Drawings_C26863039.pdf
PDF 6 MB Posted
- Solicitation number
- 0000041004
- Issued by
- Sacramento County, California
About this file
This document is a comprehensive set of construction drawings for the Brannan Island Marina Restoration project, prepared by the California Department of Parks and Recreation, Facilities and Development Division, in coordination with the design firm Moffatt & Nichol. The project involves the restoration and modernization of marina facilities at Brannan Island State Park located at 17645 CA-160, Rio Vista, California. Major work components include demolition of existing docks and timber piles; furnishing and installation of a new aluminum dock system with steel pipe guide piles; installation of a security gate and security camera; reuse of the existing gangway and ramp landing structure; dredging and storage of dredged material to a minimum depth of -6.0 feet MLLW with potential overdredging to -8.0 feet; installation of replacement LED luminaire and fire standpipe system; and parking lot and pathway improvements. The project encompasses approximately 243,000 square feet of total area, with the new marina dock occupying 5,610 square feet. The dredging plan identifies quantities of 3,550 cubic yards for primary dredging, 1,850 cubic yards for side slope sloughing, and 2,900 cubic yards of potential overdredging. The facility will include 29 total boat slips with 2 accessible slips per code requirements and will be classified as occupancy type U construction with type V-B construction classification.
The project must comply with the 2025 California Building Code, 2025 California Fire Code, 2025 California Electrical Code, 2005 California Division of Boating and Waterways Layout and Design Guidelines, and NFPA standards including NFPA 14 and NFPA 303 for fire protection in marinas. The fire protection system consists of a Class I Manual Dry Standpipe Hose Connection System with 2.5-inch hose connections spaced to ensure every portion of the float is within 150 feet of a connection. The system must be capable of supplying 500 GPM to the hydraulically most remote standpipe connection and 250 GPM for each additional standpipe. All materials, including piping and components, must be new and rated for minimum 200 PSI working pressure, with plastic piping limited to non-exposed areas and stainless steel piping used in exposed fire protection applications. The completed fire water system must pass hydrostatic testing at 200 PSI for 2 hours with no pressure reduction. The contractor must hold a California State Contractors License Board Type C-16 license for fire protection installation, and all shop drawings must be stamped by a licensed C-16 contractor and approved by the Authority Having Jurisdiction prior to installation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid_Forms_C26863039.pdf | ||
| Project_Manual_C26863039.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
G -1
.d w g D at e:
N ov em be r 1
1:
p m
V1
CALIFORNIA DEPARTMENT OF PARKS AND RECREATION
FACILITIES AND DEVELOPMENT DIVISION
SITE ADDRESS
SCOPE OF WORK
PREPARED BY
STATE OF CALIFORNIA
DEPARTMENT OF PARKS AND RECREATION
FACILITIES AND DEVELOPMENT DIVISION
NORTHERN SERVICE CENTER
2241 HARVARD ST, SUITE 200
SACRAMENTO, CA 95815
BRANNAN ISLAND STATE PARK
BRANNAN ISLAND MARINA RESTORATION
SFM PERMIT NUMBER 26-N-4392-CP
THE MAJOR COMPONENTS OF THE BRANNAN ISLAND MARINA RESTORATION ARE TO: DEMOLISH
EXISTING DOCKS AND PILES, FURNISH AND INSTALL A NEW DOCK SYSTEM AND GUIDE PILES,
FURNISH AND INSTALL A SECURITY GATE, REUSE THE EXISTING GANGWAY AND RAMP LANDING
STRUCTURE, DREDGE AND STORE DREDGED MATERIAL, INSTALL A SECURITY CAMERA, FURNISH
AND INSTALL AN LED LUMINAIRE FURNISH, AND INSTALL A FIRE STANDPIPE SYSTEM.
MOFFATT & NICHOL
2185 NORTH CALIFORNIA BLVD, SUITE 500
WALNUT CREEK, CA 94596
BRANNAN ISLAND STATE PARK
17645 CA-160
Rio Vista, CA 94571
VICINITY MAP
LOCATION MAP
G-1
TI
TL
E S
H E
E T
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
SHEET INDEX
INDEX NO. DRAWING
NO. SHEET NAME
1 G-1 TITLE SHEET
2 G-2 GENERAL NOTES, ABBREVIATIONS, LEGEND, CROSS
REFERENCE AND DATUMS
3 G-3 SITE PHOTOS
4 G-4 EXISTING SITE PLAN
5 G-5 SEDIMENT STORAGE & STAGING SITE PLAN
6 C-1 PROJECT SITE PLAN
7 C-2 DEMOLITION PLAN
8 C-3 DREDGING PLAN - EXISTING BATHYMETRY
9 C-4 DOCK AND PILE PLAN
10 C-5 DOCK AND PILE SECTIONS AND DETAILS
11 C-6 GANGWAY, RAMP LANDING SECTION AND DETAILS
12 C-7 SECURITY GATE - ABUTMENT SECTIONS AND DETAILS
13 C-8 SEDIMENT STORAGE SITE DETAILS
14 C-9 SECURITY CAMERA AND LUMINAIRE DETAILS
15 C-10 PARKING LOT DETAILS
16 C-11 PATH REPAVING
17 M-1 MECHANICAL GENERAL NOTES AND ABBREVIATIONS
18 M-2 FIRE PROTECTION SITE PLAN
19 M-3 DOCK FIRE WATER PLAN
20 M-4 FIRE PROTECTION ELEVATIONS
21 M-5 FIRE PROTECTION DETAILS
22 M-6 FIREWATER PROFILE
CODES AND GUIDELINES
ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF THE FOLLOWING LISTED CODES &
STANDARDS, AND ALL OTHERS HAVING JURISDICTION OVER THE WORK.
· 2025 CA BUILDLING CODE (CBC) TITLE 24, PART 2.
· 2005 CA DIVISION OF BOATING AND WATERWAYS LAYOUT AND DESIGN GUIDELINES FOR
MARINA BERTHING FACILITIES.
· 2025 CA ELECTRICAL CODE (CEC) TITLE 24, PART 3.
· 2025 CA FIRE CODE (CFC) TITLE 24, PART 9.
· 2026 NFPA 303, FIRE PROTECTION STANDARD FOR MARINAS AND BOATYARDS.
BUILDING CODE ANALYSIS (CSFM LIST) MARINA DOCK
1 OCCUPANCY CLASSIFICATION U
2 BUILDING CONSTRUCTION TYPE V-B
3 NUMBER OF STORIES N/A
4 ACTUAL BUILDING HEIGHT N/A
5 BUILDING AREA IN SQUARE FEET 5,610 SF
6 AREA OF PROJECT IN SQUARE FEET 243,000 SF
7 SEPARATED OR NON-SEPARATED USE N/A
8 ALLOWABLE AREA PER CBC N/A
9 AREA INCREASE N/A
10 HEIGHT INCREASE N/A
FIRE SPRINKLERS
TYPE: (WET, DRY, PRE-ACTION OR DELUGE) N/A
FIRE ALARM
TYPE: (MANUAL, AUTOMATIC, ETC) N/A
13 OTHER FIRE PROTECTION SYSTEMS, IF ANY
CLASS I MANUAL DRY
STANDPIPE HOSE
CONNECTION SYSTEM
(NFPA 14 & 303)
14 SMOKE CONTROL SYSTEM N/A
15 OCCUPANT LOAD FOR ENTIRE BUILDING AND
EACH FLOOR N/A
16 YEAR BUILDING WAS CONSTRUCTED NEW BUILD
17 IN A HIGH FIRE HAZARD SEVERITY ZONE? NO
18 SEISMIC JOINTS N/A
EMERGENCY RESPONDER RADIO COVERAGE
(YES OR NO) N/A
20 HIGH-RISE (YES OR NO) N/A
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
G -2
.d w g D at e:
N ov em be r 1
1:
p m
V1
CROSS-REFERENCE LEGEND
NOTE: LETTER INDICATES SECTION; NUMBER INDICATES PLAN,
ELEVATION, OR DETAIL. WHERE THERE IS NO
REFERENCE SHEET INDICATED, IT MEANS THE DETAIL OR
SECTION IS TAKEN AND SHOWN ON THE SAME SHEET.
CXX
SAMPLE VIEW TITLE
SCALE: XX"=XX'
A
CXX
VIEW NUMBER
SHEET NUMBER VIEW
REFERENCED FROM
VIEW TITLE
SECTION CALLOUT
VIEW NUMBER
SHEET NUMBER VIEW
REFERENCED TO
DETAIL CALLOUT
VIEW NUMBER
SHEET NUMBER VIEW
REFERENCED TO
KEYED NOTE
CXX
AB AGGREGATE BASE
AC ASPHALT CONCRETE
ACC ACCESSIBLE
APPROX APPROXIMATELY
CA CALIFORNIA
CBC CALIFORNIA BUILDING CODE
CL CENTERLINE
CLR CLEAR
CONC CONCRETE
DHW DESIGN HIGH WATER
DIA DIAMETER
DLW DESIGN LOW WATER
DR DIMENSION RATIO
(E) EXISTING
EG EXISTING GRADE
EL ELEVATION
EQ EQUAL
EW EACH WAY
F&I FURNISH AND INSTALL
FB FREEBOARD
FDC FIRE DEPARTMENT CONNECTION
FEC FIRE EXTINGUISHER CABINET
FT FEET
H HORIZONTAL
HDPE HIGH-DENSITY POLYETHYLENE
MAX MAXIMUM
MHHW MEAN HIGHER HIGH WATER
MHW MEAN HIGH WATER
MIN MINIMUM
MLLW MEAN LOWER LOW WATER
MLW MEAN LOWER WATER
MSL MEAN SEA LEVEL
NAD83 NORTH AMERICAN DATUM 1983
NAVD88 NORTH AMERICAN VERTICAL DATUM 1988
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NOAA NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION
NTS NOT TO SCALE
OC ON CENTER
POT. PATH OF TRAVEL
R RADIUS
SAP SEDIMENTARY ANALYSIS PLAN
SF SQUARE FEET
SLR SEA LEVEL RISE
SQ SQUARE
SS 316 STAINLESS STEEL
TOT TOTAL
TYP TYPICAL
UHMW ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE
UON UNLESS OTHERWISE NOTED
V VERTICAL
ABBREVIATIONS
G-2
G E
N E
R A
L N
O
TE
S , A
B B
R E
V
IA
TI
O
N S
LE
G E
N D
, C R
O S
S R
E
FE
R E
N C
E A
N D
D A
TU
M
S
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
GENERAL NOTES VERTICAL DATUM
1. PROJECT ELEVATIONS ARE BASED ON MLLW.
2. THE ESTIMATED TIDAL DATUMS AT BRANNAN ISLAND STATE PARK ARE AS FOLLOWS:
3. THE ASTRONOMICAL TIDE DATA IS FROM NOAA (2022), STATION 9415193 - THREEMILE
SLOUGH, SAN JOAQUIN, CA. INFORMATION ON THE 200-YEAR FLOOD IS DETERMINED
FROM THE FLOOD EMERGENCY RESPONSE INFORMATION EXCHANGE (FERIX).
