This document is a Performance Work Statement (PWS) for providing Land Mobile Radio (LMR) maintenance services to the Fort Sill Network Enterprise Center in Oklahoma. The contractor shall provide all management, tools, supplies, equipment, and labor necessary to maintain the modernized LMR system, which supports over 4,000 subscribers across a 50-mile radius. Key requirements include responding to standard and emergency maintenance calls, performing preventative maintenance, managing software patches and system monitoring, and notifying the government of any adverse conditions. The PWS outlines service level standards, security requirements, and quality control/assurance procedures. This PWS is associated with a pre-solicitation for a federal contract opportunity, SILLLMR2024, issued by the Department of the Army Materiel Command's Army Contracting Command Aberdeen Proving Ground, for modernized LMR service and support at Fort Sill, Oklahoma. No proposals are being accepted at this time.

View the file

Other files

File Type Posted
SAM.Gov RFI Narrative.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PERFORMANCE WORK STATEMENT (PWS)

FOR

FORT SILL, OKLAHOMA

MODERNIZED LAND MOBILE RADIO (LMR) SERVICE & SUPPORT

1. DESCRIPTION OF SERVICES / GENERAL INFORMATION.

1.1 Description of Services: The Contractor shall provide all management, tools, supplies, equipment, and labor necessary to continue the maintenance on Fort Sill’s modernized Land Mobile Radio (LMR) system.

1.2 General Information: The Fort Sill Network Enterprise Center has a requirement to provide Land Mobile Radio (LMR) services to 4,000 plus subscribers, over a fifty-mile radius area, with service supporting four sites. LMR networks are critical to the successful accomplishment of the emergency service mission of first responders and the integrated Homeland Security mission. The Army initiated a systemic LMR modernization program to cycle through Army installations, BDE OPORD 24-262, Army Fielding of ACE LMR Systems to CONUS Installations, and upgrade each LMR network to ensure all networks meet the National Telecommunications Information Association (NTIA) narrow-banding mandate, meet the Association of Public Safety – Communications Office Project 25 (APCO P25) interoperability standards, address security requirements, and ensure the positioning of Army installations are able to respond to emerging Homeland Security and regional disaster support.

2. SCOPE: Services include support to the Fort Sill Network Enterprise Center in the management, operations and maintenance of the modernized Land Mobile Radio (LMR) system on Fort Sill, Oklahoma. See Attachment 1 – Fort Sill Equipment List.

3. TECHNICAL REQUIREMENTS

3.1 LMR Management:

3.1.1 Contractor shall support, monitor, and maintain the Fort Sill modernized LMR system, see Attachment 1 – Fort Sill Equipment List 1. This should include labor to troubleshoot, repair, and replace defective equipment if necessary. To ensure maintenance of equipment, contractor shall schedule regular equipment and system testing and checks, verifying proper operation. This includes using calibrated test equipment for a consistent baseline, verifying all system core software revision levels and anti-virus software are installed and operating properly, performing maintenance during the time of least impact on users.

3.1.2 Contractor shall ensure system operation meets critical communications requirements. Contractor will validate system redundancy by switching cores while in operation, archive activity warehouse data and logging recorder call records to customer provided off-line storage and perform symphony console hardware inspection and disk clean-up.

3.1.3 Contractor shall provide management of patches for operating systems and applications as well as visibility and real-time monitoring and reporting into patch compliance, reduction of security and compliance risks by minimizing installation time.

Contractor shall also provide all compatibility information and product vulnerability alert resolution or mitigation information.

3.2 Preventative Maintenance and maintenance service calls:

3.2.1 Contractor shall respond to standard maintenance calls Monday through Friday, except for federal holidays during normal duty hours 0800 to 1700 (8:00am to 5:00pm).

3.2.2 Contractor shall respond to requests for standard maintenance service calls by telephone or in person within one (1) workday.

Contractor shall have the ability to perform incident management using service desk software to document, track, and manage LMR service requests until completion. Contractor shall apply all service standards as defined in the current Army IT Portfolio, and performance measurements will align with Army IT Portfolio standards. Standard maintenance service calls shall include diagnostic work, repairs, modifications, and adjustments to return the affected equipment to manufacturer's factory specified operating parameters.

3.2.3 Contractor will remotely troubleshoot the reported issue and dispatch a technician to the customer’s location to perform the corrective maintenance. If required, the technician will replace the defective equipment using spares purchased separately by the customer and arrange for the original item to be sent to a certified Harris repair facility. The corrective maintenance will be documented in a report and the customer will be informed of the status of all repairs in progress. On-Site Corrective Maintenance is performed 8x5 Monday – Friday.

3.2.4 Contractor will perform annual preventive system maintenance which includes scheduled tests, checks, and alignment on customer’s equipment to ensure the equipment meets specifications. As part of this service, the contractor will: 1.) Use calibrated test equipment for a consistent baseline, 2.) Verify all System Core software revision levels are installed and operating properly, 3.)

Verify System anti-virus software is installed and operating properly, 4.) Perform preventive maintenance during hours that will have the least amount of impact on users and the system, 5.) Share the preventive work hours schedule in advance of the maintenance window and shows the approximate outage times (if applicable), 6.) Summarize completed work in a written report, 7.) Validate system redundancy by switching cores while in operation, 8.) Archive Activity Warehouse data to customer provided off-line storage, 9.) Archive logging recorder call records to customer provided off-line storage, 10.) Perform Symphony Console hardware inspection and disk clean-up.

3.3 Outages

3.3.1 When an outage affects the operation of the trunking system, the repair, modification and adjustment applied to the trunking system operation as a whole. Contractor shall demonstrate to the Contracting Officer’s Representative (COR) that the system is operating correctly, prior to service call being closed and then provide an email summary or status report documenting all repairs and services rendered to make the system operational again to the COR within 2 days.

