Drawing.pdf
PDF 13 MB Posted
- Solicitation number
- W90VN924R0033
About this file
This document provides details on a federal contract opportunity to repair the roof and exterior wall of Building 139 located at Camp Carroll in South Korea. The solicitation number for this opportunity is W90VN924R0033 and is being issued by the Department of the Army Materiel Command Army Contracting Command. Interested parties should review the attached Drawing.pdf file and solicitation for additional scope of work requirements. The contract will require repair of both the roof and exterior wall at the specified building location. No further information is provided on response dates, pricing terms, or other contractual requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W90VN924R0033.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
R-11SHEET OF
DESIGNED BY
CHECKED BY
SUBMITTED BY
APPROVED BY
PROJECT NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
O & M
HOUSING DIV.
REVIEWED BY
UNITED STATES ARMY GARRISON DAEGU
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
DIRECTORATE OF PUBLIC WORK
HGFEDCBA
D - 23 - 33
CHON, HYON TAE
DESIGN REVIEW SIGNATURE
ORGANIZATION
USING AGENCY
36TH SIGNAL
MASTER PLN.
ENVIRONMENTAL
NAME SIGNATURE
O&M DIV.
FIRE DEPT.
SAFETY OFFICE
DPTMS(AT/FP)
188TH MP COM.
IND. HYGENIST
UNIT #15746, APO AP 96218-5746
DRAWING NO.
CHIEF,
DESIGN & TECH. REVIEW Br.
AS SHOWN
1 1 OF 1R - 1
T I T L E S H E E T
TITLE SHEET
USING AGENCY
DATE:17 JUL 23
HR-00513-9J
CAMP CARROLL
CIVIL
PROJECT NO. HR-00513-9J, CAMP CARROLL
ARCHITECTURAL
A001
A002
REPAIR ROOF AND EXTERIOR WALL AT B139
REPAIR ROOF AND EXTERIOR WALL AT B139
33 32 OF 33
25 24 OF 33
24 23 OF 33
23 22 OF 33
11 10 OF 33
10 9 OF 33
9 8 OF 33
34 33 OF 33
A003
A004
A101
A102
A103
A104
A105
A106
A107
A108
A201
A202
A203
A204
A301
A302
A303
A304
A305
A306
A307
A308
A309
A310
A311
A312
A313
A314
A401
A402
A403
NEW 1ST FLOOR PLAN
INTERIOR FINISH SCHEDULE, EXTERIOR FINISH SCHEDULE, GENERAL NOTES
WINDOW DETAILS, SEMI-EXPOSED GRID ACOUSTICAL, TILE CEILING DETAILS
WINDOW SCHEDULE, WINDOW TYPES, TYP SILL PAN FLASHING DETAIL
ROOF DETAILS - 5
ROOF DETAILS - 4
ROOF DETAILS - 3
ROOF DETAILS - 2
ROOF DETAILS - 1
CANOPY SECTION & DETAILS
CANOPY DETAILS
EXTERIOR WALL SECTIONS - 7
EXTERIOR WALL SECTIONS - 6
EXTERIOR WALL SECTIONS - 5
EXTERIOR WALL SECTIONS - 4
EXTERIOR WALL SECTIONS - 3
EXTERIOR WALL SECTIONS - 2
EXTERIOR WALL SECTIONS - 1
EXTERIOR WALL PLAN - 2
EXTERIOR WALL PLAN - 1
NORTH ELEVATION / WEST ELEVATION
SOUTH ELEVATION / EAST ELEVATION
ROOF EXIST / REMOVAL FLOOR PLAN
3RD EXIST / REMOVAL FLOOR PLAN
2ND EXIST / REMOVAL FLOOR PLAN
1ST EXIST / REMOVAL FLOOR PLAN
OVEROLL SITE PLAN, EQUIPMENT SCREEN ELEVATIONS
GENERAL NOTES, SCOPE OF WORK, SCOPE OF WORK FOR TYPE
ABBREVIATIONS, MATERIAL INDICATIONS AND SYMBOLS
GENERAL NOTES, SPECIFIC NOTES, MATERIAL NOTES
NEW ROOF PLAN
NEW 3RD FLOOR PLAN
NEW 2ND FLOOR PLAN
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
1.
2.
3.
6.
OF CONSTRUCTION SHALL BE USED.
NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE
EXISTING UTILITIES AS A RESULT OF HIS/HER WORK.
OF CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL PAY FOR ALL DAMAGES TO
TO UTILITIES. NOTIFY THE OWNER’S REPRESENTATIVE OF ANY UNDERGROUND UTILITIES IN THE WAY
EXTREME CAUTION AND MUST EXERCISE PROPER CARE DURING EXCAVATION TO PREVENT DAMAGE
ACCURACY OR THE EXISTENCE OF OTHER OBSTACLES WHICH MAY BE ENCOUNTERED WORK WITH
PLANS ARE FROM THE LATEST AVAILABLE RECORDS BUT ARE NOT GUARANTEED AS TO THE
THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITIES AND STRUCTURES AS SHOWN ON THESE
4.
LOCATIONS AND DEPTHS PRIOR TO EXCAVATION FOR THE NEW LINES.
CONTRACTOR SHALL EXPOSE THE EXISTING LINES AT THE PROPOSED CONNECTIONS TO VERIFY THEIR
WHEREVER CONNECTIONS OF NEW UTILITIES TO EXISTING UTILITIES ARE SHOWN ON THE PLANS, THE
THE PROJECT AREA PRIOR TO EXCAVATING. THE CONTRACTOR SHALL COORDINATE ALL WORK.
THE CONTRACTOR SHALL NOTIFY ALL AGENCIES TO VERIFY THE ACTUAL LOCATION OF ALL UTILITIES IN
5.
ADDITIONAL COSTS TO THE OWNER.
SCHEDULED TO REMAIN DURING THE CONSTRUCTION PERIOD WHICH SHALL BE REPAIRED AT NO
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES INCURRED TO EXISTING WORK
7.
PATCHING SHALL MATCH THE FINISH OF THE ADJACENT SURFACES.
THE CONTRACTOR SHALL PATCH ALL SURFACES EXPOSED FROM CUTTING, AND/OR REMOVAL WORK.
8.
ACCESSIBILITY GUIDELINES (ADAAG).
ALL STANDARDS, REQUIREMENTS AND GUIDELINES OF THE AMERICANS WITH DISABILITIES ACT
ALL GOVERNING AGENCIES. THIS WORK SHALL BE DESIGNED AND CONSTRUCTED TO CONFORM WITH
ALL WORK SHALL CONFORM TO ALL APPLICABLE LAWS, CODES, REGULATIONS, AND ORDINANCES OF
9. ALL DIMENSIONS SHOWN ON FLOOR PLAN ARE TO FACE OF FINISH, UNLESS OTHERWISE.
10.
PROVIDE DUST CONTROL MEASURES AS REQUIRED.
CLEAN AND FREE FROM ACCUMULATION OF WASTE MATERIALS AND RUBBISH. CONTRACTOR SHALL
AREA, THE OWNER’S PREMISES, INCLUDING STREETS AND OTHER AREAS USED BY THE CONTRACTOR
CONTRACTOR SHALL, AT ALL TIMES, DURING THE COURSE OF THE WORK, KEEP THE CONSTRUCTION
11.
OF OPERATIONS, INTERRUPTION OF MECHANICAL AND ELECTRICAL UTILITIES.
DELIVERY ACCESS TO AND FROM WORK, SPECIAL NOISY OPERATIONS, TIMING OF WORK, SEQUENCE
COORDINATE ALL OPERATIONS WITH THE OWNER’S REPRESENTATIVE FOR MATERIALS STORAGE,
12.
DEBRIS, RUBBISH, AND CONSTRUCTION MATERIAL AT TIME OF FINAL ACCEPTANCE.
REMOVE BARRICADE AFTER COMPLETION OF THE PROJECT AND CLEAN THE PROJECT AREA OF ALL
PREVENT PEOPLE FROM ENTERING THE PROJECT AREA AND TO PROTECT THE ENCLOSED PROPERTY.