TIDAL DATUM
WATER ELEVATION
(FT, MLLW)
DESIGN HIGH WATER (DHW) (200-YEAR FLOOD) 8.00
HIGHEST ASTRONOMICAL TIDE (HAT) 4.34
MEAN HIGHER HIGH WATER (MHHW) 3.42
MEAN HIGH WATER (MHW) 2.94
MEAN SEA LEVEL (MSL) 1.76
MEAN LOW WATER (MLW) 0.52
MEAN LOWER LOW WATER (MLLW) 0.00
LOWEST ASTRONOMICAL TIDE (LAT) / DESIGN LOW WATER (DLW) -0.97
NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) -1.80
1. ALL MATERIALS SHOWN OR NOTED ON THE PLANS ARE NEW UNLESS NOTED OTHERWISE.
2. THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS SHOWN OR
DIMENSIONED HERE. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
STATE REPRESENTATIVE FOR RESOLUTION BEFORE PROCEEDING WITH THAT PORTION OF THE
WORK.
3. CONDUCT ALL WORK IN ACCORDANCE WITH THE LATEST SAFETY RULES AND REGULATIONS OF
ALL AUTHORITIES AND AGENCIES HAVING JURISDICTION OVER THE WORK.
4. ALL WORK SHALL BE IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS. WHERE
DETAILED INFORMATION OR CLARIFICATION IS REQUIRED, THE MATTER SHALL BE REFERRED TO
THE STATE REPRESENTATIVE FOR WRITTEN RESOLUTION.
5. THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS, BUT SHALL RELY ONLY ON THE WRITTEN DIMENSIONS. IF A DISCREPANCY OCCURS OR NO DIMENSION IS GIVEN, THE CONTRACTOR SHALL
NOTIFY THE STATE REPRESENTATIVE FOR WRITTEN CLARIFICATION BEFORE PROCEEDING WITH
THAT PORTION OF THE WORK.
6. THE OFFICIAL CONTRACT DRAWINGS ARE 24" X 36". SCALES LISTED ARE APPLICABLE TO THAT
SIZE AND MUST BE ADJUSTED ACCORDINGLY WHERE REDUCED SIZE DRAWINGS ARE
REFERENCED.
7. ABSENCE OF A SPECIFICATION SECTION FOR AN ITEM SHOWN ON THE DRAWINGS DOES NOT
RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE SUCH ITEM.
8. DEMOLITION OF EXISTING FEATURES SHALL BE LIMITED TO THE ITEMS SHOWN ON THE PLANS AND DESCRIBED IN THE SPECIFICATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
REPAIR AND/OR REPLACE EXISTING FEATURES TO REMAIN THAT ARE DAMAGED BY THE
CONTRACTOR.
9. PROVIDE CONSTRUCTION SITE SECURITY FOR THE DURATION OF THE CONTRACT PERIOD AND
AS SPECIFIED.
10. FURNISH, INSTALL AND MAINTAIN ALL WARNING SIGNS AND DEVICES NECESSARY TO
SAFEGUARD THE GENERAL PUBLIC AND THE WORK, AND PROVIDE PROPER AND SAFE ROUTING
OF MARINE, VEHICULAR, AND PEDESTRIAN TRAFFIC DURING THE PERFORMANCE OF THE WORK.
THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND SHALL NOT BE LIMITED TO WORKING
HOURS.
11. KEEP THE PROJECT SITE IN A NEAT AND ORDERLY CONDITION, FREE OF RUBBISH AND DEBRIS, AT ALL TIMES.
12. REPRESENTATIVES OF CALIFORNIA STATE PARKS SHALL BE ALLOWED ACCESS DURING
CONSTRUCTION WORK.
13. PROJECT CONTROL:
· HORIZONTAL: NAD83 ZONE 2
· VERTICAL: MLLW
CONCRETE ANCHORS AND THREADED RODS
1. CONCRETE ANCHORS AND THREADED RODS SHALL BE 316 STAINLESS STEEL. ALL NUTS AND
WASHERS SHOULD ALSO BE 316 STAINLESS STEEL.
2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
3. THE CONCRETE ANCHOR SHALL BE STAINLESS-STEEL TITEN HD BY SIMPSON STRONG-TIE, OR
APPROVED EQUAL.
EPOXY GROUT
1. EPOXY GROUT FOR THREADED ANCHOR RODS SHALL BE INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS.
ABUTMENT TIMBER
1. TIMBER DECKING FOR THE ABUTMENT SHALL BE CONSTRUCTION HEART REDWOOD.
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
G -3
.d w g D at e:
N ov em be r 1
1:
p m
V1
G-3
S
IT
E P
H O
TO
S
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
BOAT LAUNCH RAMP
234 5
SITE PHOTOS INDEX
SCALE: NTS
PHOTO 1 - DOCK DAMAGE
SCALE: NTS
PHOTO 2 - ENTRY CHANNEL
SCALE: NTS
PHOTO 3 - FINGER DOCKS
SCALE: NTS
PHOTO 4 - RAMP LANDING
SCALE: NTS
PHOTO 5 - OVERGROWTH
SCALE: NTS
PHOTO 6 - OVERGROWTH
SCALE: NTS
PHOTO 7 - GANGWAYABUTMENT
SCALE: NTS
PHOTO 8 - OVERVIEW
SCALE: NTS 3
MARINA
X
X
X X
X X
X X
X X
X X
X
X
X
X
X
X
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
G -4
.d w g D at e:
N ov em be r 1
1:
p m
V1
G-4
E X
IS
TI
N G
S
IT
E P
LA
N
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
PATH, TYP
BUILDING
TIMBER GUIDE PILE, TYP
GANGWAY
GLULAM DOCKS, TYP
TOP OF BANK
TOP OF BANK
TOE
RETAINING WALL
WIRE FENCE
CURB, TYP
NOTES
1. ALL FEATURES SHOWN ARE EXISTING UON.
2. FEATURES SHOWN BASED ON SURVEY
PERFORMED ON 8/19/2024 BY STEPHEN
GUAY.
MHHW
MLLW
-20' 0' 20' 40'
1" = 20'
LIGHT POLE
TIMBER RETAINING WALL
GANGWAY
ABUTMENT
EXISTING SITE PLAN
SCALE: 1" = 20'
(E) PARKING AREA
RAMP LANDING
ACC
PARKING
STRIPING FOR
PARKING, TYP
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
G -5
.d w g D at e:
N ov em be r 1
1:
p m
V1
G-5
S E
D
IM
E N
T S
TO
R
A G
E
S
TA
G
IN
G S
IT
E
P
LA
N
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
5-100' 0' 100' 200'
1" = 100'
POTENTIAL HAUL
PATH, SEE NOTE 2
DREDGE SEDIMENT STORAGE
APPROX SURFACE AREA OF
175,000 SF, SEE NOTE 1
DREDGE AREA
DREDGE SEDIMENT STORAGE PLAN
SCALE: 1" = 100'
NOTES
1. FINAL SEDIMENT STORAGE AREA TO BE
DETERMINED BY THE STATE'S REPRESENTATIVE.
2. PROTECT PAVEMENT ON HAUL ROUTE WITH
SUFFICIENT MEASURES TO PREVENT DAMAGE.
REPAIR ANY DAMAGES THAT MAY RESULT.
3. CONTRACTOR TO COORDINATE PLACEMENT OF
TEMPORARY ACCESS ROAD WITH THE STATE'S
REPRESENTATIVE. CONTRACTOR TO ANTICIPATE
HAVING TO PLACE AGGREGATE BASE FOR
TEMPORARY ROAD SURFACING TO ACCESS
SEDIMENT STORAGE AREA. TEMPORARY ACCESS
ROAD TO BE REMOVED BY THE CONTRACTOR
WHEN HAULING IS COMPLETE.
4. AVOID DAMAGE OR INTRUSION INTO THE FUTURE
WATER TANK STORAGE AREA.
5. CONTINUOUS ACCESS TO BE MAINTAINED TO THE
RV CAMPSITE CONNECTED TO THE PARKING AREA.
