Drawing.pdf

PDF 13 MB Posted

Attached to
Repair Roof and Exterior Wall at B139, CC, South Korea
Solicitation number
W90VN924R0033
Issued by

About this file

This document provides details on a federal contract opportunity to repair the roof and exterior wall of Building 139 located at Camp Carroll in South Korea. The solicitation number for this opportunity is W90VN924R0033 and is being issued by the Department of the Army Materiel Command Army Contracting Command. Interested parties should review the attached Drawing.pdf file and solicitation for additional scope of work requirements. The contract will require repair of both the roof and exterior wall at the specified building location. No further information is provided on response dates, pricing terms, or other contractual requirements.

View the file

Other files

File Type Posted
W90VN924R0033.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

R-11SHEET OF

DESIGNED BY

CHECKED BY

SUBMITTED BY

APPROVED BY

PROJECT NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

O & M

HOUSING DIV.

REVIEWED BY

UNITED STATES ARMY GARRISON DAEGU

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

DIRECTORATE OF PUBLIC WORK

HGFEDCBA

D - 23 - 33

CHON, HYON TAE

DESIGN REVIEW SIGNATURE

ORGANIZATION

USING AGENCY

36TH SIGNAL

MASTER PLN.

ENVIRONMENTAL

NAME SIGNATURE

O&M DIV.

FIRE DEPT.

SAFETY OFFICE

DPTMS(AT/FP)

188TH MP COM.

IND. HYGENIST

UNIT #15746, APO AP 96218-5746

DRAWING NO.

CHIEF,

DESIGN & TECH. REVIEW Br.

AS SHOWN

1 1 OF 1R - 1

T I T L E S H E E T

TITLE SHEET

USING AGENCY

DATE:17 JUL 23

HR-00513-9J

CAMP CARROLL

CIVIL

PROJECT NO. HR-00513-9J, CAMP CARROLL

ARCHITECTURAL

A001

A002

REPAIR ROOF AND EXTERIOR WALL AT B139

REPAIR ROOF AND EXTERIOR WALL AT B139

33 32 OF 33

25 24 OF 33

24 23 OF 33

23 22 OF 33

11 10 OF 33

10 9 OF 33

9 8 OF 33

34 33 OF 33

A003

A004

A101

A102

A103

A104

A105

A106

A107

A108

A201

A202

A203

A204

A301

A302

A303

A304

A305

A306

A307

A308

A309

A310

A311

A312

A313

A314

A401

A402

A403

NEW 1ST FLOOR PLAN

INTERIOR FINISH SCHEDULE, EXTERIOR FINISH SCHEDULE, GENERAL NOTES

WINDOW DETAILS, SEMI-EXPOSED GRID ACOUSTICAL, TILE CEILING DETAILS

WINDOW SCHEDULE, WINDOW TYPES, TYP SILL PAN FLASHING DETAIL

ROOF DETAILS - 5

ROOF DETAILS - 4

ROOF DETAILS - 3

ROOF DETAILS - 2

ROOF DETAILS - 1

CANOPY SECTION & DETAILS

CANOPY DETAILS

EXTERIOR WALL SECTIONS - 7

EXTERIOR WALL SECTIONS - 6

EXTERIOR WALL SECTIONS - 5

EXTERIOR WALL SECTIONS - 4

EXTERIOR WALL SECTIONS - 3

EXTERIOR WALL SECTIONS - 2

EXTERIOR WALL SECTIONS - 1

EXTERIOR WALL PLAN - 2

EXTERIOR WALL PLAN - 1

NORTH ELEVATION / WEST ELEVATION

SOUTH ELEVATION / EAST ELEVATION

ROOF EXIST / REMOVAL FLOOR PLAN

3RD EXIST / REMOVAL FLOOR PLAN

2ND EXIST / REMOVAL FLOOR PLAN

1ST EXIST / REMOVAL FLOOR PLAN

OVEROLL SITE PLAN, EQUIPMENT SCREEN ELEVATIONS

GENERAL NOTES, SCOPE OF WORK, SCOPE OF WORK FOR TYPE

ABBREVIATIONS, MATERIAL INDICATIONS AND SYMBOLS

GENERAL NOTES, SPECIFIC NOTES, MATERIAL NOTES

NEW ROOF PLAN

NEW 3RD FLOOR PLAN

NEW 2ND FLOOR PLAN

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

1.

2.

3.

6.

OF CONSTRUCTION SHALL BE USED.

NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS

DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE

EXISTING UTILITIES AS A RESULT OF HIS/HER WORK.

OF CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL PAY FOR ALL DAMAGES TO

TO UTILITIES. NOTIFY THE OWNER’S REPRESENTATIVE OF ANY UNDERGROUND UTILITIES IN THE WAY

EXTREME CAUTION AND MUST EXERCISE PROPER CARE DURING EXCAVATION TO PREVENT DAMAGE

ACCURACY OR THE EXISTENCE OF OTHER OBSTACLES WHICH MAY BE ENCOUNTERED WORK WITH

PLANS ARE FROM THE LATEST AVAILABLE RECORDS BUT ARE NOT GUARANTEED AS TO THE

THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITIES AND STRUCTURES AS SHOWN ON THESE

4.

LOCATIONS AND DEPTHS PRIOR TO EXCAVATION FOR THE NEW LINES.

CONTRACTOR SHALL EXPOSE THE EXISTING LINES AT THE PROPOSED CONNECTIONS TO VERIFY THEIR

WHEREVER CONNECTIONS OF NEW UTILITIES TO EXISTING UTILITIES ARE SHOWN ON THE PLANS, THE

THE PROJECT AREA PRIOR TO EXCAVATING. THE CONTRACTOR SHALL COORDINATE ALL WORK.

THE CONTRACTOR SHALL NOTIFY ALL AGENCIES TO VERIFY THE ACTUAL LOCATION OF ALL UTILITIES IN

5.

ADDITIONAL COSTS TO THE OWNER.

SCHEDULED TO REMAIN DURING THE CONSTRUCTION PERIOD WHICH SHALL BE REPAIRED AT NO

THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES INCURRED TO EXISTING WORK

7.

PATCHING SHALL MATCH THE FINISH OF THE ADJACENT SURFACES.

THE CONTRACTOR SHALL PATCH ALL SURFACES EXPOSED FROM CUTTING, AND/OR REMOVAL WORK.

8.

ACCESSIBILITY GUIDELINES (ADAAG).

ALL STANDARDS, REQUIREMENTS AND GUIDELINES OF THE AMERICANS WITH DISABILITIES ACT

ALL GOVERNING AGENCIES. THIS WORK SHALL BE DESIGNED AND CONSTRUCTED TO CONFORM WITH

ALL WORK SHALL CONFORM TO ALL APPLICABLE LAWS, CODES, REGULATIONS, AND ORDINANCES OF

9. ALL DIMENSIONS SHOWN ON FLOOR PLAN ARE TO FACE OF FINISH, UNLESS OTHERWISE.

10.

PROVIDE DUST CONTROL MEASURES AS REQUIRED.

CLEAN AND FREE FROM ACCUMULATION OF WASTE MATERIALS AND RUBBISH. CONTRACTOR SHALL

AREA, THE OWNER’S PREMISES, INCLUDING STREETS AND OTHER AREAS USED BY THE CONTRACTOR

CONTRACTOR SHALL, AT ALL TIMES, DURING THE COURSE OF THE WORK, KEEP THE CONSTRUCTION

11.

OF OPERATIONS, INTERRUPTION OF MECHANICAL AND ELECTRICAL UTILITIES.

DELIVERY ACCESS TO AND FROM WORK, SPECIAL NOISY OPERATIONS, TIMING OF WORK, SEQUENCE

COORDINATE ALL OPERATIONS WITH THE OWNER’S REPRESENTATIVE FOR MATERIALS STORAGE,

12.

DEBRIS, RUBBISH, AND CONSTRUCTION MATERIAL AT TIME OF FINAL ACCEPTANCE.

REMOVE BARRICADE AFTER COMPLETION OF THE PROJECT AND CLEAN THE PROJECT AREA OF ALL

PREVENT PEOPLE FROM ENTERING THE PROJECT AREA AND TO PROTECT THE ENCLOSED PROPERTY.

