NF-555-001-1I-SHT_1_Fire_Plan.pdf

PDF 517 KB Posted

Attached to
Drydock Repairs to NOAA Ship NANCY FOSTER
Solicitation number
EA-133M-15-RP-0119
Issued by

About this file

Drawing

View the file

Other files

File Type Posted
SF_30 _Amend_0003.pdf PDF
SF_30 _Amend_0002.pdf PDF
NOAA_Ship_Nancy_Foster_Tank_Sounding_Tables_GSSP_2005_9-4-2009.pdf PDF
Drawing_NF-100-004_Starboard_Exhaust_Stack_Mod_Rev_03-19-2015.pdf PDF
Drawing_601130_Zinc_Anode_Installation.pdf PDF
NF-533-002_Potable_Water_Piping_System.pdf PDF
NFFY16DD_Repair_Index_and_Spec_Package_with_Forms_Rev_08-28-2015_for_Amend_0002.pdf PDF
Std_Spec_573-1C_Testing_of_Davits_and_Weight_Handling_Gear.pdf PDF
Std_Spec_533-1_Potable_Water_Tank_Disinfection.pdf PDF
Std_Spec_300-1_Overhaul_of_Electrical_Rotating_Machinery.pdf PDF
Std_Spec_510-1B_HVAC_Cleaning.pdf PDF
Std_Spec_581-1A_Inspection___Preservation_of_Ground_Tackle.pdf PDF
Technical_Manual_NF-243-01_Shaft_Seal_TM.pdf PDF
Std_Spec_000-2C_Temporary_Services_at_Contractor_Facilities.pdf PDF
Std_Spec_631-2D_Coating_Systems_for_Steel_Surfaces.pdf PDF
Photo_100_2119_DESH-5_Winch_as_installed_aboard_M2_08-17-2007.pdf PDF
Std_Spec_583-1b_General_Requirements_for_Liferaft_Inspections.pdf PDF
Section_B..pdf PDF
Std_Spec_635-1_Thermal_Insulation_for_Piping.pdf PDF
NF-555-6500975_Halon_1501_Fire_Suppression_System.pdf PDF
Std_Spec_997-1A_Drydocking_and_Routine_Drydock_Work.pdf PDF
Section_G..pdf PDF
Technical_Namual_for_GoodCrane_Model_40KSC10000_Crane.pdf PDF
Photo_100_2120_DESH-5_Winch_as_installed_aboard_M2_08-17-2007.pdf PDF
Std_Spec_505-1B_Valve_Overhaul_and_Test.pdf PDF
Std_Spec_631-3B_Underwater_Ablative_Coating_System.PDF PDF
Std_Spec_573-2_Overhaul___Repair_of_Hydraulic_Cylinders.pdf PDF
Drawing_101-6500833_Model_E_ structural .pdf PDF
Std_Spec_505-2_Hydrostatic_Pressure_Tests.pdf PDF
NF-561-001_Rev._C. _Steering_System_Installations.pdf PDF
NF_512-003 _HVAC_System.pdf PDF
Std_Spec_635-2_Thermal_Insulation_for_Compartments.pdf PDF
Technical_Manual_NF-561-001_Rev._C_Steering_System_Installation.pdf PDF
SF_30 _Amend_0001.pdf PDF
NF-555-001-2I-SHT_2_Fire_Plan.pdf PDF
Photo_100_2118_DESH-5_Winch_as_installed_aboard_M2_08-17-2007.pdf PDF
Std_Spec_602-1_Weight_Test_Data_Plates.pdf PDF
Std_Spec_100-1A_ABS_Load_Line_Survey.pdf PDF
Std_Spec_240-1_Propulsion_Shafts_and_Propellers.pdf PDF
Drawing_101-6500837_Aft_Foc'sle_House_Module_(Module_J).pdf PDF
NFFY16DD_Repair_Index_and_Spec_Package_with_Forms_Rev_08-19-2015.pdf PDF
Std_Spec_300-3_General_Requirements_for_Electrcial_Electronic_Items.pdf PDF
NF-555-6500976_AFFF_System.pdf PDF
NF-243-001_Shafting_Arrangement_and_Details.pdf PDF
NF-461-002___EM710_-_Multibeam_Echo_Sounder__Installation_85767775.pdf PDF
NF-424-001___DSN-450_-_Doppler_Speed_Log_Installation_85770548.pdf PDF
Desh5_Winch_Addition_and_Operations.pdf PDF
Technical_Manual_YTT-243-034_Propeller_Removal-Installation_System.pdf PDF
Drawing_214-MS_Watertight_Spring_Assist_Raised_Hatch_with_Dogs.pdf PDF
Drawing_C34842_DESH-5_Turntable_-_19000OL_CERT.pdf PDF
Show 40 more

