The document appears to be a draft update for security camera drawings related to a Department of Veterans Affairs project. The associated federal contract opportunity (Solicitation Number 36C26026R0025) is currently in the pre-solicitation phase, specifically for updating a security camera system at a location associated with Toni Knight. The opportunity is being managed by the Veterans Health Administration Veterans Integrated Service Network 20 (VISN 20). While the specific details of the security camera drawing updates are not fully elaborated in the provided information, the document suggests this is a preparatory stage for a potential security infrastructure enhancement project within a VA facility.

View the file

Other files

File Type Posted
36C26026R0025.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAFT

UPDATE SECURITY CAMERA SYSTEM,

ROSEBURG VA MEDICAL CENTER

SOLICITATION NO. 36C26024R007

VA PROJECT NO. 653-25-103

913 NW Garden Valley Blvd Roseburg, Oregon 97471

IF SHEET MEASURES LESS THAN 30x42 IT IS A

REDUCED PRINT. ADJUST SCALE ACCORDINGLY

VA U.S. Department of Veterans Affairs

LOCATION MAP:

219 Marion St North Bend, Oregon 97459

840 Railroad St Brookings, Oregon 97415

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

04.08.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

G-000

COVER SHEET

LOCATION MAP:

Sheet List Table Sheet Number Sheet Title

G-000 COVER SHEET

E-RB-001 ROSEBURG LEGEND, NOTES AND ABBREVIATIONS

E-RB-101 ROSEBURG - SITE PLAN - NORTH

E-RB-102 ROSEBURG - SITE PLAN - SOUTH

E-RB-201 ROSEBURG BLDG 1 - FL1 - FLOOR PLAN 1

E-RB-202 ROSEBURG BLDG 1 - FL1 - FLOOR PLAN 2

E-RB-203 ROSEBURG BLDG 1 - FL1 - FLOOR PLAN 3

E-RB-204 ROSEBURG BLDG 1 - FL1 - FLOOR PLAN 4

E-RB-205 ROSEBURG BLDG 1 - FL1 - FLOOR PLAN 5

E-RB-206 ROSEBURG BLDG 1 - FL1 - FLOOR PLAN 6

E-RB-207 ROSEBURG BLDG 1 - FL2 - FLOOR PLAN 1

E-RB-208 ROSEBURG BLDG 1 - FL2 - FLOOR PLAN 2

E-RB-209 ROSEBURG BLDG 1 - FL2 - FLOOR PLAN 3

E-RB-210 ROSEBURG BLDG 1 - FL3 - FLOOR PLAN

E-RB-211 ROSEBURG BLDG 1 - FL4 - FLOOR PLAN

E-RB-212 ROSEBURG BLDG 1 - FL5 - FLOOR PLAN

E-RB-213 ROSEBURG BLDG 2 - FL1 FLOOR PLAN

E-RB-214 ROSEBURG BLDG 2 - FL2 - FLOOR PLAN

E-RB-215 ROSEBURG BLDG 2 - FL3 - FLOOR PLAN

E-RB-216 ROSEBURG BLDG 3 - FLOOR PLAN

E-RB-217 ROSEBURG BLDG 4 & 5 - FLOOR PLAN

E-RB-218 ROSEBURG BLDG 6 - FLOOR PLAN

E-RB-220 ROSEBURG BLDG 11 - FLOOR PLAN

E-RB-219 ROSEBURG BLDG 10 - FLOOR PLAN

E-RB-221 ROSEBURG BLDG 13 - FLOOR PLAN

E-RB-222 ROSEBURG BLDG 16 FL1- FLOOR PLAN

E-RB-223 ROSEBURG BLDG 17 FL1 - FLOOR PLAN

E-RB-224 ROSEBURG BLDG 57 & 58 - FLOOR PLAN

E-RB-225 ROSEBURG BLDG 60 61 62 & 64 - FLOOR PLAN

E-RB-226 ROSEBURG BLDG 65 - FLOOR PLAN

E-RB-227 ROSEBURG BLDG 71 BASEMENT- FLOOR PLAN

E-RB-228 ROSEBURG BLDG 71 FL1- FLOOR PLAN

E-RB-229 ROSEBURG BLDG 72 & 76 - FLOOR PLAN

E-RB-230 ROSEBURG BLDG 81 - FLOOR PLAN

E-RB-231 ROSEBURG BLDG 82 & 84 - FLOOR PLAN

E-RB-232 ROSEBURG BLDG 85 - FLOOR PLAN

E-RB-233 ROSEBURG BLDG 86 - FLOOR PLAN

E-RB-234 ROSEBURG BLDG 87 - FLOOR PLAN

E-RB-235 ROSEBURG BLDG 88 - FLOOR PLAN

E-NB-236 NORTH BEND - FL1 - FLOOR PLAN

E-BK-237 BROOKINGS - FL1 - FLOOR PLAN

E-RB-401 ROSEBURG MAIN RACK ELEVATION

E-NB-402 NORTH BEND MAIN RACK ELEVATION

E-BK-403 BROOKINGS MAIN RACK ELEVATION

E-500 EXISTING NETWORK RISER

E-501 NEW RISER NORTH BEND

E-502 NEW RISER BROOKINGS

E-600 VIEW STATION - OPTION 1

E-700 DETAILS

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

4/4/2025

Final Design Construction Documents

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

E-RB-001

ROSEBURG LEGEND, NOTES AND

ABBREVIATIONS

A AMP

AA AUTOMATIC ALTERNATOR

AC ALTERNATING CURRENT

ACU AIR CONDITIONER UNIT

AF AMPERAGE FRAME

AFF ABOVE FINISHED FLOOR

ANN ANNUNCIATOR

AS AMMETER SWITCH

AT AMPERE TRIP

AX AUXILIARY DELAY

BKR BREAKER

CB CIRCUIT BREAKER

COL COLUMN

CL CENTERLINE

CKT CIRCUIT

CF(P OR L) CLOSE ON FALLING

(PRESSURE OR LEVEL)

CR(P OR L) CLOSE ON RISING

(PRESSURE OR LEVEL)

CH CONVECTION HEATER

COMPT COMPARTMENT

COND CONDUCTOR

CDT CONDUIT

C-( ) CONTRACT-( ) ID

CPT CONTROL POWER

TRANSFORMER

CR-( ) CONTROL RELAY-( ) ID

I/I CURRENT TO CURRENT

TRANSDUCER

I/P CURRENT TO PNEUMATIC

TRANSDUCER

CT CURRENT TRANSFORMER

D EXISTING TO BE DEMOLISHED

DC DIRECT CURRENT

DF DUST FILTER

DIA DIAMETER

DISTR DISTRIBUTION

DP DIFFERENTIAL PRESSURE

DS DISCONNECT SWITCH

DPDT DOUBLE POLE, DOUBLE THROW

E EXISTING TO REMAIN

EN EXISTING TO BE REPLACED

WITH NEW

EBB ELECTRIC BASED BOARD

EC ELECTRICAL CONTRACTOR

ECH ELECTRIC CEILING HEATER

EDH ELECTRIC DUCT HEATER

EF ELECTRIC FAN

EMT ELECTRIC METALLIC TUBING

ER EXISTING TO BE REMOVED AND

RELOCATED

ETM ELAPSED TIME METER

EUH ELECTRIC UNIT HEATER

EWC ELECTRIC WATER COOLER

F FLOW

FDR FEEDER

FLA FULL LOAD AMPS

FMC FLEXIBLE METALLIC CONDUIT

FOS FAST-OFF-SLOW

F-S FAST-SLOW

FT FEET

F-R FORWARD REVERSE

FR FRAME

FUSS FUSED SAFETY SWITCH

FVNR FULL VOLTAGE

NON-REVERSING

G GREEN

GFCI GROUND FAULT CIRCUIT

INTERRUPTER

GPM GALLONS PER MINUTE

GND GROUND

GRV GRAVITY RELIEF VENT

GUH GAS UNIT HEATER

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HV HOUSE VACUUM

HZ HERTZ

ID IDENTIFICATION NUMBER

IC INTERRUPTING CAPACITY

IF INFRARED HEATER

IMC INTERMEDIATE METAL

CONDUIT

INF IN LINE FAN

I/O INPUT/OUTPUT

IT INTERCHANGEABLE TRIP OR

INSTANTANEOUS TRIP

JB JUNCTION BOX

kcmil THOUSAND CIRCULAR MILS

KUH/EUH ELECTRIC UNIT HEATER

KVA KILOVOLT AMPERE

KV KILOVOLT

KVAR KILOVOLT AMPERES REACTIVE

KW KILOWATT

L LEVEL

LC LOUVER CONTROLLER

LFMC LIQUID-TIGHT FLEXIBLE

METAL CONDUIT

LM LOUVER MOTOR

LP( )-( ) LIGHTING CIRCUIT ( )