CONTRACTOR SHALL PROVIDE BARRICADES, AS REQUIRED, AND ACCEPTABLE TO THE OWNER TO

13.

REPRESENTATIVE.

TRADE SHALL BE USED TO RESOLVE SUCH DISCREPANCIES AND MUST BE APPROVED BY THE OWNER’S

SUBMIT SHOP DRAWINGS ON HOW THEY WILL RESOLVE SUCH DISCREPANCIES. GENERAL PRACTICE OF

SHALL BE BORNE BY THE CONTRACTOR AND IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO

QUESTIONS RAISED DURING CONSTRUCTION PHASE THAT MAY RESULT IN EXTRA COST, SAID COST

ALL DISCREPANCIES FOUND ON DRAWINGS DURING CONSTRUCTION PHASE, ANY DISCREPANCIES OR

IT SHALL BE CONTRACTOR’S RESPONSIBILITY TO NOTIFY THE OWNER’S REPRESENTATIVE FOR ANY OR

14. CONTRACTORS SHALL VERIFY ALL QUANTITIES.

STATE PROPERTY IN ACCORDANCE WITH ALL LOCAL GOVERNING LAWS AND REGULATIONS.

BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF OUTSIDE THE LIMITS OF

ALL MATERIALS REQUIRED TO BE DISPOSED OF IN THIS PROJECT UNLESS REQUIRED TO BE SALVAGED, INTENDED TO LIMIT THE WORK REQUIRED IN ANY WAY.

TITLES, CAPTIONS, HEADINGS, ETC. ARE INTENDED FOR GENERAL REFERENCE AND ARE NOT

THE ABOVE NOTES APPLY TO THE FULL SET OF CONSTRUCTION DOCUMENTS.

1.

2.

3.

4.

GENERAL NOTES

OFFICER.

ANY DISCREPANCIES SHALL BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE CONTRACTING

PRIOR TO COMMENCING ANY CONSTRUCTION.

THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION AND DIMENSIONS

THE CONTRACTING OFFICER.

AREAS CAUSED BY THIS PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AS DIRECTED BY

THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING

TRAFFIC AND OPERATIONS.

NECESSARY PRECAUTIONS FOR THE PROTECTION AND SAFETY OF THE PUBLIC AND/OR MILITARY

BARRICADES, MARKERS, CONES AND OTHER PROTECTIVE FACILITIES AND SHALL TAKE ALL

THE CONTRACTOR SHALL PROVIDE, INSTALL, AND MAINTAIN ALL NECESSARY SIGNS, LIGHTS, FLARES, CONTRACTOR.

INCURRED FOR SPILL CONTAINMENT AND CLEAN-UP SHALL BE THE RESPONSIBILITY OF THE

OFFICER SHALL OVERSEE THE CLEAN-UP EFFORT AND RENDER THE SITE CLEAN. ALL COSTS

APPROPRIATE MEASURES TO CONTAIN AND ADEQUATELY CLEAN-UP THE SPILL. THE CONTRACTING

CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER AND UTILIZE

THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY SEWAGE SPILLS CAUSED DURING

WORK.

OF THIS WORK MUST BE DONE TO INSURE ROUGH-IN WORK IS ACCOMPLISHED PRIOR TO FINISHING

REPLACEMENT OF MECHANICAL, ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM COORDINATION

CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING TO MAKE WAY FOR THE INSTALLATION AND

INCONVENIENCE TO THE CUSTOMER’S MISSION OPERATION.

APPROVAL FROM THE GOVERNMENT AND EXECUTE WORK STAGE BY STAGE WITHOUT ANY

THE CONTRACTOR SHALL SUBMIT WORK SCHEDULE PRIOR TO COMMENCING THE WORK AND GET

CONTRACTOR.

THAT MAY OCCUR DURING THE COURSE OF HIS WORK SHALL BE RESTORED AT THE EXPENSE OF THE

THE CONTRACTOR SHALL TAKE MEASURES TO PROTECT EXISTING FACILITIES AND ANY DAMAGES

MATCHING EXISTING COLOR AND FINISH.

ANY STRUCTURAL STEEL MEMBERS EXPOSED TO INTERIOR SPACE SHALL BE RE-PAINTED WITH

CONTRACTING OFFICER AT THE LOCATION INDICATED BY CONTRACTING OFFICER.

SALVAGEABLE MATERIALS SHALL BE REMOVED FROM WORK SITE IN A MANNER AND TURNED OVER TO

1.

2.

3.

4.

CONDITIONS AND SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.

SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD

SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS.

15. FILL EXISTING DUCT AND PIPE HOLE W/ CONCRETE.

16.

RESPONSIBLE FOR REPAIR OR REPLACEMENT OF ACCESS DOOR AND WALL.

THE CONTRACTOR SHALL VERIFY THE NEW EQUIPMENT ACCESS CONDITIONS AT JOB SITE AND WILL BE

17.

18.

19.

AND SPECIFIC NOTES ON THE CONTRACT DRAWINGS.

THE CONTRACTOR SHALL FOLLOW THE CONSTRUCTION WORK AS INDICATED ON THE GENERAL NOTES

20.

CONTRACTOR SHALL SUBMIT ALL MATERIAL & COLOR SAMPLES TO DPW FOR APPROVAL.

COLOR AND PATTERN WHICH MANUFACTURERS STANDARD MUST APPROACH.

MATCH FOR MANUFACTURER COLOR IS NOT REQUIRED. THE SELECTIONS SERVE ONLY TO INDICATE

NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE MANUFACTURERS INDICATED. AN EXACT

COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR IDENTIFICATION PURPOSES ONLY, AND

CONTRACT DRAWING.

THE CONTRACTING OFFICER. A SHOP DRAWING SHALL NOT BE THE EXACT DUPLICATION OF THE

CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL TO

5.

INSTALLATION.

DETAILS AND DRAWING SHALL BE APPROVED BY THE C.O. OR HIS COR. BEFORE FABRICATION AND

INSTRUCTIONS. THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR AND WINDOW

ALL DOORS AND WINDOWS SHALL BE FABRICATED I.A.W. SPECIFICATIONS AND MANUFACTURER’S

CONTRACT.

ACCOMPLISH THE ARCHITECTURAL SCOPE OF WORK AT NO ADDITIONAL COST TO THE PROJECT

AGENCY, KOREA REGION OFFICE" FROM A PART OF THIS PROJECT. THE DETAILS WILL BE UTILIZED TO

PROJECTS, KOREA, NOVEMBER 30, 2015, DEPARTMENT OF THE ARMY INSTALLATION MANAGEMENT

THE ARCHITECTURAL STANDARD DRAWINGS SHOWN IN THE "STANDARD DETAIL DRAWINGS FOR O&MA 5.

6. REMOVE & CLEAN EXISTING FINISH MATERIAL & ADHESIVE BY GRINDING TO RECEIVE VCT & TILE.

7. REMOVE & CLEAN EXISTING PAINT BY SAND PAPER/ GRINDING FOR NEW PAINTING AND COATING.

8.

FREE.

SHEET (MSDS), WRITTEN IN ENGLISH, FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD

OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE A CERTIFICATE OR MATERIAL SAFETY DATA

LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON-VOLATILE SOLIDS) DURING THE EXECUTION

THE CONTRACTOR IS REQUIRED TO USE "LEAD FREE" COATINGS (LIQUID PAINTS OR COATINGS WITH

9.

AND USER.

THE CONTRACTOR SHALL COORDINATE ALL PHASES OF WORK WITH THE CONTRACTING OFFICER

REQUIREMENTS MANUAL EM 385-1-1 LATEST EDITION.

THE CONTRACTOR SHALL PERFORM ALL WORKS IN ACCORDANCE WITH USACE SAFETY AND HEALTH

AND THE ENVIRONMENTAL GOVERNING STANDARDS FOR KOREA, USFK REGULATION 201-1.

ALL DISPOSAL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE KOREAN ENVIRONMENTAL LAWS

CONTRACT, AND SHALL BE RESOLVED BEFORE PROCEEDING WITH THE WORK.

