Drawings_C26863039.pdf

PDF 6 MB Posted

Attached to
C26863039 BRANNAN ISLAND SRA - Marina Rehabilitation
Solicitation number
0000041004
Issued by
Sacramento County, California

About this file

This document is a comprehensive set of construction drawings for the Brannan Island Marina Restoration project, prepared by the California Department of Parks and Recreation, Facilities and Development Division, in coordination with the design firm Moffatt & Nichol. The project involves the restoration and modernization of marina facilities at Brannan Island State Park located at 17645 CA-160, Rio Vista, California. Major work components include demolition of existing docks and timber piles; furnishing and installation of a new aluminum dock system with steel pipe guide piles; installation of a security gate and security camera; reuse of the existing gangway and ramp landing structure; dredging and storage of dredged material to a minimum depth of -6.0 feet MLLW with potential overdredging to -8.0 feet; installation of replacement LED luminaire and fire standpipe system; and parking lot and pathway improvements. The project encompasses approximately 243,000 square feet of total area, with the new marina dock occupying 5,610 square feet. The dredging plan identifies quantities of 3,550 cubic yards for primary dredging, 1,850 cubic yards for side slope sloughing, and 2,900 cubic yards of potential overdredging. The facility will include 29 total boat slips with 2 accessible slips per code requirements and will be classified as occupancy type U construction with type V-B construction classification.

The project must comply with the 2025 California Building Code, 2025 California Fire Code, 2025 California Electrical Code, 2005 California Division of Boating and Waterways Layout and Design Guidelines, and NFPA standards including NFPA 14 and NFPA 303 for fire protection in marinas. The fire protection system consists of a Class I Manual Dry Standpipe Hose Connection System with 2.5-inch hose connections spaced to ensure every portion of the float is within 150 feet of a connection. The system must be capable of supplying 500 GPM to the hydraulically most remote standpipe connection and 250 GPM for each additional standpipe. All materials, including piping and components, must be new and rated for minimum 200 PSI working pressure, with plastic piping limited to non-exposed areas and stainless steel piping used in exposed fire protection applications. The completed fire water system must pass hydrostatic testing at 200 PSI for 2 hours with no pressure reduction. The contractor must hold a California State Contractors License Board Type C-16 license for fire protection installation, and all shop drawings must be stamped by a licensed C-16 contractor and approved by the Authority Having Jurisdiction prior to installation.

View the file

Other files

File Type Posted
Bid_Forms_C26863039.pdf PDF
Project_Manual_C26863039.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

G -1

.d w g D at e:

N ov em be r 1

1:

p m

V1

CALIFORNIA DEPARTMENT OF PARKS AND RECREATION

FACILITIES AND DEVELOPMENT DIVISION

SITE ADDRESS

SCOPE OF WORK

PREPARED BY

STATE OF CALIFORNIA

DEPARTMENT OF PARKS AND RECREATION

FACILITIES AND DEVELOPMENT DIVISION

NORTHERN SERVICE CENTER

2241 HARVARD ST, SUITE 200

SACRAMENTO, CA 95815

BRANNAN ISLAND STATE PARK

BRANNAN ISLAND MARINA RESTORATION

SFM PERMIT NUMBER 26-N-4392-CP

THE MAJOR COMPONENTS OF THE BRANNAN ISLAND MARINA RESTORATION ARE TO: DEMOLISH

EXISTING DOCKS AND PILES, FURNISH AND INSTALL A NEW DOCK SYSTEM AND GUIDE PILES,

FURNISH AND INSTALL A SECURITY GATE, REUSE THE EXISTING GANGWAY AND RAMP LANDING

STRUCTURE, DREDGE AND STORE DREDGED MATERIAL, INSTALL A SECURITY CAMERA, FURNISH

AND INSTALL AN LED LUMINAIRE FURNISH, AND INSTALL A FIRE STANDPIPE SYSTEM.

MOFFATT & NICHOL

2185 NORTH CALIFORNIA BLVD, SUITE 500

WALNUT CREEK, CA 94596

BRANNAN ISLAND STATE PARK

17645 CA-160

Rio Vista, CA 94571

VICINITY MAP

LOCATION MAP

G-1

TI

TL

E S

H E

E T

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

SHEET INDEX

INDEX NO. DRAWING

NO. SHEET NAME

1 G-1 TITLE SHEET

2 G-2 GENERAL NOTES, ABBREVIATIONS, LEGEND, CROSS

REFERENCE AND DATUMS

3 G-3 SITE PHOTOS

4 G-4 EXISTING SITE PLAN

5 G-5 SEDIMENT STORAGE & STAGING SITE PLAN

6 C-1 PROJECT SITE PLAN

7 C-2 DEMOLITION PLAN

8 C-3 DREDGING PLAN - EXISTING BATHYMETRY

9 C-4 DOCK AND PILE PLAN

10 C-5 DOCK AND PILE SECTIONS AND DETAILS

11 C-6 GANGWAY, RAMP LANDING SECTION AND DETAILS

12 C-7 SECURITY GATE - ABUTMENT SECTIONS AND DETAILS

13 C-8 SEDIMENT STORAGE SITE DETAILS

14 C-9 SECURITY CAMERA AND LUMINAIRE DETAILS

15 C-10 PARKING LOT DETAILS

16 C-11 PATH REPAVING

17 M-1 MECHANICAL GENERAL NOTES AND ABBREVIATIONS

18 M-2 FIRE PROTECTION SITE PLAN

19 M-3 DOCK FIRE WATER PLAN

20 M-4 FIRE PROTECTION ELEVATIONS

21 M-5 FIRE PROTECTION DETAILS

22 M-6 FIREWATER PROFILE

CODES AND GUIDELINES

ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF THE FOLLOWING LISTED CODES &

STANDARDS, AND ALL OTHERS HAVING JURISDICTION OVER THE WORK.

· 2025 CA BUILDLING CODE (CBC) TITLE 24, PART 2.

· 2005 CA DIVISION OF BOATING AND WATERWAYS LAYOUT AND DESIGN GUIDELINES FOR

MARINA BERTHING FACILITIES.

· 2025 CA ELECTRICAL CODE (CEC) TITLE 24, PART 3.

· 2025 CA FIRE CODE (CFC) TITLE 24, PART 9.

· 2026 NFPA 303, FIRE PROTECTION STANDARD FOR MARINAS AND BOATYARDS.

BUILDING CODE ANALYSIS (CSFM LIST) MARINA DOCK

1 OCCUPANCY CLASSIFICATION U

2 BUILDING CONSTRUCTION TYPE V-B

3 NUMBER OF STORIES N/A

4 ACTUAL BUILDING HEIGHT N/A

5 BUILDING AREA IN SQUARE FEET 5,610 SF

6 AREA OF PROJECT IN SQUARE FEET 243,000 SF

7 SEPARATED OR NON-SEPARATED USE N/A

8 ALLOWABLE AREA PER CBC N/A

9 AREA INCREASE N/A

10 HEIGHT INCREASE N/A

FIRE SPRINKLERS

TYPE: (WET, DRY, PRE-ACTION OR DELUGE) N/A

FIRE ALARM

TYPE: (MANUAL, AUTOMATIC, ETC) N/A

13 OTHER FIRE PROTECTION SYSTEMS, IF ANY

CLASS I MANUAL DRY

STANDPIPE HOSE

CONNECTION SYSTEM

(NFPA 14 & 303)

14 SMOKE CONTROL SYSTEM N/A

15 OCCUPANT LOAD FOR ENTIRE BUILDING AND

EACH FLOOR N/A

16 YEAR BUILDING WAS CONSTRUCTED NEW BUILD

17 IN A HIGH FIRE HAZARD SEVERITY ZONE? NO

18 SEISMIC JOINTS N/A

EMERGENCY RESPONDER RADIO COVERAGE

(YES OR NO) N/A

20 HIGH-RISE (YES OR NO) N/A

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

G -2

.d w g D at e:

N ov em be r 1

1:

p m

V1

CROSS-REFERENCE LEGEND

NOTE: LETTER INDICATES SECTION; NUMBER INDICATES PLAN,

ELEVATION, OR DETAIL. WHERE THERE IS NO

REFERENCE SHEET INDICATED, IT MEANS THE DETAIL OR

SECTION IS TAKEN AND SHOWN ON THE SAME SHEET.

CXX

SAMPLE VIEW TITLE

SCALE: XX"=XX'

A

CXX

VIEW NUMBER

SHEET NUMBER VIEW

REFERENCED FROM

VIEW TITLE

SECTION CALLOUT

VIEW NUMBER

SHEET NUMBER VIEW

REFERENCED TO

DETAIL CALLOUT

VIEW NUMBER

SHEET NUMBER VIEW

REFERENCED TO

KEYED NOTE

CXX

AB AGGREGATE BASE

AC ASPHALT CONCRETE

ACC ACCESSIBLE

APPROX APPROXIMATELY

CA CALIFORNIA

CBC CALIFORNIA BUILDING CODE

CL CENTERLINE

CLR CLEAR

CONC CONCRETE

DHW DESIGN HIGH WATER

DIA DIAMETER

DLW DESIGN LOW WATER

DR DIMENSION RATIO

(E) EXISTING

EG EXISTING GRADE

EL ELEVATION

EQ EQUAL

EW EACH WAY

F&I FURNISH AND INSTALL

FB FREEBOARD

FDC FIRE DEPARTMENT CONNECTION

FEC FIRE EXTINGUISHER CABINET

FT FEET

H HORIZONTAL

HDPE HIGH-DENSITY POLYETHYLENE

MAX MAXIMUM

MHHW MEAN HIGHER HIGH WATER

MHW MEAN HIGH WATER

MIN MINIMUM

MLLW MEAN LOWER LOW WATER

MLW MEAN LOWER WATER

MSL MEAN SEA LEVEL

NAD83 NORTH AMERICAN DATUM 1983

NAVD88 NORTH AMERICAN VERTICAL DATUM 1988

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NOAA NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION

NTS NOT TO SCALE

OC ON CENTER

POT. PATH OF TRAVEL

R RADIUS

SAP SEDIMENTARY ANALYSIS PLAN

SF SQUARE FEET

SLR SEA LEVEL RISE

SQ SQUARE

SS 316 STAINLESS STEEL

TOT TOTAL

TYP TYPICAL

UHMW ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE

UON UNLESS OTHERWISE NOTED

V VERTICAL

ABBREVIATIONS

G-2

G E

N E

R A

L N

O

TE

S , A

B B

R E

V

IA

TI

O

N S

LE

G E

N D

, C R

O S

S R

E

FE

R E

N C

E A

N D

D A

TU

M

S

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

GENERAL NOTES VERTICAL DATUM

1. PROJECT ELEVATIONS ARE BASED ON MLLW.

2. THE ESTIMATED TIDAL DATUMS AT BRANNAN ISLAND STATE PARK ARE AS FOLLOWS:

3. THE ASTRONOMICAL TIDE DATA IS FROM NOAA (2022), STATION 9415193 - THREEMILE

SLOUGH, SAN JOAQUIN, CA. INFORMATION ON THE 200-YEAR FLOOD IS DETERMINED

FROM THE FLOOD EMERGENCY RESPONSE INFORMATION EXCHANGE (FERIX).

