Drawings-Code Plans 31 pages.pdf

PDF 16 MB Posted

Attached to
Z2DA--Correct Fire & Life Safety Deficiencies PN# 589A4-19-104
Solicitation number
36C25520R0074-3
Issued by

About this file

This solicitation is for corrective fire and life safety deficiency projects at the Harry S. Truman Memorial Veterans' Hospital located in Columbia, Missouri. The solicitation number is 36C25520R0074-3 and was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15. Key project details include renovating and upgrading fire alarm, sprinkler, and egress systems; replacing fire barriers and smoke partitions; and correcting other deficiencies to bring the facility into compliance with NFPA 101: Life Safety Code and other standards. The solicitation includes 31 pages of construction drawings detailing the specific corrective work. The response due date is not provided, and the period of performance or award date is also unspecified. Pricing terms and any set-asides or incumbent contractors are not mentioned.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PENTHOUSE

1967NORMALLY

UNOCCUPIED BUILDING

SERVICE EQUIPMENT

SUPPORT AREA

BASEMENT

19672008

(CH. 39)

EXISTG. BUSINESS

(CH. 39)

EXISTG. BUSINESS

(CH. 42)

EXISTG. STORAGE

(CH. 39)

EXISTG. BUSINESS

1ST FLOOR

19672008

(CH. 21)

EXISTG. AMB, CARE

(CH. 19)

EXISTG. HEALTH

CARE

(CH. 19)

EXISTG. HEALTH CARE

(CH. 19)

EXISTG. HEALTH CARE

(CH 21)

EXISTG.

AMB. CARE

(CH 19)

EXISTG.

HEALTH

CARE

2ND FLOOR

(CH. 19)

EXISTG. HEALTH

CARE

(CH. 21)

EXISTG. AMB. CARE

(CH. 19) EXISTG.

HEALTH CARE

(CH 21)

EXISTG.

AMBULATORY

CARE

3RD FLOOR

(CH. 19)

EXISTG. HEALTH CARE

(CH. 21)

EXISTG. AMBULATORY

CARE

(CH. 19)

EXISTG.

HEALTHCARE

INTERSTITIAL

SPACE

4TH - 6TH FLOORS

4TH FLOOR - (CH. 19)

EXISTG. HEALTH CARE

5TH & 6TH FLOOR -

(CH. 39)

EXISTG. BUSINESS

CODE NOTES

NOTE: THESE DWGS DO NOT INCLUDE IBC BUILDING CODE

INFORMATION

1. DRAWING PURPOSE: NFPA CODE COMPLIANCE

2. FACILITY REVIEWED FOR COMPLIANCE WITH THE FOLLOWING

CODES:

2018 NFPA 101 LIFE SAFETY CODE

CHAPTER 19 - EXISTING HEALTHCARE OCCUPANCY

CHAPTER 21 - EXISTING AMBUL HEALTHCARE OCCUPANCY

CHAPTER 39 - EXISTING BUSINESS OCCUPANCIES

3. OWNER:

HARRY S TRUMAN MEMORIAL HOSPITAL

800 HOSPITAL DR

COLUMBIA, MO 65201

PH (573) 814-6000

4. DATE DEVELOPED: 4/5/16

6. ARCHITECTS SEAL: SEE STAMP IN TITLEBLOCK

7. FIRE SERVICE: CITY OF COLUMBIA FIRE DEPARTMENT

8. INSPECTION: JCHO; CITY OF COLUMBIA

9. OCCUPANCY GROUP TYPE:

5. ARCHITECT:

M+HFG

142 N MOSELY ST STE 300

WICHITA, KS 67212

PH (316) 262-2500

OCCUPANCY 1

OCCUPANCY 2

OCCUPANCY 3

OCCUPANCY 4

- HEALTHCARE

- AMBULATORY HEALTH CARE

- BUSINESS

- STORAGE

10. CONSTRUCTION TYPE:

OCCUPANCY 1, 2 & 3 - NFPA TYPE II (222)

OCCUPANCY 4 - NFPA TYPE II (000)

11a. BUILDING 1 - OCCUPANCY 1 - FLOOR AREA

ACTUAL:

OCCUPANCY I - HEALTH

CARE

FIRST FLOOR

SECOND FLOOR

THIRD FLOOR

FOURTH FLOOR

FIFTH FLOOR

SIXTH FLOOR

LOWER PENTHOUSE

UPPER PENTHOUSE

???,??? SF

76,142 SF

75,957 SF

22,902 SF

4,322 SF

22,902 SF

22,902 SF

4,322 SF

TOTAL: 311,200 SF

OCCUPANCY 3 - BUSINESS

BASEMENT

GRAND TOTAL: 673,743 SF

NOTE: GROSS FLOOR AREA USED TO CALCULATE

SF PER NFPA 3.3.22.2.1 (INSIDE FACE OF

EXTERIOR WALLS WITH NO DEDUCTS FOR

HALLWAYS, STAIRS OR THICKNESS OF INTERIOR

WALLS)

11c. HEIGHT & AREA LIMITATIONS:

ALLOWABLE AREA: UNLIMITED

HEALTH CARE OCCUPANCY

ALLOWABLE HEIGHT /

STORIES

4 OR MORE

ACTUAL HEIGHT / STORIES 7 OCCUPIABLE

STORIES

BUSINESS OCCUPANCY

ALLOWABLE HEIGHT /

STORIES

N/R

11d. MINIMUM CONSTRUCTION REQUIREMENTS (A.8.2.1.2):

CONSTRUCTION

HEALTH CARE OCCUPANCY

BEARING WALLS:

A. EXTERIOR

B. INTERIOR

C. INT/EXT (ROOF ONLY)

OCCUPANCY 2 - AMBULATORY HEALTH CARE

FIRST FLOOR 42,158 SF

TOTAL: 110,844 SF

TYPE II

(222)

2 HR

2 HR

1 HR

NON-BEARING WALLS:

A. EXTERIOR

B. INTERIOR

0 HR

NON-

COMBUSTIBLE

COLUMNS:

A. SUPPORT FLOORS

B. SUPPORT ROOF ONLY

2 HR

1 HR

BEAMS/GIRDERS/TRUSSES:

A. EXTERIOR:

B. INTERIOR:

2 HR

1 HR

FLOOR CONSTRUCTION: 2 HR

ROOF CONSTRUCTION: 1 HR

NOTE: ENTIRE FACILITY IS FULLY SPRINKLED

12. ACTIVE FIRE SAFETY FEATURES:

(A) AUTOMATIC SUPPRESSION SYSTEMS:

- SPRINKLER SYSTEM (FULLY SPRINKLED)

- EXHAUST HOOD IN KITCHEN - U.L. 300 COMPLIANT

- AUTOMATIC AIR-HANDLING SHUT-DOWN

(B) FIRE ALARM SYSTEM - SIMPLEX, ADDRESSABLE, AUTO DIAL-UP

(C) GENERATOR POWERED EMERGENCY LIGHTING, GENERATOR

POWERED EXIT LIGHTING.

(D) SMOKE DETECTORS AT ALL CORRIDORS, ALL SMOKE DOORS AND

MISC AREAS AS REQ'D (ALSO IN SOME DUCTS)

(E) PORTABLE EXTINGUISHERS

13. WATER SUPPLY: CITY OF COLUMBIA

VA EQUIVALENCY:

VA ALLOWED 100'-0" DEAD END CORRIDORS IN B OCCUPANCY

AREAS

OCCUPANCY 4 - STORAGE

BUILDING 1 - OCCUPANCY 2, 3 & 4 - FLOOR AREA

ACTUAL:

11b. BUILDING 2 FLOOR AREA ACTUAL:

OCCUPANCY 4 - STORAGE

BASEMENT 14,193 SF

BASEMENT 158,877 SF

SUB-BASEMENT 32,825 SF

2ND FLOOR 41,821 SF

TYPE II

(000)

0 HR

0 HR

0 HR

0 HR

NON-

COMBUSTIBLE

0 HR

0 HR

0 HR

0 HR

0 HR

0 HR

TOTAL: 204,681 SF

3RD FLOOR 26,865 SF

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

WALL

RATING

NEW

PARTITION KEY NFPA 101-2018

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER

2 HR

90 MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

2 HR

90 MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER

2 HR

90 MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)

(1/2 HR = EXIST. ENCL. IN EXIST BLD'G)

1 HR

2 HR

60 MIN

90 MIN

HAZ./INCIDENTAL USE

FIRE BARRIER

1 HR 45 MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS

(SPRINKLERED)

NR-

RESIST

SMK

NR

SELF OR AUTO

CLOSING

SUBDIVIDING SPACES

SMOKE BARRIER (I-2 OCCUPANCY)

20 MIN

1/2

HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

NR

*NR

SELF OR AUTO

CLOSING

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

NR

1 HR

VERT. OPG. (SHAFT)

FIRE BARRIER 60 MIN

1 HR

2 HR

60 MIN

90 MINEXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

6.1.14.4.1 19.1.3.5.1

7.2.4.1.3 (1) 19.1.3.8 19.2.2.5 7.1.3.2.1

19.3.1.1-8 8.6

8.7.1 19.3.2.1

8.5

8.4.2 19.2.5.7.1.4

8.4.2 19.3.6.2

21.3.6 35.3.6

19.3.1

7.2.6

8.2.1.3

8.6

19.2.2.7

8.6

19.3.2.1.2

19.3.7.3

7.2.1.4.1 7.2.4.3.7 8.3.4 19.2.2.5, 1-4

8.3.3.2.2 TBL

19.2.2.2

7.1.3.2 (9)

8.3.3.2.2 TBL

19.3.2.1.3

8.3.3.2.2 TBL

8.5.4 19.3.7.8

8.3.3.2.2 TBL

19.2.2.2.

8.3.3.2.2 TBL

8.3.3.2.2 TBL

8.3.3.2.2. TBL

8.7.1.3 8.4.3 19.3.2.1.3

19.3.6.3.2 8.4.3

19.3.6.3 8.4.3

N/A

FIRE

90 MIN

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR

ONLY

N/A

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLOWED

8.3.4.8 9.2.1

8.3.4.8 9.2.1

8.3.4.8 9.2.1 7.2.4.3.5

N/A

8.5.5.3 19.3.7.3(2)

8.6.4.5

N/A

N/A

8.4.4

8.4.4 8.4.6.2

8.4.4.1 8.4.6.2 19.3.6.4.2

N/A

SYMBOLS

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

OCC. LOAD

FACTOR

FIRE ALARM CONTROL PANEL

FIRE SYSTEM ANNUNCIATOR ALARM

ANNUNCIATOR PANEL

FACP

FSA

FAA

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

ACTUAL EXIT

WIDTH

NO. OF OCC./

NO. OF EXITS

1:50

10/1

2"

34"

FEC

FP

PROPERTY LINE

STARTING

LOCATION

TRAVEL DISTANCE

TRAVEL PATH

FE

FIRE EXTINGUISHER CABINET

FIRE PULL STATION

FIRE EXTINGUISHER

NOTES

[A] DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS OF

SMOKE BARRIERS WHERE HVAC SYSTEMS ARE FULLY DUCTED

(19.3.7.3x2)

[B] AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL

HAVE DAMPERS (NFPA 8.2.4.4.3)

[C] SMOKE DAMPERS ARE NOT REQUIRED WHERE OPENINGS IN

DUCT ARE LIMITED TO A SINGLE SMOKE COMPARTMENT &

DUCTS ARE MADE OF STEEL

[D] TRANSFER GRILLES REGARDLESS OF WHETHER THEY ARE

PROTECTED

ARE NOT ALLOWED IN THESE DOORS OR WALLS (NFPA 19.3.6.4)

TD = XX

VICINITY MAP

NO SCALE

PROJECT LOCATION

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

G001

CODE PLANS - TITLE SHEET

CORRECT FIRE & LIFE

SAFETY DEFICIENCIES -

LIFE SAFETY PLANS

800 HOSPITAL DRIVE COLUMBIA, MO 65201

01-31-2020

589A4-19-104

CORRECT FIRE & LIFE SAFETY DEFICIENCIES -

LIFE SAFETY PLANS

HARRY S. TRUMAN MEMORIAL VETERANS' HOSPITAL

DEPT OF VETERANS AFFAIRS

800 HOSPITAL DRIVE COLUMBIA, MO 65201

100% CONSTRUCTION DOCUMENTS

100% CONSTRUCTION DOCUMENTS

SHEET INDEX

Sheet Number Sheet Name

G001 CODE PLANS - TITLE SHEET

LS000 CODE PLAN - SITE

LS000.5 CODE PLAN - SUB BASEMENT OVERALL

LS001 CODE PLAN - BASEMENT OVERALL

LS001.1 CODE PLAN - BASEMENT AREA A

LS001.2 CODE PLAN - BASEMENT AREA B

LS001.3 CODE PLAN - BASEMENT AREA C

LS001.4 CODE PLAN - BASEMENT AREA D

LS001.5 CODE PLAN - BASEMENT AREA E

LS100 CODE PLAN - FIRST FLOOR OVERALL

LS100.1 CODE PLAN - FIRST FLOOR AREA A

LS100.2 CODE PLAN - FIRST FLOOR AREA B

LS100.3 CODE PLAN - FIRST FLOOR AREA C

LS100.4 CODE PLAN - FIRST FLOOR AREA D

LS100.5 CODE PLAN - FIRST FLOOR AREA E

LS200 CODE PLAN - SECOND FLOOR OVERALL

LS200.1 CODE PLAN - SECOND FLOOR AREA A

LS200.2 CODE PLAN - SECOND FLOOR AREA B

LS200.3 CODE PLAN - SECOND FLOOR AREA C

LS200.4 CODE PLAN - SECOND FLOOR AREA D

LS200.5 CODE PLAN - SECOND FLOOR AREA E

LS300 CODE PLAN - THIRD FLOOR OVERALL

LS300.1 CODE PLAN - THIRD FLOOR AREA A

LS300.2 CODE PLAN - THIRD FLOOR AREA B

LS300.3 CODE PLAN - THIRD FLOOR AREA C

LS300.4 CODE PLAN - THIRD FLOOR AREA D

LS300.5 CODE PLAN - THIRD FLOOR AREA E

LS400 CODE PLAN - FOURTH FLOOR OVERALL

LS500 CODE PLAN - FIFTH FLOOR OVERALL

LS600 CODE PLAN - SIXTH FLOOR OVERALL

LS700 CODE PLAN - PENTHOUSE OVERALL

N

ARM

SIGNAL

A R M

S

IG

N A L

S

IG

N A L

A R M

ARM

SIGNAL

S

D

PARKING

HOSPITAL DRIVE

T

IG

E R

A V

E

ACCESSIBLE PARKING

E STADIUM

BLVD

M O

N K

D R

GENERAL STORAGE

BLDG. #16

BUTLER BUILDING

CHILLER PLANT BLDG.

#23

SHIPPING WAREHOUSE

PATIENT TOWER

PENTHOUSE

HOSPITAL

BUILDING

ACA BUILDING

BULK OXYGEN TANK

SPEED BUMP TYP.

TRANSFORMERS

FD CONNECTION

BLDG. 19

BLDG. 21

MAINTENANCE SHED #15

FD CONNECTION

FACILITIES

MANAGEMENT

BUILDING #22

PARKING GARAGE

FENCE

STAFF PARKING

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

LS000

CODE PLAN - SITE

CORRECT FIRE & LIFE

SAFETY DEFICIENCIES -

LIFE SAFETY PLANS

800 HOSPITAL DRIVE COLUMBIA, MO 65201

01-31-2020

589A4-19-104

100% CONSTRUCTION DOCUMENTS

1" = 20'-0"

8 - SITE - (PARENT)

N

FEC

F E

C

MECH. ROOM

AIR WAY

STORAGE

MECH. ROOM

CORRIDOR

STORAGE

BOILER

ROOM

STORAGE

PIPES MECH.

SHOP

STORAGE

STORAGE

STORAGE

ELEC. ROOM

MECH. ROOM

ACCESS

TUNNEL

OPEN TO

ABOVE

HATCHED AREAS ARE

UNPAVED CRAWLSPACE

HATCHED AREAS ARE

UNPAVED CRAWLSPACE

HATCHED AREAS ARE

UNPAVED CRAWLSPACE

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

WALL

RATING

NEW

PARTITION KEY

NFPA

101-2018

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER2

HR

MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

HR

MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER2

HR

MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)

(1/2 HR = EXIST. ENCL. IN EXIST BLD'G)

1 HR

2 HR

MIN

MIN

HAZ./INCIDENTAL

USE

FIRE BARRIER

1 HR 45

MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS

(SPRINKLERED)

NR-

RESIST

SMK

NR

SELF OR AUTO

CLOSING

SUBDIVIDING

SPACES

SMOKE BARRIER

(I-2 OCCUPANCY)

MIN

1/2 HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

NR

*NR

SELF OR AUTO

CLOSING

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

NR

1 HR

VERT. OPG. (SHAFT)

FIRE BARRIER

MIN

1 HR

2 HR

MIN

MINEXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

6.1.14.4.1 19.1.3.5.1

7.2.4.1.3 (1) 19.1.3.8 19.2.2.5 7.1.3.2.1

19.3.1.1-8 8.6

8.7.1 19.3.2.1

8.5

8.4.2 19.2.5.7.1.4

8.4.2 19.3.6.2

21.3.6 35.3.6

19.3.1

7.2.6

8.2.1.3

8.6

19.2.2.7

8.6

19.3.2.1.2

19.3.7.3

7.2.1.4.1 7.2.4.3.7 8.3.4 19.2.2.5, 1-4

8.3.3.2.2 TBL

19.2.2.2

7.1.3.2 (9)

8.3.3.2.2 TBL

19.3.2.1.3

8.3.3.2.2 TBL

8.5.4 19.3.7.8

8.3.3.2.2 TBL

19.2.2.2.

8.3.3.2.2 TBL

8.3.3.2.2 TBL

8.3.3.2.2. TBL

8.7.1.3 8.4.3 19.3.2.1.3

19.3.6.3.2 8.4.3

19.3.6.3 8.4.3

N/A

FIRE 90

MIN

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR ONLY

N/A

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLO

WED

8.3.4.8 9.2.1

8.3.4.8 9.2.1

8.3.4.8 9.2.1 7.2.4.3.5

N/A

8.5.5.3 19.3.7.3(2)

8.6.4.5

N/A

N/A

8.4.4

8.4.4 8.4.6.2

8.4.4.1 8.4.6.2 19.3.6.4.2

N/A

SYMBOLS

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

OCC.

LOAD

FACTOR

FIRE ALARM CONTROL PANEL

FIRE SYSTEM ANNUNCIATOR ALARM

ANNUNCIATOR PANEL

FACP

FSA

FAA

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

ACTUAL

EXIT

WIDTH

NO. OF OCC./

NO. OF EXITS

1:50

10/1

2"

34"

FEC

FP

PROPERTY LINE

TD = XX

STARTING

LOCATION

TRAVEL DISTANCE

TRAVEL

PATH

FE

FIRE EXTINGUISHER CABINET

FIRE PULL STATION

FIRE EXTINGUISHER

NOTES

[A] DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS

OF SMOKE BARRIERS WHERE HVAC SYSTEMS ARE FULLY

DUCTED (19.3.7.3x2)

[B] AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL

HAVE DAMPERS (NFPA 8.2.4.4.3)

[C] SMOKE DAMPERS ARE NOT REQUIRED WHERE

OPENINGS IN DUCT ARE LIMITED TO A SINGLE SMOKE

COMPARTMENT & DUCTS ARE MADE OF STEEL

[D] TRANSFER GRILLES, REGARDLESS OF WHETHER THEY

ARE PROTECTED, ARE NOT ALLOWED IN THESE DOORS OR

WALLS (NFPA 19.3.6.4)

10/1

2"

34"

SUB BASEMENT KEY PLAN

A

BC

D

E

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

LS000.5

CODE PLAN - SUB BASEMENT

OVERALL

CORRECT FIRE & LIFE

SAFETY DEFICIENCIES -

LIFE SAFETY PLANS

800 HOSPITAL DRIVE COLUMBIA, MO 65201

01-31-2020

589A4-19-104

100% CONSTRUCTION DOCUMENTS

Not to Scale

-1 - SUB BASEMENT - (PARENT)

N

BLDG. 1 - OCCUPANCY 1

SUB BASEMENT = 32,825 S.F.

OCCUPANCY TYPE - STORAGE

TYPE II (222) CONSTRUCTION

TOTAL OCCUPANTS ________

FLOORS BELOW THE STREET

FLOOR USED FOR OTHER THAN

BUSINESS OCCUPANCY SHALL

HAVE NO UNPROTECTED

OPENING TO BUSINESS

OCCUPANCY FLOORS.

COMPLIANCE NOTE

PER NFPA

39.3.1.2

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

F E

C F

E C

FEC

FEC

F E

C

F E

C

F E

C

FEC

FEC

FEC FEC

FEC

FEC

FEC

FEC

FEC

FEC

FEC

F E

C

FEC

F E

C

FEC

FEC

FEC

F E

C

FEC

FEC

F E

C

F E

C

F E

C

FEC

F E

C

FEC

F E

C

FEC

FEC

FEFEFE

FE

F E

FE

F E

FE

FE

F E

FE

F E

C

FEC

F E

C

JT

JT

JT

JT

JT

F E

C

FEC

IN VITRO

CELL TEST

LAB.

F016

MRI

CONTROL

F017

RADIOPHARMACEUTICAL

R&D

F018

CORR.

CBF3

HOT CELL

F020

CYLINDER

STG.

F015

RADIONUCLIDE

GENERATOR

LAB

F022

EQUIP. RM.

F023

GEN.

RADIOCHEMISTRY/

PEPTIDE

SYNTHESIS/

PEPTIDE

RADIOLABELING

F004

VEST.

F023A

GLASS WASH

F024

WORK ROOM

F026

CORR.

CBF2

VEST.

F025A

OFFICE

F025

TISSUE

CULTURE

(COLD)

F028A

IMMUNOLOGY

LAB.

F027

CYLINDER

STG.

F027A

TISSUE PREP.

(HOT)

F029

TISSUE

CULTURE

(HOT)

F029A

CAMERA

DARK RM.

F031

MICRO DARK

RM.

F032

OFFICE

F033

OFFICE

F034

ELECTRICAL

CLOSET

F001B

VEST.

F002A

RADIOPHARMACEUTICAL

R&D

F010

JAN.

F036

CHIEF

PHARM. SVC.

E002M

ELEC. ROOM

E009

TELE./ DATA.

E006

Room

E003B

ELEV. LOBBY

CBE5

STG.

E005

CORR.

CBE4

ELEV.

#11

ELEV. MACH.

RM.

E007

CONF. RM.

E002E

PROG.

SUPPORT,

R&D

E002C

WK. RM.

E002B

R.C.O., R&D

E002I

RSCH. SVC.

CORR

E002

STAGING RM.

E001D

ANTE RM.

E001C

ANIMAL

WARD

A027A

ANIMAL

WARD

A027

ANIMAL

WARD

A030

CORR.

CBA7

ANIMAL

WARD

A029

RSCH. WK.

RM.

A010

CLOSET

A010A

RADIOPHARMACY

RSCH.

A009

RADIOPHARMACY

RSCH.

A007

GLASS WASH

B051

PHARMACOLOGY

RSCH.

B048

PHARMACOLOGY

RSCH.

B042

OFFICE

B049

RSCH.

COMMON RM.

B045

OFFICE

B017

RSCH.

INVESTIGATOR

B022

RSCH.

INVESTIGATOR

B015

CORR.

CBA14

RADIOPHARMACY

RSCH.

A004

CORR.

CBA1

CHIEF

B006A

ASSOC.

CHIEF

B006B

RSCH.

INVESTIGATOR

B012

OFFICE

B010

ELEC.

CLOSET

B009A

ELEC.

CLOSET

B009B

LACTATION

B009

CLASSROOM

B007ON-CALL

ROOMS/LOUNGE

B011

OFFICE

B010A

OFFICE

B016

RADIOPHARMACY

RSCH.

A003

CORR.

CBA2

RADIOPHARMACY

RSCH.

A006

ONCOLOGY

RESCH.

A051 RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A049

RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A016A

CORR.

CBA10

RSCH. STG.

A054

RADIATION

LAB.

A052

RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A050

RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A047

DMARC

A060

CART WASH

(DIRTY)

A046

ELEC.

CLOSET

A047A

CORR.

CBA6

SHR./ LNGE.

A011

ANIMAL

X-RAY RM.

A015

DARK RM.

A015A

RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A017

ANIMAL

WARD

A045

VMU OFFICE

A043

ANIMAL

WARD

A033

ANIMAL

WARD

A035

ANIMAL

WARD

A032

ANIMAL

WARD

A034

CORR.

CORR.

CBA9

CLOSET

A025BFIRE CL.

CBA2A

STG. RSCH.

SVC.

A033

FUTURE

ANIMAL

WARD

A037

EQUIP. STG.

A036ANIMAL

WARD

A039

ANIMAL

WARD

A040

LOUNGE

A063

CORR.

CBA11

CORR.

CBA17

SAFETY/EMERGENCY

D005A

OFFICE

D005

PAINT SHOP

D006

OFFICE

D004D

LAUNDRY &

MENDING

D004C

TELEPHONE

OPERATORS

D004L

TLT.

D004B

LAUNDRY

STORAGE

D004F

OFFICE

D004G

EQUIP. STG.

D003B

OFFICE

D004H

LINEN

D004

TECH. MED

REPAIR

D008

FURNITURE

STG.

D009

ELEC. SHOP

D007

CARPENTER

SHOP

D011

OFFICE

D010

TOOL STG.

D011A

KEY SHOP

D012

PIPE &

MECHANICS

SHOP

D016

FIRE SPKLR.

PUMP RM.

D017

OFFICE

D004K

OFFICE

D004J

OFFICE

D004I

EQUIP. STG.

D003C

STORAGE

D003D

CORR.

CBD7

STG.

D003A

STG.

D004O

LOST AND

FOUND

D004N

M. TLT.

D004A

TELEPHONE

OPERATOR

SUPER.

D004E

ENTR. VEST.

D004M

STAIR #5

D015

VEST.

D014

UNISEX TLT.

D013

ELEC.

CLOSET

CBD2B

CORR.

CBD2

BOILER

D018

A/C SHOP

D019C

CORR.

CBD1

REPRODUCTIVE

D002TRASH

D001

TRASH

D001B

JAN.

D001A

JAN.

D029

GROSS SPEC.

D028

LKR./ TLT.

RM.

D027

CORR.

CBD5

ELEV. MACH.

RM.

D025

E.C.C. OFFICE

D019A

STORAGE

D019B

CONTROL

CTR.

D019D

CORR.

D019

SWITCH

GEAR RM.

D020

AUTOPSY

D031

Room

CBD4

COLD RM.

D030

OFFICE

D024

TLT.

D019C

ST. LNGE.

C003A

OFFICE

C003B

TECH.

SUPERVISOR

OFFICE

C003C

TRANSFORMER

RM.

D023

ELEC.

CLOSET

D022

GENERATOR

D022A

ELEC. EQUIP.

D022D

PARALLELING

SWITCHGEAR

D022C

GENERATOR

D022B

SWING SHIFT

SUPERVISOR

C003D

PROGRAM

MANAGER

C003F

LOGISTICS.

VISN 15

SUPPLY

TECHS

C003

CANTEEN

OFFICE

C004C

LOGISTICS

STORAGE

C003E

STAIR #7

C006

OXYGEN STG.

C005A

PHARM. STG.

C004

STORAGE

C004A CANTEEN

STG.

C004B

PHARM. STG.

C004D

LOADING

DOCK

CBC1A

CORR.

CBC1

HAC

C009H

MOW OFFICE

C009I

MOW OFFICE

C009K

FOOD STG.

C009GCORR.

C009J

BIOMEDICAL

ENG.

C002

FOOD PREP

C009

REF.

C009D

JAN.

B002E

OFFICE

B002F

MECH.

C012

FOOD PREP./

COOK

B001B

CART CLEAN

B001C

SHEET

METAL SHOP

C013

LOGISTICS

OFFICE

W05

ELEC. RM.

G008

OFFICE

G019

CHIEF OF

SERVICE

C001A

TLT

B011H

DIETETICS

STG.

B002G

TRNG/BRK.

RM.

B002D

DIETETICS

OFFICE

B002A

RSCH. CORE

AREA

B019

CLOSET

B026A

TRANS. RM.

B027A

PULMONARY

RSCH.

B027

OFFICE

B033

STAIR #3

BO36A

ELEC.

CLOSET

B030

CORR.

CBB3

LAB.

B026

LAB.

B023

MECH. ROOM

E003A

MECH. ROOM

E003

FRZ.

F030A REF.

F030

ELEC.

CLOSET

F035

F.A.

CONTROL

PANEL

F035A

VEST.

F034A

TISSUE PREP.

(COLD)

F028

MRI ROOM

F019

CORR.

F015A

RADIO

PHARM./

PHARMAKINETIC

LAB.

F014

HOT LAB. 1

F021

COLD LAB.

F005

CONF. RM.

F001A

RECP.

F001

CORR.

CBF5

WORK ROOM

F002

OFFICE

F003

WORK ROOM

F006

OFFICE

F007

OFFICE

F008

OFFICE

F009

VEST.

F009A

SHARED

OFFICE

F011

VA-BIC PET/

SPECT/

CT/MOLECULAR

IMAGING

SUITE

F012

CORR.

CBF4

STG.

F013

STAIR #11

#11

JAN.

E012

ELEV. MACH.

RM.

E004

M. TLT.

E008

W. TLT.

E010 PHARM.

E001

STORAGE

E001G

STER./ IV

PREP.

E001B

NARCOTIC

VAULT

E001A

PHARM. SVC.

E002N

ANTI-COAGULATION

OFFICE

E002Q

ADMIN.

OFFICER

PHARM.

E002O

SUPV.

INPATIENT

PHARM.

E001F

OUTPATIENT

PHARM.

SUPV.

E001E

HALL

E001H

BREAK RM.

E002F

A.O., R&D

E002D

CORR.

CBE2

CORR.

CBE1

OFFICE

E002A

OFFICE

E002H

CLINICAL

RSCH.

E002J

M.F.M.R.

EXECUTIVE

DIR.

E002K

OFFICE

E002L

CORR.

CBE3

OPHTHALMOLOGY

RSCH.

B032

COLD RM.

B037A

COLD RM.

B037

STAIR

ACCESS

B036

SIGNAL

PANELS

B033A

JAN.

B034

CORR.

CBB3

PHARMACOLOGY

RSCH.

B039

OFFICE

B039A

HEALTH

PHYSICS LAB.

B050

RSCH.

OFFICE

B046

RSCH.

INVESTIGATOR

B047

OFFICE

B046A

RSCH.

INVESTIGATOR

B021

OFFICE

B006

OFFICE

B006C

CORR.

B020

OFFICE

B014

OFFICE

B018

OPHTHALMOLOGY

B031

OFFICE

B025B

RHEUMATOLOGY

RSCH.

B024

HAS

B013

CORR.

CBB1

ON-CALL RM.

#1

B011A

TLT

B011B

ON-CALL RM.

#2

B011C

ON-CALL RM.

#3

B011D

TLT

B011E

ON-CALL RM.

#4

B011F

ON-CALL RM.

#5

B001G

ELEC. ROOM

B011J

ON-CALL

ROOMS/LOUNGE

B011

CLEANING

AREA

B001A

VTS/TRVL

SUPERVISOR

B013A

ELEV. MACH.

RM.

G004A

EQUIP.

G004

ELEV.

#12

ELEV.

#13

ELEV.

#10

ELEV.

#9

ELEV.

#14

ELEV.

CONTROL

G015

CORR.

CBG6

CART WASH

G035

DIRTY

PROCESSING

G032

EQUIP.

G052B

ELEV.

CONTROL

G016

OFFICE &

SUPPLY

G051

STERILIZER

ACCESS

ROOM

G052C

ETO

STERILIZER

ACCESS

G045

STERILIZER

ACCESS

G043A

HALL

G046

ELEC. ROOM

G013

CORR.

CBG2

OFFICE

G019A

STG

G019B

OFFICE

G019C

SHOWER

G040A

CONTROL

ROOM

G042

HALL

G037

HALL

G023

HALL

CBG4

CONFERENCE

R00M

G017

WOMEN'S

LOCKER

G024

MEN'S

LOCKER

G027

MEN'S

SHOWER

G027A WOMEN'S

SHWR

G024B

STORAGE

G029

STORAGE

G030

CORR.

CBG3

WAREHOUSE

BREAKOUT

AREA

W03

WAREHOUSE

W07

TOILET

W08

LOGISTICS

MANAGER

W09

CLOSET

W05B

SHIPPING

AND

RECEIVING

W02

PHARMACY

DRUG CACHE

W03A

CORR.

W03B

OFFICE

B001F

DISH CLEAN

B002

DISH CLEAN

B002K

CLOSET

B001E

DIETETICS

OFFICE

C009A

REF.

C009B

OFFICE

C009C

FRZ.

C009F

REF.

C009E

MECH. EQUIP.

C010

TLT.

C009M

TLT.

C009N

CORR.

C009J

OFFICE

C008

BIOMEDICAL

SUPV.

C002B

BIOMED

STORAGE

C002A

OI&T

C001

ELEV.

#8

ELEV.

#7

ELEV.

#4

ELEV.

#5

MECH.

CHASE

C001D

ELEV. LOBBY

A058

ELEV.

#3

ELEV.

#2

ELEV.

#1

CORR.

CBA13

BIOHAZARD

STG.

A057

CLOSET

A059A

MAIL RM.

A059

STAIR #1

A056

IT CLOSET

A056A

CLOSET

A054B

ELEC.

CLOSET

A053

RSCH.

INVESTIGATOR

A048

MEN'S

LOCKER

A063C

MEN'S TLT

A063B

FITNESS

A063A

WOMAN'S TLT

A063E

WOMAN'S

SHWR

A063F

WOMAN'S

LOCKER

A063G

MECH RM.

A038

STG.

A033B

STG. RSCH.

A033A

CORR.

CBA8

CAGE WASH

A041

F. TLT.

A001

M. TLT.

A002

PHY. RSCH.

A009A

ENDOCRINE/

HYPERTENSION

RSCH.

A019

ENDOCRINE/

HYPERTENSION

RSCH.

A020

RSCH.

OFFICE

A020A

OFFICE

A022

STAIR #4

A024A

JAN.

A025

CORR.

CBA5

STAIR CORR.

A024

PATHOGEN

FREE SUITE

A026

ANIMAL

WARD

A028

ANIMAL

WARD

A031

STG.

A042

STG.

A042A

OFFICE

A023A

NEURO.

SLEEP RSCH.

A023

SURG. SUITE

A021

ANIMAL

SURG.

A045A

NEURO.

SLEEP RSCH.

A018

COLD. RM.

A014

CORR.

CBA4

ENDOCRINE/

HYPERTENSION

RSCH.

A012

RSCH.INVESTIGATOR

A013

PHY. RSCH.

A008

ANIMAL

WARD

A008A

RSCH.

INVESTIGATOR

A005

OFFICE

A004A

RADIOPHARMACY

RSCH.

A055

OFFICE

A006A

OFFICE

A051A

RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A016

BREAK ROOM

G018

WOMEN'S TLT

G024A

FILTER

EQUIPMENT

G052A

VESTIBULE

G031

ANTE ROOM

G059

CORR.

G055

STAIR #12

G060

ELEV. LOBBY

G026

CORR.

CBG5

MANUAL

WASH RM.

G032A

C/S WORK

AREA

G052

ENDOSCOPE

PROCESS.

G036

ELEV.

#15

STORAGE

G050

CLEAN

RECEIVING

BREAKOUT

G048

BULK STORE

RM

G047

CLEAN

PROCESSING

G043

MECH. RM.

G001

CORR.

G012

LOCKERS

G038

SHOWER

G038A

LOCKERS

G040

WAREHOUSE

W04A

WAREHOUSE

W04

WAREHOUSE

W05A

CANTEEN

STOCKROOM

W06

PROCESS

STORES

W01

STG.

C014

CORR.

CBC3

937/10

28.2"

46"

STAIR #1

850/16

15.9"

46"

937/10

28.2"

46"

937/10

28.2"

46"

850/16

15.9"

46"

850/16

15.9"

46"

247/2

24.6"

46"

STAIR #6

STAIR #7

STAIR #3

STAIR #11

STAIR #4

STAIR #5

RECEPTION

E002

MEN'S SHWR

A063D

MAKE-UP

A063H

KITCHEN

PREP. AREA

B001D

L S

.5

E

LS001.4 "D

LS001.3 "C

LS001.2 "B

LS001.5 "E

LS00

1.

1 "A

LS00

1.

2 "B

LS001.1 "A

LS001.3 "C

L S

.4

D

937/10

18.8"

69"

937/10

18.8"

46.5"

937/10

18.6"

40.5"

STAIR #7

EXITS THIS LEVEL

OPEN TO

BOILER RM

BELOW

EXIT

STAIR #9 EXITS

THIS LEVEL

STAIR #5 EXITS

THIS LEVEL

STAIR #6 EXITS

THIS LEVEL

BLDG 1 -

OCC. 3

BLDG 2 -

OCC. 4

BLDG 1 -

OCC. 3

BLDG 2 -

OCC. 4

COMPLIANCE NOTE PER NFPA

7.7.2

STAIR #1 SHALL BE

PERMITTED TO

DISCHARGE THROUGH

AREA OF LEVEL OF EXIT

DISCHARGE.

937/10

18.8"

69"

937/10

18.8"

61"

EXIT

NOT

AN

EXIT

937/10

18.6"

34.5"

29/2

3"

73"

TD = 105'-0"

TD = 141'-0"

T D

T D

TD = 147'-5"

TD = 261'-2"

T D

T D

T D

TD = 188'-8"

TD = 118'-6"

TD = 179'-6"

T D

471/13

10.8

42.5"

29/2

2.8"

40.5"

BASEMENT NOTE

MAXIMUM TRAVEL

DISTANCE TO EXIT = 300'-0"

IN BUSINESS OCCUPANCY

AREAS

(IF SPRINKLERED)

COMPLIANCE NOTE PER NFPA

19.1.3.7

ALL MEANS OF EGRESS FROM HEALTHCARE

OCCUPANCIES THAT TRAVERSE NON-

HEALTHCARE OCCUPANCIES SHALL

CONFORM TO THE REQUIREMENTS OF THE

CODE FOR HEATHCARE OCCUPANCIES.

BASEMENT NOTE

MAXIMUM TRAVEL

DISTANCE TO EXIT = 300'-0"

IN BUSINESS OCCUPANCY

AREAS

(IF SPRINKLERED)

CHILLER PLANT

PASSAGE UNDER

HOSPITAL DRIVE TO

OTHER HOSPITAL

LS001.2 "B

LS001.5 "E

L S

.3

C

L S

.2

B

TD = 165'-6

TD = 188'-8"

T D

247/2

24.8"

80"

247/2

24.8"

80"

STAIR #9

TOTAL OCCUPANTS EXIT THIS

AREA + 1/2 FROM LAB AREA

ELEV.

BLDG. 22

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

WALL

RATING

NEW

PARTITION KEY

NFPA

101-2018

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER2

HR

MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

HR

MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER2

HR

MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)

(1/2 HR = EXIST. ENCL. IN EXIST BLD'G)

1 HR

2 HR

MIN

MIN

HAZ./INCIDENTAL

USE

FIRE BARRIER

1 HR 45

MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS

(SPRINKLERED)

NR-

RESIST

SMK

NR

SELF OR AUTO

CLOSING

SUBDIVIDING

SPACES

SMOKE BARRIER

(I-2 OCCUPANCY)

MIN

1/2 HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

NR

*NR

SELF OR AUTO

CLOSING

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

NR

1 HR

VERT. OPG. (SHAFT)

FIRE BARRIER

MIN

1 HR

2 HR

MIN

MINEXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

6.1.14.4.1 19.1.3.5.1

7.2.4.1.3 (1) 19.1.3.8 19.2.2.5 7.1.3.2.1

19.3.1.1-8 8.6

8.7.1 19.3.2.1

8.5

8.4.2 19.2.5.7.1.4

8.4.2 19.3.6.2

21.3.6 35.3.6

19.3.1

7.2.6

8.2.1.3

8.6

19.2.2.7

8.6

19.3.2.1.2

19.3.7.3

7.2.1.4.1 7.2.4.3.7 8.3.4 19.2.2.5, 1-4

8.3.3.2.2 TBL

19.2.2.2

7.1.3.2 (9)

8.3.3.2.2 TBL

19.3.2.1.3

8.3.3.2.2 TBL

8.5.4 19.3.7.8

8.3.3.2.2 TBL

19.2.2.2.

8.3.3.2.2 TBL

8.3.3.2.2 TBL

8.3.3.2.2. TBL

8.7.1.3 8.4.3 19.3.2.1.3

19.3.6.3.2 8.4.3

19.3.6.3 8.4.3

N/A

FIRE 90

MIN

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR ONLY

N/A

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLO

WED

8.3.4.8 9.2.1

8.3.4.8 9.2.1

8.3.4.8 9.2.1 7.2.4.3.5

N/A

8.5.5.3 19.3.7.3(2)

8.6.4.5

N/A

N/A

8.4.4

8.4.4 8.4.6.2

8.4.4.1 8.4.6.2 19.3.6.4.2

N/A

SYMBOLS

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

OCC.

LOAD

FACTOR

FIRE ALARM CONTROL PANEL

FIRE SYSTEM ANNUNCIATOR ALARM

ANNUNCIATOR PANEL

FACP

FSA

FAA

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

ACTUAL

EXIT

WIDTH

NO. OF OCC./

NO. OF EXITS

1:50

10/1

2"

34"

FEC

FP

PROPERTY LINE

TD = XX

STARTING

LOCATION

TRAVEL DISTANCE

TRAVEL

PATH

FE

FIRE EXTINGUISHER CABINET

FIRE PULL STATION

FIRE EXTINGUISHER

NOTES

[A] DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS

OF SMOKE BARRIERS WHERE HVAC SYSTEMS ARE FULLY

DUCTED (19.3.7.3x2)

[B] AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL

HAVE DAMPERS (NFPA 8.2.4.4.3)

[C] SMOKE DAMPERS ARE NOT REQUIRED WHERE

OPENINGS IN DUCT ARE LIMITED TO A SINGLE SMOKE

COMPARTMENT & DUCTS ARE MADE OF STEEL

[D] TRANSFER GRILLES, REGARDLESS OF WHETHER THEY

ARE PROTECTED, ARE NOT ALLOWED IN THESE DOORS OR

WALLS (NFPA 19.3.6.4)

10/1

2"

34"

BASEMENT KEY PLAN

A

BC

D

E

SMOKE

COMPARTMENT #0-0

170002 SF0-0

BASEMENT

19672008

(CH. 39)

EXISTG. BUSINESS

(CH. 39)

EXISTG. BUSINESS

(CH. 42)

EXISTG. STORAGE

(CH. 39)

EXISTG. BUSINESS

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

LS001

CODE PLAN - BASEMENT OVERALL

CORRECT FIRE & LIFE

SAFETY DEFICIENCIES -

LIFE SAFETY PLANS

800 HOSPITAL DRIVE COLUMBIA, MO 65201

01-31-2020

589A4-19-104

100% CONSTRUCTION DOCUMENTS

Not to Scale

0 - BASEMENT - (PARENT)

N

BLDG. 1 - OCCUPANCY 3

BASEMENT = 158,877 S.F.

OCCUPANCY TYPE - BUSINESS

TYPE II (222) CONSTRUCTION

TOTAL OCCUPANTS 1060

FULLY SPRINKLERED

HAZARDOUS AREAS IN FULLY

SPRINKLERED BUILDINGS ARE

NOT REQUIRED TO BE

PROTECTED BY FIRE BARRIERS.

COMPLIANCE NOTE

PER NFPA

3.9.3.2.1 &

8.7.1.1 (2)

ALL MEANS OF EGRESS FROM

HEALTHCARE OCCUPANCIES THAT

TRAVERSE NON-HEALTHCARE

OCCUPANCIES SHALL CONFORM TO

THE REQUIREMENTS OF THE CODE

FOR HEATHCARE OCCUPANCIES.

COMPLIANCE NOTE

PER NFPA

19.1.2.4

BLDG. 2 - OCCUPANCY 4

BASEMENT = 14,193 S.F.

OCCUPANCY TYPE - STORAGE

TYPE II (000) CONSTRUCTION

TOTAL OCCUPANTS 29

FULLY SPRINKLERED

STORAGE OCCUPANCY

OCCUPANCY LOAD FACTOR N/A

(USED OCC. GROSS / 500)

14,193 / 500 = 29 OCC.

COMPLIANCE NOTE PER NFPA

7.3.1.2

14,775 SF / 500 = 30 OCC.

BUSINESS OCCUPANCY

OCCUPANCY LOAD FACTOR 150

158,877 / 150 = 1060 OCC.

COMPLIANCE NOTE PER NFPA

7.3.1.2

F E

C F

E C

FEC

FEC

F E

C

F E

C

F E

C

FEC

FEC

FEFEFE FE

F E

C

FEC

F E

C

FEC

IN VITRO

CELL TEST

LAB.

F016

MRI

CONTROL

F017

RADIOPHARMACEUTICAL

R&D

F018

CORR.

CBF3

HOT CELL

F020

CYLINDER

STG.

F015

RADIONUCLIDE

GENERATOR

LAB

F022

EQUIP. RM.

F023

GEN.

RADIOCHEMISTRY/

PEPTIDE

SYNTHESIS/

PEPTIDE

RADIOLABELING

F004

VEST.

F023A

GLASS WASH

F024

WORK ROOM

F026

CORR.

CBF2

VEST.

F025A

OFFICE

F025

TISSUE

CULTURE

(COLD)

F028A

IMMUNOLOGY

LAB.

F027

CYLINDER

STG.

F027A

TISSUE PREP.

(HOT)

F029

TISSUE

CULTURE

(HOT)

F029A

CAMERA

DARK RM.

F031

MICRO DARK

RM.

F032

OFFICE

F033

OFFICE

F034

ELECTRICAL

CLOSET

F001B

VEST.

F002A

RADIOPHARMACEUTICAL

R&D

F010

JAN.

F036

CHIEF

PHARM. SVC.

E002M

ELEC. ROOM

E009

TELE./ DATA.

E006

Room

E003B

ELEV. LOBBY

CBE5

STG.

E005

CORR.

CBE4

ELEV.

#11

ELEV. MACH.

RM.

E007

CONF. RM.

E002E

PROG.

SUPPORT,

R&D

E002C

WK. RM.

E002B

R.C.O., R&D

E002I

RSCH. SVC.

CORR

E002

STAGING RM.

E001D

ANTE RM.

E001C

ANIMAL

WARD

A027A

RSCH. WK.

RM.

A010

CLOSET

A010A

RADIOPHARMACY

RSCH.

A009

RADIOPHARMACY

RSCH.

A007

GLASS WASH

B051

PHARMACOLOGY

RSCH.

B048

PHARMACOLOGY

RSCH.

B042

CORR.

CBA14

RADIOPHARMACY

RSCH.

A003

CLOSET

A025BFIRE CL.

CBA2A

OFFICE

B033

STAIR #3

BO36A

MECH. ROOM

E003A

MECH. ROOM

E003

FRZ.

F030A REF.

F030

ELEC.

CLOSET

F035

F.A.

CONTROL

PANEL

F035A

VEST.

F034A

TISSUE PREP.

(COLD)

F028

MRI ROOM

F019

CORR.

F015A

RADIO

PHARM./

PHARMAKINETIC

LAB.

F014

HOT LAB. 1

F021

COLD LAB.

F005

CONF. RM.

F001A

RECP.

F001

CORR.

CBF5

WORK ROOM

F002

OFFICE

F003

WORK ROOM

F006

OFFICE

F007

OFFICE

F008

OFFICE

F009

VEST.

F009A

SHARED

OFFICE

F011

VA-BIC PET/

SPECT/

CT/MOLECULAR

IMAGING

SUITE

F012

CORR.

CBF4

STG.

F013

STAIR #11

#11

JAN.

E012

ELEV. MACH.

RM.

E004

M. TLT.

E008

W. TLT.

E010 PHARM.

E001

STORAGE

E001G

STER./ IV

PREP.

E001B

NARCOTIC

VAULT

E001A

PHARM. SVC.

E002N

ANTI-COAGULATION

OFFICE

E002Q

ADMIN.

OFFICER

PHARM.

E002O

SUPV.

INPATIENT

PHARM.

E001F

OUTPATIENT

PHARM.

SUPV.

E001E

HALL

E001H

BREAK RM.

E002F

A.O., R&D

E002D

CORR.

CBE2

CORR.

CBE1

OFFICE

E002A

OFFICE

E002H

CLINICAL

RSCH.

E002J

M.F.M.R.

EXECUTIVE

DIR.

E002K

OFFICE

E002L

CORR.

CBE3

COLD RM.

B037A

COLD RM.

B037

STAIR

ACCESS

B036

SIGNAL

PANELS

B033A

JAN.

B034

PHARMACOLOGY

RSCH.

B039

OFFICE

B039A

ELEV.

#10

ELEV.

#9

F. TLT.

A001

M. TLT.

A002

PHY. RSCH.

A009A

ENDOCRINE/

HYPERTENSION

RSCH.

A019

ENDOCRINE/

HYPERTENSION

RSCH.

A020

RSCH.

OFFICE

A020A

OFFICE

A022

STAIR #4

A024A

JAN.

A025

STAIR CORR.

A024

PATHOGEN

FREE SUITE

A026

937/10

28.2"

46"

937/10

28.2"

46"

247/2

24.6"

46"

STAIR #3

STAIR #11

STAIR #4

RECEPTION

E002

LS001.1

"A

LS001.2

"B

LS

001.1 "A"

LS

001.3 "C

EXIT

TD = 261'-2"

T D

T D

T D

PASSAGE UNDER

HOSPITAL DRIVE TO

OTHER HOSPITAL

L S

.3

C

L S

.2

B

T D

247/2

24.8"

80"

247/2

24.8"

80"

SMOKE

COMPARTMENT #0-0

170002 SF0-0

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

WALL

RATING

NEW

PARTITION KEY NFPA 101-2018

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER

2 HR

90 MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

2 HR

90 MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER

2 HR

90 MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)

(1/2 HR = EXIST. ENCL. IN EXIST BLD'G)

1 HR

2 HR

60 MIN

90 MIN

HAZ./INCIDENTAL USE

FIRE BARRIER

1 HR 45 MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS

(SPRINKLERED)

NR-

RESIST

SMK

NR

SELF OR AUTO

CLOSING

SUBDIVIDING SPACES

SMOKE BARRIER (I-2 OCCUPANCY)

20 MIN

1/2

HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

NR

*NR

SELF OR AUTO

CLOSING

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

NR

1 HR

VERT. OPG. (SHAFT)

FIRE BARRIER 60 MIN

1 HR

2 HR

60 MIN

90 MINEXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

6.1.14.4.1 19.1.3.5.1

7.2.4.1.3 (1) 19.1.3.8 19.2.2.5 7.1.3.2.1

19.3.1.1-8 8.6

8.7.1 19.3.2.1

8.5

8.4.2 19.2.5.7.1.4

8.4.2 19.3.6.2

21.3.6 35.3.6

19.3.1

7.2.6

8.2.1.3

8.6

19.2.2.7

8.6

19.3.2.1.2

19.3.7.3

7.2.1.4.1 7.2.4.3.7 8.3.4 19.2.2.5, 1-4

8.3.3.2.2 TBL

19.2.2.2

7.1.3.2 (9)

8.3.3.2.2 TBL

19.3.2.1.3

8.3.3.2.2 TBL

8.5.4 19.3.7.8

8.3.3.2.2 TBL

19.2.2.2.

