Drawings 18414_Part1.pdf
PDF 5 MB Posted
- Solicitation number
- RFQ-171-190000000413-3
- Issued by
- Barry County, Michigan
About this file
This is a set of mechanical drawings issued by the State of Michigan Department of Technology, Management and Budget, Facilities and Business Services Administration, Design and Construction Division for a deaerator replacement project at the Lakeland Correctional Facility in Coldwater, MI. The project involves replacing existing deaerator equipment and associated piping systems in the facility's boiler plant, including installation of a new reverse osmosis system with carbon filter, storage tank, and booster pump. The drawings show detailed demolition and new installation plans for the basement, first floor, lower mezzanine and upper mezzanine levels, with work to be conducted during specified hours of 6:30 AM - 3 PM.
The project requires maintaining boiler system operation throughout construction, with temporary shutdowns limited to 7 hours maximum between 9 PM - 4 AM and requiring 72-hour advance notice. Matrix Consulting Engineers is serving as the mechanical/electrical engineer. Special requirements include contractor responsibility for asbestos/lead abatement, roof penetration patching to maintain warranties, and coordination with Slatile Roofing. The drawings include detailed specifications for the reverse osmosis system components and integration with existing steam and condensate systems. The project file number is 472/18414.SMD with funding code 472LCFMaintProj.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Addendum 2.pdf | ||
| Advertisement 18414.pdf | ||
| Specifications 18414 (S).pdf | ||
| LEIN Request 18414.pdf | ||
| Drawings 18414_Part2.pdf | ||
| Specs (MTC Report pgs 110 - 148).pdf | ||
| Addendum 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BOILER PLANT
LOCATION
N SITE MAP
file no.
checked by drawn by consultant issue date contract order no.
472LCFMaintProj consultant job no.
18344.00
M a tr ix
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
472/18414.SMD
CD SET 04.26.19
funding code sheet description
A-000
BRH/JKB
JFS
COVER SHEET
AutoCAD SHX Text
ARCHITECTURAL DRAWING INDEX
AutoCAD SHX Text
MECHANICAL/ELECTRICAL ENGINEER (PSC)
AutoCAD SHX Text MATRIX CONSULTING ENGINEERS, INC. 1601 E. CESAR E. CHAVEZ AVE. LANSING, MI 48906 (517) 487-2511
AutoCAD SHX Text
STATE OF MICHIGAN
AutoCAD SHX Text DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET FOR DEPARTMENT OF CORRECTIONS LAKELAND CORRECTIONAL FACILITY - DEAERATOR REPLACEMENT
AutoCAD SHX Text 141 1ST STREET COLDWATER, MI 49036 FUNDING CODE: 472LCFMAINTPROJ FILE NUMBER: 472/18414.SMD MATRIX PROJECT NUMBER: 18344.00
AutoCAD SHX Text
A-000 COVER SHEETCOVER SHEET
AutoCAD SHX Text
MECHANICAL DRAWING INDEX
AutoCAD SHX Text M-100 MECHANICAL SYMBOLS, NOTES, AND ABBREVIATIONS MECHANICAL SYMBOLS, NOTES, AND ABBREVIATIONS M-300 BASEMENT FLOOR PLAN - PIPING DEMOLITION BASEMENT FLOOR PLAN - PIPING DEMOLITION M-301 FIRST FLOOR PLAN - PIPING DEMOLITION FIRST FLOOR PLAN - PIPING DEMOLITION M-302 LOWER MEZZANINE PLAN - PIPING DEMOLITION LOWER MEZZANINE PLAN - PIPING DEMOLITION M-303 UPPER MEZZANINE PLAN - PIPING DEMOLITION UPPER MEZZANINE PLAN - PIPING DEMOLITION M-400 BASEMENT FLOOR PLAN - PIPING NEW BASEMENT FLOOR PLAN - PIPING NEW M-401 FIRST FLOOR PLAN - PIPING NEW FIRST FLOOR PLAN - PIPING NEW M-402 LOWER MEZZANINE PLAN - PIPING NEW LOWER MEZZANINE PLAN - PIPING NEW M-403 UPPER MEZZANINE PLAN - PIPING NEW UPPER MEZZANINE PLAN - PIPING NEW M-800 BOILER PIPING DIAGRAM - DEMOLITION BOILER PIPING DIAGRAM - DEMOLITION M-801 BOILER PIPING DIAGRAM - NEW BOILER PIPING DIAGRAM - NEW M-802 BOILER SYSTEM CONTROL WIRING DIAGRAM - NEW BOILER SYSTEM CONTROL WIRING DIAGRAM - NEW
AutoCAD SHX Text E-100 ELECTRICAL ABBREVIATIONS, SYMBOLS, AND NOTES ELECTRICAL ABBREVIATIONS, SYMBOLS, AND NOTES E-300 BASEMENT FLOOR PLAN - ELECTRICAL DEMOLITION BASEMENT FLOOR PLAN - ELECTRICAL DEMOLITION E-301 MEZZANINE PLAN - ELECTRICAL DEMOLITION MEZZANINE PLAN - ELECTRICAL DEMOLITION E-500 BASEMENT FLOOR PLAN - ELECTRICAL POWER BASEMENT FLOOR PLAN - ELECTRICAL POWER E-501 FIRST FLOOR PLAN - ELECTRICAL POWER FIRST FLOOR PLAN - ELECTRICAL POWER E-600 ELECTRICAL DEMOLITION RISER DIAGRAM ELECTRICAL DEMOLITION RISER DIAGRAM E-601 ELECTRICAL REVISED RISER DIAGRAMELECTRICAL REVISED RISER DIAGRAM
AutoCAD SHX Text
ELECTRICAL DRAWING INDEX
AutoCAD SHX Text
CODES
AutoCAD SHX Text 2015 - MICHIGAN BUILDING CODE 2015 - PLUMBING CODE 2015 - MECHANICAL CODE 2017 - NFPA 70 - NATIONAL ELECTRICAL CODE
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E. CESAR E. CHAVEZ AVE
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
LAKELAND CORRECTIONAL FACILITY
AutoCAD SHX Text
COLDWATER, MICHIGAN
AutoCAD SHX Text 18344.00
AutoCAD SHX Text
141 1ST STREET
AutoCAD SHX Text
DEAERATOR REPLACEMENT PROJECT
GENERAL HVAC NOTES
1. LOCATE EXHAUST OUTLETS OF VENTS AT LEAST 10 FEET
FROM OUTDOOR AIR INTAKES.
