About this file

ATTACHMENT B - CALIBRATION CERTIFICATION REQUIREMENTS

View the file

Other files for this federal contract opportunity

Other files attached to FHWA EFLHD CALIBRATION SERVICES, newest first.
File Type Posted
CSC_Work_Att(A)a_FY16.xls XLS spreadsheet
RFQ_NO._DTFH7116Q00009.pdf PDF
SOW.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Attachment "B"
Checklist
Page 1 of 1
Calibration Certification Requirements
Certificate Must Contain:Comment/Details/Additional Info
1A Title such as "Report and Certifiace of Calibration"Per AASHTO R-18 Table Rquirements, use the applicable
or "Report and Certificate of Check"title.
or "Report and Certificate of Standardization"Check"
2Name and address of calibration service provider's firmsuch as A2LA, etc.
Logo of ISO 17025 accreditation body
3Location of where the calibration/standardization/check took placeEFLHD Lab room number or Provider's Lab
and in which EFLHD Lab section the equipment belongsSoils & Aggregate Section, Concrete Section, Asphalt Binder Section,
Asphalt Mixture Section
4Unique identification of the calibration certificate (such as serialsuch as sieves Set #1, 2, etc.
number, file number, etc.) The identification goes on each page
of the certificate.
Pagination of the certificate (1 of 2, 2 of 2, etc.)
5Name and address of the client (EFLHD)Federal Highway Adminisdtration
Do not use a person's nameEastern Federal Lands Highway Division
Materials Labaoratory
1827 Jack Delozier Drive
Sevierville, TN 37876
6Description and identification of the item being calibratedName of equipment, and S/N
include model number alsoA list containing all identifying numbers will be provided to
you for easy reference
7Date of performance of the calibration or verification;Information on past dates and frequencies will be provided to you
and date of last C/S/C and date of next C/S/C; and
C/S/C frequency or interval; and notations ofSuch as;
recommended action, if anyRepair___ Replace____ None____ Other____
8Calibration/Standardization/Check results with appropriate
units of measurement
9Documented procedures used in performing the C/S/C work;
Identify the procedure used to perform theIf the AASHTO or ASTM test procedure contains a calibration
calibration/standardization/check, orprocedure, you must use and refer to that procedure number.
a brief, clear description of how the calibration was performedIf there is a Provider's in-house procedure used, you must refer
to that specific procedure number or describe it on the cert.
10The conditions (e.g. environment) under which thestate the environmental conditions if they are required
calibrations, etc. were madeby the calibration procedure
11Statement of the Measurement Uncertainty
12Evidence that the measurements are traceable, includinginclude description and serial numbers, NIST numbers, etc.
uniquely identified calibration equipment/tools used
13Name, function, and signature of metrologist authorizing the
certificate
14Statement specifying that the certificate shall not
be reproduced except in full, and not without written
approval of the EFLHD Materials Laboratory