8.3.3.2.2 TBL

8.3.3.2.2 TBL

8.3.3.2.2. TBL

8.7.1.3 8.4.3 19.3.2.1.3

19.3.6.3.2 8.4.3

19.3.6.3 8.4.3

N/A

FIRE

90 MIN

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR

ONLY

N/A

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLOWED

8.3.4.8 9.2.1

8.3.4.8 9.2.1

8.3.4.8 9.2.1 7.2.4.3.5

N/A

8.5.5.3 19.3.7.3(2)

8.6.4.5

N/A

N/A

8.4.4

8.4.4 8.4.6.2

8.4.4.1 8.4.6.2 19.3.6.4.2

N/A

BASEMENT KEY PLAN

A

SYMBOLS

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

OCC. LOAD

FACTOR

FIRE ALARM CONTROL PANEL

FIRE SYSTEM ANNUNCIATOR ALARM

ANNUNCIATOR PANEL

FACP

FSA

FAA

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

ACTUAL EXIT

WIDTH

NO. OF OCC./

NO. OF EXITS

1:50

10/1

2"

34"

FEC

FP

PROPERTY LINE

STARTING

LOCATION

TRAVEL DISTANCE

TRAVEL PATH

FE

FIRE EXTINGUISHER CABINET

FIRE PULL STATION

FIRE EXTINGUISHER

NOTES

[A] DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS OF

SMOKE BARRIERS WHERE HVAC SYSTEMS ARE FULLY DUCTED

(18.3.7.3x2)

[B] AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL

HAVE DAMPERS (NFPA 8.2.4.4.3) (IBC 710.7)

[C] SMOKE DAMPERS ARE NOT REQUIRED WHERE OPENINGS IN

DUCT ARE LIMITED TO A SINGLE SMOKE COMPARTMENT &

DUCTS ARE MADE OF STEEL (IBC 716.5.5)

[D] TRANSFER GRILLES REGARDLESS OF WHETHER THEY ARE

PROTECTED

ARE NOT ALLOWED IN THESE DOORS OR WALLS (NFPA 18.3.6.4)

TD = XX

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

LS001.1

CODE PLAN - BASEMENT AREA A

CORRECT FIRE & LIFE

SAFETY DEFICIENCIES -

LIFE SAFETY PLANS

800 HOSPITAL DRIVE COLUMBIA, MO 65201

01-31-2020

589A4-19-104

100% CONSTRUCTION DOCUMENTS

3/32" = 1'-0"

0 - BASEMENT - AREA A

HAZARDOUS AREAS IN FULLY

SPRINKLERED BUILDINGS ARE

NOT REQUIRED TO BE

PROTECTED BY FIRE BARRIERS.

COMPLIANCE NOTE

PER NFPA

3.9.3.2.1 &

8.7.1.1 (2)

BLDG. 1 - OCCUPANCY 3

BASEMENT = 158,877 S.F.

OCCUPANCY TYPE - BUSINESS

TYPE II (222) CONSTRUCTION

TOTAL OCCUPANTS 1060

FULLY SPRINKLERED

BUSINESS OCCUPANCY

OCCUPANCY LOAD FACTOR 150

158,877 / 150 = 1060 OCC.

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

FEC

FEC FEC

FEC

FEC

FEC

FEC

FEC

FEC

F E

C

F E

C

F E

C

FEC

F E

C

FEFE

FE

F E

FE

FE

F E

C

WK. RM.

E002B

R.C.O., R&D

E002I

ANIMAL

WARD

A027A

ANIMAL

WARD

A027

ANIMAL

WARD

A030

CORR.

CBA7

ANIMAL

WARD

A029

RSCH. WK.

RM.

A010

CLOSET

A010A

RADIOPHARMACY

RSCH.

A009

RADIOPHARMACY

RSCH.

A007

CORR.

CBA14

RADIOPHARMACY

RSCH.

A004

CORR.

CBA1

CHIEF

B006A

ASSOC.

CHIEF

B006B

RADIOPHARMACY

RSCH.

A003

CORR.

CBA2

RADIOPHARMACY

RSCH.

A006

ONCOLOGY

RESCH.

A051 RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A049

RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A016A

CORR.

CBA10

RSCH. STG.

A054

RADIATION

LAB.

A052

RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A050

RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A047

DMARC

A060

CART WASH

(DIRTY)

A046

ELEC.

CLOSET

A047A

CORR.

CBA6

SHR./ LNGE.

A011

ANIMAL

X-RAY RM.

A015

DARK RM.

A015A

RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A017

ANIMAL

WARD

A045

VMU OFFICE

A043

ANIMAL

WARD

A033

ANIMAL

WARD

A035

ANIMAL

WARD

A032

ANIMAL

WARD

A034

CORR.

CORR.

CBA9

CLOSET

A025BFIRE CL.

CBA2A

STG. RSCH.

SVC.

A033

FUTURE

ANIMAL

WARD

A037

EQUIP. STG.

A036ANIMAL

WARD

A039

ANIMAL

WARD

A040

LOUNGE

A063

CORR.

CBA11

CORR.

CBA17

SAFETY/EMERGENCY

D005A

OFFICE

D005

PAINT SHOP

D006

OFFICE

D004D

LAUNDRY &

MENDING

D004C

TELEPHONE

OPERATORS

D004L

TLT.

D004B

LAUNDRY

STORAGE

D004F

OFFICE

D004G

EQUIP. STG.

D003B

OFFICE

D004H

LINEN

D004

TECH. MED

REPAIR

D008

FURNITURE

STG.

D009

ELEC. SHOP

D007

CARPENTER

SHOP

D011

OFFICE

D010

TOOL STG.

D011A

KEY SHOP

D012

PIPE &

MECHANICS

SHOP

D016

FIRE SPKLR.

PUMP RM.

D017

OFFICE

D004K

OFFICE

D004J

OFFICE

D004I

EQUIP. STG.

D003C

STORAGE

D003D

CORR.

CBD7

STG.

D003A

STG.

D004O

LOST AND

FOUND

D004N

M. TLT.

D004A

TELEPHONE

OPERATOR

SUPER.

D004E

ENTR. VEST.

D004M

STAIR #5

D015

VEST.

D014

UNISEX TLT.

D013

ELEC.

CLOSET

CBD2B

CORR.

CBD2

BOILER

D018

A/C SHOP

D019C

CORR.

CBD1

REPRODUCTIVE

D002TRASH

D001

TRASH

D001B

JAN.

D001A

JAN.

D029

GROSS SPEC.

D028

LKR./ TLT.

RM.

D027

CORR.

CBD5

ELEV. MACH.

RM.

D025

E.C.C. OFFICE

D019A

STORAGE

D019B

AUTOPSY

D031

COLD RM.

D030

OFFICE

D024

TLT.

D019C

ST. LNGE.

C003A

SUPV.

INPATIENT

PHARM.

E001F

OUTPATIENT

PHARM.

SUPV.

E001E

OFFICE

E002H

CLINICAL

RSCH.

E002J

M.F.M.R.

EXECUTIVE

DIR.

E002K

OFFICE

E002L

ELEV.

#4

ELEV.

#5

ELEV. LOBBY

A058

ELEV.

#3

ELEV.

#2

ELEV.

#1

CORR.

CBA13

BIOHAZARD

STG.

A057

CLOSET

A059A

MAIL RM.

A059

STAIR #1

A056

IT CLOSET

A056A

CLOSET

A054B

ELEC.

CLOSET

A053

RSCH.

INVESTIGATOR

A048

MEN'S

LOCKER

A063C

MEN'S TLT

A063B

FITNESS

A063A

WOMAN'S TLT

A063E

WOMAN'S

SHWR

A063F

WOMAN'S

LOCKER

A063G

MECH RM.

A038

STG.

A033B

STG. RSCH.

A033A

CORR.

CBA8

CAGE WASH

A041

F. TLT.

A001

M. TLT.

A002

PHY. RSCH.

A009A

ENDOCRINE/

HYPERTENSION

RSCH.

A019

ENDOCRINE/

HYPERTENSION

RSCH.

A020

RSCH.

OFFICE

A020A

OFFICE

A022

STAIR #4

A024A

JAN.

A025

CORR.

CBA5

STAIR CORR.

A024

PATHOGEN

FREE SUITE

A026

ANIMAL

WARD

A028

ANIMAL

WARD

A031

STG.

A042

STG.

A042A

OFFICE

A023A

NEURO.

SLEEP RSCH.

A023

SURG. SUITE

A021

ANIMAL

SURG.

A045A

NEURO.

SLEEP RSCH.

A018

COLD. RM.

A014

CORR.

CBA4

ENDOCRINE/

HYPERTENSION

RSCH.

A012

RSCH.INVESTIGATOR

A013

PHY. RSCH.

A008

ANIMAL

WARD

A008A

RSCH.

INVESTIGATOR

A005

OFFICE

A004A

RADIOPHARMACY

RSCH.

A055

OFFICE

A006A

OFFICE

A051A

RADIOPHARMACEUTICAL

SCIENCES

RSCH.

A016

937/10

28.2"

46"

STAIR #1

850/16

15.9"

46"

937/10

28.2"

46"

STAIR #4

STAIR #5

MEN'S SHWR

A063D

MAKE-UP

A063H

LS001.1

"A

LS001.2

"B

937/10

18.8"

69"

937/10

18.8"

46.5"

OPEN TO

BOILER RM

BELOW

STAIR #9 EXITS

THIS LEVEL

STAIR #5 EXITS

THIS LEVEL

COMPLIANCE NOTE PER NFPA

7.7.2

STAIR #1 SHALL BE

PERMITTED TO

DISCHARGE THROUGH

AREA OF LEVEL OF EXIT

DISCHARGE.

937/10

18.8"

69"

937/10

18.8"

61"

EXIT

NOT

AN

EXIT

TD = 188'-8"

TD = 118'-6"

TD = 179'-6"

LS

001.2 "B"

LS

001.5 "E"

L S

.3

C

L S

.2

B

247/2

24.8"

80"

STAIR #9

TOTAL OCCUPANTS EXIT THIS

AREA + 1/2 FROM LAB AREA

ELEV.

BLDG. 22

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

WALL

RATING

NEW

PARTITION KEY NFPA 101-2018

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER

2 HR

90 MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

2 HR

90 MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER

2 HR

90 MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)

(1/2 HR = EXIST. ENCL. IN EXIST BLD'G)

1 HR

2 HR

60 MIN

90 MIN

HAZ./INCIDENTAL USE

FIRE BARRIER

1 HR 45 MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS

(SPRINKLERED)

NR-

RESIST

SMK

NR

SELF OR AUTO

CLOSING

SUBDIVIDING SPACES

SMOKE BARRIER (I-2 OCCUPANCY)

20 MIN

1/2

HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

NR

*NR

SELF OR AUTO

CLOSING

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

NR

1 HR

VERT. OPG. (SHAFT)

FIRE BARRIER 60 MIN

1 HR

2 HR

60 MIN

90 MINEXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

6.1.14.4.1 19.1.3.5.1

7.2.4.1.3 (1) 19.1.3.8 19.2.2.5 7.1.3.2.1

19.3.1.1-8 8.6

8.7.1 19.3.2.1

8.5

8.4.2 19.2.5.7.1.4

8.4.2 19.3.6.2

21.3.6 35.3.6

19.3.1

7.2.6

8.2.1.3

8.6

19.2.2.7

8.6

19.3.2.1.2

19.3.7.3

7.2.1.4.1 7.2.4.3.7 8.3.4 19.2.2.5, 1-4

8.3.3.2.2 TBL

19.2.2.2

7.1.3.2 (9)

8.3.3.2.2 TBL

19.3.2.1.3

8.3.3.2.2 TBL

8.5.4 19.3.7.8

8.3.3.2.2 TBL

19.2.2.2.

8.3.3.2.2 TBL

8.3.3.2.2 TBL

8.3.3.2.2. TBL

8.7.1.3 8.4.3 19.3.2.1.3

19.3.6.3.2 8.4.3

19.3.6.3 8.4.3

N/A

FIRE

90 MIN

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR

ONLY

N/A

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLOWED

8.3.4.8 9.2.1

8.3.4.8 9.2.1

8.3.4.8 9.2.1 7.2.4.3.5

N/A

8.5.5.3 19.3.7.3(2)

8.6.4.5

N/A

N/A

8.4.4

8.4.4 8.4.6.2

8.4.4.1 8.4.6.2 19.3.6.4.2

N/A

BASEMENT KEY PLAN

B

SYMBOLS

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

OCC. LOAD

FACTOR

FIRE ALARM CONTROL PANEL

FIRE SYSTEM ANNUNCIATOR ALARM

ANNUNCIATOR PANEL

FACP

FSA

FAA

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

ACTUAL EXIT

WIDTH

NO. OF OCC./

NO. OF EXITS

1:50

10/1

2"

34"

FEC

FP

PROPERTY LINE

STARTING

LOCATION

TRAVEL DISTANCE

TRAVEL PATH

FE

FIRE EXTINGUISHER CABINET

FIRE PULL STATION

FIRE EXTINGUISHER

NOTES

[A] DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS OF

SMOKE BARRIERS WHERE HVAC SYSTEMS ARE FULLY DUCTED

(18.3.7.3x2)

[B] AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL

HAVE DAMPERS (NFPA 8.2.4.4.3) (IBC 710.7)

[C] SMOKE DAMPERS ARE NOT REQUIRED WHERE OPENINGS IN

DUCT ARE LIMITED TO A SINGLE SMOKE COMPARTMENT &

DUCTS ARE MADE OF STEEL (IBC 716.5.5)

[D] TRANSFER GRILLES REGARDLESS OF WHETHER THEY ARE

PROTECTED

ARE NOT ALLOWED IN THESE DOORS OR WALLS (NFPA 18.3.6.4)

TD = XX

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

LS001.2

CODE PLAN - BASEMENT AREA B

CORRECT FIRE & LIFE

SAFETY DEFICIENCIES -

LIFE SAFETY PLANS

800 HOSPITAL DRIVE COLUMBIA, MO 65201

01-31-2020

589A4-19-104

100% CONSTRUCTION DOCUMENTS

3/32" = 1'-0"

0 - BASEMENT - AREA B

HAZARDOUS AREAS IN FULLY

SPRINKLERED BUILDINGS ARE

NOT REQUIRED TO BE

PROTECTED BY FIRE BARRIERS.

COMPLIANCE NOTE

PER NFPA

3.9.3.2.1 &

8.7.1.1 (2)

BLDG. 1 - OCCUPANCY 3

BASEMENT = 158,877 S.F.

OCCUPANCY TYPE - BUSINESS

TYPE II (222) CONSTRUCTION

TOTAL OCCUPANTS 1060

FULLY SPRINKLERED

BUSINESS OCCUPANCY

OCCUPANCY LOAD FACTOR 150

158,877 / 150 = 1060 OCC.

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

JT

FEC

FEC

FEC

F E

C

FEC

F E

C

FE

FE

F E

FE

F E

JT

JT

JT

JT

JT

GLASS WASH

B051

PHARMACOLOGY

RSCH.

B048

PHARMACOLOGY

RSCH.

B042

OFFICE

B049

RSCH.

COMMON RM.

B045

OFFICE

B017

RSCH.

INVESTIGATOR

B022

RSCH.

INVESTIGATOR

B015

CORR.

CBA14

CORR.

CBA1

CHIEF

B006A

ASSOC.

CHIEF

B006B

RSCH.

INVESTIGATOR

B012

OFFICE

B010

ELEC.

CLOSET

B009A

ELEC.

CLOSET

B009B

LACTATION

B009

CLASSROOM

B007ON-CALL

ROOMS/LOUNGE

B011

OFFICE

B010A

OFFICE

B016

AUTOPSY

D031

Room

CBD4

COLD RM.

D030

OFFICE

D024

TLT.

D019C

HAC

C009H

MOW OFFICE

C009I

MOW OFFICE

C009K

FOOD STG.

C009GCORR.

C009J

BIOMEDICAL

ENG.

C002

FOOD PREP

C009

REF.

C009D

JAN.

B002E

OFFICE

B002F

MECH.

C012

FOOD PREP./

COOK

B001B

CART CLEAN

B001C

CHIEF OF

SERVICE

C001A

TLT

B011H

DIETETICS

STG.

B002G

TRNG/BRK.

RM.

B002D

DIETETICS

OFFICE

B002A

RSCH. CORE

AREA

B019

CLOSET

B026A

TRANS. RM.

B027A

PULMONARY

RSCH.

B027

OFFICE

B033

STAIR #3

BO36A

ELEC.

CLOSET

B030

CORR.

CBB3

LAB.

B026

LAB.

B023

OPHTHALMOLOGY

RSCH.

B032

COLD RM.

B037A

COLD RM.

B037

STAIR

ACCESS

B036

SIGNAL

PANELS

B033A

JAN.

B034

CORR.

CBB3

PHARMACOLOGY

RSCH.

B039

OFFICE

B039A

HEALTH

PHYSICS LAB.

B050

RSCH.

OFFICE

B046

RSCH.

INVESTIGATOR

B047

OFFICE

B046A

RSCH.

INVESTIGATOR

B021

OFFICE

B006

OFFICE

B006C

CORR.

B020

OFFICE

B014

OFFICE

B018

OPHTHALMOLOGY

B031

OFFICE

B025B

RHEUMATOLOGY

RSCH.

B024

HAS

B013

CORR.

CBB1

ON-CALL RM.

#1

B011A

TLT

B011B

ON-CALL RM.

#2

B011C

ON-CALL RM.

#3

B011D

TLT

B011E

ON-CALL RM.

#4

B011F

ON-CALL RM.

#5

B001G

ELEC. ROOM

B011J

ON-CALL

ROOMS/LOUNGE

B011

CLEANING

AREA

B001A

VTS/TRVL

SUPERVISOR

B013A

ELEV.

#12

CORR.

CBG3

OFFICE

B001F

DISH CLEAN

B002

DISH CLEAN

B002K

CLOSET

B001E

DIETETICS

OFFICE

C009A

REF.

C009B

OFFICE

C009C

FRZ.

C009F

REF.

C009E

MECH. EQUIP.

C010

TLT.

C009M

TLT.

C009N

CORR.

C009J

OFFICE

C008

BIOMEDICAL

SUPV.

C002B

BIOMED

STORAGE

C002A

OI&T

C001

ELEV.

#8

ELEV.

#7

ELEV.

#4

ELEV.

#5

MECH.

CHASE

C001D

CORR.

CBA13

CORR.

CBG5

937/10

28.2"

46"

STAIR #3

KITCHEN

PREP. AREA

B001D

LS

001.4 "D

LS

001.3 "C

LS

001.1 "A"

LS

001.3 "C

EXIT

NOT

AN

EXIT

T D

T D

T D

L S

.3

C

L S

.2

B

TD = 188'-8"

247/2

24.8"

80"

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

WALL

RATING

NEW

PARTITION KEY NFPA 101-2018

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER

2 HR

90 MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

2 HR

90 MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER

2 HR

90 MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)

(1/2 HR = EXIST. ENCL. IN EXIST BLD'G)

1 HR

2 HR

60 MIN

90 MIN

HAZ./INCIDENTAL USE

FIRE BARRIER

1 HR 45 MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS

(SPRINKLERED)

NR-

RESIST

SMK

NR

SELF OR AUTO

CLOSING

SUBDIVIDING SPACES

SMOKE BARRIER (I-2 OCCUPANCY)

20 MIN

1/2

HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

NR

*NR

SELF OR AUTO

CLOSING

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

NR

1 HR

VERT. OPG. (SHAFT)

FIRE BARRIER 60 MIN

1 HR

2 HR

60 MIN

90 MINEXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

6.1.14.4.1 19.1.3.5.1

7.2.4.1.3 (1) 19.1.3.8 19.2.2.5 7.1.3.2.1

19.3.1.1-8 8.6

8.7.1 19.3.2.1

8.5

8.4.2 19.2.5.7.1.4

8.4.2 19.3.6.2

21.3.6 35.3.6

19.3.1

7.2.6

8.2.1.3

8.6

19.2.2.7

8.6

19.3.2.1.2

19.3.7.3

7.2.1.4.1 7.2.4.3.7 8.3.4 19.2.2.5, 1-4

8.3.3.2.2 TBL

19.2.2.2

7.1.3.2 (9)

8.3.3.2.2 TBL

19.3.2.1.3

8.3.3.2.2 TBL

8.5.4 19.3.7.8

8.3.3.2.2 TBL

19.2.2.2.

8.3.3.2.2 TBL

8.3.3.2.2 TBL

8.3.3.2.2. TBL

8.7.1.3 8.4.3 19.3.2.1.3

19.3.6.3.2 8.4.3

19.3.6.3 8.4.3

N/A

FIRE

90 MIN

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR

ONLY

N/A

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLOWED

8.3.4.8 9.2.1

8.3.4.8 9.2.1

8.3.4.8 9.2.1 7.2.4.3.5

N/A

8.5.5.3 19.3.7.3(2)

8.6.4.5

N/A

N/A

8.4.4

8.4.4 8.4.6.2

8.4.4.1 8.4.6.2 19.3.6.4.2

N/A

BASEMENT KEY PLAN

C

SYMBOLS

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

OCC. LOAD

FACTOR

FIRE ALARM CONTROL PANEL

FIRE SYSTEM ANNUNCIATOR ALARM

ANNUNCIATOR PANEL

FACP

FSA

FAA

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

ACTUAL EXIT

WIDTH

NO. OF OCC./

NO. OF EXITS

1:50

10/1

2"

34"

FEC

FP

PROPERTY LINE

STARTING

LOCATION

TRAVEL DISTANCE

TRAVEL PATH

FE

FIRE EXTINGUISHER CABINET

FIRE PULL STATION

FIRE EXTINGUISHER

NOTES

[A] DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS OF

SMOKE BARRIERS WHERE HVAC SYSTEMS ARE FULLY DUCTED

(18.3.7.3x2)

[B] AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL

HAVE DAMPERS (NFPA 8.2.4.4.3) (IBC 710.7)

[C] SMOKE DAMPERS ARE NOT REQUIRED WHERE OPENINGS IN

DUCT ARE LIMITED TO A SINGLE SMOKE COMPARTMENT &

DUCTS ARE MADE OF STEEL (IBC 716.5.5)

[D] TRANSFER GRILLES REGARDLESS OF WHETHER THEY ARE

PROTECTED

ARE NOT ALLOWED IN THESE DOORS OR WALLS (NFPA 18.3.6.4)

TD = XX

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

LS001.3

CODE PLAN - BASEMENT AREA C

CORRECT FIRE & LIFE

SAFETY DEFICIENCIES -

LIFE SAFETY PLANS

800 HOSPITAL DRIVE COLUMBIA, MO 65201

01-31-2020

589A4-19-104

100% CONSTRUCTION DOCUMENTS

3/32" = 1'-0"

0 - BASEMENT - AREA C

HAZARDOUS AREAS IN FULLY

SPRINKLERED BUILDINGS ARE

NOT REQUIRED TO BE

PROTECTED BY FIRE BARRIERS.

COMPLIANCE NOTE

PER NFPA

3.9.3.2.1 &

8.7.1.1 (2)

BLDG. 1 - OCCUPANCY 3

BASEMENT = 158,877 S.F.

OCCUPANCY TYPE - BUSINESS

TYPE II (222) CONSTRUCTION

TOTAL OCCUPANTS 1060

FULLY SPRINKLERED

BUSINESS OCCUPANCY

OCCUPANCY LOAD FACTOR 150

158,877 / 150 = 1060 OCC.

FEC

FEC

F E

C

LOGISTICS

OFFICE

W05

ELEC. RM.

G008

OFFICE

G019

ELEV. MACH.

RM.

G004A

EQUIP.

G004

ELEV.

#12

ELEV.

#13

ELEV.

#14

ELEV.

CONTROL

G015

CORR.

CBG6

CART WASH

G035

DIRTY

PROCESSING

G032

EQUIP.

G052B

ELEV.

CONTROL

G016

OFFICE &

SUPPLY

G051

STERILIZER

ACCESS

ROOM

G052C

ETO

STERILIZER

ACCESS

G045

STERILIZER

ACCESS

G043A

HALL

G046

ELEC. ROOM

G013

CORR.

CBG2

OFFICE

G019A

STG

G019B

OFFICE

G019C

SHOWER

G040A

CONTROL

ROOM

G042

HALL

G037

HALL

G023

HALL

CBG4

CONFERENCE

R00M

G017

WOMEN'S

LOCKER

G024

MEN'S

LOCKER

G027

MEN'S

SHOWER

G027A WOMEN'S

SHWR

G024B

STORAGE

G029

STORAGE

G030

CORR.

CBG3

WAREHOUSE

BREAKOUT

AREA

W03

WAREHOUSE

W07

TOILET

W08

LOGISTICS

MANAGER

W09

CLOSET

W05B

SHIPPING

AND

RECEIVING

W02

PHARMACY

DRUG CACHE

W03A

CORR.

W03B

BREAK ROOM

G018

WOMEN'S TLT

G024A

FILTER

EQUIPMENT

G052A

VESTIBULE

G031

ANTE ROOM

G059

CORR.

G055

STAIR #12

G060

ELEV. LOBBY

G026MANUAL

WASH RM.

G032A

C/S WORK

AREA

G052

ENDOSCOPE

PROCESS.

G036

ELEV.

#15

STORAGE

G050

CLEAN

RECEIVING

BREAKOUT

G048

BULK STORE

RM

G047

CLEAN

PROCESSING

G043

MECH. RM.

G001

CORR.

G012

LOCKERS

G038

SHOWER

G038A

LOCKERS

G040

WAREHOUSE

W04A

WAREHOUSE

W04

WAREHOUSE

W05A

CANTEEN

STOCKROOM

W06

PROCESS

STORES

W01

L S

.5

E

L S

.4

D

EXIT

BLDG 1 -

OCC. 3

BLDG 2 -

OCC. 4

937/10

18.6"

34.5"

29/2

3"

73"

TD = 141'-0"

T D

T D

TD = 147'-5"

471/13

10.8

42.5"

BASEMENT NOTE

MAXIMUM TRAVEL

DISTANCE TO EXIT = 300'-0"

IN BUSINESS OCCUPANCY

AREAS

(IF SPRINKLERED)

TD = 165'-6

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

WALL

RATING

NEW

PARTITION KEY NFPA 101-2018

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER

2 HR

90 MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

2 HR

90 MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER

2 HR

90 MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)

(1/2 HR = EXIST. ENCL. IN EXIST BLD'G)

1 HR

2 HR

60 MIN

90 MIN

HAZ./INCIDENTAL USE

FIRE BARRIER

1 HR 45 MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS

(SPRINKLERED)

NR-

RESIST

SMK

NR

SELF OR AUTO

CLOSING

SUBDIVIDING SPACES

SMOKE BARRIER (I-2 OCCUPANCY)

20 MIN

1/2

HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

NR

*NR

SELF OR AUTO

CLOSING

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

NR

1 HR

VERT. OPG. (SHAFT)

FIRE BARRIER 60 MIN

1 HR

2 HR

60 MIN

90 MINEXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

6.1.14.4.1 19.1.3.5.1

7.2.4.1.3 (1) 19.1.3.8 19.2.2.5 7.1.3.2.1

19.3.1.1-8 8.6

8.7.1 19.3.2.1

8.5

8.4.2 19.2.5.7.1.4

8.4.2 19.3.6.2

21.3.6 35.3.6

19.3.1

7.2.6

8.2.1.3

8.6

19.2.2.7

8.6

19.3.2.1.2

19.3.7.3

7.2.1.4.1 7.2.4.3.7 8.3.4 19.2.2.5, 1-4

8.3.3.2.2 TBL

19.2.2.2

7.1.3.2 (9)

8.3.3.2.2 TBL

19.3.2.1.3

8.3.3.2.2 TBL

8.5.4 19.3.7.8

8.3.3.2.2 TBL

19.2.2.2.

8.3.3.2.2 TBL

8.3.3.2.2 TBL

8.3.3.2.2. TBL

8.7.1.3 8.4.3 19.3.2.1.3

19.3.6.3.2 8.4.3

19.3.6.3 8.4.3

N/A

FIRE

90 MIN

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR

ONLY

N/A

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLOWED

8.3.4.8 9.2.1

8.3.4.8 9.2.1

8.3.4.8 9.2.1 7.2.4.3.5

N/A

8.5.5.3 19.3.7.3(2)

8.6.4.5

N/A

N/A

8.4.4

8.4.4 8.4.6.2

8.4.4.1 8.4.6.2 19.3.6.4.2

N/A

BASEMENT KEY PLAN

D

SYMBOLS

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

OCC. LOAD

FACTOR

FIRE ALARM CONTROL PANEL

FIRE SYSTEM ANNUNCIATOR ALARM

ANNUNCIATOR PANEL

FACP

FSA

FAA

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

ACTUAL EXIT

WIDTH

NO. OF OCC./

NO. OF EXITS

1:50

10/1

2"

34"

FEC

FP

PROPERTY LINE

STARTING

LOCATION

TRAVEL DISTANCE

TRAVEL PATH

FE

FIRE EXTINGUISHER CABINET

FIRE PULL STATION

FIRE EXTINGUISHER

NOTES

[A] DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS OF

SMOKE BARRIERS WHERE HVAC SYSTEMS ARE FULLY DUCTED

(18.3.7.3x2)

[B] AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL

HAVE DAMPERS (NFPA 8.2.4.4.3) (IBC 710.7)

[C] SMOKE DAMPERS ARE NOT REQUIRED WHERE OPENINGS IN

DUCT ARE LIMITED TO A SINGLE SMOKE COMPARTMENT &

DUCTS ARE MADE OF STEEL (IBC 716.5.5)

[D] TRANSFER GRILLES REGARDLESS OF WHETHER THEY ARE

PROTECTED

ARE NOT ALLOWED IN THESE DOORS OR WALLS (NFPA 18.3.6.4)

TD = XX

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

LS001.4

CODE PLAN - BASEMENT AREA D

CORRECT FIRE & LIFE

SAFETY DEFICIENCIES -

LIFE SAFETY PLANS

800 HOSPITAL DRIVE COLUMBIA, MO 65201

01-31-2020

589A4-19-104

100% CONSTRUCTION DOCUMENTS

3/32" = 1'-0"

0 - BASEMENT - AREA D

HAZARDOUS AREAS IN FULLY

SPRINKLERED BUILDINGS ARE

NOT REQUIRED TO BE

PROTECTED BY FIRE BARRIERS.

COMPLIANCE NOTE

PER NFPA

3.9.3.2.1 &

8.7.1.1 (2)

BLDG. 1 - OCCUPANCY 3

BASEMENT = 158,877 S.F.

OCCUPANCY TYPE - BUSINESS

TYPE II (222) CONSTRUCTION

TOTAL OCCUPANTS 1060

FULLY SPRINKLERED

BUSINESS OCCUPANCY

OCCUPANCY LOAD FACTOR 150

158,877 / 150 = 1060 OCC.

COMPLIANCE NOTE PER NFPA

7.3.1.2

BLDG. 2 - OCCUPANCY 4

BASEMENT = 14,193 S.F.

OCCUPANCY TYPE - STORAGE

TYPE II (000) CONSTRUCTION

TOTAL OCCUPANTS 29

FULLY SPRINKLERED

STORAGE OCCUPANCY

OCCUPANCY LOAD FACTOR N/A

(USED OCC. GROSS / 500)

14,193 / 500 = 29 OCC.

JT

FEC

F E

C

FEC

F E

C

FEC

FE

F E

FIRE SPKLR.

PUMP RM.

D017

BOILER

D018

A/C SHOP

D019C

E.C.C. OFFICE

D019A

STORAGE

D019B

CONTROL

CTR.

D019D

CORR.

D019

SWITCH

GEAR RM.

D020

OFFICE

D024

TLT.

D019C

ST. LNGE.

C003A

OFFICE

C003B

TECH.

SUPERVISOR

OFFICE

C003C

TRANSFORMER

RM.

D…