About this file
This document is a detailed engineering drawing (DWG) for a Muon Window structural assembly, specifically drawing number DU-1004-9380. The design features multiple I-beams (W14 X 193), cross braces, angle brackets, bolt plates, and liner components fabricated from A572-65 steel. The assembly includes numerous hardware components such as hex head cap screws (HHCS), washers, and nuts in various sizes (primarily 5/8" diameter). The drawing provides multiple sectional views with precise dimensional tolerances, noting a flatness tolerance of 0.59 for the entire inner facing and 0.15 for any 39-inch path. The technical specifications adhere to AISC 303-22 code standards, with specific attention to geometric tolerancing and dimensional precision.
The bill of materials lists 20 unique parts, including 2 long I-beams (137.7 inches), multiple cross braces, angle brackets, bolt plates, and various fasteners. Quantities range from 1 to 830 units per component type. The drawing is marked as proprietary and confidential, with a scale of 1:75 and annotations indicating dimensional measurements in inches. The technical drawing includes detailed section views (A-A, B-B, C-C, D-D) at different scales, providing comprehensive structural and assembly details for manufacturing and construction purposes.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DU-1005-7620 PRISM Frame.PDF | ||
| DU-1004-8765 DUNE-ND Warm Structure.PDF | ||
| BZ-2025-14 Warm Structure RFI.pdf | ||
| DU-1005-8388 Warm Structure Assy.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
137.71in 3497.84mm
326.58in 8295.23mm
AA
C
C2
0.060 A
APPLIES TO ALL BOLT PLATES
16 PLACES
15.86in 402.72mm
15.48in 393.19mm
B
B
SECTION A-A
SCALE 1 : 32
19 15
1567 5 11
A FLATNESS TOLERANCE OF 0.59
APPLIES TO THE ENTIRE
FACE OF THE INNER FACING
A FLATNESS TOLERANCE OF 0.15 APPLIES TO ANY
POSSIBLE 39 IN [1M] PATH ACROSS THE INNER FACING
DD
SECTION B-B
SCALE 1 : 16
6 1
0.15
39.37in 1000.00mm
SECTION D-D
SCALE 1 : 32
11 1010 11117
.75in 19.05mm
.38in
9.53mm
SECTION C-C
SCALE 1 : 32
23/8 3/8
8 LOCATIONS
16 LOCATIONS
DIMENSIONAL TOLERANCES TO MEET AISC 303-22 CODE UNLESS OTHERWISE SPECIFIED1.
MATERIAL: A572-65 STEEL OR APPROVED EQUIVALENT2.
0.59
A
ITEM NO. PART NUMBER NAME QTY.
1 DU-1005-8908 I BEAM W14 X 193, 137.7 LONG 2
2 DU-1005-9590 I BEAM W14 X 193 X 306.88 1
3 DU-1005-8910 I BEAM W14 X 193 X 306.88 1
4 DU-1005-8917 CROSS BRACE VERTICAL, MUON WINDOW 7
5 DU-1005-9051 CROSS BRACE HORIZONTAL 1 MUON
WINDOW 1
6 DU-1005-9539 CROSS BRACE HORIZONTAL 2 MUON
WINDOW 6
7 DU-1005-9052 CROSS BRACE HORIZONTAL 3 MUON
WINDOW 1
8 DU-1005-9053 ANGLE BRACKET MUON WINDOW 7
9 DU-1005-9065 ANGLE 2 MUON WINDOW 14
10 DU-1005-9497 BOLT PLATE - MUON WINDOW 16
11 DU-1005-9521 DU-1005-9521.SLDPRT 8
12 DU-1005-9546 INNER LINER - MUON WINDOW 1
13 DU-1005-9570 OUTER LINER - MUON WINDOW 1
14 DU-1005-8323 REGULAR WASHER 5/8 830
15 DU-1005-9600 HHCS 5/8-18 X .75 294
16 DU-1005-8324 HEX NUT 5/8-11 160
17 DU-1005-8319 HHCS 5/8-11 X 2.5 96
18 DU-1005-9720 HHCS 5/8-11 X 3.0 65
19 DU-1005-9740 HHCS 5/8-11 X 1.5 108
20 DU-1006-0425 HHCS 5/8-18 X 1.5 108A A
B B
C C
D D
A.4
DO NOT SCALE DRAWING
DU-1004-9380
SHEET 1 OF 1
2024 SE 09SAH
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:75 WEIGHT: N/A
REVDWG. NO.
D
SIZE
TITLE:
NAME DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL NA
ANGULAR: MACH 1 BEND
TWO PLACE DECIMAL .02
THREE PLACE DECIMAL .005
APPLICATION
USED ONNEXT ASSY
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
| Sheet1 |
| Drawing View1 |
| Section View A-A |
| Drawing View6 |
| Drawing View7 |
| Section View B-B |
| Drawing View12 |
| Section View D-D |
| Section View C-C |