PDF 3 MB Posted

Attached to
N063--Replace Nurse Call System Federal contract opportunity
Solicitation number
36C24624R0005
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

This is a solicitation for a nurse call system replacement project at the Veterans Affairs Medical Center in Salem, Virginia. The contractor shall provide all labor, materials, equipment, and supervision to remove existing nurse call systems and install new infrastructure, networks, and devices across five primary care clinics and specialty care clinics on floors 2J, 2H, 3J, and 3H. The new system must be fully compatible and integrated with the facility's existing Jeron 790 nurse call system.

View the file

Other files for this federal contract opportunity

Other files attached to N063--Replace Nurse Call System, newest first.
File Type Posted
VA Wage Determination 1.05.2024.pdf PDF
36C24624R0005 0003.docx DOCX document
Drawings rev01.pdf PDF
Questions and Responses.pdf PDF
36C24624R0005 0002.docx DOCX document
852.239-70 SECURITY REQUIREMENTS FOR INFORMATION TECHNOLOGY RESOURCES.docx DOCX document
S04 Site Visit Nurse Call 1-9-2024.pdf PDF
36C24624R0005 0001.docx DOCX document
36C24624R0005.docx DOCX document
Wage Determination VA20230172 12.22.2023.pdf PDF
Specifications - Final.pdf PDF
SOW - Final.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:0

P

M

EY-000

COVER SHEET REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

5, 143

06/16/2023 NMT NMT

SHEET LIST

Sheet Number Sheet Name

EY-000 COVER SHEET

EY-001 ELECTRICAL SYMBOLS AND ABBREVIATIONS

EYD-300 NURSE CALL - BUILDING 5 - BASEMENT FLOOR - NURSE CALL DEMOLITION PLAN

EYD-301 NURSE CALL - BUILDING 143 - BASEMENT FLOOR - NURSE CALL DEMOLITION PLAN

EYD-302 NURSE CALL - BUILDING 143 - BASEMENT FLOOR - NURSE CALL DEMOLITION PLAN

EYD-320 NURSE CALL - BUILDING 143 - SECOND FLOOR - 2H - NURSE CALL DEMOLITION PLAN

EYD-321 NURSE CALL - BUILDING 143 - SECOND FLOOR - 2J - NURSE CALL DEMOLITION PLAN

EYD-330 NURSE CALL - BUILDING 143 - THIRD FLOOR - 3H - NURSE CALL DEMOLITION PLAN

EYD-331 NURSE CALL - BUILDING 143 - THIRD FLOOR - 3J - NURSE CALL DEMOLITION PLAN

EY-300 NURSE CALL - BUILDING 5 - BASEMENT FLOOR - NURSE CALL NEW PLAN

EY-301 NURSE CALL - BUILDING 143 - BASEMENT FLOOR - NURSE CALL NEW PLAN

EY-302 NURSE CALL - BUILDING 143 - BASEMENT FLOOR - NURSE CALL NEW PLAN

EY-320 NURSE CALL - BUILDING 143 - SECOND FLOOR - 2H - NURSE CALL NEW PLAN

EY-321 NURSE CALL - BUILDING 143 - SECOND FLOOR - 2J - NURSE CALL NEW PLAN

EY-330 NURSE CALL - BUILDING 143 - THIRD FLOOR - 3H - NURSE CALL NEW PLAN

EY-331 NURSE CALL - BUILDING 143 - THIRD FLOOR - 3J - NURSE CALL NEW PLAN

EY-400 ORIENTATION AND ZONING PLAN

Grand total: 17

REPLACE NURSE CALL

VETERANS AFFAIRS MEDICAL CENTER

SALEM, VA 24153

PROJECT NO. 658-22-101

Revisions: Date:

ELECTRICAL ABBREVIATIONS

ABBREVIATION DESCRIPTION

REFER TO OTHER SCHEDULES AND NOTES FOR ADDITIONAL ABBREVIATIONS.

MOUNTING HEIGHT TO CENTERLINE (ABOVE FINISHED FLOOR)

AMPERE

AMPERE FRAME

ABOVE FINISHED FLOOR

ALUMINUM

AMPERE TRIP

CEILING

CIRCUIT BREAKER

CORRELATED COLOR TEMPERATURE

COPPER

DATA (WHEN APPLIED TO COMMUNICATIONS OUTLET)

DEMO (WHEN APPLIED TO EXISTING/DEMO ITEMS)

EXISTING

ELECTRICALLY OPERATED

ENERGY REDUCING MAINTENANCE SWITCH

FUSE

FULL LOAD AMPS

GROUND FAULT CIRCUIT INTERRUPTER

GROUND FAULT ALARM

GROUND FAULT PROTECTION

HORSEPOWER

KILOAMPERE INTERRUPTING CAPACITY

KILOVOLT AMPERE

KILOWATT

MAXIMUM

MINIMUM CIRCUIT AMPS

MAIN CIRCUIT BREAKER

MINIMUM

MAIN LUGS ONLY

MANUALLY OPERATED

NORMALLY CLOSED

NON-FUSED

NOT IN CONTRACT

NORMALLY OPEN

POLES

PARTIAL

RELOCATE

SHORT CIRCUIT CURRENT RATING

SURGE PROTECTIVE DEVICE

SHUNT TRIP

TYPICAL

UNLESS NOTED OTHERWISE

VOICE

WALL PHONE

WIRE

WEATHER RESISTANT

TRANSFORMER

ZONE SELECTIVE INTERLOCKING

A

AF

AFF

AL

AT

C

CB

CCT

CU

D

D

E

EO

ERMS

F

FLA

G, GFCI

GFA

GFP

HP

KAIC

KVA

KW

MAX

MCA

MCB

MIN

MLO

MO

NC

NF

NIC

NO

P

PART

R

SCCR

SPD

ST

TYP

UNO

V

W

W

WR

XFMR

ZSI

A. BRANCH CIRCUITS WITH A TOTAL LENGTH LONGER THAN 75' SHALL UTILIZE #10 AWG CONDUCTORS.

RECEPTACLE BRANCH CIRCUITS WITH A TOTAL LENGTH LONGER THAN 150' SHALL UTILIZE #8 AWG

CONDUCTORS.

B. FOR ALL CONDUIT AND OTHER ITEMS PENETRATING A FIRE RATED WALL, PROVIDE UL LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM THAT IS SPECIFIC TO THE WALL CONSTRUCTION ASSEMBLY AND COMPLIANT WITH ASTM E814. INSTALL SYSTEM IN STRICT COMPLIANCE WITH THE FIRE STOPPING MANUFACTURER’S U.L. APPROVED DETAIL. WHERE EXISTING WALLS ARE BEING UPGRADED TO FIRE RATED WALLS OR THE FIRE RATING IS BEING MODIFIED, PROVIDE U.L. LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM FOR ALL NEW AND EXISTING PENETRATIONS. REFER TO THE ARCHITECTURAL LIFE

SAFETY PLANS FOR LOCATIONS OF FIRE RATED WALLS.

C. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR, AT NO ADDITIONAL

COST TO THE OWNER.

D. NEW WIRING DEVICES AND ASSOCIATED COVERPLATES SHALL MATCH EXISTING FINISH OF SIMILAR

INSTALLED DEVICES.

E. THE SELECTED EQUIPMENT AIC RATINGS ARE BASED ON THE IMPEDANCES FOR CONDUCTORS AND TRANSFORMERS USED IN THE CALCULATIONS. IF DIFFERENT EQUIPMENT OR DIFFERENT CONFIGURATIONS

ARE SELECTED FOR INSTALLATION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING

ADEQUATELY RATED EQUIPMENT THAT MEETS APPLICABLE SELECTIVE COORDINATION GOALS AND

PROVIDES SIMILAR INCIDENT ENERGY RISK OF ARC FLASH HAZARDS.

F. ALL CRITICAL AND LIFE SAFETY BRANCH CIRCUITS, INCLUDING LIGHTING AND WALL RECEPTACLES, SHALL BE MECHANICALLY PROTECTED PER NEC 517.31(C)(3). NON-FLEXIBLE RACEWAY SHALL BE USED FOR CRITICAL AND LIFE SAFETY BRANCH CIRCUITS, EXCEPT THAT THE FINAL CONNECTION TO VIBRATING EQUIPMENT OR LIGHT FIXTURES IF THE TOTAL LENGTH OF FLEXIBLE RACEWAY IS 6' OR LESS ACROSS THE

ENTIRE CIRCUIT LENGTH.

G. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO INDEPENDENTLY SUPPORT ALL EXISTING TO REMAIN

CABLING.

H. REUSE EXISTING CONDUIT AND ROUGH-INS TO THE GREATEST EXTENT PRACTICAL. WHERE EXISTING ROUGH-INS DO NOT EXIST, PROVIDE JUNCTION BOX AND CONDUIT RECESSED IN WALL TO ABOVE ACCESSIBLE CEILING. SURFACE MOUNT CONDUITS AND BOXES ARE ONLY PERMITTED FOR EXISTING CMU

OR CLAY TILE WALLS. PATCH AND PAINT WALLS TO MATCH EXISTING FINISHES.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

ELECTRICAL GENERAL NOTES:

LEGEND: (LOW VOLTAGE COORDINATION LEGEND)

CF: CONTRACTOR FURNISHED

CI: CONTRACTOR INSTALLED

OF: OWNER FURNISHED

OI: OWNER INSTALLED

REMARKS: (LOW VOLTAGE COORDINATION LEGEND)

1. NURSE CALL SYSTEM IS AN EXTENSION OF AN EXISTING JERON PROVIDER 790 SYSTEM. NEW DEVICES SHALL FUNCTION

AS AN EXTENSION OF THE EXISTING SYSTEM.

GENERAL NOTES: (LOW VOLTAGE COORDINATION LEGEND)

A. REFER TO SYMBOL LEGENDS AND SPECIFICATIONS FOR SPECIFIC REQUIREMENTS.

B. COORDINATE ROUGH-IN REQUIREMENTS WITH FINAL EQUIPMENT SELECTION FOR ALL SYSTEMS.

C. COORDINATE ROUGH-IN REQUIREMENTS WITH OWNER FOR OWNER FURNISHED SYSTEMS.

D. CONDUITS SHALL ROUTE CONCEALED INSIDE WALL TO ABOVE NEAREST ACCESSIBLE CEILING SPACE, UNLESS

OTHERWISE INDICATED.