LP( ) LIGHTING PANELBOARD

LS LIMIT SWITCH

LV LOUVER

M MANUAL MOTOR STARTER

mA MILLIAMPERES

MC METAL CLAD CABLE

MCC MOTOR CONTROL CENTER

MCP MOTOR CIRCUIT PROTECTOR

MEZZ MEZZANINE

MF-( ) MAIN FEEDER-( ) ID

MGD MILLION GALLONS PER DAY

MS MOTOR STARTER

MTD MOUNTED

MTR MOTORIZED TIMING RELAY

MUAU MAKE UP AIR UNIT

MX MOTOR AUXILIARY RELAYS

(N) NEW

NAC NOTIFICATION APPLIANCE

CIRCUIT

NP NAMEPLATE

NF NON FUSED

NFSS NON FUSED SAFETY SWITCH

N.C. NORMALLY CLOSED

N.O. NORMALLY OPEN

No. NUMBER

( )OL OVERLOAD ( ) NUMBER OF

P PRESSURE

( )P POLES ( ) NO OF POLES

Ø or PH PHASE

P/I PNEUMATIC TO CURRENT

TRANSDUCER

PLC PROGRAMMABLE LOGIC

CONTROLLER

POE POWER OVER ETHERNET

PRE POWER ROOF EXHAUSTER

PS PRESSURE SWITCH

PT POTENTIAL TRANSFORMER

PTAC PACKAGE TERMINAL

AIR CONDITIONER

PTR PNEUMATIC TIMING RELAY

PVC POLYVINYL CHLORIDE

RIGID CONDUIT

PVC-RSC PVC COATED RIGID

STEEL CONDUIT

PWV POWER WALL VENTILATOR

QTY QUANTITY

R RELOCATED

RAC RIGID ALUMINUM

RECPT RECEPTACLE

REQ REQUIRED

RMS ROOT MEAN SQUARE

RGS RIGID STEEL CONDUIT

RTU REMOTE TERMINAL UNIT

SAF SUPPLY AIR FAN

STP SHIELDED TWISTED PAIR

SL STOP LOCKOUT

SMC SMART MOTOR CONTROLLER

SPDT SINGLE POLE, DOUBLE THROW

SS SELECTOR SWITCH

S/S START/STOP

S/SL START/STOP LOCKOUT

SV SOLENOID VALVE

SYM SYMMETRICAL

T or T'STAT THERMOSTAT

T-( ) TELEPHONE CONDUIT-( )

TCC TIME-CLOSE CONTACT

TEMP TEMPERATURE

TC TEMPERATURE CONTRACTOR

TOC TIME-OPEN CONTACT

TR TIMING RELAY

TRI SHIELDED TRIPLE CABLE

TS TEMPERATURE SWITCH

TSP TWISTED SHIELDED PAIR

TYP TYPICAL

UF UNDERGROUND FEEDER

UH UNIT HEATER

VA VOLT - AMPERE

VAC VOLTS ALTERNATING CURRENT

VDC VOLTS DIRECT CURRENT

VFD VARIABLE FREQUENCY DRIVE

VS VOLTMETER SWITCH

VT VOLTAGE TRANSFORMER

W WATT

WH WATER HEATER

WP WEATHERPROOF

1. THIS IS A COMPLETE LIST OF ELECTRICAL SYMBOLS AND ABBREVIATIONS FOR

REFERENCE ONLY. SYMBOLS SHOWN ON THIS DRAWING MAY NOT APPEAR ON THE

FOLLOWING DRAWINGS.

2. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED SHUTDOWNS ON EXISTING

UTILITIES WITH OWNER REPRESENTATIVES IN ORDER TO MINIMIZE IMPACT TO OTHER

AREAS.

3. PERFORM ALL WORK IN COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL

CODES, REGULATIONS, AND STANDARDS ADOPTED BY THE AUTHORITY HAVING

JURISDICTION. IF CONFLICTS EXIST BETWEEN THESE ENGINEERING DOCUMENTS AND

CODES, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN.

4. ALL CONSTRUCTION WORK SHALL ALSO MEET THE FOLLOWING CODE REQUIREMENTS:

· NFPA 101-2018, THE LIFE SAFETY CODE

· NFPA 70-2017, NATIONAL ELECTRICAL CODE

· NFPA 72-2016, NATIONAL FIRE ALARM CODE

5. THE ELECTRICAL DRAWINGS ARE SCHEMATIC IN NATURE. BEFORE STARTING THE WORK

THE CONTRACTOR SHALL REVIEW ALL OTHER DISCIPLINE DRAWINGS AND VERIFY FIELD

CONDITIONS AND SHALL MAKE ANY REQUIRED MINOR ADJUSTMENTS WITHOUT EXTRA

COST TO THE OWNER. ANY MAJOR DISCREPANCIES FOUND SHALL BE BROUGHT TO THE

ATTENTION OF THE ARCHITECT/ENGINEER.

6. ALL WIRING SHALL BE IN CONDUIT. MINIMUM CONDUIT SIZE SHALL BE 3/4". MINIMUM

CONDUCTOR SIZE SHALL BE #12 AWG. ALL NEW CIRCUITS SHALL BE PROVIDED WITH AN

INDIVIDUAL NEUTRAL AND GROUNDING CONDUCTOR WITH THE PHASE CONDUCTOR.

7. ALL CONDUITS INSTALLED INTERIOR SHALL BE EMT. ALL CONDUITS INSTALLED EXTERIOR

UNDERGROUND SHALL BE PVC SCHEDULED 40. ALL CONDUITS INSTALLED EXTERIOR AND

EXPOSED SHALL BE RGS.

8. CONDUCTORS #10 AND SMALLER SHALL BE SOLID COPPER. CONDUCTORS #8 AND

LARGER SHALL BE STRANDED COPPER. UNLESS NOTED OTHERWISE, CONDUCTORS

INSULATION SHALL BE DUAL RATED AT THHN/THWN.

9. ALL DEVICES, EQUIPMENT MATERIAL AND LABOR SHALL BE PROVIDED BY THE

CONTRACTOR UNLESS NOTED OTHERWISE.

10. ALL ELECTRICAL EQUIPMENT AND DEVICES SHALL BE MOUNTED AS PER EQUIPMENT AND

DEVICE MANUFACTURER RECOMMENDATIONS.

11. CONTRACTOR SHALL PROVIDE SUBMITTALS TO ARCHITECT/ENGINEER FOR REVIEW AND

APPROVAL OF ALL ELECTRICAL EQUIPMENT AND DEVICES DESCRIBED IN THE SUBMITTAL

REGISTER. SUBMITTALS SHALL INCLUDE CUT SHEETS, DIMENSIONS, WIRING DIAGRAMS,

ACCESSORIES, OPERATION MANUALS, AND ALL NECESSARY INFORMATION FOR

REVIEWER TO MAKE A SOUND EVALUATION.

12. PROVIDE STARTUP OF ALL ELECTRICAL SYSTEMS AND COORDINATE WITH

ARCHITECT/ENGINEER FOR OWNER STARTUP WITNESSING.

13. PROVIDED LAMINATED PLASTIC NAMEPLATES FOR EACH EQUIPMENT ENCLOSURE. EACH

NAMEPLATE IDENTIFY EQUIPMENT FUNCTION, PANELBOARD CONNECTED AND CIRCUIT

NUMBER. NAMEPLATE SHALL BE MELAMINE PLASTIC (0.125 INCHES THICK), WHITE

LETTERS ON BLACK BACKGROUND. MINIMUM SIZE OF LETTERS SHALL BE 2.5 INCHES. IN

ADDITION TO EQUIPMENT TAGGING, CONTRACTOR SHALL PROVIDE ARC-FLASH WARNING

AND AVAILABLE FAULT CURRENT AT THE TIME OF INSTALLATION AND CALCULATION

LABELS FOR PANELBOARDS, OTHER THAN DWELLING UNIT LOAD CENTERS, IN

ACCORDANCE WITH NEC 110.

14. PROVIDE PUNCHED TAPE LABELS ON ALL WIRING DEVICES FOR IDENTIFICATION. SHALL BE

½” BLACK TAPE WITH WHITE RAISED LETTERS. TAPE LABELS SHALL STATE PANELBOARD

NAME AND CIRCUIT NUMBER.

15. PROVIDE DIRECTORIES ON ALL PANELBOARDS. ALL LOADS SHALL BE BALANCED TO

WITHIN 10%.

16. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A COMPLETE SET OF RECORD

DRAWINGS TO THE OWNER AT THE END OF THE CONSTRUCTION.

17. ALL MATERIALS AND EQUIPMENT TO BE INSTALLED SHALL BE NEW AND FREE OF DEFECTS.

ALL ELECTRICAL EQUIPMENT SHALL COMPLY WITH NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION (NEMA) STANDARDS AND SHALL BE UL LABELED. ALL

ELECTRICAL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN A WORKMANLIKE

MANNER.

18. ALL CONNECTORS AND SPLICES FOR CABLE SIZE #10 AWG AND SMALLER SHALL BE

INSULATED, PRESSURE-TYPE. FOR LARGER SIZE CONDUCTORS USE BOLTED CLAMPS

WITH INSULATING TAPE.

19. UNLESS OTHERWISE NOTED BY THE AUTHORITY HAVING JURISDICTION, ALL NEW

CAMERAS SHALL BE PROVIDED WITH SEISMIC BRACING/SUPPORT. PROVIDE ALL

MOUNTING PLATES, BRACING BRACKETS AND SUPPORT CABLES REQUIRED FOR A

COMPLETE INSTALLATION. VERIFY SITE CONDITIONS PRIOR FINAL PROJECT COST BID

SUBMITTAL.

COMMUNICATION SYMBOLS LEGEND

(MOUNTING HEIGHT TO CENTER LINE OF BOX UNLESS NOTED OTHERWISE)

KEY NOTE INDICATOR

DRAWING REVISION INDICATORX

X X X X

LINE TYPES

NEW WORK SCOPE OF WORK

EXISTING SCOPE OF WORK

DEMOLITION SCOPE OF WORK

FUTURE SCOPE OF WORK

CONDUIT AND WIRING

2A-1,3,5

BRANCH CIRCUIT RUN CONCEALED

BRANCH CIRCUIT RUN UNDER FLOOR

BRANCH CIRCUIT DOWN

BRANCH CIRCUIT UP

HOME RUN TO PANEL 2A SPACES 1, 3, & 5, REFER TO PANEL

SCHEDULES

TELECOM DATA RACK

360 DEGRESS EXTERIOR VIDEO SURVEILLANCE CAMERA

1. CAMERA SHALL BE SET UP TO START RECODING WHEN MOTION

IS DETECTED, UNLESS OTHERWISE NOTED BY THE VA.

3. CAMERA SET UP FOR VIEWING AT LEASED SITE, ROSEBURG AND

ANY OTHER LOCATION IDENTIFIED BY CONTRACT OFFICER

REPRESENTATIVE. GENERAL CONTRACTOR SHALL INCLUDE IN

BID TO COORDINATE WORK IN THE TELECOM ROOMS WHILE

BEING ESCORTED BY VA PERSONNEL.

4. ALL CAMERAS SHALL BE PRE-PROGRAMMED WITH STATIC IP

ADDRESS THAT WILL PROVIDED BY OIT OR ENGINEERING STAFF

BEFORE CAMERAS CAN BE CONNECTED TO OIT VA INFORMATION

TECHNOLOGY (IT)/TELECOM ROOM (TR).

5. THE GENERAL CONTRACTOR SHALL EVALUATE THE SERVICE

PROVIDED BANDWIDTH AVAILABLE AT THIS LOCATION AND

NOTIFY LOCAL VA IF CURRENT ALLOCATION NEEDS TO BE

UPGRADED TO SUPPORT NEW CAMERAS REMOTE CONNECTION.

GENERAL CONTRACTOR AND

SYSTEM INTEGRATOR NOTES

SCALE:1 REMOTE CENTRAL HEAD END LOCATION

N/A

ELECTRICAL ABBREVIATIONS GENERAL PROJECT NOTESGENERAL SYMBOLS

360 DEGRESS INTERIOR VIDEO SURVEILLANCE CAMERA

180 DEGRESS EXTERIOR VIDEO SURVEILLANCE CAMERA

180 DEGRESS INTERIOR VIDEO SURVEILLANCE CAMERA

INTERIOR VIDEO SURVEILLANCE CAMERA

EXTERIOR VIDEO SURVEILLANCE CAMERA

SPECIAL VIDEO SURVEILLANCE CAMERA

LOCATION OF CENTRAL

COMMAND

EXISTING SYSTEM, CONTRACTOR SHALL ADD LICENSES AND EXPAND

STORAGE, AS NECESSARY TO SUPPORT THIS PROJECT.

NEW EQUIPMENT SHALL MATCH EXISTING. WHERE SPECIFIC MODELS

HAVE REACHED END OF LIFE, THE REPLACEMENT MODEL SHALL BE

USED.

THIS PROJECT INVOLVES LIVE SYSTEMS. INSTALLATION SHALL BE

PHASED SUCH THAT SYSTEMS ARE RESTORED AT THE END OF EACH

WORK DAY.

INTERIOR/EXTERIOR VIDEO SURVEILLANCE CAMERA

EXISTING TO REMAIN

E

INTERIOR/EXTERIOR VIDEO SURVEILLANCE CAMERA

EXISTING, REPLACE WITH NEW

E

ENEN

INTERIOR/EXTERIOR VIDEO SURVEILLANCE CAMERA

NEW CAMERANN

INTERIOR/EXTERIOR VIDEO SURVEILLANCE CAMERA

NEW PSRDM REQUIRED CAMERA TO BE PROVIDED IN THE

FUTURE BUT TO BE ACCOUNTED FOR ON THE SERVER.PP

SCOPE OF WORK

PROJECT SUMMARY:

THE INTENT OF THE PROJECT IS TO UPDATE THE MAIN HEADED HARDWARE AT ROSEBURG

VA TO FIX CURRENT ISSUED AND PROVIDE ANALYTIC CAPABILITY, WHILE AT THE SAME

TIME ALLOW THE LOCATION OF BROOKINGS AND NORTH BEND CBOC TO BE REVIEW AND

ACCESSED REMOTELY.

ALL DEVICES SHALL BE PROVIDED WITH AN CERTIFICATE OF BUY AMERICAN ACT

COMPLIANCE CERTIFICATE. ALL DEVICES SHALL BE VA NETWORK CERTIFIED.

CONTRACTOR SHALL INCLUDE IN PROJECT BID THE DELIVERY OF EQUIPMENT TO SITE,

SITE STAGING, LABOR, TESTING, WIRING, LABELING, PROGRAMING, LICENSES,

TRAINED/CERTIFIED PERSONNEL, COMMISSIONING, HARDWARE AND SOFTWARE FOR A

COMPLETE AND FULLY FUNCTIONAL INSTALLATION AS DEFINED AND/OR NOTED BY THE

VA. WORK INSIDE THE TELECOM ROOMS IS EXPECTED TO BE PERFORMED UNDER DIRECT

SUPERVISION OF VA PERSONNEL.

ROSEBURG CAMERA CAPABILITY SUMMARY

Camera Mod. # Manufacturer Mega Pixel

(MP) ONIF-S

Estimated Quantity

IME329-1IS PELCO 3 YES 111

IM10C10 PELCO 1.3 No 10

IMP321-1RS PELCO 3 YES 95

IMP221-1IS PELCO 2 YES 13

WV-NP244 Panasonic Not Aval Not Aval 21 WV-SP305 Panasonic 1.3 Not Aval 16

ONCAM Unknown Unknown 7

IMP221-1ES PELCO 2 YES 9

IMP121-1ES PELCO 1 YES 3

IMP521-1RS PELCO 5 YES 1

WV-SP305 Panasonic 1.3 Not Aval 2

D5220 PELCO 2 YES 2

WV-NP1004 Panasonic 1.25 Not Aval 1 1M10LW10 PELCO 1.2 No 6

IMP1110-1 PELCO 1 YES 27

IME119 PELCO 1 YES 15

IMP221-1RS PELCO 2 YES 4

IMP121-1IS PELCO 1 YES 4

IMP121A-1IS PELCO 1 YES 1

IMM12036 PELCO 12 YES 18

IMM12027 PELCO 12 YES 11

IMM12018 PELCO 12 YES 24

IMP331-1IS PELCO 3 YES 1

Model numbers provided by the VA Minimum Criteria 2 MP, ONIV-S capable Camera not in minimum criteria 113 Total cameras on site 402 `% of cameras not in compliance 28.11%

NOTE THAT NORTH BEND CURRENTLY HAS A RECENT SYSTEM AND BROOKINGS IS EXPECTED THAT A NEW

SYSTEM IS IMPLEMENTED. AS SUCH ROSEBURG IS ONLY SHOWN IN THIS DELIVERABLE.

Unknown

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

E1.02 - NORTH

E1.01 - SOUTH

E1.02 - NORTH

E1.01 - SOUTH

PARKING

LOT #4

PARKING

LOT #12

PARKING

LOT #13

PARKING

LOT #14

PARKING

LOT #15

PARKING

LOT #1

PARKING

LOT #3

PARKING

LOT #2

BLDG

BLDG

BLDG

BLDG

BLDG

9 7

BLDG

BLDG

BLDG

T6

BLDG

T7

BLDG

T8

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

T20

BLDG

BLDG

BLDG

T15

BLDG

T19

BLDG

PARKING

LOT #16

BLDG

BLDG

BLDG

BLDG

BLDG

12 13

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

E-RB-101

ROSEBURG - POLE CAMERA

LOCATIONS - NORTH

DA2.5

AAA2.2

E1.01 - SOUTH

DA2.5

AAA2.2

NORTH

KEYPLAN

NORTH

SCALE:1 CAMERA SITE PLAN - NORTH

1" = 50'-0"

PROPOSED LICENSE PLATE READER LOCATION. CONNECT TO NEAREST TR.

RUN SHALL BE EXPECTED TO BE DIRECTIONAL BORING. CONTRACTOR SHALL

INCLUDE UTILITIES LOCATION IN BID. (FUTURE WORK)

ROSEBURG NORTH SITE PLAN CAMERAS INFORMATION

CAMERA ID CAMERA LOCATION MODEL NAME AND TYPE

REQUIRED BY

PSRDM

CA-RSP-001 PARKING LOT 3 LEFT SEE NOTE 1 YES

CA-RSP-002 PARKING LOT 3 RIGHT SEE NOTE 1 YES

CA-RSP-003 PARKING LOT 4 SEE NOTE 1 YES

CA-RSP-004 PARKING LOT 4 SEE NOTE 1 YES

CA-RSP-005 PARKING LOT 4 SEE NOTE 1 YES

CA-RSP-006 PARKING LOT 4 SEE NOTE 1 YES

CA-RSP-007 PARKING LOT 4 SEE NOTE 1 YES

CA-RSP-008 BLDG 13 PARKING LOT SEE NOTE 1 YES

CA-RSP-009 BLDG T6 SEE NOTE 1 YES

CA-RSP-010 BLDG 62 PARKNG LOT SEE NOTE 1 YES

CA-RSP-011 BLD2 62 PARKING LOT SEE NOTE 1 YES

CA-RSP-012 PARKING LOT 15 SEE NOTE 1 YES

CA-RSP-013 PARKING LOT 14 SEE NOTE 1 YES

CA-RSP-014 PAKRING LOT 14 SEE NOTE 1 YES

CA-RSP-015 PARKING LOT 13 SEE NOTE 1 YES

CA-RSP-016 SITE GATE SEE NOTE 1 YES

NOTE 1 - REFER TO THE ROSEBURG CAMERA CAPABILITY SUMMARY TABLE

FOR ADDITIONAL DETAILS. GENERAL CONTRACTOR SHALL INCLUDE IN BID TO

IDENTIFY AND LABELS ALL CAMERAS.

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

E1.02 - NORTH

E1.01 - SOUTH

E1.02 - NORTH

E1.01 - SOUTH

PROPOSED LICENSE PLATE READER LOCATION.

CONNECT TO NEAREST TR. RUN SHALL BE

EXPECTED TO BE DIRECTIONAL BORING.

CONTRACTOR SHALL INCLUDE UTILITIES

LOCATION IN BID. (FUTURE WORK)

PROPOSED LICENSE PLATE READER LOCATION.

CONNECT TO NEAREST TR. RUN SHALL BE

EXPECTED TO BE DIRECTIONAL BORING.

CONTRACTOR SHALL INCLUDE UTILITIES

LOCATION IN BID. (FUTURE WORK)

PARKING

LOT #10

PARKING

LOT #9

PARKING

LOT #7

PARKING

LOT #8

PARKING

LOT #11

PARKING

LOT #11

PARKING

LOT #6

PARKING

LOT #5

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

23 24

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

E-RB-102

ROSEBURG - POLE CAMERA

LOCATIONS - SOUTH

NORTH

DA2.5

AAA2.2

DA2.5

AAA2.2

SOUTH

KEYPLAN

SCALE:1 CAMERA SITE PLAN - SOUTH

1" = 50'-0"

ROSEBURG SOUTH SITE PLAN CAMERAS INFORMATION

CAMERA ID CAMERA LOCATION MODEL NAME AND TYPE

REQUIRED BY

PSRDM

CA-RSP-017 PARKING LOT 6 SEE NOTE 1 YES

CA-RSP-018 PARKING LOT 11 NORTH SEE NOTE 1 YES

CA-RSP-019 PARKING LOT 11 SOUTH SEE NOTE 1 YES

CA-RSP-020 PARKING LOT 8 SEE NOTE 1 YES

CA-RSP-021 PARKING LOT 8 SEE NOTE 1 YES

CA-RSP-022 PARKING LOT 7 SEE NOTE 1 YES

CA-RSP-023 PARKING LOT 7 SEE NOTE 1 YES

CA-RSP-024 PARKING LOT 7 SEE NOTE 1 YES

CA-RSP-025 PARKING LOT 9 SEE NOTE 1 YES

CA-RSP-026 PARKING LOT 9 SEE NOTE 1 YES

CA-RSP-027 BLDG 15 PARKING LOT SEE NOTE 1 YES

CA-RSP-028 PARKING LOT 10 SEE NOTE 1 YES

CA-RSP-029 PARKING LOT 10 SEE NOTE 1 YES

CA-RSP-030 SITE GATE SEE NOTE 1 YES

CA-RSP-031 SITE GATE SEE NOTE 1 YES

NOTE 1 - REFER TO THE ROSEBURG CAMERA CAPABILITY SUMMARY TABLE

FOR ADDITIONAL DETAILS. GENERAL CONTRACTOR SHALL INCLUDE IN BID TO

IDENTIFY AND LABELS ALL CAMERAS.

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

E-RB-201

FIBER

ROOM

IT

UTIL.

STAIRS

STRESS

TEST

TLT.

CLEAN

UTILITY

MALE

TLT.

FEMALE

TLT. EXAM

CORRIDOR

WAIT

BONE

DENSITY

ULTRA

SOUND

DRESS

ECHO

READING

ECHO

HSK

STOR.

HSK WAIT

ELECT.

UTIL.

STAIRS

ELEVATOR

HALL

VESTIBULE

POLICE

TLT.

OFFICE

TELECOM

MDF

SWITCH

ROOM

STORAGE

CORR.

OCC

THERAPY

P.T.

WAITING

MORGUE

STOR.

STOR

TLT.

PT/GYM

OFFICEPHYSICAL

THERAPY

ELEC.

ELEC.

OFFICE

FILE

STORAGE

FILE

STORAGE

FEMALE

LOCKER

PT/WORK

STORAGE

ADA

TLT.

EXAM

MECH

SHOWER

CT

ROOM

POWER

& STOR

CT

CONTROL

GE R/F

#1

LAUNDRY

CORRIDOR

PHONE/

DATA

FEMALE

LOCKER

CORRIDOR

FILE

STORAGE

OFFICE

FLIE

STORAGE

FILE

STORAGE STORAGE

ELEVATOR

LAUNDRY

CHUTE

DOCK

LAUNDRY

CHUTE

DOCK

E1

E2 E3

E 4

E

E5

E7

E8

E9

E10

E

E

E

P17 P18

E19

E20

E21

E35

E39

E

VIEWING STATION

E-RB-201

MATCHLINE

MATCHLINE

E-RB-401

E-RB-401

IT

UTIL.

15 E

16 E

POLICE

TLT.

OFFICE

6 EVA PC

KVM SWITCH

BROOKINGS AND

NORTH BEND VIEW

MONITOR

ROSEBURG

VIEW

MONITOR

ROSEBURG

LOCAL MONITOR

BROOKINGS AND

NORTH BEND REMOTE

LOCAL MONITORS

ROSEBURG

NETWORK

PC

VA BROOKINGS AND

NORTH BEND PC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

E-RB-201

ROSEBURG BLDG 1 - FL1 - FLOOR

PLAN 1

GENERAL NOTES

A. THE SCOPE OF WORK CONSIST OF THE INSTALLATION OF NEW

CAMERAS WITHIN THE FACILITY TO BE PROPERLY WIRED BACK

TO THE DATA RACK INSIDE TELECOM ROOM.

B. CONTRACTOR SHALL PROVIDE WIRING, CONDUIT AND TESTING

FOR DISTURBED SYSTEM INTENDED TO REMAIN.

C. CONTRACTOR SHALL COORDINATE WITH VA POLICE FOR

ACCESS TO MAIN SECURITY CAMERA SERVER.

D. CAMERA LOCATIONS ARE SHOWN FOR DIAGRAMMATICAL

PURPOSES ONLY. CONTRACTOR SHALL VERIFY AND

COORDINATE ACTUAL LOCATION FOR INSTALLATION OF

CAMERAS.

E. CONTRACTOR SHALL INCLUDE IN BID THE WORK TO CAREFULLY

REMOVE AND REINSTALL ANY CEILING TILES AND CEILING

EQUIPMENT THAT ARE REQUIRED TO ALLOW THE ROUTING OF

NEW CABLES. ANY DAMAGED CEILING TILE OR EQUIPMENT

SHALL BE REPLACED.

F. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING THE

LABELING OF THE CABLE PLANT ON BOTH ENDS. LABELING

REQUIREMENTS SHALL COMPLY WITH TIA-606 STANDARDS.

KEY PLAN NTS NORTH

AREA 1

AREA 3

AREA 2

KEY PLAN

AREA 4

AREA 5

AREA 6

SCALE: 1/8" = 1'-0"

B01 FIRST FLOOR SECURITY PARTIAL FLOOR PLAN1

SCALE: 1/4" = 1'-0"

SERVER ROOM A109 ENLARGED PLAN2

# KEYNOTES

1. EXISTING SATELLITE NETWORK HUBS SUPPORTING CAMERAS

THROUGHOUT THE SITE.

2. VIEWING STATION SETUP CONSIST OF TWO WALL MOUNTED

MONITORS CONNECTED TO LOCAL COMPUTERS WITH

KEYBOARD AND MOUSE. SYSTEM SHALL HAVE HIGH LEVEL

ACCESSIBILITY SHOWING CAMERA COVERAGE ON ONE SCREEN

AND ON THE OTHER CAMERA DATA AND INFORMATION.

BUILDING 1 AREA 1 FIRST FLOOR CAMERAS INFORMATION

CAMERA ID CAMERA LOCATION MODEL NAME AND TYPE

REQUIRED BY

PSRDM

CA-1F1-001 EXTERIOR WALL SEE NOTE 1 YES

CA-1F1-002 CORRIDOR E102 SEE NOTE 1 YES

CA-1F1-003 CORRIDOR E102 SEE NOTE 1 NO

CA-1F1-004 STAIRS E103 SEE NOTE 1 NO

CA-1F1-005 EXT. IT A108 SEE NOTE 1 YES

CA-1F1-006 SB COMM C103 SEE NOTE 1 YES

CA-1F1-007 EXT. CORR E107 SEE NOTE 1 YES

CA-1F1-008 CORRIDOR. E107 SEE NOTE 1 YES

CA-1F1-009 STAIRS E106 SEE NOTE 1 YES

CA-1F1-010 TELECO MDF C103C SEE NOTE 1 YES

CA-1F1-011 ELECT E118A SEE NOTE 1 YES

CA-1F1-012 ELEVATOR SEE NOTE 1 YES

CA-1F1-013 WAITING E100 SEE NOTE 1 YES

CA-1F1-014 ULTRA SOUND A100B SEE NOTE 1 YES

CA-1F1-015 SERVER A109 SEE NOTE 1 YES

CA-1F1-016 IT A108 SEE NOTE 1 YES

CA-1F1-017 EXTERIOR EAST SEE NOTE 1 YES

CA-1F1-018 EXTERIOR VEST E100 SEE NOTE 1 YES

SCALE: 1/4" = 1'-0"

SWITCH BOARD COMMUNCATION ENLARGED PLAN3

NOTE 1 - REFER TO THE ROSEBURG CAMERA CAPABILITY SUMMARY TABLE

FOR ADDITIONAL DETAILS. GENERAL CONTRACTOR SHALL INCLUDE IN BID TO

IDENTIFY AND LABELS ALL CAMERAS.

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

DRAFTELEVATOR

HALL

VESTIBULE

MORGUE

STOR.

STOR

TLT.

ELEC.

ELEC.

OFFICE

FEMALE

LOCKER

RECEPTION

CORRIDORCORRIDOR

CORRIDOR

SHOWER

CT

ROOM

POWER

& STOR

CT

CONTROL

PAT.

HALL

GE R/F

#1

CONT. CONT.

EQUIPMENT

ADA

TLT.

ADA

TLT.

PHILLIPS

R/F #2

ADA

SHWR/TLT.

ADA

DRESS

DRESS

PATIENT

HALL

DRESS

DRESS

NUCLEAR

MEDICINE

ADA

TLT.

MECH

HOT

LAB

CHEST

X-RAY CONTROL

CLEAN

SUPPLYPATIENT

HALL

STAFF

ADA

TLT

SUPPLY

STAFF

LOUNGE

OUTPATIENT

WAITING

CHECK-IN

TECH

HUB

CORRIDOR

STAFF

HALL

RADIOLOGY

READINGOFFICEHSK

ELEC.

LAUNDRY

CORRIDOR

PHONE/

DATA

RADIOLOGY

FILES

EVS

LOBBY

PHONE/DATABOI

WASTE

ELEVATOR

STAIRS

HSK

STORAGE FEMALE

TLT.

MALE

TLT.

HAC

OFFICE OFFICE OFFICE OFFICE

OFFICE OFFICE

TRAVEL

CORRIDOR

STORAGEOFFICETLT. OFFICE

HALL

CORRIDOR HALL

TLT.

STORAGE

MECH

ROOM

SWITCH

GEAR

MED

GAS

STORAGE

WORKSHOP

EXAM

STAFF

LOUNGE

TLT.

NURSE

STATION

STAIRS

FEMALE

LOCKER

CORRIDOR

OFFICE

ELEC. ROOM VESTIBULE

EXAM

CORRIDOR

CLEAN

SUPPLY EXAM

EXAM

HALL

EXAM

STORAGE

EXAM

WAITING

PATIENT

EDUCATION

OFFICE

LAB

BLOOD

DRAW

TLT.TLT.

WAIT

AGENT

CASHIER

STORAGE

DOCK

LAUNDRY

CHUTE

BLDG 84

MRI

COFFEE

VENDER

DOCK

DOCK

LAUNDRY

CHUTE

BLDG 84

MRI

COFFEE

VENDER

DOCK

CR

KR AK

KR

E

E

E

E19

E20

E21

E22

E23

E

E

E

E27

E28

E29

E

E

E

E33

P

E39

E

P43

E83

E84

E85

E

P91

MATCHLINE MATCHLINE

MATCHLINE

MATCHLINE

E-RB-202

ROSEBURG BLDG 1 - FL1 - FLOOR

PLAN 2

GENERAL NOTES

A. THE SCOPE OF WORK CONSIST OF THE INSTALLATION OF NEW

CAMERAS WITHIN THE FACILITY TO BE PROPERLY WIRED BACK

TO THE DATA RACK INSIDE TELECOM ROOM.

B. CONTRACTOR SHALL PROVIDE WIRING, CONDUIT AND TESTING

FOR DISTURBED SYSTEM INTENDED TO REMAIN.

C. CONTRACTOR SHALL COORDINATE WITH VA POLICE FOR

ACCESS TO MAIN SECURITY CAMERA SERVER.

D. CAMERA LOCATIONS ARE SHOWN FOR DIAGRAMMATICAL

PURPOSES ONLY. CONTRACTOR SHALL VERIFY AND

COORDINATE ACTUAL LOCATION FOR INSTALLATION OF

CAMERAS.

E. CONTRACTOR SHALL INCLUDE IN BID THE WORK TO CAREFULLY

REMOVE AND REINSTALL ANY CEILING TILES AND CEILING

EQUIPMENT THAT ARE REQUIRED TO ALLOW THE ROUTING OF

NEW CABLES. ANY DAMAGED CEILING TILE OR EQUIPMENT

SHALL BE REPLACED.

F. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING THE

LABELING OF THE CABLE PLANT ON BOTH ENDS. LABELING

REQUIREMENTS SHALL COMPLY WITH TIA-606 STANDARDS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

SCALE:1 B01 FIRST FLOOR SECURITY PARTIAL FLOOR PLAN

1/8" = 1'-0"

KEY PLAN NTS NORTH

AREA 1

AREA 3

AREA 2

KEY PLAN

AREA 4

AREA 5

AREA 6

BUILDING 1 AREA 2 FIRST FLOOR CAMERAS INFORMATION

CAMERA ID CAMERA LOCATION MODEL NAME AND TYPE

REQUIRED BY

PSRDM

CA-1F1-019 CORRIDOR E121A SEE NOTE 1 YES

CA-1F1-020 EXT. CORRIDOR E121A SEE NOTE 1 YES

CA-1F1-021 EXT ELEC. E135 SEE NOTE 1 NO

CA-1F1-022 HALL E101B SEE NOTE 1 NO

CA-1F1-023 DOCK SEE NOTE 1 YES

CA-1F1-024 STAIRS E122 SEE NOTE 1 YES

CA-1F1-025 ELEVATOR SEE NOTE 1 YES

CA-1F1-026 ELEVATOR SEE NOTE 1 YES

CA-1F1-027 LOBBY E121 SEE NOTE 1 YES

CA-1F1-028 PATIENT HALL E101A SEE NOTE 1 YES

CA-1F1-029 CORRIDOR E105 SEE NOTE 1 YES

CA-1F1-030 ELEVATOR SEE NOTE 1 YES

CA-1F1-031 CORRIDOR E124 SEE NOTE 1 YES

CA-1F1-032 CORRIDOR E124 SEE NOTE 1 YES

CA-1F1-033 CORRIDOR D117 SEE NOTE 1 YES

CA-1F1-034 EXT. MECH E112 SEE NOTE 1 YES

NOTE 1 - REFER TO THE ROSEBURG CAMERA CAPABILITY SUMMARY TABLE

FOR ADDITIONAL DETAILS. GENERAL CONTRACTOR SHALL INCLUDE IN BID TO

IDENTIFY AND LABELS ALL CAMERAS.

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

FIBER

TELECOM

MDF

SWITCH

ROOM OFFICEPHYSICAL

THERAPY

OFFICE

FILE

STORAGE

FILE

STORAGE

FEMALE

LOCKER

PT/WORK

STORAGE

OFFICE

FILE

ROOM

FEMALE

LOCKER

CORRIDOR

FILE

STORAGE

OFFICE

FLIE

STORAGE

FILE

STORAGE

STORAGE

CORRIDOR

MALE

TLT.

STORAGE

MALE

LOCKERS

STORAGE

OFFICE

OFFICE OFFICE

CORRIDOR

FILE

ROOM

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE/

WAITING

OFFICE

OFFICE

STAIRS

ELEVATOR

BLDG 60

DOCK

LOADING

TUNNEL

DOCK

STORAGE BUILDING

BLDG 60

DOCK

LOADING

TUNNEL

DOCK

EMERGENCY GENERATOR

E35

E36 E37

E38

E39

E40

E42

E

P43

P44

P45

P99

P95 P96

P97

P98

MATCHLINE

MATCHLINE

MATCHLINE

MATCHLINE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

E-RB-203

ROSEBURG BLDG 1 - FL1 - FLOOR

PLAN 3

GENERAL NOTES

A. THE SCOPE OF WORK CONSIST OF THE INSTALLATION OF NEW

CAMERAS WITHIN THE FACILITY TO BE PROPERLY WIRED BACK

TO THE DATA RACK INSIDE TELECOM ROOM.

B. CONTRACTOR SHALL PROVIDE WIRING, CONDUIT AND TESTING

FOR DISTURBED SYSTEM INTENDED TO REMAIN.

C. CONTRACTOR SHALL COORDINATE WITH VA POLICE FOR

ACCESS TO MAIN SECURITY CAMERA SERVER.

D. CAMERA LOCATIONS ARE SHOWN FOR DIAGRAMMATICAL

PURPOSES ONLY. CONTRACTOR SHALL VERIFY AND

COORDINATE ACTUAL LOCATION FOR INSTALLATION OF

CAMERAS.

E. CONTRACTOR SHALL INCLUDE IN BID THE WORK TO CAREFULLY

REMOVE AND REINSTALL ANY CEILING TILES AND CEILING

EQUIPMENT THAT ARE REQUIRED TO ALLOW THE ROUTING OF

NEW CABLES. ANY DAMAGED CEILING TILE OR EQUIPMENT

SHALL BE REPLACED.

F. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING THE

LABELING OF THE CABLE PLANT ON BOTH ENDS. LABELING

REQUIREMENTS SHALL COMPLY WITH TIA-606 STANDARDS.

SCALE:1 B01 FIRST FLOOR SECURITY PARTIAL FLOOR PLAN

1/8" = 1'-0"

KEY PLAN NTS NORTH

AREA 1

AREA 3

AREA 2

KEY PLAN

AREA 4

AREA 5

AREA 6

BUILDING 1 AREA 3 FIRST FLOOR CAMERAS INFORMATION

CAMERA ID CAMERA LOCATION MODEL NAME AND TYPE

REQUIRED BY

PSRDM

CA-1F1-035 EXT. OFFICE C100J SEE NOTE 1 YES

CA-1F1-036 STORAGE C113C SEE NOTE 1 YES

CA-1F1-037 CORRIDOR E117 SEE NOTE 1 YES

CA-1F1-038 CORRIDOR E117 SEE NOTE 1 YES

CA-1F1-039 CORRIDOR E120 SEE NOTE 1 YES

CA-1F1-040 DOCK E109 SEE NOTE 1 YES

CA-1F1-041 DOCK E109 SEE NOTE 1 YES

CA-1F1-042 EXT. OFFICE C115B SEE NOTE 1 YES

CA-1F1-043 EXT. STAIRWELL SEE NOTE 1 YES

CA-1F1-044 STAIRS E111 SEE NOTE 1 YES

CA-1F1-045 ENTRANCE STAIRS E111 SEE NOTE 1 YES

CA-1F1-095 OFFICE C115A SEE NOTE 1 YES

CA-1F1-096 OFFICE C115B SEE NOTE 1 YES

CA-1F1-097 FILE RM C105C SEE NOTE 1 YES

CA-1F1-098 FILE RM C105E SEE NOTE 1 YES

CA-1F1-099 OFFICE C105B SEE NOTE 1 YES

NOTE 1 - REFER TO THE ROSEBURG CAMERA CAPABILITY SUMMARY TABLE

FOR ADDITIONAL DETAILS. GENERAL CONTRACTOR SHALL INCLUDE IN BID TO

IDENTIFY AND LABELS ALL CAMERAS.

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

TLT.

STORAGE

MECH

ROOM

SWITCH

GEAR

MED

GAS

STORAGE

WORKSHOP

EXAM

STAFF

LOUNGE

TLT.

NURSE

STATION

CORRIDOR

WAIT

GROUP

VISIT

INTERVIEW

INTERVIEW

INTERVIEW

INTERVIEW

WAIT

EXAMEXAM

EXAMEXAM

STORAGE

RN

STATION

EXAM EXAM

WAIT

ELEC. ROOM VESTIBULE

EXAM

CORRIDOR

CLEAN

SUPPLY EXAM

EXAM

HALL

EXAM

STORAGE

EXAM

WAITING

CORRIDOR

PATIENT

EDUCATION

OFFICE

LAB

BLOOD

DRAW

TLT.

ELEVATOR

(FUTURE)

CLEAN

SUPPLY

HAC MED

ROOM

SOILED

UTILITY TLT. EXAM EXAM EXAM TLT.EXAM OFFICE

WAIT

OFFICE

RECEPTION

OFFICE

POLICE

OFFICE

CORRIDOR

CORRIDOR

HALLWAY

HALLWAY

OXYGEN

STORAGE

STAFF

BREAK TLT. HOLDING

AODVESTIBULEISOLATION

EXAMEXAMEXAM

MECH/ELEC

OFFICE OFFICE OFFICE OFFICE OFFICE

AMBULANCE

ENTRANCE

CORRIDOR

TELE

FEMALE

TLT.

MALE

TLT.

VIP

DISK

STORAGE

MAIN

PUBLIC

CORRIDOR

HVAC

EQUIP./

FAN

ROOM

TLT.

TRASH

OFFICE OFFICE EXAM

EXAM

EXAM

TLT.

OFFICE

MED

ROOM

NURSE

STATION

WAIT INTERVIEW INTERVIEW INTERVIEW INTERVIEW

WORK

OFFICE

CLEAN

UTILIYSOILED

UTILITY

TLT.ELECT.

CORRIDOR

HAC

AUDIOLOGY

AUDIOLOGY

BOOTH EXAM EXAM EXAM

PROCEDURE

ROOM

TLT.

STAFF

ROOM

E170

PHARMACIST

OFFICE

OFFICE

STORAGE

EXAM

TLT.

EXAM

URGENT CARE

RN STATION

ENTRANCE

AMBULANCE

DOCK

LOADING

LOADING

DOCK

TUNNEL

URGENT CARE

RN STATION

ENTRANCE

AMBULANCE

DOCK

LOADING

LOADING

DOCK

TUNNEL

CR

KR

KR

CR

E46

E47

E

E49

E

E51

E52

E53

E54 E

E56

E

E

E59

E

E61

E62 E63

E

E65

E66

E67

E

E69

P70 P71

E

E75

P78

P80

E82

VIEWING STATION

E-RB-204

MATCHLINE MATCHLINE

AOD

ROSEBURG MONITOR

BROOKINGS AND NORTH BEND

MONITOR

KEYBOARD

PC

PC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

E-RB-204

ROSEBURG BLDG 1 - FL1 - FLOOR

PLAN 4

GENERAL NOTES

A. THE SCOPE OF WORK CONSIST OF THE INSTALLATION OF NEW

CAMERAS WITHIN THE FACILITY TO BE PROPERLY WIRED BACK

TO THE DATA RACK INSIDE TELECOM ROOM.

B. CONTRACTOR SHALL PROVIDE WIRING, CONDUIT AND TESTING

FOR DISTURBED SYSTEM INTENDED TO REMAIN.

C. CONTRACTOR SHALL COORDINATE WITH VA POLICE FOR

ACCESS TO MAIN SECURITY CAMERA SERVER.

D. CAMERA LOCATIONS ARE SHOWN FOR DIAGRAMMATICAL

PURPOSES ONLY. CONTRACTOR SHALL VERIFY AND

COORDINATE ACTUAL LOCATION FOR INSTALLATION OF

CAMERAS.

E. CONTRACTOR SHALL INCLUDE IN BID THE WORK TO CAREFULLY

REMOVE AND REINSTALL ANY CEILING TILES AND CEILING

EQUIPMENT THAT ARE REQUIRED TO ALLOW THE ROUTING OF

NEW CABLES. ANY DAMAGED CEILING TILE OR EQUIPMENT

SHALL BE REPLACED.

F. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING THE

LABELING OF THE CABLE PLANT ON BOTH ENDS. LABELING

REQUIREMENTS SHALL COMPLY WITH TIA-606 STANDARDS.

SCALE:1 B01 FIRST FLOOR SECURITY PARTIAL FLOOR PLAN

1/8" = 1'-0"

KEY PLAN NTS NORTH

AREA 1

AREA 3

AREA 2

KEY PLAN

AREA 4

AREA 5

AREA 6

# KEYNOTES

1. EXISTING SATELLITE NETWORK HUBS SUPPORTING CAMERAS

THROUGHOUT THE SITE.

2. VIEWING STATION SETUP CONSIST OF TWO WALL MOUNTED

MONITORS CONNECTED TO A LOCAL COMPUTER WITH

KEYBOARD AND MOUSE. SYSTEM SHALL HAVE LOW LEVEL

ACCESSIBILITY SHOWING CAMERA COVERAGE ON ONE SCREEN

AND ON THE OTHER CAMERA DATA AND INFORMATION.

3. FOR ADDITIONAL INFORMATION ON THE SATELLITE NETWORK

HUB CONNECTION REFER TO THE RISER DIAGRAM ON SHEET

E-500.

SCALE: 1/4" = 1'-0"

SWITCH BOARD COMMUNCATION ENLARGED PLAN2

BUILDING 1 AREA 4 FIRST FLOOR CAMERAS INFORMATION

CAMERA ID CAMERA LOCATION MODEL NAME AND TYPE

REQUIRED

BY PSRDM

CA-1F1-046 CORRIDOR E121A SEE NOTE 1 YES

CA-1F1-047 EXT. CORRIDOR E121A SEE NOTE 1 YES

CA-1F1-048 EXT ELEC. E135 SEE NOTE 1 NO

CA-1F1-049 HALL E101B SEE NOTE 1 NO

CA-1F1-050 DOCK SEE NOTE 1 YES

CA-1F1-051 STAIRS E122 SEE NOTE 1 YES

CA-1F1-052 ELEVATOR SEE NOTE 1 YES

CA-1F1-053 ELEVATOR SEE NOTE 1 YES

CA-1F1-054 LOBBY E121 SEE NOTE 1 YES

CA-1F1-055 PATIENT HALL E101A SEE NOTE 1 YES

CA-1F1-056 CORRIDOR E105 SEE NOTE 1 YES

CA-1F1-057 ELEVATOR SEE NOTE 1 YES

CA-1F1-058 CORRIDOR E124 SEE NOTE 1 YES

CA-1F1-059 CORRIDOR E124 SEE NOTE 1 YES

CA-1F1-060 CORRIDOR D117 SEE NOTE 1 YES

CA-1F1-061 EXT. MECH E112 SEE NOTE 1 YES

CA-1F1-062 EXTERIOR EAST SEE NOTE 1 YES

CA-1F1-063 EXTERIOR VEST E100 SEE NOTE 1 YES

CA-1F1-064 PAT. HALL NORTH C134 SEE NOTE 1 YES

CA-1F1-065 SECLUSION VEST. D101 SEE NOTE 1 NO

CA-1F1-066 SECLUSION VEST. D101 SEE NOTE 1 NO

CA-1F1-067 MECH RM 3122 SEE NOTE 1 YES

CA-1F1-068 MECH RM 3122 SEE NOTE 1 YES

CA-1F1-069 EXT. MECH YARD WEST SEE NOTE 1 YES

CA-1F1-070 EXT. MECH YARD EAST SEE NOTE 1 YES

CA-1F1-071 EXT. SEC VEST. D101 SEE NOTE 1 YES

NOTE 1 - REFER TO THE ROSEBURG CAMERA CAPABILITY SUMMARY TABLE

FOR ADDITIONAL DETAILS. GENERAL CONTRACTOR SHALL INCLUDE IN BID TO

IDENTIFY AND LABELS ALL CAMERAS.

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

CORRIDOR

WAIT

CORRIDOR

OFFICE

HAC

TLT.

OFFICE

SOILED

UTILITY

EXAM

CLEAN

SUPPLY

GROUP

VISIT

INTERVIEW

INTERVIEW

INTERVIEW

INTERVIEW

WORK

WAIT

RN

STATION

EXAMEXAMEXAM

CORRIDOR

MED

ROOM

ELEC

STAFF

ROOM

TLT.

TLT.

EXAM

EXAM

DR/ND.EXAMEXAMEXAMEXAM

STORAGE

RN

STATION

EXAM EXAM EXAM EXAM EXAM DR./NP

CORRIDOR

WAIT

TLT.

EXAM

MED

ROOM

VESTIBULE

EXAM

EXAM

EXAM

LAB

BLOOD

DRAW

VIP

DISK

STORAGE

MAIN

PUBLIC

CORRIDOR

INTERVIEW INTERVIEW INTERVIEW INTERVIEW

WORK

OFFICE

CLEAN

UTILIYSOILED

UTILITY

TLT.ELECT.

STAFF

ROOM

E170

PHARMACIST

OFFICE

EXAM

STORAGE

EXAM

TLT.

EXAM EXAM

EXAM

TLT.

MED

ROOM

RN

STATION

ENTRYENTRY

KR

E66

E67

E69

P71

E72

E73

E

E75

E76

E77

P78

P79

P80

P81

E82

93 P

MATCHLINE

MATCHLINE

MATCHLINE MATCHLINE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

E-RB-205

ROSEBURG BLDG 1 - FL1 - FLOOR

PLAN 5

GENERAL NOTES

A. THE SCOPE OF WORK CONSIST OF THE INSTALLATION OF NEW

CAMERAS WITHIN THE FACILITY TO BE PROPERLY WIRED BACK

TO THE DATA RACK INSIDE TELECOM ROOM.