TIDAL DATUM

WATER ELEVATION

(FT, MLLW)

DESIGN HIGH WATER (DHW) (200-YEAR FLOOD) 8.00

HIGHEST ASTRONOMICAL TIDE (HAT) 4.34

MEAN HIGHER HIGH WATER (MHHW) 3.42

MEAN HIGH WATER (MHW) 2.94

MEAN SEA LEVEL (MSL) 1.76

MEAN LOW WATER (MLW) 0.52

MEAN LOWER LOW WATER (MLLW) 0.00

LOWEST ASTRONOMICAL TIDE (LAT) / DESIGN LOW WATER (DLW) -0.97

NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) -1.80

1. ALL MATERIALS SHOWN OR NOTED ON THE PLANS ARE NEW UNLESS NOTED OTHERWISE.

2. THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS SHOWN OR

DIMENSIONED HERE. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE

STATE REPRESENTATIVE FOR RESOLUTION BEFORE PROCEEDING WITH THAT PORTION OF THE

WORK.

3. CONDUCT ALL WORK IN ACCORDANCE WITH THE LATEST SAFETY RULES AND REGULATIONS OF

ALL AUTHORITIES AND AGENCIES HAVING JURISDICTION OVER THE WORK.

4. ALL WORK SHALL BE IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS. WHERE

DETAILED INFORMATION OR CLARIFICATION IS REQUIRED, THE MATTER SHALL BE REFERRED TO

THE STATE REPRESENTATIVE FOR WRITTEN RESOLUTION.

5. THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS, BUT SHALL RELY ONLY ON THE WRITTEN DIMENSIONS. IF A DISCREPANCY OCCURS OR NO DIMENSION IS GIVEN, THE CONTRACTOR SHALL

NOTIFY THE STATE REPRESENTATIVE FOR WRITTEN CLARIFICATION BEFORE PROCEEDING WITH

THAT PORTION OF THE WORK.

6. THE OFFICIAL CONTRACT DRAWINGS ARE 24" X 36". SCALES LISTED ARE APPLICABLE TO THAT

SIZE AND MUST BE ADJUSTED ACCORDINGLY WHERE REDUCED SIZE DRAWINGS ARE

REFERENCED.

7. ABSENCE OF A SPECIFICATION SECTION FOR AN ITEM SHOWN ON THE DRAWINGS DOES NOT

RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE SUCH ITEM.

8. DEMOLITION OF EXISTING FEATURES SHALL BE LIMITED TO THE ITEMS SHOWN ON THE PLANS AND DESCRIBED IN THE SPECIFICATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO

REPAIR AND/OR REPLACE EXISTING FEATURES TO REMAIN THAT ARE DAMAGED BY THE

CONTRACTOR.

9. PROVIDE CONSTRUCTION SITE SECURITY FOR THE DURATION OF THE CONTRACT PERIOD AND

AS SPECIFIED.

10. FURNISH, INSTALL AND MAINTAIN ALL WARNING SIGNS AND DEVICES NECESSARY TO

SAFEGUARD THE GENERAL PUBLIC AND THE WORK, AND PROVIDE PROPER AND SAFE ROUTING

OF MARINE, VEHICULAR, AND PEDESTRIAN TRAFFIC DURING THE PERFORMANCE OF THE WORK.

THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND SHALL NOT BE LIMITED TO WORKING

HOURS.

11. KEEP THE PROJECT SITE IN A NEAT AND ORDERLY CONDITION, FREE OF RUBBISH AND DEBRIS, AT ALL TIMES.

12. REPRESENTATIVES OF CALIFORNIA STATE PARKS SHALL BE ALLOWED ACCESS DURING

CONSTRUCTION WORK.

13. PROJECT CONTROL:

· HORIZONTAL: NAD83 ZONE 2

· VERTICAL: MLLW

CONCRETE ANCHORS AND THREADED RODS

1. CONCRETE ANCHORS AND THREADED RODS SHALL BE 316 STAINLESS STEEL. ALL NUTS AND

WASHERS SHOULD ALSO BE 316 STAINLESS STEEL.

2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.

3. THE CONCRETE ANCHOR SHALL BE STAINLESS-STEEL TITEN HD BY SIMPSON STRONG-TIE, OR

APPROVED EQUAL.

EPOXY GROUT

1. EPOXY GROUT FOR THREADED ANCHOR RODS SHALL BE INSTALLED PER MANUFACTURER'S

RECOMMENDATIONS.

ABUTMENT TIMBER

1. TIMBER DECKING FOR THE ABUTMENT SHALL BE CONSTRUCTION HEART REDWOOD.

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

G -3

.d w g D at e:

N ov em be r 1

1:

p m

V1

G-3

S

IT

E P

H O

TO

S

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

BOAT LAUNCH RAMP

234 5

SITE PHOTOS INDEX

SCALE: NTS

PHOTO 1 - DOCK DAMAGE

SCALE: NTS

PHOTO 2 - ENTRY CHANNEL

SCALE: NTS

PHOTO 3 - FINGER DOCKS

SCALE: NTS

PHOTO 4 - RAMP LANDING

SCALE: NTS

PHOTO 5 - OVERGROWTH

SCALE: NTS

PHOTO 6 - OVERGROWTH

SCALE: NTS

PHOTO 7 - GANGWAYABUTMENT

SCALE: NTS

PHOTO 8 - OVERVIEW

SCALE: NTS 3

MARINA

X

X

X X

X X

X X

X X

X X

X

X

X

X

X

X

DPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

G -4

.d w g D at e:

N ov em be r 1

1:

p m

V1

G-4

E X

IS

TI

N G

S

IT

E P

LA

N

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

PATH, TYP

BUILDING

TIMBER GUIDE PILE, TYP

GANGWAY

GLULAM DOCKS, TYP

TOP OF BANK

TOP OF BANK

TOE

RETAINING WALL

WIRE FENCE

CURB, TYP

NOTES

1. ALL FEATURES SHOWN ARE EXISTING UON.

2. FEATURES SHOWN BASED ON SURVEY

PERFORMED ON 8/19/2024 BY STEPHEN

GUAY.

MHHW

MLLW

-20' 0' 20' 40'

1" = 20'

LIGHT POLE

TIMBER RETAINING WALL

GANGWAY

ABUTMENT

EXISTING SITE PLAN

SCALE: 1" = 20'

(E) PARKING AREA

RAMP LANDING

ACC

PARKING

STRIPING FOR

PARKING, TYP

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

G -5

.d w g D at e:

N ov em be r 1

1:

p m

V1

G-5

S E

D

IM

E N

T S

TO

R

A G

E

S

TA

G

IN

G S

IT

E

P

LA

N

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

5-100' 0' 100' 200'

1" = 100'

POTENTIAL HAUL

PATH, SEE NOTE 2

DREDGE SEDIMENT STORAGE

APPROX SURFACE AREA OF

175,000 SF, SEE NOTE 1

DREDGE AREA

DREDGE SEDIMENT STORAGE PLAN

SCALE: 1" = 100'

NOTES

1. FINAL SEDIMENT STORAGE AREA TO BE

DETERMINED BY THE STATE'S REPRESENTATIVE.

2. PROTECT PAVEMENT ON HAUL ROUTE WITH

SUFFICIENT MEASURES TO PREVENT DAMAGE.

REPAIR ANY DAMAGES THAT MAY RESULT.

3. CONTRACTOR TO COORDINATE PLACEMENT OF

TEMPORARY ACCESS ROAD WITH THE STATE'S

REPRESENTATIVE. CONTRACTOR TO ANTICIPATE

HAVING TO PLACE AGGREGATE BASE FOR

TEMPORARY ROAD SURFACING TO ACCESS

SEDIMENT STORAGE AREA. TEMPORARY ACCESS

ROAD TO BE REMOVED BY THE CONTRACTOR

WHEN HAULING IS COMPLETE.

4. AVOID DAMAGE OR INTRUSION INTO THE FUTURE

WATER TANK STORAGE AREA.

5. CONTINUOUS ACCESS TO BE MAINTAINED TO THE

RV CAMPSITE CONNECTED TO THE PARKING AREA.

CONTRACTOR EFFORTS SHALL NOT BLOCK THE

ROADWAY FOR VEHICULAR INGRESS AND EGRESS

TO THE RV CAMPSITE.CONTRACTOR

STAGING AREA,

APPROX 25,800 SF

CONTRACTOR

PARKING AREA,

SEE NOTE 5

C-8

FUTURE WATER TANK

STORAGE AREA, SEE NOTE 4

TEMPORARY ACCESS

ROAD, SEE NOTE 3

(E) RV CAMPSITE

X

X X

X X

X X

X X

X X

X

X

X

X

X

X

DPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -1

.d w g D at e:

N ov em be r 1

1:

p m

V1

C-1

P R

O

JE

C T

S

IT

E P

LA

N

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

(E) PATH, TYP

(E) PARKING AREA

(E) BUILDING

(E) TOP OF BANK

(E) TOP OF BANK

(E) TOE

(E) RETAINING WALL

(E) WIRE FENCE

(E) CURB, TYP

MHHW

MLLW

-20' 0' 20' 40'

1" = 20'

(E) LIGHT

POLE

(E) TIMBER

RETAINING WALL

KEY NOTES

F&I ALUMINUM DOCK SYSTEM, SEE

REUSE GANGWAY AND LANDING RAMP, SEE

F&I STEEL PIPE PILES, SEE

F&I SECURITY GATE, SEE

FURNISH CAMERA ON LIGHT POLE AND F&I LUMINAIRE,

SEE

SEDIMENT REMOVAL, SEE

F&I PARKING IMPROVEMENTS, SEE

F&I REPLACEMENT AC FOR PATHS, SEE

F&I FIRE STANDPIPE SYSTEM, SEE M-SHEETS

PROJECT SITE PLAN

SCALE: 1" = 20'

PROJECT CONTROL

WORK POINT NORTHING EASTING ELEVATION

WP1 1803914.90 6650887.59 18.06

WP2 1803983.18 6650730.66 23.96

WP3 1803853.15 6650672.05 24.69

WP4 1803770.60 6650599.44 25.93

WP5 1803961.82 6650937.56 17.76

WP6 1803758.62 6651016.53 17.83

WP7 1803860.10 6650892.89 11.69

WP8 1803873.84 6650739.40 14.39

WP1

WP2

WP3

WP4

WP5

WP6

WP7

WP8

LEGEND

WORK POINT

FEC

CLEAT

ACC POT.

AC REPLACEMENT

CONC

C-4

C-4

A C-6

A C-7

C-9

C-3

ACC

SLIP

ACC

SLIP

ACC POT.

, TYP3

PARKING

SPACE, TYP

, TYP9

FDC

ACC PARKING

FIRE HYDRANT,

NIC

C-10

C-11

AC WALKWAY

(E) AC WALKWAY

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -2

.d w g D at e:

N ov em be r 1

1:

p m

V1

DEMO (E) TIMBER GUIDE PILE, TYP

SEE NOTE 2

DEMO (E) GLULAM DOCK, TYP

SEE NOTE 3

(E) GANGWAY,

SEE NOTE 1

(E) RAMP LANDING,

SEE NOTE 1

NOTES

1. REMOVE GANGWAY AND RAMP LANDING AND

PROTECT FOR REUSE.

2. PULL THE ENTIRE LENGTH OF THE TIMBER PILE.

IF THE PILE BREAKS WITHOUT FULL

EXTRACTION, CUT PILE 2 FEET BELOW THE

AFTER DREDGE MUDLINE. 10 TOTAL

3. DEMOLISH GLULAM DOCKS - APPROX 6200 SF.

4. THE EXISTING PUMPOUT UNIT HAS A

DISCHARGE PIPELINE AND ELECTRICAL

CONNECTION, IT IS ASSUMED THAT THESE ARE

DISCONNECTED. DEMOLISH ANY UTILITIES

FOUND IN THE BASIN.

MHHW

MLLW

LEGEND

DOCK DEMOLITION

DEMOLITION PLAN

SCALE: 1" = 10'

C-2

D E

M O

LI

TI

O N

P

LA

N

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

10' 0' 10' 20'

SCALE: 1''=10'

DEMO (E) PUMPOUT

SEE NOTE 4

REMOVE (E) TIMBERS

ON THE (E) ABUTMENT

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -3

.d w g D at e:

N ov em be r 1

1:

p m

V1

C-3

D R

E D

G

IN

G P

LA

N

E

X

IS

TI

N

G B

A

TH

Y M

E

TR

Y

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

NOTES

1. EXISTING FEATURES NOT SHOWN IN PLAN VIEW

FOR CLARITY. DOCK SHOWN TO PROVIDE

REFERENCE, PERFORM DREDGE PRIOR TO

DOCK INSTALLATION.

2. DREDGE TO -6' MLLW MIN. ANY AMOUNT

DREDGED PAST THIS DEPTH WILL NOT BE PAID

FOR. DO NOT DREDGE PAST -8' MLLW. THE

LIMITS OF THE DREDGE ARE TO THE TOE OF THE

REVETMENT AND THE -6' CONTOUR ON THE

OUTLET SIDE AS SHOWN.

3. DREDGE SIDE SLOPE MATERIAL THAT SLOUGHS

WITHIN DREDGE BOUNDARY. THE EXTENTS OF

SIDE SLOUGHING SHOWN ARE SCHEMATIC.

4. ENTRANCE CHANNEL BOTTOM WIDTH TO BE 40'

MIN. ADDITIONAL DREDGING OF THE ENTRANCE

CHANNEL BOTTOM WIDTH TO REVETMENT TOE

WILL BE COMPENSATED, IF ORDERED BY THE

STATE REPRESENTATIVE.

5. DO NOT UNDERMINE THE REVETMENT. STOP

WORK SHOULD REVETMENT SLOPE BEGIN TO

FAIL AND NOTIFY THE STATE REPRESENTATIVE.

6. IF ROCK IS ENCOUNTERED WITHIN THE DREDGE

FOOTPRINT, THE CONTRACTOR SHALL NOTIFY

THE STATE REPRESENTATIVE.

7. THE ROCK SLOPE AND EXTENTS ARE ESTIMATED

BASED ON LIMITED SURVEY DATA AND VISUAL

OBSERVATIONS. THE ACTUAL REVETMENT

LAYOUT MAY VARY. THERE ARE NO AVAILABLE

AS-BUILTS.

8. THE PERMITTED DREDGE QUANTITY

REPRESENTS DREDGING FROM THE TOP OF THE

BANK DOWN TO -8' MLLW WITH SIDE SLOPE

SLOUGHING. THIS QUANTITY IS NOT TO BE USED

FOR CONSTRUCTION.

-20' 0' 20' 40'

1" = 20' E

N

TR

A N

C E

C H

A N

N E

L S

E E

N O

TE

APPROX (E) TOE OF

REVETMENT AS

DREDGE BOUNDARY,

SEE NOTE 2

DOCK, TYP

GUIDE PILE, TYP

POTENTIAL SIDE

SLOPE SLOUGHING,

SEE NOTE 3

DHW

EL 8.00'

DLW

EL -0.97'

EG

(E) REVETMENT

TOE OF (E)

REVETMENT

DESIGN MINIMUM DREDGE DEPTH

EL -6.0' MLLW, TYP

DOCK

ENTRANCE CHANNEL

SEE NOTE 4

(E) REVETMENT, TYP

EG, TYP

POTENTIAL SIDE

SLOPE SLOUGHING,

SEE NOTE 3, TYP

DLW

EL -0.97'

0'

-5'

5'

10'

15'

TOE OF (E)

REVETMENT, TYP

-5' 0' 5' 10'

1" = 5'

C-1

DREDGING PLAN

SCALE: 1" = 20'

A

SECTION - SIDE SLOPE

SCALE: 1" = 5'

B

SECTION - ENTRANCE CHANNEL

SCALE: 1" = 5'

A

B

0'

-0

236'-0"

8'-0"

6' -0

6' -0

MAXIMUM DREDGE DEPTH

EL -8.0' MLLW, TYP

DESIGN MINIMUM DREDGE DEPTH

EL -6.0' MLLW, TYP

MAXIMUM DREDGE DEPTH

EL -8.0' MLLW, TYP

LEGEND

POTENTIAL SIDE SLOPE SLOUGHING

REQUIRED DREDGING

APPROX TOE OF

REVETMENT

APPROX TOE OF

REVETMENT, TYP

DREDGE TO -6' MLLW,

SEE NOTE 2 DREDGE

BOUNDARY

LIMIT AT

OUTLET

POTENTIAL SIDE

SLOUGHING, SEE NOTE 3

QUANTITIES

DREDGE TO -6' 3,550 CY

DREDGE OF SIDE SLOPE

SLOUGHING (2H:1V) 1,850 CY

OVERDREDGE FROM -6' TO -8' 2,900 CY

PERMITTED DREDGE

(NOT FOR CONSTRUCTION) 15,200 CY

APPROX TOP OF BANK

PERMITTED DREDGE

BOUNDARY, SEE NOTE 8

PILE COORDINATES

PILE NUMBER NORTHING EASTING

P1 1803706.83 6650950.28

P2 1803759.85 6650907.69

P3 1803798.83 6650876.38

P4 1803837.81 6650845.07

P5 1803862.92 6650810.54

P6 1803829.11 6650768.44

P7 1803791.13 6650721.09

P8 1803756.16 6650743.41

P9 1803717.17 6650774.72

P10 1803678.19 6650806.03

P11 1803625.17 6650848.61

DPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -4

.d w g D at e:

N ov em be r 1

1:

p m

V1

C-4

D O

C K

A N

D P

IL

E

P

LA

N

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

MHHW

MLLW

C-1

DOCK AND PILE PLAN

SCALE: 1" = 10'

10' 0' 10' 20'

SCALE: 1''=10'

LEGEND

FEC ( TOTAL 7 )

CLEAT24'-0"

TYP

6'-4"

'-0

TY

P

STEEL PIPE PILE, TYP,

SEE NOTE 2

27'-0"

TYP

3'-0"

TYP

31'-0"

'-0

FA

IR

W

A Y

W

ID

TH

12'-0"

6'-0"

8'

-0

24'-0"

'-0

TY

P

9'-8"

6' -0

40'-0"

TYP

50'-0"

TYP

50'-0"

TYP

68'-0"

TYP

6' -0

12'-0"

TYP

220'-0"

ALUMINIUM

FRAMED DOCK, TYP

SECURITY GATE SEE

3'-0"

TYP

'-0

TY

P

'-0

48'-7"±

C-5

A C-5

B C-5

(E) GANGWAY

ABUTMENT

A C-6

NOTES

1. STANDPIPE SYSTEM NOT SHOWN FOR

CLARITY.

