This document is a Pre-Demolition Hazardous Building Materials Survey Report prepared by Arcadis U.S., Inc. for the Massachusetts Department of Correction, specifically focused on the MCI Framingham Brewster Building #16 and Modular Unit Building #15 located at 99 Loring Drive in Framingham, Massachusetts. The survey, conducted on February 11-12, 2025, and revised on September 11, 2025, comprehensively assessed the presence of hazardous building materials including asbestos-containing materials (ACMs), RCRA-8 metals in paint, polychlorinated biphenyls (PCBs), and regulated materials and universal waste. The survey's primary objective was to identify and catalog potentially hazardous materials to assist in preparing an abatement scope of work for removal, transportation, and disposal prior to demolition activities.
The survey findings revealed one confirmed asbestos-containing material (ACM) in the Modular Unit Building #15 - adhesive beneath the rubber roofing membrane containing 15% chrysotile asbestos. Additionally, detectable concentrations of RCRA-8 metals were found in paint samples from both the Brewster Building #16 and Modular Unit Building #15, including various painted surfaces such as metal doors, wall panels, and exterior walls. The report also identified potentially regulated materials and universal waste, including X-ray machines, fluorescent bulbs/ballasts, equipment with refrigerants, cleaning solvents, televisions, emergency exit signs, fire extinguishers, and hot water tanks. Recommendations include proper removal and disposal of identified hazardous materials by qualified contractors in compliance with federal, state, and local regulations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Intent Form~33.doc | DOC document | |
| Prevailing Wage Statement of Compliance~85.pdf | ||
| Where to get plans and specs~58.docx | DOCX document | |
| WageSchedule_20250821174756.pdf | ||
| Bid Package~39.doc | DOC document | |
| Site Visit Attendees DRM 2024-103.pdf | ||
| DRM 2024-103 Framingham Brewster Modular Building Demo Addendum No 1.pdf | ||
| schedule-for-participation-by-mwbe-construction~2.pdf | ||
| Prevailing Wage Payroll Report Form~87.pdf | ||
| Bidder Checklist~75.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Massachusetts Department of Correction
PRE-DEMOLITION HAZARDOUS
BUILDING MATERIALS SURVEY
REPORT
MCI Framingham The Mods & Brewster Building Demolition Project 99 Loring Drive Framingham, Massachusetts 01702
February 27, 2025 Revised on September 11, 2025
PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY REPORT
arcadis.com
PRE-DEMOLITION
HAZARDOUS BUILDING
MATERIALS SURVEY REPORT
The Mods & Brewster Building
Demolition Project
MCI Framingham
99 Loring Drive
Framingham, Massachusetts 01702
Prepared for:
Mr. Kenneth Pinarreta
Department of Correction
Division of Resource Management
50 Maple Street, Suite 3
Milford, Massachusetts 01757
Prepared by:
Arcadis U.S., Inc.
One Federal Street
Suite 3800
Boston, Massachusetts 02110
Phone: 617.778.8212
Our Ref.:
30267781
Date:
February 27, 2025
Revised on September 11, 2025
This document is intended only for the use of the individual or entity for which it was prepared and may contain information that is privileged, confidential and exempt from disclosure under applicable law. Any dissemination, distribution or copying of this document is strictly prohibited.
Survey Performed By:
John A. Monaco
The Commonwealth of Massachusetts Department of
Labor Standards Licensed Asbestos Inspector
(AI072774)
Report Reviewed By:
Gregory Donovan
Certified Project Manager i
CONTENTS
1 Introduction
2 Survey Methodology
2.1 Asbestos Survey Approach
2.2 RCRA-8 Paint Survey Approach
2.3 Polychlorinated Biphenyls Survey Approach
2.4 Regulated Materials and Universal Waste Survey Approach
3 Analytical Methods
3.1 Asbestos
3.2 RCRA-8 Metals in Paint
3.3 Polychlorinated Biphenyls
4 Findings
4.1 Asbestos
4.2 RCRA-8 Metals in Paint
4.3 Polychlorinated Biphenyls
4.4 Regulated Materials and Universal Waste
5 Recommendations
5.1 Asbestos
5.2 RCRA-8 Metals in Paint
5.3 Polychlorinated Biphenyls
5.4 Regulated Materials and Universal Waste
6 Survey Limitations ii
TABLES
Table 1 Homogeneous Areas Summary – Brewster Building #16
Table 2 Homogenous Areas Summary – Modular Unit Building #15
Table 3 RCRA-8 Metals in Paint Summary – Brewster Building #16
Table 4 RCRA-8 Metals in Paint Summary – Modular Unit Building #15
Table 5 Polychlorinated Biphenyls Summary – Brewster Building #16
Table 6 Polychlorinated Biphenyls Summary – Modular Unit Building #15
Table 7 Regulated Materials and Universal Waste Inventory – Brewster Building #16
Table 8 Regulated Materials and Universal Waste Inventory – Modular Unit Building #15
FIGURES
Figure 1 Brewster Building #16 1st Floor Sample Locations
Figure 2 Brewster Building #16 2nd Floor Sample Locations
Figure 3 Modular Building #15 Sample Locations
APPENDICES
Appendix A Asbestos Accreditations
Appendix B Laboratory Reports – Asbestos
Appendix C Laboratory Reports – RCRA-8 Metals
Appendix D Laboratory Reports – Polychlorinated Biphenyls
Appendix E Photograph Logs
1 INTRODUCTION
Arcadis U.S., Inc. (Arcadis) conducted a Pre-Demolition Hazardous Building Materials (HBM) Survey
(survey) of the MCI Framingham Brewster Building #16 and Modular Unit Building #15 located at 99 Loring
Drive in Framingham, Massachusetts (site).
The objective of the survey was to ascertain the general presence, quantity, and location of asbestos-containing materials (ACMs), Resource Conservation and Recovery Act (RCRA) 8 metals containing paint, polychlorinated biphenyls (PCBs), and potentially regulated material and universal waste at the site.
The results of the HBM survey will assist in the preparation of an abatement scope of work for the removal, transportation, and disposal of HBMs that may be required prior to demolition activities.
The survey was conducted on February 11 - 12, 2025 Mr. John A. Monaco and September 11, 2025 by Mr.
Gregory Donovan of Arcadis. A copy of their asbestos accreditations is provided in Appendix A.
2 SURVEY METHODOLOGY
2.1 Asbestos Survey Approach
Arcadis conducted the asbestos survey for compliance with the National Emissions Standards for
Hazardous Air Pollutants (NESHAPs), the Massachusetts Department of Environmental Protection 310
CMR 7.15, and the Massachusetts Department of Labor Standards 454 CMR 28.00.