OMISSIONS OR CONFLICTS WHICH PREVENT HIM OR HER FROM FULFILLING THE TERMS OF THE

CONTRACTOR SHALL PROMPTLY NOTIFY THE OWNER’S REPRESENTATIVE OF ANY DISCREPANCIES, WITH THE REQUIRED WORK.

SHALL VERIFY ALL CONDITIONS AND DIMENSIONS RELATING TO THE PROJECT BEFORE COMMENCING

THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND

WITHOUT WRITTEN APPROVAL OF THE OWNER’S REPRESENTATIVE.

THAT THE PROPER REVISIONS MAY BE MADE. MODIFICATION OF DETAILS SHALL NOT BE MADE

CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE OWNER’S REPRESENTATIVE SO

BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS

ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE

6.

7.

8.

9.

10.

11.

12.

13.

SPECIFIC NOTES MATERIAL NOTES

THROUGH COR.

NEW SURVEY REPORT AND ASBESTOS REMOVAL DOCUMENTATION TO ENVIRONMENTAL OFFICE

THE KOREA ENVIRONMENTAL GOVERNING STANDARD (KEGS). THE CONTRACTOR SHALL PROVIDE THE

PRIOR TO ANY WORK TO ASSURE THAT APPROPRIATE ASBESTOS CONTROL IS IN ACCORDANCE WITH

THE WORK AREA WILL NEED TO BE RESURVEYED AND ASBESTOS MATERIALS SHOULD BE REMOVED

CONTRACTOR SHALL CASE WORK IN THE AFFECTED AREA AND NOTIFY THE CONTRACTING OFFICER.

WORK. HOWEVER, IF SUSPECTED ASBESTOS CONTAINING MATERIAL ARE DISCOVERED, THE

FREE. TESTS HAVE INDICATED THAT ASBESTOS IS NOT PRESENT IN THE AREA AFFECTED BY THIS

OR MSDS, WRITTEN IN ENGLISH, FROM THE MANUFACTURER VERIFYING THE PRODUCT IS ASBESTOS

WEIGHT) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE A CERTIFICATE

THE CONTRACTOR IS REQUIRED TO USE "ASBESTOS FREE" MATERIALS (LESS THAN 1 PERCENT BY

A001

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

MATERIAL NOTES

SPECIFIC NOTES

GENERAL NOTES

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

D - 23 - 33

1 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

A

AMPERE

AT

ANCHOR BOLT

DROP, DEW POINT,

FD FLOOR DRAIN

NATIONAL ELECTRICAL

TOP OF STEELT.O.S.

NEMA

CEMENT PLASTER

DOWNSPOUT

DRAIN MANHOLE

DOUBLE POLE SINGLE THROW

DIVISION

DRINKING WATER DISPENSER

DRAWING(S)

DWELLING

CARPET

M A T E R I A L I N D I C A T I O N S A N D S Y M B O L S

DESIGN PACKAGE

DRINKING FOUNTAIN

DETAIL(S)

DIAMETER

DIAGRAM

DIMENSION

DISTRIBUTION

DAYLIGHT, DEAD LOAD

DRAWING LIST, DRAIN LINE

DROP MANHOLE

DRAIN OR DOOR

DOWN

DRY BULB

CAST STEEL

DESIGN

DOOR STOOP

DOUBLE

DISCONNECT

CORRIDOR

CORNER

CURVE

CEMENT PLASTER CEILING

CONCRETE PIERCING

CONTRACTION JOINT

COATING, CUTTING

CUBIC FOOT

COLD WATER

CORRUGATED THRESHOLD

CAPILLARY WATER BARRIER

CHECK VALVE

CPL

DS

DMH

DPST

DIV

AWP ACOUSTICAL WALL PANEL

ATT ASPHALT TIRE TILE

DWD

CAT CATALOG

DWG(S)

DWEL

BB BULLETIN BOARD

CPT

& RADIALOGICAL

CBR CHEMICAL BIOLOGICAL

DIAG

DF

DB

DET(S)

DIM

DISTR

DL

DMA

DN

DP

DR

BREAKERBRKR

DSGN

DST

DBL

DISC

CENTER TO CENTERC TO C

COR

CORR

CPC

CRV

CP

CS

CTG

CUFT

CTRJ

CONDUIT

CW

C

CAPACITYCAP

CT

CWB

CV

AVERAGE

ASSEMBLYASSY

AVG

BELL & SPIGOT

BARRIER

BOTTOM CHORD

BOARD

BOLT CIRCLE

BARR

B & S

BD

BC

BELL END

BOILER FEED WATER

BOILER HORSE POWER

BOILER HOUSE

BFW

BE

BH

BHP

BLOCKING

BUILDING(S)

BLOW-OFF

BOTTOM

BLDG(S)

BLKG

BOT

BO

BKS BARRACKS

BRICK

BASE PLATE, BRICK PAVER

BRITISH THERMAL UNITS

BRITISH THERMAL UNITS

BOTH SIDES

BP

BRK

BTU

BTUH

BS

BULL NOSE BLOCK

PER HOUR

BN

ANGLE STOP VALVE

ACOUSTIC TILE CEILING

AMPERE TRIP

AUTOMATIC

AMERICAN WIRE GAGE

AMERICAN SOCIETY FOR

TESTING & MATERIAL

ATC

AT

ASV

AUTO

AWG

ASTM

GCWT GLAZED CERAMIC WALL TILE

LL LIVE LOAD

LB POUND

LINEAR FEETLF

PAV, PVMT PAVEMENT

WALL PANEL

SOUND ABSORPTIONSAWP

LVL LEVEL

RETURN AIR REGISTER

REPAIR

RUBBER TILE

RIVET

RAW WATER

RIDGE VENT

SI SURFACE INLET

WALK-OFF MATMAT

SOAP DISPENER

RS RUBBER SHEET

RP RUBBER PAD

LC LAVATORY COUNTERTOP

RF RUBBER FLOORING

PCC

POL

POC

PG

PEJ

PRESS GAGE

POINT OF CONNECTION

PETROLEUM, OIL & LUBRICANT

PORTLAND CEMENT CONCRETE

PREMOLDED EXPANSION JOINT

RG

REF

RECT

REPL

RELOC

REV

RM

RPM

RHWS

RHMS

RL

RO

REINF

RET

REFL

RFT

REFR

REQ’D

REFRIGERATOR

REFLECTED

RETAINING

REINFORCEMENT

RUBBER FABRIC TITLE

ROOF LINER

ROUGH OPENING

ROUND HEAD WOOD SCREW

ROUND HEAD METAL SCREW

RV

RW

RVT

RT

REVOLUTIONS/ MINUTE

REQUIRED

ROOM

RPR

REVIEW, REVISE

REPLACE

RELOCATED

RECTANGULAR

REFERENCE

RR

RETURN AIR GRILLE

PLATE, PLASTIC LAMINATEPL

FLUOR

FDN

FED

FHY

FL

FDR

FRAME

FIXTURE

FIXED

FOOT, FLOOR TILE

FR

FS

FXTR

FXD

FPM

FHMS

FT

FINISH

FREEZER

FRAMING

FY

FNSH

FF

FRZA

FE

FOS

FOR

FEC

FRAMG

FHWS

FIRE DOOR

FEDERAL, FAR EAST DISTRICT

FOUNDATION

FLUORESCENT

FUEL OIL SUPPLY

FUEL OIL RETURN

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FINISH FLOOR, FACTORY FINISH

FAR SIDE, FULL SIZE

FLOOR OR FLOOR LINE

FLASHING, FLUSH

FIRE HYDRANT

FISCAL YEAR

FLAT HEAD WOOD SCREW

FEET PER MINUTE

FLAT HEAD METAL SCREW

GAGE

GALLON

GROUND

G

GA

GAL

GALV

GL

GND

GEN

GFM(M)

GSS

GTV

GSP GALVANIZED STEEL PIPE

GALVANIZED STEEL SHEET

GATE VALVE

GRADE LINE

PROPERTY (MATERIAL)