3.3.2 Contractor shall resolve and complete all initial troubleshooting and repairs within five (5) workdays from the time the malfunction or outage is reported. If the repairs are not completed within five (5) workdays, documentation of the failure to comply will be annotated on the Contractor’s quarterly/annual Contractor Performance Assessment Report.

3.4 Emergency Maintenance Service Calls

3.4.1 Emergency service maintenance calls shall be provided by the Contractor seven (7) days a week, twenty-four (24) hours a day, including recognized federal holidays.

3.4.2 Contractor shall provide the COR with a site lead contact information to contact in the event emergency service is required within 10 business days of the contract being awarded.

3.4.3 Contractor shall respond by telephone and/or in person to requests for emergency service maintenance calls within four (4) hours from receipt of notification of equipment outage from the following authorized individuals: Contracting Officer (KO) or COR.

3.4.4 Contractor shall complete all emergency service maintenance calls and the equipment shall be returned to manufacturer’s factory specified operating parameters.

3.4.5 Contractor shall resolve and complete all emergency service maintenance repairs within twenty-four (24) hours from receipt of emergency service maintenance call request. If the repairs are not completed within twenty-four (24) hours, documentation of the failure to comply will be annotated on the Contractor’s monthly/annual Contractor Performance Assessment Report.

3.5 Adverse Conditions Noted by the Contractor.

3.5.1 In the event the Contractor finds that a condition or malfunction exists which affects the performance or reliability of the radio equipment, whether or not it affects the Contractor's maintenance capability, Contractor shall notify the COR of this condition or malfunction within one (1) workday. The Contractor shall provide recommendations for correction or improvement. The Contractor shall submit a written statement of the findings and recommendations to the COR.

3.5.2 Contractor shall notify the COR in the event any radio equipment is submitted for repair or service and there is indication that the equipment has been abused or misused. Contractor shall submit documentation to the COR in support of suspected cases of abuse or misuse to include: a description of the damages, suspected cause, and estimated cost to repair if repair is feasible. Contractor shall not repair the radio equipment until advised to do so by the COR.

3.6 Training.

3.6.1 All Contractor personnel shall be trained and have the required certification to provide the support as defined in this SOW. The Government will only provide one-time training to the existing contractor personnel for new technology not previously identified that can be directly correlated to the tasks within the SOW. If trained Contractor personnel are replaced, Contractor shall be responsible for training the replacement employees at the Contractor’s expense before they begin work on this contract.

4. ADMINISTRATIVE REQUIREMENTS

4.1 The Fort Sill Network Enterprise Center, located at 1647 Randolph Road in Fort Sill, Oklahoma, requires regular support from 0730 to 1630 (07:30am to 04:30pm), Monday through Friday, excluding federal holidays. Contractor shall ensure appropriate support from 0730 to 1630. The KO must approve, in advance, any deviation from the standard schedule, including any additional duty hours and all overtime supporting this requirement.

4.2 Recognized Federal holidays: Contractor (other than for emergency maintenance service) shall observe the following recognized federal holidays:

New Year’s Day Labor Day Martin Luther King Jr.’s Birthday Columbus Day President’s Day Veteran’s Day Memorial Day Thanksgiving Day Juneteenth Christmas Day Independence Day

4.3 Security. This requirement will not require access to classified and controlled or sensitive information and facilities. Contractor personnel shall comply with all applicable security and safety regulations, guidance, and procedures, including local, referenced in this SOW and in effect at the work sites.

4.3.1 Access to Protected Information. Protected information means all non-public information, including, but not limited to, trade secrets or proprietary information of other Contractors, Government source selection information, Privacy Act or personally identifiable information (PII), Controlled Unclassified Information (CUI), or any other information with distribution limited by the Government. If, during the performance of this requirement, Contractor personnel obtain access by any means to protected information, they shall not disclose, publish, divulge, release, or make known, in any manner or to any extent, the information except as necessary to carry out duties under this contract. Protected information shall be given only to persons specifically granted access to this sensitive information and may not be further divulged without specific prior written approval from an authorized U.S.

Government individual. Further, contractor employees may use any non-public information for official/authorized Government purposes, and they shall not use the information for their personal gain, the gain of their employer, or the gain of anyone else.

Contractor shall notify the Contracting Officer of any potential organizational conflicts of interest created by any such access;

however, a nondisclosure agreement will not overcome an Organizational Conflict of Interest (OCI) as defined in FAR Subpart 9.5.

Moreover, the Trade Secrets Act prohibits releasing proprietary information without the owner’s consent. Accordingly, all Government Contractors are required to mark their proprietary information, and any time the Contractor is given inadvertent access to such marked information, the Contractor shall inform the Contracting Officer of the access.

4.3.2 Physical Security: Contractor shall safeguard all Government equipment, information and property provided for Contractor use.

4.4 Contractor Identification Requirements. In accordance with FAR 37.114(c), all contractor personnel attending meetings, answering Government telephones, and working in other situations where their contractor status is not obvious are required to identify themselves as such to avoid being mistaken for Government officials. Contractors performing work at Government workplaces shall provide their employees with an easily readable identification (ID) badge indicating the employee’s name, the contractor’s name, the functional area of assignment, and a recent color photograph of the employee. Contractors shall require their employees to wear the Contractor ID badges visibly along with the Government issued CAC card and/or special access badges when performing work at Government workplaces. Contractor personnel shall also ensure that all e-mails, documents, or reports they produce are suitably marked as Contractor products and/or that Contractor participation is appropriately disclosed. All signature blocks on e-mails shall indicate that the sender is a Contractor employee and include the Contractor's company name.

4.4.1 Contractor personnel who are retired military shall not use their retired military rank/titles while working in an official role as a Government contractor on this contract.

4.5 Quality Control & Quality Assurance

4.5.1 Quality Control (QC): Contractor shall develop, implement, and maintain an effective Quality Control System that includes a written Quality Control Program (QCP). The QCP shall implement standardized procedures/methodology for monitoring and documenting contract performance to ensure all contract requirements are met.