This was accomplished by initially conducting a visual inspection of the buildings, then collecting samples of suspect ACM based on these observations. Arcadis conducted the asbestos survey in general accordance with ASTM International (ASTM) E2356 Standard Practice for Comprehensive Building
Asbestos Surveys. ASTM E2356 meets the applicable requirements of current United States
Environmental Protection Agency (USEPA) NESHAP Standard 40 Code of Federal Regulations (CFR) 61, Subpart M (Asbestos), USEPA Asbestos Hazard Emergency Response Act (AHERA) 40 CFR 763, Subpart
E, and Occupational Safety and Health Administration (OSHA) asbestos survey and/or sampling regulations.
The survey included an inspection of the buildings providing a general sense of the overall location, type, quantity, and condition of potential ACMs present. It was thorough in that most accessible functional spaces were inspected, and bulk samples taken of suspect materials observed.
The survey included destructive, intrusive, and/or exploratory testing. Destructive sampling is performed to identify materials which are hidden or obstructed. Hidden or obstructed areas include but are not limited to wall cavities, pipe chases, and spaces above fixed ceilings. In addition, our survey included accessing, surveying, and sampling accessible roofing systems and exterior materials of the structures.
The asbestos survey included a visual and physical assessment of each accessible space to locate suspect
ACMs. Suspect materials were divided into "Homogeneous Areas" (HAs) (i.e., building materials that were determined by the inspector to be homogeneous based on their color, texture, and assumed date of installation). A representative number of samples were collected from each HA.
Bulk material samples were collected and assigned their own unique identification number, placed in 4-mil plastic bags, and tightly sealed for transport under a chain-of-custody protocol to EMSL Analytical, Inc.
(EMSL) in Indianapolis, Indiana.
2.2 RCRA-8 Paint Survey Approach
Arcadis conducted a RCRA-8 metals in paint survey of representative interior and exterior surfaces for compliance with the USEPA RCRA (Standard 40 CFR 240-280) and OSHA Safety and Health Regulations for Construction (Standard 29 CFR 1926).
Suspect RCRA-8 metal-containing paints were identified based upon a visual inspection of painted interior and exterior building components. Paint chip samples were collected and assigned their own unique identification number, placed in 4-mil sealable plastic bags, and tightly sealed for subsequent shipment under a chain of custody protocol to EMSL in Indianapolis, Indiana.
2.3 Polychlorinated Biphenyls Survey Approach
Arcadis conducted a PCB survey of representative interior and exterior suspect PCB-containing bulk product materials (i.e., non-liquid state) for compliance with the Toxic Substances Control Act (TSCA) PCB regulations in 40 CFR, Part 76.
Suspect PCB-containing materials were identified based upon a visual inspection of the buildings at the site. Samples of suspect PCB-containing materials were collected and assigned their own unique identification number, placed in 4-mil sealable plastic bags, and tightly sealed for subsequent shipment under a chain of custody protocol to EMSL in Indianapolis, Indiana.
2.4 Regulated Materials and Universal Waste Survey Approach
Arcadis conducted a regulated materials and universal waste survey for compliance with the RCRA
Universal Waste Rule (UWR) and Subtitle C hazardous waste regulations.
Potentially regulated materials and universal waste was identified visually, and the information was collected in chart format. The information collected included type of material, container type/size, approximate quantity, and location of the material. No testing of regulated materials and universal waste was performed.
3 ANALYTICAL METHODS
3.1 Asbestos
Bulk samples were analyzed for asbestos (reported in percent of type of asbestos) using Polarized Light
Microscopy with Dispersion Staining (PLM/DS) in accordance with the USEPA Method 600/R-93/116.
Percentage estimates of each material's composition are based on the analyst's best visual judgment following PLM/DS analysis, and examination with a stereoscope.
EMSL is a member of the American Industrial Hygiene Association (AIHA), National Voluntary Laboratory
Accreditation Program (NVLAP). Laboratory analytical reports are provided in Appendix B.
3.2 RCRA-8 Metals in Paint
Paint chip samples were analyzed for total metal content (reported in milligrams per kilogram [mg/Kg]) by
Inductively Coupled Plasma (ICP) Atomic Emission Spectrometry in accordance with USEPA Method SW-
846 3050B/6010D, and Mercury by Cold Vapor Atomic Absorption (CVAA) SW-846 7471B. EMSL conformed to QA/QC procedures established by their accreditation manual. Laboratory analytical reports are provided in Appendix C.
3.3 Polychlorinated Biphenyls
Bulk product samples were analyzed for PCBs in accordance with USEPA Method SW-846 8082A with preparation method 3540C Soxhlet Extraction. The method tests each sample for nine of the most common
PCB Aroclors. PCB results were then reported in concentrations in relation to the reporting limit for each sample. Strict QA/QC provisions were adhered to for analysis of all PCB samples. EMSL conformed to its own in-house QA/QC procedures established by their accreditation manual. Laboratory analytical reports are provided in Appendix D.
4 FINDINGS
4.1 Asbestos
Arcadis identified twenty-five (25) HAs, of which forty-eight (48) bulk samples were collected and submitted for analysis. A listing of the identified HAs, including each HA material description, location, sample number, condition, friability, asbestos content, and estimated quantity are presented in Tables 1 and 2.
Approximate sampling locations are shown on Figures 1 through 3.
One (1) HAs have been confirmed to contain asbestos at concentrations above one percent
(Massachusetts Department of Environmental Protection defines ACM as any material containing one percent or more of asbestos).
The following HA has been confirmed to be ACM:
Modular Unit Building #15
HA-7: Adhesive beneath Rubber Roofing Membrane
The remaining bulk samples collected by Arcadis as part of the survey were reported by the laboratory as
“None Detected” for asbestos. Representative photographs are provided in Appendix D.
4.2 RCRA-8 Metals in Paint
Eleven (11) RCRA-8 metals in paint samples were collected and submitted for laboratory analysis. Details regarding the sample description, sample location, analyte, and results are presented in the RCRA-8 Metals in Paint Summary provided in Tables 3 and 4. Approximate sampling locations are shown in Figures 1 and
3.
Detectable concentrations of RCRA-8 metals were detected in the following paint chips collected:
Brewster Building #16
PC-1: Gray Paint on Metal Door in 1st Floor Janitor Closet
PC-2: White Paint on Fiberglass Reinforced Plastic (FRP) Wall Panel in 1st Floor Day Room
PC-3: Brown Paint on Floor in 1st Floor Restroom
PC-4: Red Paint on Exterior Metal Wall
PC-5: Beige Paint on Exterior Wood Wall
Modular Unit Building #15
PC-1: White Paint on Fiberglass Reinforced Plastic (FRP) Wall Panel in Common Area
PC-2: Light Yellow Paint on Gypsum Board Wall in Office
PC-3: Gray Paint on Wood Door Trim in Common Area
PC-4: Yellow Paint on Exterior Plywood
PC-5: White Paint on Gypsum Board Wall in Common Area
PC-6: Gray Speckled Paint on Wood Floor in Inmate Restroom
4.3 Polychlorinated Biphenyls
Four (4) bulk product samples were collected and submitted for laboratory analysis. The bulk product samples collected by Arcadis as part of the survey were reported by the laboratory as “None Detected” or below the laboratory’s limit of detection for PCBs.