Latest 50 of 84 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1-19-2-L

MESS AREA

1-18-1-Q

PLAN VIEW, MAIN DECK

SCALE: 1/8" = 1'-0"

GALLEY

1-28-1-Q 1-27-1-A

STORES

1-15-0-L

PASSAGE

WR/WC

1-31-2-L SR (4)

1-24-2-L SR (4)

RECIRC. PUMP

FCSLE DK (OVER)

1-12-1-Q

SHIP'S OFFICE

1-15-1-E

WTR HTR &

SR (4)

1-12-2-L

1-9-0-Q

LAUNDRY

LC VESSEL

UP

1-9-2-V

VOID

MED LKR

1-9-1-A

1-7-2-A

CHAIN LOCKER

1-7-1-A

CHAIN LOCKER

EQUIPMENT RM

1-2-0-E

1-57-1-T

ACCESS

UP

BOAT & DECK

1-58-2-A

GEAR LOCKER

AFT SCIENCE LAB

1-43-1-C

FORWARD SCIENCE LAB

1-34-1-C

DN

DN

1-46-2-Q

WORKSHOP

UPS ROOM

1-43-2

PASSAGE

1-61-1-L

DN

COMPUTER CTR

ESD

ESD

MSS

MSSFAN P/S

WTD

F.S. 7

AFFF TANK

M

NO.11

F.S. 6

P

P

GAYLORD GALLEY HOOD

FIRE EXTING'R PULL

F

ESME

ESME

F.S. 8NO. 15

GENERAL ALARM BELL

B/C2 CARBON DIOXIDE PORTABLE

FIRE AXE

SLEDGE HAMMER

FIREMAN'S OUTFIT WITH

SELF-CONTAINED BREATHING APP.

REMOTE RELEASE STATION, HALON

1-1/2" HOSE, 50', WITH NOZZLE

FOAM HOSE REEL

SMOKE DETECTOR

HEAT DETECTOR

FIRST AID KIT

STRETCHER/LITTER

INTERNATIONAL SHORE CONNECTION

LIFE-RING WITH LIGHT

FIRE DETECTION REMOTE ANNUNCIATOR

FIRE CONTROL STATION

EMERGENCY SHUTDOWN

MISSION SYSTEM SHUTDOWN

EMERGENCY STOP, MAIN ENGINE

MANUAL FIRE ALARM PULL

REACH ROD SHUTOFFS, FUEL OIL VALVES

EYEWASH STATION

M MOTOR OPERATED VALVE

LINE THROWING DEVICE

FIRE MAIN PRESSURE INDICATOR

FIRE DAMPER (MACHINERY)

VENTILATOR CLOSURE

PLAN VIEW, HOLD

SCALE: 1/8" = 1'-0"

WTD

EXIT VL

EXIT VL UP

SCALE: 1/8" = 1'-0"

6"1' 2' 4'3' 8'

WTD

SLIDING

SHELL @ MAIN DECK

SHELL @ 5'-9" WL

FWD

STEERING GEAR RM (S)

ESCAPE VL

2-83-1-E

VOID

2-80-1-V

STEERING

2-83-0-E

GEAR RM (C)