E. WHERE CABLING IS CONTRACTOR FURNISHED AND CONTRACTOR INSTALLED, TERMINATE AND TEST ALL CABLING PER

SPECIFICATION.

A. THE INTENT OF THE DEMOLITION DRAWINGS IS TO DEFINE THE SCOPE OF ELECTRICAL DEMOLITION WORK.

PROVIDE DEMOLITION FOR ITEMS AS SHOWN.

B. ITEMS INDICATED WITH A SUBSCRIPT 'E' SHALL BE EXISTING TO REMAIN (E-EXISTING). ITEMS INDICATED WITH A SUBSCRIPT 'D' OR SHOWN DASHED SHALL BE REMOVED (D-DEMOLITION). ITEMS INDICATED WITH A SUBSCRIPT 'R' SHALL BE REMOVED, STORED, AND REINSTALLED PER NEW WORK (R-RELOCATION).

C. THE OWNER SHALL HAVE FIRST SALVAGE RIGHTS TO ALL ITEMS REMOVED. IF OWNER REFUSES SALVAGE, CONTRACTOR IS RESPONSIBLE FOR DISPOSAL.

D. ABANDON CONCEALED CONDUITS WHERE WALLS ARE NOT REMOVED. CONCEALED CONDUITS MAY BE REUSED WHERE AVAILABLE. WHERE EXISTING CIRCUITING/CABLING IS TO BE DEMOLISHED AND NOT

REUSED, REMOVE CONDUCTORS AND ASSOCIATED ACCESSIBLE RACEWAYS/CONDUIT BACK TO THE

SOURCE. WHERE EXISTING ELECTRICAL CONDUITS SERVING CIRCUITS TO BE DEMOLISHED ARE

EMBEDDED IN CONCRETE FLOORS OR WALLS, CONDUITS MAY BE ABANDONED IN PLACE. EXISTING CONDUCTORS SHALL BE REMOVED BACK TO SOURCE AND CONDUITS SHALL BE CUT AT SURFACE OF CONCRETE AND FILLED. EXISTING BACK BOXES AND CONDUITS REMAINING FROM DEVICES BEING REMOVED MAY BE UTILIZED FOR NEW DEVICES WHERE LOCATIONS PERMIT. REMOVE AND PATCH WHERE

BOXES ARE NOT REUSED.

E. SYSTEMS SERVING ADJACENT AREAS AND ITEMS THAT REMAIN SHALL BE MAINTAINED AT ALL TIMES.

MODIFY SYSTEMS AS REQUIRED THROUGHOUT CONSTRUCTION TO MAINTAIN CONTINUITY OF SERVICE. DO

NOT INTERRUPT SERVICE WITHOUT OWNER'S PRIOR WRITTEN APPROVAL. LIMIT DURATION OF

INTERRUPTION ONLY TO THE TIME NECESSARY FOR DISCONNECTION AND IMMEDIATE RECONNECTION.

INTERRUPTION TO SERVICE DEEMED BY OWNER AS ESSENTIAL MAY REQUIRE PREMIUM TIME AND SHALL BE INCLUDED WITH THE BID. EXTREME CARE SHALL BE TAKEN BY THE CONTRACTOR TO IDENTIFY EXISTING SYSTEM COMPONENTS ASSOCIATED WITH THESE SERVICES. APPROPRIATE METHODS OF MARKING THESE SHALL OCCUR TO ELIMINATE THE POSSIBILITY OF ACCIDENTAL INTERRUPTION. FOR CONDUIT AND CABLING THAT CAN REMAIN, PROVIDE SUPPORT AS REQUIRED. RELOCATE EXISTING JUNCTION BOXES THAT

BECOME INACCESSIBLE DUE TO NEW WORK.

F. PROTECT EXISTING ELECTRICAL EQUIPMENT THAT REMAINS. IF DAMAGED OR DISTURBED IN THE COURSE OF THE WORK, REMOVE DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF EQUAL CAPACITY, QUALITY, AND FUNCTIONALITY.

G. PATCH AND REPAIR OPENINGS IN EXISTING WALLS AND FLOORS RESULTANT FROM SPECIFIED ELECTRICAL

DEMOLITION. PATCH SHALL MATCH EXISTING CONSTRUCTION, FIRE RATING, AND FINISH.

(ELECTRICAL DEMOLITION NOTES APPLY TO ALL ELECTRICAL DEMOLITION PLANS AND

ALL ELECTRICAL DEMOLITION WORK)

ELECTRICAL DEMOLITION GENERAL NOTES:

Scale:

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

NO SCALE

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1 /2

:4

:5

A

M

EY-001

ELECTRICAL SYMBOLS AND ABBREVIATIONS REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

5, 143

06/16/2023 NMT NMT

ELECTRICAL MISC SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

CABLE TRAY PROVIDE CABLE TRAY AT LOCATIONS INDICATED ON PLANS. REFER TO FLOOR PLANS FOR TYPE DESIGNATION.

COORDINATE MOUNTING WITH OTHER TRADES AND REQUIREMENTS IN SPECIFICATION.

TYPE 'WIDTH x DEPTH", WIRE BASKET CABLE TRAY:

PROVIDE CABLE TRAY IN DIMENSION INDICATED ON FLOOR PLANS.

TYPE 'WIDTH LADDER', LADDER CABLE TRAY:

PROVIDE CABLE TRAY IN DIMENSION INDICATED ON FLOOR PLANS.

LIGHTING CONTROL TAG REFER TO LIGHTING CONTROL SCHEDULE FOR ADDITIONAL INFORMATION.

ELECTRICAL MISC SYMBOLS

PLAN SYMBOL NAME

BRANCH CIRCUIT CONCEALED IN

CEILING OR WALL

BRANCH CIRCUIT CONCEALED IN

FLOOR OR BELOW GRADE

CLEARANCE SPACE

CONDUIT BREAK

CONDUIT DOWN

CONDUIT STUB-OUT

CONDUIT UP

HOMERUN TO PANEL

G = GFCI CIRCUIT

(PART) = PARTIAL CIRCUIT

SWITCHED RECEPTACLE

LOW VOLTAGE COORDINATION LEGEND

SYSTEMS

ROUGH-INS &

PATHWAYS

CABLING &

TERMINATIONS

DEVICES &

EQUIPMENT REMARKS

NURSE CALL CF / CI CF / CI CF / CI 1

NURSE CALL SYMBOL LEGEND

PLAN SYMBOL NAME

DEFAULT

MOUNTING

HEIGHT ROUGH-IN DESCRIPTION

4 BUTTON STATION GENERAL:

PROVIDE NURSE CALL DEVICE AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH TYPE.

REFER TO PLANS FOR DESIGNATION. PROVIDE ROUGH-IN AND TRIM PER MANUFACTURER'S REQUIREMENTS.

TYPE 'CODE', FOUR BUTTON CODE STATION:

PROVIDE THE FOLLOWING BUTTONS:

1. BLUE BUTTON, LABEL 'CODE BLUE'

2. WHITE BUTTON, LABEL 'CODE WHITE'

3. PINK BUTTON, LABEL 'MET CODE'

4. BLANK BUTTON

TYPE 'STF/CODE', FOUR BUTTON STAFF ASSIST/CODE STATION:

PROVIDE THE FOLLOWING BUTTONS:

1. BLUE BUTTON, LABEL 'CODE BLUE'

2. WHITE BUTTON, LABEL 'CODE WHITE'

3. PINK BUTTON, LABEL 'MET CODE'

4. RED BUTTON, LABEL 'STAFF EMER'

TYPE 'STATUS', FOUR BUTTON STATUS STATION:

PROVIDE FOUR BUTTON STATION TO BE USED FOR WORKFLOW MANAGEMENT/ROOM STATUS FUNCTIONS.

COORDINATE WITH USING CLINIC FOR REQUIRED LABELING AND FUNCTION.

BEDSIDE STATION - PILLOW

SPEAKER

GENERAL:

PROVIDE NURSE CALL DEVICE AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH TYPE.

REFER TO PLANS FOR DESIGNATION. PROVIDE PATIENT BEDSIDE STATION WITH CODE BLUE AND STAFF EMERGENCY BUTTONS. PROVIDE WITH PILLOW SPEAKER. WHERE ROOM INCLUDES TV STATION, INCLUDE TV CONTROL IN PILLOW SPEAKER. PROVIDE ROUGH-IN AND TRIM PER MANUFACTURER'S REQUIREMENTS.

TYPE 'BSID-PLW', SINGLE BEDSIDE STATION WITH PILLOW SPEAKER:

PROVIDE SINGLE PATIENT BEDSIDE STATION.

TYPE '2BSID-PLW', DUAL BEDSIDE STATION WITH PILLOW SPEAKERS:

PROVIDE DUAL PATIENT BEDSIDE STATION.

DOME LIGHT - CEILING -- 4" SQUARE, 2-1/8"

DEEP BACK BOX

WITH 1 GANG

TRIM RING

PROVIDE ONE (1) 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CORRIDOR CEILING SPACE WHEN INSTALLED

WITHIN GYP CEILING.

NURSE CALL CONTROL CABINET

- SURFACE

48" -- CIRCUIT CONTROL CABINET TO 20A 120V BRANCH CIRCUIT IN LOCAL [CRITICAL] [NORMAL] BRANCH PANEL OF THE ASSOCIATED CONSTRUCTION PHASE. REFER TO FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATIONS.

COORDINATE CONNECTION REQUIREMENTS WITH FINAL EQUIPMENT SELECTION AND PROVIDE NEMA 5-20

RECEPTACLE OR HARD-WIRED CONNECTION TO CABINET AS REQUIRED.