CONTRACTOR EFFORTS SHALL NOT BLOCK THE
ROADWAY FOR VEHICULAR INGRESS AND EGRESS
TO THE RV CAMPSITE.CONTRACTOR
STAGING AREA,
APPROX 25,800 SF
CONTRACTOR
PARKING AREA,
SEE NOTE 5
C-8
FUTURE WATER TANK
STORAGE AREA, SEE NOTE 4
TEMPORARY ACCESS
ROAD, SEE NOTE 3
(E) RV CAMPSITE
X
X X
X X
X X
X X
X X
X
X
X
X
X
X
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -1
.d w g D at e:
N ov em be r 1
1:
p m
V1
C-1
P R
O
JE
C T
S
IT
E P
LA
N
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
(E) PATH, TYP
(E) PARKING AREA
(E) BUILDING
(E) TOP OF BANK
(E) TOP OF BANK
(E) TOE
(E) RETAINING WALL
(E) WIRE FENCE
(E) CURB, TYP
MHHW
MLLW
-20' 0' 20' 40'
1" = 20'
(E) LIGHT
POLE
(E) TIMBER
RETAINING WALL
KEY NOTES
F&I ALUMINUM DOCK SYSTEM, SEE
REUSE GANGWAY AND LANDING RAMP, SEE
F&I STEEL PIPE PILES, SEE
F&I SECURITY GATE, SEE
FURNISH CAMERA ON LIGHT POLE AND F&I LUMINAIRE,
SEE
SEDIMENT REMOVAL, SEE
F&I PARKING IMPROVEMENTS, SEE
F&I REPLACEMENT AC FOR PATHS, SEE
F&I FIRE STANDPIPE SYSTEM, SEE M-SHEETS
PROJECT SITE PLAN
SCALE: 1" = 20'
PROJECT CONTROL
WORK POINT NORTHING EASTING ELEVATION
WP1 1803914.90 6650887.59 18.06
WP2 1803983.18 6650730.66 23.96
WP3 1803853.15 6650672.05 24.69
WP4 1803770.60 6650599.44 25.93
WP5 1803961.82 6650937.56 17.76
WP6 1803758.62 6651016.53 17.83
WP7 1803860.10 6650892.89 11.69
WP8 1803873.84 6650739.40 14.39
WP1
WP2
WP3
WP4
WP5
WP6
WP7
WP8
LEGEND
WORK POINT
FEC
CLEAT
ACC POT.
AC REPLACEMENT
CONC
C-4
C-4
A C-6
A C-7
C-9
C-3
ACC
SLIP
ACC
SLIP
ACC POT.
, TYP3
PARKING
SPACE, TYP
, TYP9
FDC
ACC PARKING
FIRE HYDRANT,
NIC
C-10
C-11
AC WALKWAY
(E) AC WALKWAY
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -2
.d w g D at e:
N ov em be r 1
1:
p m
V1
DEMO (E) TIMBER GUIDE PILE, TYP
SEE NOTE 2
DEMO (E) GLULAM DOCK, TYP
SEE NOTE 3
(E) GANGWAY,
SEE NOTE 1
(E) RAMP LANDING,
SEE NOTE 1
NOTES
1. REMOVE GANGWAY AND RAMP LANDING AND
PROTECT FOR REUSE.
2. PULL THE ENTIRE LENGTH OF THE TIMBER PILE.
IF THE PILE BREAKS WITHOUT FULL
EXTRACTION, CUT PILE 2 FEET BELOW THE
AFTER DREDGE MUDLINE. 10 TOTAL
3. DEMOLISH GLULAM DOCKS - APPROX 6200 SF.
4. THE EXISTING PUMPOUT UNIT HAS A
DISCHARGE PIPELINE AND ELECTRICAL
CONNECTION, IT IS ASSUMED THAT THESE ARE
DISCONNECTED. DEMOLISH ANY UTILITIES
FOUND IN THE BASIN.
MHHW
MLLW
LEGEND
DOCK DEMOLITION
DEMOLITION PLAN
SCALE: 1" = 10'
C-2
D E
M O
LI
TI
O N
P
LA
N
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
10' 0' 10' 20'
SCALE: 1''=10'
DEMO (E) PUMPOUT
SEE NOTE 4
REMOVE (E) TIMBERS
ON THE (E) ABUTMENT
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -3
.d w g D at e:
N ov em be r 1
1:
p m
V1
C-3
D R
E D
G
IN
G P
LA
N
E
X
IS
TI
N
G B
A
TH
Y M
E
TR
Y
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
NOTES
1. EXISTING FEATURES NOT SHOWN IN PLAN VIEW
FOR CLARITY. DOCK SHOWN TO PROVIDE
REFERENCE, PERFORM DREDGE PRIOR TO
DOCK INSTALLATION.
2. DREDGE TO -6' MLLW MIN. ANY AMOUNT
DREDGED PAST THIS DEPTH WILL NOT BE PAID
FOR. DO NOT DREDGE PAST -8' MLLW. THE
LIMITS OF THE DREDGE ARE TO THE TOE OF THE
REVETMENT AND THE -6' CONTOUR ON THE
OUTLET SIDE AS SHOWN.
3. DREDGE SIDE SLOPE MATERIAL THAT SLOUGHS
WITHIN DREDGE BOUNDARY. THE EXTENTS OF
SIDE SLOUGHING SHOWN ARE SCHEMATIC.
4. ENTRANCE CHANNEL BOTTOM WIDTH TO BE 40'
MIN. ADDITIONAL DREDGING OF THE ENTRANCE
CHANNEL BOTTOM WIDTH TO REVETMENT TOE
WILL BE COMPENSATED, IF ORDERED BY THE
STATE REPRESENTATIVE.
5. DO NOT UNDERMINE THE REVETMENT. STOP
WORK SHOULD REVETMENT SLOPE BEGIN TO
FAIL AND NOTIFY THE STATE REPRESENTATIVE.
6. IF ROCK IS ENCOUNTERED WITHIN THE DREDGE
FOOTPRINT, THE CONTRACTOR SHALL NOTIFY
THE STATE REPRESENTATIVE.
7. THE ROCK SLOPE AND EXTENTS ARE ESTIMATED
BASED ON LIMITED SURVEY DATA AND VISUAL
OBSERVATIONS. THE ACTUAL REVETMENT
LAYOUT MAY VARY. THERE ARE NO AVAILABLE
AS-BUILTS.
8. THE PERMITTED DREDGE QUANTITY
REPRESENTS DREDGING FROM THE TOP OF THE
BANK DOWN TO -8' MLLW WITH SIDE SLOPE
SLOUGHING. THIS QUANTITY IS NOT TO BE USED
FOR CONSTRUCTION.
-20' 0' 20' 40'
1" = 20' E
N
TR
A N
C E
C H
A N
N E
L S
E E
N O
TE
APPROX (E) TOE OF
REVETMENT AS
DREDGE BOUNDARY,
SEE NOTE 2
DOCK, TYP
GUIDE PILE, TYP
POTENTIAL SIDE
SLOPE SLOUGHING,
SEE NOTE 3
DHW
EL 8.00'
DLW
EL -0.97'
EG
(E) REVETMENT
TOE OF (E)
REVETMENT
DESIGN MINIMUM DREDGE DEPTH
EL -6.0' MLLW, TYP
DOCK
ENTRANCE CHANNEL
SEE NOTE 4
(E) REVETMENT, TYP
EG, TYP
POTENTIAL SIDE
SLOPE SLOUGHING,
SEE NOTE 3, TYP
DLW
EL -0.97'
0'
-5'
5'
10'
15'
TOE OF (E)
REVETMENT, TYP
-5' 0' 5' 10'
1" = 5'
C-1
DREDGING PLAN
SCALE: 1" = 20'
A
SECTION - SIDE SLOPE
SCALE: 1" = 5'
B
SECTION - ENTRANCE CHANNEL
SCALE: 1" = 5'
A
B
0'
-0
236'-0"
8'-0"
6' -0
6' -0
MAXIMUM DREDGE DEPTH
EL -8.0' MLLW, TYP
DESIGN MINIMUM DREDGE DEPTH
EL -6.0' MLLW, TYP
MAXIMUM DREDGE DEPTH
EL -8.0' MLLW, TYP
LEGEND
POTENTIAL SIDE SLOPE SLOUGHING
REQUIRED DREDGING
APPROX TOE OF
REVETMENT
APPROX TOE OF
REVETMENT, TYP
DREDGE TO -6' MLLW,
SEE NOTE 2 DREDGE
BOUNDARY
LIMIT AT
OUTLET
POTENTIAL SIDE
SLOUGHING, SEE NOTE 3
QUANTITIES
DREDGE TO -6' 3,550 CY
DREDGE OF SIDE SLOPE
SLOUGHING (2H:1V) 1,850 CY
OVERDREDGE FROM -6' TO -8' 2,900 CY
PERMITTED DREDGE
(NOT FOR CONSTRUCTION) 15,200 CY
APPROX TOP OF BANK
PERMITTED DREDGE
BOUNDARY, SEE NOTE 8
PILE COORDINATES
PILE NUMBER NORTHING EASTING
P1 1803706.83 6650950.28
P2 1803759.85 6650907.69
P3 1803798.83 6650876.38
P4 1803837.81 6650845.07
P5 1803862.92 6650810.54
P6 1803829.11 6650768.44
P7 1803791.13 6650721.09
P8 1803756.16 6650743.41
P9 1803717.17 6650774.72
P10 1803678.19 6650806.03
P11 1803625.17 6650848.61
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -4
.d w g D at e:
N ov em be r 1
1:
p m
V1
C-4
D O
C K
A N
D P
IL
E
P
LA
N
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
MHHW
MLLW
C-1
DOCK AND PILE PLAN
SCALE: 1" = 10'
10' 0' 10' 20'
SCALE: 1''=10'
LEGEND
FEC ( TOTAL 7 )
CLEAT24'-0"
TYP
6'-4"
'-0
TY
P
STEEL PIPE PILE, TYP,
SEE NOTE 2
27'-0"
TYP
3'-0"
TYP
31'-0"
'-0
FA
IR
W
A Y
W
ID
TH
12'-0"
6'-0"
8'
-0
24'-0"
'-0
TY
P
9'-8"
6' -0
40'-0"
TYP
50'-0"
TYP
50'-0"
TYP
68'-0"
TYP
6' -0
12'-0"
TYP
220'-0"
ALUMINIUM
FRAMED DOCK, TYP
SECURITY GATE SEE
3'-0"
TYP
'-0
TY
P
'-0
48'-7"±
C-5
A C-5
B C-5
(E) GANGWAY
ABUTMENT
A C-6
NOTES
1. STANDPIPE SYSTEM NOT SHOWN FOR
CLARITY.