2-79-0-T

PASSAGEWAY

2-71-5-F

TANK NO. 2 (S)

FUEL OIL

2-71-3-T

PASSAGEWAY

UP

UP

2-71-1-W

TANK (S)

POTABLE WTR

2-71-2-W

TANK (P)

POTABLE WTR

STEERING GEAR RM (P)

2-83-2-E

VOID

2-80-2-V

TANK NO. 2 (P)

2-71-6-F

2-71-4-A

STOREROOM

FUEL OIL

ENGINE RM ESCAPE/EXH TRUNK (P)

1.5-57-2-T

FUEL OIL DAY TK (S)

2-46-3-F

PASSAGE

1.5-29-0-T

MULTI-PURPOSE ROOM

2-48-1-Q

ELECTRICAL

2-46-1-C

ENGRS OPR STA

FO TK NO.1 (S)

SSDG #1

2-51-1-F

ROOM

SSDG #2

MAIN ENGINE

2-46-0-E

ENGINE ROOM

SSDG #3

CREW'S LOUNGE

1.5-36-1-L

ESCAPE VL

FRZ

1.5-29-2-A

PARTS RM

SPARE

2-48-2-A

FO TK NO.1 (P)

2-51-2-F

ENGINE ROOM EXHAUST TRUNK (P)

ENGINEERS STORES

2-60-2-A

1.5-57-2-T

FUEL OIL DAY TK (P)

2-46-2-F

F.O. TANK NO.3 (S)

REFER

STORES

1.5-21-1-A

MSD

WTD

SLIDING

UP

COMPRESSORS

REFR

SEWAGE TANK

1.5-21-0-W

2-12-1-F

MOTOR COMPT

2-12-0-E

BOW THRUSTER

FOREPEAK VOID

2-2-0-V

2-12-2-F

F.O. TANK NO.3 (P)

EXERCISE ROOM

1.5-21-2-L

2-18-0-V

VOID

L VESSELC

PUBLIC ADDRESS

AUXILIARY MACHINERY

2-63-0-E

ROOM

FWD

WTD

1-35-2-C

DRY CHEMICAL PORTABLE

STORES

1-20-1-A

5 SPARES

GENERAL ALARM BELL WITH LIGHT

LEGEND

DIVE COMPRESSOR

& 12 HP AIR CYL.

APPARATUS (EEBD)

EMERGENCY ESCAPE BREATHING

FIRE PUMP, 300 GPM

EMERGENCY FIRE PUMP, 300 GPM

VL

VL

SPACE PROTECTED BY FOAM

SPACE PROTECTED BY HALON

H

F

H

FIRE PLAN

Fire

Plan

FIRE & SMOKE DETECTION PANEL

G EMERGENCY GENERATOR

GENERAL ALARM, PUSH BUTTON/SWITCH

EMERGENCY BATTERY

NO. 10

NO. 9

NO. 6

NO. 7

NO. 8

NO. 21

NO. 18, 19 & 20

1515 15

NO. 17

NO. 16

NO. 14

NO. 13

NO. 12

FE

Fire

Plan

50 GALLON

P

CO2

H

M

M

FCS

FWD HYDRAULIC

PCO2

CO2

CO2

P

CO2

P

A A

H

CO2

P

CO2 CO2

P P

CO2

P

P

CO2

F

FIXED AFFF TANK

F

F

W

W

W

W

F

CO2

NO. 22

CO2

CO2

PRIMARY ESCAPE ROUTE

FLAMMABLE

LIQUID

LOCKER

FLAMMABLE

LIQUID

LOCKER

ESCAPE

HATCH

FIRE DAMPERS

ESCAPE

HATCH

ESCAPE

HATCH

IMMERSION SUIT

A

B

7 6 5

C

D

8 7 6 5

OFFICE OF MARINE & AVIATION OPERATIONS

NOAA SHIP

D

SCALE:

SIZE

NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION

#CONTRACT

4 3

DR

NOAA APPROVAL

WRP

WRP

TAR-SSI-021-(02)

50-ABNA-0-00032

DWN

CHK

CHK

JEK

DSGN

8-4-02

8-4-02

8-4-02

8-4-02

Seaworthy Systems, Inc.