CONTRACTOR SHALL PROVIDE BARRICADES, AS REQUIRED, AND ACCEPTABLE TO THE OWNER TO
13.
REPRESENTATIVE.
TRADE SHALL BE USED TO RESOLVE SUCH DISCREPANCIES AND MUST BE APPROVED BY THE OWNER’S
SUBMIT SHOP DRAWINGS ON HOW THEY WILL RESOLVE SUCH DISCREPANCIES. GENERAL PRACTICE OF
SHALL BE BORNE BY THE CONTRACTOR AND IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO
QUESTIONS RAISED DURING CONSTRUCTION PHASE THAT MAY RESULT IN EXTRA COST, SAID COST
ALL DISCREPANCIES FOUND ON DRAWINGS DURING CONSTRUCTION PHASE, ANY DISCREPANCIES OR
IT SHALL BE CONTRACTOR’S RESPONSIBILITY TO NOTIFY THE OWNER’S REPRESENTATIVE FOR ANY OR
14. CONTRACTORS SHALL VERIFY ALL QUANTITIES.
STATE PROPERTY IN ACCORDANCE WITH ALL LOCAL GOVERNING LAWS AND REGULATIONS.
BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF OUTSIDE THE LIMITS OF
ALL MATERIALS REQUIRED TO BE DISPOSED OF IN THIS PROJECT UNLESS REQUIRED TO BE SALVAGED, INTENDED TO LIMIT THE WORK REQUIRED IN ANY WAY.
TITLES, CAPTIONS, HEADINGS, ETC. ARE INTENDED FOR GENERAL REFERENCE AND ARE NOT
THE ABOVE NOTES APPLY TO THE FULL SET OF CONSTRUCTION DOCUMENTS.
1.
2.
3.
4.
GENERAL NOTES
OFFICER.
ANY DISCREPANCIES SHALL BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE CONTRACTING
PRIOR TO COMMENCING ANY CONSTRUCTION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION AND DIMENSIONS
THE CONTRACTING OFFICER.
AREAS CAUSED BY THIS PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AS DIRECTED BY
THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING
TRAFFIC AND OPERATIONS.
NECESSARY PRECAUTIONS FOR THE PROTECTION AND SAFETY OF THE PUBLIC AND/OR MILITARY
BARRICADES, MARKERS, CONES AND OTHER PROTECTIVE FACILITIES AND SHALL TAKE ALL
THE CONTRACTOR SHALL PROVIDE, INSTALL, AND MAINTAIN ALL NECESSARY SIGNS, LIGHTS, FLARES, CONTRACTOR.
INCURRED FOR SPILL CONTAINMENT AND CLEAN-UP SHALL BE THE RESPONSIBILITY OF THE
OFFICER SHALL OVERSEE THE CLEAN-UP EFFORT AND RENDER THE SITE CLEAN. ALL COSTS
APPROPRIATE MEASURES TO CONTAIN AND ADEQUATELY CLEAN-UP THE SPILL. THE CONTRACTING
CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER AND UTILIZE
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY SEWAGE SPILLS CAUSED DURING
WORK.
OF THIS WORK MUST BE DONE TO INSURE ROUGH-IN WORK IS ACCOMPLISHED PRIOR TO FINISHING
REPLACEMENT OF MECHANICAL, ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM COORDINATION
CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING TO MAKE WAY FOR THE INSTALLATION AND
INCONVENIENCE TO THE CUSTOMER’S MISSION OPERATION.
APPROVAL FROM THE GOVERNMENT AND EXECUTE WORK STAGE BY STAGE WITHOUT ANY
THE CONTRACTOR SHALL SUBMIT WORK SCHEDULE PRIOR TO COMMENCING THE WORK AND GET
CONTRACTOR.
THAT MAY OCCUR DURING THE COURSE OF HIS WORK SHALL BE RESTORED AT THE EXPENSE OF THE
THE CONTRACTOR SHALL TAKE MEASURES TO PROTECT EXISTING FACILITIES AND ANY DAMAGES
MATCHING EXISTING COLOR AND FINISH.
ANY STRUCTURAL STEEL MEMBERS EXPOSED TO INTERIOR SPACE SHALL BE RE-PAINTED WITH
CONTRACTING OFFICER AT THE LOCATION INDICATED BY CONTRACTING OFFICER.
SALVAGEABLE MATERIALS SHALL BE REMOVED FROM WORK SITE IN A MANNER AND TURNED OVER TO
1.
2.
3.
4.
CONDITIONS AND SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.
SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD
SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS.
15. FILL EXISTING DUCT AND PIPE HOLE W/ CONCRETE.
16.
RESPONSIBLE FOR REPAIR OR REPLACEMENT OF ACCESS DOOR AND WALL.
THE CONTRACTOR SHALL VERIFY THE NEW EQUIPMENT ACCESS CONDITIONS AT JOB SITE AND WILL BE
17.
18.
19.
AND SPECIFIC NOTES ON THE CONTRACT DRAWINGS.
THE CONTRACTOR SHALL FOLLOW THE CONSTRUCTION WORK AS INDICATED ON THE GENERAL NOTES
20.
CONTRACTOR SHALL SUBMIT ALL MATERIAL & COLOR SAMPLES TO DPW FOR APPROVAL.
COLOR AND PATTERN WHICH MANUFACTURERS STANDARD MUST APPROACH.
MATCH FOR MANUFACTURER COLOR IS NOT REQUIRED. THE SELECTIONS SERVE ONLY TO INDICATE
NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE MANUFACTURERS INDICATED. AN EXACT
COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR IDENTIFICATION PURPOSES ONLY, AND
CONTRACT DRAWING.
THE CONTRACTING OFFICER. A SHOP DRAWING SHALL NOT BE THE EXACT DUPLICATION OF THE
CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL TO
5.
INSTALLATION.
DETAILS AND DRAWING SHALL BE APPROVED BY THE C.O. OR HIS COR. BEFORE FABRICATION AND
INSTRUCTIONS. THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR AND WINDOW
ALL DOORS AND WINDOWS SHALL BE FABRICATED I.A.W. SPECIFICATIONS AND MANUFACTURER’S
CONTRACT.
ACCOMPLISH THE ARCHITECTURAL SCOPE OF WORK AT NO ADDITIONAL COST TO THE PROJECT
AGENCY, KOREA REGION OFFICE" FROM A PART OF THIS PROJECT. THE DETAILS WILL BE UTILIZED TO
PROJECTS, KOREA, NOVEMBER 30, 2015, DEPARTMENT OF THE ARMY INSTALLATION MANAGEMENT
THE ARCHITECTURAL STANDARD DRAWINGS SHOWN IN THE "STANDARD DETAIL DRAWINGS FOR O&MA 5.
6. REMOVE & CLEAN EXISTING FINISH MATERIAL & ADHESIVE BY GRINDING TO RECEIVE VCT & TILE.
7. REMOVE & CLEAN EXISTING PAINT BY SAND PAPER/ GRINDING FOR NEW PAINTING AND COATING.
8.
FREE.
SHEET (MSDS), WRITTEN IN ENGLISH, FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD
OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE A CERTIFICATE OR MATERIAL SAFETY DATA
LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON-VOLATILE SOLIDS) DURING THE EXECUTION
THE CONTRACTOR IS REQUIRED TO USE "LEAD FREE" COATINGS (LIQUID PAINTS OR COATINGS WITH
9.
AND USER.
THE CONTRACTOR SHALL COORDINATE ALL PHASES OF WORK WITH THE CONTRACTING OFFICER
REQUIREMENTS MANUAL EM 385-1-1 LATEST EDITION.
THE CONTRACTOR SHALL PERFORM ALL WORKS IN ACCORDANCE WITH USACE SAFETY AND HEALTH
AND THE ENVIRONMENTAL GOVERNING STANDARDS FOR KOREA, USFK REGULATION 201-1.
ALL DISPOSAL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE KOREAN ENVIRONMENTAL LAWS
CONTRACT, AND SHALL BE RESOLVED BEFORE PROCEEDING WITH THE WORK.
