This is a Statement of Work/Performance Work Statement for accredited calibration services for accelerometers used by the Naval Surface Warfare Center (NSWC), Corona Division, Measurement Science Department.
The contractor shall provide calibration and evaluation services for two accelerometer models: the 353B04 Primary Accelerometer (calibration range 5 Hz to 20 kHz using laser interferometry) and the Q353B51 Low-Frequency Transfer Standard (calibration range 0.1 Hz to 4000 Hz). The contractor must supply all labor, equipment, and materials required; perform calibration using laser interferometry where applicable; meet accreditation standards (A2LA or equivalent); provide calibration certificates and data in electronic format; and notify the Government of any out-of-tolerance conditions. The Government will furnish the accelerometers for service. The single deliverable is a Calibration Certificate and Data Package. The period of performance is 60 days from contract award. Additional details including place of performance, shipping address, inspection and acceptance criteria, and technical points of contact are marked as "To Be Determined" (TBD) and will be finalized in the final contract documents.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CDRL_A001_Calibration_Certificate_Redacted.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 /2
STATEMENT OF WORK/PERFORMANCE WORK STATEMENT
SERVICE OF ACCELEROMETERS (CALIBRATION & EVALUATION)
1. INTRODUCTION
Naval Surface Warfare Center (NSWC), Corona Division, Measurement Science Department, Code MS35, requires the evaluation calibration services for accelerometers in support of the Navy Calibration Standards Program.
2. BACKGROUND
Measurement Science Department Corona has a requirement to provide Test and Measurement Diagnostic
Equipment (TMDE) and/or associated components for the Calibration Standards Program to support the Navy
Calibration Labs with calibration standard test equipment.
The accelerometers requiring service are used as calibration standards to support vibration measurement systems and related TMDE. Timely servicing is critical to ensure continued operational readiness and prevent delays in calibration support for fleet operations. The standard is listed in 9 ICPs and is listed in the NCE. Failure to service these assets will impact calibration capabilities and mission readiness.
In order to meet the requirements, the equipment listed in the specifications is required to be repaired/serviced.
3. SCOPE
Accredited calibration services for the following accelerometers:
• Model: 353B04 (Primary Accelerometer) o Serial Number: TBD o Calibration range: 5 Hz to 20 kHz (laser interferometry)
• Model: Q353B51 (Low-Frequency Transfer Standard) o Serial Number: TBD o Calibration range: 0.1 Hz to 4000 Hz
4. APPLICABLE DOCUMENTS
N/A
5. REQUIREMENTS
The contractor shall:
• Provide all labor, equipment, and materials required
• Perform calibration using laser interferometry (as applicable)
• Ensure accreditation standards are met (A2LA or equivalent)
• Provide calibration certificates and data on disk or electronic format
• Notify the Government of any out-of-tolerance conditions
6. GOVERNMENT FURNISHED PROPERTY
6.1 Government Furnished Material
N/A
6.2 Government Furnished Equipment
Accelerometers listed in Section 3
6.3 Government Furnished Information
N/A
2 /2
7. DELIVERABLES
NUMBER NAME
A001 Calibration Certificate and Data Package
ADDITIONAL INFORMATION
A. PERIOD OF PERFORMANCE / REQUIRED DELIVERY DATES
Service must be completed 60 days after contract award
B. PLACE OF PERFORMANCE
TBD
C. SHIPPING ADDRESS
D. INSPECTION AND ACCEPTANCE
TBD
E. TECHNICAL POINT OF CONTACT