Drawings.pdf
PDF 29 MB Posted
- Attached to
- 3910--Pneumatic Tubes Campus Wide Salisbury VAMC
- Solicitation number
- 36C24623B0030
About this file
This document provides details for a federal solicitation notice seeking bids for a pneumatic tubes campus wide project at the Salisbury VAMC. The Department of Veterans Affairs is soliciting bids from contractors to provide all labor, materials, equipment, and services necessary to design, produce, and expand an existing pneumatic tube system across five buildings on the VA medical center campus in Salisbury, North Carolina. The project scope includes installing pneumatic tube pathways and associated equipment, millwork, carpentry, painting, plumbing, HVAC, fire suppression, electrical, and communications systems. All work must be completed within 210 calendar days of receiving a notice to proceed and shall comply with provided specifications and drawings. The contractor will also provide user training, maintenance training, and a train the trainer program. The estimated construction value is between $2,000,000 and $5,000,000. Bids are due by March 23, 2023 and the solicitation is anticipated to be a total service-disabled veteran owned small business set-aside.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24623B0030 0003.docx | DOCX document | |
| 36C24623B0030 0002.docx | DOCX document | |
| 36C24623B0030 0001.docx | DOCX document | |
| 659-22-202_SOW_20221115.pdf | ||
| 36C24623B0030_1.docx | DOCX document | |
| Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
659-22-202
I
A
F
H
G
E
PEDS WALKWAY
PEDS WALKWAY
11/16/22
GROUND FLOOR - BUILDING 20
FIRST FLOOR - BUILDING 20
SECOND FLOOR - BUILDING 20
GROUND FLOOR - BUILDING 21
FIRST FLOOR - BUILDING 21
FIRST FLOOR - BUILDING 43
TO BLDG. #2
TO BLDG. #5
SET SCREW WITH
LOCKNUT
MINIMUM ROD
INSERTION IS 1/2"
NOTES:
1. SUBSTITUTE BEAM CLAMP WHERE REQUIRED TO ANCHOR TO BEAMS, IN
LIEU OF ANCHORS THROUGH CONCRETE.
2. SET SCREW MUST BE TIGHTENED ONTO THE SLOPED SIDE OF THE I-BEAM,
CHANNEL OR ANGLE IRON FLANGE
JOINT INSTALLATION NOTES
• ENSURE TUBING JOINTS ARE STRAIGHT AND PROVIDE A GOOD SEAL. GAPS BETWEEN PIECES OF TUBING INDICATE THE TUBING IS NOT POSITIONED PROPERLY, AND CAN CAUSE THE OTHER END TO BE OUT OF ALIGNMENT OR CAN CAUSE CARRIERS TO BECOME
LODGED.
• ENSURE ALL JOINTS ARE PARALLEL AND COMPLETELY STRAIGHT, AND NO EDGES REMAIN THAT MAY DAMAGE CARRIERS OR
INTERFERE IN ANY WAY WITH CARRIER TRAVEL.
• REMOVE ANY BURRS FROM THE ENDS OF THE TUBING WITH A FILE.
• IF FLARING IS REQUIRED FOR A JOINT, ENSURE THE FLARE IS PREPARED BEFORE THE INSTALLATION.
• DRY-FIT EACH JOINT BEFORE APPLYING ADHESIVES OR TAPE, AND MARK THE POINT WHERE THE JOINT IS PROPERLY SEATED. IF A BOLTED COUPLING OR DRIVE SLEEVE IS USED, MARK THE LOCATION OF EITHER END OF THE COUPLING OR SLEEVE TO ENSURE THE
JOINT IS PROPERLY CENTERED.
• APPLY ADHESIVES PER MANUFACTURER INSTRUCTIONS. OBSERVE ALL WARNINGS AND INSTRUCTIONS ON THE ADHESIVE LABEL.
• DO NOT PERMIT EXCESS ADHESIVE TO COLLECT ON THE INSIDE OF THE TUBING (AFTER THE JOINT IS SECURED)
• AFTER SECURING THE JOINT, USE A GLUE BRUSH TO WIPE AWAY EXCESS ADHESIVE ON THE OUTSIDE OF THE JOINT.
• GLUE AND TAPE ALL SYSTEM TUBE JOINTS FOR A PROPER AIR SEAL. DO NOT GLUE JOINTS WHERE TUBING MEETS EQUIPMENT. ALL EQUIPMENT MUST BE ATTACHED WITH A BOLTED COUPLING TO ENSURE IT IS REMOVABLE FOR SERVICE.
• ENSURE TUBING REMAINS FREE OF ALL OBSTRUCTIONS. CHECK TUBING OR DEBRIS BEFORE MAKING FINAL CONNECTIONS.
• USE METALLIZED TAPE TO HOLD JOINTS TOGETHER WHILE THE ADHESIVE CURES.
• WARNING: NEVER USE HEAT TO RELEASE ADHESIVES. HEATING ADHESIVES MAY EMIT TOXIC FUMES. ONLY USE ADHESIVE REMOVAL
METHODS APPROVED BY THE ADHESIVE MANUFACTURER.
