Draft_Drawings_1.pdf
PDF 11 MB Posted
- Attached to
- FONE VC BLOCK WALL AND DRAINAGE
- Solicitation number
- 140P4225B0003
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Draft_Specifications_1.pdf | ||
| Sources_Sought_1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE INTERIOR
UNITED STATES
NATIONAL PARK SERVICE
DENVER SERVICE CENTER OF
PKG.
NO. SHEET
STATEREGION
LOCATION WITHIN PARK
NAME OF PARK
TITLE OF DRAWING DRAWING NO.
COUNTY
REVISIONS Date InitialSheetMarkA/E FIRMS COVER SHEET
FORT NECESSITY NATIONAL BATTLEFIELD
PENNSYLVANIA
DESIGN DEVELOPMENT
VICINITY PLAN
AutoCAD SHX Text
FORT NECESSITY VISITOR CENTER
AutoCAD SHX Text
THIS PROJECT
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
WASHINGTON PKWY
AutoCAD SHX Text
WASHINGTON PKWY
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
NATIONAL PIKE
AutoCAD SHX Text
NELSON RD.
AutoCAD SHX Text
NATIONAL PIKE
AutoCAD SHX Text
FORT NECESSITY NATIONAL BATTLEFIELD
AutoCAD SHX Text
GREAT MEADOWS AMPHITHEATER
AutoCAD SHX Text
WASHINGTON PKWY
AutoCAD SHX Text
AutoCAD SHX Text
PENNSYLVANIA
AutoCAD SHX Text
AutoCAD SHX Text
CIVIL:
AutoCAD SHX Text
SORBA - DULLES, VA
AutoCAD SHX Text
STRUCTURAL:
AutoCAD SHX Text
MCMULLAN - RESTON, VA
AutoCAD SHX Text
SCALE OF MILES
AutoCAD SHX Text
AutoCAD SHX Text 5.7
AutoCAD SHX Text 5.7
AutoCAD SHX Text
AutoCAD SHX Text 179591
AutoCAD SHX Text
U.S. DEPARTMENT OF THE INTERIOR
AutoCAD SHX Text REHABILITATE VISITOR CENTER BLOCK RETAINING WALL AND SUBSURFACE DRAINAGE SYSTEM PENNSYLVANIA
AutoCAD SHX Text
PMIS # FONE 306943
AutoCAD SHX Text SHEET SUB SHEET TITLE OF SHEET SUB SHEET TITLE OF SHEET TITLE OF SHEET 1 G00 COVER SHEET G00 COVER SHEET COVER SHEET 2 C1 EXISTING CONDITIONS C1 EXISTING CONDITIONS EXISTING CONDITIONS 3 C2 DEMOLITION PLAN C2 DEMOLITION PLAN DEMOLITION PLAN 4 C3 SITE, GRADING AND UTILITY PLAN C3 SITE, GRADING AND UTILITY PLAN SITE, GRADING AND UTILITY PLAN 5 C4 EROSION & SEDIMENT CONTROL PLAN PHASE 1 C4 EROSION & SEDIMENT CONTROL PLAN PHASE 1 EROSION & SEDIMENT CONTROL PLAN PHASE 1 6 C5 EROSION & SEDIMENT CONTROL PLAN PHASE 2 C5 EROSION & SEDIMENT CONTROL PLAN PHASE 2 EROSION & SEDIMENT CONTROL PLAN PHASE 2 7 C6 SITE DETAILS C6 SITE DETAILS SITE DETAILS 8 C7 SITE DETAILS C7 SITE DETAILS SITE DETAILS 9 S0.1 DESIGN NOTES S0.1 DESIGN NOTES DESIGN NOTES 10 S1.0 RETAINING WALL NEW WORK PLAN S1.0 RETAINING WALL NEW WORK PLAN RETAINING WALL NEW WORK PLAN 11 S2.0 SECTIONS AND DETAILS S2.0 SECTIONS AND DETAILS SECTIONS AND DETAILS 12 S2.1 ELEVATIONSS2.1 ELEVATIONSELEVATIONS
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text
LOCATION PLAN
AutoCAD SHX Text
SCALE: 1/128"=1'-0"
AutoCAD SHX Text 128'
AutoCAD SHX Text
AutoCAD SHX Text 128'
AutoCAD SHX Text 256'
AutoCAD SHX Text
FORT NECESSITY NATIONAL BATTLEFIELD
EXISTING KEYNOTES:
EXISTING STORM DRAIN INLET.
