Sea_valves_REQUIRING_waster_spool_pieces.docx
DOCX document 33 KB Posted
- Solicitation number
- DTMA92Q1500016
About this file
Sea valves REQUIRING waster spool pieces
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Manually Operated Skin Valves
| Location |
| Type |
| Waster Piece required |
| Size / Pressure |
| Bolts Per Flange / Bonnet |
| Steaming-Out For Fire Pump Sea Chest Main Sea Scoop |
| 123-Stbd |
| Globe |
| YES |
| 3 / 150 |
| 4 / 4 |
| Flushing Line To Main Sea Scoop |
| 123-Stbd |
| Globe |
| YES |
| 4 / 150 |
| 8 / 8 |
| Bilge/Ballast Pump/Gen'l Serv Pump Sea Suct. |
| 129-Port |
| Gate |
| YES |
| 8 / 150 |
| 8 / 12 |
| Bilge Oily Ballast & F.O. Transfer Pump Sea Suction |
| 129-Stbd |
| Gate |
| YES |
| 6 / 150 |
| 8 / 8 |
| Salt Water Service System Ovbd. Disch. |
| 129-Port |
| Gate |
| YES |
| 6 / 150 |
| 8 / 6 |
| Main & Aux. Circ. Pumps & Bilge Ballast & F.O. Trans. Pump High Sea Chest Vent |
| 129-Stbd |
| Gate |
| YES |
| 5 / 150 |
| 8 / 6 |
| Bilge & Ballast & Gen. Service Pumps Aux. Mach. Serv. Pump Dist. Plant & Fire Main Pump Sea Chest Vent |
| 129-Port |
| Globe |
| YES |
| 5 / 150 |
| 4 / 4 |
| Steaming-Out For Fire Pump Sea Chest Aux. High Sea Chest |
| 129-Port |
| Globe |
| YES |
| 1 / 150 |
| 4 / 4 |
| Fire-Pump Suction Aux. High Sea Chest |
| 129-Port |
| Gate |
| YES |
| 8 / 150 |
| 8 / 10 |
| Boiler-Blowdown Overboard Discharge |
| 129-Stbd |
| Globe |
| YES |
| 2 / 600 |
| 8 / 6 |
| Dist. Feed Pump Sea Suction Aux. High Sea Chest |
| 129-Port |
| Gate |
| YES |
| 6 / 150 |
| 8 / 6 |
| Aux. Mach. Sea Water Service Pump (Standby) High Sea Chest Suction |
| 129-Port |
| Gate |
| YES |
| 6 / 150 |
| 8 / 8 |
| Steaming-Out For Fire Pump Sea Chest Main & Aux. Circ. High Sea Chest |
| 131-Stbd |
| Globe |
| YES |
| 1 / 150 |
| 4 / 4 |
| Steaming-Out For Fire Pump Sea Chest Circ. Low Sea Chest |
| 131-Stbd |
| Globe |
| YES |
| 1 / 150 |
| 4 / 4 |
| Main Circ. Pump Low Sea Chest Vent |
| 131-Stbd |
| Gate |
| YES |
| 5 / 150 |
| 8 / 4 |
| Main Cond. Overboard Discharge Self Venting |
| 132-Port |
| Gate |
| YES |
| 10 / 150 |
| 12 / 12 |
| L.O. Cooler Overboard Discharge |
| 134-Port |
| Gate |
| YES |
| 6 / 150 |
| 8 / 8 |
| Bilge Oily Ballast & F.O. Transfer Pump Ovbd. Disch. |
| 135-Stbd |
| Globe |
| YES |
| 5 / 150 |
| 8 / 10 |
| Contaminated Steam Gen. Blowdown Ovbd. Disch. |
| 135-Port |
| Globe |
| YES |
| 2 / 150 |
| 4 / 4 |
| Aux. Circ Pumps Low Sea Chest Vent |
| 136-Stbd |
| Gate |
| YES |
| 3 / 5 |
| 4 / 6 |
| Dist. Brine Pump Overboard Discharge |
| 136-Port |
| Globe |
| YES |
| 4 / 150 |
| 4 / 6 |
| Steaming-Out For Fire Pump Sea Chest Aux. Low Sea Chest |
| 137-Stbd |
| Globe |
| YES |
| 1 / 150 |
| 4 / 4 |
| Bilge/Ballast Pump Gen. Service Ovbd. Disch. |
| 137-Port |
| Globe |
| YES |
| 5 / 150 |
| 8 / 10 |
| Fire Pump Sea Chest Vent |
| 188-Stbd |
| Globe |
| YES |
| 2 / 150 |
| 4 / 4 |
| Steaming-Out For Fire Pump Sea Chest |
| 188-Stbd |
| Globe |
| YES |
| 1 / 600 |
| 4 / 4 |
| Motor Operated Sea Valves |
| Location |
| Type |
| Size / Pressure |
| Bolts Per Flange / Bonnet |
| SSTG # 2 Aux. Circ. Pump High Sea Suction |
| 130-Stbd |
| Gate |
| YES |
| 10 / 150 |
| 12 / 12 |
| Main Condenser Circ. Pump High-Sea Suction (Motor operator removed) |
| 131-Stbd |
| Gate |
| YES |
| 20 / 150 |
| 20 / 16 |
| SSTG # 1 Aux. Circ Pump High Sea Suction |
| 132-Stbd |
| Gate |
| YES |
| 10 / 150 |
| 12 / 12 |
| SSTG # 2 Condenser Overboard Discharge |
| 135-Stbd |
| Gate |
| YES |
| 8 / 150 |
| 8 / 12 |
| SSTG # 2 Aux. Circ. Pump Low Sea Suction |
| 136-Stbd |
| Gate |
| YES |
| 10 / 150 |
| 12 / 12 |
| SSTG # 1 Condenser Overboard Discharge |
| 136-Stbd |
| Gate |
| YES |
| 8 / 150 |
| 8 / 12 |
| SSTG # 1 Aux. Circ. Pump Low Sea Suction |
| 137-Stbd |
| Gate |
| YES |
| 10 / 150 |
| 12 / 12 |
| Fire-Pump #1 Sea Suction (Shaft Alley) |
| 188-Stbd |
| Gate |
| YES |
| 5 / 150 |
| 8 / 6 |
| Emergency Fire Pump Discharge Check (non-return valve) |
| 121-STBD |
| Globe |
| YES |
| 4/150 |
| 8/8 |
File details come from the government source that posted it. Updated .