STRAIGHT END
OF TUBE
BELL END
OF TUBE
SEE NOTES FOR JOINT
REQUIREMENTS
48"-50"
RADIUS
4" TUBING IS USED FOR AIR LINE
PIPING
6" 90° ELBOW6" 45° ELBOW
6" INLINE TEE
6" 90° BEND (58 1136 01)
(36.70 LBS)
4" STRAIGHT TUBE (27.40 LBS)
6" STRAIGHT TUBE (41.20 LBS)
6"
120" TYPICAL
4" 6"
13 1/2"
6"
6"
3/ 4"
6"
9"
5"
5"
6"
45.00°
/1
6"
/1 6"
M
AX
18 27/64"
69 15/16" MAX 6"
4" 90° BEND (58 1135 01)
24.48 LBS
(69 1/116" MAX 4")
(6
1/ 4"
M
AX
45° AIR LINE
ELBOW
7"
4" INLINE TEE
3/
8"
7 3/4"
ALL TUBING 16 GAUGE GALVANIZED STEEL
16 GAUGE GALVANIZED STEEL (POST FORMED WALL THICKNESS
OF .062 NOMINAL) AND MEETING ASTM A 653 COATING
DESIGNATION G90 OR G60. MATERIAL TO HAVE A ROCKWELL
HARDNESS OF B45 MINIMUM AFTER FORMING AND WELDING
6 3/4"
6"/4" INLINE TEE
12"
4"
6" 9"
12"8"
3/
8"
6"
4"
9"
7"
90° AIR LINE
ELBOW
/3 2"
3 2 1/3
2"
4" DRIVE SLEEVE
6" DRIVE SLEEVE
6"
5"
6"Ø PTUBE6"Ø PTUBE
4"Ø PTUBE4"Ø PTUBE
6X4 REDUCER
5"
4"Ø6"Ø
STRAIGHT HUB
4" & 6" BOLTED COUPLING
3X 5/8-16 HEX NUT
3X 5/8-16 BOLT 2.0 MIN LENGTH
GROUND STRIP TO BE PLACED
BETWEEN GASKET AND TUBE
WITH TAB FOLDED TO THE INSIDE.
6" OR 4"
3/
4"
6"
3/
4" F
O R
4"
CO
UP
LI
N
G
6"/4" INLINE PRV ASSEMBLY
6" OR 4"
FIELD BORE HOLES
MIN 6' ABOVE STATION NIPPLE
FIELD BORE PRV HOLES. PRV
FLAP AND CLAMPS
ORIENT FLAP UP
INSTALL BYPASS PIPE END
WITH LABEL UP
STANDARD 4" OR 6"
TUBING, FIELD CUT
BOLTED COUPLING CONNECTION TO
TRANSFER UNIT
FIELD BORE (2) 2 3/4" Ø
HOLES FOR 6" BYPASS PIPE
9" MIN. FROM HOLES TO
TRANSFER UNIT
STORAGE/BYPASS PIPE ASSEMBLY
65" MIN AS SHOWN
FIELD BORE (2) 1 7/8"Ø HOLES
FOR 4" BYPASS PIPE
9" MIN
BOLTED COUPLING CONNECTION
PRV 90
ACCEPTABLE
PRV LOCATION
WHEN PRV IS REQUIRED TO BE RELOCATED DUE TO
FIELD CONDITIONS, RELOCATE IN UPPER HALF OF BEND.
START OF RADIUS
ACCEPTABLE PRV LOCATION
PLAN VIEW
ELEVATION VIEW
VACUUM BYPASS VALVE
(IF APPLICABLE)
TO BLOWER
ZERO-LEVEL
TRANSFER UNIT
REDUCER (USED ON 6" SYSTEM)
VACUUM TEE
BOLTED COUPLING
NOTES:
A. STOPPING CHAMBER PIPING: 12' MIN, 15' PREFERRED
1. WHEN USING 4" SYSTEM, 15' REQUIRED BEFORE USING 4" AIRLINE FITTINGS
B. 6' BETWEEN VBV AND VACUUM TEE
C. 6' BETWEEN VACUUM TEE AND ZERO LEVEL TU
4" AIRLINE PIPING STOPPING CHAMBER "A"
4" AIRLINE PIPING
SYSTEM PIPING
6" AIRLINE 90
GLUED JOINT
"B"
"C"
ELEVATION VIEW
1/2" GAP AT JOINT
4" OR 6"Ø PNEUMATIC TUBE,
16 GAUGE GALVANIZED STEEL
36" MAX.