2. ADJUST LOCATION OF STEEL PIPE PILES TO
BE A MINIMUM OF 10 FEET AWAY FROM
TIMBER PILE STUBS IF NECESSARY.
A C-7
REINSTALL
GANGWAY AND
RAMP LANDING,
SEE
7' -0
TY
P 8'
-0
TY
P
8' -0
TY
P
1'-0"
TYP
10'-0"
TYP
4'-0"
TYP
7' -0
TY
P
'-0
TY
P
'-0
TY
P
1'-0"
TYP
4'-0"
TYP
11'-6"
TYP
13'-6" 4'-0" 13'-6"
ACC
SLIP
ACC
SLIP
3' -4
'-0
75'-0"
TYP
75'-0"
TYP
29'-0"
TYP
BOAT SLIPS
1. 29 TOTAL BOAT SLIPS IN THE MARINA.
2. PER CBC 11B-235.2, 2 ACCESSIBLE BOAT
SLIPS ARE REQUIRED FOR THIS MARINA.
5'X5'
MANEUVERING
CLEARANCE
4'X4'
MANEUVERING
CLEARANCE
6'-0" CLR
MIN
P1P2P3P4
P5
P6
P7 P8 P9 P10 P11
7' -6
" C
LR
M
IN
C-6
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -5
.d w g D at e:
N ov em be r 1
1:
p m
V1
C-5
D O
C K
A N
D P
IL
E
S E
C
TI
O N
S A
N D
D E
TA
IL
S
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
NOTES
1. LAYOUT AND DIMENSIONS OF FLOATATION UNITS
ARE TO BE DESIGNED BY THE CONTRACTOR TO MEET
LOAD AND FREEBOARD REQUIREMENTS.
2. PILE CAP SHALL HAVE A MINIMUM WALL THICKNESS
OF 1/8". PROVIDE A LAYER OF GEL-COTE
PROTECTION. FASTEN TO THE PILE.
3. UHMW FRAME SHALL BE MONOLITHIC AND CUT TO FIT
THE PILE OPENING AND PILE BASED ON FIELD
CONDITIONS. PROVIDE 1/4" CHAMFER ALONG THE
TOP AND BOTTOM OF UHMW FRAME WHICH
INTERFACES WITH THE PILE SURFACE.
4. SEPARATION TAPE SHALL SEPARATE DISSIMILAR
METALS.
5. ASSUME THAT THE BOTTOM OF THE SAND FILL WILL
BE APPROXIMATELY 12" PAST THE DREDGED
MUDLINE DUE TO SOIL DISPLACEMENT DURING
DRIVING.
2"
WIDTH DIMENSION VARIES
COMPOSITE
LUMBER DECKING
12" CLEAT
1' -6
FB
ALUMINUM
FRAMING
RUB STRIP, ES
FULLY ENCASED
FLOATATION
UNITS, SEE NOTE 1
2"
TYP
WIDTH DIMENSION VARIES
12" CLEAT, ES
DOCK CORNER
BUMPER, ES DECKING
RUB STRIP, ES
ALUMINUM
FRAMING
1' -6
FB
A C-4
SECTION - MAINWALK
SCALE: 1 1/2" = 1'-0"
FULLY ENCASED
FLOATATION
UNITS, SEE NOTE 1
B C-4
SECTION - FINGER DOCK
SCALE: 1 1/2" = 1'-0"
2'-6"
2' -6
INSIDE EDGE OF
UHMW FRAME,
SEE NOTE 3
CL GUIDE PILE =
CL GUIDE PILE
BRACKET
INSIDE EDGE OF
COVER BOARD
POLYMER COVER BOARD
INSIDE EDGE OF L3x3
INCOVER BOARD
FASTENERS, TYP
(TOTAL 12)
DECK
1" ALL AROUND
TYP
1/2" ALL AROUND
TYP
5/8" THICK POLYMER COVER
BOARD ATTACH PILE GUIDE
FRAME WITH SS SCREWS, TYP
1 1/2" THICK UHMW PILE
GUIDE FRAME, TYP
SEE NOTE 3
L3x3x1/4, TYP
BOLT WITH COUNTERBORE
ATTACH UHMW PILE GUIDE
FRAME TO FRAME, TYP
ALUMINUM FRAMING, TYP
DISSIMILAR METALS
SEPARATION TAPE, TYP
SEE NOTE 4
FLUSH
SS FASTENERS SIZE &
SPACING PER DOCK
MANUFACTURER, TYP
STEEL PIPE PILE
TOP OF PILE
EL +13.50'
PILE CAP,
SEE NOTE 2
12" DIA X 3/8" WALL THICKNESS,
STEEL PIPE PILEDREDGED MUDLINE EL
VARIES, -6.00' TO -8.00'
SEE
C
SECTION - STEEL PIPE PILE
SCALE: 1 1/2" = 1'-0"
C
DETAIL
SCALE: 3" = 1'-0"
C-4
PLAN - GUIDE PILE BRACKET
SCALE: 1 1/2" = 1'-0"
0'-6" 0'-0'' 0'-3" 0'-6"
SCALE: 3"=1'-0''
1'-0" 0'-0'' 0'-6" 1'-0"
SCALE: 1 1/2"=1'-0''
RUB STRIP, TYP
PILE TIP
EL -48.00'
TOP OF SAND FILL
EL +9.50'
NOMINAL BOTTOM OF SAND FILL,
SEE NOTE 5
SAND FILL
SAND FILL
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -6
.d w g D at e:
N ov em be r 1
1:
p m
V1
C-6
G A
N G
W A
Y , R
A M
P L
A N
D
IN
G S
E C
TI
O
N A
N D
D E
TA
IL
S
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
NOTES
1. IN THE ELEVATION VIEW, DOCK AND LANDING RAMP
LEGS ARE NOT SHOWN FOR THE HIGHEST
ACCESSIBLE TIDE FOR CLARITY.
(E) ABUTMENT
DECKING OF
(E) GANGWAY
ABUTMENT EL +7.80
(E) 30' GANGWAY
(E) RAMP
LANDING
DOCK
4' -6
HIGHEST ACCESSIBLE TIDE
EL +4.30'
LOWEST ACCESSIBLE TIDE
EL -0.70'
1:12
SLOPE
1:12
SLOPE
SEE , TYP EACH LEG
(E) LANDING
RAMP LEG
(E) PLATE 6x6
DECK BOARD
1/2"Ø x 3" HDG
BOLT WITH NUT &
WASHER, TYP
(E) LANDING
RAMP LEG
(E) PLATE 6x6
1/2"Ø BOLT , TYP
A C-4
ELEVATION - GANGWAY
SCALE: 3/4" = 1'-0"
C-1
DETAIL - LANDING RAMP CONNECTION
SCALE: 6" = 1'-0"
B
SECTION
SCALE: 6" = 1'-0"
B
0'-2" 0'-0'' 0'-2" 0'-4"
SCALE: 6"=1'-0''
2'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 3/4"=1'-0''
116'-0" 0'-0'' 3'-0" 6'-0"
SCALE: 1/4"=1'-0''
4' -0
" C
LR
W
ID
TH
(E) ABUTMENT
'-0
(E
) L O
W E
R L
A N
D
IN
G
4' -0
" C
LR
W
ID
TH
4'-0" CLR
WIDTH
30'-0"
(E) GANGWAY
30'-0"
(E) UPPER RAMP
8'-0"
(E) UPPER LANDING
24'-0"
(E) LOWER RAMP
8'-1"
7' -4
(E
) S
TA
IR
S
4'-0" CLR
WIDTH
4' -0
" C
LR
W
ID
THVARYING
SLOPE
1:12
SLOPE
1:12
SLOPE
FL
A
T S
LO
P
E
FLAT
SLOPE
DOCKS
C-4
DETAIL PLAN - EXISTING GANGWAY AND RAMP
SCALE: 1/4" = 1'-0"
MARINA
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -7
.d w g D at e:
N ov em be r 1
1:
p m
V1
C-7
S E
C U
R
IT
Y G
A
TE
A
B U
TM
E
N T
S E
C
TI
O N
S A
N D
D E
TA
IL
S
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
NOTES
1. VERIFY DIMENSIONS IN FIELD PRIOR TO
FABRICATION. PLACE SECURITY GATE SO THAT THE
EXTENTS ARE FLUSH WITH THE EXISTING ABUTMENT.
2. DECK BOARDS PLACED ON EXISTING ABUTMENT
SHALL BE 6x12 TIMBERS. BOARDS SHALL HAVE A GAP
OF 1/4". CUT BOARDS AS NECESSARY TO FIT AROUND
THE SECURITY GATE OR MOUNT THE GATE ON THE
DECK BOARDS AND ANCHOR TO THE GANGWAY
ABUTMENT.
3. RECESS HEAD OF 3/8" DIAMETER BY 9" LONG
ANCHOR BOLTS IN DECK BOARD SO AS TO NOT
CREATE A TRIPPING HAZARD. INSTALL 4 ANCHORS
ON EACH BOARD WITH 2 ANCHORS ON EITHER END
OF THE BOARD. ADD PLUGS TO SEAL COUNTER-BORE
HOLES.
4. VERIFY THE (E) GANGWAY ATTACHMENT TO THE (E)
ABUTMENT.
5'-0"
'-5
/2
8' -1
4"
6" TY
P
6'-6"
SEE NOTE 1
6"
TYP
1'-2 1/2"1'-1 1/2"
TYP
1'-11"
RECESSED HDPE
SIGN PANEL
SQUARE TUBE
EXPANDED
ALUMINUM
SHEET, TYP
1" INTERMEDIATE
BAR
NUMBER PAD
HANDLE
ANCHOR
BOLT, TYP
FOOTING
PLATE, TYP
GANGWAY ABUTMENT
SURFACE
DECK BOARD,
SEE NOTE 2
6"
4" TY
P
4"
TYP
6"
SQUARE TUBE
INTERMEDIATE BAR, TYP
2'-10 1/2"
4' -0
4"
1 1/2"
TYP
GUARDRAIL
DECK BOARD, TYP
SEE NOTE 2
(E) GANGWAY ABUTMENT
SEE
SEE .
(E) ABUTMENT (E) GANGWAY
2"
TYP
ANCHOR BOLT WITH
RECESSED HEAD, TYP
SEE NOTE 3
DECK BOARD, TYP
SEE NOTE 2
DECK BOARD
SEE NOTE 2
RAIL POST
4" TIMBER LAG
SCREWS, TYP
0'-6" 0'-0'' 0'-3" 0'-6"
SCALE: 3"=1'-0''
1'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 1"=1'-0''
A C-4
ELEVATION - FRONT OF SECURITY GATE
SCALE: 1" = 1'-0"
C-1
B
ELEVATION - SIDE OF SECURITY GATE
SCALE: 1" = 1'-0"
DETAIL - GANGWAY ABUTMENT
SCALE: 1" = 1'-0"
DETAIL - GUARDRAIL CONNECTION
SCALE: 3" = 1'-0"
B
3/8" THREADED ROD @ 12"
GRADE TO MATCH TOP OF
GANGWAY ABUTMENT DECK
MAX SLOPE SHALL BE 1:20
HINGE,
TYP
4"
TYP
(E) GANGWAY
REATTACH
GANGWAY HINGE
EXPANDED
ALUMINUM SHEET
1"
TYP
1'-0 1/2"
TYP BIRD
DETERRENT
SPIKES, TYP
SIDE WALL
SPIKES, TYP
4'-6"
1' -6
1/2" DIA X 12" LONG
ANCHOR BOLT, 2
PER SIDE POST
1/2" DIA X 12" LONG
ANCHOR BOLT, 4 PER
FACE-MOUNTED POST
3/4" DIA THREADED ROD W/
EPOXY GROUT
2'-0" MIN EMBEDMENT
TYP
GANGWAY HINGE
ATTACHMENT FACE
PLATE, SEE NOTE 4
TIMBER BOARD
BEHIND ABUTMENT
3/4" DIA THREADED
ROD, TYP
4"
TYP
EQ EQ
C
GANGWAY PLATE ATTACHMENT
SCALE: 1" = 1'-0"
C
3' -1
"3' -6
3'-0"
DOOR
4"
TYP
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -8
.d w g D at e:
N ov em be r 1
1:
p m
V1
C-8
S E
D
IM
E N
T S
TO
R
A G
E S
IT
E
D E
TA
IL
S
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
131'-0" 0'-0'' 0'-6" 1'-0"
SCALE: 1 1/2"=1'-0''
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
1' -0
" E M
B E
D M
E N
T M
IN
1"X1"X24" STAKE
@ 48" MAX, TYP
2" MIN
4" MAX
8" DIA STRAW WATTLE, TYP
DREDGE MATERIAL
AT STORAGE SITE.
SEE NOTE 1
EG
G-5
DETAIL - SEDIMENT STORAGE SITE EROSION CONTROL
SCALE: 1 1/2" = 1'-0"
NOTES
1. SLOPE DREDGED MATERIAL TO DRAIN. THE HEIGHT
OF THE DREDGED MATERIAL SHALL BE 3 FEET
MAXIMUM ABOVE EG.
1:2
MAX SLOPE
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -9
.d w g D at e:
N ov em be r 1
1:
p m
V1
C-9
S E
C U
R
IT
Y C
A M
E R
A A
N D
L U
M
IN
A
IR
E D
E
TA
IL
S
11-17-2026
J. ESTRADA
PH, EP, JE
R. DORNHELM
140'-6" 0'-0'' 0'-3" 0'-6"
SCALE: 3" = 1'-0''
C-1
CAMERA DETAIL
SCALE: 3" = 1'-0"
REPLACEMENT
LED LUMINAIRE,
SEE NOTE 3
(E) SQUARE STEEL LIGHT POLE, SEE
CAMERA,
SEE NOTE 1 15
'-0
M O
U N
T H
E
IG
H T
POTENTIAL ROUTER
FOR CAMERA
NOTES
1. INSTALL CAMERA TO FACE TOWARDS DOCKS.
2. DIAMETER AND LENGTH OF SELF DRILLING
SCREWS SHALL BE PER THE CAMERA
MANUFACTURER'S RECOMMENDATIONS.
3. DEMOLISH AND DISPOSE OF THE EXISTING
LUMINAIRE ON LIGHT POLE. THE REPLACEMENT
LED LUMINAIRE SHALL BE UBIU-9001-42W AS
SUPPLIED BY LIGMAN LIGHTING, OR APPROVED
EQUAL.
LIGHT POLE PHOTO
SCALE: NTS
EG
SELF DRILLING SS SCREWS WITH
HEX HEAD, SEE NOTE 2
X X
X
XXXXXX
X
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -1
0.
dw g D at e:
N ov em be r 1
1:
p m
10-23-2026
NOTES
1. THE EXTENT OF THE CONCRETE PAD
SHALL INCLUDE THE ACCESSIBLE
PARKING STALL AND ACCESS AISLE
INCLUDING THE STRIPING. DEMOLISH
AND DISPOSE OF THE EXISTING AC, AB,
AND SUBGRADE AS NEEDED TO F&I THE
CONCRETE PAD.
2. SAWCUT 1' FROM THE EDGE OF THE
CONCRETE PAD, PAVE NEW ASPHALT TO
THE EXISTING GRADE SO THAT A SLOPE
OF 2% IS NOT EXCEEDED. THE
INTERFACE BETWEEN THE EXISTING AND
NEW ASPHALT SHALL BE FOG SEALED.
3. FOG SEAL EXISTING STRIPING PRIOR TO
NEW STRIPING.
4. SCARIFY THE NATIVE SUBGRADE 4" IN
DEPTH AND RECOMPACT AT 95%
RELATIVE COMPACTION.
TYPICAL PARKING SPACES
SCALE: NTS
ISA MARKING
(TYP), SEE CSP
A90A
4" BLUE
LINE
BORDERS
SIGN R99C & R7-8B SEE
4" WHITE
LINE, TYP
9'
TYPICAL STANDARD
PARKING SPACE
NO
PARKING
12" HIGH
WHITE
LETTERS
(E) CURB
8'9'
SIGN (R100B) STANDARD
18" X 24"
ACCESSIBLE PARKING ONLY MINIMUM
FINE $250 (R99C)
STANDARD 12" X 24"
12" DIA X 24"
DEEP CONCRETE
FOOTING
5'- 0"
(R
0B
6'- 8"
(R
C W
/ R 7-
8B
2" DIAMETER
GALVANIZED
STEEL PIPE
2-1/2" DIAMETER
GALVANIZED STEEL
PIPE SLEEVE
INSTALL
SIGN(S)
3/8" DIAMETER
BOLT/NUT THROUGH
1/2" DIAMETER DRILLED
HOLE
1- 1/
2"
3" 6"
UNAUTHORIZED VEHICLES PARKED IN
DESIGNATED ACCESSIBLE SPACES NOT
DISPLAYING DISTINGUISHING PLACARDS OR
SPECIAL LICENSE PLATES ISSUED FOR
PERSONS WITH DISABILITIES WILL BE
TOWED AWAY AT OWNER'S EXPENSE
TOWED VEHICLES MAY BE
RECLAIMED BY TELEPHONING
(XXX) XXX-XXXX*
SIGN POST
* INFORMATION TO BE
PROVIDED BY THE OWNER
VAN-ACCESSIBLE PARKING
(R7-8B) 12" X 6"
VAN-ACCESSIBLE
PARKING SPACE
4" WHITE LINE
DIAGONALS, TYP
PARKING SIGNS
SCALE: NTS
SIGN R100B SEE 3
C-10
PA
RK
IN
G
LO
T
DE
TA
IL
S
11-17-2026
J. ESTRADA
JE
R. DORNHELM
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -1
0.
dw g D at e:
N ov em be r 1
1:
p m
V1
(E) CURB, TYP
EDGE OF
PAVEMENT
1'
SAWCUT, SEE NOTE 2
CONC PAD FOR ACC PARKING
STALL AND ACCESS AISLE, SEE
NOTE 1
(E) CURB, TYP
STRIPING FOR
PARKING STALL, TYP
SEE NOTE 3 &
PARKING SIGN(E) LIGHT POLE
(E) FENCE
STRIPING FOR ACC PARKING
STALL AND ACCESS AISLE, TYP
SEE
C-1
DETAIL PLAN - PARKING AREA
SCALE: 1" = 10'
A
(E) AC
#4 @ 12" EW, TYP
6" C
O N
C 6"
A B
FLUSH
A
SECTION - CONCRETE PAVING
SCALE: 3" = 1'-0"
-10' 0' 10' 20'
1" = 10'
0'-6" 0'-0'' 0'-3" 0'-6"
SCALE: 3" = 1'-0''
3'
3' PARTIAL DEMO OF
(E) CURB
PARTIAL (E) CURB DEMO
DEMO (E) ISA SIGN
(E) SIGN
3" A
C 9"
A B
SAWCUT 1'
EL 25.56'
EL 25.31'
EL 25.23'EL 25.45'
SUBGRADE, SEE NOTE 4
LEGEND
AC
AB
CONC
CURB DEMO
ELEVATION POINT
27.43'
26.79'
26.35'
25.18'
24.06'
23.19'
22.49' 21.86' 21.04'
20.80'
20.70'
20.69'
20.84'
20.86'
20.34'
19.87'
19.11' 16.03'
13.10'
11.76'
11.31'
11.68'
-2 .0
-1
.5
-2 .9
-3 .8
-2.
6%
-2.3%
-2.0% -2.0% -0.7%
-0 .3
-0
.0 % 0.3%
0.3%
-3.1%
-2 .7
-4.2%
-4.5%
-4.5%
-4.3%
-2.
9%
1.
2%
X X
X X
X X
X X
X X
X
XX
X
X X
X X
PROJECT CONTROL
WORK POINT NORTHING EASTING
WP9 1803894.23 6650694.58
WP10 1803885.83 6650702.90
WP11 1803930.30 6650736.58
WP12 1803889.63 6650970.51
WP13 1803869.99 6650975.61
WP14 1803894.66 6650798.15
WP15 1803897.16 6650784.64
WP16 1803890.00 6650792.35
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -1
1.
dw g D at e:
N ov em be r 1
1:
p m
10-23-2026
NOTES
1. THE MARINA DOCKS, GANGWAY,
SECURITY GATE, AND LANDING ARE NOT
SHOWN FOR CLARITY.
2. FEATURES SHOWN ON THIS SHEET ARE
BASED ON A SURVEY PERFORMED ON
10/12/2026 BY JAMES DICKEY.
3. PROTECT EXISTING SITE FEATURES NOT
CALLED TO BE DEMOLISHED.
4. DEMOLISH AND DISPOSE OF THE
EXISTING ASPHALT AND AGGREGATE
BASE, ASSUMED TO BE 2" OF AC OVER 1"
OF AB, FOR THE WALKWAY AND REPLACE
WITH THE NEW SECTION. ENSURE THAT
THE MAXIMUM LONGITUDINAL SLOPE IS
4.5%. APPROXIMATELY 5100 SF.
5. LANDINGS SHALL HAVE A MAXIMUM OF
LONGITUDINAL AND CROSS SLOPE OF
1.5%.
6. SCARIFY THE NATIVE SUBGRADE 4" IN
DEPTH AND RECOMPACT AT 95%
RELATIVE COMPACTION.
7. CROSS SLOPE TO SLOPE TOWARDS THE
MARINA BASIN.
8. CLEAR AND GRUB VEGETATION BETWEEN
WALKWAY AND TIMBER RETAINING WALL.
C-11
PA
TH
R
EP
AV
IN
G
11-17-2026
J. ESTRADA
JE
R. DORNHELM
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
C -1
1.
dw g D at e:
N ov em be r 1
1:
p m
V1
(E) CABIN
C-1
REPLACEMENT ASPHALT PLAN
SCALE: 1" = 20'
B
-20' 0' 20' 40'
1" = 20'
1'-0" 0'-0'' 0'-6" 1'-0"
SCALE: 1 1/2" = 1'-0''
LEGEND
AC
AB
CONC
LANDING LIMITS
ELEVATION POINT
WORK POINT
(E) ELECTRIC BOX
(E) BENCH ON
CONC PAD
(E) LIGHT POLE
(E) CURB, TYP
ACC PARKING
PARKING
STRIPING
(E) FENCE
(E) BLOCK
RETAINING WALL
(E) TIMBER
RETAINING WALL, SEE
(E) TIMBER
POST
(E) CONC
ABUTMENT
REPLACEMENT
AC, SEE NOTE 4
A
A
PAVED WALKWAY DEMOLITION
SCALE: 1 1/2" = 1'-0"
B
PAVED WALKWAY
SCALE: 1 1/2" = 1'-0"
(E) WALKWAY TO BE
REPLACED, SEE NOTE 4
WIDTH VARIES
2"
AC
4" A B
WALKWAY
10' FOR UPPER WALKWAY
5' FOR LOWER WALKWAY
WP9
WP10
WP11
WP12
(E) TIMBER
POST
(E) AC
(E) SIGN
(E) METER (E) BARBECUE
(E) PICNIC
TABLE
(E) HOSE
BIBB
SUBGRADE, SEE NOTE 6
TOE OF BANK
TOP OF BANK
TOP OF BANK
TOP OF BANK
TOP OF
BANK
6"
EXCAVATION
TIMBER RETAINING WALL PHOTO
SCALE: NTS
(E) WALKWAY
(E) TIMBER
RETAINING WALL,
PROTECT IN PLACE
CLEAR AND GRUB
VEGETATION
BETWEEN WALKWAY
AND TIMBER
RETAINING WALL, SEE C
0'-6" 0'-0'' 0'-3" 0'-6"
SCALE: 3" = 1'-0''
C
CLEARING AND GRUBBING
SCALE: 3" = 1'-0"
WALKWAY
(E) TIMBER
RETAINING
WALL, PROTECT
IN PLACE
WIDTH VARIES
CLEAR AND GRUB, SEE NOTE 8
WP13
WP14
WP15 WP16
(E) AC
UPPER
WALKWAY
LOWER
WALKWAY
CL ELEVATION PER PLAN
1.5% TYP / 2.0% MAX
CROSS SLOPE, SEE NOTE 7
LANDING,
SEE NOTE 5
LANDING,
SEE NOTE 5
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
M -1
.d w g D at e:
N ov em be r 1
1:
p m
V1
ABBREVIATIONS
M-1
M E
C H
A N
IC
A
L G
E N
E R
A L
N O
TE
S
A N
D A
B B
R E
V
IA
TI
O
N S
11-17-2026
J. FERNANEZ
JF
A. KONYALIAN
MECHANICAL NOTES:
1. FIRE PROTECTION PLANS MUST BE APPROVED BY THE AHJ PRIOR
TO THE INSTALLATION OF ANY PIPE. DURING CONSTRUCTION, A SET OF
APPROVED PLANS MUST BE MAINTAINED AT ALL TIMES ON THE JOB
SITE.
2. COMPLETED WORK MUST BE SUBJECTED TO A FIRE WATER
PRESSURE TEST OF 200 PSI FOR 2 HOURS, DURING WHICH THERE IS TO
BE NO REDUCTION IN TEST PRESSURE. IF A REDUCTION SHOULD
OCCUR, LEAK(S) MUST BE LOCATED, REPAIRED AND THE TEST
REPEATED. IN ADDITION, ALL NEWLY INSTALLED FIRE SERVICE LINES
MUST PASS HYDROSTATIC AND HYDRODYNAMIC TESTING
REQUIREMENTS AS PERFORMED BY THE LOCAL FIRE MARSHAL.
3. THE SYSTEM MUST ONLY EMPLOY THE USE OF APPROVED
MATERIALS AND DEVICES OF NO LESS THAN 200 PSI RATED WORKING
PRESSURE. NEW MARINA FIRE WATER PIPING MUST BE HDPE DR 9
UNLESS NOTED OTHERWISE. PLASTIC PIPING MAY BE USED IN AREAS
WHERE IT IS NOT EXPOSED TO FIRE, OTHERWISE STAINLESS STEEL
PIPING MUST BE USED.
4. PIPING MATERIAL & FIREWATER SYSTEM MUST BE IN
COMPLIANCE WITH LATEST VERSIONS OF: NFPA 14, SACRAMENTO FIRE
CODE, CALIFORNIA FIRE CODE, AND REQUIREMENTS OF AUTHORITY
HAVING JURISDICTION. ALL MATERIALS MUST BE UL LISTED WHERE
AVAILABLE.
5. FLOAT FIRE PROTECTION SYSTEMS SHALL BE PROVIDED PER THE
2022 CALIFORNIA FIRE CODE.
6. FLOAT FIRE PROTECTION SYSTEM SHALL CONSIST OF A CLASS I
MANUAL DRY STANDPIPE HOSE CONNECTION SYSTEM, PER NFPA 14
AND NFPA 303. HOSE CONNECTIONS SHALL BE PROVIDED SUCH THAT
EVERY PORTION OF THE FLOAT IS WITHIN 150 FEET OF A 2-1/2" INCH
CLASS I HOSE CONNECTION. HOSE CONNECTIONS SHALL HAVE
NATIONAL STANDARD HOSE THREADS AND CAP.
7. THE STANDPIPE SYSTEM MUST BE CAPABLE OF SUPPLYING A
FLOW OF 500 GPM TO THE HYDRAULICALLY MOST REMOTE STANDPIPE
CONNECTION AND 250 GPM FOR EACH ADDITIONAL STANDPIPE.
8. EACH STANDPIPE OUTLET SHALL BE PLACED TO PROVIDE A
MINIMUM OF 6 INCHES ON ALL SIDES OF THE HANDLE AND 18 INCHES
ON ALL SIDES OF THE OUTLET OR LOCATED AS APPROVED BY THE FIRE
CODE OFFICIAL.
9. THE CONTRACTOR SHALL VERIFY ALL CONTROLLING FIELD
DIMENSIONS BEFORE ORDERING OR FABRICATING ANY MATERIAL.
ABC ASSOCIATED BUILDERS AND CONTRACTORS
ACC ACCESSIBLE
AHJ AUTHORITY HAVING JURISDICTION
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
BV BALL VALVE
BFP BACKFLOW PREVENTION DEVICE
CHV CHECK VALVE
CSLB CONTRACTORS LICENSE BOARD
CU COPPER
DIA DIAMETER
DR DIMENSION RATIO
DWG DRAWING
(E) EXISTING
ELL ELBOW
F FIRE WATER
FDC FIRE DEPARTMENT CONNECTION
FEC FIRE EXTINGUISHER CABINET
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FWHC FIRE WATER HOSE CONNECTION
GPM GALLONS PER MINUTE
GV GATE VALVE
GV GATE VALVE IN VALVE BOX & COVER
HDPE HIGH DENSITY POLYETHYLENE
HB HOSE BIBB
IPS IRON PIPE SIZE
ISO ISOLATION
LED LIGHT EMITTING DIODE
MFR MANUFACTURER
MLW MEAN LOW WATER
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NPT NATIONAL PIPE THREAD
NSF NATIONAL SANITATION FOUNDATION INTERNATIONAL
OC ON CENTER
PEX CROSS-LINKED POLYETHYLENE
POC POINT OF CONNECTION
PPM PARTS PER MILLION
PVC POLYVINYL CHLORIDE PIPE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
RED REDUCER
SFFC SAN FRANCISCO FIRE CODE
SFFD SAN FRANCISCO FIRE DEPARTMENT
SS STAINLESS STEEL
STD STANDARD
TYP TYPICAL
UL UNDERWRITERS LABORATORIES, INC.
UNO UNLESS NOTED OTHERWISE
UP POWER PEDESTAL W/ HOSE BIBB
VIC VICTAULIC
W POTABLE WATER
W/ WITH
WL WATER LEVEL
1. CONTRACTOR SHALL HAVE A CSLB TYPE C-16 LICENSE,
REQUIRED FOR THE INSTALLATION OF THE FIRE PROTECTION SYSTEM.
SHOP DRAWINGS SHALL BE STAMPED BY A LICENSED C-16 FIRE
PROTECTION CONTRACTOR.
2. INSTALLATION OF PIPING SYSTEMS, INCLUDING COORDINATION
WITH OTHER TRADES, MUST BE COORDINATED WITH THE WATER, FIRE
AND OTHER AHJ DEPARTMENTS. PRIOR APPROVAL OF AND NOTICE TO
PROCEED WITH THE TIE-INS TO EXISTING UTILITIES ARE REQUIRED BY
THE LOCAL AHJ FOR THE WATER SYSTEM. AUTHORIZED
REPRESENTATIVE MUST WITNESS TIE-IN, AS REQUIRED.
3. ALL PIPING MUST FOLLOW THE GENERAL ARRANGEMENT
SHOWN. PIPING MUST BE RUN AS INDICATED, CARE BEING TAKEN TO
AVOID INTERFERENCE WITH OTHER PIPING, CONDUIT, OR EQUIPMENT.
THE LOCATION OF PIPING TO BE RUN ON THE DOCK MUST BE
COORDINATED WITH ELECTRICAL CONDUITS SPECIFIED. BEFORE
JOINTING AND ERECTION OF PIPING, THOROUGHLY CLEAN INTERIORS
OF PIPE AND COMPONENTS. MAINTAIN CLEANLINESS BY CLOSURE OF
PIPE OPENINGS WITH CAPS OR PLUGS.
4. OBTAIN ALL REQUIRED BUILDING/TRADE PERMITS AND PROVIDE
ALL REQUIRED TESTING.
5. ENSURE SUFFICIENT PIPE FLEXIBILITY AND ANCHORAGE IS
PROVIDED FOR ALL LINES FOR THERMAL EXPANSION AND
CONTRACTION, AND PRESSURE. THE DOCK STRUCTURE AND
COMPONENTS MUST ACCOMMODATE THE PIPING LAYOUT
REQUIREMENTS SUCH THAT THE PIPE MUST NOT BECOME
OVERSTRESSED. THE PIPING MUST BE PROPERLY SUPPORTED AND
ANCHORED.
6. INSPECT MATERIALS DELIVERED TO SITE FOR DAMAGE. UNLOAD
AND STORE WITH MINIMUM HANDLING. STORE MATERIALS ON SITE IN
ENCLOSURES OR UNDER PROTECTIVE COVERING. STORE PLASTIC
PIPING UNDER COVER OUT OF DIRECT SUNLIGHT. DO NOT STORE
MATERIALS DIRECTLY ON THE GROUND. KEEP INSIDE OF PIPES,
FITTINGS AND EQUIPMENT FREE OF DIRT AND DEBRIS. HANDLE PIPE,
FITTINGS, VALVES, AND OTHER ACCESSORIES IN SUCH MANNER AS TO
ENSURE DELIVERY TO THE INSTALLATION LOCATION IN A SOUND
UNDAMAGED CONDITION.
7. FURNISH ALL FIRE WATER MATERIALS (PIPE, VALVES, ETC.). ALL
SUCH MATERIALS MUST BE NEW, MEET DISTRICT, COUNTY, WATER
UTILITY COMPANY AND OTHER AHJ SPECIFICATION REQUIREMENTS
FOR EACH ITEM. PRIOR TO INSTALLATION, MATERIALS MUST BE
APPROVED IN WRITING BY THE ENGINEER AND AHJ.
8. SHOULD THERE BE A CONFLICT BETWEEN THESE GENERAL
NOTES, CONTRACT DRAWINGS, AND/OR CONTRACT DOCUMENTS, THE
MOST RESTRICTIVE INTERPRETATION MUST PREVAIL. THE
CONTRACTOR MUST BE RESPONSIBLE FOR OBTAINING FROM THE
ENGINEER ANY CLARIFICATION OR INTERPRETATION OF GENERAL
NOTES, CONTRACT DRAWINGS, AND/OR SPECIFICATIONS IN WRITING
AND IN ADVANCE OF THE BEGINNING OF CONSTRUCTION.
9. LOCATIONS OF UTILITIES, PUBLIC AND/OR PRIVATE, ARE
APPROXIMATE ONLY, AND THE EXACT LOCATIONS MUST BE
DETERMINED IN THE FIELD. IT IS POSSIBLE THAT SOME EXISTING
FACILITIES ARE NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR
MUST BE RESPONSIBLE FOR HAVING ALL EXISTING UTILITIES
RELEVANT TO PROJECT CONSTRUCTION LOCATED AND MARKED PRIOR
TO THE BEGINNING OF CONSTRUCTION.
10. PROVIDE ALL NECESSARY PROTECTIVE MEASURES TO PROTECT
EXISTING UTILITIES FROM DAMAGE DURING CONSTRUCTION OF THIS
PROJECT. SHOULD SPECIAL EQUIPMENT BE REQUIRED TO WORK OVER
AND AROUND THE UTILITIES, THE CONTRACTOR MUST BE REQUIRED
TO FURNISH SUCH EQUIPMENT. THE COST OF PROTECTING UTILITIES
FROM DAMAGE AND FOR FURNISHING SPECIAL EQUIPMENT MUST BE
INCLUDED IN THE BID FOR CONSTRUCTION.
11. CONTACT ALL AFFECTED UTILITY OWNERS PRIOR TO SUBMITTING
A BID TO COORDINATE SCHEDULING OF WORK FOR THE PROJECT. THE
CONTRACTOR MUST RECEIVE NO ADDITIONAL COMPENSATION FOR
ANY DELAYS OR INCONVENIENCE CAUSED BY NECESSARY UTILITY
COMPANY ADJUSTMENTS TO THE PROJECT SCHEDULE.
12. SUPPORTS AND HARDWARE SHALL BE TYPE 316 STAINLESS
STEEL. FIELD BENDING IS NOT PERMITTED. VALVE SUPPORTS SHALL BE
INSTALLED ON ADJACENT PIPING ON BOTH SIDES OF THE VALVE.
SUBMIT SHOP DRAWINGS OR CATALOG DATA FOR REVIEW AND
APPROVAL. A DIELECTRIC ISOLATION SHEET SHALL BE PLACED WHERE
DISSIMILAR METALS CONTACT ON THE SUPPORT.
13. ALL UNSUITABLE MATERIAL, AS DETERMINED BY THE ENGINEER,
OR THROUGH TESTING, SHALL BE REMOVED, LEGALLY DISPOSED, AND
REPLACED WITH SUITABLE MATERIAL, WITH CORRESPONDING
CLOSURE REPORT(S), AND ACCEPTABLE TO THE ENGINEER AND
REGULATORY AUTHORITIES.
14. DIELECTRIC COUPLINGS SHALL BE USED AT DISSIMILAR METAL
PIPING CONNECTIONS.
15. PROVIDE TEMPORARY BLOW OFF VALVES AT THE END OF EACH
WATER/FIRE LINE. DRAIN CONNECTIONS SHALL BE PROVIDED AT LOW
POINTS FOR WATER AND FIRE SYSTEMS.
FIRE WATER SYSTEM NOTES:
X
X X
X X
X X
X X
X X
X
X
X
X
X
X
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
M -2
.d w g D at e:
N ov em be r 1
1:
p m
V1
M-2
FI
R
E P
R O
TE
C
TI
O
N S
IT
E
P
LA
N
11-17-2026
J. FERNANDEZ
JF
A. KONYALIAN
CURB, TYP
-20' 0' 20' 40'
1" = 20'
FIRE PROTECTION SITE PLAN
SCALE: 1" = 20'
(E) PARKING AREA
SEE SHEET M-3 FOR DOCK FIRE WATER PLAN
SEE 2
M-5
FIRE HYDRANT. TO
BE PROVIDED BY
OTHERS.
FDC
3' MIN. SEE
NOTE 2
SEE NOTE 1
NOTES
1. DECONSTRUCT STACKABLE MASONRY UNIT
RETAINING WALL FOR FIRE LINE
INSTALLATION IN A MANNER WHICH
PRESERVES MASONRY UNIT BLOCK FOR
REINSTALLATION.
2. PROVIDE 3' MINIMUM CLEARANCE FROM
EDGE OF PAVEMENT FOR FIRE LINE
INSTALLATION.
SEE 3
M-5
0+
.0
0+
.0
0+
.0
0+
.0
1+00.00 1+25.00 1+42.75
6.37'±
PILE COORDINATES
PILE NUMBER NORTHING EASTING
P1 1803706.83 6650950.28
P2 1803759.85 6650907.69
P3 1803798.83 6650876.38
P4 1803837.81 6650845.07
P5 1803862.92 6650810.54
P6 1803829.11 6650768.44
P7 1803791.13 6650721.09
P8 1803756.16 6650743.41
P9 1803717.17 6650774.72
P10 1803678.19 6650806.03
P11 1803625.17 6650848.61
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
M -3
.d w g D at e:
N ov em be r 1
1:
p m
V1
M-3
D O
C K
F
IR
E W
A
TE
R P
LA
N
11-17-2026
J. FERNANDEZ
JF
AK
MHHW
MLLW
C-1
DOCK FIRE WATER PLAN
SCALE: 1" = 10'
10'-0" 0'-0'' 10'-0" 20'-0"
SCALE: 1''=10'
LEGEND
WORK POINT
FIRE EXTINGUISHER CABINET
(FEC) ( TOTAL 7 )
(E) GANGWAY
ABUTMENT
A M-4
NOTES
1. FIRE HOSE STANDPIPES ARE SPACED PER
NFPA 14 REQUIREMENTS FOR MARINAS.
CONTRACTOR IS RESPONSIBLE FOR
SUBMITTING SHOP DRAWINGS
DEMONSTRATING THE PROPOSED
DIMENSIONS OF INSTALLATION SUBJECT TO
REVIEW AND CONFIRMATION.
2. PIPE ROUTING SHALL BE INSTALLED AS TO
AVOID CONTACT WITH PILES.
ACC
SLIP
ACC
SLIP
104'-7"
104'-7"
5'-11"
4" HDPE SDR9 PIPE
4" HDPE SDR9 PIPE
6" HDPE SDR9 PIPE
STANDPIPE RISER W/
FIRE EXTINGUISHER
6" PVC DR 21 PIPE
6" X 4" HDPE IPS BUTT
REDUCER (TYP)
STANDPIPE RISER W/
FIRE EXTINGUISHER
STANDPIPE RISER
STANDPIPE RISER
SEE 1
M-5
75'-0" (TYP)
P1P2P3P4
P5
P6
P8 P9 P10 P11
P7
6" HDPE IPS BUTT 45°
ELBOW (TYP)
36'-0"
36'-0"
9' -8
6' -9
3'-5"
4'-0"
8'
-8
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
M -4
.d w g D at e:
N ov em be r 1
1:
p m
V1
M-4
FI
R
E P
R O
TE
C
TI
O
N E
LE
V
A
TI
O N
S
11-17-2026
J. FERNANDEZ
JF
AK
NOTES
1. IN THE ELEVATION VIEW, DOCK AND LANDING RAMP
LEGS ARE NOT SHOWN FOR THE HIGHEST
ACCESSIBLE TIDE FOR CLARITY.
(E) ABUTMENT
DECKING OF
(E) GANGWAY
ABUTMENT EL +7.80
(E) GANGWAY
(E) RAMP
LANDING
DOCK
HIGHEST ACCESSIBLE TIDE
EL +4.30'
LOWEST ACCESSIBLE TIDE
EL -0.70'
1:12
SLOPE
1:12
SLOPE
A M-3
ELEVATION - GANGWAY PIPE CONNECTION
SCALE: 3/4" = 1'-0"
C-1
2'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 3/4"=1'-0''
6" CORRUGATED
DOUBLE BRAIDED
METAL HOSE. 5'
LIVE LENGTH W/
25" MIN BEND
RADIUS.
6" 316 SS SCH 40
PIPE
6" CORRUGATED
DOUBLE BRAIDED
METAL HOSE.
9-1/2' LIVE
LENGTH W/ 25"
MIN BEND RADIUS
SS RIGID
COUPLING (TYP)
6" PVC DR 21 PIPE
TO FDC. ON
FARSIDE
6" LONG RADIUS
316 SS SCH 40
ELBOW (TYP)
6" HDPE SDR 9 PIPE
TO FLOATING DOCK
6" HDPE-TO-STEEL
GROOVED TRANSITION
COUPLING
6" PVC-TO-STEEL
GROOVED TRANSITION
COUPLING
SUPPORTS SHALL
BE SPACED A
MAXIMUM OF 15
FEET
5' -0
" M A
X
2' -7
1'
-6 " M
IN
FDC
CLASS I STANDPIPE
BRANNAN ISLAND MARINA
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
M -5
.d w g D at e:
N ov em be r 1
1:
p m
V1
M-5
FI
R
E P
R O
TE
C
TI
O
N D
E
TA
IL
S
11-17-2026
J. FERNANDEZ
JF
AK
NOTES
1. THRUST BLOCK SHOWN IN DETAIL 2 IS SCHEMATIC
ONLY. PROVIDE CONCRETE THRUST BLOCK PER
(2024) NFPA 24 & (2022) CALIFORNIA PLUMBING CODE.
THE CONTRACTOR SHALL SUBMIT THRUST BLOCK
DESIGN CALCULATIONS TO THE AUTHORITY HAVING
JURISDICTION FOR REVIEW AND APPROVAL PRIOR TO
CONSTRUCTION.
2. FOR STANDPIPE RISERS ON THE 6" HDPE SDR9 FIRE
MAIN USE A 6" X 3" HDPE IPS BUTT REDUCER. ADJUST
BRACKET TYPE / SPACING AS REQUIRED TO
ACCOMMODATE PIPE SIZE.
M-3
DETAIL - STANDPIPE AND FIRE EXTINGUISHER CABINET
SCALE: 1" = 1'-0"
2-1/2" ANGLE BRASS
VALVE HOSE
CONNECTION (175 PSI
MIN. RATING)
STANDPIPE HOSE
OUTLET LOCKING CAP
1' -6
" M
IN
PROVIDE MIN. 18"
CLEARANCE ON ALL
SIDES OF THE HOSE
OUTLET
DRY CHEMICAL FIRE
EXTINGUISHER &
CABINET
2-1/2" 316 SS RISER
STEEL BRACKET
1'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 1"=1'-0''
2-1/2" 316 SS GROOVED
RIGID COUPLING
3" X 2-1/2" 316 SS
GROOVED CONCENTRIC
REDUCER
3" 316 SS GROOVED
RIGID COUPLING
3" 316 SS RISER
3" HDPE-TO-STEEL
GROOVED TRANSITION
COUPLING
4" X 3" HDPE IPS BUTT
REDUCER, SEE NOTE 2
4" HDPE SDR9 FIRE WATER
MAIN, SEE NOTE 2
FREE STANDING 3-WAY
FIRE DEPT. INLET
CONNECTION 6" X 2-1/2"
X 2-1/2" X 2-1/2"
FDC LOCKING CAP
6" 3'
M
IN
. D E
P
TH
O F
B U
R Y
T O
F
FS
6" SPOOL
3' X 3' CONCRETE
FOUNDATION
#4 REBAR
CONCRETE THRUST
BLOCK
" T
O
8"
SIGN IDENTIFYING TYPE
OF SYSTEM AND AREA
SERVED. SIGN SHALL BE
MOUNTED ON THE FDC
SPOOL / RISER
M-2
DETAIL - FIRE DEPARTMENT CONNECTION
SCALE: N.T.S.
SEE NOTE 2 FOR 6"
MAIN
SEE PLAN FOR LOCATIONS
THAT INCLUDE FIRE
EXTINGUISHER
M-2
DETAIL - FIRE WATER TRENCH
SCALE: 1-1/2" = 1'-0"
WARNING TAPE
6"Ø PVC DR 21 PIPE
PEA GRAVEL
95% SAND PROCTOR
85% BACKFILL
PROCTOR
6"
6" 9"
9"
3' -0
" M
IN
E le va tio n
-0+05 0+00 0+25 0+50 0+75
S
TA
+0
6"
E
LB
O
W C
O N
N E
C T
TO
H
O R
IZ
O
N
TA
L P
IP
E
A N
D 6"
°E
LB
O W
T O
F D
C R
IS
E
R . S
E E
P
LA
N O
N S
H E
E T
M -2
S
TA
+7
6.
6"
E
LB
O W
IN
V
7.
E le va tio n
1+00 1+25 1+47
S
TA
+8
5.
6"
.5
0° E
LB
O
W
IN
V
7.
S
TA
+9
1.
6"
.5
0° E
LB
O
W
IN
V
5.
S
TA
+9
9.
6"
.5
0° E
LB
O
W
IN
V
5.
S
TA
+2
6.
6"
.5
0° E
LB
O
W
IN
V
.4
S
TA
+3
5.
6"
E
LB
O W
IN
V
.2
S
TA
+3
6.
6"
E
LB
O W
IN
V
.4
S
TA
+4
2.
6"
E
LB
O W
IN
V
.6
E le va tio n
-0+05
E le va tio n
1+47
Station
Station
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
ACCESSIBILITY COMPLIANCE AND STATE FIRE
MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE
DEPARTMENT OF PARKS AND RECREATION,
NORTHERN SERVICE CENTER
CERTIFICATION #
Reviewed by Date
FACILITIES AND
DEVELOPMENT DIVISION
PROJECT MILESTONE: 100%
207833.
B R
A N
N A
N
IS
LA
N
D M
A R
IN
A
R E
S
TO
R A
TI
O
N B
R A
N N
A N
IS
LA
N D
S
TA
TE
P
A R
K
Fi le
: P :\W
C \9
0-n3 br an no n is la nd \2
C
A D
D
A ct iv e\
_s he et se t\9
0N
M -6
.d w g D at e:
N ov em be r 1
1:
p m
V1
M-6
FI
R
E W
A
TE
R P
R O
FI
LE
11-17-2026
J. FERNANDEZ
JF
AK
M-2
FIRE WATER PROFILE 1
SCALE: 1" = 5'
EXISTING GRADE
M-2
FIRE WATER PROFILE 2
SCALE: 1" = 5'
5' 0' 5' 10'
SCAL…