2. ALL EXISTING SYSTEMS (INCLUDING PUMPS) THAT SERVES
AREAS BEING RENOVATED SHALL BE REBALANCED AS
REQUIRED.
3. NOTIFY OWNER OF ANY PIPING OR DUCTWORK DEMOLITION
THAT MAY AFFECT NORMAL OPERATION OF OTHER AREAS.
4. FIELD VERIFY LOCATIONS OF EXISTING PIPING THAT MAY
CONFLICT WITH NEW CONSTRUCTION AND RELOCATE AS
NEEDED.
5. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER
DISCIPLINES PRIOR TO CONSTRUCTION TO AVOID CONFLICTS.
6. PROVIDE MANUAL AIR VENTS WITH 3/4" HOSE CONNECTION AT
ALL HIGH POINTS.
7. THE CONTRACTOR SHALL FIELD VERIFY THE SIZES, LOCATION,
ELEVATIONS, AND DETAILS OF ALL EXISTING CONDITIONS THAT
MAY AFFECT THE WORK.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING
THE INTEGRITY OF ALL EQUIPMENT AND MATERIALS IN A "NEW"
CONDITION DURING CONSTRUCTION.
9. ALL WORK SHALL BE PERFORMED BY LICENSED
CONTRACTORS AND SUBCONTRACTORS AS REQUIRED BY LAW.
10. ALL WORK SHALL CONFORM TO MICHIGAN MECHANICAL CODE,
LATEST APPLICABLE EDITION.
11. ALL CONDENSATE DRAIN PIPING SET @ MIN. 1% SLOPE.
12. ALL CONDENSATE DRAIN PIPING TO TERMINATE TO DRAIN VIA
AIR GAP.
13. IF THERE IS CONFLICTING INFORMATION IN THE PLANS OR
SPECIFICATIONS THE MORE STRINGENT AND GREATER COST
ITEM SHALL BE USED.
14. DRAWINGS INDICATE REQUIRED SIZES AND POINTS OF
TERMINATION OF PIPES AND DUCTS AND SUGGESTED ROUTES.
IT IS NOT INTENTION OF DRAWINGS TO INDICATE ALL
NECESSARY OFFSETS. INSTALL WORK IN MANNER TO
CONFORM TO STRUCTURE, AVOID OBSTRUCTIONS, PRESERVE
HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAR.
DO NOT SCALE FROM DRAWINGS.
15. CONTRACTOR IS RESPONSIBLE FOR PATCHING ALL ROOF
OPENINGS TO MATCH EXISTING AND MAINTAIN ALL ROOF
WARRANTIES. ROOFING CONTRACTOR MAINTAINING THE
ROOF WARRANTY IS SLATILE ROOFING AND SHEET METAL
COMPANY INCORPORATE, 574-233-7485.
16. CONTRACTOR IS RESPONSIBLE FOR PATCHING AND PAINTING
ALL WALL AND FLOOR PENETRATIONS THAT ARE NO LONGER
NEEDED. PATCHING AND PAINTING SHALL MATCH EXISTING.
17. BOILER SYSTEM TO REMAIN OPERATING THROUGHOUT THE
PROJECT. COORDINATE ANY TEMPORARY SHUTDOWNS WITH
OWNER. PROVIDE OWNER A MINIMUM OF 72 HOURS NOTICE
BEFORE ALL SHUTDOWNS. TEMPORARY SHUTDOWNS SHALL
NOT BE MORE THEN 7 HOURS AND ARE TO BE CONDUCTED AT
NIGHT FROM 9 PM - 4 AM.
18. CONTRACTOR'S WORKING HOURS TO BE 6:30 AM - 3 PM.
CONTRACTOR'S CAN WORK ANY DAY OF THE WEEK DURING
THAT TIMEFRAME.
19. CONTRACTOR TO PROVIDE A COMPLETE AND OPERABLE
SYSTEM. IF DIFFERENT EQUIPMENT MANUFACTURERS ARE
SELECTED BESIDES BASIS OF DESIGN MANUFACTURERS THE
CONTRACTOR IS RESPONSIBLE FOR ALL ASSOCIATED COST
REQUIRED TO BUILD AN EQUAL, COMPLETE, AND OPERABLE
SYSTEM AS CALLED ON OUT ON THE PRINTS AND
SPECIFICATIONS.
20. CONTRACTOR TO COORDINATE ALL PIPE ROUTING WITH
OWNER BEFORE INSTALLING.
21. CONTRACTOR CAN USE EXISTING CRANE LOCATED IN THE
BOILER PLANT, BUT OWNER MUST TRAIN THE OPERATORS
BEFORE USING.
22. CONTRACTOR IS RESPONSIBLE FOR ALL ASBESTOS AND LEAD
ABATEMENT REQUIRED TO COMPLETE THEIR SCOPE OF WORK.
MECHANICAL SYMBOLS LEGEND
HVAC PIPING SYMBOLSHVAC PIPING
HVAC DUCTWORK
F/S
F/S s s
TEMPERATURE CONTROL SYMBOLS
MISCELLANEOUS NOTES
HVAC DUCTWORK SYMBOLS HVAC DUCTWORK & DIFFUSER TAGS HVAC PIPING VALVES
MECHANICAL ABBREVIATIONS
AFF ABOVE FINISH FLOOR
AC AIR COMPRESSOR
AHU AIR HANDLING UNIT
AS AIR SEPARATOR
A.T.C. ARCHITECTURAL TRADES CONTRACTOR
B BOILER
B.A.S. BUILDING AUTOMATION SYSTEM
BD BLOW DOWN
CC COOLING COIL
CFM CUBIC FEET PER MINUTE
CHLR CHILLER
CHP CONSOLE HEAT PUMP
CONV CONVECTOR
CT COOLING TOWER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONTROL VALVE
CWP CHILLED WATER PUMP
DB DRY BULB
DFU DUCT FURNACE
DIA DIAMETER
DN DOWN
DPR DAMPER
DS DUCT SILENCER
EAT ENTERING AIR TEMPERATURE
EF EXHAUST FAN
EG EXHAUST GRILLE
E.T.C. ELECTRICAL TRADES CONTRACTOR
EVR EVAPORATOR
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EXIST EXISTING
FF FINISH FLOOR
FPM FEET PER MINUTE
FT FEET
FTR FINNED TUBE RADIATION
FU FURNACE
GAL GALLON
GFRH GAS FIRED RADIANT HEATER
GR GRILLE
H HUMIDIFIER
HC HEATING COIL
HD HEAD (FT)
HP HORSE POWER
HHP HORIZONTAL HEAT PUMP
HTG HEATING
HVAC HEATING, VENTILATION, & AIR CONDITIONING
HWP HEATING WATER PUMP
HX HEAT EXCHANGER
ID INSIDE DIAMETER
I.E. INVERT ELEVATION
IAH INTAKE HOOD
LAT LEAVING AIR TEMPERATURE
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH BTU PER HOUR (THOUSAND)
MIN MINIMUM
M.T.C. MECHANICAL TRADES CONTRACTOR
N.C. NOISE CRITERIA
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NTS NOT TO SCALE
LPS LOW PRESSURE STEAM
P PUMP
PSC PUMPED STEAM CONDENSATE
PD PRESSURE DROP
RCP RADIANT CEILING PANEL
REQ'D REQUIRED
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RLH RELIEF HOOD
RTU ROOF TOP UNIT
SD SUPPLY DIFFUSER
SCW SOFT COLD WATER
SF SUPPLY FAN
SG SUPPLY GRILLE
SH SENSIBLE HEAT (MBH)
SM SHEET METAL
SQ. FT. SQUARE FEET
SST SATURATED SUCTION TEMPERATURE
STR STRAINER
TC TOTAL COOLING (MBH)
TCL TEMPERATURE CONTROL
T&P TEMPERATURE & PRESSURE RELIEF VALVE
TYP TYPICAL
UH UNIT HEATER
VAV VARIABLE AIR VOLUME BOX
VRH VARIABLE AIR VOLUME REHEAT BOX
FPVAV FAN POWERED VARIABLE AIR VOLUME BOX
V.F.D VARIABLE FREQUENCY DRIVE
ZD ZONE DAMPER
X-SA EXISTING ITEM (EXISTING SUPPLY AIR DUCT)
ITEM
EXISTING
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CONDENSATE DRAIN
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
COOLING TOWER WATER SUPPLY
COOLING TOWER WATER RETURN
DIRECT EXPANSION
HEAT PUMP WATER SUPPLY
HEAT PUMP WATER RETURN
HEATING WATER SUPPLY
HEATING WATER RETURN
SUCTION (REFRIGERANT)
LIQUID (REFRIGERANT)
SUCTION (DIRECT EXPANSION)
LIQUID (DIRECT EXPANSION)
LOW PRESSURE STEAM (0-20 LBS.)
MEDIUM PRESSURE STEAM (21-75 LBS.)
HIGH PRESSURE STEAM (76 LBS. & ABV.)
STEAM CONDENSATE (GRAVITY)
PUMPED STEAM CONDENSATE
STEAM CONDENSATE BOILER FEED
GATE VALVE
GAS COCK
CHECK VALVE
BALANCE COCK
CIRCUIT SETTER
TWO-WAY CONTROL VALVE
THREE-WAY CONTROL VALVE
GLOBE VALVE
BALL VALVE
SOLENOID VALVE
EXPANSION VALVE WITH
THERMOSTATIC BULB
PLUG VALVE
BUTTERFLY VALVE
RELIEF VALVE
HOSE & DRAIN END VALVE
PRESSURE RELIEF VALVE
PRESSURE REDUCING VALVE
TRIPLE DUTY VALVE
GAS PRESSURE REGULATOR
STRAINER (BLOW-OFF)
FLOW DIRECTION
PIPING DROP
PIPING RISE
INLINE PIPING DROP
INLINE PIPING RISE
PIPING TEE
PIPING ELBOW
THERMOMETER
PUMP
UNION
PIPE ANCHOR
PIPE GUIDE
BACK FLOW PREVENTER
PIPE CAP
PIPE BREAK
THERMOMETER WELL
EXPANSION LOOP
EXPANSION COMPENSATOR
FLOAT & THERMOSTATIC STEAM TRAP
INVERTED BUCKET STEAM TRAP
THERMOSTAT
PROGRAMMABLE THERMOSTAT
THERMOSTAT (W/ NIGHT SETBACK)
ROOM SENSOR
HUMIDISTAT
PRESSURE GAUGE
DAMPER (ELECTRIC OPERATION)
DAMPER (PNEUMATIC OPERATION)
DAMPER BLADES
SUPPLY AIR DUCT
EXIST SUPPLY AIR DUCT
RETURN AIR DUCT
EXIST RETURN AIR DUCT
OUTSIDE AIR DUCT
EXIST OUTSIDE AIR DUCT
EXHAUST AIR DUCT
EXIST EXHAUST AIR DUCT
SUPPLY AIR DUCT RISER
RETURN AIR DUCT RISER
OUTSIDE AIR DUCT RISER (AS NOTED)
EXHAUST AIR DUCT
INSULATED DUCTWORK (AS NOTED)
SUPPLY AIR DIFFUSER (SQUARE)
SUPPLY AIR DIFFUSER (INLINE)
TURNING VANES
SURFACE MTD. GRILLE
SUPPLY AIR DIFFUSER (ROUND)
90° TEE W/45° APPROACH
CONICAL TAKE-OFF
CONICAL TAKE-OFF W/ DAMPER
BALANCE DAMPER
RETURN AIR DUCT BOOT
ECCENTRIC REDUCER
CONCENTRIC REDUCER
VERTICAL FIRE DAMPER
EXISTING VERTICAL FIRE DAMPER
HORIZONTAL FIRE DAMPER
EXISTING HORIZONTAL FIRE DAMPER
VERTICAL SMOKE DAMPER
HORIZONTAL SMOKE DAMPER
VERTICAL FIRE / SMOKE DAMPER
HORIZONTAL FIRE / SMOKE DAMPER
DUCT SMOKE DETECTOR, INSTALLED BY M.T.C.,
PROVIDED & WIRED BY E.T.C.
UNIT HEATER
CEILING EXHAUST FAN
ROOF MOUNTED EXHAUST FAN
DEMOLITION
POINT OF CONNECTION BETWEEN NEW AND
EXISTING
POINT OF EXISTING TO REMAIN AND EXISTING
TO BE REMOVED
INDICATES PLAN NOTE
INDICATES DEMOLITION NOTE
DETAIL BUBBLE
DETAIL NUMBER
PAGE LOCATION INDICATES
DIRECTION OF DETAIL SECTION
X
X
XX
XXXX
XX
XXXX
SA
OA
X-OA
X-EA
EA
X-SA
X-RA
RA
SCP
SC
DXS
DXL
HR
CR
CD
CS
DX
CTR
HPR
HS
HPS
CTS
CWR
CWS
S
L
LPS
MPS
HPS
SC (BF)
TAG CFM
NECK REMARKS
SIZE
BT
FT
SD-1 250
8"ø ---
P
H
S
T
T P
T N
M
M
SD
OVERALL PROJECT PHASING
1. THE SEQUENCING OF THE DEAERATOR REPLACEMENT SHALL
ALLOW FOR THE EXISTING BOILER SYSTEM TO REMAIN
FUNCTIONAL THROUGHOUT THE PROJECT, EXCEPT FOR
TEMPORARY SHUTDOWNS.