TRANSVERSE BRACING & LONGITUDINAL
BRACING (TYP) EA SIDE OF JOINT
4" OR 6"Ø SLIP JOINT
3/8"Ø ALL THREAD HANGER
ROD W/ STIFFENER
10'-0" MAX (TYP)
PNEUMATIC TUBE SUPPORT
±42"
BUILDING SEPARATION
BOLTED
COUPLING
PRV FLAP AND CLAMPS
ORIENT FLAP UP
STANDARD 4" OR 6"
TUBING, FIELD CUT
FIELD BORE (2) 2 3/4" Ø
HOLES FOR 6" PRV
- 7
/8
FIELD BORE (2) 1 7/8"Ø
HOLES FOR 4" PRV
- 3
/8
FIELD INSTALL FOR PRV 90,
INLINE PRV, OR
STORAGE/BYPASS PIPES
3/8" ALL THREAD HANGER ROD
AND HARDWARE
STEEL TEAR DROP HANGER4" OR 6" PNEUMATIC
TUBE
3/8" DROP-IN ANCHOR, TYPICAL
(SUBSTITUTE BEAM CLAMP WHERE
REQUIRED TO ANCHOR TO STEEL BEAMS)
3/8" THREADED ROD & HARDWARE,
TYPICAL
TUBE CLAMP,
TYPICAL
THREADED RODS TO
STRUCTURE ABOVE
TEARDROP HANGER
TUBE SUPPORTS FROM STRUCTURE ABOVE
13/16 OR 1-5/8" STRUT SUPPORT, AS
REQUIRED BY INSTALLATION
3/8"-16 NC DROP IN ANCHOR,
TYPICAL
3/8"-16 NC DROP IN ANCHOR,
TYPICAL
BENDS TO BE
SUPPORTED AT EACH END
SUPPORT ON RADIUS OF BEND IF
FIELD CONDITIONS DICTATE
NOTES:
• TOP TUBE TO BE SUPPORTED IN TYPICAL APPROVED FASHION
• DOUBLE HANGER SHOULD BE WITHIN 18" FROM TOP TUBE SUPPORT
• RODS BETWEEN TEARDROP HANGERS ARE TO BE PLUMB AND LEVEL
• ATTAIN APPROVAL PRIOR TO HANGING
• ONLY HANG FROM PNEUMATIC TUBING, NO OTHER TRADES
PHD BAND HANGER
A
"A"
8"
12"
4" TUBE
6" TUBE
PHD BAND HANGER
6" TUBE/
4" TUBE
10"
BOTH 4" OR
BOTH 6"
4" OR 6"
FLOOR PENETRATION PLAN VIEWFLOOR PENETRATION SECTION VIEW
FIRE STOP
PENETRATION
AS REQUIRED
CORE DRILLED OR
SLEEVED HOLE
4" OR 6" O.D. STEEL PNEUMATIC TUBE
FIRE STOP PENETRATION
AS REQUIRED
ROW CLAMP
4" PNEUMATIC TUBE - 5" OR 6" TYPICAL SLAB PENETRATION
6" PNEUMATIC TUBE - 7" OR 8" TYPICAL SLAB PENETRATION
FLOOR PENETRATION PLAN VIEWFLOOR PENETRATION SECTION VIEW
FIRE STOP
PENETRATION
AS REQUIRED
1-5/8 X 1-5/8" STRUT
4 HOLE 90 BRACKET
3/8" ANCHOR BOLTS
CORE DRILLED OR
SLEEVED HOLE
4" OR 6" O.D. STEEL
PNEUMATIC TUBE
1-5/8 X 1-5/8" STRUT
3/8" ANCHOR BOLTS
FIRE STOP PENETRATION
AS REQUIRED
CHANNEL CLAMP
4" PNEUMATIC TUBE - 5" OR 6" TYPICAL SLAB PENETRATION
6" PNEUMATIC TUBE - 7" OR 8" TYPICAL SLAB PENETRATION
4 HOLE 90 BRACKET
/1 6"
MECHANICAL SHAFT
PLAN VIEW
MECHANICAL SHAFT
SECTION VIEW
SCHEDULED
SHAFT OPENING
4" OR 6" O.D. STEEL
PNEUMATIC TUBE
1-5/8 X 1-5/8" STRUT
3/8" ANCHOR BOLTS
CHANNEL CLAMP 3/8" ANCHOR BOLTS
1-5/8 X 1-5/8" STRUT
UNISTRUT OR EQUAL ANGLE FITTING
SCHEDULED SHAFT OPENING
4" OR 6" O.D. STEEL PNEUMATIC TUBE
OPENING
SCHEDULED
NOTES:
1.AS SHOWN:
4" TUBE = 24" - ADDITIONAL 6" PER EACH ADDITIONAL TUBE
6" TUBE = 34" - ADDITIONAL 8" PER EACH ADDITIONAL TUBE
2.AS SHOWN:
4" TUBE = 6"
6" TUBE = 8"
3.MAY VARY DUE TO STRUCTURAL REQUIREMENTS. VERIFY.
"A" "B"
4" 6"
5"
4" TUBE
6" TUBE 8"
"C"
NOTE 1
NOTE 1
"D"
NOTE 2
NOTE 2
C
A B
B B
A
D
"C" & "D" REPRESENT OVERALL
SHAFT OPENING SIZE
1" WD X 1/8" THICK GALVANIZED STEEL 4" OR 6"
TUBE CLAMP
3/8" THREADED ROD
NOTE:
TUBING TO BE SUPPORTED AT A MINIMUM OF EVERY 10'.
1 17/32" MIN
3" MIN FLUTE
3/8"16 NUT W/FLAT WASHER
1" WD X 1/8" THICK GALVANIZED STEEL 4" OR 6" ROW
CLAMP
3/8" THREADED ROD
3/8"16 NUT W/FLAT WASHER
3/8" 16 X 1" LG BOLT WITH FLAT WASHER
S H
E E
T N
U M
B E
R
SCALE
Phone: (800) 396-9666 www.swisslog-healthcare.com
As instruments of service, all designs, ideas, and information shown on these drawings are and shall remain the property of Swisslog Healthcare. No part thereof shall be copied, disclosed to others, or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Swisslog Healthcare. Visual contact with these drawings shall constitute conclusive evidence of acceptance of these restrictions.
Not To Scale
S H
E E
T N
A M
E
ABCD
12/2/2019 10:19:23 AM
C
C ad
G ro up \L ib ra ry
R ev it\ D et ai ls \S w is sl og
D et ai ls
0x v
.r vt
PT-300
Tubing & Support Details
Beam Clamp
Adhesive Joint Connection Detail
Transmission Components
Bolted Coupling
Inline PRV
Storage/Bypass Pipe
PRV 90
System Piping
Expansion Joint Detail
Field Bore PRV
Typical Tube & Bend Supports
2 Band Hanger Support
Tube Supports at Floor Row Clamps
Tube Supports at Floor
Tube Supports at Shafts
1" = 1'-0"
Tube Supports Row Clamps
ORIENT STUDS WITH FLAT SIDE
AGAINST STATION HOUSING
FINISHED WALL AND FRAMING BY
OTHERS
TUBES SUPPORTED
AT FLOOR BY SWISSLOG
STATION HOUSING (TYPICAL), REFER TO
STATION DETAILS FOR DIMENSIONS
CORES MAY BE POSITIONED INSIDE STATION
ENCLOSURE. SEE PLANS FOR ADDITIONAL INFORMATION.
4" PNEUMATIC TUBE - 5" OR 6" TYPICAL SLAB PENETRATION
6" PNEUMATIC TUBE - 7" OR 8" TYPICAL SLAB PENETRATION
A
B
B
FROM HOUSING
10" CLEAR MIN TYP
MIN - MAY VARY DEPENDING ON
STRUCTURAL REQUIREMENTS
6" TUBE:
A=10" MIN
B=10" MIN
4" TUBE:
A=8" MIN
B=8" MIN
ADJUSTABLE LEG
ASSEMBLY
CARRIER
STORAGE RACKS
PRESSURE RELIEF VALVE
(PRV) BEND
8" MINIMUM CLEARANCE REQUIRED
AROUND PRV FLAP
AREA ABOVE STATIONS WITHIN STATION ENCLOSURE
SHALL BE CLEAR TO DECK/STRUCTURE ABOVE.
COORDINATE WITH SWISSLOG TO BE KEPT CLEAR OF
OBSTRUCTIONS TO TUBING
WALLS AND FRAMING BY
GENERAL CONTRACTOR OR
OWNER
STATION ANCHORED TO SLAB
INLINE PRESSURE RELIEVE VALVE (PRV)
ASSEMBLY: FOR STATIONS FED
VERTICALLY FROM THE FLOOR ABOVE.
G.C. TO NOTCH TRACK TO FIT
STATION LEGS
CORES MAY BE POSITIONED INSIDE STATION
ENCLOSURE. SEE PLANS FOR ADDITIONAL INFORMATION.
BOLTED COUPLING
TRIM
FRAME
RECEIVE BIN
DISPATCHER
NIPPLE
SIDE
FRONT
CONTROL
PANEL
STATION FURR-IN BY
OTHERS. STUDS TO BE
ORIENTED WITH FLAT SIDE
AGAINST STATION HOUSING
STATION HOUSING (TYPICAL), REFER TO
EQUIPMENT DETAILS FOR DIMENSIONS
32 3/8"
D
8"
R
EF
ER
EN
C E
C
EI
LI
N
G
/4
/8
/2
/8
" R
.O
F ROUGH OPENING
E (MIN CLEAR)
1/2" MIN FROM TRIM PLATE TO
WALL CORNER, TYP
TOP
/8
/2
/8 " R
O
TOP
POWER CONDUIT ENTRY
COMMUNICATION
CABLE/CONDUIT
ENTRY
A
B
/8
C
1/
BOTTOM
3/
4"9"
POWER CONDUIT TO
ELECTRICAL PANEL
SIZE
4" 6"
A 26 1/8" 32 1/8"
B 4 7/8" 5 7/8"
C 28 3/4" 34 3/4"
D 11' 10 1/8" 11' 8 1/8"
/8
A = STATION HOUSING WIDTH
B = STATION HOUSING EDGE TO CENTER OF NIPPLE
C = TRIM RING WIDTH
D = FLOOR TO TOP OF PRV BEND *NOTE 1
E = CLEAR STATION ENCLOSURE WIDTH
F = ENCLOSURE ROUGH OPENING WIDTH
NOTE 1: VARIES PER FIELD CONDITIONS/CEILING HEIGHT
X'-X" MIN, X'-X" PREFERRED
E 28" 36"
F 26 1/4" 32 1/2"
DECK/STRUCTURE ABOVE
PRESSURE RELIEF VALVE (PRV):
PRV TO BE CLEAR OF OBSTRUCTIONS AND
ACCESSIBLE. WHEN STATION ENCLOSURE WALLS
ARE TO DECK AN ACCESS PANEL IS REQUIRED TO
ALLOW ACCESS TO THE PRV
6' M
IN
IF MOVED TO FLOOR ABOVE,
ACCESS PANEL REQUIRED, BY
OTHERS
STATION FURR-IN BY OTHERS. STUDS TO BE
ORIENTED WITH FLAT SIDE AGAINST
STATION HOUSING
STATION HOUSING
(TYPICAL), REFER TO
EQUIPMENT DETAILS FOR
DIMENSIONS
FLOOR
STATION ANCHORED TO SLAB
WALLS AND FRAMING BY OTHERS
PRESSURE RELIEF VALVE
(PRV) BEND
8" MINIMUM CLEARANCE
REQUIRED AROUND PRV
FLAP
AREA ABOVE STATIONS SHALL BE COORDINATED WITH SWISSLOG TO BE
KEPT CLEAR OF OBSTRUCTIONS TO TUBING
CORES/SLEEVES MAY BE POSITIONED INSIDE STATION
ENCLOSURE. SEE PLANS FOR ADDITIONAL INFORMATION.
ADJUSTABLE LEG
ASSEMBLY
INLINE PRESSURE RELIEVE VALVE
(PRV) ASSEMBLY: FOR STATIONS FED
VERTICALLY FROM THE FLOOR ABOVE.
IF REQUIRED TO MOVE TO FLOOR
ABOVE, ACCESS PANEL REQUIRED
G.C. TO NOTCH TRACK TO FIT
STATION LEGS
BOLTED
COUPLING
(TYPICAL)
BOLTED COUPLING
/8 " R
.O
36" MIN CLEAR
/8
30 1/2"
8"
R
EF
ER
EN
C E
C
EI
LI
N
G14
/6
4"
34 23/32"
RIGHT SIDE FRONT
32 1/2" R.O.
POWER
CONDUIT
ENTRY
COMMUNICATION
CABLE / CONDUIT
ENTRY
32 17/64"
15 31/32" 8 5/32"
9 11/32"
34 21/32"
TOP
M
IN
2" MIN FROM TRIM RING TO WALL CORNER, TYP
TOP
2" MIN
TRIM RING WIDTH
2" MIN
STATION HOUSING
STATION FURR-IN BY OTHERS. STUDS TO BE
ORIENTED WITH FLAT SIDE AGAINST
STATION HOUSING
STATION HOUSING
(TYPICAL), REFER TO
EQUIPMENT DETAILS FOR
DIMENSIONS
WALLS AND FRAMING BY OTHERS
12 3/8"
" TOP
UNIT
CARRIER
STORAGE
HOUSINGS
5" BETWEEN
HOUSING
STATION
HOUSINGS
5" BETWEEN
RESET/SILENCE BUTTON
ARRIVAL AMBER
SIGNAL LIGHT
4"
2 1/8" 4 1/2"
1/
2"
RPI - Remote Personal Indicator CAI - Carrier Arrival Indicator
S H
E E
T N
U M
B E
R
SCALE
Phone: (800) 396-9666 www.swisslog-healthcare.com
As instruments of service, all designs, ideas, and information shown on these drawings are and shall remain the property of Swisslog Healthcare. No part thereof shall be copied, disclosed to others, or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Swisslog Healthcare. Visual contact with these drawings shall constitute conclusive evidence of acceptance of these restrictions.
Not To Scale
S H
E E
T N
A M
E
ABCD
12/2/2019 10:19:35 AM
C
C ad
G ro up \L ib ra ry
R ev it\ D et ai ls \S w is sl og
D et ai ls
0x v
.r vt
PT-301
Station Details
Station Furring Options
Recessed Station
Ultra Station
Trim Ring Inside Corner Detail
Stations/Storage Unit Detail
RPI/CAI
STATION SPECIFICATIONS
Power provided to the station by others.
POWER REQUIREMENTS
110 VAC, 1 Ph, 3A, dedicated unswitched circuit, terminated inside the station-supplied duplex outlet.
Ultra Station: (2) station-supplied duplex outlets. (2) Data drops Swisslog recommends that each Ultra Station Port be placed on separate circuits.
CONTROL REQUIREMENTS
Ethernet Standard Protocol. Data drop required landed in each station housing, by others.
ENVIRONMENTAL REQUIREMENTS
Operating Temperature: 0° to 100° F Storage Temperature: -20° to 180° F Relative Humidity: 0% to 90%
Ultra Stations may have two (2) 6" nipples, two (2) 4" nipples, or one each of 6" and 4" nipples.
Weights:
Recessed/Nexus Station: 6" 240 lbs / 4" 200 lbs Nexus Station: 6" 500 lbs Ultra Station: 375 lbs Countertop Station: 150 lbs transmitted to countertop Wall Mount: 150 lbs transmitted to floor through vertical supports
Station Enclosure Framing:
Wall framing and GWB around station enclosure to stop above ceiling to allow access to Pressure Relief Valve (PRV). If wall(s) are required to go to deck, stop GWB above ceiling. If GWB also needs to go to deck, access panel required to access PRV. Access panel provided and installed by others
RECEIVE BASKET, SUPPLIED WITH MULTIPLE
RECEIVE OPTION
WALLS BY OTHERS
WALL MOUNT SUPPORTS ANCHORED
TO SLAB. (2) TYPICAL
DISPATCHER
RECEIVER
BOLTED COUPLING
28"
/8
7/
8"
15"
8"
R
EF
ER
EN
C E
C
EI
LI
N
G
/1
6"
Station - Wall Mount
EXISTING STATION, SHOWN FOR REFRENCE ONLY
RECEIVE BASKET, SUPPLIED WITH
MULTIPLE RECEIVE OPTION
MILLWORK/COUNTERTOP,
SUPPLIED BY OTHERS
CONTROL PANEL
DISPATCHER
SINGLE RECEIVER
(MULTIPLE RECEIVE OPTIONAL)
MULTIPLE RECEIVE OPTION
REQUIRES HOLE IN THE
COUNTER PROVIDED BY OTHERS
BOLTED COUPLING
28"
/8
7/
8"
15"
28"
C O
U N
TE
R
R
EF
ER
EN
C E
5/ 8" 14 3/8"
Station - Countertop
INSTALL A STRUT BRACE AT BETWEEN 30-60° (45°
PREFERRED) ANGLE TO THE AXIS OF THE
TRANSFER UNIT, TYP ONE EACH AXIS
3/8"-13NC THREADED ROD, ANCHORS,
AND HARDWARE AT (4) PLACES TYPICAL
3/8" DROP-IN ANCHOR, TYPICAL (SUBSTITUTE BEAM CLAMP
WHERE REQUIRED TO ANCHOR TO STEEL BEAMS - SEE DETAILS)
4 PORT SHOWN, 2 PORT AND 6 PORT SIMILAR
TRANSVERSE BRACE
LONGITUDINAL BRACE
CONTROL REQUIREMENTS:
4-conductor PVC insulated cable, #22 AWG shielded twisted pair with ground wire.
5VDC maximum open circuit voltage, 200 mA maximum short circuit current
1X4 Transfer Unit shown. 1x2 and 1x6 Units are similar.
COMMUNICATION CABLE
ENTRANCE
BACK VIEW
POWER CONDUIT ENTRANCE
BOTTOM
TOP
POWER ENTRY
COMMUNICATION
CABLE ENTRY
ACCESS PANEL MAY FACE
DOWN OR TO THE SIDE
SERVICE
ACCESS
B
F K
SERVICE
ACCESS
ACCESS PANEL:
TU MAY BE ROTATED VERTICAL.
SERVICE ACCESS AVAILABLE TO ONE
SIDE ONLY
FRONT BACK
SIDE
24"
ACCESS
TOP
SIZE
6" 4"
A 47" 43"
B 42" 38"
C 23 1/2" 18 1/2"
D 10 1/2"
8"
E 40 1/4" 36 1/4"
F 7 5/8" 5 5/8"
G 21" 16"
H 8"
5 1/2"
J 4 1/2" 3 3/4"
K 15" 12"
H G
H
A
E
D
C
J H
FR
O
N T
BA
C
K
BOTTOM
1/
2" 8"
27/32" 41 5/32"
ACCESS PANEL:
MAY FACE DOWN
OR TO THE SIDE
POWER ENTRY
COMMUNICATION
CABLE ENTRY
24" ACCESS
EITHER SIDE OR BOTTOM
SIDE ACCESS PREFERRED
TOP
D
E
E
B
A
G F
G
0 1
2 3
SERVICE ACCESS
ACCESS PANEL:
TU ROTATED TO ALLOW FOR BOTTOM ACCESS. ROTATE
SENSOR. PREFERRED TO HAVE POWER ENTRY SIDE
DOWN.
/2
SERVICE ACCESS
24" MIN
24" MIN
POWER ENTRY
COMMUNICATION CABLE ENTRY
SIZE
6"
6" Mini 4"
A 52 7/8"
44" 50 1/2"
B 47 1/4" 34 3/4" 44 1/2"
C 21 1/2" 18 7/8"
18"
D 21 1/2" 18 7/8"
18"
E 8" 8"
6 5/8"
F 17"
16 1/4" 13 1/2"
C
4" 1X4
6" 1X4
POWER ENTRY
COMMUNICATION
CABLE ENTRY
6" 1X4 Mini
SERVICE ACCESS
REQUIRED FOR MOTOR
BOLT ACCESS ON MINI
6"
J H J
H
G 2 1/4" 1 1/8" 2 1/4"
JJ
H 45 7/8" 33 7/8" 43 1/8"
J 11/16" 7/16" 11/16"
G R
N
BL
K
W
HTRING TERMINAL
3/16" QUICK CONNECT
WITH INSULATORS
GROUNDING STUD
CONDUIT CLAMP
CONDUIT FITTING
TYPE SVT OR SV CORD
RUBBER GROMMET SEAL
1/2" CONDUIT TO
TRANSFER UNIT
VACUUM BYPASS J-BOX
12"
12"
4" VACUUM BY PASS VALVE
6" VACUUM BY PASS VALVE
ELECTRICAL CONNECTION,
POWERED FROM TU
16 31/64"
6"
/1 6"
4"
3/
8"
13 1/2"
4"
12"
/1 6"
VACUUM BYPASS VALVE, SEE
DETAILS
CABLE TIES
FLEX CONDUIT (BY OTHERS)
TO 115 VAC ELECTRICAL POWER SOURCE
(BY OTHERS)
TRANSFER UNIT
ENCLOSURE
MOTOR CONTROL ASSEMBLY
POWER OUTLET FOR VACUUM
BYPASS VALVE
PLUG
115VAC POWER TERMINATIONS INSIDE J-BOX
SEE DETAILS
VACUUM BYPASS VALVE WIRING
1/
8"
2 13/64"
BAND CLAMP
DRILL (2) 2"Ø HOLES
INSTALL ON ALL OPEN TU PORTS
INSTALL WITH HOLES ORIENTED VERTICALLY
LOCK NUT
GROUNDING STUD
B
LK
W H
T
GRN
LOCK WASHER
RING TERMINAL
HEX NUT
CABLE CLAMP
VACUUM BYPASS GROUNDING STUD12
/4
8"
TRAFFIC ENHANCEMENT UNIT (TEU)
1. POWER AND DATA SUPPLIED TO CONTROL ENCLOSURE BY OTHERS
2. CONTROL ENCLOSURE MOUNTED BY SWISSLOG
3. DATA FROM CONTROL ENCLOSURE TO TEU BY SWISSLOG
4. SEE PRODUCT DATA SUBMITTAL FOR LOCATION OF DATA AND
POWER INTO ENCLOSURE
12 1/4"
TEU CONTROL ENCLOSURE
FRONT VIEW LEFT VIEW RIGHT VIEW
TEU SENSOR
9"
4 1/2" 4 1/2"
BOLTED COUPLING
EACH SIDE OF TEU
S H
E E
T N
U M
B E
R
SCALE
Phone: (800) 396-9666 www.swisslog-healthcare.com
As instruments of service, all designs, ideas, and information shown on these drawings are and shall remain the property of Swisslog Healthcare. No part thereof shall be copied, disclosed to others, or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Swisslog Healthcare. Visual contact with these drawings shall constitute conclusive evidence of acceptance of these restrictions.
Not To Scale
S H
E E
T N
A M
E
ABCD
12/2/2019 10:19:48 AM
C
C ad
G ro up \L ib ra ry
R ev it\ D et ai ls \S w is sl og
D et ai ls
0x v
.r vt
PT-302
Transfer Unit Details
Transfer Unit Support - (Sway Bracing)
Transfer Unit Wiring
Transfer Unit 1x2
Transfer Unit 1x4
Vacuum Bypass Valve
6" TU Port Cap
TEU - Traffic Enhancement Unit
TRANSFER UNIT SPECIFICATIONS
DRIVE MECHANISM
Electromechanical
POWER REQUIREMENTS
110 VAC, 1 Ph, 3A, dedicated unswitched circuit, terminated inside the equipment-supplied duplex outlet.
CONTROL REQUIREMENTS
Ethernet Standard Protocol. Data drop required landed in each TU, by others.
ENVIRONMENTAL REQUIREMENTS
Operating Temperature: 0° to 120° F Storage Temperature: -20° to 180° F Relative Humidity: 0% to 90% Maximum System Vacuum/Pressure: 4 psig Heat output: Approximately 130 BTU/hr
Weights:
1x2 Transfer Unit: 4" 125 lbs / 6" 165 lbs.
1x4 Transfer Unit: 4" 145 lbs / 6" 185 lbs.
1x4 Mini Transfer Unit: 95 lbs. (6" Only) 1x6 Transfer Unit: 4" 205 lbs. / 6" 250 lbs.
31"
/1 6"
28"
PLAN ELEVATION
30"
28"
PRESSURE SIDE VACUUM SIDE
A-A SECTION A-A
THROUGH BLOWER CONTROL CABINET
CONTROL
LOGIC AREA
DOOR SWINGS OPEN TO THE
LEFT
090-2675-01 BOARD
TB3
086-3493- ASSEMBLY
TB4
REV
12 VAC 5 VDC
GRN
SHIELD
BLK
WHT
TB1
RED
IN
TB2
OUT
A-A
INTERNAL VIBRATION
ISOLATION
FLEXIBLE HOSE
CONNECTION
*NOTE: SOME JURISDICTIONS REQUIRE 42" CLEAR.
CONSULT LOCAL AUTHORITIES.
SYSTEM AIR PIPING
BLOWER STAND
BY SWISSLOG
P
A
V
P R
E S
S U
R E
84"
2" 28" 2"
TO
S
TA
R
TE
R
" C
LE
AR
C
LE
AR
/6
4"
3/
NOTE: SCREEN BOX AND AIR LINES VERTICALLY SUPPORTED BY A FIELD FABRICATED STRUT SUPPORT ASSEMBLY AS DICTATED BY
INSTALLATION CONDITIONS.
12" 32" 40"
A T
M O
S P
H E
R E
V A
C U
U M
SCREENBOX
SCREENBOX
GLASS SIDE
SCREENBOX
ATMOSPHERE SCREENBOX
MUFFLERS ON PRESSURE
AND VACUUM
1/
4"
1/ 4"
42 3/8" 18" 7 1/4"
INSTALL AIRLINE PIPING
SUPPORT PER FIELD
CONDITIONS
LOCATION OF VFD
WHEN APPLICABLE
208-230
22.6 11.3
3 PHASE
VOLTAGE
(VAC)
FULL LOAD
CURRENT
(AMPS)
HP
6" BLOWER POWER
208-230
12.0 5.5 4.5
3 PHASE
VOLTAGE
(VAC)
FULL LOAD
CURRENT
(AMPS)
HP
4" BLOWER POWER
4.5 4.5 4.4
4" System:
Weight: 395 lbs.
With VFD: 405 lbs.
Heat Output: Approx. 9,000 BTU/hr Maximum Operating RPM 3,500 or 4,080 with VFD
6" System:
Weight: 285 lbs.
With VFD: 295 lbs.
Heat Output: Approx. 8,000 BTU/hr Maximum Operating RPM 3,520 or 4,080 with VFD
575 10.7 10.1
3 PHASE
VOLTAGE
(VAC)
FULL LOAD
CURRENT
(AMPS)
HP
6" BLOWER POWER 575 VAC 6" System:
Weight: 395 lbs.
With VFD: 405 lbs.