Details regarding the sample ID, material description, sample location, reporting limit, and results of the materials sampled are presented in Tables 5 and 6. Approximate sampling locations are shown on Figures
1 and 3.
4.4 Regulated Materials and Universal Waste
Arcadis’ regulated material and universal waste survey identified potentially regulated materials and universal waste at the site. Potentially regulated and universal waste identified included, but is not limited to, X-Ray machines, fluorescent bulbs/ballasts, equipment containing refrigerants, cleaning solvents televisions, emergency exit signs, fire extinguishers, hot water tanks, etc.
Details regarding the material description, container type, container size, approximate quantity, and location of each potentially regulated material and universal waste identified are presented in Tables 7 and 8.
5 RECOMMENDATIONS
5.1 Asbestos
As presented in Tables 1 and 2, and the laboratory data provided in Appendix B, results of the asbestos survey identified one confirmed ACM at the site.
ACMs identified at the site that may be disturbed during demolition activities, must be removed by a qualified asbestos abatement contractor utilizing industry standard work procedures in accordance with all federal, state, and local regulations governing asbestos.
Due to the inability to effectively separate some types of multi-layered ACMs (i.e., rubber roofing membrane with positive adhesive) from non-ACMs, these materials are considered “asbestos-contaminated” for the purposes of removal and should be managed as ACM.
If other suspect materials, not referenced in this survey report, are identified during demolition activities, Arcadis recommends that these materials be considered ACM until they are inspected by an appropriately licensed asbestos inspector and proven otherwise.
Asbestos waste must be disposed of at an asbestos waste receiving facility that is duly permitted by the state and/or local municipality in which it resides.
5.2 RCRA-8 Metals in Paint
As presented in Tables 3 and 4, and the laboratory data provided in Appendix C, the results of the RCRA-
8 metals in paint survey identified detectable concentrations of RCRA-8 metals in samples collected.
Arcadis recommends that the general contractor and any sub-trades be advised of the presence of RCRA-
8 metals in the paint and the requirements for compliance with RCRA Standards (Title 40 CFR 240-280) and OSHA Safety and Health Regulations for Construction (Standard 29 CFR 1926). Compliance with
OSHA is required for any detectable levels of metals in paint that may potentially be disturbed.
Any work that could disturb known or suspect RCRA-8 metal-containing paint should be conducted in a way to minimize and control dust, and the contractor should perform a thorough cleanup.
If other suspect paints, not referenced in this survey report, are identified during construction activities, Arcadis recommends that these materials be managed as RCRA-8 metal-containing paint until they are sampled and proven otherwise.
Arcadis recommends that waste streams containing paint generated during the planned demolition activities be tested via Toxicity Characteristic Leaching Procedure for waste disposal characterization prior to disposal.
5.3 Polychlorinated Biphenyls
As presented in Tables 5 and 6, and the laboratory data provided in Appendix D, detectable levels of PCBs were not identified in the bulk product material sampled at the site.
If other potentially PCB-containing materials that are not referenced in this report are identified during demolition activities, Arcadis recommends that these materials be managed as PCB-containing until they are inspected and proven otherwise.
5.4 Regulated Materials and Universal Waste
As presented in Tables 7 and 8, results of the regulated materials and universal waste survey visually identified potentially regulated materials and universal waste at the site.
Regulated materials and universal waste identified that are not scheduled for reuse and may be disturbed during demolition activities, must be removed and/or recycled prior to demolition. Arcadis recommends the proper removal, transportation, and recycling or disposal of identified regulated materials and universal waste.
Regulated materials identified herein may be regulated under the RCRA Universal Waste Rule and Subtitle
C hazardous waste regulations.
6 SURVEY LIMITATIONS
Arcadis’ survey is subject to the following survey limitations.
Utilities/services, including electric, water, and heat, were assumed to be active in most areas surveyed.
Materials associated with electrical components and energized equipment were not safely accessible and were not sampled.
The survey did not include inspection of confined spaces, crawl spaces, vessels or tanks, underground piping, conduits, building footings, or subsurface soil asbestos contamination, if any.
The findings of the survey are based on conditions observed at the site on the date of the survey.
TABLES
Table 1
Homogeneous Areas Summary
MCI Framingham
Brewster Building #16
99 Loring Drive
Framingham, Massachusetts 01702
HA No. Material Description Material Location Sample
Number Condition Friability
Asbestos
Content
Estimated
Quantity Unit Notes
HA-1 Rubber Flooring Adhesive
1st Floor Day Room, Offices, CO
Office, 2nd Floor Offices, Day
Room
1-1, 1-2 Good Non-Friable NAD 7,710 SF
HA-2
Fiberglass Reinforced Plastic
(FRP) Panel Adhesive Throughout 2-1, 2-2 Good Non-Friable NAD 44,500 SF
HA-3 Gypsum Board Throughout 3-1, 3-2 Good Friable NAD 49,800 SF
HA-4 Rubber Cove Base Adhesive Throughout 4-1, 4-2 Good Non-Friable NAD 1,660 LF
HA-5 12" x 12" Beige Floor Tile
Cells 1-10, Sprinkler Room, Closet, Electrical Room, CO, 2nd
Floor Electrical Room, MSP
Room
5-1, 5-2 Good Non-Friable NAD 6,584 SF
HA-6
Yellow Floor Tile Mastic associated with HA-5
Cells 1-10, Sprinkler Room, Closet, Electrical Room, CO, 2nd
Floor Electrical Room, MSP
Room
6-1, 6-2 Good Non-Friable NAD 6,584 SF
HA-7 12" x 12" Gray Floor Tile 1st Floor Cells 1 and 2 7-1, 7-2 Damaged Non-Friable NAD 400 SF
HA-8
Yellow Floor Tile Mastic associated with HA-7 1st Floor Cells 1 and 2 8-1, 8-2 Good Non-Friable NAD 400 SF
HA-9 Yellow Speckled Epoxy Flooring 2nd Floor Shower, Restroom 9-1, 9-2 Good Non-Friable NAD 700 SF
HA-10 Rubber Stair Tread Adhesive Front and Rear Stairwells 10-1, 10-2 Good Non-Friable NAD 750 SF
Arcadis U.S., Inc.
Table 1
MCI Framingham
Brewster Building #16
99 Loring Drive
Framingham, Massachusetts 01702
HA No. Material Description Material Location Sample
Number Condition Friability
Asbestos
Content
Estimated
Quantity Unit Notes
HA-11
Adhesive associated with Rubber
Roofing Membrane Small Roof 11-1, 11-2 Damaged Non-Friable NAD Not Quantified SF
HA-12
Gray Sealant associated Flashing around HVAC and Roof
Penetrations
Main Roof 12A, 12B Good Non-Friable NAD 275 SF
HA-13
Gray Sealant associated Metal
HVAC Housing Main Roof 13A, 13B Good Non-Friable NAD 15 LF
HA-14
Black Seam Sealant associated with EPDM Roof Membrane Main Roof 14A, 14B Good Non-Friable NAD 8,500 SF
NAD = No Asbestos Detected
SF = Square Foot
Notes:
LF = Linear Foot
ACM = Asbestos-Containing Material.