EXISTING STORM CLEANOUT.
EXISTING BUILDING COLUMN.
EXISTING PIPE RAILING.
EXISTING CONCRETE RETAINING WALL WITH SPLIT
FACE CMU VENEER AND CAP.
EXISTING LANDSCAPE BLOCK WALL.
NOTES:
1. A FULL TOPOGRAPHIC SURVEY HAS NOT BEEN
PERFORMED BY THIS FIRM OR PROVIDED BY
NPS.
2. EXISTING CONDITIONS SHOWN HEREON BASED
UPON MEASUREMENTS COLLECTED ON SITE
OCTOBER 13, 2022.
3. EXISTING ELEVATIONS SHOWN COLLECTED
WITH AUTO-LEVEL AND ROD READINGS ON
SITE ON OCTOBER 13, 2022.
EXISTING HSS GATE POST.7
99.999.6
100.1 100.1 100.2
100.4100.2
100.0100.0
100.0 99.9 99.9 99.9
99.9 99.7
98.396.5
99.8
100.0
97.1 96.1
98.798.8
99.5
97.3
2.9%
1.1%
2.3%
1.
2%2.
0%
2.
3%
0.
9%
0.
5%
1.
2%
3.
3%
1.9%
2.
8%
3.7%
14.4%
0.5%
0.
9%
6.4%
.8
1.0%
0.5%0.3%
1.
5%
2.
6%
0.6%
1.2%
0.
5%
1.0%
100 100
EXISTING
MECH.
EQUIP. &
CONC. PAD
5/
/2
:3
R
O N
.K
IN
G
4.
1S
(L M
S
TE
C H
) P :\2
2\
6_
N
PS
F O
N E
R W
\0 3_
D R
AW
IN
G S\
C
IV
IL
\C
1.
D
W G
RMaine Rectangle
RMaine Rectangle
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text A/E FIRM: STRUCTURAL: McMullan Consulting Engineers Reston, VA CIVIL: Sorba Engineering Dulles, VA
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text 06/09/2023
AutoCAD SHX Text
RK
AutoCAD SHX Text
RK
AutoCAD SHX Text
MM
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text 179591
AutoCAD SHX Text
PMIS/ PKG NO.
AutoCAD SHX Text 320561
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
AutoCAD SHX Text
FORT NECESSITY - NATIONAL ROAD INTERPRETIVE AND EDUCATION CENTER
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1" = 5'
AutoCAD SHX Text C1
AutoCAD SHX Text
EXISTING CONDITIONS
AutoCAD SHX Text
RMaine Image
RMaine Image
RMaine Text Box
100 100
EXISTING
MECH.
EQUIP. &
CONC. PAD
DEMOLITION KEYNOTES:
SAW CUT AND REMOVE EXISTING CONCRETE SLAB
ON GRADE.
REMOVE EXISTING STEEL GATE POSTS.
REMOVE EXISTING RUBBERIZED PLAYGROUND
SURFACE. Keep the demo to as small an area as possible
DEMO EXISTING STORM DRAIN INLET.
1 REMOVAL OF CONCRETE
SLAB ON GRADE
REMOVAL OF PLAYGROUND
SURFACE.
DEMOLITION LEGEND:
5/
/2
:3
R
O N
.K
IN
G
4.
1S
(L M
S
TE
C H
) P :\2
2\
6_
N
PS
F O
N E
R W
\0 3_
D R
AW
IN
G S\
C
IV
IL
\C
2.
D
W G
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text A/E FIRM: STRUCTURAL: McMullan Consulting Engineers Reston, VA CIVIL: Sorba Engineering Dulles, VA
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text 06/09/2023
AutoCAD SHX Text
RK
AutoCAD SHX Text
RK
AutoCAD SHX Text
MM
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text 179591
AutoCAD SHX Text
PMIS/ PKG NO.