Heat Output: Approx. 8,000 BTU/hr Maximum Operating RPM 3,540 or 4,080 with VFD
/4
4" AIRLINE
4" AIRLINE
MUFFLER
SCREEN BOX
6"5 1/8"6"
FRONT SIDE
4" AIRLINE
4" AIRLINE
SCREEN BOX5"
6 7/8"
4" AIRLINE
7" 7"
5 1/4"
S H
E E
T N
U M
B E
R
SCALE
Phone: (800) 396-9666 www.swisslog-healthcare.com
As instruments of service, all designs, ideas, and information shown on these drawings are and shall remain the property of Swisslog Healthcare. No part thereof shall be copied, disclosed to others, or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Swisslog Healthcare. Visual contact with these drawings shall constitute conclusive evidence of acceptance of these restrictions.
Not To Scale
S H
E E
T N
A M
E
ABCD
12/2/2019 10:19:57 AM
C
C ad
G ro up \L ib ra ry
R ev it\ D et ai ls \S w is sl og
D et ai ls
0x v
.r vt
PT-303
Blower Details
Blower Stand
Blower Control Cabinet
Blower
Blower Muffler
Screen Box
Atmosphere Screen Box
BLOWER SPECIFICATIONS
POWER REQUIREMENTS
Shifter Valve Motor: 110 VAC, 1 Phase, 5.4 A, dedicated unswitched circuit, terminated inside the equipment-supplied duplex outlet.
Blower Motor: 200-230, 460, or 575 VAC, 3 Phase Electrical Disconnect Required, By Others
Size all circuit protection in accordance with local, state, and national electrical codes
CONTROL REQUIREMENTS
Ethernet Standard Protocol. Data drop required landed in each blower control box, by others.
ENVIRONMENTAL REQUIREMENTS
Operating Temperature: 0° to 120° F (-17.8° - 49° C) Storage Temperature: -20° to 180° F (-29° - 65° C) Relative Humidity: 0% to 90% Maximum Operating RPM: 3,500 Maximum System Vacuum/Pressure at 5000 ft / 1.5 km:
3.5 psig Maximum Output @ zero pressure and 500 ft: 330
SCFM
The general contractor or the owner shall supply adequate supply and relief air to blower locations to ensure that all environmental and airflow requirements are met.
Sound Levels:
Without Sound Package: 82 dbA With Sound Package: 72 dbA
Sound Package and VFD available as factory-installed option only
MAX. VACUUM/PRESSURE: (at 5000 ft)
3.5 psig
MAX. OUTPUT: (at zero pressure and 500 ft)
165 SCFM for 4-inch 330 SCFM for 6-inch
659-24-202 Pneumatic Tubes
Electrical and Data Locations
07/05/2022
Equip # Elect. Room Elect. Panel IT Closet/Rack
ST 114 1204 2C1A1A TU:
ST 115 1204 2C1A1A ST:
ST 214 1204 2C1A1A TEU:
TU 014 1204 2C1A1A
TU 027 1204 2C1A1A
ST 123 2176 2C1A1B
TU 011 2176 2C1A1B
TU 012 2176 2C1A1B
TU 013 2159 2C1A2B
ST 133 3177 2C1A1C
ST 134 3153 2C1A2C
TU 017 3153 2C1A2C
TU 016 3177 2C1A1C
ST 143 4167 2C1A1D
ST 144 4015 2EM7A
ST 153 5126 2C1A1E
ST 154 5104 2C1A2E
Equip # Elect. Room Elect. Panel IT Closet/Rack
TU 031 (TU 018) B4, G032 4SP A171
ST 310 (ST 116) A146 1C1 A171
ST 320 (ST 125) A246 2C1 A271
ST 330 (ST 135) A346 3C1
TU 302 (TU 019) A346 3C1
Equip # Elect. Room Elect. Panel IT Closet/Rack
Relocated/New TU 10 A-222 2CALA A-201
Blower 003 A-222 2CALA A-201
TU 032 (TU011) A-222 2CALA A-201
Equip # Elect. Room Elect. Panel IT Closet/Rack
TU 034 (TU 191) BA101 GLS1A BC118
ST 321 (ST 122) 2A101 2CR1A 2C114
Equip # Elect. Room Elect. Panel IT Closet/Rack
ST 211 1B104 ISLA 1B103
ST 212 1C136 EE1LW 1C135
ST 213 1D135 EE1CL 1D136
Blower 002 2B104 2SH (277/480V)
TU 020 2B104 EE2LA
ST 221
TU 021
ST 222
TU 022
ST 223
TU 023
Equip # Elect. Room Elect. Panel IT Closet/Rack
ST 201 SP121-43 EM1L 109
RPI 202
Location Elect. Room Elect. Panel IT Closet/Rack
TEU 26 B5 1012 CORR. SPswitchroom-5 EEPC 1017
TEU 25 B5 to B6 Tunnel "E" G007 5AA 1017
TEU 24 B6 to B42 Bridge B42, SP2A100 EEPA BC148
TEU 033 (TEU 190) B21 Tunnel "I" BC119 EEPA BC118
Building 20
FEED WITH RS-422 CABLE FROM STATION #201
Building 2
Legend
1190A
Transfer Unit
Recessed Station
Traffic Enhancement Unit
RR-Revised 7/12/2022
2176 or 2026
JS-Revised 7/14/2022
JS-Revised 9/19/22
JS-Revised 10/06/22
A371
Building 8
Building 21
Building 42
2A129
2B104 EE2LA 2B130
Building 43
Additional Locations for TEUs
2C136 EE2WI 2C135
2D135 EE2CL 2D136