPD
ADDED FS #9, 2-79-0-T27A '03
ADDED JOINER DOOR, FR 15, MAIN DECK33C
VL EMERGENCY ESCAPE
VL EMERGENCY ESCAPE
3C
4C
6C
4B
5A
8B
1F
ADDED EEBD AT EOS
CHANGED SMOKE TO HEAT DET, GALLEY
RELOCATED FLAME LOCKER
LABELED VL AS ESCAPE VL
DELETED LADDER RUNGS STEERING COMPT
2/9 '04
ADDED ESCAPE VL PORT SIDE OF LAUNDRY
CO2
SPACE PROTECTED BY CO2
CO2
CO2
BOW THRUSTER
ROOM
REVISIONS, cont'd SHT 2
CO2
50# CO2
RELEASE STATION
FEFE
M
M
VL EMERGENCY ESCAPE
90 85 80 75 70
65 54 44 40 35 30 25 20 15 10 5 0
90 85 80 75 70 6065 55 50 45 40
30 15 10 5 0
SHT 1
File details come from the government source that posted it. Updated .