4.5.2 Quality Assurance (QA): The Government will evaluate the Contractor’s performance under this contract IAW the Quality Assurance Surveillance Plan (QASP). This plan is a Government-only document primarily focused on what the Government must do to assure that the Contractor has performed IAW the requirements of the contract. The Government has the right to conduct inspections and performance evaluation at any time. If any aspect of the performance is not in conformance with the requirements of this contract, the Government has the right to issue to the Contractor a Nonconformance Report (NCR).

4.5.3 A Nonconformance Report (NCR) is a letter to a Contractor that identifies nonconformance of contract requirement or identifies business system deficiencies and requests Contractor corrective action with the purpose to both correct the immediate nonconformance/deficiency, and to prevent recurrence. Nothing in the NCR changes any terms or conditions of the contract, or waives any rights the Government has under the contract or in law.

4.5.3.1 An NCR is neither a contract action nor a contract remedy, but it can be a precursor to one (though not required). It is also not a punitive action (though multiple uncorrected problems or ineffective corrective action could lead to contract remedies). It is a tool and process used to document failure(s) to meet contract requirements and to work with Contractors to resolve performance issues, with the goal to prevent the need for contractual remedy. It is also a tool to provide the Contractor an opportunity to correct or replace nonconforming work when it can be accomplished within the delivery schedule.

4.5.4 Corrective Action Plan (CAP) Requirements. Contractor shall provide a CAP in response to an NCR within 10 business days of receipt or as instructed in the NCR. The CAP shall include:

• Actions planned or taken to correct the specific nonconformance

• Root cause analysis of the nonconformance

• Corrective action planned or taken to eliminate the root cause(s) and prevent recurrence of the nonconformance, to include addressing people, process, and/or tools as necessary

• Determination of whether other processes/products/services/work are affected by the root cause(s), including product/service/work already delivered to the Government

• Corrective action milestones and target date(s) for implementation.

4.6 Property and Material

4.6.1 Government Furnished Property (GFP). There will be no Government Furnished Property (GFP) under this contract.

4.6.1.1 Safeguarding Government Property. Contractor shall safeguard all Government property as defined in the DFARS, FAR and applicable regulations. The Government retains title to all Government-furnished property until properly disposed of, as authorized by law or regulation. The Contractor shall not use any Government property for any purpose other than in the performance of this contract.

4.7 Contracting Officer’s Representative (COR). KO will provide a COR Designation Letter for this Contract upon award. The Contractor shall acknowledge the COR Designation Letter in writing and return to the KO within five (5) business days of receipt.

5.0 Acronyms & Definitions

5.1 Acronyms.

Acronym Definitions AR Army Regulation CAC Common Access Card CAP Corrective Action Plan CO/KO Contracting Officer COMSEC Communications Security CONUS Continental United States DA Department of the Army DA PAM Department of the Army Pamphlet DoD Department of Defense DODD Department of Defense Directive DODI Department of Defense Instruction

DOIM Directorate of Information Management FAR Federal Acquisition Regulation IA Information Assurance IAW In-Accordance-With IM/IT Information Management/Information Technology INFOSEC Information Security IT Information Technology IT/IA Information Technology/Information Assurance LAN Local Area Network MAC Moves, Adds, and Changes NIPRNET Non-Secure Internet Protocol Router Network NCR Nonconformance Report OPM Office of Personnel Management OU Organizational Unit PM/TD Project Manager/Technical Director POC Point of Contact QA Quality Assurance QAE Quality Assurance Evaluator QASP Quality Assurance Surveillance Plan QC Quality Control QCP Quality Control Plan SA/NM Systems Administrator/Network Manager SIPRNET Secret Internet Protocol Router Network SOP Standing Operating Procedures SOW Statement of Work TB Technical Bulletins TM Technical Manuals TS Top Secret TT Trouble Tickets USC United States Code VPN Virtual Private Network WAN Wide Area Network

5.2 Definitions.

CONTRACTOR: A supplier or vendor having a contract to provide specific supplies or service to the government. The term used in this contract refers to the prime.

CONTRACTING OFFICER: A person with authority to enter into, administer, and or terminate contracts, and make related determinations and findings on behalf of the government. Note: The only individual who can legally bind the government.

CONTRACTING OFFICER'S REPRESENTATIVE (COR): An employee of the U.S. Government appointed by the contracting officer to administer the contract. Such appointment shall be in writing and shall state the scope of authority and limitations. This individual has authority to provide technical direction to the Contractor as long as that direction is within the scope of the contract, does not constitute a change, and has no funding implications. This individual does NOT have authority to change the terms and conditions of the contract.

PHYSICAL SECURITY: Actions that prevent the loss or damage of Government property.

QUALITY ASSURANCE: The government procedures to verify that services being performed by the Contractor are performed according to acceptable standards.

QUALITY CONTROL: All necessary measures taken by the Contractor to assure that the quality of an end product or service shall meet contract requirements.

SUBCONTRACTOR: One that enters into a contract with a prime contractor. The Government does not have privity of contract with the subcontractor.

WORK DAY: The number of hours per day the Contractor provides services in accordance with the contract.

WORK WEEK: Is defined as Monday through Friday, unless specified otherwise.

Fort Sill Equipment List for Maintenance

ATTACHMENT 1 – FORT SILL EQUIPMENT LIST

Part # Description Qty

VIDA Connect

NS-PNSW SERVER, DELL R640, CONNECT 1

NS-CA5G CABINET,NSS,42 RU,120V 1

NS-ZM2F POWER KIT,SR10A.4,VIDA CONNECT,110VAC 1

NS-DW1U DRAWINGS,VIDA CONNECT/ESSENTIALS 1

VS-CR70 ROUTER,ISR4321 AX APP &SEC LIC 1

VS-MN3J KIT, CISCO 4321 ROUTER, NSC MTG 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

VS-CU8A MODULE,NIM 8PORT LAYER2 GE 1

VS-CR3C ROUTER,APP,C921-4P 1

NS-PNSX SERVER, DELL R440, VMT 2

MANS-NCU3D Kit,1RU Monitor,Key Board,Mouse,KVM 2

NS-PNSW SERVER, DELL R640, CONNECT 1

NS-CA5G CABINET,NSS,42 RU,120V 1

NS-ZM2F POWER KIT,SR10A.4,VIDA CONNECT,110VAC 1

VS-CR70 ROUTER,ISR4321 AX APP &SEC LIC 1

VS-MN3J KIT, CISCO 4321 ROUTER, NSC MTG 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

VS-CU8A MODULE,NIM 8PORT LAYER2 GE 1

VS-CR3C ROUTER,APP,C921-4P 1

VS-CR3G FIREWALL, FPR1010 2

VS-CU7Z MODULE,NIM 4PORT LAYER2 GE 2

VS-CR92 SWITCH,CATALYST 3650 24P IP 2

SMT

NS-DF3H PC,SYSTEM MANAGEMENT TERMINAL 1

A30-1890-001 MONITOR, 21.5 INCH LED, 16:9 ASPECT 1

Playback Stations

NS-DF3H PC,SYSTEM MANAGEMENT TERMINAL 2

A30-1890-001 MONITOR, 21.5 INCH LED, 16:9 ASPECT 2

SMT Network Equipment

VS-CR1G ROUTER,ISR4221-SEC/K9 1

VS-MN3T KIT, CISCO 4221 ROUTER, SITE MTG 1

VS-CU5K CISCO MODULE,LX/H SINGLE/MULTI-MODE,FIBR 1

VSCU3H SWITCH,CISCO 2960 PLUS 1

VSMA6N KIT,MTG HDWR,CISCO 2960 MASTR III/V CAB 1

Console Range Control

VS-MN3T KIT, CISCO 4221 ROUTER, SITE MTG 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

VS-CU7Z MODULE,NIM 4PORT LAYER2 GE 1

VS-CU9A SWITCH,SMARTNET,C1000FE-24T-4G-L 1

UD-ZM1E CONSOLE,BUNDLE,PREMIER,WIN10 2

UD-AB2K CABLE, ETHERNET, ABR, 45CM 2

UD-AB1A SPEAKER, NANO, SYMPHONY 4

UD-CU8R MONITOR, 22IN CLASS, TOUCHSCREEN, HD 2

UD-AB1K CABLE,DISPLAYPORT TO DVI-D,10FT 2

UD-AB1F MOUSE, OPTICAL, USB, SCROLL WHEEL 2

UD-AB1G KEYBOARD, 104 KEY, USB 2

UD-AB1D SINGLE FOOTSWITCH, USB, SYMPHONY 2

UD-AB1M DESK MIC, DB9 2

UD-AB1B JACK BOX, 6 WIRE 2

CM-022218-3006WJ Adapter,6 Wire Jackbox to Headset 2

A30-1116-001 USB 3.0 TO GIGABIT ETHERNET ADAPTER BLAC 2

2C-CM22218-0305 HEADSET,OVER-THE HEAD SOLID BOOM 2

Console DES Bldg 2025

VS-MN3T KIT, CISCO 4221 ROUTER, SITE MTG 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

VS-CU7Z MODULE,NIM 4PORT LAYER2 GE 1

VS-CU9A SWITCH,SMARTNET,C1000FE-24T-4G-L 1

UD-ZM1E CONSOLE,BUNDLE,PREMIER,WIN10 1

UD-AB2K CABLE, ETHERNET, ABR, 45CM 1

UD-AB1A SPEAKER, NANO, SYMPHONY 2

UD-CU8R MONITOR, 22IN CLASS, TOUCHSCREEN, HD 1

UD-AB1K CABLE,DISPLAYPORT TO DVI-D,10FT 1

UD-AB1F MOUSE, OPTICAL, USB, SCROLL WHEEL 1

UD-AB1G KEYBOARD, 104 KEY, USB 1

UD-AB1D SINGLE FOOTSWITCH, USB, SYMPHONY 1

UD-AB1M DESK MIC, DB9 1

UD-AB1B JACK BOX, 6 WIRE 1

CM-022218-3006WJ Adapter,6 Wire Jackbox to Headset 1

A30-1116-001 USB 3.0 TO GIGABIT ETHERNET ADAPTER BLAC 1

2C-CM22218-0305 HEADSET,OVER-THE HEAD SOLID BOOM 1

UD-ZM1E CONSOLE,BUNDLE,PREMIER,WIN10 2

UD-AB2K CABLE, ETHERNET, ABR, 45CM 2

UD-AB1A SPEAKER, NANO, SYMPHONY 4

UD-CU8R MONITOR, 22IN CLASS, TOUCHSCREEN, HD 2

UD-AB1K CABLE,DISPLAYPORT TO DVI-D,10FT 2

UD-AB1F MOUSE, OPTICAL, USB, SCROLL WHEEL 2

UD-AB1G KEYBOARD, 104 KEY, USB 2

UD-AB1D SINGLE FOOTSWITCH, USB, SYMPHONY 2

UD-AB1M DESK MIC, DB9 2

UD-AB1B JACK BOX, 6 WIRE 2

CM-022218-3006WJ Adapter,6 Wire Jackbox to Headset 2

A30-1116-001 USB 3.0 TO GIGABIT ETHERNET ADAPTER BLAC 2

2C-CM22218-0305 HEADSET,OVER-THE HEAD SOLID BOOM 11

Console EOC Bldg 3382

VS-MN3T KIT, CISCO 4221 ROUTER, SITE MTG 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