GOVERNMENT FURNISHED

GALVANIZE

GENERATOR

GIRDER, GLASS

SIMILAR

SLOPE

SIM

SLP

SP

SDL

SHLDR

SH

SECT

SADDLE

STATIC PRESSURE

SECTION

SHOWER HEAD OR SHEET

SHOULDER

SOLV

SPEC(S)

SPDT

SPM

SPH

SOLENOID VALVE

DOUBLE-THROW

SINGLE-POLE

STROKES PER MINUTE

SPACE HEATER

SPECIFICATION(S)

STAIR NOSINGSN

INLETINL

INSULATION

ISOLATION JOINT

INVERT

INTERIOR

INSECT SCREEN

INCANDESCENT

IDENTIFICATION

INSUL

IJ

INVT

INTR

IS

INCAND

IDENT

INSTALLATIONINSTL

STORAGESTOR

MANUFACTURERS ASSOCIATION

MATERIAL

NUMBER

NOMENCLATURE

NOT IN CONTRACT

NOT TO SCALE

OUT TO OUT

OVERALL

NON FROST SUSCEPTIBLE

SPLITTER DAMPER

SUPPLY AIR GRILLE

SEWER MANHOLE

SEWER LINE

SCHEDULE

SINGLE KEYED DIFFERENT

SD

SG

SMH

SL

SKD

SCHED

ON CENTER

OCTAGON

OVERHEAD

OVERLOAD

ORIGINAL

OPTIONAL

OUTLET

OUTSIDE DIAMETER

OPENING

PILE CAP

POLE, PLATE, PAPER

POST INDICATOR VALVE

PUSH BUTTON

POWER DRIVEN

PEDESTAL

SCREEN DOOR

SCALE

SELECTOR

SCD

SC

SEL

SCREW

SIDINGSDG

SCR

PHASE

PLASTER

PLYWOOD

PANEL

PLUSE POSITION MODULATION

PAINT

PERMANENT

NO OR #

NOMEN

NIC

NTS

O TO O

OA

NFSM

INCH

INCLUDE

IN

INCL

JOINT

JOIST

J

JT

KILOWATT

KILOWATT HOUR

KOREAN STANDARD

KILOVOLT AMPERE

KWH

KW

KS

KVA

OC

OCT

OL

O/H

ORIG

OPTL

OD

OUT

OPNG

P

PC

PIV

PB

PDVN

PED

LONG

LAVATORY

LIGHTING ARRESTER

L

LA

LAV

LINTEL

LONGITUDINAL

LATTICE

LNTL

LTC

LONG

LG LENGTH

LAYOUT

LOUVERED DOOR

LEAVING

LVD

LTY

LVG

LIGHTING

LATCHING THRESHOLD

LOWER PRESSURE SODIUM

LT

LTG

LPS PLAS

PH

PNL

PLYWD

PPM

PNT

MAINTENANCE & REPAIR

MACHINE

M & R

MACH

PERM

GALLON PER MINUTE

GENERAL

GPM

GENL

WL WATER LINE

PORTER

VINYLE COVERED WALL PADDING VWP

VST VINYL SHEET TILE

VSF VINYL SHEET FLOORING

URINAL SCREENUS

TOILET TISSUE DISPENSERTTD

TUFV TOUCHLESS URINAL

FLUSH VALVE

VRB VENT RUBBER BASE

WOOD FLOORINGWF

WATER

WALL FOOTING

WM

W/O

WP

WT

WTR

WWF

WF

WIRE MESH

WITHOUT

WORKING POINT

WEIGHT

WELDED WIRE FABRIC

WLB WALL BOARD

WATER LINE OR WALL

W

WA

W/

WCR

WDO

WH

WL

WD

WB

WC

WATT

WAINSCOT

WOOD BASE, WET BULB

WATER CLOSET, WALL COVERING

WATER COOLER

WITH

WIDTH OR WOOD

WINDOW

WALL HYDRANT

WIND LOAD

VINYL COVE BASE

VAR

VCB

VTR VENT THROUGH ROOF

VARIOUS

VEST

VOL

VESTIBULE

VOLUME

VELOCITY

VINYL COMPOSITION TILE

VERTICAL

VENTILATOR

VITRIFIED CLAY TILE,

VEL

VERT

VENT

VCT

VALVE BOX, VAPOR BARRIER

VACUUM

VOLT

VB

VAC

V

UNIFORM

UNIT HEATER

"U" SHAPED STIRRUP

URINALUR

U

UH

UNIF

UNDERWRITERS LABORATORIES

AND

THREE WAY

SAME AS ABOVE, DITTO"

3 WAY

UL

UGND UNDER GROUND

TELEVISION TURNING VANES

TOTAL

TYPICAL

TILE WAINSCOT

TOT

TV

TYP

TW

CONTAMINATION CONTROL AREA

CONTINUOUS

COLUMN FOOTING

WATER (RETURN)

CMU CONTROL JOINT

CAST IRON PIPE

CAST IRON

CENTER LINE

CONTROL JOINT

CAULKING

COLOR, CLEAR

CEILING, COOLING

CHILLED DRINKING

CUBIC FEET PER MINUTE

CLEAR WIRE GLASS

CERAMIC MOSAIC TILE

CORRUGATED METAL PIPE

CONCRETE

COLUMN

CONNECTION

CONSTANT

CONCRETE MASONRY UNIT

CEILING DIFFUSER

CHANNEL

CEILING HEIGHT

CATCH BASIN

CIRCUIT

ACST ACOUSTICAL TILE

BAFFLE PANEL

AHBP ACOUSTICAL HANGING

CCA

CONT

CF

CIP

CJ

CI

CLJ

CLR

CLKG

CLG

CDW(R)