2. ADJUST LOCATION OF STEEL PIPE PILES TO

BE A MINIMUM OF 10 FEET AWAY FROM

TIMBER PILE STUBS IF NECESSARY.

A C-7

REINSTALL

GANGWAY AND

RAMP LANDING,

SEE

7' -0

TY

P 8'

-0

TY

P

8' -0

TY

P

1'-0"

TYP

10'-0"

TYP

4'-0"

TYP

7' -0

TY

P

'-0

TY

P

'-0

TY

P

1'-0"

TYP

4'-0"

TYP

11'-6"

TYP

13'-6" 4'-0" 13'-6"

ACC

SLIP

ACC

SLIP

3' -4

'-0

75'-0"

TYP

75'-0"

TYP

29'-0"

TYP

BOAT SLIPS

1. 29 TOTAL BOAT SLIPS IN THE MARINA.

2. PER CBC 11B-235.2, 2 ACCESSIBLE BOAT

SLIPS ARE REQUIRED FOR THIS MARINA.

5'X5'

MANEUVERING

CLEARANCE

4'X4'

MANEUVERING

CLEARANCE

6'-0" CLR

MIN

P1P2P3P4

P5

P6

P7 P8 P9 P10 P11

7' -6

" C

LR

M

IN

C-6

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -5

.d w g D at e:

N ov em be r 1

1:

p m

V1

C-5

D O

C K

A N

D P

IL

E

S E

C

TI

O N

S A

N D

D E

TA

IL

S

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

NOTES

1. LAYOUT AND DIMENSIONS OF FLOATATION UNITS

ARE TO BE DESIGNED BY THE CONTRACTOR TO MEET

LOAD AND FREEBOARD REQUIREMENTS.

2. PILE CAP SHALL HAVE A MINIMUM WALL THICKNESS

OF 1/8". PROVIDE A LAYER OF GEL-COTE

PROTECTION. FASTEN TO THE PILE.

3. UHMW FRAME SHALL BE MONOLITHIC AND CUT TO FIT

THE PILE OPENING AND PILE BASED ON FIELD

CONDITIONS. PROVIDE 1/4" CHAMFER ALONG THE

TOP AND BOTTOM OF UHMW FRAME WHICH

INTERFACES WITH THE PILE SURFACE.

4. SEPARATION TAPE SHALL SEPARATE DISSIMILAR

METALS.

5. ASSUME THAT THE BOTTOM OF THE SAND FILL WILL

BE APPROXIMATELY 12" PAST THE DREDGED

MUDLINE DUE TO SOIL DISPLACEMENT DURING

DRIVING.

2"

WIDTH DIMENSION VARIES

COMPOSITE

LUMBER DECKING

12" CLEAT

1' -6

FB

ALUMINUM

FRAMING

RUB STRIP, ES

FULLY ENCASED

FLOATATION

UNITS, SEE NOTE 1

2"

TYP

WIDTH DIMENSION VARIES

12" CLEAT, ES

DOCK CORNER

BUMPER, ES DECKING

RUB STRIP, ES

ALUMINUM

FRAMING

1' -6

FB

A C-4

SECTION - MAINWALK

SCALE: 1 1/2" = 1'-0"

FULLY ENCASED

FLOATATION

UNITS, SEE NOTE 1

B C-4

SECTION - FINGER DOCK

SCALE: 1 1/2" = 1'-0"

2'-6"

2' -6

INSIDE EDGE OF

UHMW FRAME,

SEE NOTE 3

CL GUIDE PILE =

CL GUIDE PILE

BRACKET

INSIDE EDGE OF

COVER BOARD

POLYMER COVER BOARD

INSIDE EDGE OF L3x3

INCOVER BOARD

FASTENERS, TYP

(TOTAL 12)

DECK

1" ALL AROUND

TYP

1/2" ALL AROUND

TYP

5/8" THICK POLYMER COVER

BOARD ATTACH PILE GUIDE

FRAME WITH SS SCREWS, TYP

1 1/2" THICK UHMW PILE

GUIDE FRAME, TYP

SEE NOTE 3

L3x3x1/4, TYP

BOLT WITH COUNTERBORE

ATTACH UHMW PILE GUIDE

FRAME TO FRAME, TYP

ALUMINUM FRAMING, TYP

DISSIMILAR METALS

SEPARATION TAPE, TYP

SEE NOTE 4

FLUSH

SS FASTENERS SIZE &

SPACING PER DOCK

MANUFACTURER, TYP

STEEL PIPE PILE

TOP OF PILE

EL +13.50'

PILE CAP,

SEE NOTE 2

12" DIA X 3/8" WALL THICKNESS,

STEEL PIPE PILEDREDGED MUDLINE EL

VARIES, -6.00' TO -8.00'

SEE

C

SECTION - STEEL PIPE PILE

SCALE: 1 1/2" = 1'-0"

C

DETAIL

SCALE: 3" = 1'-0"

C-4

PLAN - GUIDE PILE BRACKET

SCALE: 1 1/2" = 1'-0"

0'-6" 0'-0'' 0'-3" 0'-6"

SCALE: 3"=1'-0''

1'-0" 0'-0'' 0'-6" 1'-0"

SCALE: 1 1/2"=1'-0''

RUB STRIP, TYP

PILE TIP

EL -48.00'

TOP OF SAND FILL

EL +9.50'

NOMINAL BOTTOM OF SAND FILL,

SEE NOTE 5

SAND FILL

SAND FILL

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -6

.d w g D at e:

N ov em be r 1

1:

p m

V1

C-6

G A

N G

W A

Y , R

A M

P L

A N

D

IN

G S

E C

TI

O

N A

N D

D E

TA

IL

S

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

NOTES

1. IN THE ELEVATION VIEW, DOCK AND LANDING RAMP

LEGS ARE NOT SHOWN FOR THE HIGHEST

ACCESSIBLE TIDE FOR CLARITY.

(E) ABUTMENT

DECKING OF

(E) GANGWAY

ABUTMENT EL +7.80

(E) 30' GANGWAY

(E) RAMP

LANDING

DOCK

4' -6

HIGHEST ACCESSIBLE TIDE

EL +4.30'

LOWEST ACCESSIBLE TIDE

EL -0.70'

1:12

SLOPE

1:12

SLOPE

SEE , TYP EACH LEG

(E) LANDING

RAMP LEG

(E) PLATE 6x6

DECK BOARD

1/2"Ø x 3" HDG

BOLT WITH NUT &

WASHER, TYP

(E) LANDING

RAMP LEG

(E) PLATE 6x6

1/2"Ø BOLT , TYP

A C-4

ELEVATION - GANGWAY

SCALE: 3/4" = 1'-0"

C-1

DETAIL - LANDING RAMP CONNECTION

SCALE: 6" = 1'-0"

B

SECTION

SCALE: 6" = 1'-0"

B

0'-2" 0'-0'' 0'-2" 0'-4"

SCALE: 6"=1'-0''

2'-0" 0'-0'' 1'-0" 2'-0"

SCALE: 3/4"=1'-0''

116'-0" 0'-0'' 3'-0" 6'-0"

SCALE: 1/4"=1'-0''

4' -0

" C

LR

W

ID

TH

(E) ABUTMENT

'-0

(E

) L O

W E

R L

A N

D

IN

G

4' -0

" C

LR

W

ID

TH

4'-0" CLR

WIDTH

30'-0"

(E) GANGWAY

30'-0"

(E) UPPER RAMP

8'-0"

(E) UPPER LANDING

24'-0"

(E) LOWER RAMP

8'-1"

7' -4

(E

) S

TA

IR

S

4'-0" CLR

WIDTH

4' -0

" C

LR

W

ID

THVARYING

SLOPE

1:12

SLOPE

1:12

SLOPE

FL

A

T S

LO

P

E

FLAT

SLOPE

DOCKS

C-4

DETAIL PLAN - EXISTING GANGWAY AND RAMP

SCALE: 1/4" = 1'-0"

MARINA

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -7

.d w g D at e:

N ov em be r 1

1:

p m

V1

C-7

S E

C U

R

IT

Y G

A

TE

A

B U

TM

E

N T

S E

C

TI

O N

S A

N D

D E

TA

IL

S

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

NOTES

1. VERIFY DIMENSIONS IN FIELD PRIOR TO

FABRICATION. PLACE SECURITY GATE SO THAT THE

EXTENTS ARE FLUSH WITH THE EXISTING ABUTMENT.

2. DECK BOARDS PLACED ON EXISTING ABUTMENT

SHALL BE 6x12 TIMBERS. BOARDS SHALL HAVE A GAP

OF 1/4". CUT BOARDS AS NECESSARY TO FIT AROUND

THE SECURITY GATE OR MOUNT THE GATE ON THE

DECK BOARDS AND ANCHOR TO THE GANGWAY

ABUTMENT.

3. RECESS HEAD OF 3/8" DIAMETER BY 9" LONG

ANCHOR BOLTS IN DECK BOARD SO AS TO NOT

CREATE A TRIPPING HAZARD. INSTALL 4 ANCHORS

ON EACH BOARD WITH 2 ANCHORS ON EITHER END

OF THE BOARD. ADD PLUGS TO SEAL COUNTER-BORE

HOLES.

4. VERIFY THE (E) GANGWAY ATTACHMENT TO THE (E)

ABUTMENT.

5'-0"

'-5

/2

8' -1

4"

6" TY

P

6'-6"

SEE NOTE 1

6"

TYP

1'-2 1/2"1'-1 1/2"

TYP

1'-11"

RECESSED HDPE

SIGN PANEL

SQUARE TUBE

EXPANDED

ALUMINUM

SHEET, TYP

1" INTERMEDIATE

BAR

NUMBER PAD

HANDLE

ANCHOR

BOLT, TYP

FOOTING

PLATE, TYP

GANGWAY ABUTMENT

SURFACE

DECK BOARD,

SEE NOTE 2

6"

4" TY

P

4"

TYP

6"

SQUARE TUBE

INTERMEDIATE BAR, TYP

2'-10 1/2"

4' -0

4"

1 1/2"

TYP

GUARDRAIL

DECK BOARD, TYP

SEE NOTE 2

(E) GANGWAY ABUTMENT

SEE

SEE .

(E) ABUTMENT (E) GANGWAY

2"

TYP

ANCHOR BOLT WITH

RECESSED HEAD, TYP

SEE NOTE 3

DECK BOARD, TYP

SEE NOTE 2

DECK BOARD

SEE NOTE 2

RAIL POST

4" TIMBER LAG

SCREWS, TYP

0'-6" 0'-0'' 0'-3" 0'-6"

SCALE: 3"=1'-0''

1'-0" 0'-0'' 1'-0" 2'-0"

SCALE: 1"=1'-0''

A C-4

ELEVATION - FRONT OF SECURITY GATE

SCALE: 1" = 1'-0"

C-1

B

ELEVATION - SIDE OF SECURITY GATE

SCALE: 1" = 1'-0"

DETAIL - GANGWAY ABUTMENT

SCALE: 1" = 1'-0"

DETAIL - GUARDRAIL CONNECTION

SCALE: 3" = 1'-0"

B

3/8" THREADED ROD @ 12"

GRADE TO MATCH TOP OF

GANGWAY ABUTMENT DECK

MAX SLOPE SHALL BE 1:20

HINGE,

TYP

4"

TYP

(E) GANGWAY

REATTACH

GANGWAY HINGE

EXPANDED

ALUMINUM SHEET

1"

TYP

1'-0 1/2"

TYP BIRD

DETERRENT

SPIKES, TYP

SIDE WALL

SPIKES, TYP

4'-6"

1' -6

1/2" DIA X 12" LONG

ANCHOR BOLT, 2

PER SIDE POST

1/2" DIA X 12" LONG

ANCHOR BOLT, 4 PER

FACE-MOUNTED POST

3/4" DIA THREADED ROD W/

EPOXY GROUT

2'-0" MIN EMBEDMENT

TYP

GANGWAY HINGE

ATTACHMENT FACE

PLATE, SEE NOTE 4

TIMBER BOARD

BEHIND ABUTMENT

3/4" DIA THREADED

ROD, TYP

4"

TYP

EQ EQ

C

GANGWAY PLATE ATTACHMENT

SCALE: 1" = 1'-0"

C

3' -1

"3' -6

3'-0"

DOOR

4"

TYP

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -8

.d w g D at e:

N ov em be r 1

1:

p m

V1

C-8

S E

D

IM

E N

T S

TO

R

A G

E S

IT

E

D E

TA

IL

S

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

131'-0" 0'-0'' 0'-6" 1'-0"

SCALE: 1 1/2"=1'-0''

4'-0" 0'-0'' 4'-0" 8'-0"

SCALE: 1/4"=1'-0''

1' -0

" E M

B E

D M

E N

T M

IN

1"X1"X24" STAKE

@ 48" MAX, TYP

2" MIN

4" MAX

8" DIA STRAW WATTLE, TYP

DREDGE MATERIAL

AT STORAGE SITE.

SEE NOTE 1

EG

G-5

DETAIL - SEDIMENT STORAGE SITE EROSION CONTROL

SCALE: 1 1/2" = 1'-0"

NOTES

1. SLOPE DREDGED MATERIAL TO DRAIN. THE HEIGHT

OF THE DREDGED MATERIAL SHALL BE 3 FEET

MAXIMUM ABOVE EG.

1:2

MAX SLOPE

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -9

.d w g D at e:

N ov em be r 1

1:

p m

V1

C-9

S E

C U

R

IT

Y C

A M

E R

A A

N D

L U

M

IN

A

IR

E D

E

TA

IL

S

11-17-2026

J. ESTRADA

PH, EP, JE

R. DORNHELM

140'-6" 0'-0'' 0'-3" 0'-6"

SCALE: 3" = 1'-0''

C-1

CAMERA DETAIL

SCALE: 3" = 1'-0"

REPLACEMENT

LED LUMINAIRE,

SEE NOTE 3

(E) SQUARE STEEL LIGHT POLE, SEE

CAMERA,

SEE NOTE 1 15

'-0

M O

U N

T H

E

IG

H T

POTENTIAL ROUTER

FOR CAMERA

NOTES

1. INSTALL CAMERA TO FACE TOWARDS DOCKS.

2. DIAMETER AND LENGTH OF SELF DRILLING

SCREWS SHALL BE PER THE CAMERA

MANUFACTURER'S RECOMMENDATIONS.

3. DEMOLISH AND DISPOSE OF THE EXISTING

LUMINAIRE ON LIGHT POLE. THE REPLACEMENT

LED LUMINAIRE SHALL BE UBIU-9001-42W AS

SUPPLIED BY LIGMAN LIGHTING, OR APPROVED

EQUAL.

LIGHT POLE PHOTO

SCALE: NTS

EG

SELF DRILLING SS SCREWS WITH

HEX HEAD, SEE NOTE 2

X X

X

XXXXXX

X

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -1

0.

dw g D at e:

N ov em be r 1

1:

p m

10-23-2026

NOTES

1. THE EXTENT OF THE CONCRETE PAD

SHALL INCLUDE THE ACCESSIBLE

PARKING STALL AND ACCESS AISLE

INCLUDING THE STRIPING. DEMOLISH

AND DISPOSE OF THE EXISTING AC, AB,

AND SUBGRADE AS NEEDED TO F&I THE

CONCRETE PAD.

2. SAWCUT 1' FROM THE EDGE OF THE

CONCRETE PAD, PAVE NEW ASPHALT TO

THE EXISTING GRADE SO THAT A SLOPE

OF 2% IS NOT EXCEEDED. THE

INTERFACE BETWEEN THE EXISTING AND

NEW ASPHALT SHALL BE FOG SEALED.

3. FOG SEAL EXISTING STRIPING PRIOR TO

NEW STRIPING.

4. SCARIFY THE NATIVE SUBGRADE 4" IN

DEPTH AND RECOMPACT AT 95%

RELATIVE COMPACTION.

TYPICAL PARKING SPACES

SCALE: NTS

ISA MARKING

(TYP), SEE CSP

A90A

4" BLUE

LINE

BORDERS

SIGN R99C & R7-8B SEE

4" WHITE

LINE, TYP

9'

TYPICAL STANDARD

PARKING SPACE

NO

PARKING

12" HIGH

WHITE

LETTERS

(E) CURB

8'9'

SIGN (R100B) STANDARD

18" X 24"

ACCESSIBLE PARKING ONLY MINIMUM

FINE $250 (R99C)

STANDARD 12" X 24"

12" DIA X 24"

DEEP CONCRETE

FOOTING

5'- 0"

(R

0B

6'- 8"

(R

C W

/ R 7-

8B

2" DIAMETER

GALVANIZED

STEEL PIPE

2-1/2" DIAMETER

GALVANIZED STEEL

PIPE SLEEVE

INSTALL

SIGN(S)

3/8" DIAMETER

BOLT/NUT THROUGH

1/2" DIAMETER DRILLED

HOLE

1- 1/

2"

3" 6"

UNAUTHORIZED VEHICLES PARKED IN

DESIGNATED ACCESSIBLE SPACES NOT

DISPLAYING DISTINGUISHING PLACARDS OR

SPECIAL LICENSE PLATES ISSUED FOR

PERSONS WITH DISABILITIES WILL BE

TOWED AWAY AT OWNER'S EXPENSE

TOWED VEHICLES MAY BE

RECLAIMED BY TELEPHONING

(XXX) XXX-XXXX*

SIGN POST

* INFORMATION TO BE

PROVIDED BY THE OWNER

VAN-ACCESSIBLE PARKING

(R7-8B) 12" X 6"

VAN-ACCESSIBLE

PARKING SPACE

4" WHITE LINE

DIAGONALS, TYP

PARKING SIGNS

SCALE: NTS

SIGN R100B SEE 3

C-10

PA

RK

IN

G

LO

T

DE

TA

IL

S

11-17-2026

J. ESTRADA

JE

R. DORNHELM

DPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -1

0.

dw g D at e:

N ov em be r 1

1:

p m

V1

(E) CURB, TYP

EDGE OF

PAVEMENT

1'

SAWCUT, SEE NOTE 2

CONC PAD FOR ACC PARKING

STALL AND ACCESS AISLE, SEE

NOTE 1

(E) CURB, TYP

STRIPING FOR

PARKING STALL, TYP

SEE NOTE 3 &

PARKING SIGN(E) LIGHT POLE

(E) FENCE

STRIPING FOR ACC PARKING

STALL AND ACCESS AISLE, TYP

SEE

C-1

DETAIL PLAN - PARKING AREA

SCALE: 1" = 10'

A

(E) AC

#4 @ 12" EW, TYP

6" C

O N

C 6"

A B

FLUSH

A

SECTION - CONCRETE PAVING

SCALE: 3" = 1'-0"

-10' 0' 10' 20'

1" = 10'

0'-6" 0'-0'' 0'-3" 0'-6"

SCALE: 3" = 1'-0''

3'

3' PARTIAL DEMO OF

(E) CURB

PARTIAL (E) CURB DEMO

DEMO (E) ISA SIGN

(E) SIGN

3" A

C 9"

A B

SAWCUT 1'

EL 25.56'

EL 25.31'

EL 25.23'EL 25.45'

SUBGRADE, SEE NOTE 4

LEGEND

AC

AB

CONC

CURB DEMO

ELEVATION POINT

27.43'

26.79'

26.35'

25.18'

24.06'

23.19'

22.49' 21.86' 21.04'

20.80'

20.70'

20.69'

20.84'

20.86'

20.34'

19.87'

19.11' 16.03'

13.10'

11.76'

11.31'

11.68'

-2 .0

-1

.5

-2 .9

-3 .8

-2.