AutoCAD SHX Text 320561
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
AutoCAD SHX Text
FORT NECESSITY - NATIONAL ROAD INTERPRETIVE AND EDUCATION CENTER
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1" = 5'
AutoCAD SHX Text C2
AutoCAD SHX Text
DEMOLITION PLAN
AutoCAD SHX Text
RMaine Rectangle
RMaine Image
RMaine Image
RMaine Rectangle
RMaine
100 100
EXISTING
MECH.
EQUIP. &
CONC. PAD
00 03
MAT
99 95
99 99
00 03
MAT 00 02
MAT
99 94
MAT 99 88
MAT
99 96
MAT
99 86
MAT
99 93
MAT
99 96
TD
00 14
TD
00 07
TD
99 61
TD
99 68
MAT99 61
MAT
99 73
MAT
99 90
MAT
99 99
MAT
00 14
MAT
00 22
MAT
00 15 00 10
99 73
99 85
99 97
00 19
00 25
00 31
00 20
00 08 00 16
00 29
00 41
HP
00 34
00 27
1.48%
0.
1.
1.64%
1.80%
1.96%
1.73%
1.51%
1.13%
1.
1.
2.
2.
2.
1.
0.51%
0.
1.01%
1.
1.41%
1.97%
1.28%
MATMAT
MAT
MAT
MAT
MAT
7' - 4" HDPE STRM
2' - 4" HDPE STRM
16' - 4" HDPE STRM
8' - 4" HDPE STRM
EX 12" STRM
MAT
MAT
MAT
NEW 4" HDPE STORM PIPE, MINIMUM 0.5% SLOPE, MINIMUM 1'
COVER. CONFIRM PIPE LENGTH, SLOPE, AND COVER
REQUIREMENTS IN THE FIELD.
CONNECT NEW HDPE STORM PIPE TO EXISTING STORM
NETWORK AT DRAIN INLET, MINIMUM 0.5% SLOPE. CONFIRM
PIPE LENGTH, SLOPE, AND COVER REQUIREMENTS IN THE
FIELD.
EXISTING STORM PIPE AND STRUCTURE LOCATIONS SHOWN
AS APPROXIMATE FROM EXISTING DRAWINGS DATED
07/19/2002 AND MUST BE VERIFIED IN THE FIELD.
NEW CONCRETE SLAB ON
GRADE
NEW PLAYGROUND
SURFACE.
SITE LEGEND:
SITE KEYNOTES:
NEW TRENCH DRAIN INLET ACO; KLASSIKDRAIN K100 LOAD
CLASS A WITH TYPE 451D STAINLESS STEEL PERFORATED
GRATE OR APPROVED EQUAL. SEE DETAILS 1, 2, 3 AND 4 ON
SHEET C7.
NEW 5" MIN. THICKNESS CONCRETE SLAB ON GRADE. SEE
STRUCTURAL DRAWINGS FOR DETAIL. SEE DETAIL 5 ON
SHEET C7.
REPLACE RUBBERIZED PLAYGROUND SURFACE WITH 5"
THICK CONCRETE WITH APPROPRIATE BASE FILL AND
COMPACTION.
EXISTING CONCRETE SLAB ON GRADE TO REMAIN.
CONNECT NEW 4" HDPE STORM PIPE TO TRENCH DRAIN.
CONSTRUCT DRIP EDGE. SEE STRUCTURAL SHEET S2.0,
DETAIL 4 FOR DETAIL.
CONNECT NEW HDPE STORM PIPE TO EXISTING STORM
NETWORK WITH TEE, MINIMUM 0.5% SLOPE. CONFIRM PIPE
LENGTH, SLOPE, AND COVER REQUIREMENTS IN THE FIELD
5/
/2
:5
R
O N
.K
IN
G
4.
1S
(L M
S
TE
C H
) P :\2
2\
6_
N
PS
F O
N E
R W
\0 3_
D R
AW
IN
G S\
C
IV
IL
\C
3.
D
W G
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text A/E FIRM: STRUCTURAL: McMullan Consulting Engineers Reston, VA CIVIL: Sorba Engineering Dulles, VA
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text 06/09/2023
AutoCAD SHX Text
RK
AutoCAD SHX Text
RK
AutoCAD SHX Text
MM
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text 179591
AutoCAD SHX Text
PMIS/ PKG NO.
