Drawing 585.pdf

PDF 279 KB Posted

Attached to
Rehabilitation of a Lagoon, Horton, Kansas
Solicitation number
246-24-Q-0010
Issued by

About this file

This document contains drawings and specifications for the rehabilitation of a septic system lagoon located at 3 bdrm Home in Horton, Kansas. The work includes removing trees within the lagoon fence and disposing them off site, re-stretching the lagoon fence and re-setting steel T-posts, repairing a cleanout riser, cleaning and inspecting a 1,000 gallon septic tank, installing a 24" septic tank riser and lid, and shaping berms. The related federal contract opportunity is a solicitation from the Department of Health and Human Services Indian Health Service seeking these rehabilitation services for the lagoon in Horton, Kansas, under solicitation number 246-24-Q-0010. The drawings were created by the Holton Field Office of the Indian Health Service Office of Environmental Health and Engineering.

View the file

Other files

File Type Posted
ks37.txt TXT text file
585 SOW.docx DOCX document
SF18-95a Request for Quotations and Clauses.pdf PDF
585 Bid Sheet.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SSL

SSL

SSL X

X

X

X

X

X

X

X

M

P P

P

P P P

896 140th St. Horton, KS 66439

3 bdrm Home

1-WAY

CLEANOUT

1-WAY

CLEANOUT

RISER TO BE

REPAIRED

LAGOON FENCE

TO BE RE-STRETCHED

AND T-POSTS TO BE

RE-SET.

TREES TO BE REMOVED

FROM WITHIN LAGOON

FENCE AND BERMS TO BE

RE-SHAPED.

1,000 GALLON

SEPTIC TANK TO

BE CLEANED AND

INSPECTED

LATITUDE: 39DD 42MM 40.4892SS

LONGITUDE: -95DD38MM 24.522SS

SCOPE OF WORK:

REMOVE TREES WITHIN LAGOON

FENCE AND DISPOSE OF OFF SITE.

RE-STRETCH LAGOON FENCE AND

RE-SET STEEL T-POSTS.

REPAIR CLEANOUT RISER.

CLEAN SEPTIC TANK AND INSPECT

FOR ANY DEFECTS.

INSTALL SEPTIC TANK RISER AND

LID.

Water Meter

INSTALL 24" SEPTIC

TANK RISER AND LID

IN

D

I A N

HEA LTH SER

V

ICE

1 9 5 5

NOT TO SCALE

AutoCAD SHX Text

INDIAN HEALTH SERVICE

AutoCAD SHX Text

OFFICE OF ENVIRONMENTAL

AutoCAD SHX Text

SANITATION FACILITIES CONSTRUCTION

AutoCAD SHX Text

HEALTH & ENGINEERING

AutoCAD SHX Text

LAYOUT NAME:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJ ENG:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text 324 New York Ave., Holton, Kansas 66436 (785)364-4164

AutoCAD SHX Text

HOLTON FIELD OFFICE

AutoCAD SHX Text Lagoon Rehabilitation for Service Request # 585 S Wakole

AutoCAD SHX Text

OK 22-I24

AutoCAD SHX Text 7/10/2023

AutoCAD SHX Text

NTS

AutoCAD SHX Text Jim Shane

AutoCAD SHX Text Ted Schlueter

AutoCAD SHX Text Ted Schlueter