OMISSIONS OR CONFLICTS WHICH PREVENT HIM OR HER FROM FULFILLING THE TERMS OF THE
CONTRACTOR SHALL PROMPTLY NOTIFY THE OWNER’S REPRESENTATIVE OF ANY DISCREPANCIES, WITH THE REQUIRED WORK.
SHALL VERIFY ALL CONDITIONS AND DIMENSIONS RELATING TO THE PROJECT BEFORE COMMENCING
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND
WITHOUT WRITTEN APPROVAL OF THE OWNER’S REPRESENTATIVE.
THAT THE PROPER REVISIONS MAY BE MADE. MODIFICATION OF DETAILS SHALL NOT BE MADE
CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE OWNER’S REPRESENTATIVE SO
BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS
ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE
6.
7.
8.
9.
10.
11.
12.
13.
SPECIFIC NOTES MATERIAL NOTES
THROUGH COR.
NEW SURVEY REPORT AND ASBESTOS REMOVAL DOCUMENTATION TO ENVIRONMENTAL OFFICE
THE KOREA ENVIRONMENTAL GOVERNING STANDARD (KEGS). THE CONTRACTOR SHALL PROVIDE THE
PRIOR TO ANY WORK TO ASSURE THAT APPROPRIATE ASBESTOS CONTROL IS IN ACCORDANCE WITH
THE WORK AREA WILL NEED TO BE RESURVEYED AND ASBESTOS MATERIALS SHOULD BE REMOVED
CONTRACTOR SHALL CASE WORK IN THE AFFECTED AREA AND NOTIFY THE CONTRACTING OFFICER.
WORK. HOWEVER, IF SUSPECTED ASBESTOS CONTAINING MATERIAL ARE DISCOVERED, THE
FREE. TESTS HAVE INDICATED THAT ASBESTOS IS NOT PRESENT IN THE AREA AFFECTED BY THIS
OR MSDS, WRITTEN IN ENGLISH, FROM THE MANUFACTURER VERIFYING THE PRODUCT IS ASBESTOS
WEIGHT) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE A CERTIFICATE
THE CONTRACTOR IS REQUIRED TO USE "ASBESTOS FREE" MATERIALS (LESS THAN 1 PERCENT BY
A001
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
MATERIAL NOTES
SPECIFIC NOTES
GENERAL NOTES
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
D - 23 - 33
1 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
A
AMPERE
AT
ANCHOR BOLT
DROP, DEW POINT,
FD FLOOR DRAIN
NATIONAL ELECTRICAL
TOP OF STEELT.O.S.
NEMA
CEMENT PLASTER
DOWNSPOUT
DRAIN MANHOLE
DOUBLE POLE SINGLE THROW
DIVISION
DRINKING WATER DISPENSER
DRAWING(S)
DWELLING
CARPET
M A T E R I A L I N D I C A T I O N S A N D S Y M B O L S
DESIGN PACKAGE
DRINKING FOUNTAIN
DETAIL(S)
DIAMETER
DIAGRAM
DIMENSION
DISTRIBUTION
DAYLIGHT, DEAD LOAD
DRAWING LIST, DRAIN LINE
DROP MANHOLE
DRAIN OR DOOR
DOWN
DRY BULB
CAST STEEL
DESIGN
DOOR STOOP
DOUBLE
DISCONNECT
CORRIDOR
CORNER
CURVE
CEMENT PLASTER CEILING
CONCRETE PIERCING
CONTRACTION JOINT
COATING, CUTTING
CUBIC FOOT
COLD WATER
CORRUGATED THRESHOLD
CAPILLARY WATER BARRIER
CHECK VALVE
CPL
DS
DMH
DPST
DIV
AWP ACOUSTICAL WALL PANEL
ATT ASPHALT TIRE TILE
DWD
CAT CATALOG
DWG(S)
DWEL
BB BULLETIN BOARD
CPT
& RADIALOGICAL
CBR CHEMICAL BIOLOGICAL
DIAG
DF
DB
DET(S)
DIM
DISTR
DL
DMA
DN
DP
DR
BREAKERBRKR
DSGN
DST
DBL
DISC
CENTER TO CENTERC TO C
COR
CORR
CPC
CRV
CP
CS
CTG
CUFT
CTRJ
CONDUIT
CW
C
CAPACITYCAP
CT
CWB
CV
AVERAGE
ASSEMBLYASSY
AVG
BELL & SPIGOT
BARRIER
BOTTOM CHORD
BOARD
BOLT CIRCLE
BARR
B & S
BD
BC
BELL END
BOILER FEED WATER
BOILER HORSE POWER
BOILER HOUSE
BFW
BE
BH
BHP
BLOCKING
BUILDING(S)
BLOW-OFF
BOTTOM
BLDG(S)
BLKG
BOT
BO
BKS BARRACKS
BRICK
BASE PLATE, BRICK PAVER
BRITISH THERMAL UNITS
BRITISH THERMAL UNITS
BOTH SIDES
BP
BRK
BTU
BTUH
BS
BULL NOSE BLOCK
PER HOUR
BN
ANGLE STOP VALVE
ACOUSTIC TILE CEILING
AMPERE TRIP
AUTOMATIC
AMERICAN WIRE GAGE
AMERICAN SOCIETY FOR
TESTING & MATERIAL
ATC
AT
ASV
AUTO
AWG
ASTM
GCWT GLAZED CERAMIC WALL TILE
LL LIVE LOAD
LB POUND
LINEAR FEETLF
PAV, PVMT PAVEMENT
WALL PANEL
SOUND ABSORPTIONSAWP
LVL LEVEL
RETURN AIR REGISTER
REPAIR
RUBBER TILE
RIVET
RAW WATER
RIDGE VENT
SI SURFACE INLET
WALK-OFF MATMAT
SOAP DISPENER
RS RUBBER SHEET
RP RUBBER PAD
LC LAVATORY COUNTERTOP
RF RUBBER FLOORING
PCC
POL
POC
PG
PEJ
PRESS GAGE
POINT OF CONNECTION
PETROLEUM, OIL & LUBRICANT
PORTLAND CEMENT CONCRETE
PREMOLDED EXPANSION JOINT
RG
REF
RECT
REPL
RELOC
REV
RM
RPM
RHWS
RHMS
RL
RO
REINF
RET
REFL
RFT
REFR
REQ’D
REFRIGERATOR
REFLECTED
RETAINING
REINFORCEMENT
RUBBER FABRIC TITLE
ROOF LINER
ROUGH OPENING
ROUND HEAD WOOD SCREW
ROUND HEAD METAL SCREW
RV
RW
RVT
RT
REVOLUTIONS/ MINUTE
REQUIRED
ROOM
RPR
REVIEW, REVISE
REPLACE
RELOCATED
RECTANGULAR
REFERENCE
RR
RETURN AIR GRILLE
PLATE, PLASTIC LAMINATEPL
FLUOR
FDN
FED
FHY
FL
FDR
FRAME
FIXTURE
FIXED
FOOT, FLOOR TILE
FR
FS
FXTR
FXD
FPM
FHMS
FT
FINISH
FREEZER
FRAMING
FY
FNSH
FF
FRZA
FE
FOS
FOR
FEC
FRAMG
FHWS
FIRE DOOR
FEDERAL, FAR EAST DISTRICT
FOUNDATION
FLUORESCENT
FUEL OIL SUPPLY
FUEL OIL RETURN
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FLOOR, FACTORY FINISH
FAR SIDE, FULL SIZE
FLOOR OR FLOOR LINE
FLASHING, FLUSH
FIRE HYDRANT
FISCAL YEAR
FLAT HEAD WOOD SCREW
FEET PER MINUTE
FLAT HEAD METAL SCREW
GAGE
GALLON
GROUND
G
GA
GAL
GALV
GL
GND
GEN
GFM(M)
GSS
GTV
GSP GALVANIZED STEEL PIPE
GALVANIZED STEEL SHEET
GATE VALVE
GRADE LINE
PROPERTY (MATERIAL)
GOVERNMENT FURNISHED
GALVANIZE
GENERATOR
GIRDER, GLASS
SIMILAR
SLOPE
SIM
SLP
SP
SDL
SHLDR
SH
SECT
SADDLE