AutoCAD SHX Text 320561
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
AutoCAD SHX Text
FORT NECESSITY - NATIONAL ROAD INTERPRETIVE AND EDUCATION CENTER
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1" = 5'
AutoCAD SHX Text C3
AutoCAD SHX Text
SITE, GRADING AND UTILITY PLAN
AutoCAD SHX Text
RMaine Rectangle
RMaine Image
RMaine Image
RMaine Rectangle
RMaine
100 100
EXISTING
MECH.
EQUIP. &
CONC. PAD
SF
SF
SF
SFSF
SF
IP
IP
LOD LOD
LOD
LOD
LOD
LOD LOD
LOD
LOD
LOD
LOD
LODLOD
LIMITS OF DISTURBANCE
SILT FENCE
STONE INLET PROTECTION
TRENCH DRAIN STONE
INLET PROTECTION
EROSION & SEDIMENT LEGEND:EROSION & SEDIMENT NOTES:
1. SILT FENCE TO BE INSTALLED PRIOR TO ANY
DEMOLITION OR CONSTRUCTION.
2. EROSION & SEDIMENT CONTROLS TO REMAIN
IN PLACE UNTIL COMPLETION OF
CONSTRUCTION.
SF
LOD
IP
TIP
5/
/2
:0
R
O N
.K
IN
G
4.
1S
(L M
S
TE
C H
) P :\2
2\
6_
N
PS
F O
N E
R W
\0 3_
D R
AW
IN
G S\
C
IV
IL
\C
4.
D
W G
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text A/E FIRM: STRUCTURAL: McMullan Consulting Engineers Reston, VA CIVIL: Sorba Engineering Dulles, VA
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text 06/09/2023
AutoCAD SHX Text
RK
AutoCAD SHX Text
RK
AutoCAD SHX Text
MM
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text 179591
AutoCAD SHX Text
PMIS/ PKG NO.
AutoCAD SHX Text 320561
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
AutoCAD SHX Text
FORT NECESSITY - NATIONAL ROAD INTERPRETIVE AND EDUCATION CENTER
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1" = 5'
AutoCAD SHX Text C4
AutoCAD SHX Text
EROSION & SEDIMENT CONTROL PLAN PHASE 1
AutoCAD SHX Text
RMaine Rectangle
RMaine Image
RMaine Image
RMaine Rectangle
RMaine
100 100
EXISTING
MECH.
EQUIP. &
CONC. PAD
SF
SF
SF
SFSF
SF
IP
IP
TIP
TIP
TIP
TIP
LOD LOD
LOD
LOD
LOD
LOD LOD
LOD
LOD
LOD
LOD
LODLOD
TIP
TIP
TIP
LIMITS OF DISTURBANCE
SILT FENCE
STONE INLET PROTECTION
TRENCH DRAIN STONE
INLET PROTECTION
EROSION & SEDIMENT LEGEND:EROSION & SEDIMENT NOTES:
1. SILT FENCE TO BE INSTALLED PRIOR TO ANY
DEMOLITION OR CONSTRUCTION.
2. EROSION & SEDIMENT CONTROLS TO REMAIN
IN PLACE UNTIL COMPLETION OF
CONSTRUCTION.
SF
LOD
IP
TIP
5/
/2
:5
R
O N
.K
IN
G
4.
1S
(L M
S
TE
C H
) P :\2
2\
6_
N
PS
F O
N E
R W
\0 3_
D R
AW
IN
G S\
C
IV
IL
\C
5.
D
W G
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text A/E FIRM: STRUCTURAL: McMullan Consulting Engineers Reston, VA CIVIL: Sorba Engineering Dulles, VA
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text 06/09/2023
AutoCAD SHX Text
RK
AutoCAD SHX Text
RK
AutoCAD SHX Text
MM
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text 179591
AutoCAD SHX Text
PMIS/ PKG NO.
AutoCAD SHX Text 320561
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
AutoCAD SHX Text
FORT NECESSITY - NATIONAL ROAD INTERPRETIVE AND EDUCATION CENTER
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1" = 5'
AutoCAD SHX Text C5
AutoCAD SHX Text
EROSION & SEDIMENT CONTROL PLAN PHASE 2
AutoCAD SHX Text
RMaine Rectangle
RMaine Image
RMaine Image
RMaine Rectangle
RMaine
STANDARD EROSION & SEDIMENT NOTES:
1. ALL EARTH DISTURBANCES, INCLUDING CLEARING
AND GRUBBING AS WELL AS CUTS AND FILLS SHALL
BE DONE IN ACCORDANCE WITH THE APPROVED E&S
PLAN. A COPY OF THE APPROVED DRAWINGS
(STAMPED, SIGNED, AND DATED BY THE REVIEWING
AGENCY) MUST BE AVAILABLE AT THE PROJECT SITE
AT ALL TIMES. THE REVIEWING AGENCY SHALL BE
NOTIFIED OF ANY CHANGES TO THE APPROVED PLAN
PRIOR TO IMPLEMENTATION OF THOSE CHANGES.
THE REVIEWING AGENCY MAY REQUIRE A WRITTEN
SUBMITTAL OF THOSE CHANGES FOR REVIEW AND
APPROVAL AT ITS DISCRETION.
2. AT LEAST 7 DAYS PRIOR TO STARTING ANY EARTH
DISTURBANCE ACTIVITIES, INCLUDING CLEARING
AND GRUBBING, THE OWNER AND/OR OPERATOR
SHALL INVITE ALL CONTRACTORS, THE LANDOWNER,
APPROPRIATE MUNICIPAL OFFICIALS, THE E&S PLAN
PREPARER, THE PCSM PLAN PREPARER, THE
LICENSED PROFESSIONAL RESPONSIBLE FOR
OVERSIGHT OF CRITICAL STAGES OF
IMPLEMENTATION OF THE PCSM PLAN, AND A
REPRESENTATIVE FRO MTHE LOCAL CONSERVATION
DISTRICT TO AN ON-SITE PRECONSTRUCTION
MEETING.
3. AT LEAST 3 DAYS PRIOR TO STARTING ANY EARTH
DISTURBANCE ACTIVITIES, OR EXPANDING INTO AN
AREA PREVIOUSLY UNMARKED, THE PENNSYLVANIA
ONE CALL SYSTEM INC. SHALL BE NOTIFIED AT
1-800-242-1776 FOR THE LOCATION OF EXISTING
UNDERGROUND UTILITIES.
4. ALL EARTH DISTURBANCE ACTIVITIES SHALL
PROCEED IN ACCORDANCE WITH THE SEQUENCE
PROVIDED ON THE PLAN DRAWINGS. DEVIATION
FROM THAT SEQUENCE MUST BE APPROVED IN
WRITING FROM THE LOCAL CONSERVATION
DISTRICT OR BY THE DEPARTMENT PRIOR TO
IMPLEMENTATION.
5. AREAS TO BE FILLED ARE TO BE CLEARED,
GRUBBED, AND STRIPPED OF TOPSOIL TO REMOVE
TREES, VEGETATION, ROOTS AND OTHER
OBJECTIONABLE MATERIAL.
6. CLEARING, GRUBBING, AND TOPSOIL STRIPPING
SHALL BE LIMITED TO THOSE AREAS DESCRIBED IN
EACH STAGE OF THE CONSTRUCTION SEQUENCE.
GENERAL SITE CLEARING, GRUBBING AND TOPSOIL
STRIPPING MAY NOT COMMENCE IN ANY STAGE OR
PHASE OF THE PROJECT UNTIL THE E&S BMPS
SPECIFIED BY THE BMP SEQUENCE FOR THAT STAGE
OR PHASE HAVE BEEN INSTALLED AND ARE
FUNCTIONING AS DESCRIBED IN THIS E&S PLAN.
7. AT NO TIME SHALL CONSTRUCTION VEHICLES BE
ALLOWED TO ENTER AREAS OUTSIDE THE LIMIT OF
DISTURBANCE BOUNDARIES SHOWN ON THE PLAN
MAPS. THESE AREAS MUST BE CLEARLY MARKED
AND FENCED OFF BEFORE CLEARING AND
GRUBBING OPERATIONS BEGIN.
8. TOPSOIL REQUIRED FOR THE ESTABLISHMENT OF
VEGETATION SHALL BE STOCKPILED AT THE
LOCATION(S) SHOWN ON THE PLAN MAP(S) IN THE
AMOUNT NECESSARY TO COMPLETE THE FINISH
GRADING OF ALL EXPOSED AREAS THAT ARE TO BE
STABILIZED BY VEGETATION. EACH STOCKPILE
SHALL BE PROTECTED IN THE MANNER SHOWN ON
THE PLAN DRAWINGS. STOCKPILE HEIGHTS SHALL
NOT EXCEED 35 FEET. STOCKPILE SLOPES SHALL BE
2H:1V OR FLATTER.
9. IMMEDIATELY UPON DISCOVERING UNFORESEEN
CIRCUMSTANCES POSING THE POTENTIAL FOR
ACCELERATED EROSION AND/OR SEDIMENT
POLLUTION, THE OPERATOR SHALL IMPLEMENT
APPROPRIATE BEST MANAGEMENT PRACTICES TO
MINIMIZE THE POTENTIAL FOR EROSION AND
SEDIMENT POLLUTION AND NOTIFY THE LOCAL
CONSERVATION DISTRICT AND/OR THE REGIONAL
OFFICE OF THE DEPARTMENT.
10. ALL BUILDING MATERIALS AND WASTES SHALL BE
REMOVED FROM THE SITE AND RECYCLED OR
DISPOSED OF IN ACCORDANCE WITH THE
DEPARTMENT'S SOLID WASTE MANAGEMENT
REGULATIONS AT 25 PA. CODE 260.1 ET SEQ., 271.1,
AND 287.1 ET. SEQ. NO BUILDING MATERIALS OR
WASTES OR UNUSED BUILDING MATERIALS SHALL BE
BURNED, BURIED, DUMPED, OR DISCHARGED AT THE
SITE.
11. ALL OFF-SITE WASTE AND BORROW AREAS MUST
HAVE AN E&S PLAN APPROVED BY THE LOCAL
CONSERVATION DISTRICT OR THE DEPARTMENT
FULLY IMPLEMENTED PRIOR TO BEING ACTIVATED.
12. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING
THAT ANY MATERIAL BROUGHT ON SITE IS CLEAN
FILL. FORM FP-001 MUST BE RETAINED BY THE
PROPERTY OWNER FOR ANY FILL MATERIAL
AFFECTED BY A SPILL OR RELEASE OF A REGULATED
SUBSTANCE BUT QUALIFYING AS CLEAN FILL DUE TO
ANALYTICAL TESTING.
13. ALL PUMPING OF WATER FROM ANY WORK AREA
SHALL BE DONE ACCORDING TO THE PROCEDURE
DESCRIBED IN THIS PLAN, OVER UNDISTURBED
VEGETATED AREAS.
14. VEHICLES AND EQUIPMENT MAY NEITHER ENTER
DIRECTLY NOR EXIT DIRECTLY FROM LOTS
__(SPECIFY LOT NUMBERS)___ ONTO ____(SPECIFY
ROAD NAMES)____.
15. UNTIL THE SITE IS STABILIZED, ALL EROSION AND
SEDIMENT BMPS SHALL BE MAINTAINED PROPERLY.
MAINTENANCE SHALL INCLUDE INSPECTIONS OF ALL
EROSION AND SEDIMENT BMPS AFTER EACH
RUNOFF EVENT AND ON A WEEKLY BASIS. ALL
PREVENTATIVE AND REMEDIAL MAINTENANCE
WORK, INCLUDING CLEAN OUT, REPAIR,
REPLACEMENT, REGRADING, RESEEDING,
REMULCHING AND RENETTING MUST BE
PERFORMED IMMEDIATELY. IF THE E&S BMPS FAIL
TO PERFORM AS EXPECTED, REPLACEMENT BMPS,
OR MODIFICATIONS OF THOSE INSTALLED WILL BE
REQUIRED.
16. A LOG SHOWING DATES THAT E&S BMPS WERE
INSPECTED AS WELL AS ANY DEFICIENCIES FOUND
AND THE DATE THEY WERE CORRECTED SHALL BE
MAINTAINED ON THE SITE AND BE MADE AVAILABLE
TO REGULATORY AGENCY OFFICIALS AT THE TIME
OF INSPECTION.
17. SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY
OR SIDEWALK SHALL BE RETURNED TO THE
CONSTRUCTION SITE BY THE END OF EACH WORK
DAY AND DISPOSED IN THE MANNER DESCRIBED IN
THIS PLAN. IN NO CASE SHALL THE SEDIMENT BE
WASHED, SHOVELED, OR SWEPT INTO ANY
ROADSIDE DITCH, STORM SEWER, OR SURFACE
WATER.
18. ALL SEDIMENT REMOVED FROM BMPS SHALL BE
DISPOSED OF IN THE MANNER DESCRIBED ON THE
PLAN DRAWINGS.
19. AREAS WHICH ARE TO BE TOPSOILED SHALL BE
SCARIFIED TO A MINIMUM DEPTH OF 3 TO 5 INCHES -
6 TO 12 INCHES ON COMPACTED SOILS - PRIOR TO
PLACEMENT OF TOPSOIL. AREAS TO BE VEGETATED
SHALL HAVE A MINIMUM 4 INCHES OF TOPSOIL IN
PLACE PRIOR TO SEEDING AND MULCHING. FILL
OUTSLOPES SHALL HAVE A MINIMUM OF 2 INCHES OF
TOPSOIL.
20. ALL FILLS HALL BE COMPACTED AS REQUIRED TO
REDUCE EROSION, SLIPPAGE, SETTLEMENT,
SUBSIDENCE OR OTHER RELATED PROBLEMS. FILL
INTENDED TO SUPPORT BUILDINGS, STRUCTURES
AND CONDUITS, ETC. SHALL BE COMPACTED IN
ACCORDANCE WITH LOCAL REQUIREMENTS OR
CODES.
21. ALL EARTHEN FILLS SHALL BE PLACED IN
COMPACTED LAYERS NOT TO EXCEED 9 INCHES IN
THICKNESS.
22. FILL MATERIALS SHALL BE FREE OF FROZEN
PARTICLES, BRUSH, ROOTS, SOD, OR OTHER
FOREIGN OR OBJECTIONABLE MATERIALS THAT
WOULD INTERFERE WITH OR PREVENT
CONSTRUCTION OF SATISFACTORY FILLS.
23. FROZEN MATERIALS OR SOFT, MUCKY, OR HIGHLY
COMPRESSIBLE MATERIALS SHALL NOT BE
INCORPORATED INTO FILLS.
24. FILL SHALL NOT BE PLACED ON SATURATED OR
FROZEN SURFACES.
25. SEEPS OR SPRINGS ENCOUNTERED DURING
CONSTRUCTION SHALL BE HANDLED IN
ACCORDANCE WITH THE STANDARD AND
SPECIFICATION FOR SUBSURFACE DRAIN OR OTHER
APPROVED METHOD.
26. ALL GRADED AREAS SHALL BE PERMANENTLY
STABILIZED UPON REACHING FINISHED GRADE. CUT
SLOPES IN COMPETENT BEDROCK AND ROCK FILLS
NEED NOT BE VEGETATED. SEEDED AREAS WITHIN
50 FEET OF A SURFACE WATER, OR AS OTHERWISE
SHOWN ON THE PLAN DRAWINGS, SHALL BE
BLANKETED ACCORDING TO THE STANDARDS OF
THIS PLAN.
27. IMMEDIATELY AFTER EARTH DISTURBANCE
ACTIVITIES CEASE IN ANY AREA OR SUBAREA OF
THE PROJECT, THE OPERATOR SHALL STABILIZE ALL
DISTURBED AREAS. DURING NON-GERMINATING
MONTHS, MULCH OR PROTECTIVE BLANKETING
SHALL BE APPLIED AS DESCRIBED IN THE PLAN.
AREAS NOT AT FINISHED GRADE, WHICH WILL BE
REACTIVATED WITHIN 1 YEAR, MAY BE STABILIZED IN
ACCORDANCE WITH THE TEMPORARY STABILIZATION
SPECIFICATIONS. THOSE AREAS WHICH WILL NOT BE
REACTIVATED WITHIN 1 YEAR SHALL BE STABILIZED
IN ACCORDANCE WITH THE PERMANENT
STABILIZATION SPECIFICATIONS.