TEL: (860) 767-9061

ESSEX, CT 06426

P.O. BOX 965

MARINE ENGINEERS

NAVAL ARCHITECTS

NF-555-001

FIRE AND SAFETY PLAN

NF555001F

NOAA DRAWING NUMBER

OYLJ5

CAD FILENAMEAS SHOWN

CAGE CODE

I

1SHT 2OF

REV

A

NANCY FOSTER

B

4 3 2

C

REVISIONS

D

LABELED BRIDGE WING SMOKE CANISTERS

UPDATE IMO SYMBOLS, RELOCATE EQUIP.

DESCRIPTION

UPDATE IMO SYMBOLS, GENERAL REVISIONS

SHT

C 1-2

2A

B 1-2

REV

VAR. -

115-C,D

VAR. -

ITEMZONE

5/30/03

1/31/03

3/4/03

DATE

RJH

RJH

RJH

APPD

WASTE OIL TANK

(BELOW DK PLATES)

CO2

MACHINERY (EXTERIOR)

M

M

M

M

A

A A

A

A

FIRE DAMPER (ACCOMODATION)

ESCAPE

HATCH

ESCAPE

HATCH

H

PORT FO DAY TANK

DIRTY OIL TK

PORT FO DAY TK

FO TK NO. 1 PORT

FO TK NO. 1 STBD

STBD DAY TK SERVICE

STBD DAY TK SUCTION

FO TK NO. 1 STBD

ESCAPE HATCH

& BOW THRSTR

ACCESS

L

L

L

L

L

FE

DEFIBRILLLATOR

DIRTY OIL FO PUMP

FUEL OIL PUMP

FO PUMPS, REMOTE SHUT DOWN

NO. 23

CO2

REMOTE CONTROL FOR WATERTIGHT

DOORS OR FIRE DOORS

WT

WT

EMERGENCY POWER PANELEP

EMERGENCY LIGHTING PANELEL

EL

PANEL EL102

2-63-9-A

BOTTLES, HALON or CO

SPARE EXTINGUISHING

H

BATTERY, HALON

FIXED EXTINGUISHING

H

LIFEJACKET

REMOTE VENTILATION SHUTDOWN

GENERAL REVISIONS FROM SHIP'S CREW CHECKD 1-2 VAR. - 7/21/03 RJH

(4) (4)

(4) (4)

(4) (4)

F.S. 9

W

REVISIONS (cont'd)

ADDED TWO EEBD FR 25 PSGWY

DESCRIPTIONSHT

1E

REV

14C

ITEMZONE

12/17

DATE APPD

ADDED FS #9, 2-79-0-T27A '03

ADDED JOINER DOOR, FR 15, MAIN DECK33C

VL EMERGENCY ESCAPE

VL EMERGENCY ESCAPE

3C

4C

6C

4B

5A

8B

1F

ADDED EEBD AT EOS

CHANGED SMOKE TO HEAT DET, GALLEY

RELOCATED FLAME LOCKER

LABELED VL AS ESCAPE VL

DELETED LADDER RUNGS STEERING COMPT

2/9 '04

ADDED ESCAPE VL PORT SIDE OF LAUNDRY

CO2

SPACE PROTECTED BY CO2

CO2

CO2

BOW THRUSTER

ROOM

REVISIONS, cont'd SHT 2

CO2

50# CO2

RELEASE STATION

FEFE

M

M

VL EMERGENCY ESCAPE

90 85 80 75 70

65 54 44 40 35 30 25 20 15 10 5 0

90 85 80 75 70 6065 55 50 45 40

30 15 10 5 0

SHT 1

File details come from the government source that posted it. Updated .