B. CONTRACTOR SHALL PROVIDE WIRING, CONDUIT AND TESTING

FOR DISTURBED SYSTEM INTENDED TO REMAIN.

C. CONTRACTOR SHALL COORDINATE WITH VA POLICE FOR

ACCESS TO MAIN SECURITY CAMERA SERVER.

D. CAMERA LOCATIONS ARE SHOWN FOR DIAGRAMMATICAL

PURPOSES ONLY. CONTRACTOR SHALL VERIFY AND

COORDINATE ACTUAL LOCATION FOR INSTALLATION OF

CAMERAS.

E. CONTRACTOR SHALL INCLUDE IN BID THE WORK TO CAREFULLY

REMOVE AND REINSTALL ANY CEILING TILES AND CEILING

EQUIPMENT THAT ARE REQUIRED TO ALLOW THE ROUTING OF

NEW CABLES. ANY DAMAGED CEILING TILE OR EQUIPMENT

SHALL BE REPLACED.

F. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING THE

LABELING OF THE CABLE PLANT ON BOTH ENDS. LABELING

REQUIREMENTS SHALL COMPLY WITH TIA-606 STANDARDS.

SCALE:1 B01 FIRST FLOOR SECURITY PARTIAL FLOOR PLAN

1/8" = 1'-0"

KEY PLAN NTS NORTH

AREA 1

AREA 3

AREA 2

KEY PLAN

AREA 4

AREA 5

AREA 6

BUILDING 1 AREA 5 FIRST FLOOR CAMERAS INFORMATION

CAMERA ID CAMERA LOCATION MODEL NAME AND TYPE

REQUIRED BY

PSRDM

CA-1F1-072 WAIT E174 SEE NOTE 1 YES

CA-1F1-073 EXT. EXAM E176I SEE NOTE 1 YES

CA-1F1-074 WAIT E177 SEE NOTE 1 YES

CA-1F1-075 WAIT E191 SEE NOTE 1 YES

CA-1F1-076 EXTERIOR EXAM E180A SEE NOTE 1 YES

CA-1F1-077 EXTERIOR CANOPY SEE NOTE 1 YES

CA-1F1-078 CORRIDOR E180 SEE NOTE 1 YES

CA-1F1-079 CORRIDOR E176 SEE NOTE 1 YES

CA-1F1-080 CORRIDOR E176 SEE NOTE 1 YES

CA-1F1-081 CORRIDOR E180 SEE NOTE 1 YES

NOTE 1 - REFER TO THE ROSEBURG CAMERA CAPABILITY SUMMARY TABLE

FOR ADDITIONAL DETAILS. GENERAL CONTRACTOR SHALL INCLUDE IN BID TO

IDENTIFY AND LABELS ALL CAMERAS.

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

DRAFTOFFICE

OFFICE OFFICE

TRAVEL

HALL

STORAGE

WORKSHOP

STAIRS

WAIT

CORRIDOR

OFFICE

HAC

OFFICE

SOILED

UTILITYINTERVIEW

PATIENT

EDUCATION

OFFICE

LAB

BLOOD

DRAW

TLT.TLT.

EXAM

WAIT

AGENT

CASHIER

STORAGE

CORRIDOR

CORRIDOR

EXAM

EXAM

TLT.

EXAM EXAM

EXAM EXAM EXAM OFFICE

EXAM

TLT.

MED

ROOM

RN

STATION

ENTRYENTRY

KR AK

CR

KR

E69

E75

E82

E83

E84

E85 E86

E

E94

E

E

E

P91

93 P

92 P

MATCHLINE

MATCHLINE

MATCHLINE MATCHLINE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

E-RB-206

ROSEBURG BLDG 1 - FL1 - FLOOR

PLAN 6

GENERAL NOTES

A. THE SCOPE OF WORK CONSIST OF THE INSTALLATION OF NEW

CAMERAS WITHIN THE FACILITY TO BE PROPERLY WIRED BACK

TO THE DATA RACK INSIDE TELECOM ROOM.

B. CONTRACTOR SHALL PROVIDE WIRING, CONDUIT AND TESTING

FOR DISTURBED SYSTEM INTENDED TO REMAIN.

C. CONTRACTOR SHALL COORDINATE WITH VA POLICE FOR

ACCESS TO MAIN SECURITY CAMERA SERVER.

D. CAMERA LOCATIONS ARE SHOWN FOR DIAGRAMMATICAL

PURPOSES ONLY. CONTRACTOR SHALL VERIFY AND

COORDINATE ACTUAL LOCATION FOR INSTALLATION OF

CAMERAS.

E. CONTRACTOR SHALL INCLUDE IN BID THE WORK TO CAREFULLY

REMOVE AND REINSTALL ANY CEILING TILES AND CEILING

EQUIPMENT THAT ARE REQUIRED TO ALLOW THE ROUTING OF

NEW CABLES. ANY DAMAGED CEILING TILE OR EQUIPMENT

SHALL BE REPLACED.

F. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING THE

LABELING OF THE CABLE PLANT ON BOTH ENDS. LABELING

REQUIREMENTS SHALL COMPLY WITH TIA-606 STANDARDS.

SCALE:1 B01 FIRST FLOOR SECURITY PARTIAL FLOOR PLAN

1/8" = 1'-0"

KEY PLAN NTS NORTH

AREA 1

AREA 3

AREA 2

KEY PLAN

AREA 4

AREA 5

AREA 6

BUILDING 1 AREA 6 FIRST FLOOR CAMERAS INFORMATION

CAMERA ID CAMERA LOCATION MODEL NAME AND TYPE

REQUIRED BY

PSRDM

CA-1F1-082 CORRIDOR E100 SEE NOTE 1 YES

CA-1F1-083 WAIT D107 SEE NOTE 1 YES

CA-1F1-084 AGENT CASHIER D109 SEE NOTE 1 YES

CA-1F1-085 WAIT D107 SEE NOTE 1 YES

CA-1F1-086 CORRIDOR E100 SEE NOTE 1 YES

CA-1F1-087 EXT. CORR. E100 SEE NOTE 1 YES

CA-1F1-088 CORRIDOR E180 SEE NOTE 1 YES

CA-1F1-089 EXTERIOR SEE NOTE 1 YES

CA-1F1-090 EXTERIOR SEE NOTE 1 YES

CA-1F1-091 STAIRS E128E SEE NOTE 1 YES

CA-1F1-092 CORRIDOR E193 SEE NOTE 1 YES

CA-1F1-093 CORRIDOR E193 SEE NOTE 1 YES

CA-1F1-094 EXT. EXAM E193F SEE NOTE 1 YES

NOTE 1 - REFER TO THE ROSEBURG CAMERA CAPABILITY SUMMARY TABLE

FOR ADDITIONAL DETAILS. GENERAL CONTRACTOR SHALL INCLUDE IN BID TO

IDENTIFY AND LABELS ALL CAMERAS.

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

LINEN

CHUTE

STERILE

STORAGE

LAB

LAB

OFFICE

OFFICE

STAFF

LOUNGE

WORK WORK

OFFICE

STORAGE

RECEPTION

BREAKSTORAGE

LAB

X-RAY

LAB EXAM

EXAM EXAM EXAM

EXAM

HALL

WAIT MECH OFFICE

OFFICE

OFFICEOFFICE

COPY

ROOM

LAB

LAB

TOILET

OFFICE

CONSULT

VAULTWAIT

STAIRS

HOUSE

KEEPING

MALE

TOILETSTAIRS

CHASE

HOUSE

KEEPING

CHASE

CORRIDOR

FEMALE

TOILET

CLEAN

UTILITY

LAB

CORRIDOR

ELECTRICAL

ELEVATOR OFFICE

HALLWAY

PORCH

LAB LAB

MECHANICAL

ROOM

CHEMO

PHARMACY

WORK

RESIDENTS

WORK

RECEPTION

HALLWAY

OFFICE

TOILET

LAB

HALLWAY

EXAM

OFFICE LOUNGE

STERILE

STORAGE

LINEN

CHUTE

CHASE

CHASE

EE

E

E E E

E

E

E E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

4 5 6

30 9

P51

SNH-B01-001

MATCHLINE

MATCHLINE

MATCHLINE

MATCHLINE

MATCHLINE MATCHLINE

MATCHLINE MATCHLINE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

E-RB-207

ROSEBURG BLDG 1 - FL2 - FLOOR

PLAN 1

GENERAL NOTES

A. THE SCOPE OF WORK CONSIST OF THE INSTALLATION OF NEW

CAMERAS WITHIN THE FACILITY TO BE PROPERLY WIRED BACK

TO THE DATA RACK INSIDE TELECOM ROOM.

B. CONTRACTOR SHALL PROVIDE WIRING, CONDUIT AND TESTING

FOR DISTURBED SYSTEM INTENDED TO REMAIN.

C. CONTRACTOR SHALL COORDINATE WITH VA POLICE FOR

ACCESS TO MAIN SECURITY CAMERA SERVER.

D. CAMERA LOCATIONS ARE SHOWN FOR DIAGRAMMATICAL

PURPOSES ONLY. CONTRACTOR SHALL VERIFY AND

COORDINATE ACTUAL LOCATION FOR INSTALLATION OF

CAMERAS.

E. CONTRACTOR SHALL INCLUDE IN BID THE WORK TO CAREFULLY

REMOVE AND REINSTALL ANY CEILING TILES AND CEILING

EQUIPMENT THAT ARE REQUIRED TO ALLOW THE ROUTING OF

NEW CABLES. ANY DAMAGED CEILING TILE OR EQUIPMENT

SHALL BE REPLACED.

F. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING THE

LABELING OF THE CABLE PLANT ON BOTH ENDS. LABELING

REQUIREMENTS SHALL COMPLY WITH TIA-606 STANDARDS.

SCALE:1 B01 SECOND FLOOR SECURITY PARTIAL FLOOR PLAN

1/8" = 1'-0"

KEY PLAN NTS NORTH

KEY PLAN

# KEYNOTES

1. EXISTING SATELLITE NETWORK HUBS SUPPORTING THE

BUILDING AND THE SITE CAMERAS THROUGHOUT THE SITE.

2. FOR ADDITIONAL INFORMATION ON THE SATELLITE NETWORK

HUB CONNECTION REFER TO THE RISER DIAGRAM ON SHEET

E-500.

BUILDING 1 AREA 1 SECOND FLOOR CAMERAS INFORMATION

CAMERA ID CAMERA LOCATION MODEL NAME AND TYPE

REQUIRED BY

PSRDM

CA-1F2-001 CORRIDOR E201 SEE NOTE 1 YES

CA-1F2-002 RECEPTION A209 SEE NOTE 1 YES

CA-1F2-003 HALLWAY E201B SEE NOTE 1 NO

CA-1F2-004 WORK C203B SEE NOTE 1 NO

CA-1F2-005 WORK C203B SEE NOTE 1 YES

CA-1F2-006 WORK C203B SEE NOTE 1 YES

CA-1F2-007 RECEPTION C203 SEE NOTE 1 YES

CA-1F2-008 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-009 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-010 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-011 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-012 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-013 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-014 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-015 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-016 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-017 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-018 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-019 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-020 VAULT C200D SEE NOTE 1 NO

CA-1F2-021 OFFICE C200B SEE NOTE 1 NO

CA-1F2-022 WAIT C200 SEE NOTE 1 YES

CA-1F2-023 WAIT C200 SEE NOTE 1 YES

CA-1F2-024 VAULT C200D SEE NOTE 1 YES

CA-1F2-025 CORRIDOR E205 SEE NOTE 1 YES

CA-1F2-026 ELECTRICAL E205A SEE NOTE 1 YES

CA-1F2-027 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-028 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-029 HALLWAY E219 SEE NOTE 1 YES

CA-1F2-030 PHARMACY C200C SEE NOTE 1 YES

CA-1F2-051 HOUSE KEEPING A201A SEE NOTE 1 YES

AREA 1

AREA 2

AREA 3

AREA 4

NOTE 1 - REFER TO THE ROSEBURG CAMERA CAPABILITY

SUMMARY TABLE FOR ADDITIONAL DETAILS. GENERAL

CONTRACTOR SHALL INCLUDE IN BID TO IDENTIFY AND

LABELS ALL CAMERAS.

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

CR

STAIRS

HOUSE

KEEPING

OFFICE

CLOSET

OFFICE

OFFICE

OFFICE

OFFICE

CHASE

MED

SUPPLY

STORAGE

HALLWAY

OFFICE

OFFICE

STAFF

LOUNGE

STORAGE

STAFF

TOILET

I.T.

CLOSET

OFFICE OFFICE

ANTE

I.V.

PREP

CHEMO

STAFF

LOUNGE

WORK

HALLWAY

30 E

31 E

32 E

33 E 34 E 35 E

36 E

37 E

41 P

MATCHLINE

MATCHLINE

MATCHLINE

MATCHLINE

38 E

39 E

40 P

MATCHLINE MATCHLINE

MATCHLINE MATCHLINE

MATCHLINE

MATCHLINE

MATCHLINE

MATCHLINE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

Revisions: Date:

Roseburg VAMC Campus 913 NW Garden Valley Blvd, Roseburg, OR 97471

653-25-103

JAR BS

ARCHITECT/ENGINEER OF RECORDCONSULTANTS Update Security Camera System Roseburg VAMC

100% Construction Documents Submittal

03.26.2025

FULLY SPRINKLERED

KSM A&E Federal Group 2011 27th Ave. North St. Petersburg, FL 33713

MES GROUP

550 N. Reo Street, Suite 203 Tampa, FL 33609

SM&W

177 Post Street Suite 900 San Francisco, CA 94108

NOT FOR

CONSTRUCTION

E-RB-208

ROSEBURG BLDG 1 - FL2 - FLOOR

PLAN 2

GENERAL NOTES

A. THE SCOPE OF WORK CONSIST OF THE INSTALLATION OF NEW

CAMERAS WITHIN THE FACILITY TO BE PROPERLY WIRED BACK

TO THE DATA RACK INSIDE TELECOM ROOM.

B. CONTRACTOR SHALL PROVIDE WIRING, CONDUIT AND TESTING

FOR DISTURBED SYSTEM INTENDED TO REMAIN.

C. CONTRACTOR SHALL COORDINATE WITH VA POLICE FOR

ACCESS TO MAIN SECURITY CAMERA SERVER.

D. CAMERA LOCATIONS ARE SHOWN FOR DIAGRAMMATICAL

PURPOSES ONLY. CONTRACTOR SHALL VERIFY AND

COORDINATE ACTUAL LOCATION FOR INSTALLATION OF

CAMERAS.

E. CONTRACTOR SHALL INCLUDE IN BID THE WORK TO CAREFULLY

REMOVE AND REINSTALL ANY CEILING TILES AND CEILING

EQUIPMENT THAT ARE REQUIRED TO ALLOW THE ROUTING OF

NEW CABLES. ANY DAMAGED CEILING TILE OR EQUIPMENT

SHALL BE REPLACED.

F. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING THE

LABELING OF THE CABLE PLANT ON BOTH ENDS. LABELING

REQUIREMENTS SHALL COMPLY WITH TIA-606 STANDARDS.

SCALE:1 B01 SECOND FLOOR SECURITY PARTIAL FLOOR PLAN

1/8" = 1'-0" SCALE:2 B01 SECOND FLOOR SECURITY PARTIAL FLOOR PLAN

1/8" = 1'-0"

KEY PLAN NTS NORTH

BUILDING 1 AREA 2 AND 3 SECOND FLOOR CAMERAS INFORMATION

CAMERA ID CAMERA LOCATION MODEL NAME AND TYPE

REQUIRED BY

PSRDM

CA-1F2-030 WORK C203B SEE NOTE 1 YES

CA-1F2-031 WORK C203B SEE NOTE 1 YES

CA-1F2-032 WORK C203B SEE NOTE 1 NO

CA-1F2-033 WORK C203B SEE NOTE 1 NO

CA-1F2-034 HALLWAY E217 SEE NOTE 1 YES

CA-1F2-035 OFFICE C216 SEE NOTE 1 YES

CA-1F2-036 HALLWAY E217 SEE NOTE 1 YES

CA-1F2-037 HALLWAY E218 SEE NOTE 1 YES

CA-1F2-038 CORRIDOR E207 SEE NOTE 1 YES

CA-1F2-039 NURSE STATION B222 SEE NOTE 1 YES

CA-1F2-040 CORRIDOR E207 SEE NOTE 1 YES

CA-1F2-041 STAIRS E216 SEE NOTE 1 YES

KEY PLAN

AREA 1

AREA 2

AREA 3

AREA 4

NOTE 1 - REFER TO THE ROSEBURG CAMERA CAPABILITY SUMMARY TABLE

FOR ADDITIONAL DETAILS. GENERAL CONTRACTOR SHALL INCLUDE IN BID TO

IDENTIFY AND LABELS ALL CAMERAS.

Final Construction Documents

04.08.2025 12/31/2026

04/03/2025

DRAFTOR

SUPPLY

STORAGE

SOILED

RECEIVING

AND

DECONTAMINATION

DETERGENT

ROOM

CORRIDOR

MECH.

ROOM

ETO

STERILIZER

PREPARATION

ASSEMBLY

AND

STERILIZATION

STERILE

NON-STERILE

STORAGE

ETO

AERATOR

ROOF

H.A.C.

WOMEN'S

ROOF

MEN'S

LOCKERLOCKERENDOSCOPE

PROCESSING

DISINFECTION

RM.

SCOPE

STORAGE

MANUAL

WASH

EQUIPMENT

TESTING

AND

STORAGE

DETERGENT

LOCKER

CARTWASH

CORRIDOR

ELEC.

ROOM

OFFICE

CORRIDOR

WOMEN'S

MEN'S

LOCKER

ANTEROOM

OFFICE

CORRIDOR

OFFICE

ANTEROOM

HALL

RECEIVE

BREAKDOWN

H.A.C.

CONF.

ROOM/LOUNGE

CORRIDOR

ANTEROOM

CLO.

CR

CR

CR

OFFICE

P.A.C.U. STORAGE

SOILDED

UTILTIY

NURSE

STATION

TOILET TOILET RECEPTION

OFFICE

O.R. 3

STORAGE

O.R. 2 CLEAN

STORAGE

O.R 1

CHASE

HOUSE

KEEPING

ELEVATOR

CLEAN

LINEN

HOUSE

KEEPING

CORRIDOR CORRIDOR STORAGE

E224

CLEAN

HALLWAY

ANESTESIOLOGY

WORK

FEMALE

LOCKER

MALE

LOCKER

STAFF

LOUNGE

PROCEDURE

TOILET SCOPE

CLEAN

TOILET

WAIT

STAIRS

CLEAN

SUPPLY

CHASE

CHASE

CHASE

CHASE CHASE

CHASE

CHASE

CHASE

CHASE

E2

A E233A-A

B211C

CLO.

ANTEROOM

CORRIDOR

CONF. ROOM/LOUNGE

RECEIVE

BREAKDOWN

H.A.C.ANTEROOM

HALL

OFFICE OFFICE

OFFICE

CORRIDOR

ANTEROOM

LOCKER

LOCKER

MEN'S

WOMEN'S

CORRIDOR

ELEC. ROOM

CORRIDOR

CARTWASH

DETERGENT

EQUIPMENT TESTING

AND STORAGEMANUAL WASH

SCOPE

STORAGE

ENDOSCOPE PROCESSING

DISINFECTION RM.

LOCKER LOCKER

MEN'S

ROO…