DRAFT KC-46- Maintenance Platform System.pdf
PDF 1 MB Posted
- Attached to
- KC-46 Maintenance Platform System Federal contract opportunity
- Solicitation number
- H5WA08
About this file
This document is a Statement of Work (SOW) for the purchase of four sets of the KC-46 Maintenance Platform System. The SOW defines the requirements for the complete design, fabrication, inspection, testing, documentation, delivery, equipment installation, work stand assemblies, labor, and other incidentals necessary to provide the KC-46 Maintenance Platform Systems. Each set includes one main deck cargo door stand, two lower lobe cargo door stands, and one crew entry door stand. The Air Force intends to have an Industry Day and solicits proposals through FedBizOpps for a Firm Fixed Price contract. The NAICS code is 332312 with a size standard of 500 EMP. A site visit is scheduled for July 29, 2024, and interested parties must RSVP by July 22, 2024. The procurement is being conducted by the Department of the Air Force Materiel Command Air Force Sustainment Center.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
For
KC-46 Maintenance Platform System
PREPARED BY:
76 AMXG/MXDEA
4/28/2023
PREAMBLE
Commander’s Safety Intent
The safety of everyone on Tinker AFB is our top priority. All Individuals must accept personal responsibility for safety and seek opportunities for improving the safety of our work environment. Everyone working on Tinker AFB is challenged to find, fix (if able) and report all hazards and near-misses. It is our shared duty to take every reasonable step and precaution to prevent accidents and preserve the health/safety of each Contractor and Government employee.
1. SCOPE
This Statement of Work (SOW) defines the effort required for the purchase of four (4) sets of the KC-46 Maintenance Platform System to include a complete design, fabrication, inspection, testing, documentation, delivery, equipment installation, work stand assemblies, labor and other incidentals necessary to provide the KC-46 Maintenance Platform Systems. The Contractor shall be responsible for insuring all services, parts and components provided under this contract are in accordance with (IAW) the terms and conditions outlined in this Statement of Work (SOW).
Each set of the KC-46 Maintenance Platform System shall include one (1) main deck cargo door stand, two (2) lower lobe cargo door stands, and one (1) crew entry door stand.
2. BACKGROUND
The 76th AMXG requires the purchase of this system for current and future PDM on the KC-46 aircraft. No current stands exist for maintenance purposes on the cargo door areas of the KC-46.
The current stands for the crew entry door only allows for entry and does not account for any future work around the area.
3. REQUIREMENTS AND ITEM DESCRIPTIONS
3.1. Main Deck Cargo Door Stand – The cargo door stands shall meet the specifications/descriptions as defined below:
3.1.1 Platform
Platform must support a minimum working load of 2000 lb.
Stand shall have multiple locations stating maximum load limit Platform workable space shall be 102” deep and 192” wide Platform height shall be adjustable from 150” to 180” from working surface to the ground Stand shall be adjustable using a hydraulic pump (MIL-PRF 83282 or MIL-PRF
87257)
Hydraulic pump shall have operating instructions visible on stand by the pump handle
Hydraulic pump shall have label indicating hydraulic fluid type Hydraulic pump handle shall be removable and have a stowed location Platform shall have a minimum overhang of 6” on the side closest to the aircraft Overhang shall be clear of any objects top or bottom
3.1.2 Railing
Railings on top of the main platform shall be constructed IAW the following requirements:
All railings shall be IAW OSHA standard 1926.502 All railings shall have no more than 19” gaps between the horizontal rails All railing shall be 42 inches tall minimum measured from the surface of the platform There shall not be a rail on the side nearest the aircraft from the platform The Inboard end of the rails shall be adjustable to extend out towards the aircraft
8 to 12 inches Extendable railings shall have stopper to prevent rails from falling out Extendable railings shall have pin hole every 1” for fine adjustments Extendable railings shall include the entire 42” height All edges of the railing and the platform that are touching the aircraft shall have a
3” round rubber bumper, including all inboard sides of the platform as well as the bottom edges of the overhanging platform
The rubber bumpers shall be the only part of the stand to ever contact the aircraft and should thus be the inboard most material at all locations
All railings around the work surface shall have toe boards There shall be no more than 1” from the surface of the platform to the bottom of the toe boards Toe boards shall be 6” in height There shall be no toe boards on the overhang on the aircraft side of the platform The rails near the outboard left side of the platform shall have a secured gate 48” wide to connect to the crew entry door stand Gate shall open by sliding outward and latching securely with a locking pin on the static railing on the inboard side Crew entry door stand and Main cargo door stand shall be able to be used as one operating unit The outboard section of the railing shall have two 48” wide removable rail sections creating a 96” wide opening Removable sections shall have stow locations on the main platform
3.1.3 Fall Restraint
A rigid fall restraint system shall be installed flush with tread plate of main platform at a distance of 3 and ½ feet from outboard side Rail shall run the full width of the main platform Shall have a single fall restraint trolley in the rigid rail system
Rail system must be capable of 5,000lb load without failure Stand shall have fall arrest connection line along the inboard edge of the platform
3.1.4 Miscellaneous
Stand shall be mobile with swivel Casters/wheels towable on rough improved surfaces (pavement with potholes), hangar door tracks, and inclines without causing damage to the stand or the casters/wheels at a minimum of 5 miles per hour Casters shall have a minimum capacity of 10,000 lbs. each Casters shall have swivel lock and brake lock
Stand shall have alternate swivel casters/wheels for fine tuning made my hand once stand is close to aircraft Casters shall be hand crank operated to lower to the ground only when in use Casters shall have a minimum capacity of 5,000 lbs. each Stand shall have a sticker indicating alternate casters are for fine adjustments only Stand shall be able to lock in place using two or more floor locks Stand shall have a tow bar
Tow bar shall have a lunette eye conforming to MS51336 During non-transport, the tow bar shall be stowed and secured so as not to hinder visibility, present a tripping hazard, or release accidentally, for all heights of the stand
Any low hanging surface with a head strike hazard shall be covered in foam Stand shall have air and electric connection points on the main platform
An expandable/retractable air hose shall be connected to the stand along the height of the stand so that a hose can be connected at the bottom of the stand and another at the top with minimum 100psi
An expandable/retractable electric line shall be connected to the stand along the height of the stand so that electric can be ran though to top of stand with 110v
The work stands shall be weatherized to prevent corrosion degradation from being stored outside
The force required to move each stand shall not exceed the values in MIL-STD- 1472H and associated tables, paragraph 5.8.6.5.1. the number of personnel required to move each stand shall not exceed four people
Contractor shall provide a full illustrated parts breakdown and a user’s manual for the stand
3.2. Lower Lobe Cargo Door Stand- The two (2) lower lobe cargo door stands shall meet the specifications/descriptions as defined below:
3.2.1 Platform
Platform must have a minimum working load of 2000 lb.
Stand shall have multiple locations stating maximum load limit Platform workable space shall be 165” deep and 142” wide Platform height shall be adjustable from 60” to 90” from working surface to the ground Stand shall be adjustable using a hydraulic pump (MIL-PRF 83282 or MIL-
PRF 87257)
Hydraulic pump shall have operating instructions visible on stand by the pump handle pump shall have label indicating hydraulic fluid type Hydraulic pump handle shall be removable and have a stowed location
Platform shall have a minimum overhang of 24” on the side closest to the aircraft Overhang shall be clear of any objects top or bottom
3.2.2 Rails
Railings on top of the main platform shall be constructed IAW the following requirements:
All railings shall be IAW OSHA standard 1926.502 All railings shall have no more than 19” gaps between the horizontal rails Forward most railings within 6 feet of the aircraft shall be a total of 96” tall minimum measured from the surface of the platform All other railing shall be 42 inches tall minimum measured from the surface of the platform Where the 96” tall railing meets the aircraft, there shall be an angled extension of 45 degrees by 18” out from the lower rail on the lower half as shown in attached reference drawing
There shall not be a rail on the side nearest the aircraft from the main platform.
The Inboard end of forward and aft rail shall be adjustable to extend out towards the aircraft 8 to 12 inches Extendable railings shall have stopper to prevent rails from falling out Extendable railings shall have pin hole every 1” for fine adjustments Extendable railings shall include the entire 96” height
All edges of the railing and the platform that are touching the aircraft shall have a 3” round rubber bumper, including all inboard sides of the platform as well as the bottom edges of the overhanging platform The rubber bumpers shall be the only part of the stand to ever contact the aircraft and should thus be the inboard most material at all locations All railings around the work surface and stairs shall have toe boards
There shall be no more than 1” from the surface of the platform to the bottom of the toe boards
Toe boards shall be 6” in height There shall be no toe boards on the overhang on the front of the platform
3.2.3 Stairs
Stairs leading up the platform shall lie parallel to the aircraft and must follow
IAW OSHA standard 1910.25 top stair landing edges shall align with platform edge
Stairs shall have a self-closing swing gate across the top of the stairs to prevent falling. This gate shall be attached to the railing on either side of the stairs Gate shall open inward when climbing the stairs Stairs shall be 48” wide Stair treads shall be made with non-slip treads Stairs shall have railings IAW OSHA standard 1926.502 and toe boards meeting specifications above Steps shall be constructed IAW OSHA standard 1910.25 per standard stair requirements The bottom stair step shall not be more than 8” off the ground and be painted yellow Stairs shall have toe boards
3.2.4 Miscellaneous
Stand shall be mobile with swivel Casters/wheels towable on rough improved surfaces (pavement with potholes), hangar door tracks, and inclines without causing damage to the stand or the casters/wheels at a minimum of 5 miles per hour Casters shall have a minimum capacity of 10,000 lbs. each Casters shall have swivel lock and brake lock
Stand shall have alternate swivel casters/wheels for fine tuning once stand is close to aircraft Casters shall be hand crank operated to lower to the ground only when in need Casters shall have a minimum capacity of 5,000 lbs. each Stand shall have a sticker indicating alternate casters are for fine adjustments only Stand shall be able to lock in place using two or more floor locks Stand shall have a tow bar
Tow bar shall have a lunette eye conforming to MS51336 During non-transport, the tow bar shall be stowed and secured so as not to hinder visibility, present a tripping hazard, or release accidentally, for all heights of the stand
Any low hanging surface with a head strike hazard shall be covered in foam Stand shall have air and electric connection points
An expandable/retractable air hose shall be connected to the stand along the height of the stand so that a hose can be connected at the bottom of the stand and another at the top with minimum 100psi
An expandable/retractable electric line shall be connected to the stand along the height of the stand so that electric can be ran through to top of stand with 110v
Work stands shall be weatherized to prevent corrosion degradation from being stored outside
The force required to move each stand shall not exceed the values in MIL-STD- 1472G and associated tables, paragraph 5.8.6.5.1. the number of personnel required to move each stand shall not exceed four people
Contractor shall provide a full illustrated parts breakdown and a user’s manual for the stand
3.3. Crew Entry Door Stand - The crew entry door stands shall meet the specifications/descriptions as defined below:
3.3.1 Platform
Platform must support a minimum working load of 2000 lb.
Stand shall have multiple locations stating maximum load limit Platform workable space shall be 102” deep and 192” wide Platform height shall be adjustable from 150” to 180” from working surface to the ground Stand shall be adjustable using a hydraulic pump (MIL-PRF 83282 or MIL-
PRF 87257)
Hydraulic pump shall have operating instructions visible on stand by the pump handle Hydraulic pump shall have label indicating hydraulic fluid type Hydraulic pump handle shall be removable and have a stowed location
Platform shall have a minimum overhang of 6” on the side closest to the aircraft Overhang shall be clear of any objects top or bottom
3.3.2 Rails
Railings on top of the main platform shall be constructed IAW the following requirements:
All railings shall be IAW OSHA standard 1926.502 All railings shall have no more than 19” gaps between the horizontal rails All railing shall be 42” tall minimum measured from the surface of the platform There shall not be a rail on the side nearest the aircraft from the main platform.
The Inboard end of forward side rail shall be adjustable to extend out towards the aircraft 8 to 12 inches Extendable railings shall have stopper to prevent rails from falling out Extendable railings shall have pin hole every 1” for fine adjustments
Extendable railings shall include the entire 42” height All edges of the railing and the platform that are touching the aircraft shall have a
3” round rubber bumper, including all inboard sides of the platform as well as the bottom edges of the overhanging platform The rubber bumpers shall be the only part of the stand to ever contact the aircraft and should thus be the inboard most material at all locations All railings around the work surface and stairs shall have toe boards
There shall be no more than 1” from the surface of the platform to the bottom of the toe boards
Toe boards shall be 6” in height There shall be no toe boards on the overhang on the aircraft side of the platform The rails near the outboard right side of the platform shall have a secured gate 48” wide to connect to the main deck cargo door stand Gate shall open by sliding outward and latching securely with a locking pin on the static railing on the inboard side Crew entry door stand and Main cargo door stand shall be able to be used as one operating unit
3.3.3 Stairs
Stairs leading up the platform shall lie parallel to the aircraft and must follow IAW OSHA standard 1910.25 top stair landing edges shall align with platform edge
Stairs shall have a self-closing swing gate across the top of the stairs to prevent falling. This gate shall be attached to the railing on either side of the stairs Gate shall open inward when climbing the stairs Stairs shall be 48” wide Stair treads shall be made with non-slip treads Stairs shall have railings IAW OSHA standard 1926.502 and toe boards meeting specifications above Steps shall be constructed IAW OSHA standard 1910.25 per standard stair requirements The bottom stair step shall not be more than 8” off the ground and be painted yellow Stairs shall have toe boards
3.3.4 Miscellaneous
Stand shall be mobile with swivel Casters/wheels towable on rough improved surfaces (pavement with potholes), hangar door tracks, and inclines without causing damage to the stand or the casters/wheels at a minimum of 5 miles per hour Casters shall have a minimum capacity of 10,000 lbs. each Casters shall have swivel lock and brake lock
Stand shall have alternate swivel casters/wheels for fine tuning made my hand once stand is close to aircraft
Casters shall be hand crank operated to lower to the ground only when in use Casters shall have a minimum capacity of 5,000 lbs. each Stand shall have a sticker indicating alternate casters are for fine adjustments only Stand shall be able to lock in place using two or more floor locks Stand shall have a tow bar
Tow bar shall have a lunette eye conforming to MS51336 During non-transport, the tow bar shall be stowed and secured so as not to hinder visibility, present a tripping hazard, or release accidentally, for all heights of the stand
Any low hanging surface with a head strike hazard shall be covered in foam Stand shall have air and electric connection points
An expandable/retractable air hose shall be connected to the stand along the height of the stand so that a hose can be connected at the bottom of the stand and another at the top with minimum 100psi
An expandable/retractable electric line shall be connected to the stand along the height of the stand so that electric can be ran through to top of stand with 110v
The work stands shall be weatherized to prevent corrosion degradation from being stored outside
The force required to move each stand shall not exceed the values in MIL-STD- 1472G and associated tables, paragraph 5.8.6.5.1. the number of personnel required to move each stand shall not exceed four people
Contractor shall provide a full illustrated parts breakdown and a user’s manual for the stand
3.4. Installation - The Contractor shall be responsible for equipment delivery to Building 9502 at Tinker AFB, OK 73145. The Contractor shall be responsible for offloading equipment and moving equipment to the installation area (Building 9502). The Contractor shall be responsible for all parts, labor, and materials necessary for and to fully complete the installation of the stands, and ensure that the completed system is fully functional for Performance Verification/Acceptance Testing.
4. GENERAL REQUIREMENTS
4.1. Hours of Operation: The Contractor shall perform the work required under this contract during the following days and hours: Monday through Friday, 7am-5pm. If work hours are required outside the hours stated, the Contractor shall contact the Government POC for approval from the CO. Upon approval from the CO, the Government Subject Matter Expert (SME) or Government POC must be present with the Contractor.
These dates and hours exclude Federal Holidays, base closures due to inclement weather, and furlough days, as applicable.
4.2. Environmental Protection & Safety: The Contractor shall be knowledgeable of and comply with all applicable federal, state and local laws, regulations, instructions and requirements regarding environmental protection and occupational safety and health. The Contractor shall comply with any laws, instructions or regulation changes during the term of this contract.
Contractors shall be compliant Tinker Air Force Base (TAFB) Supplement to Air Force Instruction (AFI) 32-7086, “Hazardous Materials Management”, Tinker AFB procedures per Tinker Air Force Base Instruction (TAFBI) 32-7004, “Hazardous Waste Management”, and Complex procedures per Oklahoma City Air Logistics Complex (OC-ALC) Sup to AFI 32-7086, “Hazardous Material Management” and OC-ALCI 32-101 “Air Quality Record Keeping Procedure”. Publications are available digitally on e-Publishing website at www.epublishing.
af.mil for downloading or ordering.
4.3. Spills: Upon occurrence of any spill that could enter the storm system or cause any harmful environment effects, the Contractor shall immediately call 911 to report the incident. When possible, the Contractor shall use a base telephone to receive help from Tinker AFB 911. If using a cell phone, the Contractor shall request Tinker AFB 911. The Contractor shall immediately report all environmental violations to the GPOC and UEC. The Contractor shall provide five (5) copies of a typed or written report about the incident within four (4) clock hours as follows:
One (1) copy to CO, two (2) copies to the GPOC, a copy for UEC and one (1) copy for record.
The format of the report shall be left up to the Contractor, but the report shall contain the following information:
1.) Name and contact number of person reporting the spill 2.) Date and time of incident 3.) Location and source of spill 4.) Substance or pollutant spilled 5.) Amount spilled and rate of discharge 6.) Any damages or injuries involved 7.) Extent of area impacted 8.) Potential hazards 9.) Actions taken 10.) Organizations contacted 11.) Remarks Section - that addresses the cause of the spill (e.g. human error, equipment, etc.) and whether 911 was called and which agencies responded.
4.4. Housekeeping: The Contractor shall keep the work areas clean and neat IAW industry standards, OSHA, fire and safety standards, and this SOW.
4.5. Foreign Object Damage (FOD) and Dropped Object Prevention: (SS) Contractor personnel who work in or travel though areas near operational and production aircraft, engines, munitions, missiles, drones, space systems, support equipment, Aerospace Ground Equipment (AGE), trainers, and the Contactor personnel operating vehicles and equipment on flight lines, runways, taxiways, parking ramps, and in aircraft hangers and maintenance areas are required to receive the FOD/DOP training and to comply with AFI 36-2650, AFMC Supplement 1, paragraph 9.2., and A4.4.4. (Initial)/A4.4.5. (Refresher). The Contractor and Contractor personnel shall acknowledge the FOD/DOP training either by viewing the Digital Versatile Disc
(DVD) provided by the Government POC or the YouTube site, http://www.youtube.com/watch?v=tYcbodjFPnM.
The Contract Manager shall provide written certification to the Government POC for each employee within ten (10) business days after the contract award date. The certification shall have the title of the training, the name of the person who received the training, and the date of the training. The Contractor shall also ensure all new employees view the FOD/DOP training and provide written certification of training to the Government POC prior to the employees starting work in the OC-ALC shops. Every 36 Months, the Contractor and Contractor personnel shall be required to review the FOD/DOP training and to provide written certification to the Government
POC.
4.6. Privately Owned Motor Vehicles (POV): Contractor personnel shall comply with the directives pertaining to operation of POVs on Tinker AFB per AFMAN 31-116, in its entirety, “Motor Vehicle Traffic Supervision”. The Contractor shall comply with Tinker AFBI 24-302, in its entirety for the operation of POVs within Tinker AFB.’
4.7. Visitors Pass: The Contractor shall contact the Government POC seven (7) business days before arriving on Tinker AFB in order to make arrangements for Visitors Passes. The Government POC will assign a sponsor for the Contractor from within the organization. The Contractor and the sponsor shall arrange to meet at Pass and Registration, Building 6611 at the Tinker Gate which is South of I-40 off of Air Depot. The Contractor shall provide two (2) forms of identification, one of which shall be a picture ID, to the 72 SFS. The 72 SFS will provide an AF Form 75, Visitors Pass, which will be valid for up to thirty (30) calendar days.
4.8. Foreign Nationals: The Contractor shall notify the Government POC before sending a Foreign National representative to perform services. Special rules apply for foreign nationals visiting a US Government facility.
4.9. Safety and Health on Government Installations: While performing work under this contract on a Government installation, the Contractor shall comply with federal, state and local regulations, and AFI 91-203, “Air Force Consolidated Occupational Safety Instruction”, as established by this contract and Appendix C. The Contractor shall notify the CO, Government POC, and Government Contract Administrator (CA) within one (1) business day of any injuries that occur to contractor personnel while they are on the installation. The Contractor shall notify the CO, Government POC, and Government CA within one (1) business day of damage to Government property or equipment during the execution of the contract.
4.10. Combating Trafficking in Persons: IAW DFARS PGI 222.17, the COR shall pursue, as appropriate, the following methods of monitoring the Contractor’s performance regarding trafficking in persons such that non-compliances with FAR clause 52.222-50 are brought to the immediate attention of the Contracting Officer:
a. Keep the lines of communication open with the Contractor. At the Post-Award conference, remind the Contractor of his contractual responsibilities to notify the government if the Contractor receives notification of any alleged violations to this policy or if actions have been taken against the Contractor employees, subcontractor’s or subcontractor employees pursuant to the clause.
b. When appropriate, encourage Contractor to complete Human Trafficking Awareness Training.
c. Encourage the Contractor to take steps to investigate and eliminate slavery and human trafficking in their supply chains and to publish information for consumer awareness.
d. Periodically access the Department of State’s Trafficking in Person (TIP) website for updates and to view the latest reports. http://www.state.gov/g/tip
Commanders Safety Intent: The safety of everyone on Tinker AFB is our top priority. All Individuals must accept personal responsibility for safety and seek opportunities for improving the safety of our work environment. Everyone working on Tinker AFB is challenged to find, fix (if able) and report all hazards and nearmisses. It is our shared duty to take every reasonable step and precaution to prevent accidents and preserve the health/safety of each contractor and government employee.
4.11. Speak up for safety: Safety surety is an integral part of our overall goal of establishing a world class safety and health program. Our “Speak Out for Safety” initiative ensures a partnership with contractors and government employees to further enhance safety to ensure we are looking out for all our partners and empowers all employees to actively participate in each other’s safety.
A safe workplace is everyone's business. As part of the contract team, military, civilian and contractor personnel are empowered to Speak Out for Safety (S.O.S.) when they observe an unsafe act.
Events that present imminent danger to personnel or catastrophic damage to property we empower our employees to intercede to ensure continued safe operations.
4.12. Communicating Hazards Of Workplace (CHOW): Contractor’s onsite representative communicates all hazards being introduced to the worksite by the Contractor. This is accomplished prior to commencement of work and refreshed daily during performance, IAW Contractor’s Site Safety Plan.
4.13. Safety and Health Plan: The Contractor shall be responsible for compliance with the OSHA Public Law 91-596. The Contractor shall submit a Safety and Health Plan (SHP) and corresponding site safety checklist to the CO and the COR (see Appendix C).
4.14. Emergency Procedures: The Contractor personnel shall follow the direction of the Government personnel with regard to emergency procedures, such as fire, tornado, active shooter, bomb threats, or other emergency. It is the responsibility of the Contractor to provide guidance and to establish procedures for its employees to respond to an emergency. It is the Contractor’s responsibility to account for their employees following an emergency evacuation.
The Contractor personnel shall participate with the Government personnel in all fire and tornado drills at no additional cost to the Government.
Appendix A – Main Deck Cargo Door Stand Reference
Appendix B – Lower Lobe Cargo Door Stands Reference
Appendix C – Crew Entry Door Stand Reference
File details come from the government source that posted it. Updated .