Assumed ACM = A material determined by the inspector to be suspect ACM and is considered asbestos-containing until laboratory analysis can prove otherwise.
Table 2
MCI Framingham
Modular Unit Building #15
99 Loring Drive
Framingham, Massachusetts 01702
HA No. Material Description Material Location Sample
Number Condition Friability
Asbestos
Content
Estimated
Quantity Unit Notes
HA-1 12" x 12" Beige Floor Tile Throughout 1-1, 1-2 Damaged Non-Friable NAD 4,680 SF
HA-2
Yellow Floor Tile Mastic associated with HA-1 Throughout 2-1, 2-2 Damaged Non-Friable NAD 4,680 SF
HA-3
Adhesive associated with
Fiberglass Reinforced Plastic
(FRP) Panel
Throughout 3-1, 3-2 Good Non-Friable NAD 6,000 SF
HA-4 Gypsum Board Throughout 4-1, 4-2 Good Friable NAD 10,380 SF
HA-5
Joint Compound associated with
HA-4
Throughout 5-1, 5-2 Good Friable NAD 10,380 SF
HA-6 Rubber Cove Base Adhesive Throughout 6-1, 6-2 Good Non-Friable NAD 480 LF
HA-7
Adhesive beneath Rubber
Roofing Membrane Roof 7-1, 7-2 Good Non-Friable 15% Chrysotile 4,800 SF Bottom Layer
HA-8
Yellow Roofing Insulation (Layer
2) Roof 8-1, 8-2 Good Non-Friable NAD 4,800 SF
HA-9 Black Tar Paper (Layer 3) Roof 9-1, 9-2 Good Non-Friable NAD 4,800 SF
Table 2
MCI Framingham
Modular Unit Building #15
99 Loring Drive
Framingham, Massachusetts 01702
HA No. Material Description Material Location Sample
Number Condition Friability
Asbestos
Content
Estimated
Quantity Unit Notes
HA-10
Rubber Roof Adhesive (Top
Layer) Roof 10-1, 10-2 Good Non-Friable NAD 4,800 SF
Notes:
LF = Linear Foot
NAD = No Asbestos Detected
SF = Square Foot
Table 3
RCRA-8 Metals in Paint Summary
MCI Framingham
Brewster Building #16
99 Loring Drive
Framingham, Massachusetts 01702
Sample ID Building Sample Description Sample Location Arsenic Barium Cadmium Chromium Lead Mercury Selenium Silver Units
PC-1
Brewster Building
#16
Gray Paint on Metal
Door 1st Floor Janitor Closet <3.6 4300 0.98 18 3.8 <0.24 <7.1 1.0 mg/Kg
PC-2
Brewster Building
#16
White Paint on
Fiberglass Reinforced
Plastic (FRP) Wall
Panel
1st Floor Day Room <2.8 14 <0.56 <1.4 <2.8 <0.27 <5.6 2.0 mg/Kg
PC-3
Brewster Building
#16 Brown Paint on Floor 1st Floor Restroom 5.7 16 <0.40 70 2.2 <0.23 <4.0 <0.40 mg/Kg
PC-4
Brewster Building
#16
Red Paint on Exterior
Metal Wall Exterior Wall <7.1 330 <1.4 18 45 <0.26 <14 1.9 mg/Kg
PC-5
Brewster Building
#16
Beige Paint on Exterior
Wood Wall Exterior Wall 2.2 37 <0.39 24 2.6 <0.23 <3.9 <0.39 mg/Kg
Acronyms and Abbreviations:
mg/Kg = milligram per kilogram
Table 4
RCRA-8 Metals in Paint Summary
MCI Framingham
Modular Unit Building #15
99 Loring Drive
Framingham, Massachusetts 01702
Sample ID Building Sample Description Sample Location Arsenic Barium Cadmium Chromium Lead Mercury Selenium Silver Units
PC-1
Modular Unit
Building #15
White Paint on
Fiberglass Reinforced
Plastic (FRP) Wall
Panel
Common Area <2.0 1200 <0.40 4.1 12 <0.24 <4.0 <0.40 mg/Kg
PC-2
Modular Unit
Building #15
Light Yellow Paint on
Gypsum Board Wall Office <2.0 99 <0.40 1.8 <2.0 <0.24 <4.0 1.6 mg/Kg
PC-3
Modular Unit
Building #15
Gray Paint on Wood
Door Trim Common Area <2.0 4400 <0.40 2.1 <2.0 <0.23 <4.0 0.48 mg/Kg
PC-4
Modular Unit
Building #15
Yellow Paint on
Exterior Plywood Exterior <2.0 24 <0.40 5.6 8.9 1.1 <4.0 <0.40 mg/Kg
PC-5
Modular Unit
Building #15
White Paint on
Gypsum Board Wall Common Area <2.0 55 <0.39 1.0 <2.0 <0.23 <3.9 0.56 mg/Kg
PC-6
Modular Unit
Building #15
Gray Speckled Paint on Wood Floor Inmate Restroom <2.0 6300 1.1 4.5 12 <0.24 <4.0 <0.40 mg/Kg
Acronyms and Abbreviations:
mg/Kg = milligram per kilogram
Table 5
Polychlorinated Biphenyls Summary
MCI Framingham
Brewster Building #16
99 Loring Drive
Framingham, Massachusetts 01702
Sample ID Description Sample Location Reporting Limit (mg/kg) Results (mg/kg) Notes
PCB-1
Gray Caulking associated with
Wood Trim Exterior Entry 0.86 ND
PCB-2
White Caulking associated with
Metal Trim on Wall 1st Floor Day Room 0.85 ND
Notes:
ND = None Detected above Reporting Limit
Table 6
Polychlorinated Biphenyls Summary
MCI Framingham
Modular Unit Building #15
99 Loring Drive
Framingham, Massachusetts 01702
Sample ID Description Sample Location Reporting Limit (mg/kg) Results (mg/kg) Notes
PCB-1
White Caulking associated with
Restroom Fixtures Inmate Restroom Sink 0.95 ND
PCB-2
Yellow Caulking associated with
Fiberglass Reinforced Plastic (FRP)
Panels
Inmate Showers 0.87 ND
Notes:
ND = None Detected above Reporting Limit
Table 7
Regulated Materials and Universal Waste Inventory
MCI Framingham
Brewster Building #16
99 Loring Drive
Framingham, Massachusetts 01702
Material Container Type Container Size Approximate Quantity Location Notes
Wall Mounted X-Ray Machine Metal Not Determined 1 Brewster Building #16
Fluorescent Bulbs Glass 4 Foot 368 Brewster Building #16
Fluorescent Light Ballasts associated with 4' Fluorescent
Bulbs
Metal Not Determined 184 Brewster Building #16
Small Light Bulbs Glass Not Determined 28 Brewster Building #16
Fire Pull Stations Metal Not Determined 4 Brewster Building #16
Fire Extinguishers Metal Not Determined 4 Brewster Building #16
Emergency Exit Signs Plastic Not Determined 4 Brewster Building #16
Thermostats Glass Not Determined 6 Brewster Building #16
Fire Strobe Lights Glass Not Determined 6 Brewster Building #16