CLWR

CFM

CMP

CMT

COL

CONC

CONST

CONN

CMU

CD

CHAN

CH

CB

CKT

ASPHALTIC CONCRETEAC

ACCESS PANEL

ABOVE TILE FINISHED FLOOR

AP

AFF

ACCESS ACCESSORY

ASBESTOS CEMENT BOARD

ACCESS

AREA DRAIN

AIRCRAFT

ADJACENT

ADHESIVE

ALUMINUM

ANCHOR

AIR HOUSE POWER

AIR CONDITIONING

APPENDIX

ALTERNATE

APPROXIMATE

ARCHITECTURE

A

ASPHALT

AS SOON AS POSSIBLE

AIR EXTRACTOR

A

ASPH

ASAP

AE

ADJ

AHP

AL

APPROX

APPX

ALT

ARCH

AHR

ACFT

ACS

ADH

AD

A/C

ACB

AB

V TERBBA

FINISH SYSTEM

EIFS EXTERIOR INSULATION & HDR HARDENER

PT PAVER TILE

MOPR

PTDWR PAPER TOWEL DISPENSER

W/ RECEPTACLE

MOP RACK

METAL ROOF LINERMRL

MIRROR GLASSMG

H/C HANDICAP

PWR

PSI

PRV

PRESS

PSIG

PROV

PROT

PSF

POWER

PRESSURE

PRESSURE REDUCING VALVE

POUNDS/ SQUARE INCH

POUNDS/ SQUARE INCH GAGE

PROVIDE

PROTECTION

POUNDS/ SQUARE FOOT

QTY

QT

QTF

R

RAD

RBR

RC

RCP

RCPT

RE-BAR

RD ROAD

REINFORCED CONCRETE PIPE

RECEPTACLE

REINFORCING BAR

RUBBER

REINFORCED CONCRETE

RADIUS

RAIL, RIGHT

QUARRY TILE

QUARRY TILE FLOOR

QUANTITY

EACH

EXISTING

EXT

EDR

EA

EXST

ENCL

EST

EP

EXH

ESP

ENT

EXP JT

ENGRG

EL, ELEV

EXPANSION JOINT

ENTERING, ENTRANCE

ESTIMATE

EXHAUST

EQUIVALENT DIRECT RADIATION

EXPLOSION PROOF

ENGINEERING

ELEVATION

ENCLOSURE

EXTERIOR

EXTERNAL STATIC PRESSURE

ELEC

ETC

EW

EWC

EMER

FABL

FACTOR

FC

FAC

FCO

F

EACH WAY

FIRE ALARM BELL

FUSE CUTOUT

EMERGENCY

ELECTRICAL

ELECTRIC WATER COOLER

ETCETERA

FLOOR CLEAN OUT

DEGREE FAHRENHEIT

EVAP EVAPORATING

GWT

GWB GYPSUM WALL BOARD

GLAZED WALL TILE

HIGH PRESSURE SODIUM

HIGH POWER FACTOR

INDIRECT DRAIN

INSIDE DIAMETER

HPS

HPF

ID

IN ACCORDANCE WITHIAW

NATIONAL ELECTRICAL CODE

PROJECT

PROOF

PREFABRICATED

PARTITION

NEC

PROJ

PRF

PREFAB

PTN

MILES PER HOURMPH

MAXIMUM

MIDDLE, MODULE

MECHANICAL

MAGNETIC CONTACTOR

MAX

MDL

MECH

MC

MATL MATERIAL

METAL DOOR

METAL

MINIMUM

MEZZANINE

METD

MET

MIN

MEZZ

MACHINE SCREW

METAL THRESHOLD

BRITISH THERMAL UNITS

MOUNTING

MSCR

MT

MBH

MTG

MISC MISCELLANEOUS

METAL SCREW

MACHINE BOLT

MIRROR

MASONRY OPENING

MS

MB

MR

MO

MILLIMETER

MANUFACTURE

MM

MFR

PER HOUR (THOUSANDS)

HIGH, HEAD, HORIZONTAL

HOSE BIBB

HARD DRAWN BARE COPPER

HARDWARE

HEIGHT

HOLLOW METAL

HERTZ

HORSE POWER

HEATER

HARD BOARD

HARDWOOD

HOT WATER

HOUR

HEATING AND VENTILATION

HORIZONTAL

HEXAGON

HB

H

HDBC

HDW

HM

HGT

HP

HZ

HTR

HDBD

HDWD

HW

HR

HORIZ, HOR

H/V

HEX

N SOII A

TELECOMMUNICATIONTELECOMM

SPST SINGLE-POLE

STEEL SHEET OR

STAINLESS STEEL

SERVICE SINK

STATION

STEEL

STRUCTURAL

STANDARD

STAIRWAY

SWITCH

SAFETY VALVE

SUSPENDED

SELF-TAPPING

SS

SST

STA

STL

STRL

STD

STWY

SW

SV

SUSP

ST

SYSTEM

SUPPLY AIR REGISTER

STIFFENER

STORAGE

TITLE BLOCK

TELEPHONE

TERRA COTTA

THICKNESS

TEMPORARY OR TEMPERATURE

SYS

SR

STIFF

STOR

T/B

TC

TEL

THK

TEMP

THERMOMETER

TECHNICAL

TH

TECH

THRU THROUGH

DOOR NUMBER

WINDOW & LOUVER NUMBER

ROOM NUMBER

SINGLE DOOR

DOUBLE DOOR

DOUBLE ACTING DOOR-SINGLE

DOOR

DOUBLE ACTING DOOR-DOUBLE

DOOR

DOUBLE ACTING DOOR-IN

& DOOR-OUT

FOLDING DOOR OR FOLDING

PARTITION

SLIDING DOOR

POCKET DOOR

OVERHEAD COILING DOOR

WINDOW, DOUBLE HUNG

WINDOW, DOUBLE-OPENING OUT

WINDOW, SINGLE-OPENING OUT

WINDOW, HORIZONTAL-SLIDING

LOUVERED OPENING

D1

W1 L1

( A R C H I T E C T U R A L )

CL

A002

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

SYMBOLS

MATERIAL INDICATIONS AND

ABBREVIATIONS

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

2 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

REPAIR AND MAINTENANCE WORK

SCOPE OF WORK

ARCHITECTURAL

CAMP CARROLL

A003

PAINT INTERIOR WALL.

REPLACE EXISTING ACOUSTICAL CEILING TILE UNIT.

SCOPE OF WORK

PROTECTED METAL FASCIA WALL

FACADE CLADDING PANNEL WALL

TYPE

STEEL TUBE AND STEEL PIPE

CONC WALL, COLUMN, BEAM, BRACE,

1212EQUIPMENT SCREEN WALL

11 2 3 5 13

DOWNSPOUT AND FLASHING

PROTECTED METAL GUTTER, CONDUCT HEAD,

4 6ROOF, CANOPY

CEILING

WINDOW

E X T E

R

IO

R

IN

T E

R

IO

R 14

REMARKS

WALL

ROOM NO: 303 / 304 / 305 / 308 / 309

SCOPE OF WORK FOR TYPE

FINISH SCHEDULE

INTERIOR

SEE

A203 / 204

SEE SHEET

FINISH SCHEDULE

INTERIOR

SEE

SCHEDULE

SEE WINDOW

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

SCOPE OF WORK FOR TYPE

SCOPE OF WORK

GENERAL NOTES

INCLUDING NECESSARY ACCESSORIES.

REPLACE EXISTING PARAPET CAP FLASHING WITH ALUMINUM SHEET CAP FLASHING

REPLACE EXISTING STRUCTURAL STANDING SEAM METAL ROOFING WITH ROOF INSULATION.

REPLACE EXISTING WINDOW WITH NEW INCLUDING BLIND AND NECESSARY ACCESSORIES.

RECOAT EXISTING EXTERIOR PROTECTED METAL FASCIA WALL.

RECOAT EXTERIOR SURFACE.

PROVIDE CONCRETE SPLASH BLOCK.

REPLACE EXISTING VINYL COVE BASE WITH NEW.

ROOM NO: 303 / 304 / 305 / 308 / 309

16 REPLACE EXISTING PROTECTED METAL FLASHING WITH NEW INCLUDING NECESSARY ACCESSORIES.

INCLUDING NECESSARY ACCESSORIES.

REPLACE EXISTING FACADE CLADDING PANEL AND SUPPORT FRAME WITH NEW

FASCIA WALL WITH NEW INCLUDING AIR AND WATER RESISTIVE BARRIER AND NECESSARY ACCESSORIES.

REPLACE EXISTING INSULATION UNDER FACADE CLADDING PANEL AND PROTECTED METAL

AND NECESSARY ACCESSORIES.

REPLACE EXISTING RAIN GUTTER WITH NEW INCLUDING FLASHING

CANOPY - RESTORE PARTIALLY REMOVED BRICK FACE.

REPLACE EXISTING ALUMINUM SHEET PANEL AND FLASHING WITH NEW AT THE ENTRANCE

INCLUDING FLASHING AND NECESSARY ACCESSORIES.

REPLACE EXISTING RAIN GUTTER WITH STAINLESS STEEL RAIN GUTTER

BRIDGE AREA 1212

CONDUCT HEAD AND DOWNSPOUT INCLUDING NECESSARY ACCESSORIES.

REPLACE AND PROVIDE EXISTING CONDUCT HEAD AND DOWNSPOUT WITH STAINLESS STEEL

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

3 33

27800

57600

17550

7350 4900

3370034600

A

B

1 52 3 4 6 7 8 9 10 11

F

G

D

E

C

TO CENTER OF WALL

R=33528 TO

CENTER OF WALL

R=30000

TO EDGE OF CANOPY

DN

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

A SCALE : 1 / 50

R=33150

N

EQUIPMENT SCREEN

A004

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

TOP OF

STEEL BEAM

TOP OF CONC

TOP OF INT. GRAVELTOP OF CONC

TOP OF INT. GRAVEL

STEEL BEAM

TOP OF

2A

2B

A

OVERALL SITE PLAN

SCALE : 1 / 200004

A B

EQUIPMENT SCREEN ELEVATIONS

EQUIPMENT SCREEN ELEVATIONS

OVEROLL SITE PLAN

2A 2B

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

4 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

S L

O P

E

104106

STAIR-4

STAIR-2

STORAGE-2

UP

JAN

DN

INDOOR

OUTDOOR

ROOM

VEST-3

W TOILET

STORAGE-1

COMM ROOM

M TOILET

CORRIDOR-1

STAIR-3

MECH ROOM

PLATFORM

TOILET

DN

AV EQUIPMENT RM

ROOM

W DRESSINGM DRESSING

ROOM-2

CONCESSIONHALL

ROOM-1

MULTI-PURPOSE

VEST-1

ELEV

ROOM

MACH

PLATFORM

ELEC ROOM

STORAGE

COMMUNITY KITCHEN

AHU ROOM

VEST-2

PARTITION

FOLDING

STORAGE

116 120

VEST-4

VEST-5

134135

ELEC CLOSET

UP

ELEV

STAIR-1

UP

UP

UP

DN

KITCHEN

CORRIDOR-2

DN

DN

MULTI-PURPOSE

FUTURE

W1

20’-6"

18’-1"

19’-0"

16’-1"

27900

91’-6"

23’-9"

17550

57’-7"

57600

189’-0"

2 3 4 5 6 6.4 6.5 7 8 9 10 111

N

F

G

A

B

D

E

12’-4"

A SCALE : 1 / 100

1ST EXIST / REMOVAL FLOOR PLAN

REMOVAL FLOOR PLAN

1ST EXIST /

A101

EQUIPMENT SCREEN

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

1. REMOVE AND REINSTALL THE EXISTING EXTERIOR LIGHTING FIXTURES WITH

ALL NECESSARY ACCESSORIES ACCORDING TO WORK SCOPE.

2. REMOVE AND REINSTALL THE EXISTING SAFETY SWITCHES WITH ALL NECESSARY

ACCESSORIES ACCORDING TO WORK SCOPE.

3. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPLACE OR REPAIR ALL DAMAGES

TO EXISTING EQUIPMENT, PIPE, AND DUCT ACCORDING TO WORK SCOPE.

4. THE CONTRACTOR SHALL BE RESPONSIBLE TO REMOVE AND REINSTALL

THE OBSTRUCTED ITEMS SUCH EQUIPMENT, PIPE, AND DUCT TO MAKE WAY FOR

THE INSTALLATION AND REPLACEMENT OF WORK.

NOTES:

LEGEND

REMOVE STANDING SEAM METAL ROOFING

REMOVE METAL SHEET OF CANOPY

REMOVE ACOUSTICAL CEILING TILE UNIT

FRAME AND INSULATION

REMOVE FACADE CLADDING PANNEL WALL, SUPPORT

REMOVE INSULATION

REMOVE AND REINSTALL PROTECTED METAL FASCIA WALL

REMOVE PROTECTED METAL FLASHING

REMOVE EXISTING WINDOW

DOWNSPOUT AND CAP FLASHING PARAPET

GUTTER EXPANSION JOINT, METAL CONDUCT HEAD,

REMOVE PROTECTED METAL GUTTER,

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

5 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

VEST-1

HALL

GAME ROOM

BOSS ROOM

PROJECTION

ROOM

W TOILETM TOILET

COMM ROOM

CORRIDOR-2

OFFICE

STORAGE-1

JAN

ELEC ROOM

STORAGE-2

AHU ROOM

TOUR & TRAVEL

CENTER

DIRECTOR

OFFICE

UP

DN

STAIR-2

STAIR-4

STAIR-3

217216

MUSIC ROOM-2

MUSIC ROOM-1

NINTENDO &

PLAYSTATION

GAME ROOM

TV AREA

CORRIDOR-1

STAIR-1

ELEV

VEST-2

DN

UP

DN

COUNTER

UNUSED SPACE

212A

CLOSET

CCTV

UPDN

20’-6"

18’-1"

19’-0"

16’-1"

27900

91’-6"

23’-9"

17550

57’-7"

57600

189’-0"

2 3 4 5 6 6.4 6.5 7 8 9 10 111

N

F

G

A

B

D

E

BRIDGE

A102

A SCALE : 1 / 100102

2ND EXIST / REMOVAL FLOOR PLAN

NOTES:

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

REMOVAL FLOOR PLAN

2ND EXIST /

3. WHERE NEW WORK IS APPLIED TO EXISTING SURFACES, PERFORM REMOVALS

AND PATCHING IN A MANNER TO PRODUCE SURFACES SUITABLE FOR RECEIVING NEW

WORK FLUSH FINISHED SURFACES OF PATCHED AREA WITH ADJACENT EXISTING SURFACE.

4. VERIFY EXISTING CONDITIONS, INFORMATION, AND LOCATION OF OBJECTS CRITICAL

TO THE WORK PRIOR TO COMMENCING WORK.

5. FIELD VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS,AND SIZE / LOCATIONS OF

EXISTING STRUCTURAL ELEMENTS.

6. NO PENETRATIONS ARE ALLOWED IN EXISTING OR NEW BEAMS AND OR COLUMNS.

LEGEND

REMOVE STANDING SEAM METAL ROOFING

REMOVE METAL SHEET OF CANOPY

REMOVE ACOUSTICAL CEILING TILE UNIT

FRAME AND INSULATION

REMOVE FACADE CLADDING PANNEL WALL, SUPPORT

REMOVE INSULATION

REMOVE AND REINSTALL PROTECTED METAL FASCIA WALL

REMOVE PROTECTED METAL FLASHING

REMOVE EXISTING WINDOW

DOWNSPOUT AND CAP FLASHING PARAPET

GUTTER EXPANSION JOINT, METAL CONDUCT HEAD,

REMOVE PROTECTED METAL GUTTER,

1. EXISTING CONSTRUCTION FLOOR PLAN SHOWN BASED UPON FIELD ASSESSMENT.

ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITION TO BE

REPORTED TO THE CONTRACTING OFFICER PRIOR TO PROCEEDING WITH WORK.

2. DEMOLITION AND REPAIR WORK SCHEDULE MUST PERFORMED WITH "DUE CARE AND

DILIGENCE" IN ORDER TO PREVENT ARBITRARY DAMAGE OR INTERRUPTION OF SERVICE.

3. PARTIALLY REMOVE BRICK FACE FINISH FOR AL SHEET REPLACEMENT OF CANOPY

AS REQUIRED AND RESTORE BRICK FACE WALL.

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

6 33

FEC

CCTV

FEC

CHILDREN’S

M TOILET

PERIODICALS

OFFICE

STAFF

READING AREA

CD/DVD

ELEV

STAIR-1

DN

HALL

AHU ROOM

AREA

COMPUTER

COMM ROOM

DN UP

STAIR-2

W TOILET

311 312

VEST-1

JAN

CORRIDOR

ELEC ROOM

DN

STAIR-3

BRIDGE

20’-6"

18’-1"

19’-0"

16’-1"

27900

91’-6"

23’-9"

17550

57’-7"

57600

189’-0"

2 3 4 5 6 6.4 6.5 7 8 9 10 111

N

F

G

A

B

D

E

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

A103

A SCALE : 1 / 100103

3RD EXIST / REMOVAL FLOOR PLAN

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

REMOVAL FLOOR PLAN

3RD EXIST /

LEGEND

REMOVE STANDING SEAM METAL ROOFING

REMOVE METAL SHEET OF CANOPY

REMOVE ACOUSTICAL CEILING TILE UNIT

FRAME AND INSULATION

REMOVE FACADE CLADDING PANNEL WALL, SUPPORT

REMOVE INSULATION

REMOVE AND REINSTALL PROTECTED METAL FASCIA WALL

REMOVE PROTECTED METAL FLASHING

REMOVE EXISTING WINDOW

DOWNSPOUT AND CAP FLASHING PARAPET

GUTTER EXPANSION JOINT, METAL CONDUCT HEAD,

REMOVE PROTECTED METAL GUTTER,

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

7 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

DN

20’-6"

18’-1"

19’-0"

0"

29’-8"

23’-9"

17550

57’-7"

33850

111’-1"

2 3 4 5 6 6.4 6.5 71

N

F

G

A

B

D

E

A104

A SCALE : 1 / 100104

ROOF EXIST / REMOVAL FLOOR PLAN

S S

S S

S S

6432 51 6.4

B

A

C

D

E

F

G

S SSS S S S

STAIR-1

AREA

READING

STAIR-2

CORRIDOR-2

ELEC ROOM

STAIR-3

VEST-2

313 312

W TOILETM TOILET

HALL

AHU ROOM

AREA

CHILDREN’S

COMPUTER

OFFICE STAFF

PERODICALS

A 104

3RD FLOOR CEILING EXIST / REMOVAL PLAN2

SCALE : 1 / 200

TILE SHOULD BE REMAIN EXCEPT FOR L- BAR FACE TO WALL.