STATIC PRESSURE
SECTION
SHOWER HEAD OR SHEET
SHOULDER
SOLV
SPEC(S)
SPDT
SPM
SPH
SOLENOID VALVE
DOUBLE-THROW
SINGLE-POLE
STROKES PER MINUTE
SPACE HEATER
SPECIFICATION(S)
STAIR NOSINGSN
INLETINL
INSULATION
ISOLATION JOINT
INVERT
INTERIOR
INSECT SCREEN
INCANDESCENT
IDENTIFICATION
INSUL
IJ
INVT
INTR
IS
INCAND
IDENT
INSTALLATIONINSTL
STORAGESTOR
MANUFACTURERS ASSOCIATION
MATERIAL
NUMBER
NOMENCLATURE
NOT IN CONTRACT
NOT TO SCALE
OUT TO OUT
OVERALL
NON FROST SUSCEPTIBLE
SPLITTER DAMPER
SUPPLY AIR GRILLE
SEWER MANHOLE
SEWER LINE
SCHEDULE
SINGLE KEYED DIFFERENT
SD
SG
SMH
SL
SKD
SCHED
ON CENTER
OCTAGON
OVERHEAD
OVERLOAD
ORIGINAL
OPTIONAL
OUTLET
OUTSIDE DIAMETER
OPENING
PILE CAP
POLE, PLATE, PAPER
POST INDICATOR VALVE
PUSH BUTTON
POWER DRIVEN
PEDESTAL
SCREEN DOOR
SCALE
SELECTOR
SCD
SC
SEL
SCREW
SIDINGSDG
SCR
PHASE
PLASTER
PLYWOOD
PANEL
PLUSE POSITION MODULATION
PAINT
PERMANENT
NO OR #
NOMEN
NIC
NTS
O TO O
OA
NFSM
INCH
INCLUDE
IN
INCL
JOINT
JOIST
J
JT
KILOWATT
KILOWATT HOUR
KOREAN STANDARD
KILOVOLT AMPERE
KWH
KW
KS
KVA
OC
OCT
OL
O/H
ORIG
OPTL
OD
OUT
OPNG
P
PC
PIV
PB
PDVN
PED
LONG
LAVATORY
LIGHTING ARRESTER
L
LA
LAV
LINTEL
LONGITUDINAL
LATTICE
LNTL
LTC
LONG
LG LENGTH
LAYOUT
LOUVERED DOOR
LEAVING
LVD
LTY
LVG
LIGHTING
LATCHING THRESHOLD
LOWER PRESSURE SODIUM
LT
LTG
LPS PLAS
PH
PNL
PLYWD
PPM
PNT
MAINTENANCE & REPAIR
MACHINE
M & R
MACH
PERM
GALLON PER MINUTE
GENERAL
GPM
GENL
WL WATER LINE
PORTER
VINYLE COVERED WALL PADDING VWP
VST VINYL SHEET TILE
VSF VINYL SHEET FLOORING
URINAL SCREENUS
TOILET TISSUE DISPENSERTTD
TUFV TOUCHLESS URINAL
FLUSH VALVE
VRB VENT RUBBER BASE
WOOD FLOORINGWF
WATER
WALL FOOTING
WM
W/O
WP
WT
WTR
WWF
WF
WIRE MESH
WITHOUT
WORKING POINT
WEIGHT
WELDED WIRE FABRIC
WLB WALL BOARD
WATER LINE OR WALL
W
WA
W/
WCR
WDO
WH
WL
WD
WB
WC
WATT
WAINSCOT
WOOD BASE, WET BULB
WATER CLOSET, WALL COVERING
WATER COOLER
WITH
WIDTH OR WOOD
WINDOW
WALL HYDRANT
WIND LOAD
VINYL COVE BASE
VAR
VCB
VTR VENT THROUGH ROOF
VARIOUS
VEST
VOL
VESTIBULE
VOLUME
VELOCITY
VINYL COMPOSITION TILE
VERTICAL
VENTILATOR
VITRIFIED CLAY TILE,
VEL
VERT
VENT
VCT
VALVE BOX, VAPOR BARRIER
VACUUM
VOLT
VB
VAC
V
UNIFORM
UNIT HEATER
"U" SHAPED STIRRUP
URINALUR
U
UH
UNIF
UNDERWRITERS LABORATORIES
AND
THREE WAY
SAME AS ABOVE, DITTO"
3 WAY
UL
UGND UNDER GROUND
TELEVISION TURNING VANES
TOTAL
TYPICAL
TILE WAINSCOT
TOT
TV
TYP
TW
CONTAMINATION CONTROL AREA
CONTINUOUS
COLUMN FOOTING
WATER (RETURN)
CMU CONTROL JOINT
CAST IRON PIPE
CAST IRON
CENTER LINE
CONTROL JOINT
CAULKING
COLOR, CLEAR
CEILING, COOLING
CHILLED DRINKING
CUBIC FEET PER MINUTE
CLEAR WIRE GLASS
CERAMIC MOSAIC TILE
CORRUGATED METAL PIPE
CONCRETE
COLUMN
CONNECTION
CONSTANT
CONCRETE MASONRY UNIT
CEILING DIFFUSER
CHANNEL
CEILING HEIGHT
CATCH BASIN
CIRCUIT
ACST ACOUSTICAL TILE
BAFFLE PANEL
AHBP ACOUSTICAL HANGING
CCA
CONT
CF
CIP
CJ
CI
CLJ
CLR
CLKG
CLG
CDW(R)
CLWR
CFM
CMP
CMT
COL
CONC
CONST
CONN
CMU
CD
CHAN
CH
CB
CKT
ASPHALTIC CONCRETEAC
ACCESS PANEL
ABOVE TILE FINISHED FLOOR
AP
AFF
ACCESS ACCESSORY
ASBESTOS CEMENT BOARD
ACCESS
AREA DRAIN
AIRCRAFT
ADJACENT
ADHESIVE
ALUMINUM
ANCHOR
AIR HOUSE POWER
AIR CONDITIONING
APPENDIX
ALTERNATE
APPROXIMATE
ARCHITECTURE
A
ASPHALT
AS SOON AS POSSIBLE
AIR EXTRACTOR
A
ASPH
ASAP
AE
ADJ
AHP
AL
APPROX
APPX
ALT
ARCH
AHR
ACFT
ACS
ADH
AD
A/C
ACB
AB
V TERBBA
FINISH SYSTEM
EIFS EXTERIOR INSULATION & HDR HARDENER
PT PAVER TILE
MOPR
PTDWR PAPER TOWEL DISPENSER
W/ RECEPTACLE
MOP RACK
METAL ROOF LINERMRL
MIRROR GLASSMG
H/C HANDICAP
PWR
PSI
PRV
PRESS
PSIG
PROV
PROT
PSF
POWER
PRESSURE
PRESSURE REDUCING VALVE
POUNDS/ SQUARE INCH
POUNDS/ SQUARE INCH GAGE
PROVIDE
PROTECTION
POUNDS/ SQUARE FOOT
QTY
QT
QTF
R
RAD
RBR
RC
RCP
RCPT
RE-BAR
RD ROAD
REINFORCED CONCRETE PIPE
RECEPTACLE
REINFORCING BAR
RUBBER
REINFORCED CONCRETE
RADIUS
RAIL, RIGHT
QUARRY TILE
QUARRY TILE FLOOR
QUANTITY
EACH
EXISTING
EXT
EDR
EA
EXST
ENCL
EST
EP
EXH
ESP
ENT
EXP JT
ENGRG
EL, ELEV
EXPANSION JOINT
ENTERING, ENTRANCE
ESTIMATE
EXHAUST
EQUIVALENT DIRECT RADIATION
EXPLOSION PROOF
ENGINEERING
ELEVATION
ENCLOSURE
EXTERIOR
EXTERNAL STATIC PRESSURE
ELEC
ETC
EW
EWC
EMER
FABL
FACTOR
FC
FAC
FCO
F
EACH WAY
FIRE ALARM BELL
FUSE CUTOUT
EMERGENCY
ELECTRICAL
ELECTRIC WATER COOLER
ETCETERA
FLOOR CLEAN OUT
DEGREE FAHRENHEIT
EVAP EVAPORATING
GWT
GWB GYPSUM WALL BOARD
GLAZED WALL TILE
HIGH PRESSURE SODIUM
HIGH POWER FACTOR
INDIRECT DRAIN
INSIDE DIAMETER
HPS
HPF
ID
IN ACCORDANCE WITHIAW
NATIONAL ELECTRICAL CODE
PROJECT
PROOF
PREFABRICATED
PARTITION
NEC
PROJ
PRF
PREFAB
PTN
MILES PER HOURMPH
MAXIMUM
MIDDLE, MODULE
MECHANICAL
MAGNETIC CONTACTOR
MAX
MDL
MECH
MC
MATL MATERIAL
METAL DOOR
METAL
MINIMUM
MEZZANINE
METD
MET
MIN
MEZZ
MACHINE SCREW
METAL THRESHOLD
BRITISH THERMAL UNITS
MOUNTING
MSCR
MT
MBH
MTG
MISC MISCELLANEOUS
METAL SCREW
MACHINE BOLT
MIRROR
MASONRY OPENING
MS
MB
MR
MO
MILLIMETER
MANUFACTURE
MM
MFR
PER HOUR (THOUSANDS)
HIGH, HEAD, HORIZONTAL
HOSE BIBB