Hot Water Tank Metal Not Determined 1 Brewster Building #16
Rooftop HVAC Units Metal Not Determined 9 Brewster Building #16 Roof
Table 8
Regulated Materials and Universal Waste Inventory
MCI Framingham
Modular Unit Building #15
99 Loring Drive
Framingham, Massachusetts 01702
Material Container Type Container Size Approximate Quantity Location Notes
Wall Mounted X-Ray Machine Metal Not Determined 1 Modular Unit Building #15
Fluorescent Bulbs Glass 4 Foot 144 Modular Unit Building #15
Fluorescent Light Ballasts associated with 4' Fluorescent
Bulbs
Metal Not Determined 72 Modular Unit Building #15
Air Conditioning Unit Metal Not Determined 1 Modular Unit Building #15
Cleaning Solvents Plastic Boxes Not Determined 14 Modular Unit Building #15
Television Metal/Glass 32 Inches 1 Modular Unit Building #15
Emergency Exit Signs Plastic Not Determined 2 Modular Unit Building #15
Fire Extinguishers Metal Not Determined 2 Modular Unit Building #15
Fire Pull Stations Metal Not Determined 1 Modular Unit Building #15
Fire Strobe Lights Glass Not Determined 4 Modular Unit Building #15
Rooftop HVAC Units Metal Not Determined 7 Modular Unit Building #15
Hot Water Tank Metal Not Determined 1 Modular Unit Building #15
FIGURES
MCI Framingham
99 Loring Drive, Framingham, Massachusetts 01702 Brewster Building #16 - 1st Floor Sample Locations
(Locations are Approximate)
Project Number: 30267781
Inspector: John A. Monaco
Date of Inspection: February 12, 2024
Figure 1
Brewster Building #16 - 2nd Floor Sample Locations
(Locations are Approximate)
Project Number: 30267781
Inspector: John A. Monaco
Date of Inspection: February 12, 2024
Figure 2
Modular Unit Building #15 Sample Locations
(Locations are Approximate)
Project Number: 30267781
Inspector: John A. Monaco
Date of Inspection: February 12, 2025
Figure 3
APPENDIX A
Asbestos Accreditations
Inspector Certifications
Inspector John A. Monaco
Certification Asbestos Inspector
Certified By The Commonwealth of Massachusetts Department of Labor Standards
Certification Number AI072774
Expiration Date November 12, 2025
Inspector Certifications
Inspector Gregory Donovan
Certification Asbestos Inspector
Certified By The Commonwealth of Massachusetts Department of Labor Standards
Certification Number AI034702
Expiration Date March 3, 2026
APPENDIX B
Laboratory Reports – Asbestos
EMSL Analytical, Inc.
6340 CastlePlace Dr. Indianapolis, IN 46250
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162501945EMSL Order:
Customer ID: ACAD78J
Customer PO: 30267781.01
Project ID:
Attention: Phone:Greg Donovan (617) 778-8212
Fax:ARCADIS U.S., Inc.
Received Date:25 Braintree Hill Office Park, Suite 200 02/13/2025 10:05 AM
Analysis Date:Braintree, MA 02184 02/14/2025
Collected Date: 02/12/2025
Project: 99 LORING DRIVE FRAMINGHAM, MA BREWSTER - 1 30267781.01
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1-1
162501945-0001
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
DAY ROOM 1ST
FLOOR - RUBBER
FLOORING
ADHESIVE BROWN
SMOOTH FLOOR
HA: 1
1-2
162501945-0002
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
DAY ROOM 2ND
FLOOR - RUBBER
FLOORING
ADHESIVE BROWN
SMOOTH FLOOR
HA: 1
2-1
162501945-0003
None DetectedNon-fibrous (Other)100%Clear
Non-Fibrous
Homogeneous
DAY RM 1ST FLOOR
- FORMICA
PANELING
ADHESIVE YELLOW
ROUGH WALL
HA: 2
2-2
162501945-0004
None DetectedNon-fibrous (Other)100%Clear
Non-Fibrous
Homogeneous
DAY RM 2ND FLOOR
- FORMICA
PANELING
ADHESIVE YELLOW
ROUGH WALL
HA: 2
3-1
162501945-0005
None DetectedGypsum
Non-fibrous (Other)
70%
5%
Cellulose
Glass
25%
<1%
Brown/White
Fibrous
Heterogeneous
DAY RM 1ST FLOOR
- SHEETROCK
WHITE ROUGH
WALL
HA: 3
3-2
162501945-0006
None DetectedGypsum
Non-fibrous (Other)
55%
5%
Cellulose40%Brown/White
Fibrous
Heterogeneous
CELL #6, 2ND
FLOOR -
SHEETROCK WHITE
ROUGH WALL
HA: 3
4-1
162501945-0007
None DetectedNon-fibrous (Other)100%Brown/Tan
Non-Fibrous
Homogeneous
1ST FL OFFICE -
BASECOVE
ADHESIVE YELLOW
ROUGH FLOOR
HA: 4
4-2
162501945-0008
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
2ND FL CELL #6 -
BASECOVE
ADHESIVE YELLOW
ROUGH FLOOR
HA: 4
5-1
162501945-0009
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
1ST FL CELL #9 -
12"X12" BEIGE FL
TILE BEIGE
SMOOTH FLOOR
HA: 5
Initial report from: 02/14/2025 12:45:06
Page 1 of 3ASB_PLM_0008_0002 - 2.31 Printed: 2/14/2025 12:45 PM
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162501945EMSL Order:
Customer ID: ACAD78J
Customer PO: 30267781.01
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
5-2
162501945-0010
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
2ND FL CELL #6 -
12"X12" BEIGE FL
TILE BEIGE
SMOOTH FLOOR
HA: 5
6-1
162501945-0011
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
1ST FL CELL #9 -
MASTIC OF HA-5
YELLOW ROUGH
FLOOR
HA: 6
6-2
162501945-0012
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
2ND FL CELL #6 -
MASTIC OF HA-5
YELLOW ROUGH
FLOOR
HA: 6
7-1
162501945-0013
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
CELL #1 1ST FLOOR
- 12X12 GRAY FL
TILE GRAY
SMOOTH FLOOR
HA: 7
7-2
162501945-0014
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
CELL #2 1ST FLOOR
- 12X12 GRAY FL
TILE GRAY
SMOOTH FLOOR
HA: 7
8-1
162501945-0015
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