VS-CU7Z MODULE,NIM 4PORT LAYER2 GE 1

VS-CU9A SWITCH,SMARTNET,C1000FE-24T-4G-L 1

UD-ZM1E CONSOLE,BUNDLE,PREMIER,WIN10 1

UD-AB2K CABLE, ETHERNET, ABR, 45CM 1

UD-AB1A SPEAKER, NANO, SYMPHONY 2

UD-CU8R MONITOR, 22IN CLASS, TOUCHSCREEN, HD 1

UD-AB1K CABLE,DISPLAYPORT TO DVI-D,10FT 1

UD-AB1F MOUSE, OPTICAL, USB, SCROLL WHEEL 1

UD-AB1G KEYBOARD, 104 KEY, USB 1

UD-AB1D SINGLE FOOTSWITCH, USB, SYMPHONY 1

UD-AB1M DESK MIC, DB9 1

UD-AB1B JACK BOX, 6 WIRE 1

CM-022218-3006WJ Adapter,6 Wire Jackbox to Headset 1

A30-1116-001 USB 3.0 TO GIGABIT ETHERNET ADAPTER BLAC 1

2C-CM22218-0305 HEADSET,OVER-THE HEAD SOLID BOOM 1

2C-CM22218-0305 HEADSET,OVER-THE HEAD SOLID BOOM 1

Console EOC Bldg 455

VS-MN3T KIT, CISCO 4221 ROUTER, SITE MTG 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

VS-CU7Z MODULE,NIM 4PORT LAYER2 GE 1

VS-CU9A SWITCH,SMARTNET,C1000FE-24T-4G-L 1

UD-ZM1E CONSOLE,BUNDLE,PREMIER,WIN10 1

UD-AB2K CABLE, ETHERNET, ABR, 45CM 1

UD-AB1A SPEAKER, NANO, SYMPHONY 2

UD-CU8R MONITOR, 22IN CLASS, TOUCHSCREEN, HD 1

UD-AB1K CABLE,DISPLAYPORT TO DVI-D,10FT 1

UD-AB1F MOUSE, OPTICAL, USB, SCROLL WHEEL 1

UD-AB1G KEYBOARD, 104 KEY, USB 1

UD-AB1D SINGLE FOOTSWITCH, USB, SYMPHONY 1

UD-AB1M DESK MIC, DB9 1

UD-AB1B JACK BOX, 6 WIRE 1

CM-022218-3006WJ Adapter,6 Wire Jackbox to Headset 1

A30-1116-001 USB 3.0 TO GIGABIT ETHERNET ADAPTER BLAC 1

Console Fire Station 1

VS-MN3T KIT, CISCO 4221 ROUTER, SITE MTG 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

VS-CU7Z MODULE,NIM 4PORT LAYER2 GE 1

VS-CU9A SWITCH,SMARTNET,C1000FE-24T-4G-L 1

UD-ZM1E CONSOLE,BUNDLE,PREMIER,WIN10 1

UD-AB2K CABLE, ETHERNET, ABR, 45CM 1

UD-AB1A SPEAKER, NANO, SYMPHONY 2

UD-CU8R MONITOR, 22IN CLASS, TOUCHSCREEN, HD 1

UD-AB1K CABLE,DISPLAYPORT TO DVI-D,10FT 1

UD-AB1F MOUSE, OPTICAL, USB, SCROLL WHEEL 1

UD-AB1G KEYBOARD, 104 KEY, USB 1

UD-AB1D SINGLE FOOTSWITCH, USB, SYMPHONY 1

UD-AB1M DESK MIC, DB9 1

UD-AB1B JACK BOX, 6 WIRE 1

CM-022218-3006WJ Adapter,6 Wire Jackbox to Headset 1

A30-1116-001 USB 3.0 TO GIGABIT ETHERNET ADAPTER BLAC 1

2C-CM22218-0305 HEADSET,OVER-THE HEAD SOLID BOOM 4

Exacom VLR

Exacom VLR HSX-601 HindSight 300/600 series VLR 1 Exacom VLR HS-LX-BU6 HindSight 300/600 series Storage Backup 1 Exacom VLR HS-Serial Serial Card 1 Exacom VLR HS-Q-Nic Quad NIC Card 1

RF Site Bald Ridge

MASA-SVP25 Site Interf ace Equipment,P25T MASTR V 1 SA-CA3P Cabinet,86 in,Black,w/32"x35" Pallet 1

SAMD8N SITE MOBILE DATA, VIDA EDGE 1

SAMD8F POWER SUPPLY, AC, VIDA EDGE 1

MASA-NCL7D Kit,Cable,Ethernet,5f t 1 MASA-NMD6G Oscillator,10MHz Ref ,120/230VAC,6 Port 2

VSVS01 VS PROD GRP, CONFIGURED MODEL NUMBER 1

VS-CR1G ROUTER,ISR4221-SEC/K9 1

VS-MN3T KIT, CISCO 4221 ROUTER, SITE MTG 1

VS-CU9A SWITCH,SMARTNET,C1000FE-24T-4G-L 4

VS-CU7Z MODULE,NIM 4PORT LAYER2 GE 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

SASG9N Feature,P25 Multisite Support 1

SAMD8E SITE MANAGER, VIDA EDGE 1

SAMD8G CONTROLLER, DIGITAL I/O 1

SAMD8K MODULE, DIGITAL IN (8) & OUT SOURCE (8) 1

SAMD8L MODULE, ANALOG INPUT (8) 1

MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3F Power Supply Shelf ,1st Pos,Cab Rack 1

SV-CA5J CABLE,DC POWER,48 IN 2

SV-DW1B Drawings,IP Simulcast/P25 Trunked 1 SV-RB3H Shelf ,14-Slot,Cabinet 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1

SV-AT1B TERMINATION,50 OHM LOAD 7

SV-CN7X Frame,Preselector,UHF,Cabinet 1 MASV-NZN8S Fan Tray,MASTR V 1

SV-ZN9K PANEL,XCONNECT,MASTR V 1

SV-CL2D Cable,Xconnect-Baseband Shelf #1 1

SV-CK4B CABLE, ETHERNET CAT5 BOOTED, VIOLET, 5FT 1

SV-CL9V Kit,Cable,Ch #1,2,9,10,17,18 MASTR V IP 1 SV-MN9S Panel,Blank,1 RU 1 MASV-NCN7R Power Strip,110VAC,2X20A Brkr,2-Cbl,6Pos 2 MASV-NCN1Z Outlet Strip,110 VAC,UL Recognized 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3E Power Supply Shelf ,2nd Pos,Cab Rack 1 SV-CL9V Kit,Cable,Ch #1,2,9,10,17,18 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CL2D Cable,Xconnect-Baseband Shelf #1 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9W Kit,Cable,Ch #3,4,11,12,19,20 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9W Kit,Cable,Ch #3,4,11,12,19,20 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1

SV-CA5J CABLE,DC POWER,48 IN 2

SV-RB3H Shelf ,14-Slot,Cabinet 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CN7X Frame,Preselector,UHF,Cabinet 1 SV-CL2E Cable,Xconnect-Baseband Shelf #2 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9X Kit,Cable,Ch #5,6,13,14,21,22 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9X Kit,Cable,Ch #5,6,13,14,21,22 MASTR V IP 1

MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CL2E Cable,Xconnect-Baseband Shelf #2 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9Y Kit,Cable,Ch #7,8,15,16,23,24 MASTR V IP 1 SV-CL9Z Cable Assembly RF,RG223,BNC/SMA,4f t 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9Y Kit,Cable,Ch #7,8,15,16,23,24 MASTR V IP 1 SV-CL9Z Cable Assembly RF,RG223,BNC/SMA,4f t 1 SV-MN3C Baffle Plate,Cabinet 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-XXXXX MASTR V,Dummy Model Number 1 MASV-NCA3P Cabinet,86 in,Black,w/32"x35" Pallet 1 SV-CL2F Cables,Xconnect-Xconnect 1 SV-CK1K Cable,Freq ref ,Cabinet to Cabinet,16 Ft 1

SAMD8V POWER OPTION, AUX AC, VIDA EDGE 1

MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3F Power Supply Shelf ,1st Pos,Cab Rack 1

SV-CA5J CABLE,DC POWER,48 IN 2

SV-DW1B Drawings,IP Simulcast/P25 Trunked 1 SV-RB3H Shelf ,14-Slot,Cabinet 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CN7X Frame,Preselector,UHF,Cabinet 1 MASV-NZN8S Fan Tray,MASTR V 1

SV-ZN9K PANEL,XCONNECT,MASTR V 1

SV-CL2D Cable,Xconnect-Baseband Shelf #1 1

SV-CK4B CABLE, ETHERNET CAT5 BOOTED, VIOLET, 5FT 1

SV-CL9V Kit,Cable,Ch #1,2,9,10,17,18 MASTR V IP 1 SV-MN9S Panel,Blank,1 RU 1 MASV-NCN7R Power Strip,110VAC,2X20A Brkr,2-Cbl,6Pos 2 MASV-NCN1Z Outlet Strip,110 VAC,UL Recognized 1 SV-CL9T Cable,Switch-Switch 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1

MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3E Power Supply Shelf ,2nd Pos,Cab Rack 1 SV-CL9V Kit,Cable,Ch #1,2,9,10,17,18 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CL2D Cable,Xconnect-Baseband Shelf #1 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9W Kit,Cable,Ch #3,4,11,12,19,20 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9W Kit,Cable,Ch #3,4,11,12,19,20 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1

SV-CA5J CABLE,DC POWER,48 IN 2

SV-RB3H Shelf ,14-Slot,Cabinet 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CN7X Frame,Preselector,UHF,Cabinet 1 SV-CL2E Cable,Xconnect-Baseband Shelf #2 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9X Kit,Cable,Ch #5,6,13,14,21,22 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9X Kit,Cable,Ch #5,6,13,14,21,22 MASTR V IP 1 MASV-NZN8R Panel,Blank Module,MASTR V 7 SV-MN3C Baffle Plate,Cabinet 1

RF Site Bldg 2970

SA-CA3P Cabinet,86 in,Black,w/32"x35" Pallet 1

SAMD8N SITE MOBILE DATA, VIDA EDGE 1

SAMD8F POWER SUPPLY, AC, VIDA EDGE 1

MASA-NCL7D Kit,Cable,Ethernet,5f t 1 MASA-NMD6G Oscillator,10MHz Ref ,120/230VAC,6 Port 1

VSVS01 VS PROD GRP, CONFIGURED MODEL NUMBER 1

VS-CR1G ROUTER,ISR4221-SEC/K9 1

VS-MN3T KIT, CISCO 4221 ROUTER, SITE MTG 1

VS-CU9A SWITCH,SMARTNET,C1000FE-24T-4G-L 2

VS-CU7Z MODULE,NIM 4PORT LAYER2 GE 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

SAMD8E SITE MANAGER, VIDA EDGE 1

SAMD8G CONTROLLER, DIGITAL I/O 1

SAMD8K MODULE, DIGITAL IN (8) & OUT SOURCE (8) 1

SAMD8L MODULE, ANALOG INPUT (8) 1

MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3F Power Supply Shelf ,1st Pos,Cab Rack 1

SV-CA5J CABLE,DC POWER,48 IN 2

SV-DW1B Drawings,IP Simulcast/P25 Trunked 1 SV-RB3H Shelf ,14-Slot,Cabinet 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1

SV-AT1B TERMINATION,50 OHM LOAD 3

SV-CN7X Frame,Preselector,UHF,Cabinet 1 MASV-NZN8S Fan Tray,MASTR V 1

SV-ZN9K PANEL,XCONNECT,MASTR V 1

SV-CL2D Cable,Xconnect-Baseband Shelf #1 1

SV-CK4B CABLE, ETHERNET CAT5 BOOTED, VIOLET, 5FT 1

SV-CL9V Kit,Cable,Ch #1,2,9,10,17,18 MASTR V IP 1 SV-MN9S Panel,Blank,1 RU 1 MASV-NCN7R Power Strip,110VAC,2X20A Brkr,2-Cbl,6Pos 2 MASV-NCN1Z Outlet Strip,110 VAC,UL Recognized 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3E Power Supply Shelf ,2nd Pos,Cab Rack 1 SV-CL9V Kit,Cable,Ch #1,2,9,10,17,18 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-SP2T Programming,Multisite 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CL2D Cable,Xconnect-Baseband Shelf #1 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9W Kit,Cable,Ch #3,4,11,12,19,20 MASTR V IP 1

MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9W Kit,Cable,Ch #3,4,11,12,19,20 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1

SV-CA5J CABLE,DC POWER,48 IN 2

SV-RB3H Shelf ,14-Slot,Cabinet 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CN7X Frame,Preselector,UHF,Cabinet 1 SV-CL2E Cable,Xconnect-Baseband Shelf #2 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9X Kit,Cable,Ch #5,6,13,14,21,22 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9X Kit,Cable,Ch #5,6,13,14,21,22 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CL2E Cable,Xconnect-Baseband Shelf #2 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9Y Kit,Cable,Ch #7,8,15,16,23,24 MASTR V IP 1 SV-CL9Z Cable Assembly RF,RG223,BNC/SMA,4f t 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9Y Kit,Cable,Ch #7,8,15,16,23,24 MASTR V IP 1 SV-CL9Z Cable Assembly RF,RG223,BNC/SMA,4f t 1

RF Site Medicine Park

SA-CA3P Cabinet,86 in,Black,w/32"x35" Pallet 1

SAMD8N SITE MOBILE DATA, VIDA EDGE 1

SAMD8F POWER SUPPLY, AC, VIDA EDGE 1

MASA-NCL7D Kit,Cable,Ethernet,5f t 1 MASA-NMD6G Oscillator,10MHz Ref ,120/230VAC,6 Port 1

VSVS01 VS PROD GRP, CONFIGURED MODEL NUMBER 1

VS-CR1G ROUTER,ISR4221-SEC/K9 1

VS-MN3T KIT, CISCO 4221 ROUTER, SITE MTG 1

VS-CU9A SWITCH,SMARTNET,C1000FE-24T-4G-L 2

VS-CU7Z MODULE,NIM 4PORT LAYER2 GE 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

SAMD8E SITE MANAGER, VIDA EDGE 1

SAMD8G CONTROLLER, DIGITAL I/O 1

SAMD8K MODULE, DIGITAL IN (8) & OUT SOURCE (8) 1

SAMD8L MODULE, ANALOG INPUT (8) 1

MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3F Power Supply Shelf ,1st Pos,Cab Rack 1

SV-CA5J CABLE,DC POWER,48 IN 2

SV-DW1B Drawings,IP Simulcast/P25 Trunked 1 SV-RB3H Shelf ,14-Slot,Cabinet 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1

SV-AT1B TERMINATION,50 OHM LOAD 4

SV-CN7X Frame,Preselector,UHF,Cabinet 1 MASV-NZN8S Fan Tray,MASTR V 1

SV-ZN9K PANEL,XCONNECT,MASTR V 1

SV-CL2D Cable,Xconnect-Baseband Shelf #1 1

SV-CK4B CABLE, ETHERNET CAT5 BOOTED, VIOLET, 5FT 1

SV-CL9V Kit,Cable,Ch #1,2,9,10,17,18 MASTR V IP 1 SV-MN9S Panel,Blank,1 RU 1 MASV-NCN7R Power Strip,110VAC,2X20A Brkr,2-Cbl,6Pos 2 MASV-NCN1Z Outlet Strip,110 VAC,UL Recognized 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3E Power Supply Shelf ,2nd Pos,Cab Rack 1 SV-CL9V Kit,Cable,Ch #1,2,9,10,17,18 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1

SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CL2D Cable,Xconnect-Baseband Shelf #1 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9W Kit,Cable,Ch #3,4,11,12,19,20 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9W Kit,Cable,Ch #3,4,11,12,19,20 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1

SV-CA5J CABLE,DC POWER,48 IN 2

SV-RB3H Shelf ,14-Slot,Cabinet 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CN7X Frame,Preselector,UHF,Cabinet 1 SV-CL2E Cable,Xconnect-Baseband Shelf #2 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9X Kit,Cable,Ch #5,6,13,14,21,22 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9X Kit,Cable,Ch #5,6,13,14,21,22 MASTR V IP 1 MASV-NZN8R Panel,Blank Module,MASTR V 7

RF Site Hill 471

SA-CA3P Cabinet,86 in,Black,w/32"x35" Pallet 1

SAMD8N SITE MOBILE DATA, VIDA EDGE 1

SAMD8F POWER SUPPLY, AC, VIDA EDGE 1

MASA-NCL7D Kit,Cable,Ethernet,5f t 1 MASA-NMD6G Oscillator,10MHz Ref ,120/230VAC,6 Port 1

VSVS01 VS PROD GRP, CONFIGURED MODEL NUMBER 1

VS-CR1G ROUTER,ISR4221-SEC/K9 1

VS-MN3T KIT, CISCO 4221 ROUTER, SITE MTG 1

VS-CU9A SWITCH,SMARTNET,C1000FE-24T-4G-L 2

VS-CU7Z MODULE,NIM 4PORT LAYER2 GE 1

VS-CU5H CISCO MODULE,SX MULTIMODE,FIBR 1

SAMD8E SITE MANAGER, VIDA EDGE 1

SAMD8G CONTROLLER, DIGITAL I/O 1

SAMD8K MODULE, DIGITAL IN (8) & OUT SOURCE (8) 1

SAMD8L MODULE, ANALOG INPUT (8) 1

MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3F Power Supply Shelf ,1st Pos,Cab Rack 1

SV-CA5J CABLE,DC POWER,48 IN 2

SV-DW1B Drawings,IP Simulcast/P25 Trunked 1 SV-RB3H Shelf ,14-Slot,Cabinet 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1

SV-AT1B TERMINATION,50 OHM LOAD 4

SV-CN7X Frame,Preselector,UHF,Cabinet 1 MASV-NZN8S Fan Tray,MASTR V 1

SV-ZN9K PANEL,XCONNECT,MASTR V 1

SV-CL2D Cable,Xconnect-Baseband Shelf #1 1

SV-CK4B CABLE, ETHERNET CAT5 BOOTED, VIOLET, 5FT 1

SV-CL9V Kit,Cable,Ch #1,2,9,10,17,18 MASTR V IP 1 SV-MN9S Panel,Blank,1 RU 1 MASV-NCN7R Power Strip,110VAC,2X20A Brkr,2-Cbl,6Pos 2 MASV-NCN1Z Outlet Strip,110 VAC,UL Recognized 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3E Power Supply Shelf ,2nd Pos,Cab Rack 1 SV-CL9V Kit,Cable,Ch #1,2,9,10,17,18 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CL2D Cable,Xconnect-Baseband Shelf #1 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9W Kit,Cable,Ch #3,4,11,12,19,20 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9W Kit,Cable,Ch #3,4,11,12,19,20 MASTR V IP 1

MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1

SV-CA5J CABLE,DC POWER,48 IN 2

SV-RB3H Shelf ,14-Slot,Cabinet 1 SV-PM1C Processor,Baseband Module,MASTR V 1 SV-CL2N Cable Assembly RF,RG223,BNC/SMA,5f t 1 SV-CN7X Frame,Preselector,UHF,Cabinet 1 SV-CL2E Cable,Xconnect-Baseband Shelf #2 1

SV-CK4A CABLE, ETHERNET CAT5 BOOTED, VIOLET, 4FT 1

SV-CL9X Kit,Cable,Ch #5,6,13,14,21,22 MASTR V IP 1 MASV-NRF5F Preselector,380-400MHz,MASTR V 1 MASV-NTXMV Station,MASTR V,P25T,380-400 MHz 1 SV-AW5N Power Amplifier,Linear,380-400MHz 1 SV-RB3K Busbar,HPA/PS,MASTR V 1 MASV-NPS2P Power Supply,110-240V,AC,MASTR V 1 SV-RB3D Power Supply Shelf ,Cab Rack 1 SV-CL9X Kit,Cable,Ch #5,6,13,14,21,22 MASTR V IP 1 MASV-NZN8R Panel,Blank Module,MASTR V 7

IO Gateways (2 each)

VS-CU9J KIT, PATHWAY ANALOG GATEWAY 6

VS-CU9L KIT, RACK MOUNT, PATHWAY DUAL UNIT 3

VS-PS3W POWER SUPPLY,AC, PATHWAY 6

VS-CU9J KIT, PATHWAY ANALOG GATEWAY 6

VS-CU9L KIT, RACK MOUNT, PATHWAY DUAL UNIT 3

VS-PS3W POWER SUPPLY,AC, PATHWAY 6

DVRS

Catalyst ICE, DVRS CABIH3-V Catalyst ICE DVRS Chassis 2 Catalyst ICE, DVRS CAAZ45 Catalyst ICE Semi Hardened Laptop 2

Programming / Keying Laptops

14021-1200-01 LAPTOP,PROGRAMMING&REMOTE KVM(P25) 2

END

ATTACHMENT 2 – PERFORMANCE REQUIREMENTS SUMMARY

Required Service

Reference Paragraph Standard Acceptable Quality

Level (AQL) Method of

Surveillance

Incentives / Disincentives for Meeting or Not

Meeting Performance

Standards

Maintenance Service Calls

3.2.2

Contractor shall respond to requests for standard maintenance service calls by telephone or in person within one (1) workday.

Contractor responds to all standard maintenance service calls within one (1) workday 100% of the time.

Periodic review of incident management service desk software tickets on a monthly basis

Positive and negative performance will be documented in monthly COR reports and past performance reports.

Outage Resolution

3.3.2

Contractor shall resolve and complete all initial troubleshooting and repairs within five (5) workdays from the time the malfunction or outage is reported.

Outages are resolved within five (5) workdays 100% of the time.

Periodic review of incident management service desk software tickets on a monthly basis

Positive and negative performance will be documented in monthly

Emergency

Service Calls

3.4.1

Contractor shall respond by telephone and/or in person to requests for emergency service maintenance calls within four (4) hours from receipt of notification of equipment outage

Contractor responds to all emergency maintenance service calls within one (1) workday 100% of the time.

Periodic review of incident management service desk software tickets on a monthly basis

Positive and negative performance will be documented in monthly

Emergency

Call Resolution

3.4.5

Contractor shall resolve and complete all emergency service maintenance repairs within twenty-four (24) hours from receipt of emergency service maintenance call request

Outages are resolved within 24 hours 100% of the time.

Periodic review of incident management service desk software tickets on a monthly basis

Positive and negative performance will be documented in monthly COR reports and past performance reports.

Adverse Condition Notification

3.5.1

In the event the Contractor finds that a condition or malfunction exists which affects the performance or reliability of the radio equipment, whether or not it affects the Contractor's maintenance capability, Contractor shall notify the COR of this condition or malfunction within one (1) workday

Contractor provides required notifications within one (1) workday 100% of the time

100% Inspection

Positive and negative performance will be documented in monthly

File details come from the government source that posted it. Updated .