HARD DRAWN BARE COPPER
HARDWARE
HEIGHT
HOLLOW METAL
HERTZ
HORSE POWER
HEATER
HARD BOARD
HARDWOOD
HOT WATER
HOUR
HEATING AND VENTILATION
HORIZONTAL
HEXAGON
HB
H
HDBC
HDW
HM
HGT
HP
HZ
HTR
HDBD
HDWD
HW
HR
HORIZ, HOR
H/V
HEX
N SOII A
TELECOMMUNICATIONTELECOMM
SPST SINGLE-POLE
STEEL SHEET OR
STAINLESS STEEL
SERVICE SINK
STATION
STEEL
STRUCTURAL
STANDARD
STAIRWAY
SWITCH
SAFETY VALVE
SUSPENDED
SELF-TAPPING
SS
SST
STA
STL
STRL
STD
STWY
SW
SV
SUSP
ST
SYSTEM
SUPPLY AIR REGISTER
STIFFENER
STORAGE
TITLE BLOCK
TELEPHONE
TERRA COTTA
THICKNESS
TEMPORARY OR TEMPERATURE
SYS
SR
STIFF
STOR
T/B
TC
TEL
THK
TEMP
THERMOMETER
TECHNICAL
TH
TECH
THRU THROUGH
DOOR NUMBER
WINDOW & LOUVER NUMBER
ROOM NUMBER
SINGLE DOOR
DOUBLE DOOR
DOUBLE ACTING DOOR-SINGLE
DOOR
DOUBLE ACTING DOOR-DOUBLE
DOOR
DOUBLE ACTING DOOR-IN
& DOOR-OUT
FOLDING DOOR OR FOLDING
PARTITION
SLIDING DOOR
POCKET DOOR
OVERHEAD COILING DOOR
WINDOW, DOUBLE HUNG
WINDOW, DOUBLE-OPENING OUT
WINDOW, SINGLE-OPENING OUT
WINDOW, HORIZONTAL-SLIDING
LOUVERED OPENING
D1
W1 L1
( A R C H I T E C T U R A L )
CL
A002
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
SYMBOLS
MATERIAL INDICATIONS AND
ABBREVIATIONS
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
2 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
REPAIR AND MAINTENANCE WORK
SCOPE OF WORK
ARCHITECTURAL
CAMP CARROLL
A003
PAINT INTERIOR WALL.
REPLACE EXISTING ACOUSTICAL CEILING TILE UNIT.
SCOPE OF WORK
PROTECTED METAL FASCIA WALL
FACADE CLADDING PANNEL WALL
TYPE
STEEL TUBE AND STEEL PIPE
CONC WALL, COLUMN, BEAM, BRACE,
1212EQUIPMENT SCREEN WALL
11 2 3 5 13
DOWNSPOUT AND FLASHING
PROTECTED METAL GUTTER, CONDUCT HEAD,
4 6ROOF, CANOPY
CEILING
WINDOW
E X T E
R
IO
R
IN
T E
R
IO
R 14
REMARKS
WALL
ROOM NO: 303 / 304 / 305 / 308 / 309
SCOPE OF WORK FOR TYPE
FINISH SCHEDULE
INTERIOR
SEE
A203 / 204
SEE SHEET
FINISH SCHEDULE
INTERIOR
SEE
SCHEDULE
SEE WINDOW
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
SCOPE OF WORK FOR TYPE
SCOPE OF WORK
GENERAL NOTES
INCLUDING NECESSARY ACCESSORIES.
REPLACE EXISTING PARAPET CAP FLASHING WITH ALUMINUM SHEET CAP FLASHING
REPLACE EXISTING STRUCTURAL STANDING SEAM METAL ROOFING WITH ROOF INSULATION.
REPLACE EXISTING WINDOW WITH NEW INCLUDING BLIND AND NECESSARY ACCESSORIES.
RECOAT EXISTING EXTERIOR PROTECTED METAL FASCIA WALL.
RECOAT EXTERIOR SURFACE.
PROVIDE CONCRETE SPLASH BLOCK.
REPLACE EXISTING VINYL COVE BASE WITH NEW.
ROOM NO: 303 / 304 / 305 / 308 / 309
16 REPLACE EXISTING PROTECTED METAL FLASHING WITH NEW INCLUDING NECESSARY ACCESSORIES.
INCLUDING NECESSARY ACCESSORIES.
REPLACE EXISTING FACADE CLADDING PANEL AND SUPPORT FRAME WITH NEW
FASCIA WALL WITH NEW INCLUDING AIR AND WATER RESISTIVE BARRIER AND NECESSARY ACCESSORIES.
REPLACE EXISTING INSULATION UNDER FACADE CLADDING PANEL AND PROTECTED METAL
AND NECESSARY ACCESSORIES.
REPLACE EXISTING RAIN GUTTER WITH NEW INCLUDING FLASHING
CANOPY - RESTORE PARTIALLY REMOVED BRICK FACE.
REPLACE EXISTING ALUMINUM SHEET PANEL AND FLASHING WITH NEW AT THE ENTRANCE
INCLUDING FLASHING AND NECESSARY ACCESSORIES.
REPLACE EXISTING RAIN GUTTER WITH STAINLESS STEEL RAIN GUTTER
BRIDGE AREA 1212
CONDUCT HEAD AND DOWNSPOUT INCLUDING NECESSARY ACCESSORIES.
REPLACE AND PROVIDE EXISTING CONDUCT HEAD AND DOWNSPOUT WITH STAINLESS STEEL
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
3 33
27800
57600
17550
7350 4900
3370034600
A
B
1 52 3 4 6 7 8 9 10 11
F
G
D
E
C
TO CENTER OF WALL
R=33528 TO
CENTER OF WALL
R=30000
TO EDGE OF CANOPY
DN
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
A SCALE : 1 / 50
R=33150
N
EQUIPMENT SCREEN
A004
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
TOP OF
STEEL BEAM
TOP OF CONC
TOP OF INT. GRAVELTOP OF CONC
TOP OF INT. GRAVEL
STEEL BEAM
TOP OF
2A
2B
A
OVERALL SITE PLAN
SCALE : 1 / 200004
A B
EQUIPMENT SCREEN ELEVATIONS
EQUIPMENT SCREEN ELEVATIONS
OVEROLL SITE PLAN
2A 2B
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
4 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
S L
O P
E
104106
STAIR-4
STAIR-2
STORAGE-2
UP
JAN
DN
INDOOR
OUTDOOR
ROOM
VEST-3
W TOILET
STORAGE-1
COMM ROOM
M TOILET
CORRIDOR-1
STAIR-3
MECH ROOM
PLATFORM
TOILET
DN
AV EQUIPMENT RM
ROOM
W DRESSINGM DRESSING
ROOM-2
CONCESSIONHALL
ROOM-1
MULTI-PURPOSE
VEST-1
ELEV
ROOM
MACH
PLATFORM
ELEC ROOM
STORAGE
COMMUNITY KITCHEN
AHU ROOM
VEST-2
PARTITION
FOLDING
STORAGE
116 120
VEST-4
VEST-5
134135
ELEC CLOSET
UP
ELEV
STAIR-1
UP
UP
UP
DN
KITCHEN
CORRIDOR-2
DN
DN
MULTI-PURPOSE
FUTURE
W1
20’-6"
18’-1"
19’-0"
16’-1"
27900
91’-6"
23’-9"
17550
57’-7"
57600
189’-0"
2 3 4 5 6 6.4 6.5 7 8 9 10 111
N
F
G
A
B
D
E
12’-4"
A SCALE : 1 / 100
1ST EXIST / REMOVAL FLOOR PLAN
REMOVAL FLOOR PLAN
1ST EXIST /
A101
EQUIPMENT SCREEN
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
1. REMOVE AND REINSTALL THE EXISTING EXTERIOR LIGHTING FIXTURES WITH
ALL NECESSARY ACCESSORIES ACCORDING TO WORK SCOPE.
2. REMOVE AND REINSTALL THE EXISTING SAFETY SWITCHES WITH ALL NECESSARY
ACCESSORIES ACCORDING TO WORK SCOPE.
3. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPLACE OR REPAIR ALL DAMAGES
TO EXISTING EQUIPMENT, PIPE, AND DUCT ACCORDING TO WORK SCOPE.
4. THE CONTRACTOR SHALL BE RESPONSIBLE TO REMOVE AND REINSTALL
THE OBSTRUCTED ITEMS SUCH EQUIPMENT, PIPE, AND DUCT TO MAKE WAY FOR
THE INSTALLATION AND REPLACEMENT OF WORK.
NOTES:
LEGEND
REMOVE STANDING SEAM METAL ROOFING
REMOVE METAL SHEET OF CANOPY
REMOVE ACOUSTICAL CEILING TILE UNIT
FRAME AND INSULATION
REMOVE FACADE CLADDING PANNEL WALL, SUPPORT
REMOVE INSULATION
REMOVE AND REINSTALL PROTECTED METAL FASCIA WALL
REMOVE PROTECTED METAL FLASHING
REMOVE EXISTING WINDOW
DOWNSPOUT AND CAP FLASHING PARAPET
GUTTER EXPANSION JOINT, METAL CONDUCT HEAD,
REMOVE PROTECTED METAL GUTTER,
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
5 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
VEST-1
HALL
GAME ROOM
BOSS ROOM
PROJECTION
ROOM
W TOILETM TOILET
COMM ROOM
CORRIDOR-2
OFFICE
STORAGE-1
JAN
ELEC ROOM
STORAGE-2
AHU ROOM
TOUR & TRAVEL
CENTER
DIRECTOR
OFFICE
UP
DN
STAIR-2
STAIR-4
STAIR-3
217216
MUSIC ROOM-2
MUSIC ROOM-1
NINTENDO &
PLAYSTATION
GAME ROOM
TV AREA
CORRIDOR-1
STAIR-1
ELEV
VEST-2
DN
UP
DN
COUNTER
UNUSED SPACE
212A
CLOSET
CCTV
UPDN
20’-6"
18’-1"
19’-0"
16’-1"
27900
91’-6"
23’-9"
17550
57’-7"
57600
189’-0"
2 3 4 5 6 6.4 6.5 7 8 9 10 111
N
F
G
A
B
D
E
BRIDGE
A102
A SCALE : 1 / 100102
2ND EXIST / REMOVAL FLOOR PLAN
NOTES:
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
REMOVAL FLOOR PLAN
2ND EXIST /
3. WHERE NEW WORK IS APPLIED TO EXISTING SURFACES, PERFORM REMOVALS
AND PATCHING IN A MANNER TO PRODUCE SURFACES SUITABLE FOR RECEIVING NEW
WORK FLUSH FINISHED SURFACES OF PATCHED AREA WITH ADJACENT EXISTING SURFACE.
4. VERIFY EXISTING CONDITIONS, INFORMATION, AND LOCATION OF OBJECTS CRITICAL
TO THE WORK PRIOR TO COMMENCING WORK.
5. FIELD VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS,AND SIZE / LOCATIONS OF
EXISTING STRUCTURAL ELEMENTS.
6. NO PENETRATIONS ARE ALLOWED IN EXISTING OR NEW BEAMS AND OR COLUMNS.
LEGEND
REMOVE STANDING SEAM METAL ROOFING
REMOVE METAL SHEET OF CANOPY
REMOVE ACOUSTICAL CEILING TILE UNIT
FRAME AND INSULATION
REMOVE FACADE CLADDING PANNEL WALL, SUPPORT
REMOVE INSULATION
REMOVE AND REINSTALL PROTECTED METAL FASCIA WALL
REMOVE PROTECTED METAL FLASHING
REMOVE EXISTING WINDOW
DOWNSPOUT AND CAP FLASHING PARAPET
GUTTER EXPANSION JOINT, METAL CONDUCT HEAD,
REMOVE PROTECTED METAL GUTTER,
1. EXISTING CONSTRUCTION FLOOR PLAN SHOWN BASED UPON FIELD ASSESSMENT.
ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITION TO BE
REPORTED TO THE CONTRACTING OFFICER PRIOR TO PROCEEDING WITH WORK.
2. DEMOLITION AND REPAIR WORK SCHEDULE MUST PERFORMED WITH "DUE CARE AND
DILIGENCE" IN ORDER TO PREVENT ARBITRARY DAMAGE OR INTERRUPTION OF SERVICE.
3. PARTIALLY REMOVE BRICK FACE FINISH FOR AL SHEET REPLACEMENT OF CANOPY
AS REQUIRED AND RESTORE BRICK FACE WALL.
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
6 33
FEC
CCTV
FEC
CHILDREN’S
M TOILET
PERIODICALS
OFFICE
STAFF
READING AREA
CD/DVD
ELEV
STAIR-1
DN
HALL
AHU ROOM
AREA
COMPUTER
COMM ROOM
DN UP
STAIR-2
W TOILET
311 312
VEST-1
JAN
CORRIDOR
ELEC ROOM
DN
STAIR-3
BRIDGE
20’-6"
18’-1"
19’-0"
16’-1"
27900
91’-6"
23’-9"
17550
57’-7"
57600
189’-0"
2 3 4 5 6 6.4 6.5 7 8 9 10 111
N
F
G
A
B
D
E
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
A103
A SCALE : 1 / 100103
3RD EXIST / REMOVAL FLOOR PLAN
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
REMOVAL FLOOR PLAN
3RD EXIST /
LEGEND
REMOVE STANDING SEAM METAL ROOFING
REMOVE METAL SHEET OF CANOPY
REMOVE ACOUSTICAL CEILING TILE UNIT
FRAME AND INSULATION
REMOVE FACADE CLADDING PANNEL WALL, SUPPORT
REMOVE INSULATION
REMOVE AND REINSTALL PROTECTED METAL FASCIA WALL
REMOVE PROTECTED METAL FLASHING
REMOVE EXISTING WINDOW
DOWNSPOUT AND CAP FLASHING PARAPET
GUTTER EXPANSION JOINT, METAL CONDUCT HEAD,
REMOVE PROTECTED METAL GUTTER,
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
7 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
DN
20’-6"
18’-1"
19’-0"
0"
29’-8"
23’-9"
17550
57’-7"
33850
111’-1"
2 3 4 5 6 6.4 6.5 71
N
F
G
A
B
D
E
A104
A SCALE : 1 / 100104
ROOF EXIST / REMOVAL FLOOR PLAN
S S
S S
S S
6432 51 6.4
B
A
C
D
E
F
G
S SSS S S S
STAIR-1
AREA
READING
STAIR-2
CORRIDOR-2
ELEC ROOM
STAIR-3
VEST-2
313 312
W TOILETM TOILET
HALL
AHU ROOM
AREA
CHILDREN’S
COMPUTER
OFFICE STAFF
PERODICALS
A 104
3RD FLOOR CEILING EXIST / REMOVAL PLAN2
SCALE : 1 / 200
TILE SHOULD BE REMAIN EXCEPT FOR L- BAR FACE TO WALL.
2. THE CEILING SUSPENSION FRAME FOR ACOUSTICAL CEILING
CEILING TILES TO THE GOVERNMENT PER DPW REQUIREMENTS.
3. THE CONTRACTOR SHALL RETURN DISASSEMBLED EXST ACOUSTICAL
REINSTALLED AS NECESSARY.
CEILING FRAME DURING WORK, AND COULD BE REMOVED AND
4. THE CONTRACTOR SHALL PREVENT DAMAGE TO THE EXISTING
NOTES:
REFER TO FLOOR PLAN AND FINISH SCHEDULE.
1. THE SCOPE OF All WORK IS APPLIED TO BUILDING PARTS.
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
REMOVAL FLOOR PLAN
ROOF EXIST /
LEGEND
REMOVE STANDING SEAM METAL ROOFING
REMOVE METAL SHEET OF CANOPY
REMOVE ACOUSTICAL CEILING TILE UNIT
FRAME AND INSULATION
REMOVE FACADE CLADDING PANNEL WALL, SUPPORT
REMOVE INSULATION
REMOVE AND REINSTALL PROTECTED METAL FASCIA WALL
REMOVE PROTECTED METAL FLASHING
REMOVE EXISTING WINDOW
DOWNSPOUT AND CAP FLASHING PARAPET
GUTTER EXPANSION JOINT, METAL CONDUCT HEAD,
REMOVE PROTECTED METAL GUTTER,
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
8 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
12’-4"
UP
DN
INDOOR
DN
PLATFORM
122 123
133 134
UP
FEC
FOR WALL
DASHED LINE
FEC
FEC
ELEV
UP
UP
UP
DN
(ABOVE)
DS
DS DS
DS DS
DS
DN
DN
SLOPE 2%
DS
S L O
P E
1/
20’-6"
18’-1"
19’-0"
16’-1"
27900
91’-6"
23’-9"
17550
57’-7"
57600
189’-0"
2 3 4 5 6 6.4 6.5 7 8 9 10 111
N
F
G
A
B
D
E
DASHED LINE FOR
BRIDGE (ABOVE)
SCALE : 1 / 100
NEW 1ST FLOOR PLAN1
A A105
1B
1B
1A
1B
1A
1A
1A
EQUIPMENT SCREEN
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
NEW 1ST FLOOR PLAN
773 10
773 10
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
9 33
GEJ (GUTTER EXPANSION
JOINT)-TYP
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
A SCALE : 1 / 100
NEW 2ND FLOOR PLAN
UP
DN
217216
209 208
SEAM METAL
DS
DASHED LINE FOR
ROOF (ABOVE)
ROOF SLOPE
DN
UP
DN
STANDING SEAM
METAL ROOFING
DS
DS
DSDS
DS DS DS
CURVED STANDING
SEAM METAL 1ST FLOOR
CANOPY (BELOW)
CURVED
2%
(ABOVE)
LINE FOR
WALL
DASHED
DS
212A
UPDN
20’-6"
18’-1"
19’-0"
16’-1"
27900
91’-6"
23’-9"
17550
57’-7"
57600
189’-0"
2 3 4 5 6 6.4 6.5 7 8 9 10 111
N
F
G
A
B
D
E
GEJ
PROTECTED METAL
DOWNSPOUT(TYP)
1B
METAL ROOFING
STANDING SEAM
A106
1E
(TYP)
CONC SPLASH BLOCK
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
NEW 2ND FLOOR PLAN
9 10
773 10
773 10
CURVED STANDING
EXST
ROOFING (TYP)
1B
9 103
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
10 33
DASHED LINE
FOR WALL
(BELOW)
DASHED LINE
FOR ROOF
(ABOVE)
DS DS
DS
CURVED STANDING
SEAM METAL CANOPY
DS
DASHED LINE FOR
ROOF (ABOVE)-TYP
CAP FLASHING
R O
O F
S L O
P E
DS
DN
DS
DN UP
DS
311 312
314 317
DN
R O
O F
S L O
P E
R O
O F
S L O
P E
R O
O F
S L O
P E
R O
O F
S L O
P E
R O
O F
S L O
P E
BRIDGE
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
20’-6"
18’-1"
19’-0"
16’-1"
27900
91’-6"
23’-9"
17550
57’-7"
57600
189’-0"
2 3 4 5 6 6.4 6.5 7 8 9 10 111
N
F
G
A
B
D
E
A SCALE : 1 / 100
NEW 3RD FLOOR PLAN
DS
DS
DS
A107
W1 W2
W2
3AL SHEET
C
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
NEW 3RD FLOOR PLAN
773 10
773 10
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
11 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
A SCALE : 1 / 100
DS
CURVED STANDING
SEAM METAL
ROOFING (TYP)
STANDING SEAM
METAL ROOFING (TYP)
CONDUCT HEAD
(TYP)STAIR-2
PROTECTED MET
FLASHING
STANDING SEAM
METAL ROOFING
(TYP)
CHIMNEY
DN
R O
O F
S L O
P E
P E
R
R O
O F
S L O
P E
ROOF SLOPE
R O
O F
S L O
P E
P E
R
R O
O F
S L O
P E
ROOF SLOPE
W/ PLATFORM
STEEL LADDER
DS
DS
DSGEJ
A
B
D
E
F
G
1 2 3 4 5 6 6.4 7 8 9 10
1"
14’-5"
1’-0"
11’-6"
15’-5"
5’-1"
15800
51’-10"
24800
81’-4"
22’-8"
29’-6"
17350
56’-11"
58050
190’-5"
1’
1’
1’
11’-6"
4’-11"
1’
ROOF EXHAUST PAN PANTHOUSE
VTR
1B
1A
N
A108
1A
1A
1B
1B
1C 1 43
1 43
NOTES:
APPLY PROTECTIVE COATING PER SPECIFICATION.
FASTENERS AS REQUIRED. PREPARE EXPOSED METAL PANELS AS REQUIRED AND
A WEATHERPROOF ROOF MEMBRANE. REPLACE MISSING OR DAMAGED PANEL
5. REPAIR, CLEAN AND RE-SEAL EXISTING METAL ROOF PANELS TO PROVIDE
NEW ROOF COATING.
4. REPAIR, CLEAN AND RE-FINISH EXISTING CHIMNEY TO MATCH
APPLY NEW PROTECTIVE COATING TO MATCH ADJACENT ROOF FINISH.
TO ENSURE OPERATING CONDITION. PREPARE SURFACES AS REQUIRED AND
3. REPAIR EXISTING ROOF HATCH, SAFETY RAILINGS, LADDER AND EXTENSION BAR
WITH SPECIFICATION.
INTERFACES. SEALANT MATERIALS AND APPLICATIONS SHALL COMPLY
2. APPLY NEW SEALANTS TO ALL ROOF JOINTS, GUTTERS AND MATERIAL
PENETRATIONS IN ACCORDANCE WITH SPECIFICATION.
1. REPLACE EXISTING CURBING, TRIM AND ACCESSORIES AT ALL ROOF
LEGEND
STANDING SEAM METAL ROOFING
GUTTER EXPENSION JOINT
DOWNSPOUT
GEJ
DS
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
NEW ROOF PLAN
NEW ROOF PLAN
1A
1A
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
D - 23 - 33
12 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SCALE : 1 / 100A
A 201
SCALE : 1 / 100
CURVED STANDING SEAM
PANEL (TYP)
FACADE
CLADDING
W/INSUL ON VR (TYP)DOWNSPOUT
PROTECTED METAL
FASCIA WALL PANEL
W/INSUL ON VB (TYP)
1ST FL
2ND FL
3RD FL
GREEN TINTED
INSULATED
GLASS (TYP)
FACADE CLADDING
PANEL (TYP)
W/INSUL ON VR (TYP)
SEAM METAL ROOFING
W/INSUL ON VB (TYP)
FASCIA WALL PANEL
PROTECTED METAL
(BEYOND)
FOR ROOF
DASHED LINE
3RD FL
2ND FL
1ST FL
PANNEL
FACADE CLADDING
(BEYOND)-TYP
FOR WALL
DASHED LINE
DOWNSPOUT
EAST ELEVATION
SOUTH ELEVATION
11109876432 51 6.4 6.5
F GD EA B C
W1 W2
A201
8 8
W1
1C
EXST FACE BRICK
EXST CURVED STANDING
FLOOR DECK (P-5/P-6)
PAINT STEEL TUBE POST, STEEL BEAM PLATE
EXST PROTECTED MET
PROTECTED METAL
FASCIA WALL PANEL
W/INSUL ON VB (TYP)
NOTES:
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
EAST ELEVATION
SOUTH ELEVATION /
9 103
773 10
773 10
9 103
9 103
SST
EXST
METAL ROOFING SYSTEM
MATCH WITH EXST
METAL SURFACE
RECOAT
1212 12 12 12
COATING AND PAINTS PER SPECIFICATION.