2. INSTALL ALL SWITCH OVER SHUT OFF VALVES DURING THE
SUMMER MONTHS TO ALLOW THE SWITCH OVER FROM THE
OLD DEAERATOR TO NEW DEAERATOR WITH A MINIMUM
SHUTDOWN.
3. ALL PHASES AND SHUTDOWNS TO BE CLOSELY
COORDINATED WITH THE OWNER.
1. ALL PLUMBING WORK SHALL CONFORM TO MICHIGAN
PLUMBING CODE, LATEST APPLICABLE EDITION.
2. INSTALL ISOLATION BALL VALVES @ ALL EQUIPMENT
BRANCH WATER SUPPLY LINES.
3. ALL PIPE SIZES SHOWN ARE SERVICE SIZE. SIZE
SLEEVES FOR 1" CLEAR SPACE BETWEEN PIPE AND
SLEEVE FOR INSTALLATION OF MECHANICAL SEAL.
4. CONTRACTOR SHALL DEMOLISH & REMOVE EXISTING
PIPING, FITTINGS, & EQUIPMENT AS REQUIRED FOR NEW
INSTALLATIONS. VALVE & CAP PIPING TO REMAIN.
5. FIELD VERIFY LOCATIONS OF EXISTING PIPING THAT MAY
CONFLICT WITH NEW CONSTRUCTION AND RELOCATE
AS NEEDED.
6. NOTIFY OWNER OF ANY PIPING DEMOLITION THAT MAY
AFFECT NORMAL OPERATION OF OTHER AREAS.
7. 1% SLOPE FOR ALL DRAIN PIPING.
8. PROVED AIR ELIMINATION DEVICES FOR EACH PLUMBING
SYSTEM.
9. THE CONTRACTOR SHALL FIELD VERIFY THE SIZES,
LOCATION, ELEVATIONS, AND DETAILS OF ALL EXISTING
CONDITIONS THAT MAY AFFECT THE WORK.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
MAINTAINING THE INTEGRITY OF ALL EQUIPMENT AND
MATERIALS IN A "NEW" CONDITION DURING
CONSTRUCTION.
11. ALL WORK SHALL BE PERFORMED BY LICENSED
CONTRACTORS AND SUBCONTRACTORS AS REQUIRED
BY LAW.
12. DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE
WITH THE CODES AND REGULATIONS ENFORCED BY
LOCAL BUILDING OFFICIALS.
13. IF THERE IS CONFLICTING INFORMATION IN THE PLANS
OR SPECIFICATIONS THE MORE STRINGENT AND
GREATER COST ITEM SHALL BE USED.
14. DRAWINGS INDICATE REQUIRED SIZES AND POINTS OF
TERMINATION OF PIPES AND SUGGESTED ROUTES. IT IS
NOT INTENTION OF DRAWINGS TO INDICATE ALL
NECESSARY OFFSETS. INSTALL WORK IN MANNER TO
CONFORM TO STRUCTURE, AVOID OBSTRUCTIONS,
PRESERVE HEADROOM AND KEEP OPENINGS AND
PASSAGEWAYS CLEAR. DO NOT SCALE FROM
DRAWINGS.
GENERAL PLUMBING NOTES
REVERSE OSMOSIS SYSTEM SCHEDULE (RO-1)
CARBON FILTER
CARBON FILTER BASED ON BESCO MARLO ACE-16G-1" SINGLE CARBON BW FILTER OR APPROVED EQUAL, 7 GPM
CONTINUOUS FLOW, 14 GPM PEAK GPM, 13 GPM BACK WASH, 1" SERVICE AND DRAIN SIZE, 4 CUBIC FOOT MEDIA, 16" DIAMETER x 65" TALL TANK SIZE, 16" WIDE x 16" DEEP x 73" TALL OVERALL DIMENSIONS, 245 SHIPPING WEIGHT, ACTIVATED CARBON FILTER, NORYL CONTROL VALVE BODY, FIBERGLASS REINFORCED POLYETHYLENE - (FRP) NSF 44 CERTIFIED, SCHEDULE 80 PVC/ABS INTERNAL DISTRIBUTORS, CONTROLS TO INCLUDE CLACK DIGITAL CONTROL TIMERS, TIMECLOCK INITIATED BACKWASH CYCLE, AND AUTOMATIC BACKWASH FLOW CONTROLLER, 25-125 PSIG
INLET PRESSURE, 120 VOLT WALL MOUNT TRANSFORMER, 40-110°F OPERATING TEMPERATURE
REVERSE OSMOSIS SYSTEM
REVERSE OSMOSIS SYSTEM BASED ON BESCO MARLO MRO-9000-4V OR APPROVED EQUAL. 6.3 DESIGN GPM, 9,000
GALLONS PER DAY, 5 ELEMENT QUANTITY, 8.4-9.7 GPM RO FEED GPM, 2.1-3.4 GPM RO REJECT, 0.75" INLET AND PRODUCT FLANGE, 0.5" REJECT FLANGE, 230 PSI NOMINAL OPERATING PRESSURE, 575 APPROXIMATE SHIPPING WEIGHT, 36" LENGTH x 30" WIDTH, x 68" TALL OVERALL DIMENSIONS. REVERSE OSMOSIS SYSTEM TO BE A PREPIPED AND PREWIRED PACKAGED SYSTEM. 200-250 PSIG OPERATING PRESSURE, 65-75% NOMINAL RECOVERY, 98-99% NOMINAL SALT REJECTION, 45-85°F OPERATING TEMPERATURE, 30 PSIG MINIMUM INLET PRESSURE, SOFTENED INLET WATER QUALITY, 120 VOLT 1 PHASE CONTROL CIRCUIT, EPOXY-COATED CARBON STEEL SKID FRAME, THIN-FILM COMPOSITE MEMBRANE ELEMENTS, FRP MEMBRANE HOUSINGS, SCHEDULE PVC LOW PRESSURE PIPING, 304 STAINLESS STEEL HIGH PRESSURE PIPING, 304SS VERTICAL MULTI-STAGE CENTRIFUGAL PUMP WITH TEFC, 5 HP, 208 VOLT, 3 PHASE MOTOR DISCONNECT BY EC. 4" x 40" HIGH REJECTION MEMBRANE ELEMENTS, 5-MICRON SEDIMENT PRE-FILTER HOUSING, AUTOMATIC INLET SHUT-OFF VALVE, SOLID-STATE NEMA-4X DIGITAL CONTROL, PRODUCT WATER CONDUCTIVITY MONITOR, OPERATING PRESSURE GAUGES, PRODUCT AND CONCENTRATE FLOW METERS, CONCENTRATE AND RECYCLE FLOW CONTROL VALVES, LOW INLET PRESSURE SWITCH WITH SHUTDOWN
ALARM.