NURSE DESK CONSOLE GENERAL:

WHERE 'CONS' TAG IS FOLLOWED BY A NUMBER, THAT NUMBER DESIGNATES THE ORDER THAT CALLS RING THE CONSOLE. CALLS SHALL RING THE LOWER NUMBERED CONSOLE BEFORE ROLLING OVER TO THE NEXT HIGHER

NUMBERED CONSOLE. COORDINATE RING TIME BEFORE ROLL OVER WITH NURSE MANAGER.

ZONE LIGHT - CEILING -- 4" SQUARE, 2-1/8"

DEEP BACK BOX

WITH 1 GANG

TRIM RING

PROVIDE ONE (1) 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CORRIDOR CEILING SPACE WHEN INSTALLED

WITHIN GYP CEILING.

NURSE CALL SYMBOLS

PLAN SYMBOL NAME

DEFAULT

MOUNTING

HEIGHT ROUGH-IN

DOME LIGHT

PATIENT CALL PUSH BUTTON

PULL CORD

PULL CORD - WITH AUDIO

REMOTE AUDIO

STAFF ASSIST STATION

TV

RAUD

DN

DN

DN

SWING SPACE

PACT EXAM

PACT EXAM

2A

2I

2E

OFFICE

2D

GUEST/PATIENT

WiFi AREA

214 SF ±

PALMS

CASCADE FALLS

LILAC

GERANIUM

POPPY ROOM

HOLLY HOCK

CASCADE FALLS

WILLOW ROOM

HANDICAPPED RAMP

HANDICAPPED RAMP

HANDICAPPED RAMP

FP

UP

DN

DN

DN

UP

2J

2G

1R

1N

1L

1B

3E

CB-5

CB-4

2E 2F

2I2C

2A

1F

CB-2

1C

2B

1D

1S

1Q

1P

CB-3

1M

1O1K

1J

1K1A

1E

1F

1G

1H

1I

CB-1

3B1

3L

6A

3G

3H 3C

5A

3A

3K

FP

STORAGE

UNISEX TOILET

ELEVATOR MACH RM

MED RM

TOILET

SUPPLY CLOSET

UNISEX TOILET

TOILET

EDUCATION RM COUNTRY ROAD

OFFICE

MAGIC CLINIC

MECH RM

INTAKE

PC

INTAKE

LINEN

SPD

DOCTORS

WORK RM

CONFERENCE RM

WHC EXAM

WHC EXAM 4TOILET

WHC EXAM

CLERKWHC

WAITING

INTAKE NURSEWHC EXAM

SOILED UTILITY

HAC

ELECTRIC

CLOSET

ELECTRICAL RM

STAIRWELL

HAC

KITCHEN

STORAGE

STORAGE

VESTIBULE

MECH RM

MED STUDENTS

2-BED RM

CORRIDOR

ELEVATOR

CORRIDORDUMB WAITER

TOILET

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

NC

N C

N C

N C

N C

NC

N C

NC

Z

Z

N C

Q

R

R.5

R.8

S

T

U

D

D

D

D

D D

DD

D

D D

D

D D

D

D

D

D

D

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:2

P

M

EYD-300

NURSE CALL - BUILDING 5 - BASEMENT

FLOOR - NURSE CALL DEMOLITION PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 5 - BASEMENT FLOOR - NURSE CALL DEMOLITION PLAN

SHEET NOTES:

1. AREA OF DEMOLITION. DEMOLISH ALL EXISTING NURSE CALL DEVICES AND CABLING IN THE AREAS OF

WORK. EXISTING CONDUITS AND OTHER RACEWAYS MAY BE MAINTAINED FOR REUSE WITH NEW DEVICES.

DEMOLISH ANY RACEWAYS NOT BEING REUSED.

ICE

MACH

BG-115A

CB-52

BG-115A

BG-131ACB-48

BG-124

CB-53

CB-8A

BF-101 BG-109

BG-100

BG-105

BG-107

BG-138

BG-117

BG-123

BG-125BG-116

BG-127BG-114

BG-112

BG-128

BG-129BG-111

BG-115D

BG-115C BG-115B

BG-115E

BG-115F

BG-115G

BG

BG-103 BG-104

BG-110

CB-43

BG-122

BG-126A

BG-126

BG-126D

CB-46

BG

126B

BG-126C

BG-131

BG-132

BG-139

BG-137

BG-135

BG-134

CB-47

BG-108 BG-136

BG-133BG-106

CB-49

BG-101

BG-102

CB-50

CB-51

FEC

CLEAN

LINEN

CORRIDOR

TOILET

MEDICINE RM

NURSE

STATION

PRIMARY

CARE

NURSE

CORRIDOR

WAITING RM

RECEPTION

WAITING RM

CONSULT RM POD EXAM

OFFICE

POD EXAM

POD EXAM

WAITING RM

TELECOM

LOUNGE EXAM/

TREATMENT

OFFICEOFFICE

EXAM/

TREATMENT

EXAM/

TREATMENT

EXAM /

TREATMENT

OFFICE

CLEAN

UTILITY

SOILED UTILITY

EXAM RM

EXAM RM EXAM RM

EXAM RM

EXAM RM

OFFICE

EXAM RM

ELECTRICAL OFFICE PROC RM

HAC

EXAM RM

CORRIDOR

EXAM RM

CORRIDOR

EXAM RM

OFFICE

OFFICE

OFFICE

ELECTRICAL

OFFICE

EXAM

EXAM

CORRIDOR

EXAM /

TREATMENT

EXAM /

TREATMENT

OFFICEOFFICE

CORRIDOR

NURSE

SOCIAL WORKER

CORRIDOR

CORRIDOR

CORRIDOR

FP

J J

D

N O P Q R

2.4

2.8

3.2

3.7

3.9

4.5

4.6

5.3

5.6

6.2

D

D

D

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:2

P

M

EYD-301

NURSE CALL - BUILDING 143 - BASEMENT

FLOOR - NURSE CALL DEMOLITION PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 143 - BASEMENT FLOOR - AREA A - NURSE CALL DEMOLITION PLAN

SHEET NOTES:

1. AREA OF DEMOLITION. DEMOLISH ALL EXISTING NURSE CALL DEVICES AND CABLING IN THE AREAS OF

WORK. EXISTING CONDUITS AND OTHER RACEWAYS MAY BE MAINTAINED FOR REUSE WITH NEW DEVICES.

CUBICAL WALL

BB-140

BB-162

BB-140A

BB-121

CB-29D

BC-100

BC-103

BC-105 BC-104

BC-107

BD-

BC-110

BC-118

BC-117B

BC-114

BC-122B

BC-123C

BC-122A

BC-123A

BC-127C

BC-127

BD-107A

BB-155

BC-103

BC-107A

BD-101

CB-29B

CB-29C

BC-122

CB-12

BC-102

BC-138

CB-24

BC-116

BB-146

BB-147

BB-150

CB-29ABC-125D

BB-154

BC-126JBC-126IBC-126HBC-126GBC-126F

BC-126E

CB-19

BB-141 BB-133

CB-14

CB-15

CB-16

BB-107

CB-17

CB-18

BB-100

BB-101

BB-112

BB-115

BB-116

BB-114

BB-113

BB-102

BB-165

BB-104

BB-137

CB-13A

CB-22

NO-5

CB-28

BB-153 BB-122

BB-123

BB-125

CB-20

BB-129BB-145

CB-21

BB-157 BB-152

BB-149

BB-153

BC-101

BC-101A

BC-109

BC-106

NO-1

BE-100

BD-100

BD-107

CB-27

BD-114C

BC-113

BC-111

BC-112

BC-115

BC-117A

BC-117

BC-121

BC-120BC-119

BD-114B

BD-108

BB-109

BB-105BB-136 BB-106

BB-108BB-134

BB-117BB-128

BB-119BB-126

BB-110BB-132

BB-111BB-130

BB-120BB-124BB-151

BB-127BB-148

BB-143 BB-131

BB-135

BB-139

BB-163

BB-161

BB-160

BB-159

BB-158

CB-23

BB-142

BB-138

BB-164

BC-127B

BC-127A

NO-4

BC-123B

BC-123

BC-124

BC-126

BC-125

BC-125KBC-125JBC-125IBC-125E

BC-125F

BC-125G

BC-125H

BC-125C BC-125B BC-125A

BC-126D

BC-126C BC-126B BC-126A

BC-122C

P-1

CB-13

BB-103

BC-108

CHUTE

TO BLDG 5

UP DN

DN

CLEAN

UTILITY

TELECOM

TELEPHONE

FP

TOILET

STORAGE

CORRIDOR

HAC

STORAGE

WHCH

TOILET

WHCH

TOILET

ARM AND LEG

WHRLP

FEMALE SHOWER/ LOCKER

TOILET

EQUIP / STRET

STORAGE WHCH

TOILET

WHCH TOILET

MALE

TELECOM

WOMENS TOILET

TOILET

MENS TOILET

STORAGEFP

HAC

SOIL

UTILITY

TOILET

SECY /

WAITING

MULTIPURPOSE

MULTIPURPOSE

DRESSING

HUBBARD

TANKS

BATTERY RECHARGE

CORRIDOR

WAITING

WAITING RM

STORAGE

BLDG

MGMT

CORRIDOR

OCCUPATIONAL

THERAPY

CASH

CART

TUMOR

REGISTRATION

EXAM /

TREATMENT

CORRIDOR

WORK RM

SECY

WORK RMEXAMEXAMEXAMEXAM

EXAM

TREAT

CORRIDOR

OFFICE OFFICE

WAITING RM

CORRIDOR

CORRIDOR

EXAM /

TREATMENT

CORRIDOR

NURSE STATION

TOILET

MALE

WOMENS TOILET

EXAM /

TREATMENT

OFFICE

SOCIAL WORKER

IT

SPECIALIST

OFFICE

OFFICE

ELECTRICAL

SVC BAY DIABETIC

CLASS RM

SVC BAY

STAIR

RECEPTION

CORRIDOR

STAIR

CORRIDOR

OFFICE OFFICE

EXAM /

TREATMENT

EXAM /

TREATMENT

CORRIDOR

SOCIAL WORKER

EXAM /

TREATMENT

CORRIDOR

CHIEF RMS

CLINICAL

DIETITIAN

OFFICE

ASST

CHIEF

CHIEF

MEN

TOILET

PHYS

THERAPY

TREATMENT

WORK AREA /

OFFICE

OFFICE

/ WORK

AREA

STAIR

TELE

ELECTRICAL

MALE

SHOWER

CORRIDOR

CHIEF

CORRECT

KINESLO

THERAPY

KT EQUIP

STORAGE

OFFICE

THERAPY

WAITING RM

OFFICE

KITCHEN

CLINIC

SPLINTING

EQUIP

STORE

ASST

CHIEF

OFFICE

COMPUTER

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

OFFICEOFFICE

CLEAN UTILITY

BIO

HAZARD

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

OFFICEEXAM /

TREATMENT

CLINICAL DIETITIAN

ELECTRICAL

SPEECH

PATHOLOGY

RMS

COORDINATION

PATIENT HEAD

CORRIDOR

HOUSE KEEPING

COPY RM

LOUNGE

SPEECH

PATHOLOGY

CLEAN LINEN

CLEAN SUPPLY

STAIR

MEDS

EDUCATION OFFICE

LOUNGE

NURSE STATION

NURSE STATION

EXAMEXAMEXAMPROCEDURE EXAM RM EXAM WORK RM

EXAM EXAM EXAM

WORK RM EXAM EXAM EXAM

RECEPTION

ELEVATOR

WAITING RM

MULTI PURPOSE

SHAFT

SHAFT

CORRIDOR

ELECTRICAL

NCNC

NC

Z

ZZ

Z

ZZ

J J J J J

J J J

J J J J J J J

JJJJ

NC

NC NC NC NC

NC NC NC NC

Z

NC

G H H.6 I J K L M N O P Q R R.5 R.8 S

8.2

8.6

9.3

11.3

14.5

E E E

EEEE

E E E E E E E

E E E E E

D D

D D

D

D

D D D

D D

D

D D

D

DDDD

DD

DD

DD

D

D D

D

D

D D

D

E

E

E E E E

E

E

E

EEEE

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:2

P

M

EYD-302

NURSE CALL - BUILDING 143 - BASEMENT

FLOOR - NURSE CALL DEMOLITION PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 143 - BASEMENT FLOOR - AREA B - NURSE CALL DEMOLITION PLAN

SHEET NOTES:

1. AREA OF DEMOLITION. DEMOLISH ALL EXISTING NURSE CALL

DEVICES AND CABLING IN THE AREAS OF WORK. EXISTING CONDUITS

AND OTHER RACEWAYS MAY BE MAINTAINED FOR REUSE WITH NEW

DEVICES. DEMOLISH ANY RACEWAYS NOT BEING REUSED.

2J-167

NO.

2H-108

2H-100

2H-110B2H-110A

2H-122A

2H-112A

2J-106A

2H-109

2H-134

2H-126

2H-129A

2H-127B

2J-178

2J-166A

2J-155

2J-152

2J-155B

2J-148 2J-168

2H-134B

2H-125A

2H-121C

2H-101

2J-155A

2H-135

2H-106D

2J-162

2H-116A

2H-114

C2-20

2H-133

2H-124

2H-1312H-116

C2-23

2H-113

2H-115

2H-110

C2-19

2H-102

2H-103

C2-24

C2-25

C2-21

2H-132 2H-130

2H-130A

2H-129 2H-128

2H-124A

2H-128A

2H-127A

2H-127

2H-125B

2H-125C

2H-122C

2H-123

2H-122B

C2-22

C2-24A

2H-121B

2H-120 2H-121A

2H-117A

2H-119 2H-118C

2H-118B

2H-118A 2H-118

2H-1172H-112

2J-157

2H-108 2H-107

2H-106C2H-106B

2J-106

2J-175

2J-176

2J-171

2J-172

2J-173

2J-166

C2-17

2J-153

2J-160

2J-154

2J-146

C2-16

C2-15

C2-14

C2-13

2J-177 2J-174

2J-1652J-164

2J-164A

2J-1612J-159

2J-158

2J-156A

2J-156

2J-153

2J-151

C2-18

P-3

S-3S-2S-1

2H-111

2J-179

ELECTRICAL

STAIR

TOILET

ACV

STORE

STR SHOWERWHCH TOILET

BATH

BATH

STORAGE

HAC

ANTE

RM

COMMON

CLOSET

BATH

CLOSET

INTAKE RM

STORAGE

BREAK

RM

NUTRI CTR

STAFF

TOILET

VISITORS TOILET SOILED LINEN

DUMB

WAITER - 2

BATH

BATH

BATH

STAFF TOILET

LOCKER

WAITING RM

EXAM

RM

SOILED

UTILITY

MED RM

PHYS ASST

CORRIDOR

CLEAN

UTILITY

PRE ADMIT

INT ROD

SOILED

UTILITYBREAK RM

OFFICE /

WORK RM

ELECTRICAL

ORTHO MD

OFFICE

CAST RM

COMM CTR / WARD CLK.

OFFICE

CODER

CORRIDOR

CORRIDOR

CORRIDOR

EXAM

RM - 1

MD / RN

WORK RM

BATH

EXAM RM -

EXAM RM - 1

CORRIDOR

EXAM RM

EXAM RM

EXAM RM -

PRE

ADMISSION

PRE

ADMISSION

EXAM RM

CLEAN LINEN

EXAM RM

CORRIDOR

CORRIDOR

EXAM RM

X-RAY

STORAGE EXAM RM

WAITING

RM EXAM

RM

EXAM

RM

EXAM RM

EXAM

RM

EXAM

RM

EXAM RMEXAM RM

1 -

BED RM

EXAM RM

EXAM RM

STORAGE

EXAM RMEXAM RM

EXAM RM

WAITING

CHECK-IN

EQUIP STORAGE

CAPD ED

TELE

PHARMACY

HAC

CLASS RM

CORRIDOR

CLEAN SUPPLY

CLEAN

UTILITY

NURSE MGR

CLINIC RN

CORRIDOR

NURSE STATION

CORRIDOR

CORRIDOR

H

BIOMED

MACH STOMACH STO

RE-USE RM

SET-UP

RM

6 - STATIONS

5 - STATIONS

BATH

1 - BED RM

CHIEF

RENAL

RESEARCH

CORRIDOR

S ELEVATOR LOBBY

SVC BAY

ORTHO EXAM RM

ELEVATOR ELEVATOR ELEVATOR

ELEVATOR

CG

DN

UP

DN

LOCKERS

NC NC NC

NC

N C

NC

NC

N C

Z

NC

Z

NCNC

NC

N C

N C

NC

N C

Z

NC

NC

NC

N C

N C

N C

N C

N C

NCNC

NC

N C

N C

N C

G H H.6 I J K L M N O P

1.3

2.4

2.8

3.2

3.7

3.9

4.5

4.6

5.3

5.6

6.2

6.7

6.8

D

D

D

D

D

D

D

DD

D

D

D

D

D

D

D

D

D

D D

D D

D

D

D

D

D

D

D

D

D

D

D D

D D

D

D

D

D

D

D

D

D

D

D

D

DDD

D

D

D

D

D

D

D

D

D

D

D

D

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:2

P

M

EYD-320

NURSE CALL - BUILDING 143 - SECOND FLOOR

- 2H - NURSE CALL DEMOLITION PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 143 - SECOND FLOOR - 2H - NURSE CALL DEMOLITION PLAN

SHEET NOTES:

1. AREA OF DEMOLITION. DEMOLISH ALL EXISTING NURSE CALL DEVICES AND CABLING IN THE AREAS OF

WORK. EXISTING CONDUITS AND OTHER RACEWAYS MAY BE MAINTAINED FOR REUSE WITH NEW DEVICES.

2J-118

NO. 1

2J-116A

2J-113A

2J-105B

2J-105

2J-104

2J-118B 2J-112

2J-111A

2J-108

2J-106

2J-137B

2J-124A

NO. 4

2J-135

2J-130A

2J-134A

2J-131A

2J-130

2J-107

2J-102B

2J-148 2J-168

2J-168

2J-100

2J-154

2J-146

C2-12

C2-132J-151

2J-150

2J-145

2J-147

2J-149

C2-2

C2-1

P-1

P-2

P-3

2J-170

S-3S-2S-1

C2-11

2J-102

2J-102A

2J-101

C2-3

2J-110

2J-118

2J-121

2J-1092J-123

C2-5

2J-141

2J-124

C2-4

C2-8

2J-122

2J-133

2J-140

2J-113

2J-111

2J-108B 2J-108A

2J-105A

2J-103

C2-8

2J-144

2J-143

2J-142 2J-142A

2J-138A

2J-1392J-138

2J-137A

2J-137

2J-138A

2J-138

2J-134C

C2-10

2J-134

2J-134B

2J-132

2J-131

2J-131C

2J-131B

2J-130C

2J-130B

C2-9

2J-114B

2J-114A

2J-114

2J-114C

C2-8A

2J-114D

2J-115

2J-116

2J-117

2J-120

2J-125

2J-1262J-127

2J-128A

2J-128

C2-7

2J-119

ELECTRICAL

WHCH

TOILET

STAIR

BATH

BATH

BATH

ANTE

RM

STORE

SHOWER

HAC

BATH

ANTE

RM

TELE

MED RM

STAIR

VACANT

BATH

CLOSET

BATH

BATH

ALCOVE

STAFF TOILET

TOILET

VISITORS TOILET SOILED LINEN

TRASH

MALE

TOILET

CLINIC RN

WAITING

RM

CORRIDOR

RENAL

RESEARCH

DR OFF

SECY

INTAKE

LOUNGE

VISITORS

LOUNGE

LOBBY

BLDG MNT

S ELEVATOR LOBBY

LOUNGE

FEMALE

LOCKER

FEMALE

TOILET

CORRIDOR

INTAKE

DERMATOLOGY

ELECTRICAL

TUMOR REG

NURSE

PRACT

CORRIDOR

CLEAN

UTILITY

NOUR STA

COMM CTR

STAFF WORK AREA

LOUNGE /

EDUCATION

INTAKE

SOILED UTILITY

EXAM RM

EXAM RM

BATH

EXAM RM

EXAM RM

WAITING RM

CORRIDOR

FILE RM

CLINIC

WALK-IN

INTAKE

/ TRIAGE

EXAM RM

BATH

EXAM RMWAITING

EXAM RM

EXAM

RM

EXAM

RM

EXAM

RM

RESIDENT EXAM RM

CORRIDOR

ALCOVE

EXAM RM

LINEN

CLOSET

ALCOVE

EXAM RM

EXAM RM

EXAM RM

EXAM RM

CORRIDOR

EXAM RM

EXAM RM

EXAM RM

EXAM RM

CORRIDOR

EXAM RM

EXAM RM

SCREENING

RM

OFFICE

EXAM RM

SCREENING

RM

EXAM RMEXAM RM

EXAM

RM

EXAM

RM

CORRIDOR

EXAM

RM

CORRIDOR

SVC BAY

ELEVATOR ELEVATOR ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

CG

UP

DN

DN

UP

DN

Z

Z

Z

N C

N C

NC

NC

N C

N C

N C

N C

N C

N C

NC

NC

NC

NC

NC

N C

NC

NC

NC

N C

NC

NC

NC

NC

NC

NC

NC

N C

N C

NC

NC

N C

N C

NC

NC

NC

NC

N C

N C

NC

NC NC NC NC

E F G H H.6 I J K L

6.7

6.8

7.5

8.2

8.6

9.3

11.3

D D

D

D

D

D

D

D

D

D

D

D

D D

D D

D

D

D

D

D D

D

D

D

DD

D

D

D

DD

D D

D

D D

D D

D

D

D

D

D

D

DD

D

D

D

D D

D

D

D D

D

DD

D

D

D

D D

D

D

D D

D

DD

DD

D

E E

EE

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:2

P

M

EYD-321

NURSE CALL - BUILDING 143 - SECOND FLOOR

- 2J - NURSE CALL DEMOLITION PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 143 - SECOND FLOOR - 2J - NURSE CALL DEMOLITION PLAN

SHEET NOTES:

1. AREA OF DEMOLITION. DEMOLISH ALL EXISTING NURSE CALL DEVICES AND CABLING IN THE AREAS OF

WORK. EXISTING CONDUITS AND OTHER RACEWAYS MAY BE MAINTAINED FOR REUSE WITH NEW DEVICES.

6.7

BATH

FEMALE TOILET

STAFF TOILETIRA

SHOWER

ELECTRICALBATH

STORAGE

BATH

ANTE RM

BATH

BATH

DIRTY LINEN RM

CLEAN

LINEN RM

BATH

BATH

BATH

MENS

TOILET

LINEN

CORRIDOR

CORRIDOR

LAUNDRY RM

BED RM

2 -

BED

RM

BED RM

BED RM

SUPPLY

BED RM

2 -

BED RM

BED RM

BED RM

BED RM

BED RM

BATH

BED RM

BED RM

BATH

BED RM

STAIR

MECH

EMS

MECH SHAFT

BED RM

BED RMOFFICEOFFICE

OFFICE

CLOSET

LOUNGE

NURSING STATION

KITCHEN

STORAGE SUPPLY

MED RM

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

DAY RM

OFFICE

OFFICE

CORRIDOR

BED RM

VISITOR LOUNGE

DAY RM

OXYGEN

STORAGE

CLEAN EQUIP RM

NURSING STATION

STAFF RM

COMPUTER RM

HOUSE KEEPING

OFFICE

SLEEP LABBATH

BED RMBED RMBED RMBED RM

BATH

OFFICEOFFICE

TELECOM

FOOD

STORAGE

OFFICECORRIDOR

LECTURE HALL

LECTURE HALL

CONFERENCE RM

STORAGE

OFFICE

OFFICE

ELECTRICAL

D N

3H-128A

3J-150

3H-1413H-139

3H-126A

3H-1163H-130A

3H-132

3H-108H

100A

3H-102A

3H-111A

3H-120

3H-113

3H-114A

3H-119A

3H-108A

3J-145

3J-154

C3-13

C3-12

3H-100A 3H-107

3H-108

3H-108B

3H-108C

3H-108E 3H-108D

3H-109

3H-111

3H-114

3H-119

3H-121

3H-121A 3H-122

3H-123

3H-123A

3H-124

NO - 3

3H-125

3H-127

3H-128

3H-1293H-1303H-130A

3H-130A 3H-130B

3J-151

C3-15

3H-103

3H-118

3H-117

C3-16

C3-17

C3-20

C3-21

3H-140

3H-138

3H-131

C3-18

3H-133

3H-137

3H-135

3H-134

3H-129A

C3-19

3H-115

3H-112

3H-105

3H-131

3H-1083H-104A

3H-1063H-1043H-1023H-101

100B

3J-1583J-157

3J-159

P-3

3J-160

3J-152C4-14

3J-149 3J-147

3J-146

3J-146A

3J-144

3J-144A S-1 S-2 S-3 3J-153

NORTH

NC

NC

NC

NC

N C

N C

NC

N C

NC

NC

N C

N C

N C

NC

NC

NC

N C

N C

N C

N C N C

N C

N C

N C

N C

N C

NC

N C

N C

Z

Z

Z

N C

NC

NC

N C

NC

N C

NC

N C

N C

G H H.6 I J K L M N O P

1.3

2.4

2.8

3.2

3.7

3.9

4.5

4.6

5.3

5.6

6.2

6.7

6.8

D

D

D

D

D

D

D

D

D D D

D

D

D

D D

D

D D D

D

D

D

D

D

D

D D

D

D

D

D

D

D

D

D

D

D

DD

D

D

D

D

D

D

D

D D

DD

D

D

D

DD

D

D

D D D D

D

D

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:2

P

M

EYD-330

NURSE CALL - BUILDING 143 - THIRD FLOOR -

3H - NURSE CALL DEMOLITION PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 143 - THIRD FLOOR - 3H - NURSE CALL DEMOLITION PLAN

SHEET NOTES:

1. AREA OF DEMOLITION. DEMOLISH ALL EXISTING NURSE CALL DEVICES AND CABLING IN THE AREAS OF

WORK. EXISTING CONDUITS AND OTHER RACEWAYS MAY BE MAINTAINED FOR REUSE WITH NEW DEVICES.

BATH

TELECOM

ELECTRICAL

BATH

LINEN

TRASH

BATH

BATH

BATH

BATH

STAFF TOILET

SHOWER

BATH

ANTE RM

STORAGE

STORAGE

BATH

BATH

COMM CLOSET

BATH

STORAGE

BATH

PAIN

CLINIC

LAUNDRY RM

CORRIDOR

CORRIDOR

X-RAY

2 - BED

PATIENT RM

BATH

2 - BED

PATIENT RM

GI

PROCEDURE

RM

PROCEDURE RM

WAITING AREA

STORAGE

OFFICE

OFFICE

SVC ELEVATOR LOBBY

ELECTRICAL

CORRIDOR

HOUSE

KEEPINGSTAIR

MENS

TOILET

WOMENS TOILET

RESEARCH

PROCEDURE RM

CORRIDOR

4 - BED

PATIENT RM

PATIENT RM

ANTE RM

CORRIDOR

CORRIDOR

OFFICE

EQUIP RM

NURSE

MGR

OFFICE

NEUROLOGY

PAIN

NURSE STATION

MED

RM

LOUNGE

DIETITIAN

SPD STORAGE

NURSE STATION

KITCHENSOILED UTILITY

VISITORS RM /

WAITING RM

BATH

PATIENT RM

BATH

PATIENT RMPATIENT RM

2 - BED

PATIENT RM

LINEN

STORAGE

4 - BED

PATIENT RM

4 - BED

PATIENT RM

OFFICE

EXAM /

TREATMENT RM

SVC BAY

MECH SHAFT

HOUSE

KEEPINGSTAIR

STORAGE

BATH

TREATMENT RM

2 - BED PATIENT RM

PROCEDURE RM

U P

U P

D N

D N

3J-114A

3J-105

3J-119

3J-112A

3J-154

3J-155

3J-103B

3J-107A

3J-110A

3J-104A

3J-106

3J-117B

3J-141A

3J-141 3J-142

3J-127

3J-128A

3J-129A

3J-133

3J-132A

3J-133

3J-125A

3J-132

C3-10

C3-9

3J-111

3J-135

3J-134A

3J-125

3J-112

3J-113

C3-1

P-3

3J-146A

3J-144

3J-144A S-1 S-2 S-3

C3-11

3J-153

P-3

C3-3

P-3

3J-156NO - 3

3J-1003J-1013J-102

3J-104

C3-5

3J-107

3J-104

3J-103

C3-6

C3-8

3J-108

3J-117

3J-109

3J-120

C3-7

3J-121A

3J-122

3J-130 3J-121

C3-4

3J-1403J-138

3J-143

3J-139A

3J-139

3J-136A

3J-1373J-136

3J-134

3J-131

3J-129

3J-128

3J-114

3J-115

3J-118

3J-116NO - 3

3J-123

3J-123A

3J-124

3J-126

3J-141A

N C

N C

N C

N C

N C

N C

N C

NC

NC

N C

N C

NC

N C

N C

NC NC

NC

N C

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

N C

N C

N C

NC

NC

NC N

C

NC

N C

NC

N C

N C

N C

N C N

C

N C

N C

NC

N C

N C N

C

NC

N C

NC

N C N

C

NC

NC

NC

NC

NC

N C

N C

N C

NC

NC

NC

ZZ

Z

NC NC

E F G H H.6 I J K L

6.7

6.8

7.5

8.2

8.6

9.3

11.3

D D D

D D

D

D D D

D

D

D

D

D

D

D

D

D

DD D D

D

D

D

D

D

D

D

D

D

D

D

D D

D

D

D

D

D

D

D

D

D

D D

D

D

D

D D

D

D

DD

D D

D D D

D

D

D

D D

D

D

D

D

D

D

D

D D

D

D

D D

D

D D

DDD

E E

EE

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:2

P

M

EYD-331

NURSE CALL - BUILDING 143 - THIRD FLOOR -

3J - NURSE CALL DEMOLITION PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 143 - THIRD FLOOR - 3J - NURSE CALL DEMOLITION PLAN

SHEET NOTES:

1. AREA OF DEMOLITION. DEMOLISH ALL EXISTING NURSE CALL DEVICES AND CABLING IN THE AREAS OF

WORK. EXISTING CONDUITS AND OTHER RACEWAYS MAY BE MAINTAINED FOR REUSE WITH NEW DEVICES.

DN

DN

SWING SPACE

PACT EXAM

PACT EXAM

2A

2I

2E

OFFICE

2D

GUEST/PATIENT

WiFi AREA

214 SF ±

PALMS

CASCADE FALLS

LILAC

GERANIUM

POPPY ROOM

HOLLY HOCK

CASCADE FALLS

WILLOW ROOM

HANDICAPPED RAMP

HANDICAPPED RAMP

HANDICAPPED RAMP

FP

UP

DN

DN

DN

UP

2J

2G

1R

1N

1L

1B

3E

CB-5

CB-4

2E 2F

2I2C

2A

1F

CB-2

1C

2B

1D

1S

1Q

1P

CB-3

1M

1O1K

1J

1K1A

1E

1F

1G

1H

1I

CB-1

3B1

3L

6A

3G

3H

3D

3C

5A

3A

3K

FP

STORAGE

UNISEX TOILET

ELEVATOR MACH RM

MED RM

TOILET

SUPPLY CLOSET

UNISEX TOILET

TOILET

EDUCATION RM COUNTRY ROAD

OFFICE

MAGIC CLINIC

MECH RM

INTAKE

PC

INTAKE

LINEN

SPD

DOCTORS

WORK RM

CONFERENCE RM

WHC EXAM

WHC EXAM 4TOILET

WHC EXAM

CLERKWHC

WAITING

INTAKE NURSEWHC EXAM

SOILED UTILITY

HAC

ELECTRIC

CLOSET

ELECTRICAL RM

STAIRWELL

HAC

KITCHEN

STORAGE

STORAGE

STORAGE

VESTIBULE

MECH RM

MED STUDENTS

2-BED RM

CORRIDOR

ELEVATOR

CORRIDORDUMB WAITER

TOILET

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

NC

NC

NCNC

N C

NC

N C

N C

N C

NC

Z

Z

NC

N C

NC NC

NC

NC

NC

NC

NCNC

NC

N C

NC

N C

N C

NC

N C

NC

NC

NC

N C

N C

N C

N C

NC NC

N C

N C

NC NC

Q

R

R.5

R.8

S

T

U

D

D D

TERM-4B

STATUSTERM-4B

STATUS

APULL

APULL

APULL

TERM-4B

STATUS

D

TERM-4B

STATUS

D D

TERM-4B

STATUS

TERM-4B

STATUS

D

D

APULL

APULL

RAUD

TERM-4B

CODE STF

CONS 1

CONS 2

CONS 3

TERM-4B

STATUS D

RAUDRAUD

RAUD

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

STF

STF

STF

TERM-4B

STATUS

RAUD

RAUD

RAUD

STF STF

RAUD

STF STF

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE TERM-4B

CODE

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:0

P

M

EY-300

NURSE CALL - BUILDING 5 - BASEMENT

FLOOR - NURSE CALL NEW PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 5 - BASEMENT FLOOR - NURSE CALL NEW PLAN

1. DEDUCT ALTERNATE 1: DO NOT PROVIDE AUDIO CAPABILITY. DO NOT PROVIDE REMOTE

AUDIO STATIONS. ALL OTHER STATIONS INDICATED TO BE TONE/VISUAL VERSION OF

STATION SHOWN. BASE BID INCLUDES AUDIO/VISUAL STATIONS AS SHOWN.

ALTERNATES:

ICE

MACH

BG-115A

CB-52

BG-115A

BG-131ACB-48

BG-124

CB-53

CB-8A

BF-101 BG-109

BG-100

BG-105

BG-107

BG-138

BG-117

BG-123

BG-125BG-116

BG-127BG-114

BG-112

BG-128

BG-129BG-111

BG-115D

BG-115C BG-115B

BG-115E

BG-115F

BG-115G

BG

BG-103 BG-104

BG-110

CB-43

BG-122

BG-126A

BG-126

BG-126D

CB-46

BG

126B

BG-126C

BG-131

BG-132

BG-139

BG-137

BG-135

BG-134

CB-47

BG-108 BG-136

BG-133BG-106

CB-49

BG-101

BG-102

CB-50

CB-51

FEC

CLEAN

LINEN

CORRIDOR

TOILET

MEDICINE RM

NURSE

STATION

PRIMARY

CARE

NURSE

CORRIDOR

WAITING RM

RECEPTION

WAITING RM

CONSULT RM POD EXAM

OFFICE

POD EXAM

POD EXAM

WAITING RM

TELECOM

LOUNGE EXAM/

TREATMENT

OFFICEOFFICE

EXAM/

TREATMENT

EXAM/

TREATMENT

EXAM /

TREATMENT

OFFICE

CLEAN

UTILITY

SOILED UTILITY

EXAM RM

EXAM RM EXAM RM

EXAM RM

EXAM RM

OFFICE

EXAM RM

ELECTRICAL OFFICE PROC RM

HAC

EXAM RM

CORRIDOR

EXAM RM

CORRIDOR

EXAM RM

OFFICE

OFFICE

OFFICE

ELECTRICAL

OFFICE

EXAM

EXAM

CORRIDOR

EXAM /

TREATMENT

EXAM /

TREATMENT

OFFICEOFFICE

CORRIDOR

NURSE

SOCIAL WORKER

CORRIDOR

CORRIDOR

CORRIDOR

FP

NC

N C

N C

N

CN

C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N

CN

C N

C

N C

NC

N C

N C

N C

N C

N C

N C

N C

NC

N C

NC

NC

NC

N C

NC

NC

NC NC

N C

N C

N C

N C

NC NC

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

NCNC

NC

NC

NC

NCNC

NC

N C

NC NCNCNC

N C

NC

N C

N O P Q R

2.4

2.8

3.2

3.7

3.9

4.5

4.6

5.3

5.6

6.2

CONS 1

CONS 2

D

D D

D

D

D

D

D

D

D

D

DD

D

D

D

D

D

D

RAUD

TERM-4B

CODE

RAUD

STF

TERM-4B

CODE

STFSTF

TERM-4B

CODE

STF

TERM-4B

CODE

RAUD

RAUD

TERM-4B

CODE

STF

RAUD

TERM-4B

CODE

STF

RAUD

STF

TERM-4B

CODE

RAUD

RAUD

RAUD

TERM-4B

CODE

STF

STF

TERM-4B

CODE

RAUD

RAUD

STF

TERM-4B

CODE

TERM-4B

CODE

STF

RAUD

RAUD

RAUDRAUD

RAUD

STF

TERM-4B

CODE

STF

TERM-4B

CODE

STF

TERM-4B

CODESTFTERM-4B

CODE

STF

TERM-4B

CODE

RAUD

RAUD

RAUD

RAUD

RAUD

RAUDRAUD

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

STF STF

TERM-4B

CODE

TERM-4B

CODE

STF STF

STF STF

STF

STF

RAUD

RAUD

RAUD

RAUD RAUD

STF TERM-4B

CODE

TERM-4B

CODE

STF

TERM-4B

CODE

STF TERM-4B

CODE

STF TERM-4B

CODE

APULL

D

1 1

1 1

1 1

1 1

DDD

D

D

D

D

D

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:0

P

M

EY-301

NURSE CALL - BUILDING 143 - BASEMENT

FLOOR - NURSE CALL NEW PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 143 - BASEMENT FLOOR - AREA A - NURSE CALL NEW PLAN

SHEET NOTES:

1. EXTENTS OF CLINIC. NURSE CALL DEVICES WITHIN CLINIC TO ANNUNCIATE IN CLINIC BEFORE

ESCALATING TO ATTENDED LOCATION.

1. DEDUCT ALTERNATE 1: DO NOT PROVIDE AUDIO CAPABILITY. DO NOT PROVIDE REMOTE

AUDIO STATIONS. ALL OTHER STATIONS INDICATED TO BE TONE/VISUAL VERSION OF

STATION SHOWN. BASE BID INCLUDES AUDIO/VISUAL STATIONS AS SHOWN.

CUBICAL WALL

BB-140

BB-162

BB-140A

BB-121

CB-29D

BC-100

BC-103

BC-105 BC-104

BC-107

BD-

BC-110

BC-118

BC-117B

BC-114

BC-122B

BC-123C

BC-122A

BC-123A

BC-127C

BC-127

BD-107A

BB-155

BC-103

BC-107A

BD-101

CB-29B

CB-29C

BC-122

CB-12

BC-102

BC-138

CB-24

BC-116

BB-146

BB-147

BB-150

CB-29ABC-125D

BB-154

BC-126JBC-126IBC-126HBC-126GBC-126F

BC-126E

CB-19

BB-141 BB-133

CB-14

CB-15

CB-16

BB-107

CB-17

CB-18

BB-100

BB-101

BB-112

BB-115

BB-116

BB-114

BB-113

BB-102

BB-165

BB-104

BB-137

CB-13A

CB-22

NO-5

CB-28

BB-153 BB-122

BB-123

BB-125

CB-20

BB-129BB-145

CB-21

BB-157 BB-152

BB-149

BB-153

BC-101

BC-101A

BC-109

BC-106

NO-1

BE-100

BD-100

BD-107

CB-27

BD-114C

BC-113

BC-111

BC-112

BC-115

BC-117A

BC-117

BC-121

BC-120BC-119

BD-114B

BD-108

BB-109

BB-105BB-136 BB-106

BB-108BB-134

BB-117BB-128

BB-119BB-126

BB-110BB-132

BB-111BB-130

BB-120BB-124BB-151

BB-127BB-148

BB-143 BB-131

BB-135

BB-139

BB-163

BB-161

BB-160

BB-159

BB-158

CB-23

BB-142

BB-138

BB-164

BC-127B

BC-127A

NO-4

BC-123B

BC-123

BC-124

BC-126

BC-125

BC-125KBC-125JBC-125IBC-125E

BC-125F

BC-125G

BC-125H

BC-125C BC-125B BC-125A

BC-126D

BC-126C BC-126B BC-126A

BC-122C

P-1

CB-13

BB-103

BC-108

CHUTE

UP DN

DN

CLEAN

UTILITY

TELECOM

TELEPHONE

FP

TOILET

STORAGE

CORRIDOR

HAC

STORAGE

WHCH

TOILET

WHCH

TOILET

ARM AND LEG

WHRLP

FEMALE SHOWER/ LOCKER

TOILET

EQUIP / STRET

STORAGE WHCH

TOILET

WHCH TOILET

MALE

TELECOM

WOMENS TOILET

TOILET

MENS TOILET

STORAGEFP

HAC

SOIL

UTILITY

TOILET

SECY /

WAITING

MULTIPURPOSE

MULTIPURPOSE

DRESSING

HUBBARD

TANKS

BATTERY RECHARGE

CORRIDOR

WAITING

WAITING RM

STORAGE

BLDG

MGMT

CORRIDOR

OCCUPATIONAL

THERAPY

CASH

CART

TUMOR

REGISTRATION

EXAM /

TREATMENT

CORRIDOR

WORK RM

SECY

WORK RMEXAMEXAMEXAMEXAM

EXAM

TREAT

CORRIDOR

OFFICE OFFICE

WAITING RM

CORRIDOR

CORRIDOR

EXAM /

TREATMENT

CORRIDOR

NURSE STATION

TOILET

MALE

WOMENS TOILET

EXAM /

TREATMENT

OFFICE

SOCIAL WORKER

IT

SPECIALIST

OFFICE

OFFICE

ELECTRICAL

SVC BAY DIABETIC

CLASS RM

SVC BAY

STAIR

RECEPTION

CORRIDOR

STAIR

CORRIDOR

OFFICE OFFICE

EXAM /

TREATMENT

EXAM /

TREATMENT

CORRIDOR

SOCIAL WORKER

EXAM /

TREATMENT

CORRIDOR

CHIEF RMS

CLINICAL

DIETITIAN

OFFICE

ASST

CHIEF

CHIEF

MEN

TOILET

PHYS

THERAPY

TREATMENT

WORK AREA /

OFFICE

OFFICE

/ WORK

AREA

STAIR

TELE

ELECTRICAL

MALE

SHOWER

CORRIDOR

CHIEF

CORRECT

KINESLO

THERAPY

KT EQUIP

STORAGE

OFFICE

THERAPY

WAITING RM

OFFICE

KITCHEN

CLINIC

SPLINTING

EQUIP

STORE

ASST

CHIEF

OFFICE

COMPUTER

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

OFFICEOFFICE

CLEAN UTILITY

BIO

HAZARD

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM /

TREATMENT

OFFICEEXAM /

TREATMENT

CLINICAL DIETITIAN

ELECTRICAL

SPEECH

PATHOLOGY

RMS

COORDINATION

PATIENT HEAD

CORRIDOR

HOUSE KEEPING

COPY RM

LOUNGE

SPEECH

PATHOLOGY

CLEAN LINEN

CLEAN SUPPLY

STAIR

MEDS

EDUCATION OFFICE

LOUNGE

NURSE STATION

NURSE STATION

EXAMEXAMEXAMPROCEDURE EXAM RM EXAM WORK RM

EXAM EXAM EXAM

WORK RM EXAM EXAM EXAM

RECEPTION

ELEVATOR

WAITING RM

MULTI PURPOSE

SHAFT

SHAFT

CORRIDOR

ELECTRICAL

N C

N C

N C

N C

NC NC

N

CN

C N

C

N C

NC

N C

N C

N C

NCNC

N C

N C

N C

NC NC

N C

NC NC NC NCNCNC

N C

NC

N C

NC

N C

NC

N C

NCNC

N C

NC

N C

NC

N C

NC

NC NC NC NC

NCNCNCNCNC

NC NC NCNC

NC

NC NC NC NC NC NC NC

N C

N C

N C

NC

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

NCNC

N C

N C

N C

N C

N C

N C

NC NC

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

N C

NC NC

N C

N C

N C

N C

NC NC

NC NC

NC NC NC NC

NC NC NC NC

Z

NC

NC

N C

NC

N C

N C

G H H.6 I J K L M N O P Q R R.5 R.8 S

8.2

8.6

9.3

11.3

14.5

TERM-4B

CODE

STF STF

TERM-4B

CODE

STF

TERM-4B

CODE

APULL

APULLAPULL

D

D

D

DDDDDDD

D D D D

D

D D

D D

D D

D D D

TERM-4B

CODE

STF

TERM-4B

CODE

STF

TERM-4B

CODE

STF

STF

TERM-4B

CODE

TERM-4B

CODE

STFSTF

TERM-4B

CODE

STF

TERM-4B

CODE STF

TERM-4B

CODE

TERM-4B

CODE

STF

TERM-4B

CODESTF

TERM-4B

CODE

STF

TERM-4B

CODE

STF

STF

TERM-4B

CODE

TERM-4B

CODE

STF

TERM-4B

CODE

STF

TERM-4B

CODE

STF

TERM-4B

CODE

STF

NCC

1 1 1 1

11111

1 1 11

APULL

RAUD

1 1 1 1 1 1

RAUD RAUD RAUD RAUD RAUD RAUD

RAUD

RAUD

RAUDRAUD

RAUD RAUD RAUD RAUD

RAUDRAUD

RAUDRAUDRAUD

D

D D

D D

D D

D D

RAUD RAUD

RAUD RAUD

RAUD

RAUD

RAUD

RAUD

D

D

D D

D

D D

D

D

D

D

DD

D

D

D D D

STF STF

STFSTF

STF STF

TERM-4B

CODE

STFSTF

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

RAUD

RAUD

RAUD

RAUD

RAUD

RAUD

RAUD

RAUD

RAUD

RAUDRAUD

RAUD

RAUD RAUD

RAUD

RAUD

RAUD

RAUD

RAUDRAUDRAUD

STF STF

STF STF

STF STF

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

STFSTF

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

STFSTF

TERM-4B

CODE

STF STF

TERM-4B

CODE

TERM-4B

CODE

STF STF

STF STF

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

TERM-4B

CODE

STF

TERM-4B

CODE

STF

TERM-4B

CODE

TERM-4B

CODE

STF

STF

TERM-4B

CODE

STF

TERM-4B

CODE

E

E

EEEE

E E E E E

E

E

PULL PULL PULL PULL

D

D

PULLPULLPULLPULL

1 1

1 1

1 1

1 1 1

1 1 1 1 1

1 1 1

1 1 1

1 1

CONS 1

CONS 2

CONS 1

CONS 2

APULL

1D

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:1

P

M

EY-302

NURSE CALL - BUILDING 143 - BASEMENT

FLOOR - NURSE CALL NEW PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 143 - BASEMENT FLOOR - AREA B - NURSE CALL NEW PLAN

SHEET NOTES:

1. INSTALL NEW NURSECALL DEVICE IN EXISTING WALL BOX IN

APPROXIMATE LOCAITON SHOWN. REUSE EXISTING WALL BOX

AND CONDUIT TO ABOVE CEILING. PROVIDE NEW DEVICE AND

NEW CABLING.

2. EXTENTS OF CLINIC. NURSE CALL DEVICES WITHIN CLINIC TO

ANNUNCIATE IN CLINIC BEFORE ESCALATING TO ATTENDED

LOCATION.

1. DEDUCT ALTERNATE 1: DO NOT PROVIDE AUDIO CAPABILITY.

DO NOT PROVIDE REMOTE AUDIO STATIONS. ALL OTHER

STATIONS INDICATED TO BE TONE/VISUAL VERSION OF

STATION SHOWN. BASE BID INCLUDES AUDIO/VISUAL STATIONS

AS SHOWN.

NO.

2H-108

2H-100

2H-110B2H-110A

2H-122A

2H-112A

2J-106A

2H-109

2H-134

2H-126

2H-129A

2H-127B

2J-178

2J-166A

2J-155

2J-152

2J-155B

2H-134B

2H-125A

2H-121C

2H-101

2J-155A

2H-135

2H-106D

2J-162

2H-116A

2H-114

C2-20

2H-133

2H-124

2H-1312H-116

C2-23

2H-113

2H-115

2H-110

C2-19

2H-102

2H-103

C2-24

C2-25

C2-21

2H-132 2H-130

2H-130A

2H-129 2H-128

2H-124A

2H-128A

2H-127A

2H-127

2H-125B

2H-125C

2H-122C

2H-123

2H-122B

C2-22

C2-24A

2H-121B

2H-120 2H-121A

2H-117A

2H-119 2H-118C

2H-118B

2H-118A 2H-118

2H-1172H-112

2J-157

2H-108 2H-107

2H-106C2H-106B

2J-106

2J-175

2J-176

2J-171

2J-172

2J-173

2J-166

C2-17

2J-153

2J-160

2J-154

2J-146

C2-16

C2-15

C2-14

C2-13

2J-177 2J-174

2J-1652J-164

2J-164A

2J-1612J-159

2J-158

2J-156A

2J-156

2J-153

2J-151

C2-18

P-3

S-3S-2S-1

2H-111

2J-179

ELECTRICAL

STAIR

TOILET

ACV

STORE

STR SHOWERWHCH TOILET

BATH

BATH

STORAGE

HAC

ANTE

RM

COMMON

CLOSET

BATH

CLOSET

INTAKE RM

STORAGE

BREAK

RM

NUTRI CTR

STAFF

TOILET

DUMB

WAITER - 2

BATH

BATH

BATH

STAFF TOILET

LOCKER

WAITING RM

EXAM

RM

SOILED

UTILITY

MED RM

PHYS ASST

CORRIDOR

CLEAN

UTILITY

PRE ADMIT

INT ROD

SOILED

UTILITYBREAK RM

OFFICE /

WORK RM

ELECTRICAL

ORTHO MD

OFFICE

CAST RM

COMM CTR / WARD CLK.

OFFICE

CODER

CORRIDOR

CORRIDOR

CORRIDOR

EXAM

RM - 1

MD / RN

WORK RM

BATH

EXAM RM -

EXAM RM - 1

CORRIDOR

EXAM RM

EXAM RM

EXAM RM -

PRE

ADMISSION

PRE

ADMISSION

EXAM RM

CLEAN LINEN

EXAM RM

CORRIDOR

CORRIDOR

EXAM RM

X-RAY

STORAGE EXAM RM

WAITING

RM EXAM

RM

EXAM

RM

EXAM RM

EXAM

RM

EXAM

RM

EXAM RMEXAM RM

1 -

BED RM

EXAM RM

EXAM RM

STORAGE

EXAM RMEXAM RM

EXAM RM

WAITING

CHECK-IN

EQUIP STORAGE

CAPD ED

TELE

PHARMACY

HAC

CLASS RM

CORRIDOR

CLEAN SUPPLY

CLEAN

UTILITY

NURSE MGR

CLINIC RN

CORRIDOR

NURSE STATION

CORRIDOR

CORRIDOR

H

BIOMED

MACH STOMACH STO

RE-USE RM

SET-UP

RM

6 - STATIONS

5 - STATIONS

BATH

1 - BED RM

CHIEF

RENAL

RESEARCH

CORRIDOR

SVC BAY

ORTHO EXAM RM

ELEVATOR ELEVATOR ELEVATOR

ELEVATOR

CG

DN

UP

DN

LOCKERS

NORTH

NC

NC

NCNC

N C

NC

N C

N C

N C

NC

NC

NC

NC

N C

N C

NC

N C

N C

NCNC

NC

N C

N C

N C

N C

NC

N C

N C

N C N

C

NC

NC

N C

NC

NC

NC

NC

NC

N C

N C

N C

N C

NC

NC

NC

NC

NC

NC

N C

N C

N C

N C

N C

N C

N C

ZZ

ZZ

G H H.6 I J K L M N O P

1.3

2.4

2.8

3.2

3.7

3.9

4.5

4.6

5.3

5.6

6.2

6.7

6.8

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

D D

D

D

D

APULL

DD

D

D

TERM-4B

STF/CODE

APULL

PULL

CONS

D

APULL

PULL

TERM-4B

STF/CODE

2BSID-PLW

TERM-4B

STF/CODE

D

TERM-4B

STF/CODE

TERM-4B

STF/CODE

DD

D D

TERM-4B

STF/CODE

TERM-4B

STF/CODE

2BSID-PLW

TERM-4B

STF/CODE

2BSID-PLW

2BSID-PLW

TERM-4B

STF/CODE

TERM-4B

STF/CODE

APULL

APULL

PULL

D

D

D

APULL

PULL

2BSID-PLW

2BSID-PLW

TERM-4B

STF/CODE

TERM-4B

STF/CODE

D

TERM-4B

STF/CODE 2BSID-PLW

D

TERM-4B

STF/CODE

D

D

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

D

CONS

PULL

APULL

APULLPULL

D D

D

BSID-PLW

TERM-4B

STF/CODE

TERM-4B

STF/CODE

BSID-PLW

TERM-4B

STF/CODE

BSID-PLW

TERM-4B

STF/CODE

3 1 1

1 2

1 2

3 1 2

3 1 21

3 1 2

21 1 2 1 2

PULLAPULL

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 21450.001 06/16/2023 21451.001

DWG of 17

1/8" = 1'-0"

B

IM

/2

.0

S a le m V

A R e p la c e N u rs e C a ll/

.0

S a le m

V A

R e p la c e

N u rs e C a ll_

S E

S

.r v t

/1

/2

:2

:1

P

M

EY-320

NURSE CALL - BUILDING 143 - SECOND FLOOR

- 2H - NURSE CALL NEW PLAN

REPLACE NURSE CALL

658-22-101

1970 Roanoke Blvd, Salem, VA 24153

06/16/2023 NMT NMT

1/8" = 1'-0"

NURSE CALL - BUILDING 143 - SECOND FLOOR - 2H - NURSE CALL NEW PLAN

SHEET NOTES:

1. EXTENTS OF CLINIC. NURSE CALL DEVICES WITHIN CLINIC TO

ANNUNCIATE IN CLINIC BEFORE ESCALATING TO ATTENDED

LOCATION.

1. DEDUCT ALTERNATE 1: DO NOT PROVIDE AUDIO CAPABILITY.

DO NOT PROVIDE REMOTE AUDIO STATIONS. ALL OTHER

STATIONS INDICATED TO BE TONE/VISUAL VERSION OF

STATION SHOWN. BASE BID INCLUDES AUDIO/VISUAL STATIONS

AS SHOWN.

2. DEDUCT ALTERNATE 2: DO NOT PROVIDE BEDSIDE PATIENT

STATION. BASE BID INCLUDES THESE STATIONS.

3. DEDUCT ALTERNATE 3: DO NOT PROVIDE4-BUTTON STATIONS

INDICATED. BASE BID INCLUDES THESE STATIONS.

2J-118

NO. 1

2J-116A

2J-113A

2J-105B

2J-105

2J-104

2J-118B 2J-112

2J-111A

2J-108

2J-106

2J-137B

2J-124A

NO. 4

2J-135

2J-130A

2J-134A

2J-131A

2J-130

2J-107

2J-102B

2J-148 2J-168

2J-168

2J-100

2J-154

2J-146

C2-12

C2-132J-151

2J-150

2J-145

2J-147

2J-149

C2-2

C2-1

P-1

P-2

P-3

2J-170

S-3S-2S-1

C2-11

2J-102

2J-102A

2J-101

C2-3

2J-110

2J-118

2J-121

2J-1092J-123

C2-5

2J-141

2J-124

C2-4

C2-8

2J-122

2J-133

2J-140

2J-113

2J-111

2J-108B 2J-108A

2J-105A

2J-103

C2-8

2J-144

2J-143

2J-142 2J-142A

2J-138A

2J-1392J-138

2J-137A

2J-137

2J-138A

2J-138

2J-134C

C2-10

2J-134

2J-134B

2J-132

2J-131

2J-131C

2J-131B

2J-130C

2J-130B

C2-9

2J-114B

2J-114A

2J-114

2J-114C

C2-8A

2J-114D

2J-115

2J-116

2J-117

2J-120

2J-125

2J-1262J-127

2J-128A

2J-128

C2-7

2J-119

ELECTRICAL

WHCH

TOILET

STAIR

BATH

BATH

BATH

ANTE

RM

STORE

SHOWER

HAC

BATH

ANTE

RM

TELE

MED RM

STAIR

VACANT

BATH

CLOSET

BATH

BATH

ALCOVE

STAFF TOILET

TOILET

VISITORS TOILET SOILED LINEN

TRASH

MALE

TOILET

CLINIC RN

WAITING

RM

CORRIDOR

RENAL

RESEARCH

DR OFF

SECY

INTAKE

LOUNGE

VISITORS

LOUNGE

LOBBY

BLDG MNT

S ELEVATOR LOBBY

LOUNGE

FEMALE

LOCKER

FEMALE

TOILET

CORRIDOR

INTAKE

DERMATOLOGY

ELECTRICAL

TUMOR REG

NURSE

PRACT

CORRIDOR

CLEAN

UTILITY

NOUR STA

COMM CTR

STAFF WORK AREA

LOUNGE /

EDUCATION

INTAKE

SOILED UTILITY

EXAM RM

EXAM RM

BATH

EXAM RM

EXAM RM

WAITING RM

CORRIDOR

FILE RM

CLINIC

WALK-IN

INTAKE

/ TRIAGE

EXAM RM

BATH

EXAM RMWAITING

EXAM RM

EXAM

RM

EXAM

RM

EXAM

RM

RESIDENT EXAM RM

CORRIDOR

ALCOVE

EXAM RM

LINEN

CLOSET

ALCOVE

EXAM RM

EXAM RM

EXAM RM

EXAM RM

CORRIDOR

EXAM RM

EXAM RM

EXAM RM

EXAM RM

CORRIDOR

EXAM RM

EXAM RM

SCREENING

RM

OFFICE

EXAM RM

SCREENING

RM

EXAM RMEXAM RM

EXAM

RM

EXAM

RM

CORRIDOR

EXAM

RM

CORRIDOR

SVC BAY

ELEVATOR ELEVATOR ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

CG

UP

DN

DN

UP

DN

NC

NC

NC

N C

N C

N C

N C

NC

N C

NC

NC

N C

N C

N C

N C

N C

N C

NC

NC

NC

NC

NC

NC

NC

NC

NC

N C

N C

NC

NC

NC

N C

NC

NC

NC

Z

Z Z

NC

NC

N C

N C

NC

NC

NC

NC

N C

N C

N C

NC

NC

NC

NC

NC

N C

N C

N C

NC NC NC NC

Z

E F G H H.6 I J K L

6.7

6.8

7.5

8.2

8.6

9.3

11.3

D

D

D

TERM-4B

STF/CODE

TERM-4B

STF/CODE

D

TERM-4B

STF/CODE

D

TERM-4B

STF/CODE

D

2BSID-PLW

2BSID-PLW

PULL

APULL

D

D

TERM-4B

STF/CODE

TERM-4B

STF/CODE

D

D

TERM-4B

STF/CODE

TERM-4B

STF/CODE

APULL PULL

D

BSID-PLW

D

PULL

APULL

2BSID-PLW

2BSID-PLW

D

PULL

APULL

APULL

PULL

D

PULL

APULL

APULL

PULL

2BSID-PLW

D

APULL

PULL

PULL

D

D

BSID-PLW

PULL

APULL

D

D

D

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

D

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

DD

D

D

D

D

D

TERM-4B

STF/CODE

CONS

TERM-4B

STF/CODE

TERM-4B

STF/CODE

TERM-4B

STF/CODE

CONS

TERM-4B

STF/CODE

TERM-4B

STF/CODE

D D

TERM-4B

STF/CODE

E E

EE

D D

PULLPULL

1 2

1 23

3 1 2

1 2

1 2 3

Scale:

2A

KEY PLAN

TRUE NORTHPLAN NORTH

Drawing File Number

Building Number

Drawing Number

Project Title / Project Number

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .