Drawing.pdf
PDF 1 MB Posted
- Solicitation number
- W90VN923R0121
About this file
This document contains drawings and plans for building waterproofing (leak prevention) work at Building #214 at Camp Walker. The drawings depict the project location, existing conditions, proposed work areas including a underground substation, sidewalk replacement, and grass installation. The related federal contract opportunity is solicitation number W90VN923R0121 from the Department of the Army Materiel Command Army Contracting Command seeking offers for waterproofing services at Building #214 to prevent leaks. The drawings provide details of the scope of work required including membrane replacement, concrete work, painting, and landscaping. Offerors would use this information to understand the requirements and prepare proposals for the solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W90VN923R0121.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HGFEDCBA
392391
KELLY FIELD
Golf Course
Tennis Court
DRIVING
RANGE
Golf Course
Golf Course
Golf Course
SKATE
PARK
661662
PENNSYLVANIA AVENUE
W I S
C O
N S I N
S
T R
E E
T
IN
DI
ANA
AVENUE
W
IS
C O
N S
IN
S T R E E T
U T
A H
S T R E E T
GEORGIA STREET
T E
X A S
S T
R E E T
R H
O D
E
IS
L A
N D
S
T R
E E
T T
E X
A S
S
T R
E E
T
WASHINGTON STREET
C A L
IF
O R
N
IA
S T
R E E T
GEORGIA STREET
N E
B R
A S
K A
S
T R
E E
T
C A L
IF
O R
N
IA
S T
R E E T
R H
O D
E
IS
L A
N D
S
T R
E E
T
P E N N S Y L V A N
IA
A V E N U E
GEORGI
A
STREET
T E
X A S
S T
R E E T
Substation
Gate #6
Gate #4
SHEET 1 OF 7
BLDG# 214, CAMP WALKER
THIS PROJECT
LOCATION PLAN
LOCATION: BLDG# 214, CAMP WALKER
FEWR NO: J1-10063-2J
HGFEDCBA
SHEET 2 OF 7
SUBSTATION
TENNIS COURT205
ENLARGED PLAN
HGFEDCBA
SUBSTATION
UNDERGROUND
SHEET 3 OF 7
TENNIS COURT205
SIZE: 5M WIDE X 11M LONG
RELOCATE SCUD BUNKER WITH CONCRETE BARRIERS
: IT’S ENOUGH SPACE
NEW PLACE (RED MARKED)
SIZE : 5M WIDE X 11M LONG
CURRENT PLACE
SCUD BUNKER PLAN
HGFEDCBA
SUBSTATION
UNDERGROUND
SHEET 4 OF 7
(WALL AREA/TOP AREA)
MEMBRANES AT DESIGNATED AREA
REPLACE WATERPROOFING
2. CONTRACTOR SHALL EXCAVATE THE GROUND TO AVOID DAMAGING UNDERGROUND UTILITY LINES OR MISCELLANEOUS PARTS OF UNDERGROUND
1. CONTRACTOR SHALL VERIFY THE LOCATION OF UTILITY LINES
DURING CONSTRUCTION,
- NOTE -
TENNIS COURT205
WATERPRROFING PLAN
HGFEDCBA
SUBSTATION
UNDERGROUND
SHEET 5 OF 7
30LM X 1.2M WIDE
REPLACE CONCRETE SIDEWALK
2. CONTRACTOR SHALL EXCAVATE THE GROUND TO AVOID DAMAGING UNDERGROUND UTILITY LINES OR MISCELLANEOUS PARTS OF UNDERGROUND
1. CONTRACTOR SHALL VERIFY THE LOCATION OF UTILITY LINES
DURING CONSTRUCTION,
- NOTE -
TENNIS COURT205
SIDEWALK PLAN
HGFEDCBA
SUBSTATION
UNDERGROUND
SHEET 6 OF 7
LEGEND
: PAINT EXTERIOR SURFACE AS CURRENTLY SAME TYPE
: PAINT INTERIOR SURFACE EXCLUDING CEILING AS CURRENTLY SAME TYPE
TENNIS COURT205
PAINT PLAN
HGFEDCBA
SHEET 7 OF 7
REINSTALL GRASS ON THE GROUND (500SM)
REMOVE EXISTING GRASS,
2. CONTRACTOR SHALL EXCAVATE THE GROUND TO AVOID DAMAGING UNDERGROUND UTILITY LINES OR MISCELLANEOUS PARTS OF UNDERGROUND
1. CONTRACTOR SHALL VERIFY THE LOCATION OF UTILITY LINES
DURING CONSTRUCTION,
- NOTE -
TENNIS COURT205
GRASS PLAN
| S1 |
| S2 |
| S3 |
| s4 |
| s5 |
| s6 |
| s7 |
File details come from the government source that posted it. Updated .