REVERSE OSMOSIS TANK
TANK BASED ON PLASTIC-MART MODEL VT1000-64 OR APPROVED EQUAL, 1000 GALLON VERTICAL TANK, 64" DIAMETER x
81" TALL, POLYETHYLENE TANK, 250 POUNDS SHIPPING WEIGHT, 0.31 NOMINAL WALL THICKNESS, 16 INCH VENTED LID, MOLDED GALLON MARKERS ON THE OUTSIDE OF THE TANK. 3 YEAR WARRANTY, 2" THREADED OUTLET
FITTINGS, FDA COMPLIANT RESINS AND NSF APPROVED.
REVERSE OSMOSIS BOOSTER PUMP
BOOSTER PUMP BASED ON GRUNDFOS MQ 3-35 OR APPROVED EQUAL. 1 HP, 120 VOLT, 1 PHASE WITH POWER CORD AND
PLUG. PUMP TO INCLUDE PUMP, MOTOR, DIAPHRAGM TANK, PRESSURE AND FLOW SENSOR, CONTROLLER, AND CHECK VALVE, CONTROL PANEL WITH ON/OFF BUTTON AND INDICATOR LIGHTS FOR INDICATION OF THE OPERATIONAL STATE OF THE PUMP, SELF PRIMING, PUMP OVERLOAD PROTECTION, AUTOMATIC RESET FEATURE, LESS THAN 55 DBA, NO MAINTENANCE PUMP
MOTOR STOOL WITH BASE PLATE: POLYOXIMETYLEN + 25% GLASS MATERIAL
CHAMBER POLYPHENYLENE OXIDES + 20% GLASS FIBER
DRAIN AND PRIMING PLUG: POLYOXIMETYLEN + 25% GLASS MATERIAL
SELF-PRIMING VALVE: POLYPROPYLENE + 30% GLASS FIBER
SELF-PRIMING PART: POLYPHENYLENE OXIDES + 20% GLASS FIBER
PUMP SLEEVE: STAINLESS STEEL
PRESSURE TANK: BUTYL (DIAPHRAGM)
IMPELLER: POLYPHENYLENE + 20% GLASS FIBER
NON-RETURN VALVE: POLYOXIMETYLEN + 25% GLASS FIBER
CLAMP: STAINLESS STEEL
DISCHARGE AND SUCTION PORTS: POLYOXIMEYLEN + 25% GLASS FIBER
SHAFT SEAL (STATIONARY AND ROTATING PART): CARBON/CERAMINCS/NBR RUBBER
SHAFT AND MOTOR SLEEVE: STAINLESS STEEL
O-RINGS: NBR-RUBBER
ALL REVERSE OSMOSIS SYSTEM COMPONENTS TO BE ASSEMBLED BY THE CONTRACTOR PER THE MANUFACTURER'S
INSTALLATION INSTRUCTIONS FOR A COMPLETE AN OPERABLE SYSTEM.
1. BASE BID: CONTRACTOR TO DEMO AND ABATE ASBESTOS
ON THE EXISTING PIPING AND EQUIPMENT ONLY AS NEEDED
TO COMPLETE THE NEW WORK. ALL OTHER PIPING TO BE
ABANDONED. CONTRACTOR TO FLAG ABANDONED PIPING
WITH SPRAY PAINT. COORDINATE WITH OWNER ON SPRAY
PAINT MARKINGS OF THE ABANDONED PIPING. CAP ALL
ABANDONED PIPING AND ACTIVE PIPING.
2. ADD ALTERNATE #1: CONTRACTOR TO REMOVE ALL
ASBESTOS AND LEAD FROM PIPING AND EQUIPMENT THAT
WILL BE ABANDONED FROM THIS PROJECT.
3. ADD ALTERNATE #2: CONTRACTOR TO REMOVE ALL PIPING
AND EQUIPMENT THAT WILL BE ABANDONED FROM THIS
PROJECT.
PIPING AND EQUIPMENT
DEMOLITION CLARIFICATION
4"
ADHESIVE ANCHOR EQUIP. PAD W/ #4
DOWELS INTO CONC. FLOOR SLAB &
CONCRETE PLANKS W/ 3" EMBED.
PLACED 24" O.CO EACH WAY
3/4" CHAMFER, TYP.
X-CONCRETE FLOOR
X-CONCRETE TOPPING
REINF. CONC. EQUIP. PAD
W/ 6x6 W2.9xW2.9 WELDED
WIRE FABRIC
4"
PER EQUIPMENT
MANUFACTURER
file no.
checked by drawn by consultant issue date contract order no.
472LCFMaintProj consultant job no.
18344.00
M a tr ix
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
472/18414.SMD
CD SET 04.26.19
funding code sheet description
M-100
BRH
CAT
MECHANICAL SYMBOLS,
NOTES, AND
ABBREVIATIONS
HOUSEKEEPING PAD DETAIL1
SCALE: 3/4" = 1'-0"
0 1 3
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E. CESAR E. CHAVEZ AVE
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
LAKELAND CORRECTIONAL FACILITY
AutoCAD SHX Text
COLDWATER, MICHIGAN
AutoCAD SHX Text 18344.00
AutoCAD SHX Text
141 1ST STREET
X-3" PSC UP
X-4" SCW UP
X-8" SC (BF) UP
TO X-DA TANK
X-2" SCW UP
TO
X-BFP-1
X-BFP-2
X-4"
X-BFP-3
X-MAKEUP CW
X-SC PUMP
W/ VFD
X-MAKE UP
WATER VALVE
X-
PS
C
X-
SC
(B F)
X-4"
X-4"
X-
CW
X-2" SCW UP
X-3" SC
(BF) TO PIT
X-3"
X-SC TANK LEVEL
CONTROLLER
1X-SC PUMP
CONTROL PANEL
X-
PS
C X-3"
X-SC PUMP
W/ VFD
X-3"
X-
CO
ND
EN
SA
TE
T
AN
K
X-2"
X-
SC
X-6"
SC (BF)
X-1" SC UP TO
X-DA TANK
X-
SC
X-WATER
SOFTENER
X-6"
X-
SC
W
X-6"
X-
CW
X-SCW
X-PUMP VFD
X-PUMP
X-BD
X-2" DRAIN UP
X-3/4" UP
X-2"
X-2" BD UP
NC
X-2" DN TO
TRENCH
X-2"X-2"
X-2" BD UP X-2" BD UP
X-3/4" UP X-3/4" UP
X-SC FROM
TUNNEL
X-3" SC TO
DWH
NC
X-WATER
SOFTENER
X-WATER
SOFTENER
X-CW
X-TRANSFER
SWITCH
X-ELECTRICAL
PANEL
X-ELECTRICAL
PANEL
X-4"
X-CW
X-BLOWDOWN
SEPARTATOR
X-4" V UP
X-2"
X-BD
X-2"
X-
BD
X-
BDX-
BD
X-2"
X-
SC
W
X-SCW
X-2" SCW UP TO
X-DEALKALIZER
X-2"
X-PUMP
(ABANDONED)
X-2" SCW
X-SCW
X-CW
X-4"
X-4"
X-4"
X-4"
X-CW
NC
NO
X-
SC
W
X-4" SCW
NC
X-4" SCW TO
X-DWH
X-4" SCWX-PSC
X-SCW
X-SCW
X-BD
X-8"
X-4"
X-4"
X-2" SC
(BF) UP
X-2" SC
(BF) UP
X-4"
X-
CW
X-3"
X-
CW
X-3"
X-3" CW
NC
X-6"
X-PRV
X-8" LPS
TO X-DWH
X-3" HPS
X-6" HPS FROM
STM HEADER
X-6" X-3"
X-10"
X-LPSX-LPS
X-10" LPS UP
X-CW
X-2"
X-CW X-CW
X-2"
X-2" CW DN
TO OUTLET
X-2" SC (BF)
FROM PIT
X-SC
X-2"
NC
X-TRANSFORMER
X-SUMP
OPEN TO MAIN
FLR ABOVE
X-2" SC
(BF) UP
X-LPS TO
TUNNEL
1 2
1 2 1 2
1 2
1 2
1 2
X-SC
X-TRENCH
CATCH BASIN
1 2 3
X-3/4"
DEMOLITION NOTES
DISCONNECT, REMOVE, AND DEMO EXISTING STEAM CONDENSATE PUMP
CONTROL PANEL. EXISTING VFD'S TO REMAIN.
DISCONNECT, REMOVE, AND DEMO EXISTING MAKE UP WATER VALVE. DEMO
PIPING TO EXTENTS SHOWN.
DISCONNECT, REMOVE, AND DEMO EXISTING STEAM CONDENSATE LEVEL
CONTROLLER.
ADD ALTERNATE NOTES
ADD ALTERNATE #1: ABATE ALL ASBESTOS FROM ABANDONED EXISTING
EQUIPMENT AND PIPING.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO EXISTING
EQUIPMENT AND PIPING TO EXTENTS SHOWN AND CAP.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO EXISTING BOILER
FEED PUMP AND ALL ASSOCIATED ACCESSORIES. DEMO EXISTING PIPING
TO EXTENTS SHOWN AND CAP. DEMO EXISTING CONCRETE HOUSEKEEPING
PADS.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO EXISTING
DEALKALIZER PIPING TO EXTENTS SHOWN AND CAP.
ADD ALTERNATE #2: DEMO EXISTING 8" BOILER FEED PIPING, 1" SC PIPING,
AND DA DRAIN PIPING TO EXTENTS SHOWN AND CAP.
file no.
checked by drawn by consultant issue date contract order no.
472LCFMaintProj consultant job no.
18344.00
M a tr ix
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
472/18414.SMD
CD SET 04.26.19
funding code sheet description
N BASEMENT FLOOR PLAN - PIPING DEMOLITION
SCALE: 1/4" = 1'-0"
0 1 5 10
M-300
BRH
CAT
BASEMENT FLOOR PLAN -
PIPING DEMOLITION
AutoCAD SHX Text
UP
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E. CESAR E. CHAVEZ AVE
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
LAKELAND CORRECTIONAL FACILITY
AutoCAD SHX Text
COLDWATER, MICHIGAN
AutoCAD SHX Text 18344.00
AutoCAD SHX Text
141 1ST STREET
X-10" LPS UP/DN
X-BSC 2300
X-CHEMICAL
PUMPS
X-2" SCW DN
X-3" UP
TO X-FD
X-2" DRAIN UP
TO X-DA TANK
X-8" BF UP TO
X-DA TANK
X-AMINE
TANK
X-2" SCW UP
X-2" DRAIN DN
X-8" SC (BF) DN
X-2" SCW DN
X-SCW
X-1-1/4" SCW
X-2" SCW
THRU WALL
X-2" SCW UP TO
X-DEALKALIZER
X-4" UP
TO X-FD
X-1-1/2" SCW UP
X-OX 2306
SULFITE
X-DEALKALIZER
BRINE PUMP
X-4" SCW UP/DN
X-2" SCW UP/DN
X-3" PSC UP/DN
X-BOILER X-BOILER X-BOILER
X-3" SC
(BF) DN
X-3" SC
(BF) UP
X-3" SC
(BF) DN
X-3" SC
(BF) UP
X-3" SC
(BF) DN
X-3" SC
(BF) UP
111111
X-1" SC UP TO
X-DA TANK
X-SC X-1" SC
DN
X-
SC
W
X-AMINE
X-BSC-2300
X-CHEMICAL
TANK
X-1" CHEM UP
TO X-DA
X-CHEMICAL
MIXING TANK
X-CHEM FEED TO
BOILERS (TYP. 3)
3X-CHEMICAL
FEED PUMP
X-3/4" SCW
1/2"
1 21 2
1 2
1 2
4" NEW HOUSEKEEPING
PAD
1 2 4
1 2 4
DEMOLITION NOTES
1 EXISTING BOILER FEED PIPING AND CONTROLS TO REMAIN.
DISCONNECT, REMOVE, AND DEMO EXISTING CHEMICAL
FEED PIPING AS REQUIRED TO BE REROUTED TO NEW
REVERSE OSMOSIS SYSTEM. EXISTING CHEMICAL STORAGE
TANKS TO REMAIN.
DISCONNECT, REMOVE, AND DEMO EXISTING CHEMICAL
PUMP.
CONTRACTOR TO REMOVE EXISTING FLOOR TILES IN THE
LOCATION OF THE NEW HOUSEKEEPING PAD BEFORE
POURING THE NEW HOUSEKEEPING PAD. ALL FLOOR TILES
AROUND THE NEW HOUSEKEEPING PAD SHALL REMAIN.
ADD ALTERNATE NOTES
ADD ALTERNATE #1: ABATE ALL ASBESTOS FROM
ABANDONED EXISTING EQUIPMENT AND PIPING.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO
EXISTING EQUIPMENT AND PIPING TO EXTENTS SHOWN AND
CAP.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO
EXISTING DEALKALIZER SUPPLY PIPING FROM DEALKALIZER
TO EXTENTS SHOWN IN BASEMENT AND CAP.
ADD ALTERNATE #2: DEMO EXISTING DEALKALIZER BRINE
PUMP AND ALL ASSOCIATED ACCESSORIES. DEMO PIPING TO
EXTENTS SHOWN.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO
EXISTING 8" BOILER FEED PIPING, 1" SC PIPING, AND 2" DRAIN
PIPING TO EXTENTS SHOWN.
file no.
checked by drawn by consultant issue date contract order no.
472LCFMaintProj consultant job no.
18344.00
M a tr ix
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
472/18414.SMD
CD SET 04.26.19
funding code sheet description
N FIRST FLOOR PLAN - PIPING DEMOLITION
SCALE: 1/4" = 1'-0"
0 1 5 10
M-301
BRH
CAT
FIRST FLOOR PLAN - PIPING
DEMOLITION
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E. CESAR E. CHAVEZ AVE
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
LAKELAND CORRECTIONAL FACILITY
AutoCAD SHX Text
COLDWATER, MICHIGAN
AutoCAD SHX Text 18344.00
AutoCAD SHX Text
141 1ST STREET
X-3" FD
X-2" ABANDONED SCW
CONTROL VALVE
X-4" SCW
UP/DN
X-3/4" SCW DN
TO EYE WASH
M
X-2" SCW DN
X-2" CW DN
X-
DR
AI
N
BI
N
X-SCW
X-DA TANK
X-
SC
W
X-6" HPS DN
TO TUNNEL
X-8" HPS
HEADER
X-HPS FROM
BOILER
X-SCW
X-
SC
W
X-CW
X-1-1/4"
X-6" HPS DNX-6" VTR
X-1" SC DN TO
X-BOILER FEED
PUMPS
X-10" LPS
UP/DN
X-3" SC
X-3" V
X-3/4" DN TO COOLER
X-1-1/4" SCW DN
X-3/4"
X-DEALKALIZER
X-DEALKALIZER
X-BOILER X-BOILER X-BOILER
X-HPS FROM
BOILER
X-
SC
(B F)
X-
SC
(B F)
X-
SC
(B F)
X-3" X-3" X-3"
X-3" SC
(BF) DN
X-8" X-8"
X-HPS FROM
BOILER
X-8"
X-3" SC
(BF) DN
X-3" SC
(BF) DN
1 2
1 2
1 2
1 2
DEMOLITION NOTES
DISCONNECT, REMOVE, AND DEMO EXISTING CAP AS REQUIRED TO
CONNECT TO NEW PIPING.
EXISTING BOILER FEED PIPING TO REMAIN AS SHOWN.
ADD ALTERNATE NOTES
ADD ALTERNATE #1: ABATE ALL ASBESTOS FROM ABANDONED EXISTING
EQUIPMENT AND PIPING.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO EXISTING
EQUIPMENT AND PIPING TO EXTENTS SHOWN AND CAP.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO EXISTING
DEALKALIZER EQUIPMENT AND ALL ASSOCIATED ACCESSORIES. DEMO
EXISTING PIPING TO EXTENTS SHOWN AND CAP. DEMO EXISTING CONCRETE
DRAIN BIN.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO EXISTING
DEAERATOR, CONTROLS, AND ALL ASSOCIATED ACCESSORIES. DEMO
EXISTING PIPING TO EXTENTS SHOWN AND CAP.
file no.
checked by drawn by consultant issue date contract order no.
472LCFMaintProj consultant job no.
18344.00
M a tr ix
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
472/18414.SMD
CD SET 04.26.19
funding code sheet description
N LOWER MEZZANINE PLAN - PIPING DEMOLITION
SCALE: 1/4" = 1'-0"
0 1 5 10
M-302
BRH
CAT
LOWER MEZZANINE PLAN -
PIPING DEMOLITION
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E. CESAR E. CHAVEZ AVE
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
LAKELAND CORRECTIONAL FACILITY
AutoCAD SHX Text
COLDWATER, MICHIGAN
AutoCAD SHX Text 18344.00
AutoCAD SHX Text
141 1ST STREET
X-10" STM
X-V THRU
WALL
X-4" SCW DN
X-10" LPS DN,
8" VTR
X-1-1/2"
X-DA
TANK
X-V X-3"
X-3" V DN
TO X-DA
X-SC
X- V
X-1-1/2" V
DN TO X-DA
X-SCWX-2" SCW DN X-CW
X-4" MAKE UP
WATER DN TO X-DA
X-3" LPS TO EXISTING
UNIT HEATERS LOCATED
ON MAIN FLOOR
X-
LP
S
X-LPS
X-4"
X-3" SC DN
X-3"
1 2
1 2
1 2
ADD ALTERNATE NOTES
ADD ALTERNATE #1: ABATE ALL ASBESTOS FROM ABANDONED EXISTING
EQUIPMENT AND PIPING.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO EXISTING
EQUIPMENT AND PIPING TO EXTENTS SHOWN AND CAP.
ADD ALTERNATE #2: DISCONNECT, REMOVE, AND DEMO EXISTING
DEAERATOR, CONTROLS, VENT, AND ALL ASSOCIATED ACCESSORIES.
DEMO EXISTING PIPING TO EXTENTS SHOWN AND CAP.
file no.
checked by drawn by consultant issue date contract order no.
472LCFMaintProj consultant job no.
18344.00
M a tr ix
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
472/18414.SMD
CD SET 04.26.19
funding code sheet description
N UPPER MEZZANINE PLAN - PIPING DEMOLITION
SCALE: 1/4" = 1'-0"
0 1 5 10
M-303
BRH
CAT
UPPER MEZZANINE PLAN -
PIPING DEMOLITION
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E. CESAR E. CHAVEZ AVE
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
LAKELAND CORRECTIONAL FACILITY
AutoCAD SHX Text
COLDWATER, MICHIGAN
AutoCAD SHX Text 18344.00
AutoCAD SHX Text
141 1ST STREET
X-3" PSC UP
X-4" SCW UP
X-2" SCW UP
TO
X-4"
X-MAKEUP CW
X-SC PUMP
W/ VFD
X-
PS
C
X-
CW
X-2" SCW UP
X-3" SC
(BF) TO PIT
X-3"
X-
PS
C X-3"
X-SC PUMP
W/ VFD
X-3"
X-
CO
ND
EN
SA
TE
T
AN
K
X-
SC
X-6"
SC (BF)
X-WATER
SOFTENER
X-6"
X-
SC
W
X-6"
X-
CW
X-SCW
X-PUMP VFD
X-PUMP
X-BD
X-3/4" UP
X-2"
X-2" BD UP
NC
X-2" DN TO
TRENCH
X-2"X-2"
X-2" BD UP X-2" BD UP
X-3/4" UP X-3/4" UP
X-SC FROM
TUNNEL
X-3" SC TO
DWH
NC
X-WATER
SOFTENER
X-WATER
SOFTENER
X-CW
X-TRANSFER
SWITCH
X-ELECTRICAL
PANEL
X-ELECTRICAL
PANEL
X-4"
X-CW
X-BLOWDOWN
SEPARTATOR
X-4" V UP
X-2"
X-BD
X-2"
X-
BD
X-
BDX-
BD
X-2"
X-
SC
W
X-SCW
X-2"
X-PUMP
(ABANDONED)
X-2" SCW
X-SCW
X-CW
X-4"
X-4"
X-4"
X-4"
X-CW
NC
NO
X-
SC
W
X-4" SCW
NC
X-4" SCW TO
X-DWH
X-4" SCWX-PSC
X-SCW
X-SCW
X-2" SC
(BF) UP
X-2" SC
(BF) UP
X-4"
X-
CW
X-3"
X-
CW
X-3"
X-3" CW
NC
X-6"
X-PRV
X-8" LPS
TO X-DWH
X-3" HPS
X-6" HPS FROM
STM HEADER
X-6" X-3"
X-10"
X-LPSX-LPS
X-10" LPS UP
X-CW
X-2"
X-CW X-CW
X-2"
X-2" CW DN
TO OUTLET
X-2" SC (BF)
FROM PIT
X-SC
X-2"
NC
X-TRANSFORMER
X-SUMP
OPEN TO MAIN
FLR ABOVE
X-2" SC
(BF) UP
X-LPS TO
TUNNEL
X-SC
X-TRENCH
CATCH BASIN
X-3/4"
MAKE UP
WATER VALVE
GEMS LEVEL
CONTROLLER
SCW
RO WATER
STORAGE TANK
REVERSE
OSMOSIS
SYSTEM
CARBON
FILTER
2"
2" RO UP
TO DA-1
2"
PU
MP
2" RO
NC
M
WATER
METER
2"
RO
2"
R O
2"
R O
2" BD UP
TO DA-1
BD
BD
2"
2"
RE
CI
RC
4" OVERFLOW
UP TO DA-1
RECIRC
2"
RO-1
NO
NC
3/4" SULFITE UP
3/4" SULFITE UP
TO NEW DA TANK
3" PSC
3" PSC UP
TO DA-1
X-LPS TO
TUNNEL
4" BF UP
2" RECIRC UP
BF
4"
O
VE
R
FL
O W
1/2" CHEM.
FEED UP
4" OVERFLOW DN TO X-TRENCH
DRAIN CATCH BASIN
NC
NO
3/4" RO UP
2"
R O
C H
EM
IC
AL
F
EE
D
1/2"
3/4"
R O
C H
EM
IC
AL
F
EE
D
1/2"
3/4"
RO
CHEMICAL FEED
1/2"
3/4"
4" HPS UP
4" HPS UP
3/4" SC
HP
S
5#
HPS 125#
4" DRAIN DOWN TO X-TRENCH
DRAIN CATCH BASIN
3/4" DRAIN
3/4" DRAIN
3/4" DRAIN UP
TO SAMPLE
COOLER
4"
BT
BUCKET TRAP
4" HPS 125#
PIPING KEY NOTES
INSTALL NEW GEMS LEVEL CONTROLLER FOR EXISTING
CONDENSATE TANK AND NEW MAKE UP WATER VALVE.
ALTER PIPING AS REQUIRED TO CONNECT TO NEW RO
PIPING.
INSTALL NEW REVERSE OSMOSIS SYSTEM IN LOCATION
SHOWN ON NEW 4" CONCRETE HOUSEKEEPING PADS.
REFER TO DETAIL ON M-100
CONTRACTOR TO NOT RUN PIPING THROUGH/OR
UNDER FLOOR OPENING. ALL NEW PIPING TO BE
ROUTED AROUND FLOOR OPENING.
CONTRACTOR TO CONNECT THE EXISTING
CONDENSATE PUMPS AND NEW GEMS LEVEL
CONTROLLER TO DEAERATOR ADAC CONTROL PANEL.
IF THE LEAD CONDENSATE PUMP FAILS SEND AN
ALARM TO THE SCADA SYSTEM AND START THE
STANDBY PUMP.
LEAVE AIR GAP FOR OPERATOR TO SEE IF OVERFLOW
IS BEING DRAINED TO TRENCH DRAIN CATCH BASIN.
REROUTE (3) EXISTING 3/4" COPPER COMPRESSED AIR
PIPING PIPES AS NEEDED TO ROUTE NEW STEAM
PIPING TIGHT TO THE BASEMENT CEILING. MOVE
EXISTING UNISTRUT PIPE SUPPORT AS NEEDED TO
ROUTE NEW PIPING.
PIPING GENERAL NOTES
1. CONTRACTOR TO COORDINATE ALL PIPE
ROUTING WITH OWNER BEFORE INSTALLING.
file no.
checked by drawn by consultant issue date contract order no.
472LCFMaintProj consultant job no.
18344.00
M a tr ix
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
472/18414.SMD
CD SET 04.26.19
funding code sheet description
N BASEMENT FLOOR PLAN - PIPING NEW
SCALE: 1/4" = 1'-0"
0 1 5 10
M-400
BRH
CAT
BASEMENT FLOOR PLAN -
PIPING NEW
AutoCAD SHX Text
UP
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E. CESAR E. CHAVEZ AVE
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
LAKELAND CORRECTIONAL FACILITY
AutoCAD SHX Text
COLDWATER, MICHIGAN
AutoCAD SHX Text 18344.00
AutoCAD SHX Text
141 1ST STREET
| A000-1834400-A-000 |
| M100-1834400-M-100 |
| M301-1834400-M-301 |
| M302-1834400-M302 |
| M303-1834400-M303 |
File details come from the government source that posted it. Updated .