Amendment 018 - DRIVe EZ BAA.pdf

PDF 184 KB Posted

Attached to
BARDA DRIVe EZ-BAA (EZBAA - 22-100-SOL-00003)
Solicitation number
DRIVeEZBAA22100SOL00003
Issued by

View the file

Other files

File Type Posted
Amendment 037 - DRIVe EZ BAA.pdf PDF
Amendment 037 - DRIVe EZ BAA.pdf PDF
Amendment 036 - DRIVe EZ BAA.pdf PDF
Amendment 035 - DRIVe EZ BAA.pdf PDF
Amendment 034 - DRIVe EZ BAA.pdf PDF
Amendment 033 - DRIVe EZ BAA.pdf PDF
Amendment 032 - DRIVe EZ BAA.pdf PDF
Amendment 031 - DRIVe EZ BAA.pdf PDF
Amendment 030 - DRIVe EZ BAA.pdf PDF
Amendment 029 - DRIVe EZ BAA.pdf PDF
Amendment 028 - DRIVe EZ BAA.pdf PDF
Amendment 027 - DRIVe EZ BAA.pdf PDF
Amendment 026 - DRIVe EZ BAA.pdf PDF
Amendment 025 - DRIVe EZ BAA.pdf PDF
Amendment 024 - DRIVe EZ BAA.pdf PDF
Amendment 023 - DRIVe EZ BAA.pdf PDF
Amendment 022 - DRIVe EZ BAA.pdf PDF
Amendment 021 - DRIVe EZ BAA.pdf PDF
Amendment 020 - DRIVe EZ BAA.pdf PDF
Amendment 019 - DRIVe EZ BAA.pdf PDF
Amendment 019 - DRIVe EZ BAA.pdf PDF
Amendment 017 - DRIVe EZ BAA.pdf PDF
Amendment 016 - DRIVe EZ BAA.pdf PDF
Amendment 015 - DRIVe EZ BAA.pdf PDF
Amendment 014 - DRIVe EZ BAA.pdf PDF
Amendment 013 - DRIVe EZ BAA.pdf PDF
Amendment 012 - DRIVe EZ BAA.pdf PDF
Amendment 011 - DRIVe EZ BAA.pdf PDF
Amendment 010 - DRIVe EZ BAA.pdf PDF
Amendment 009 - DRIVe EZ BAA.pdf PDF
Amendment 008 - DRIVe EZ BAA.pdf PDF
Amendment 007 - DRIVe EZ BAA.pdf PDF
Amendment 006 - DRIVe EZ BAA.pdf PDF
Amendment 005 - DRIVe EZ BAA.pdf PDF
Amendment 004 - DRIVe EZ BAA.pdf PDF
Amendment 003 - DRIVe EZ BAA.pdf PDF
Amendment 002 - DRIVe EZ BAA.pdf PDF
Amendment 001 - DRIVe EZ BAA_10.18.22.pdf PDF
EZ-BAA-22-100-SOL-00003_10.18.22.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Office of Biomedical Advanced Research and Development Authority (BARDA) Division of Research, Innovation & Ventures

(DRIVe)

Amendment 018 Issuance for Easy Broad Agency Announcement

(EZ-BAA) BAA-22-100-SOL-00003

The purpose of this Amendment is the following:

1) Update the closing date for the following Area of

Interest (AOI):

AOI #16: Lab at Home

2) Revise the following Area of Interest (AOI):

3) Pause the following Area of Interest (AOI):

AOI #17: Digital MCMs

4) Update the closing date for the following Area of

Interest (AOI):

AOI #19: Healing Lungs

INTRODUCTION AND OVERVIEW INFORMATION

A. Development Opportunity Objective:

Under this Amendment, DRIVe is doing the following:

1) Updating the closing date for following research Area of Interest (AOI):

2) Revising the following research Area of Interest (AOI):

We are seeking abstract submissions for the following AOI:

EZ BAA AOI #16: Lab at Home

DRIVe is seeking proposals to develop novel instrumentation-based platform technologies for on-demand, simultaneous detection of multiple biochemical health markers at the point of need.