RECOAT EXPOSED METAL FINISHES AS REQUIRED AND APPLY PROTECTIVE
MISSING OR DAMAGED PARTS AND SURFACE ON THE DRAWING AS REQUIRED.
TUBE AND STEEL PIPE TO PROVIDE A WEATHERPROOF SURFACE. RE-PAINT
5. CLEAN, RECOAT AND RE-PAINT EXISTING WALL, COLUMN, BEAM, BRACE, STEEL
CONCRETE EXTERIOR BUILDING SURFACE PAINT TO COMPLY WITH SPECIFICATION.
4. APPLY NEW HIGH-BUILD ACRYLIC PAINT FINISH ALL EXPOSED
W/SST GUTTER, DOWNSPOUT-REFER TO FLOOR PLAN FOR DETAILED WORK.
3. REPLACE EXISTING METAL GUTTER, DOWNSPOUT W/CONC SPLASH BLOCKS
OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE HEAT.
BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE WHITE
2. WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL
APPLY FINISH PER SPECIFICATION. (TYPICAL AT EXTERIOR WINDOWS).
1. INSTALL NEW METAL FLASHING AT EXTERIOR WINDOW.
PLATE AND MATERIAL WITH FIELD TOUCH UP AS REQUIRED.
9. PROVIDE ANTI-CORROSIVE FOR METAL PROTECTIVE COATING ON ALL STEEL
APPLY PROTECTIVE COATING PER SPECIFICATION.
WALL PANELS FINISH. PREPARE EXPOSED METAL PANELS AS REQUIRED AND
AS REQUIRED AND APPLY NEW PROTECTIVE COATING TO MATCH ADJACENT
OR DAMAGED PANEL FASTENERS AS REQUIRED. PREPARE SURFACES
FASCIA WALL PANELS TO PROVIDE DAMP PROOFING. REPLACE MISSING
8. REPAIR, CLEAN, RE-SEAL AND RECOAT EXISTING PROTECTED METAL
NEW WALL PANELS COATING.
7. REPAIR, CLEAN AND RE-FINISH EXISTING CHIMNEY TO MATCH
CANOPY AS REQUIRED AND RESTORE BRICK FACE WALL.
6. PARTIALLY REMOVE BRICK FACE FINISH FOR AL SHEET REPLACEMENT OF
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
D - 23 - 33
13 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SCALE : 1 / 100A
A
SCALE : 1 / 100
W/INSUL ON VR (TYP)
SCUTTLE
PROTECTED METAL
FASCIA WALL PANEL
W/INSUL ON VB (TYP)
JOINT (TYP)
WALL CONTROL
METAL FASCIA
FL
1ST
FL
2ND
3RD FL
FINISH SYSTEM
METAL CANOPY (TYP)
CURVED STANDING SEAM
BLDG (BEYOND)
DASHED LINE FOR
FINISH SYSTEM
PANEL
FACADE
CLADDING
W/INSUL ON VR
CURVED STANDING SEAM
METAL ROOFING
3RD FL
2ND FL
1ST FL
WEST ELEVATION
NORTH ELEVATION
11 10 9 8 7 6 4 3 25 16.46.5
FG DE ABC
W2
A202
5 13
EIFS BACKGROUND COLOR)-TYP
PAINT CONC (COLOR: MATCH TO
EXST INSUL &
12EXST INSUL &
EXST BRICK FACE
FLOOR DECK (P-5/P-6)
PAINT STEEL TUBE POST, STEEL BEAM PLATE
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
AS SHOWN
WEST ELEVATION
NORTH ELEVATION /
1. REMOVE AND REINSTALL THE EXISTING EXTERIOR LIGHTING FIXTURES WITH
ALL NECESSARY ACCESSORIES ACCORDING TO WORK SCOPE.
2. REMOVE AND REINSTALL THE EXISTING SAFETY SWITCHES WITH ALL NECESSARY
ACCESSORIES ACCORDING TO WORK SCOPE.
3. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPLACE OR REPAIR ALL DAMAGES
TO EXISTING EQUIPMENT, PIPE, AND DUCT ACCORDING TO WORK SCOPE.
4. THE CONTRACTOR SHALL BE RESPONSIBLE TO REMOVE AND REINSTALL
THE OBSTRUCTED ITEMS SUCH EQUIPMENT, PIPE, AND DUCT TO MAKE WAY FOR
THE INSTALLATION AND REPLACEMENT OF WORK.
NOTES:
773 10
9 103
773 10
STEEL LADDER
EXST
ROOF
EXST
CHIMNEY
12 12 12 12
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
14 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
1ST FL
2ND FL
3RD FL
3RD FL
2ND FL
1ST FL
11109876432 51 6.4 6.5
F GD EA B C
A SCALE : 1 / 100
EXTERIOR WALL PLAN - 11
1A EAST
SOUTH1B
A203
1’
1’
1’
17867
58’-7"
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
EXTERIOR WALL PLAN - 1
SCOPE OF WORK SCOPE OF WORK
PROTECTED METAL FASCIA WALL
FACADE CLADDING PANNEL WALL
EQUIPMENT SCREEN WALL
1212 11 2 3 5
SCOPE OF WORK FOR WALL, ROOF AND ACCESSORIES (REFER TO FLOOR PLAN FOR OTHER SOWS)
TYPE
TYPE
STEEL TUBE AND STEEL PIPE
CONC WALL, COLUMN, BEAM, BRACE,
DOWNSPOUT AND FLASHING
PROTECTED METAL GUTTER, CONDUCT HEAD,
ROOF, CANOPY
9 103
773 10
FACE TO ROOF
PROTECTED METAL FLASHING
BRIDGE AREA 1212
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
15 33
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
3RD FL
2ND FL
1ST FL
FG DE ABC
FL
1ST
FL
2ND
3RD FL
11 10 9 8 7 6 4 3 25 16.46.5
A SCALE : 1 / 100
EXTERIOR WALL PLAN - 21
1A WEST
NORTH1B
A204
PAK, SIN YOL
KIM, CHI SOP
CAMP CARROLL
ARCHITECTURAL
17 JUL 23
EXTERIOR WALL PLAN - 2
SCOPE OF WORK SCOPE OF WORK
PROTECTED METAL FASCIA WALL
FACADE CLADDING PANNEL WALL
EQUIPMENT SCREEN WALL
1212 11 2 3 5
SCOPE OF WORK FOR WALL, ROOF AND ACCESSORIES (REFER TO FLOOR PLAN FOR OTHER SOWS)
TYPE
TYPE
STEEL TUBE AND STEEL PIPE
CONC WALL, COLUMN, BEAM, BRACE,
DOWNSPOUT AND FLASHING
PROTECTED METAL GUTTER, CONDUCT HEAD,
ROOF, CANOPY
9 103
773 10
FACE TO ROOF
PROTECTED METAL FLASHING
BRIDGE AREA 1212
HR-00513-9J
REPAIR ROOF AND EXTERIOR WALL AT B139
16 33
2620 (MIN)2620 (MIN)
S P
A N
D R
E L
G
L A S S
(T Y P
T
IN
T E
D
G L A S S
(T Y P
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DI…