2. THE CEILING SUSPENSION FRAME FOR ACOUSTICAL CEILING

CEILING TILES TO THE GOVERNMENT PER DPW REQUIREMENTS.

3. THE CONTRACTOR SHALL RETURN DISASSEMBLED EXST ACOUSTICAL

REINSTALLED AS NECESSARY.

CEILING FRAME DURING WORK, AND COULD BE REMOVED AND

4. THE CONTRACTOR SHALL PREVENT DAMAGE TO THE EXISTING

NOTES:

REFER TO FLOOR PLAN AND FINISH SCHEDULE.

1. THE SCOPE OF All WORK IS APPLIED TO BUILDING PARTS.

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

REMOVAL FLOOR PLAN

ROOF EXIST /

LEGEND

REMOVE STANDING SEAM METAL ROOFING

REMOVE METAL SHEET OF CANOPY

REMOVE ACOUSTICAL CEILING TILE UNIT

FRAME AND INSULATION

REMOVE FACADE CLADDING PANNEL WALL, SUPPORT

REMOVE INSULATION

REMOVE AND REINSTALL PROTECTED METAL FASCIA WALL

REMOVE PROTECTED METAL FLASHING

REMOVE EXISTING WINDOW

DOWNSPOUT AND CAP FLASHING PARAPET

GUTTER EXPANSION JOINT, METAL CONDUCT HEAD,

REMOVE PROTECTED METAL GUTTER,

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

8 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

12’-4"

UP

DN

INDOOR

DN

PLATFORM

122 123

133 134

UP

FEC

FOR WALL

DASHED LINE

FEC

FEC

ELEV

UP

UP

UP

DN

(ABOVE)

DS

DS DS

DS DS

DS

DN

DN

SLOPE 2%

DS

S L O

P E

1/

20’-6"

18’-1"

19’-0"

16’-1"

27900

91’-6"

23’-9"

17550

57’-7"

57600

189’-0"

2 3 4 5 6 6.4 6.5 7 8 9 10 111

N

F

G

A

B

D

E

DASHED LINE FOR

BRIDGE (ABOVE)

SCALE : 1 / 100

NEW 1ST FLOOR PLAN1

A A105

1B

1B

1A

1B

1A

1A

1A

EQUIPMENT SCREEN

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

NEW 1ST FLOOR PLAN

773 10

773 10

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

9 33

GEJ (GUTTER EXPANSION

JOINT)-TYP

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

A SCALE : 1 / 100

NEW 2ND FLOOR PLAN

UP

DN

217216

209 208

SEAM METAL

DS

DASHED LINE FOR

ROOF (ABOVE)

ROOF SLOPE

DN

UP

DN

STANDING SEAM

METAL ROOFING

DS

DS

DSDS

DS DS DS

CURVED STANDING

SEAM METAL 1ST FLOOR

CANOPY (BELOW)

CURVED

2%

(ABOVE)

LINE FOR

WALL

DASHED

DS

212A

UPDN

20’-6"

18’-1"

19’-0"

16’-1"

27900

91’-6"

23’-9"

17550

57’-7"

57600

189’-0"

2 3 4 5 6 6.4 6.5 7 8 9 10 111

N

F

G

A

B

D

E

GEJ

PROTECTED METAL

DOWNSPOUT(TYP)

1B

METAL ROOFING

STANDING SEAM

A106

1E

(TYP)

CONC SPLASH BLOCK

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

NEW 2ND FLOOR PLAN

9 10

773 10

773 10

CURVED STANDING

EXST

ROOFING (TYP)

1B

9 103

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

10 33

DASHED LINE

FOR WALL

(BELOW)

DASHED LINE

FOR ROOF

(ABOVE)

DS DS

DS

CURVED STANDING

SEAM METAL CANOPY

DS

DASHED LINE FOR

ROOF (ABOVE)-TYP

CAP FLASHING

R O

O F

S L O

P E

DS

DN

DS

DN UP

DS

311 312

314 317

DN

R O

O F

S L O

P E

R O

O F

S L O

P E

R O

O F

S L O

P E

R O

O F

S L O

P E

R O

O F

S L O

P E

BRIDGE

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

20’-6"

18’-1"

19’-0"

16’-1"

27900

91’-6"

23’-9"

17550

57’-7"

57600

189’-0"

2 3 4 5 6 6.4 6.5 7 8 9 10 111

N

F

G

A

B

D

E

A SCALE : 1 / 100

NEW 3RD FLOOR PLAN

DS

DS

DS

A107

W1 W2

W2

3AL SHEET

C

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

NEW 3RD FLOOR PLAN

773 10

773 10

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

11 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

A SCALE : 1 / 100

DS

CURVED STANDING

SEAM METAL

ROOFING (TYP)

STANDING SEAM

METAL ROOFING (TYP)

CONDUCT HEAD

(TYP)STAIR-2

PROTECTED MET

FLASHING

STANDING SEAM

METAL ROOFING

(TYP)

CHIMNEY

DN

R O

O F

S L O

P E

P E

R

R O

O F

S L O

P E

ROOF SLOPE

R O

O F

S L O

P E

P E

R

R O

O F

S L O

P E

ROOF SLOPE

W/ PLATFORM

STEEL LADDER

DS

DS

DSGEJ

A

B

D

E

F

G

1 2 3 4 5 6 6.4 7 8 9 10

1"

14’-5"

1’-0"

11’-6"

15’-5"

5’-1"

15800

51’-10"

24800

81’-4"

22’-8"

29’-6"

17350

56’-11"

58050

190’-5"

1’

1’

1’

11’-6"

4’-11"

1’

ROOF EXHAUST PAN PANTHOUSE

VTR

1B

1A

N

A108

1A

1A

1B

1B

1C 1 43

1 43

NOTES:

APPLY PROTECTIVE COATING PER SPECIFICATION.

FASTENERS AS REQUIRED. PREPARE EXPOSED METAL PANELS AS REQUIRED AND

A WEATHERPROOF ROOF MEMBRANE. REPLACE MISSING OR DAMAGED PANEL

5. REPAIR, CLEAN AND RE-SEAL EXISTING METAL ROOF PANELS TO PROVIDE

NEW ROOF COATING.

4. REPAIR, CLEAN AND RE-FINISH EXISTING CHIMNEY TO MATCH

APPLY NEW PROTECTIVE COATING TO MATCH ADJACENT ROOF FINISH.

TO ENSURE OPERATING CONDITION. PREPARE SURFACES AS REQUIRED AND

3. REPAIR EXISTING ROOF HATCH, SAFETY RAILINGS, LADDER AND EXTENSION BAR

WITH SPECIFICATION.

INTERFACES. SEALANT MATERIALS AND APPLICATIONS SHALL COMPLY

2. APPLY NEW SEALANTS TO ALL ROOF JOINTS, GUTTERS AND MATERIAL

PENETRATIONS IN ACCORDANCE WITH SPECIFICATION.