The goal is to obtain quantitative information about patients’ health status at the point of need, avoiding the long sample-to-answer times and personnel training requirements of traditional central laboratory testing that can lead to delays in receiving care. Such platforms could remove existing complications patients face in seeking remote diagnoses by physicians, including sample shipping or travel to sample collection sites. Enabling testing at the point of need could greatly improve the efficiency and accessibility of tools for infection detection, chronic disease management, clinical trial management etc., leading to a healthier population with reduced healthcare costs.

The goal of projects funded through this AOI is feasibility demonstration of inno vative enabling technologies that allow for simultaneous detection and quantification of several host biochemical markers in a multiplexed manner.

The instrumentation / platform technologies developed through this program are primarily intended for settings such as the home, but could also be useful in doctor’s offices, nursing homes, urgent care facilities, pharmacy clinics or anywhere access to analytical results at the point of need is vital. DRIVe does not specify a particular platform form factor or sensing modality and will consider devices ranging from portable benchtop formats to handheld or wearable platforms. Both single time point and continuous (or near-continuous) quantitative measurements will be accepted. Platform technologies will ideally provide results comparable to those from a central laboratory, when applicable, or to a relevant control assay.

Applicants should address the following in their proposals:

• The technological innovation, potentially including, but not limited to:

o how the technology addresses gaps in the capabilities of existing platforms, o how the technology innovates upon or differs from similar platforms, o how the technology uniquely addresses barriers to access such as cost, ease of use or time to result.

• The scientific premise for interrogating a specific set of host biomarkers using the proposed sample and method, as well as the clinical relevancy of those biomarkers in the BARDA context.

• The desired limit of detection and accuracy of the proposed sensing modality.

• A plan for comparison between the proposed solution and the laboratory standard in function and clinical value, including how the novel technology could replicate the central laboratory function and/or outcome.

• A plan to address critical feasibility issues that need to be demonstrated as a prerequisite to advancing the platform to a specific product application.

• A plan to demonstrate simultaneous detection of host biochemical markers from a single clinical sample in a multiplex assay.

• Preliminary data that supports the key assumptions of the proposal.

The respondent should explain how the choice of host biomarkers and specific use case address BARDA’s mission. Examples of desired use cases include detection of host biochemical markers relevant to infectious diseases, chemical/radiological injury, or rapid results of critical cardiac function for clinical trial monitoring, among others. Biochemical markers of interest include, but are not limited to lipids, proteins, nucleic acids, and small molecules; examples include cytokines, bilirubin, creatinine, CRP, uric acid, triglycerides, hemoglobin, iron, calcium, potassium, IP-10, TRAIL, cortisol, etc. This program has a specific interest in broad detection capabilities of a platform.

Responsiveness criteria:

• Innovative platform technologies should ideally provide quantitative data/detection of biomarkers that is compatible with use by untrained personnel in the home or other CLIA-waived environment.

• The proposed platform technology should be readily adaptable to a broad menu of test panels

(e.g., detecting proteins, large molecules, and lipids from a single sample) to cover a wide range of disease states as well as standard health assessments.

• Both desktop/portable and wearable form factors will be considered. Among wearable form factors, microneedle patches, smart tattoos, eye lenses and other innovations are desired.

• Proposals do not need to include interpretation of the biomarker levels for diagnostic purposes.

The interpretation of the results will be performed by healthcare professionals.

• Sample specimens should preferably be compatible with non-invasive or minimally invasive collection at home by an untrained individual 18 years of age or older. Acceptable samples include saliva, urine, sweat, breath, nasal swabs, finger stick blood, capillary blood, and interstitial fluid. Submissions focusing on novel sample types, however, should demonstrate the specific value of these sample types and correlation of host biomarkers with venous samples.

• The entire testing process including sample collection, sample application to test, and test readout should preferably take no more than 2 hours. Alternatively, devices in wearable form factors producing multiple quantitative measurements per day will be considered.

• Any visual readouts confirming proper use of the system should be easy to interpret by lay individuals and those with visual impairment.

• The analytical performance (i.e., limit of detection, accuracy) of the proposed sensing modality should be clinically relevant and commensurate with up-to-date regulatory and public health guidance. Ideally, performance of the platform would be similar to the FDA-approved gold standard.

• Priority will be given to platforms being developed in the United States or those whose target markets include the US.

Other characteristics:

• The system may include a smartphone, mobile device, portable desktop device, or instrument for collection and transfer of data to a medical care provider, however, projects focusing chiefly on data transfer mechanisms will not be prioritized.

• Projects focused on interpreting data will not be prioritized.

• While projects may include the development or implementation of machine learning algorithms, proposals whose primary innovation combines ML or AI with existing technologies will not be considered.

• The collection and transfer of data by the device or a mobile device should follow accepted data standards to allow connectivity with medical systems, as well as comply with current privacy laws and guidelines (e.g. HIPAA compliance).

• Plans for product commercialization, including a regulatory pathway, are desired but not required.

Non-responsive / out-of-scope topics:

• Technologies requiring venous blood draws or invasive samples.

• Technologies focusing on biophysical health markers (e.g., blood pressure, respiratory rate).

• Technologies involving direct pathogen detection or pathogen-based biomarker detection.

• Proposals combining at-home sample collection with testing at another location.

• Proposals focusing on clinical validation or clinical utility of existing technologies; infection severity/sepsis; or interpretation of quantitative biochemical results for diagnostic or triage purposes are not responsive.

3) Pausing the following research Area of Interest (AOI):

AOI #17: Digital MCMs

4) Updating the closing date for the following research Area of Interest (AOI):

AOI #19: Healing Lungs

B. Eligible Respondents & Scope Parameters:

This Amendment is open to all responsible sources as described in the EZ-BAA. Abstract submissions that do not conform to the requirements outlined in the EZ-BAA may be considered non-responsive and will not be reviewed. In particular, an entity must have an active registration with https://sam.gov at the time of submission to be reviewed. If not, the https://sam.gov/ abstract submission will not be reviewed and will be rejected. Please do not attempt to submit an abstract if your registration is not active in https://sam.gov.

IMPORTANT NOTE: Interested vendors are strongly encouraged to request and schedule a pre-submission call before submitting an abstract. This request should include the project title, key project staff, and a brief description of the proposed project. Please submit the requests to the following:

AOI #16: Lab at Home (homediagnostics@hhs.gov) AOI #17: Digital MCMs (digitalhealth@hhs.gov) AOI #19: Healing Lungs (HealingLungs@hhs.gov)

The closing date for abstract submissions for these AOIs is listed below.

Area of Interest Closing Date for Abstract Submissions

#17 12:00pm ET on December 15, 2023

#16, 19 12:00pm ET on March 15, 2024

Note: In an effort to streamline the EZ-BAA, all Areas of Interest will be open for a few months at a time following a staggered approach. This is being done in an effort to encourage high-quality submissions earlier in the fiscal year allowing adequate review time. Depending on programmatic need and funding availability, Areas of Interest may be reopened for another period of time.

C. Number of Awards:

Multiple awards are anticipated and are dependent upon the program priorities, scientific/technical merit of abstract submissions, how well the abstract submissions fit within the goals of the AOI, and the availability of funding. The program funding is subject to change based on the Government’s discretion.

Funding is limited, so we encourage any interested vendors to reach out to the respective program as soon as possible before submitting an abstract.

D. Amendment Application Process:

This Amendment will follow the same submission process and review procedures as those established under this EZ-BAA, unless otherwise noted. For complete details, please read the EZ-BAA in its entirety along with all amendments.

IMPORTANT NOTE: Respondents who are awarded a contract under each of these AOIs will be required to share any collected, de-identified data in an effort to advance the field and knowledge. Interested Respondents are strongly encouraged to commercialize their technology and algorithms, however note that consistent with BARDA’s mission and federal standards, data collected through the use of government funding will be delivered to BARDA for government usage pursuant to applicable regulations and law.

https://sam.gov/ mailto:homediagnostics@hhs.gov mailto:digitalhealth@hhs.gov mailto:HealingLungs@hhs.gov