6%

-2.3%

-2.0% -2.0% -0.7%

-0 .3

-0

.0 % 0.3%

0.3%

-3.1%

-2 .7

-4.2%

-4.5%

-4.5%

-4.3%

-2.

9%

1.

2%

X X

X X

X X

X X

X X

X

XX

X

X X

X X

PROJECT CONTROL

WORK POINT NORTHING EASTING

WP9 1803894.23 6650694.58

WP10 1803885.83 6650702.90

WP11 1803930.30 6650736.58

WP12 1803889.63 6650970.51

WP13 1803869.99 6650975.61

WP14 1803894.66 6650798.15

WP15 1803897.16 6650784.64

WP16 1803890.00 6650792.35

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -1

1.

dw g D at e:

N ov em be r 1

1:

p m

10-23-2026

NOTES

1. THE MARINA DOCKS, GANGWAY,

SECURITY GATE, AND LANDING ARE NOT

SHOWN FOR CLARITY.

2. FEATURES SHOWN ON THIS SHEET ARE

BASED ON A SURVEY PERFORMED ON

10/12/2026 BY JAMES DICKEY.

3. PROTECT EXISTING SITE FEATURES NOT

CALLED TO BE DEMOLISHED.

4. DEMOLISH AND DISPOSE OF THE

EXISTING ASPHALT AND AGGREGATE

BASE, ASSUMED TO BE 2" OF AC OVER 1"

OF AB, FOR THE WALKWAY AND REPLACE

WITH THE NEW SECTION. ENSURE THAT

THE MAXIMUM LONGITUDINAL SLOPE IS

4.5%. APPROXIMATELY 5100 SF.

5. LANDINGS SHALL HAVE A MAXIMUM OF

LONGITUDINAL AND CROSS SLOPE OF

1.5%.

6. SCARIFY THE NATIVE SUBGRADE 4" IN

DEPTH AND RECOMPACT AT 95%

RELATIVE COMPACTION.

7. CROSS SLOPE TO SLOPE TOWARDS THE

MARINA BASIN.

8. CLEAR AND GRUB VEGETATION BETWEEN

WALKWAY AND TIMBER RETAINING WALL.

C-11

PA

TH

R

EP

AV

IN

G

11-17-2026

J. ESTRADA

JE

R. DORNHELM

DPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

C -1

1.

dw g D at e:

N ov em be r 1

1:

p m

V1

(E) CABIN

C-1

REPLACEMENT ASPHALT PLAN

SCALE: 1" = 20'

B

-20' 0' 20' 40'

1" = 20'

1'-0" 0'-0'' 0'-6" 1'-0"

SCALE: 1 1/2" = 1'-0''

LEGEND

AC

AB

CONC

LANDING LIMITS

ELEVATION POINT

WORK POINT

(E) ELECTRIC BOX

(E) BENCH ON

CONC PAD

(E) LIGHT POLE

(E) CURB, TYP

ACC PARKING

PARKING

STRIPING

(E) FENCE

(E) BLOCK

RETAINING WALL

(E) TIMBER

RETAINING WALL, SEE

(E) TIMBER

POST

(E) CONC

ABUTMENT

REPLACEMENT

AC, SEE NOTE 4

A

A

PAVED WALKWAY DEMOLITION

SCALE: 1 1/2" = 1'-0"

B

PAVED WALKWAY

SCALE: 1 1/2" = 1'-0"

(E) WALKWAY TO BE

REPLACED, SEE NOTE 4

WIDTH VARIES

2"

AC

4" A B

WALKWAY

10' FOR UPPER WALKWAY

5' FOR LOWER WALKWAY

WP9

WP10

WP11

WP12

(E) TIMBER

POST

(E) AC

(E) SIGN

(E) METER (E) BARBECUE

(E) PICNIC

TABLE

(E) HOSE

BIBB

SUBGRADE, SEE NOTE 6

TOE OF BANK

TOP OF BANK

TOP OF BANK

TOP OF BANK

TOP OF

BANK

6"

EXCAVATION

TIMBER RETAINING WALL PHOTO

SCALE: NTS

(E) WALKWAY

(E) TIMBER

RETAINING WALL,

PROTECT IN PLACE

CLEAR AND GRUB

VEGETATION

BETWEEN WALKWAY

AND TIMBER

RETAINING WALL, SEE C

0'-6" 0'-0'' 0'-3" 0'-6"

SCALE: 3" = 1'-0''

C

CLEARING AND GRUBBING

SCALE: 3" = 1'-0"

WALKWAY

(E) TIMBER

RETAINING

WALL, PROTECT

IN PLACE

WIDTH VARIES

CLEAR AND GRUB, SEE NOTE 8

WP13

WP14

WP15 WP16

(E) AC

UPPER

WALKWAY

LOWER

WALKWAY

CL ELEVATION PER PLAN

1.5% TYP / 2.0% MAX

CROSS SLOPE, SEE NOTE 7

LANDING,

SEE NOTE 5

LANDING,

SEE NOTE 5

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

M -1

.d w g D at e:

N ov em be r 1

1:

p m

V1

ABBREVIATIONS

M-1

M E

C H

A N

IC

A

L G

E N

E R

A L

N O

TE

S

A N

D A

B B

R E

V

IA

TI

O

N S

11-17-2026

J. FERNANEZ

JF

A. KONYALIAN

MECHANICAL NOTES:

1. FIRE PROTECTION PLANS MUST BE APPROVED BY THE AHJ PRIOR

TO THE INSTALLATION OF ANY PIPE. DURING CONSTRUCTION, A SET OF

APPROVED PLANS MUST BE MAINTAINED AT ALL TIMES ON THE JOB

SITE.

2. COMPLETED WORK MUST BE SUBJECTED TO A FIRE WATER

PRESSURE TEST OF 200 PSI FOR 2 HOURS, DURING WHICH THERE IS TO

BE NO REDUCTION IN TEST PRESSURE. IF A REDUCTION SHOULD

OCCUR, LEAK(S) MUST BE LOCATED, REPAIRED AND THE TEST

REPEATED. IN ADDITION, ALL NEWLY INSTALLED FIRE SERVICE LINES

MUST PASS HYDROSTATIC AND HYDRODYNAMIC TESTING

REQUIREMENTS AS PERFORMED BY THE LOCAL FIRE MARSHAL.

3. THE SYSTEM MUST ONLY EMPLOY THE USE OF APPROVED

MATERIALS AND DEVICES OF NO LESS THAN 200 PSI RATED WORKING

PRESSURE. NEW MARINA FIRE WATER PIPING MUST BE HDPE DR 9

UNLESS NOTED OTHERWISE. PLASTIC PIPING MAY BE USED IN AREAS

WHERE IT IS NOT EXPOSED TO FIRE, OTHERWISE STAINLESS STEEL

PIPING MUST BE USED.

4. PIPING MATERIAL & FIREWATER SYSTEM MUST BE IN

COMPLIANCE WITH LATEST VERSIONS OF: NFPA 14, SACRAMENTO FIRE

CODE, CALIFORNIA FIRE CODE, AND REQUIREMENTS OF AUTHORITY

HAVING JURISDICTION. ALL MATERIALS MUST BE UL LISTED WHERE

AVAILABLE.

5. FLOAT FIRE PROTECTION SYSTEMS SHALL BE PROVIDED PER THE

2022 CALIFORNIA FIRE CODE.

6. FLOAT FIRE PROTECTION SYSTEM SHALL CONSIST OF A CLASS I

MANUAL DRY STANDPIPE HOSE CONNECTION SYSTEM, PER NFPA 14

AND NFPA 303. HOSE CONNECTIONS SHALL BE PROVIDED SUCH THAT

EVERY PORTION OF THE FLOAT IS WITHIN 150 FEET OF A 2-1/2" INCH

CLASS I HOSE CONNECTION. HOSE CONNECTIONS SHALL HAVE

NATIONAL STANDARD HOSE THREADS AND CAP.

7. THE STANDPIPE SYSTEM MUST BE CAPABLE OF SUPPLYING A

FLOW OF 500 GPM TO THE HYDRAULICALLY MOST REMOTE STANDPIPE

CONNECTION AND 250 GPM FOR EACH ADDITIONAL STANDPIPE.

8. EACH STANDPIPE OUTLET SHALL BE PLACED TO PROVIDE A

MINIMUM OF 6 INCHES ON ALL SIDES OF THE HANDLE AND 18 INCHES

ON ALL SIDES OF THE OUTLET OR LOCATED AS APPROVED BY THE FIRE

CODE OFFICIAL.

9. THE CONTRACTOR SHALL VERIFY ALL CONTROLLING FIELD

DIMENSIONS BEFORE ORDERING OR FABRICATING ANY MATERIAL.

ABC ASSOCIATED BUILDERS AND CONTRACTORS

ACC ACCESSIBLE

AHJ AUTHORITY HAVING JURISDICTION

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

BV BALL VALVE

BFP BACKFLOW PREVENTION DEVICE

CHV CHECK VALVE

CSLB CONTRACTORS LICENSE BOARD

CU COPPER

DIA DIAMETER

DR DIMENSION RATIO

DWG DRAWING

(E) EXISTING

ELL ELBOW

F FIRE WATER

FDC FIRE DEPARTMENT CONNECTION

FEC FIRE EXTINGUISHER CABINET

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FWHC FIRE WATER HOSE CONNECTION

GPM GALLONS PER MINUTE

GV GATE VALVE

GV GATE VALVE IN VALVE BOX & COVER

HDPE HIGH DENSITY POLYETHYLENE

HB HOSE BIBB

IPS IRON PIPE SIZE

ISO ISOLATION

LED LIGHT EMITTING DIODE

MFR MANUFACTURER

MLW MEAN LOW WATER

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NPT NATIONAL PIPE THREAD

NSF NATIONAL SANITATION FOUNDATION INTERNATIONAL

OC ON CENTER

PEX CROSS-LINKED POLYETHYLENE

POC POINT OF CONNECTION

PPM PARTS PER MILLION

PVC POLYVINYL CHLORIDE PIPE

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH GAUGE

RED REDUCER

SFFC SAN FRANCISCO FIRE CODE

SFFD SAN FRANCISCO FIRE DEPARTMENT

SS STAINLESS STEEL

STD STANDARD

TYP TYPICAL

UL UNDERWRITERS LABORATORIES, INC.

UNO UNLESS NOTED OTHERWISE

UP POWER PEDESTAL W/ HOSE BIBB

VIC VICTAULIC

W POTABLE WATER

W/ WITH

WL WATER LEVEL

1. CONTRACTOR SHALL HAVE A CSLB TYPE C-16 LICENSE,

REQUIRED FOR THE INSTALLATION OF THE FIRE PROTECTION SYSTEM.

SHOP DRAWINGS SHALL BE STAMPED BY A LICENSED C-16 FIRE

PROTECTION CONTRACTOR.

2. INSTALLATION OF PIPING SYSTEMS, INCLUDING COORDINATION

WITH OTHER TRADES, MUST BE COORDINATED WITH THE WATER, FIRE

AND OTHER AHJ DEPARTMENTS. PRIOR APPROVAL OF AND NOTICE TO

PROCEED WITH THE TIE-INS TO EXISTING UTILITIES ARE REQUIRED BY

THE LOCAL AHJ FOR THE WATER SYSTEM. AUTHORIZED

REPRESENTATIVE MUST WITNESS TIE-IN, AS REQUIRED.

3. ALL PIPING MUST FOLLOW THE GENERAL ARRANGEMENT

SHOWN. PIPING MUST BE RUN AS INDICATED, CARE BEING TAKEN TO

AVOID INTERFERENCE WITH OTHER PIPING, CONDUIT, OR EQUIPMENT.

THE LOCATION OF PIPING TO BE RUN ON THE DOCK MUST BE

COORDINATED WITH ELECTRICAL CONDUITS SPECIFIED. BEFORE

JOINTING AND ERECTION OF PIPING, THOROUGHLY CLEAN INTERIORS

OF PIPE AND COMPONENTS. MAINTAIN CLEANLINESS BY CLOSURE OF

PIPE OPENINGS WITH CAPS OR PLUGS.

4. OBTAIN ALL REQUIRED BUILDING/TRADE PERMITS AND PROVIDE

ALL REQUIRED TESTING.

5. ENSURE SUFFICIENT PIPE FLEXIBILITY AND ANCHORAGE IS

PROVIDED FOR ALL LINES FOR THERMAL EXPANSION AND

CONTRACTION, AND PRESSURE. THE DOCK STRUCTURE AND

COMPONENTS MUST ACCOMMODATE THE PIPING LAYOUT

REQUIREMENTS SUCH THAT THE PIPE MUST NOT BECOME

OVERSTRESSED. THE PIPING MUST BE PROPERLY SUPPORTED AND

ANCHORED.

6. INSPECT MATERIALS DELIVERED TO SITE FOR DAMAGE. UNLOAD

AND STORE WITH MINIMUM HANDLING. STORE MATERIALS ON SITE IN

ENCLOSURES OR UNDER PROTECTIVE COVERING. STORE PLASTIC

PIPING UNDER COVER OUT OF DIRECT SUNLIGHT. DO NOT STORE

MATERIALS DIRECTLY ON THE GROUND. KEEP INSIDE OF PIPES,

FITTINGS AND EQUIPMENT FREE OF DIRT AND DEBRIS. HANDLE PIPE,

FITTINGS, VALVES, AND OTHER ACCESSORIES IN SUCH MANNER AS TO

ENSURE DELIVERY TO THE INSTALLATION LOCATION IN A SOUND

UNDAMAGED CONDITION.

7. FURNISH ALL FIRE WATER MATERIALS (PIPE, VALVES, ETC.). ALL

SUCH MATERIALS MUST BE NEW, MEET DISTRICT, COUNTY, WATER

UTILITY COMPANY AND OTHER AHJ SPECIFICATION REQUIREMENTS

FOR EACH ITEM. PRIOR TO INSTALLATION, MATERIALS MUST BE

APPROVED IN WRITING BY THE ENGINEER AND AHJ.

8. SHOULD THERE BE A CONFLICT BETWEEN THESE GENERAL

NOTES, CONTRACT DRAWINGS, AND/OR CONTRACT DOCUMENTS, THE

MOST RESTRICTIVE INTERPRETATION MUST PREVAIL. THE

CONTRACTOR MUST BE RESPONSIBLE FOR OBTAINING FROM THE

ENGINEER ANY CLARIFICATION OR INTERPRETATION OF GENERAL

NOTES, CONTRACT DRAWINGS, AND/OR SPECIFICATIONS IN WRITING

AND IN ADVANCE OF THE BEGINNING OF CONSTRUCTION.

9. LOCATIONS OF UTILITIES, PUBLIC AND/OR PRIVATE, ARE

APPROXIMATE ONLY, AND THE EXACT LOCATIONS MUST BE

DETERMINED IN THE FIELD. IT IS POSSIBLE THAT SOME EXISTING

FACILITIES ARE NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR

MUST BE RESPONSIBLE FOR HAVING ALL EXISTING UTILITIES

RELEVANT TO PROJECT CONSTRUCTION LOCATED AND MARKED PRIOR

TO THE BEGINNING OF CONSTRUCTION.

10. PROVIDE ALL NECESSARY PROTECTIVE MEASURES TO PROTECT

EXISTING UTILITIES FROM DAMAGE DURING CONSTRUCTION OF THIS

PROJECT. SHOULD SPECIAL EQUIPMENT BE REQUIRED TO WORK OVER

AND AROUND THE UTILITIES, THE CONTRACTOR MUST BE REQUIRED

TO FURNISH SUCH EQUIPMENT. THE COST OF PROTECTING UTILITIES

FROM DAMAGE AND FOR FURNISHING SPECIAL EQUIPMENT MUST BE

INCLUDED IN THE BID FOR CONSTRUCTION.

11. CONTACT ALL AFFECTED UTILITY OWNERS PRIOR TO SUBMITTING

A BID TO COORDINATE SCHEDULING OF WORK FOR THE PROJECT. THE

CONTRACTOR MUST RECEIVE NO ADDITIONAL COMPENSATION FOR

ANY DELAYS OR INCONVENIENCE CAUSED BY NECESSARY UTILITY

COMPANY ADJUSTMENTS TO THE PROJECT SCHEDULE.

12. SUPPORTS AND HARDWARE SHALL BE TYPE 316 STAINLESS

STEEL. FIELD BENDING IS NOT PERMITTED. VALVE SUPPORTS SHALL BE

INSTALLED ON ADJACENT PIPING ON BOTH SIDES OF THE VALVE.

SUBMIT SHOP DRAWINGS OR CATALOG DATA FOR REVIEW AND

APPROVAL. A DIELECTRIC ISOLATION SHEET SHALL BE PLACED WHERE

DISSIMILAR METALS CONTACT ON THE SUPPORT.

13. ALL UNSUITABLE MATERIAL, AS DETERMINED BY THE ENGINEER,

OR THROUGH TESTING, SHALL BE REMOVED, LEGALLY DISPOSED, AND

REPLACED WITH SUITABLE MATERIAL, WITH CORRESPONDING

CLOSURE REPORT(S), AND ACCEPTABLE TO THE ENGINEER AND

REGULATORY AUTHORITIES.

14. DIELECTRIC COUPLINGS SHALL BE USED AT DISSIMILAR METAL

PIPING CONNECTIONS.

15. PROVIDE TEMPORARY BLOW OFF VALVES AT THE END OF EACH

WATER/FIRE LINE. DRAIN CONNECTIONS SHALL BE PROVIDED AT LOW

POINTS FOR WATER AND FIRE SYSTEMS.

FIRE WATER SYSTEM NOTES:

X

X X

X X

X X

X X

X X

X

X

X

X

X

X

DPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

M -2

.d w g D at e:

N ov em be r 1

1:

p m

V1

M-2

FI

R

E P

R O

TE

C

TI

O

N S

IT

E

P

LA

N

11-17-2026

J. FERNANDEZ

JF

A. KONYALIAN

CURB, TYP

-20' 0' 20' 40'

1" = 20'

FIRE PROTECTION SITE PLAN

SCALE: 1" = 20'

(E) PARKING AREA

SEE SHEET M-3 FOR DOCK FIRE WATER PLAN

SEE 2

M-5

FIRE HYDRANT. TO

BE PROVIDED BY

OTHERS.

FDC

3' MIN. SEE

NOTE 2

SEE NOTE 1

NOTES

1. DECONSTRUCT STACKABLE MASONRY UNIT

RETAINING WALL FOR FIRE LINE

INSTALLATION IN A MANNER WHICH

PRESERVES MASONRY UNIT BLOCK FOR

REINSTALLATION.

2. PROVIDE 3' MINIMUM CLEARANCE FROM

EDGE OF PAVEMENT FOR FIRE LINE

INSTALLATION.