CELL 1 1ST FLOOR -
MASTIC OF HA-7
YELLOW ROUGH
FLOOR
HA: 8
8-2
162501945-0016
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
CELL 2 1ST FLOOR -
MASTIC OF HA-7
YELLOW ROUGH
FLOOR
HA: 8
9-1
162501945-0017
None DetectedQuartz
Non-fibrous (Other)
40%
60%
Gray/Tan/White
Non-Fibrous
Homogeneous
SHOWER - EPOXY
FLOORING YELLOW
SPECKLED ROUGH
HA: 9
9-2
162501945-0018
None DetectedQuartz
Non-fibrous (Other)
40%
60%
Gray/Tan/White
Non-Fibrous
Homogeneous
REST ROOM -
EPOXY FLOORING
YELLOW SPECKLED
ROUGH
HA: 9
10-1
162501945-0019
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
REAR STAIRWELL -
RUBBER STAIR
TREAD ADHESIVE
YELLOW ROUGHT
FLOOR
HA: 10
10-2
162501945-0020
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
FRONT STAIRWELL
- RUBBER STAIR
TREAD ADHESIVE
YELLOW ROUGHT
FLOOR
HA: 10
11-1
162501945-0021
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
BREWSTER ROOF -
RUBBER ROOF
ADHESIVE YELLOW
ROUGTH ROOF
Page 2 of 3ASB_PLM_0008_0002 - 2.31 Printed: 2/14/2025 12:45 PM
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162501945EMSL Order:
Customer ID: ACAD78J
Customer PO: 30267781.01
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
HA: 11
11-2
162501945-0022
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
BREWSTER ROOF -
RUBBER ROOF
ADHESIVE YELLOW
ROUGTH ROOF
HA: 11
Analyst(s)
Maggie Hayden (11)
Paul Rihm (11)
Asbestos Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non- friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Indianapolis, IN NVLAP Lab Code 200188-0, AZ0939, CA 2575, CO AL-15132, TX 300262, A2LA Accredited - Certificate #2845.25
Page 3 of 3ASB_PLM_0008_0002 - 2.31 Printed: 2/14/2025 12:45 PM
OrderID: 162501945
O r d e r I D
P a g e f d e r I D
P a g e
5 Constitution Way, Unit A Woburn, MA 01801
Tel/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com / bostonlab@emsl.com
132505326EMSL Order:
Customer ID: ACAD78J
Customer PO: 30299180.01
Project ID:
Attention: Phone:Greg Donovan (617) 778-8212
Fax:ARCADIS U.S., Inc.
Received Date:25 Braintree Hill Office Park, Suite 200 09/11/2025 10:45 AM
Analysis Date:Braintree, MA 02184 09/11/2025
Collected Date: 09/11/2025
Project: 30299180 Task 01 - Brewster Bld. 16
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
12A
132505326-0001
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Brewster - Roof -
Gray Sealant on
HVAC & Penetration
Flashing
12B
132505326-0002
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Brewster - Roof -
Gray Sealant on
HVAC & Penetration
Flashing
13A
132505326-0003
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Brewster - Roof -
Gray Sealant on
Metal HVAC Housing
13B
132505326-0004
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Brewster - Roof -
Gray Sealant on
Metal HVAC Housing
14A
132505326-0005
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Brewster - Roof -
Black Seam Sealant
EPDM Roof
14B
132505326-0006
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Brewster - Roof -
Black Seam Sealant
EPDM Roof
Analyst(s)
Kevin McKenzie (6) Steve Grise, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non- friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Woburn, MA NVLAP Lab Code 101147-0, CT PH-0315, MA AA000188, RI PLM00139, VT AL998919, ME LB-0039
Initial report from: 09/11/2025 11:53:18
Page 1 of 1ASB_PLM_0008_0002 - 2.31 Printed: 9/11/2025 11:53 AM
OrderID: 132505326 d e r I D
P a g e
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162502039EMSL Order:
Customer ID: ACAD78J
Customer PO: 30267751.01
Project ID:
Attention: Phone:Greg Donovan (617) 778-8212
Fax:ARCADIS U.S., Inc.
Received Date:25 Braintree Hill Office Park, Suite 200 02/13/2025 10:05 AM
Analysis Date:Braintree, MA 02184 02/18/2025 - 02/19/2025
Collected Date:
Project: 99 LORING DRIVE, FARMINGHAM, MA MOD UNIT / 30267751.01
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1-1
162502039-0001
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
COMMON AREA -
12"X12" BEIGE FL
TILE
1-2
162502039-0002
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
COMMON AREA -
12"X12" BEIGE FL
TILE
2-1
162502039-0003
None DetectedNon-fibrous (Other)90%Cellulose10%Yellow
Non-Fibrous
Homogeneous
COMMON AREA -
MASTIC OF HA-1
2-2
162502039-0004
None DetectedNon-fibrous (Other)95%Cellulose5%Brown/Yellow
Non-Fibrous
Homogeneous
COMMON AREA -
MASTIC OF HA-1
3-1
162502039-0005
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
INMATE SHOWERS -
ADHESIVE OF
FORMICA PANEL
BOARD OVER
SHEETROCK
3-2
162502039-0006
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
INMATE BATHROOM
- ADHESIVE OF
FORMICA PANEL
BOARD OVER
SHEETROCK
4-1
162502039-0007
None DetectedGypsum
Non-fibrous (Other)
60%
10%
Cellulose
Glass
30%
<1%
Brown/White
Fibrous
Heterogeneous
COMMON AREA -
SHEETROCK
4-2
162502039-0008
None DetectedGypsum
Non-fibrous (Other)
70%
8%
Cellulose
Glass
20%
2%
Brown/White
Fibrous
Heterogeneous
COMMON AREA -
SHEETROCK
5-1
162502039-0009
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
COMMON AREA -
JOINT COMPOUND
5-2
162502039-0010
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
COMMON AREA -
JOINT COMPOUND
6-1
162502039-0011
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
COMMON AREA -
BASE COVE
ADHESIVE
6-2
162502039-0012
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
OFFICE - BASE
COVE ADHESIVE
7-1-Rubber Membrane
162502039-0013
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
EXTERIOR ROOF -
RUBBER
MEMBRANE +
ADHESIVE BOTTOM
LAYER
7-1-Adhesive
162502039-0013A
15% ChrysotileNon-fibrous (Other)83%Cellulose2%Gray
Non-Fibrous
Homogeneous
EXTERIOR ROOF -
RUBBER
MEMBRANE +
ADHESIVE BOTTOM
LAYER
Initial report from: 02/19/2025 11:14:09
Page 1 of 2ASB_PLM_0008_0002 - 2.31 Printed: 2/19/2025 11:14 AM
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162502039EMSL Order:
Customer ID: ACAD78J
Customer PO: 30267751.01
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
7-2-Rubber Membrane
162502039-0014
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
EXTERIOR ROOF -
RUBBER
MEMBRANE +
ADHESIVE BOTTOM
LAYER
7-2-Adhesive
162502039-0014A
Positive Stop (Not Analyzed)EXTERIOR ROOF -
RUBBER
MEMBRANE +
ADHESIVE BOTTOM
LAYER
8-1
162502039-0015
None DetectedNon-fibrous (Other)5%Cellulose95%Brown/Black
Fibrous
Homogeneous
EXTERIOR ROOF -
1" ISOL INSULATION
2ND LAYER
8-2
162502039-0016
None DetectedNon-fibrous (Other)5%Cellulose95%Brown/Black
Fibrous
Homogeneous
EXTERIOR ROOF -
1" ISOL INSULATION
2ND LAYER
9-1
162502039-0017
None DetectedNon-fibrous (Other)30%Cellulose70%Black
Fibrous
Homogeneous
EXTERIOR ROOF -
TAR PAPER 3RD
LAYER
9-2
162502039-0018
None DetectedNon-fibrous (Other)20%Cellulose80%Black
Fibrous
Homogeneous
EXTERIOR ROOF -
TAR PAPER 3RD
LAYER
10-1
162502039-0019
None DetectedNon-fibrous (Other)30%Cellulose70%Tan/Black
Fibrous
Homogeneous
EXTERIOR ROOF -
RUBBER ROOF
ADHESVIE TOP
LAYER
10-2
162502039-0020
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
EXTERIOR ROOF -
RUBBER ROOF
ADHESVIE TOP
LAYER
Analyst(s)
Amanda Straw (10)
Hilary Jarvis (11)
Asbestos Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Indianapolis, IN NVLAP Lab Code 200188-0, AZ0939, CA 2575, CO AL-15132, TX 300262, A2LA Accredited - Certificate #2845.25
Initial report from: 02/19/2025 11:14:09
Page 2 of 2ASB_PLM_0008_0002 - 2.31 Printed: 2/19/2025 11:14 AM
OrderID: 162502039 d e r I D
P a g e d e r I D
P a g e
APPENDIX C
Laboratory Reports – RCRA-8 Metals
Project Name:
Customer PO:
EMSL Sales Rep:
Reported:
ARCADIS U.S., Inc. [ACAD78J]
25 Braintree Hill Office Park, Suite 200
Braintree, MA 02184
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047 www.emsl.com
Greg DonovanAttention:
(617) 778-8212 greg.donovan@arcadis.com
30267781 Task: 01
Received: 02/13/2025 10:05
02/20/2025 17:07
Christopher Brandt
EMSL Order ID: 162551775
LIMS Reference ID: CD51775
EMSL Customer ID: ACAD78J
99 Loring Drive, Framingham, MA Brewster-1
Analytical Results
Analyte Results RL Q DF Analysis Date
& AnalystWeight(g) Prep Date
& Tech
Analytical
MethodPrep Method
Client Sample ID: PC-1/Gray, metal, door, intact, brewster-1, 1st floor janitor closet, janitor closet Date Sampled: 02/12/25
Matrix: Solid LIMS Reference ID: CD51775-01
1Arsenic 02/19/25 JW 02/19/25 JW<3.6 mg/kg 3.6 mg/kg SW846 3050B SW-846 6010D0.2812
1Barium 02/19/25 JW 02/19/25 JW4300 mg/kg 18 mg/kg SW846 3050B SW-846 6010D0.2812
1Cadmium 02/19/25 JW 02/19/25 JW0.98 mg/kg 0.71 mg/kg SW846 3050B SW-846 6010D0.2812
1Chromium 02/19/25 JW 02/19/25 JW18 mg/kg 1.8 mg/kg SW846 3050B SW-846 6010D0.2812
1Lead 02/19/25 JW 02/19/25 JW3.8 mg/kg 3.6 mg/kg SW846 3050B SW-846 6010D0.2812
1Mercury 02/20/25 JW 02/20/25 JW<0.24 mg/kg 0.24 mg/kg SW846 7471B SW846 7471B0.1045
1Selenium 02/19/25 JW 02/19/25 JW<7.1 mg/kg 7.1 mg/kg SW846 3050B SW-846 6010D0.2812
1Silver 02/19/25 JW 02/19/25 JW1.0 mg/kg 0.71 mg/kg SW846 3050B SW-846 6010D0.2812
Sample Comments:
Client Sample ID: PC-2/White, paneling, wall intact, brewster-1, 1st floor day room Date Sampled: 02/12/25
Matrix: Solid LIMS Reference ID: CD51775-02
1Arsenic 02/19/25 JW 02/19/25 JW<2.8 mg/kg 2.8 mg/kg SW846 3050B SW-846 6010D0.3547
1Barium 02/19/25 JW 02/19/25 JW14 mg/kg 14 mg/kg SW846 3050B SW-846 6010D0.3547
1Cadmium 02/19/25 JW 02/19/25 JW<0.56 mg/kg 0.56 mg/kg SW846 3050B SW-846 6010D0.3547
1Chromium 02/19/25 JW 02/19/25 JW<1.4 mg/kg 1.4 mg/kg SW846 3050B SW-846 6010D0.3547
1Lead 02/19/25 JW 02/19/25 JW<2.8 mg/kg 2.8 mg/kg SW846 3050B SW-846 6010D0.3547
1Mercury 02/20/25 JW 02/20/25 JW<0.27 mg/kg 0.27 mg/kg SW846 7471B SW846 7471B0.0914
1Selenium 02/19/25 JW 02/19/25 JW<5.6 mg/kg 5.6 mg/kg SW846 3050B SW-846 6010D0.3547
1Silver 02/19/25 JW 02/19/25 JW2.0 mg/kg 0.56 mg/kg SW846 3050B SW-846 6010D0.3547
Sample Comments:
Client Sample ID: PC-3/Brown, flooring, floor, intact, brewster-1, 1st floor bathrm Date Sampled: 02/12/25
Matrix: Solid LIMS Reference ID: CD51775-03
1Arsenic 02/19/25 JW 02/19/25 JW5.7 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5057
1Barium 02/19/25 JW 02/19/25 JW16 mg/kg 9.9 mg/kg SW846 3050B SW-846 6010D0.5057
1Cadmium 02/19/25 JW 02/19/25 JW<0.40 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5057
1Chromium 02/19/25 JW 02/19/25 JW70 mg/kg 0.99 mg/kg SW846 3050B SW-846 6010D0.5057
1Lead 02/19/25 JW 02/19/25 JW2.2 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5057
1Mercury 02/20/25 JW 02/20/25 JW<0.23 mg/kg 0.23 mg/kg SW846 7471B SW846 7471B0.1096
1Selenium 02/19/25 JW 02/19/25 JW<4.0 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.5057
1Silver 02/19/25 JW 02/19/25 JW<0.40 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5057
Sample Comments:
[TOC_1]Sample Results[TOC]
EMSL Sales Rep:
Reported:
ARCADIS U.S., Inc. [ACAD78J]
25 Braintree Hill Office Park, Suite 200
Braintree, MA 02184
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047 www.emsl.com
Greg DonovanAttention:
(617) 778-8212 greg.donovan@arcadis.com
30267781 Task: 01
Received: 02/13/2025 10:05
02/20/2025 17:07
Christopher Brandt
EMSL Order ID: 162551775
LIMS Reference ID: CD51775
EMSL Customer ID: ACAD78J
99 Loring Drive, Framingham, MA Brewster-1
Analytical Results
(Continued)
Analyte Results RL Q DF Analysis Date
& AnalystWeight(g) Prep Date
& Tech
Analytical
MethodPrep Method
Client Sample ID: PC-4/Red, metal, wall, intact, brewster-2, exterior of building Date Sampled: 02/12/25
Matrix: Solid LIMS Reference ID: CD51775-04
1Arsenic 02/19/25 JW 02/19/25 JW<7.1 mg/kg 7.1 mg/kg SW846 3050B SW-846 6010D0.1418
1Barium 02/19/25 JW 02/19/25 JW330 mg/kg 35 mg/kg SW846 3050B SW-846 6010D0.1418
1Cadmium 02/19/25 JW 02/19/25 JW<1.4 mg/kg 1.4 mg/kg SW846 3050B SW-846 6010D0.1418
1Chromium 02/19/25 JW 02/19/25 JW18 mg/kg 3.5 mg/kg SW846 3050B SW-846 6010D0.1418
1Lead 02/19/25 JW 02/19/25 JW45 mg/kg 7.1 mg/kg SW846 3050B SW-846 6010D0.1418
1Mercury 02/20/25 JW 02/20/25 JW<0.26 mg/kg 0.26 mg/kg SW846 7471B SW846 7471B0.0948
1Selenium 02/19/25 JW 02/19/25 JW<14 mg/kg 14 mg/kg SW846 3050B SW-846 6010D0.1418
1Silver 02/19/25 JW 02/19/25 JW1.9 mg/kg 1.4 mg/kg SW846 3050B SW-846 6010D0.1418
Sample Comments:
Client Sample ID: PC-5/Beige, wood, wall, intact, brewster-2, exterior of building Date Sampled: 02/12/25
Matrix: Solid LIMS Reference ID: CD51775-05
1Arsenic 02/19/25 JW 02/19/25 JW2.2 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5098
1Barium 02/19/25 JW 02/19/25 JW37 mg/kg 9.8 mg/kg SW846 3050B SW-846 6010D0.5098
1Cadmium 02/19/25 JW 02/19/25 JW<0.39 mg/kg 0.39 mg/kg SW846 3050B SW-846 6010D0.5098
1Chromium 02/19/25 JW 02/19/25 JW24 mg/kg 0.98 mg/kg SW846 3050B SW-846 6010D0.5098
1Lead 02/19/25 JW 02/19/25 JW2.6 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5098
1Mercury 02/20/25 JW 02/20/25 JW<0.23 mg/kg 0.23 mg/kg SW846 7471B SW846 7471B0.1067
1Selenium 02/19/25 JW 02/19/25 JW<3.9 mg/kg 3.9 mg/kg SW846 3050B SW-846 6010D0.5098
1Silver 02/19/25 JW 02/19/25 JW<0.39 mg/kg 0.39 mg/kg SW846 3050B SW-846 6010D0.5098
Sample Comments:
EMSL Sales Rep:
Reported:
ARCADIS U.S., Inc. [ACAD78J]
25 Braintree Hill Office Park, Suite 200
Braintree, MA 02184
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047 www.emsl.com
Greg DonovanAttention:
(617) 778-8212 greg.donovan@arcadis.com
30267781 Task: 01
Received: 02/13/2025 10:05
02/20/2025 17:07
Christopher Brandt
EMSL Order ID: 162551775
LIMS Reference ID: CD51775
EMSL Customer ID: ACAD78J
99 Loring Drive, Framingham, MA Brewster-1
CertificationsAnalyte
Certified Analyses included in this Report
SW-846 6010D in Solid
16-A2LA ChemistryArsenic
16-A2LA ChemistryBarium
16-A2LA ChemistryCadmium
16-A2LA ChemistryChromium
16-A2LA ChemistryLead
16-A2LA ChemistrySelenium
16-A2LA ChemistrySilver
SW846 7471B in Solid
16-A2LA ChemistryMercury
[TOC_1]Certified
Analyses[TOC]
List of Certifications
Code Description Number Expires
16-MO 10180Missouri Drinking Water 03/31/2026
16-NYDOH 12130New York Potable Water, Metals Solid and Hazardous Waste - Asbestos 04/01/2025
16-AIHA ELLAP 157245EMSL Analytical, Inc. Indianapolis, IN AIHA-LAP, LLC ELLAP Accredited 06/01/2025
16-AIHA IHLAP 157245EMSL Analytical, Inc. Indianapolis, IN AIHA-LAP, LLC IHLAP Accredited 06/01/2025
16-CA ELAP 2575California Metals in DW, Chemistry and Bulk Asbestos in Hazardous Waste 06/30/2025
16-A2LA Food 2845.11A2LA Food Microbiology 01/31/2026
16-A2LA Chemistry 2845.25A2LA Environmental and Chemistry 01/31/2026
16-IN Metals/Asbestos C-49-09Indiana Lead and Metals and Asbestos in Drinking Water 12/31/2026
16-OHDOH E10040Ohio - Lead in Paint Chips, Wipes, Soil and Air 05/03/2025
16-FLDOH E871170Florida Asbestos and Metals in Drinking Water, PCBs 06/30/2025
16-NJDEP IN002New Jersey Metals, Organics and Inorganics in DW PCBs 06/30/2025
16-IN Colilert/HPC M-49-06Indiana Colilert and HPC 12/31/2026
Please see the specific Field of Testing (FOT) on www.emsl.com <http://www.emsl.com> for a complete listing of parameters for which EMSL is certified.
[TOC_1]Certifications[TOC]
Notes and Definitions
Item Definition
(Dig) For metals analysis, sample was digested.
[2C] Reported from the second channel in dual column analysis.
DF Dilution Factor
MDL Method Detection Limit.
ND Analyte was NOT DETECTED at or above the detection limit.
NR Spike/Surrogate showed no recovery.
Q Qualifier
RL Reporting Limit
Wet Sample is not dry weight corrected.
[TOC_1]Qualifiers, Definitions and Disclaimer[TOC]
EMSL Sales Rep:
Reported:
ARCADIS U.S., Inc. [ACAD78J]
25 Braintree Hill Office Park, Suite 200
Braintree, MA 02184
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047 www.emsl.com
Greg DonovanAttention:
(617) 778-8212 greg.donovan@arcadis.com
30267781 Task: 01
Received: 02/13/2025 10:05
02/20/2025 17:07
Christopher Brandt
EMSL Order ID: 162551775
LIMS Reference ID: CD51775
EMSL Customer…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .