This document is a Source Control Drawing for a Power Supply used in the Weather Surveillance Radar - 1988 Doppler (WSR-88D) system, manufactured by Aegis Power Systems. The power supply (-201 configuration) is a single-phase, 120VAC unit with multiple voltage outputs: 6.5VDC at 4.5A, 15VDC at 5A, and 48VDC at 12A, with a total nominal input power of 907W. Key specifications include an efficiency greater than 70% at 50% load, a startup time of 1.5 seconds, and internal forced air cooling with field-replaceable fans.
The drawing provides detailed environmental and performance requirements, including operating temperature range of -40°C to +49°C, compliance with MIL-STD-461 electromagnetic interference standards, and a Mean Time Between Failure (MTBF) of at least 166,000 hours. The unit has specific connector configurations, temperature warning systems, and is designed for use in the National Weather Service's NEXRAD (Next Generation Weather Radar) system. The document includes multiple configuration options for the power supply, fan tray assembly, fan upgrade kit, and associated harness, with precise dimensional and technical specifications for each component.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CAR 1352.209-74.docx | DOCX document | |
| Power Supply with Fan ASN R400-2A9PS1 NRC142082-25-0478 FBO Posting.docx | DOCX document | |
| A-5_Instructions_for_Shipping (1)02.28.24-08-20-25.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CAGE CODE 0WY55 DWG NO. 2210091 SHEET 1 OF 10
SIZE CAGE CODE DWG NO. REV
A 0WY55 2210091 A
SCALE: NONE SHEET 1 OF 10
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ON:
WSR-88D RADAR OPERATIONS CENTER
1313 HALLEY CIRCLE
NORMAN, OKLAHOMA 73069-8480
MILLIMETERS
1 PL
2 PL
ANGLES 2
INCHES
2 PL .02
3 PL .010
NOMENCLATURE
POWER SUPPLY, SINGLE PHASE, 60Hz, 120VAC, TRIPLE
OUTPUT, AME
APPROVALS
DWN AWB 140906 RMT JBM 140906
CHK BOB 140906 DOC MAK 140906
ENGR GSS 140906 CM
QA ROC
DISTRIBUTION STATEMENT A: APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED.
SOURCE CONTROL DRAWING
APPLICATION
NHA USED ON LTR DATE ECO ECP REVISION DESCRIPTION APVD
BS-2000-400-
WSR-88D
A 140906
ECP 0628 ECO
A06192
INITIAL RELEASE
REPLACES BS-2000-460-900
GSS
PRINTED BY:IM, NEXRAD (nexradim) DO NOT SCALE DRAWINGDATE PRINTED:07/11/2025 07:43:57 AM PDT
NUMBER:2210091PROPERTY OF THE U.S. GOVERNMENT (NATIONAL WEATHER SERVICE)STATUS:Production
CAGE CODE 0WY55 DWG NO. 2210091 SHEET 2 OF 10
SCALE: NONE SHEET 2 OF 10
1. SCOPE
1.1. THE COMPONENT WILL BE REFERRED TO HEREIN AS THE UNIT. THE UNIT IS A COMPONENT OF THE OF THE
WEATHER SURVEILLANCE RADAR - 1988 DOPPLER (WSR-88D) SYSTEM.
1.2. IDENTIFICATION OF ANY SUGGESTED SOURCE OF SUPPLY (MANUFACTURER) CONTAINED IN THIS
SPECIFICATION IS NOT TO BE CONSTRUED AS A GUARANTEE OF PRESENT OR FUTURE AVAILABILITY AS A
SOURCE OF SUPPLY FOR THE ITEM(S).
1.3. THE USE OF A DIFFERENT PART FROM A LISTED SUGGESTED SOURCE OF SUPPLY OR A PART FROM A NON-
LISTED SUGGESTED SOURCE OF SUPPLY WHICH MEETS THE SPECIFICATIONS HEREIN SHALL OCCUR ONLY
AFTER REVIEW/CONCURRENCE AND A FIRST ARTICLE QUALIFICATION BY THE WSR-88D RADAR
OPERATIONS CENTER (ROC) AS WELL AS ACCEPTANCE INSPECTION BY THE NATIONAL RECONDITIONING
CENTER (NRC).
1.4. APPLICABLE DOCUMENTS
1.4.1. PRECEDENCE OF DOCUMENTS: IN THE EVENT OF A CONFLICT BETWEEN THE REFERENCED DOCUMENT(S) AND
THIS DRAWING, THE CONTENTS OF THIS DRAWING TAKES PRECEDENCE AS THE GOVERNING DOCUMENT.
1.4.2. LIST OF DOCUMENTS
1.5. ALL GIVEN DIMENSIONS, UNLESS OTHERWISE SPECIFIED, ARE IN INCHES. TOLERANCES ON 2 PLACES ±. 02
AND ON 3 PLACES ± .010. WEIGHT, UNLESS OTHERWISE SPECIFIED, IS GIVEN IN POUNDS.
TABLE I - LIST OF DOCUMENTS
NUMBER TITLE/DESCRIPTION
MIL-STD-461 ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS,
REQUIREMENTS FOR EQUIPMENT
MIL-STD-810 ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND
LABORATORY TEST
MIL-DTL-5541, CLASS 3 CHEMICAL CONVERSION COATINGS ON ALUMINUM AND
ALUMINUM ALLOYS
MIL-DTL-81706 CHEMICAL CONVERSION COATINGS ON ALUMINUM AND
ALUMINUM ALLOYS
CAGE CODE 0WY55 DWG NO. 2210091 SHEET 3 OF 10
A 0WY55 2210091 A
SCALE: NONE SHEET 3 OF 10
2. REQUIREMENTS
2.1. PERFORMANCE:
2.1.1. POWER SUPPLY (-201)
2.1.1.1. INPUT VOLTAGE: 120VAC ±10%, 57-63Hz.
2.1.1.2. INPUT POWER FACTOR: .95 NOMINAL.
2.1.1.3. INPUT LINE CURRENT: 8.3 AMPS NOMINAL.
2.1.1.4. EFFICIENCY: ˃70% AT 50% LOAD.
2.1.1.5. INPUT POWER: 907w NOMINAL (955VA).
2.1.1.6. STARTUP TIME: 1.5 SECONDS.
2.1.1.7. OUTPUTS: 6.5VDC, 15VDC AND 48VDC. SEE TABLE A.
TABLE A
VOLTAGE OUTPUTS
NOA301 V1 V2 V3
VOLTAGE +6.5Vdc +15Vdc +48Vdc
CURRENT 4.5A 5A 12A
POWER 30W 75W 600W
RIPPLE 150V Pk-Pk 150V Pk-Pk 500V Pk-Pk
2.1.1.8. OUTPUT CURRENT LIMIT: SHORT CIRCUIT PROTECTED, AUTOMATIC RECOVERY.
2.1.1.9. REGULATION:
2.1.1.9.1. TEMPERATURE: ±0.01% PER DEGREE C.
2.1.1.9.2. LINE/LOAD: ±1%.
2.1.1.9.3. SET POINT: ±0.5%.
2.1.1.10. OUTPUT RIPPLE: 1.5% OF Vout Pk-Pk (20Mhz BW). SEE TABLE A.
2.1.1.11. CURRENT LIMIT: SHORT CIRCUIT PROTECTED, AUTO RESTART.
2.1.1.12. TEMPERATURE WARNINGS:
2.1.1.12.1. WARNING: POWER SUPPLY PLATE TEMPERATURE IS AT 75°C OR HIGHER. NO ALARM SHALL BE INDICATED
FOR TEMPERATURES BELOW 65°C. TOLERANCE ±5°C.
2.1.1.12.2. CRITICAL: POWER SUPPLY PLATE TEMPERATURE IS AT 78°C OR HIGHER. NO ALARM SHALL BE INDICATED
FOR TEMPERATURES BELOW 75°C. TOLERANCE ±5°C.
2.1.1.12.3. THE WARNING OUTPUT SIGNALS SHALL BE OPEN COLLECTOR CAPABLE OF SINKING 20Ma MINIMUM TO THE
POWER SUPPLY DC/COMMON GROUND. WHEN THE FAULT CONDITION EXISTS, THE OPEN COLLECTOR CIRCUIT SHALL BEN ENABLED “ON”, PULLING THE WARNING SIGNAL TO GROUND. WHEN NO FAULT CONDITION EXISTS, THE OPEN COLLECTOR CIRCUIT SHALL BE DISABLED “OFF”, AN IN A HIGH IMPEDANCE
STATE.
CAGE CODE 0WY55 DWG NO. 2210091 SHEET 4 OF 10
SCALE: NONE SHEET 4 OF 10
2.1.1.13. CONNECTORS: THE UNIT SHALL HAVE ONE (1) AC INPUT CONNECTOR PER MS3122E12-3P AND ONE (1) DC
OUTPUT CONNECTOR PER MS3122E16-8S. SEE TABLE B.
TABLE B
INPUT AND OUTPUT CONNECTIONS
REF DES CONNECTOR TYPE PINOUTS FUNCTION
J1 MS3122E12-3P
A 120VAC LINE
B 120VAC NEUTRAL
C CHASSIS GROUND
J2 MS3122E16-8S
A,B +48VDC
C +6.5VDC
D +15VDC
E TEMP WARNING (OPEN COLLECTOR)
F CRITICAL WARNING (OPEN COLLECTOR)
G,H GROUND
2.1.1.14. COOLING: INTERNAL FORCED AIR FANS, FIELD REPLACEABLE (-202).
2.2. MATERIAL FINISH: CLEAR CHEMICAL FILM TREATMENT, RoHS COMPLIANT, MIL-C-5541, CLASS 3, IAW MIL-
DTL-81706, TYPE II, CLASS 3, PAINT BLACK, POWDER COAT, WHITE TEXT.
2.3. MARKINGS: THE UNIT SHALL BE MARKED “J1” AND “120VAC INPUT” FOR THE MS3122E12-3P CONNECTOR
AND “J” AND “DC OUTPUT” FOR THE MS3122E16-8S CONNECTOR.
2.4. VIEWS: SEE SECTION 6
2.5. RELIABILITY: THE UNIT MTBF - NO LESS THAN 166,000 HOURS (WITHOUT FAN TRAY).
2.6. TRANSPORTABILITY: THE UNIT MUST BE CAPABLE OF BEING TRANSPORTED VIA COMMON SURFACE, AIR, OR SEA CARRIER IN ITS PACKED-FOR-SHIPMENT CONFIGURATION.
2.7. ITEM DIMENSIONS: 6.75 MAX INCHES IN HEIGHT, 12.5 MAX INCHES IN LENGTH AND 9.0 MAX INCHES IN
WIDTH.
2.8. NAMEPLATES, MARKINGS: THE UNIT MUST BE UNIQUELY MARKED WITH A MINIMUM OF PRODUCT NAME
AND VENDOR.
2.9. SAFETY: THE UNIT MUST COMPLY WITH UL 60950 COMMERCIAL SAFETY STANDARD.
3. ENVIRONMENTAL SPECIFICATIONS:
3.1.1. ELECTROMAGNETIC RADIATION AND EMISSIONS: THIS UNIT MUST COMPLY WITH FCC EMI CLASS A.
3.1.2. OPERATING TEMPERATURE: -40ºC (-40ºF) TO +49ºC (120ºF)
3.1.3. NON-OPERATING TEMPERATURE: -62ºC (-80ºF) TO +60ºC (140ºF)
3.1.4. OPERATING HUMIDITY: 15% TO 95%
3.1.5. NON-OPERATING HUMIDITY: 15% TO 95%
3.1.6. ALTITUDE: UP TO 3300 METERS ABOVE MEAN SEA LEVEL
4. QUALITY ASSURANCE:
CAGE CODE 0WY55 DWG NO. 2210091 SHEET 5 OF 10
SCALE: NONE SHEET 5 OF 10
4.1. GOVERNMENT INSPECTION REQUIREMENTS: THE QUALITY CONTROL OR INSPECTION SYSTEM AND
MANUFACTURING PROCESSES OF SUPPLIERS DELIVERING PRODUCT TO MEET THE REQUIREMENTS OF THIS SPECIFICATION ARE SUBJECT TO REVIEW, VERIFICATION, AND ANALYSIS BY AUTHORIZED GOVERNMENT REPRESENTATIVES. GOVERNMENT INSPECTION OR RELEASE OF PRODUCT PRIOR TO SHIPMENT IS NOT
REQUIRED UNLESS THE SUPPLIER IS OTHERWISE NOTIFIED.
4.2. EVIDENCE OF QUALITY CONFORMANCE: EVIDENCE OF CONFORMANCE WITH THE REQUIREMENTS OF THIS
SPECIFICATION AND REFERENCED STANDARDS SHALL BE SUBMITTED WITH EACH UNIT. EVIDENCE OF
QUALITY CONFORMANCE SHALL BE ONE OR MORE OF THE FOLLOWING FORMS:
1. ACCEPTABLE, SUPPLIER-FURNISHED INSPECTION OR TEST DATA
2. ACCEPTABLE, TRACEABLE, SUPPLIER STATEMENTS OF QUALITY
3. ACCEPTABLE, TRACEABLE, SUPPLIER STATEMENTS OF QUALITY
4. ACCEPTABLE SUPPLIER CERTIFICATIONS (DISTRIBUTORS)
5. SUGGESTED SOURCE(S) OF SUPPLY (MANUFACTURER(S)):
AEGIS POWER SYSTEMS (CAGE CODE 06ES8)
MURPHY, NORTH CAROLINA
PART NUMBER: SEE TABLE II
TABLE II
DASH
NO.
ITEM
MFR.
PART NO.
FIGURE
NO.
NOTE
NO.
POWER SUPPLY WITH FAN TRAY
ASSEMBLY AND FAN UPGRADE KIT
NOA301 1 1
202 FAN TRAY ASSEMBLY NOA301FT 2 2
203 FAN UPGRADE KIT NOA301FANKIT 3 3
204 HARNESS NOA301H01 4 4
NOTES:
1. THE –201 CONFIGURATION IS USED FOR FIELD REPLACEMENT, IT IS THE POWER SUPPLY WITH THE FAN TRAY
ASSEMBLY (-202) AND FAN UPGRADE KIT (-203).
2. THE –202 CONFIGURATION IS FOR FIELD REPLACEMENT OF THE FAN ONLY.
3. THE -203 CONFIGURATION IS FOR FAN UPGRADE ONLY, IT CHANGES THE FOUR SMALL FANS FOR ONE LARGE FAN
AND IS THE REPLACEMENT FOR AEGIS FAN TRAY ASSEMBLY PART NUMBER BA2809FT USED ON AEGIS POWER SUPPLY PART NUMBER BA2809. IT INCLUDES THE FAN TRAY ASSEMBLY (-202) AND HARNESS (-204). IT ALSO INCLUDES 1 PIECE OF SHRINK TUBING FOR COVERING THE HARNESS (-204) WHERE IT ATTACHES TO THE POWER SUPPLY AND FOUR SCREWS (#6-32 X .186 LONG) FOR MOUNTING THE TRAY TO THE POWER SUPPLY.
4. THE -204 CONFIGURATION IS ONLY USED FOR POWER SUPPLIES UPGRADED WITH THE FAN UPGRADE KIT (-204). IT WILL NOT BE SUPPLIED WITH THE NOA301 POWER SUPPLY ASSEMBLY (-201), THAT CONFIGURATION WILL HAVE
THE HARNESS HARDWIRED INTO THE POWER SUPPLY.
CAGE CODE 0WY55 DWG NO. 2210091 SHEET 6 OF 10
SCALE: NONE SHEET 6 OF 10
6. FIGURES AND DIAGRAMS
FIGURE 1
CAGE CODE 0WY55 DWG NO. 2210091 SHEET 7 OF 10
A 0WY55 2210091 A
SCALE: NONE SHEET 7 OF 10
POWER SUPPLY WITH FAN TRAY ASSEMBLY
-201 CONFIGURATION
VIEW A-A
ROTATED 90° CW
CAGE CODE 0WY55 DWG NO. 2210091 SHEET 8 OF 10
SCALE: NONE SHEET 8 OF 10
VIEW B-B
ROTATED 90° CCW
CAGE CODE 0WY55 DWG NO. 2210091 SHEET 9 OF 10
SCALE: NONE SHEET 9 OF 10
FIGURE 2
FAN TRAY ASSEMBLY
-202 CONFIGURATION
CAGE CODE 0WY55 DWG NO. 2210091 SHEET 10 OF 10
SCALE: NONE SHEET 10 OF 10
FIGURE 3
FAN
UPGRA
DE KIT
-203 CONFIGURATION
FIGURE 4
HARNESS
-204 CONFIGURATION