SEE 3

M-5

0+

.0

0+

.0

0+

.0

0+

.0

1+00.00 1+25.00 1+42.75

6.37'±

PILE COORDINATES

PILE NUMBER NORTHING EASTING

P1 1803706.83 6650950.28

P2 1803759.85 6650907.69

P3 1803798.83 6650876.38

P4 1803837.81 6650845.07

P5 1803862.92 6650810.54

P6 1803829.11 6650768.44

P7 1803791.13 6650721.09

P8 1803756.16 6650743.41

P9 1803717.17 6650774.72

P10 1803678.19 6650806.03

P11 1803625.17 6650848.61

DPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

M -3

.d w g D at e:

N ov em be r 1

1:

p m

V1

M-3

D O

C K

F

IR

E W

A

TE

R P

LA

N

11-17-2026

J. FERNANDEZ

JF

AK

MHHW

MLLW

C-1

DOCK FIRE WATER PLAN

SCALE: 1" = 10'

10'-0" 0'-0'' 10'-0" 20'-0"

SCALE: 1''=10'

LEGEND

WORK POINT

FIRE EXTINGUISHER CABINET

(FEC) ( TOTAL 7 )

(E) GANGWAY

ABUTMENT

A M-4

NOTES

1. FIRE HOSE STANDPIPES ARE SPACED PER

NFPA 14 REQUIREMENTS FOR MARINAS.

CONTRACTOR IS RESPONSIBLE FOR

SUBMITTING SHOP DRAWINGS

DEMONSTRATING THE PROPOSED

DIMENSIONS OF INSTALLATION SUBJECT TO

REVIEW AND CONFIRMATION.

2. PIPE ROUTING SHALL BE INSTALLED AS TO

AVOID CONTACT WITH PILES.

ACC

SLIP

ACC

SLIP

104'-7"

104'-7"

5'-11"

4" HDPE SDR9 PIPE

4" HDPE SDR9 PIPE

6" HDPE SDR9 PIPE

STANDPIPE RISER W/

FIRE EXTINGUISHER

6" PVC DR 21 PIPE

6" X 4" HDPE IPS BUTT

REDUCER (TYP)

STANDPIPE RISER W/

FIRE EXTINGUISHER

STANDPIPE RISER

STANDPIPE RISER

SEE 1

M-5

75'-0" (TYP)

P1P2P3P4

P5

P6

P8 P9 P10 P11

P7

6" HDPE IPS BUTT 45°

ELBOW (TYP)

36'-0"

36'-0"

9' -8

6' -9

3'-5"

4'-0"

8'

-8

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

M -4

.d w g D at e:

N ov em be r 1

1:

p m

V1

M-4

FI

R

E P

R O

TE

C

TI

O

N E

LE

V

A

TI

O N

S

11-17-2026

J. FERNANDEZ

JF

AK

NOTES

1. IN THE ELEVATION VIEW, DOCK AND LANDING RAMP

LEGS ARE NOT SHOWN FOR THE HIGHEST

ACCESSIBLE TIDE FOR CLARITY.

(E) ABUTMENT

DECKING OF

(E) GANGWAY

ABUTMENT EL +7.80

(E) GANGWAY

(E) RAMP

LANDING

DOCK

HIGHEST ACCESSIBLE TIDE

EL +4.30'

LOWEST ACCESSIBLE TIDE

EL -0.70'

1:12

SLOPE

1:12

SLOPE

A M-3

ELEVATION - GANGWAY PIPE CONNECTION

SCALE: 3/4" = 1'-0"

C-1

2'-0" 0'-0'' 1'-0" 2'-0"

SCALE: 3/4"=1'-0''

6" CORRUGATED

DOUBLE BRAIDED

METAL HOSE. 5'

LIVE LENGTH W/

25" MIN BEND

RADIUS.

6" 316 SS SCH 40

PIPE

6" CORRUGATED

DOUBLE BRAIDED

METAL HOSE.

9-1/2' LIVE

LENGTH W/ 25"

MIN BEND RADIUS

SS RIGID

COUPLING (TYP)

6" PVC DR 21 PIPE

TO FDC. ON

FARSIDE

6" LONG RADIUS

316 SS SCH 40

ELBOW (TYP)

6" HDPE SDR 9 PIPE

TO FLOATING DOCK

6" HDPE-TO-STEEL

GROOVED TRANSITION

COUPLING

6" PVC-TO-STEEL

GROOVED TRANSITION

COUPLING

SUPPORTS SHALL

BE SPACED A

MAXIMUM OF 15

FEET

5' -0

" M A

X

2' -7

1'

-6 " M

IN

FDC

CLASS I STANDPIPE

BRANNAN ISLAND MARINA

DPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

M -5

.d w g D at e:

N ov em be r 1

1:

p m

V1

M-5

FI

R

E P

R O

TE

C

TI

O

N D

E

TA

IL

S

11-17-2026

J. FERNANDEZ

JF

AK

NOTES

1. THRUST BLOCK SHOWN IN DETAIL 2 IS SCHEMATIC

ONLY. PROVIDE CONCRETE THRUST BLOCK PER

(2024) NFPA 24 & (2022) CALIFORNIA PLUMBING CODE.

THE CONTRACTOR SHALL SUBMIT THRUST BLOCK

DESIGN CALCULATIONS TO THE AUTHORITY HAVING

JURISDICTION FOR REVIEW AND APPROVAL PRIOR TO

CONSTRUCTION.

2. FOR STANDPIPE RISERS ON THE 6" HDPE SDR9 FIRE

MAIN USE A 6" X 3" HDPE IPS BUTT REDUCER. ADJUST

BRACKET TYPE / SPACING AS REQUIRED TO

ACCOMMODATE PIPE SIZE.

M-3

DETAIL - STANDPIPE AND FIRE EXTINGUISHER CABINET

SCALE: 1" = 1'-0"

2-1/2" ANGLE BRASS

VALVE HOSE

CONNECTION (175 PSI

MIN. RATING)

STANDPIPE HOSE

OUTLET LOCKING CAP

1' -6

" M

IN

PROVIDE MIN. 18"

CLEARANCE ON ALL

SIDES OF THE HOSE

OUTLET

DRY CHEMICAL FIRE

EXTINGUISHER &

CABINET

2-1/2" 316 SS RISER

STEEL BRACKET

1'-0" 0'-0'' 1'-0" 2'-0"

SCALE: 1"=1'-0''

2-1/2" 316 SS GROOVED

RIGID COUPLING

3" X 2-1/2" 316 SS

GROOVED CONCENTRIC

REDUCER

3" 316 SS GROOVED

RIGID COUPLING

3" 316 SS RISER

3" HDPE-TO-STEEL

GROOVED TRANSITION

COUPLING

4" X 3" HDPE IPS BUTT

REDUCER, SEE NOTE 2

4" HDPE SDR9 FIRE WATER

MAIN, SEE NOTE 2

FREE STANDING 3-WAY

FIRE DEPT. INLET

CONNECTION 6" X 2-1/2"

X 2-1/2" X 2-1/2"

FDC LOCKING CAP

6" 3'

M

IN

. D E

P

TH

O F

B U

R Y

T O

F

FS

6" SPOOL

3' X 3' CONCRETE

FOUNDATION

#4 REBAR

CONCRETE THRUST

BLOCK

" T

O

8"

SIGN IDENTIFYING TYPE

OF SYSTEM AND AREA

SERVED. SIGN SHALL BE

MOUNTED ON THE FDC

SPOOL / RISER

M-2

DETAIL - FIRE DEPARTMENT CONNECTION

SCALE: N.T.S.

SEE NOTE 2 FOR 6"

MAIN

SEE PLAN FOR LOCATIONS

THAT INCLUDE FIRE

EXTINGUISHER

M-2

DETAIL - FIRE WATER TRENCH

SCALE: 1-1/2" = 1'-0"

WARNING TAPE

6"Ø PVC DR 21 PIPE

PEA GRAVEL

95% SAND PROCTOR

85% BACKFILL

PROCTOR

6"

6" 9"

9"

3' -0

" M

IN

E le va tio n

-0+05 0+00 0+25 0+50 0+75

S

TA

+0

6"

E

LB

O

W C

O N

N E

C T

TO

H

O R

IZ

O

N

TA

L P

IP

E

A N

D 6"

°E

LB

O W

T O

F D

C R

IS

E

R . S

E E

P

LA

N O

N S

H E

E T

M -2

S

TA

+7

6.

6"

E

LB

O W

IN

V

7.

E le va tio n

1+00 1+25 1+47

S

TA

+8

5.

6"

.5

0° E

LB

O

W

IN

V

7.

S

TA

+9

1.

6"

.5

0° E

LB

O

W

IN

V

5.

S

TA

+9

9.

6"

.5

0° E

LB

O

W

IN

V

5.

S

TA

+2

6.

6"

.5

0° E

LB

O

W

IN

V

.4

S

TA

+3

5.

6"

E

LB

O W

IN

V

.2

S

TA

+3

6.

6"

E

LB

O W

IN

V

.4

S

TA

+4

2.

6"

E

LB

O W

IN

V

.6

E le va tio n

-0+05

E le va tio n

1+47

Station

Station

DPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

SHEET NO.

OF

DRAWN:

REVISIONS

CHECKED:

DATE

DESIGNED:

DATE:

ACCESSIBILITY COMPLIANCE AND STATE FIRE

MARSHAL SIGNED ORIGINALS ARE ON FILE AT THE

DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

CERTIFICATION #

Reviewed by Date

FACILITIES AND

DEVELOPMENT DIVISION

PROJECT MILESTONE: 100%

207833.

B R

A N

N A

N

IS

LA

N

D M

A R

IN

A

R E

S

TO

R A

TI

O

N B

R A

N N

A N

IS

LA

N D

S

TA

TE

P

A R

K

Fi le

: P :\W

C \9

0-n3 br an no n is la nd \2

C

A D

D

A ct iv e\

_s he et se t\9

0N

M -6

.d w g D at e:

N ov em be r 1

1:

p m

V1

M-6

FI

R

E W

A

TE

R P

R O

FI

LE

11-17-2026

J. FERNANDEZ

JF

AK

M-2

FIRE WATER PROFILE 1

SCALE: 1" = 5'

EXISTING GRADE

M-2

FIRE WATER PROFILE 2

SCALE: 1" = 5'

5' 0' 5' 10'

SCAL…

This is the start of the file's text. The full file is on GovTribe.