1. REPLACE EXISTING CURBING, TRIM AND ACCESSORIES AT ALL ROOF

LEGEND

STANDING SEAM METAL ROOFING

GUTTER EXPENSION JOINT

DOWNSPOUT

GEJ

DS

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

NEW ROOF PLAN

NEW ROOF PLAN

1A

1A

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

D - 23 - 33

12 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

SCALE : 1 / 100A

A 201

SCALE : 1 / 100

CURVED STANDING SEAM

PANEL (TYP)

FACADE

CLADDING

W/INSUL ON VR (TYP)DOWNSPOUT

PROTECTED METAL

FASCIA WALL PANEL

W/INSUL ON VB (TYP)

1ST FL

2ND FL

3RD FL

GREEN TINTED

INSULATED

GLASS (TYP)

FACADE CLADDING

PANEL (TYP)

W/INSUL ON VR (TYP)

SEAM METAL ROOFING

W/INSUL ON VB (TYP)

FASCIA WALL PANEL

PROTECTED METAL

(BEYOND)

FOR ROOF

DASHED LINE

3RD FL

2ND FL

1ST FL

PANNEL

FACADE CLADDING

(BEYOND)-TYP

FOR WALL

DASHED LINE

DOWNSPOUT

EAST ELEVATION

SOUTH ELEVATION

11109876432 51 6.4 6.5

F GD EA B C

W1 W2

A201

8 8

W1

1C

EXST FACE BRICK

EXST CURVED STANDING

FLOOR DECK (P-5/P-6)

PAINT STEEL TUBE POST, STEEL BEAM PLATE

EXST PROTECTED MET

PROTECTED METAL

FASCIA WALL PANEL

W/INSUL ON VB (TYP)

NOTES:

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

EAST ELEVATION

SOUTH ELEVATION /

9 103

773 10

773 10

9 103

9 103

SST

EXST

METAL ROOFING SYSTEM

MATCH WITH EXST

METAL SURFACE

RECOAT

1212 12 12 12

COATING AND PAINTS PER SPECIFICATION.

RECOAT EXPOSED METAL FINISHES AS REQUIRED AND APPLY PROTECTIVE

MISSING OR DAMAGED PARTS AND SURFACE ON THE DRAWING AS REQUIRED.

TUBE AND STEEL PIPE TO PROVIDE A WEATHERPROOF SURFACE. RE-PAINT

5. CLEAN, RECOAT AND RE-PAINT EXISTING WALL, COLUMN, BEAM, BRACE, STEEL

CONCRETE EXTERIOR BUILDING SURFACE PAINT TO COMPLY WITH SPECIFICATION.

4. APPLY NEW HIGH-BUILD ACRYLIC PAINT FINISH ALL EXPOSED

W/SST GUTTER, DOWNSPOUT-REFER TO FLOOR PLAN FOR DETAILED WORK.

3. REPLACE EXISTING METAL GUTTER, DOWNSPOUT W/CONC SPLASH BLOCKS

OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE HEAT.

BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE WHITE

2. WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL

APPLY FINISH PER SPECIFICATION. (TYPICAL AT EXTERIOR WINDOWS).

1. INSTALL NEW METAL FLASHING AT EXTERIOR WINDOW.

PLATE AND MATERIAL WITH FIELD TOUCH UP AS REQUIRED.

9. PROVIDE ANTI-CORROSIVE FOR METAL PROTECTIVE COATING ON ALL STEEL

APPLY PROTECTIVE COATING PER SPECIFICATION.

WALL PANELS FINISH. PREPARE EXPOSED METAL PANELS AS REQUIRED AND

AS REQUIRED AND APPLY NEW PROTECTIVE COATING TO MATCH ADJACENT

OR DAMAGED PANEL FASTENERS AS REQUIRED. PREPARE SURFACES

FASCIA WALL PANELS TO PROVIDE DAMP PROOFING. REPLACE MISSING

8. REPAIR, CLEAN, RE-SEAL AND RECOAT EXISTING PROTECTED METAL

NEW WALL PANELS COATING.

7. REPAIR, CLEAN AND RE-FINISH EXISTING CHIMNEY TO MATCH

CANOPY AS REQUIRED AND RESTORE BRICK FACE WALL.

6. PARTIALLY REMOVE BRICK FACE FINISH FOR AL SHEET REPLACEMENT OF

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

D - 23 - 33

13 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

SCALE : 1 / 100A

A

SCALE : 1 / 100

W/INSUL ON VR (TYP)

SCUTTLE

PROTECTED METAL

FASCIA WALL PANEL

W/INSUL ON VB (TYP)

JOINT (TYP)

WALL CONTROL

METAL FASCIA

FL

1ST

FL

2ND

3RD FL

FINISH SYSTEM

METAL CANOPY (TYP)

CURVED STANDING SEAM

BLDG (BEYOND)

DASHED LINE FOR

FINISH SYSTEM

PANEL

FACADE

CLADDING

W/INSUL ON VR

CURVED STANDING SEAM

METAL ROOFING

3RD FL

2ND FL

1ST FL

WEST ELEVATION

NORTH ELEVATION

11 10 9 8 7 6 4 3 25 16.46.5

FG DE ABC

W2

A202

5 13

EIFS BACKGROUND COLOR)-TYP

PAINT CONC (COLOR: MATCH TO

EXST INSUL &

12EXST INSUL &

EXST BRICK FACE

FLOOR DECK (P-5/P-6)

PAINT STEEL TUBE POST, STEEL BEAM PLATE

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

AS SHOWN

WEST ELEVATION

NORTH ELEVATION /

1. REMOVE AND REINSTALL THE EXISTING EXTERIOR LIGHTING FIXTURES WITH

ALL NECESSARY ACCESSORIES ACCORDING TO WORK SCOPE.

2. REMOVE AND REINSTALL THE EXISTING SAFETY SWITCHES WITH ALL NECESSARY

ACCESSORIES ACCORDING TO WORK SCOPE.

3. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPLACE OR REPAIR ALL DAMAGES

TO EXISTING EQUIPMENT, PIPE, AND DUCT ACCORDING TO WORK SCOPE.

4. THE CONTRACTOR SHALL BE RESPONSIBLE TO REMOVE AND REINSTALL

THE OBSTRUCTED ITEMS SUCH EQUIPMENT, PIPE, AND DUCT TO MAKE WAY FOR

THE INSTALLATION AND REPLACEMENT OF WORK.

NOTES:

773 10

9 103

773 10

STEEL LADDER

EXST

ROOF

EXST

CHIMNEY

12 12 12 12

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

14 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

1ST FL

2ND FL

3RD FL

3RD FL

2ND FL

1ST FL

11109876432 51 6.4 6.5

F GD EA B C

A SCALE : 1 / 100

EXTERIOR WALL PLAN - 11

1A EAST

SOUTH1B

A203

1’

1’

1’

17867

58’-7"

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

EXTERIOR WALL PLAN - 1

SCOPE OF WORK SCOPE OF WORK

PROTECTED METAL FASCIA WALL

FACADE CLADDING PANNEL WALL

EQUIPMENT SCREEN WALL

1212 11 2 3 5

SCOPE OF WORK FOR WALL, ROOF AND ACCESSORIES (REFER TO FLOOR PLAN FOR OTHER SOWS)

TYPE

TYPE

STEEL TUBE AND STEEL PIPE

CONC WALL, COLUMN, BEAM, BRACE,

DOWNSPOUT AND FLASHING

PROTECTED METAL GUTTER, CONDUCT HEAD,

ROOF, CANOPY

9 103

773 10

FACE TO ROOF

PROTECTED METAL FLASHING

BRIDGE AREA 1212

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

15 33

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

3RD FL

2ND FL

1ST FL

FG DE ABC

FL

1ST

FL

2ND

3RD FL

11 10 9 8 7 6 4 3 25 16.46.5

A SCALE : 1 / 100

EXTERIOR WALL PLAN - 21

1A WEST

NORTH1B

A204

PAK, SIN YOL

KIM, CHI SOP

CAMP CARROLL

ARCHITECTURAL

17 JUL 23

EXTERIOR WALL PLAN - 2

SCOPE OF WORK SCOPE OF WORK

PROTECTED METAL FASCIA WALL

FACADE CLADDING PANNEL WALL

EQUIPMENT SCREEN WALL

1212 11 2 3 5

SCOPE OF WORK FOR WALL, ROOF AND ACCESSORIES (REFER TO FLOOR PLAN FOR OTHER SOWS)

TYPE

TYPE

STEEL TUBE AND STEEL PIPE

CONC WALL, COLUMN, BEAM, BRACE,

DOWNSPOUT AND FLASHING

PROTECTED METAL GUTTER, CONDUCT HEAD,

ROOF, CANOPY

9 103

773 10

FACE TO ROOF

PROTECTED METAL FLASHING

BRIDGE AREA 1212

HR-00513-9J

REPAIR ROOF AND EXTERIOR WALL AT B139

16 33

2620 (MIN)2620 (MIN)

S P

A N

D R

E L

G

L A S S

(T Y P

T

IN

T E

D

G L A S S

(T Y P

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DI…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .