Text version
Shipping Container – Qty 2
Container type ISO CONTAINER WITH ONE FULL SIDE OPENING (DOUBLE BIFOLD SWING DOOR)
AND DOUBLE DOORS ON ONE END
Material 14 GAUGE STEEL External Dimension (LxWxH) 20’ x 8' x 9.5’ Minimum Internal dimension with Insulation (LxWxH): 229.69" x 90.25" x 102.52"
Minimum side door dimension (WxH): 229.69" x 100"
Minimum end door dimension (WxH): 89.57" x 97"
Flooring
THE CONTAINER FLOOR SHALL BE SKINNED WITH 0.5" FLAT STEEL PLATING (ASTM
A588 GRADE A) AND MUST BE WELDED/BOLTED TO THE BASE FRAME OF THE
CONTAINER. THE TOP OF THE FLOOR AND BOTTOM OF THE DOOR FRAMES SHALL
BE FLUSH WITHIN 0.13 INCHES
Insulation
A. CEILING AND WALL CONSTRUCTION OF THE CONTAINER SHALL INCLUDE AN
INSULATON BARRIER INSULATING FROM THE OUTER WALL TO 0.5" BEYOND
INNER WALL SURFACE.
B. INSULATION MATERIAL SHALL BE SUITABLE FOR USE IN MARINE ENVIRONMENT
AND SHALL BE FABRICATED FROM
MATERIAL THAT DO NOT GIVE OFF TOXIC FUMES OR SUPPORT COMBUSTION.
C. MINIMUM R FACTOR OF R-4.
D. INSULATION SHOULD INCLUDE 0.06" 5052 ALUMINUM RIGID INTERIOR
BARRIER.
E. IT IS NOT REQUIRED TO INSULATE INNER SURFACES OF PORTAL (DOOR
PERIMETER) AND INSULATION SHOULD BE
TERMINATED AT EDGES, AROUND FITTINGS AND FIXTURES.
Finish/Paint
INTERIOR STRUCTURE FINISH DETAILS: UNLESS OTHERWISE SPECIFIED, FOLLOW
ALL COATINGS MANUFACTURER'S COATING APPLICATION INSTRUCTIONS.
>SURFACE PREPARATION: ABRASIVE BLAST TO SSPC-SP10 (NEAR WHITE METAL).
>PRIMER COAT: ONE COAT OF MIL-PRF-23236D, TYPE V, CLASS 7, GRADE C. APPLY
PRIMER COAT TO BARE SURFACES ONLY IAW MANUFACTURER INSTRUCTIONS.
>STRIPE COAT: ONE COAT OF MIL-PRF -23236D, TYPE V, CLASS 7, GRADE C. APPLY
ON OUTSIDE CORNERS, EDGES, CREVICES, WELDS, AND OTHER IRREGULAR
SURFACES IAW MANUFACTURER INSTRUCTIONS.
>TOP COAT: ONE COAT OF MIL-PRF-24635F, TYPE V, CLASS 2, GRADE B,
COMPOSITION 2, COLOR WHITE (FED. STD. 595, COLOR CHIP NO. 27886.) APPLY
TO SURFACES PREPARED WITH PRIMER COAT IAW MANUFACTURER
INSTRUCTION.
EXTERIOR STRUCTURE FINISH DETAILS: UNLESS OTHERWISE SPECIFIED, FOLLOW
ALL COATINGS MANUFACTURER'S COATING APPLICATION INSTRUCTIONS.
>SURFACE PREPARATION: ABRASIVE BLAST TO SSPC-SP10 (NEAR WHITE METAL).
>PRIMER COAT: APPLY MIL-PRF-23236D, TYPE V, CLASS 7, GRADE C, IAW
MANUFACTURER INSTRUCTIONS. APPLY PRIMER AS NECESSARY TO ATTAIN A
TOTAL PRIMER DRY FILM THICKNESS (DFT) OF 12-16 MILS.
>TOP COAT: APPLY MIL-PRF-24635F, TYPE V, CLASS 2, GRADE B, COMPOSITION 2,
COLOR HAZE GRAY (FED. STD. 595, COLOR CHIP NO. 26270), IAW MANUFACTURER
INSTRUCTIONS. APPLY TOP COAT AS NECESSARY TO ATTAIN A TOTAL EXTERIOR
FINISH DFT OF 16-23 MILS.
Forklift Pockets SHALL BE IAW ISO 1496:1998.
Corner Fittings SHALL BE IAW ISO 1161:1984.
Shipping Container – Qty 2
Access Control
A. ALL LOCKING HARDWARE SHALL BE WITHIN EXTERIOR DIMENSION
BOUNDARIES SET FORTH BY ISO 1496:1998.
B. LOCKING HARDWARE REQUIREMENTS CAN BE MET BY USE OF A HIGH SECURITY
LOCK CONFIRMING TO MILITARY SPECIFICATION MIL-P-43607 (LATEST SERIES), OR
AS OTHERWISE LISTED IN APPENDIX D OF OPNAVINST 5530.13C.
C. THE LOCKS SHALL NOT REDUCE THE EFFECTIVE OPEN DOOR CLEARANCE FOR
LOADING/UNLOADING OPERATIONS.
D. CONTAINERS SHALL INCLUDE ANTI-TAMPERING MEASURES TO EFFECTIVELY
PROTECT CRITICAL TECHNOLOGIES
Door gaskets ALL CONTAINER OPENINGS SHALL BE SEALED WITH A CONTINUOUS GASKET IAW
ISO 1496:1998.
Transportation Certifications
CONTAINERS SHALL MEET TRANSPORTATION CERTIFICATIONS FOR ROAD, RAIL,
AND SEA IAW:
A. AMERICAN BUREAU OF SHIPPING (ABS) RULES FOR CERTIFICATION OF CARGO
CONTAINERS
B. INTERNATIONAL CONVENTION FOR SAFE CONTAINERS (CSC)