28. PERMANENT STABILIZATION IS DEFINED AS A
MINIMUM UNIFORM, PERENNIAL 70% VEGETATIVE
COVER OR OTHER PERMANENT NON-VEGETATIVE
COVER WITH A DENSITY SUFFICIENT TO RESIST
ACCELERATED EROSION. CUT AND FILL SLOPES
SHALL BE CAPABLE OF RESISTING FAILURE DUE TO
SLUMPING, SLIDING, OR OTHER MOVEMENTS.
29. E&S BMPS SHALL REMAIN FUNCTIONAL AS SUCH
UNTIL ALL AREAS TRIBUTARY TO THEM ARE
PERMANENTLY STABILIZED OR UNTIL THEY ARE
REPLACED BY ANOTHER BMP APPROVED BY THE
LOCAL CONSERVATION DISTRICT OR THE
DEPARTMENT.
30. UPON COMPLETION OF ALL EARTH DISTURBANCE
ACTIVITIES AND PERMANENT STABILIZATION OF ALL
DISTURBED AREAS, THE OWNER AND/OR OPERATOR
SHALL CONTACT THE LOCAL CONSERVATION
DISTRICT FOR AN INSPECTION PRIOR TO
REMOVAL/CONVERSION OF THE E&S BMPS.
31. AFTER FINAL SITE STABILIZATION HAS BEEN
ACHIEVED, TEMPORARY EROSION AND SEDIMENT
BMPS MUST BE REMOVED OR CONVERTED TO
PERMANENT POST CONSTRUCTION STORMWATER
MANAGEMENT BMPS. AREAS DISTURBED DURING
REMOVAL OR CONVERSION OF THE BMPS SHALL BE
STABILIZED IMMEDIATELY. IN ORDER TO ENSURE
RAPID REVEGETATION OF DISTURBED AREAS, SUCH
REMOVAL/CONVERSIONS ARE TO BE DONE ONLY
DURING THE GERMINATING SEASON.
32. UPON COMPLETION OF ALL EARTH DISTURBANCE
ACTIVITIES AND PERMANENT STABILIZATION OF ALL
DISTURBED AREAS, THE OWNER AND/OR OPERATOR
SHALL CONTACT THE LOCAL CONSERVATION
DISTRICT TO SCHEDULE A FINAL INSPECTION.
33. FAILURE TO CORRECTLY INSTALL E&S BMPS,
FAILURE TO PREVENT SEDIMENT-LADEN RUNOFF
FROM LEAVING THE CONSTRUCTION SITE, OR
FAILURE TO TAKE IMMEDIATE CORRE3CTIVE ACTION
TO RESOLVE FAILURE OF E&S BMPS MAY RESULT IN
ADMINISTRATIVE, CIVIL, AND/OR CRIMINAL
PENALTIES BEING INSTITUTED BY THE DEPARTMENT
AS DEFINED IN SECTION 602 OF THE PENNSYLVANIA
CLEAN STREAMS LAW. THE CLEAN STREAMS LAW
PROVIDES FOR UP TO $10,000 PER DAY IN CIVIL
PENALTIES, UP TO $10,000 IN SUMMARY CRIMINAL
PENALTIES, AND UP TO $25,000 IN MISDEMEANOR
CRIMINAL PENALTIES FOR EACH VIOLATION.
EROSION & SEDIMENT NARRATIVE
PROJECT DESCRIPTION
THE PURPOSE OF THIS PROJECT IS TO REPLACE
DETERIORATED SPLIT BLOCK FACING ON AN
EXISTING RETAINING WALL AND IMPROVE
DRAINAGE BETWEEN THE VISITOR CENTER
BUILDING AND THE RETAINING WALL WITH THE
INSTALLATION OF A TRENCH DRAIN SYSTEM AND
REGRADING.
A TOTAL OF APPROXIMATELY 2,265 SF OR 0.05
ACRES WILL BE DISTURBED DURING
CONSTRUCTION.
EXISTING CONDITIONS
THE FORT NECESSITY NATIONAL BATTLEFIELD
VISITOR CENTER IS LOCATED IN FARMINGTON,
PENNSYLVANIA. AN EXISTING RETAINING WALL
HAS SUFFERED DETERIORATED SPLIT BLOCK
FACING DUE TO SALT RUNOFF FROM WINTRY
CONDITIONS. AN EXISTING TOPOGRAPHIC
SURVEY HAS NOT BEEN CONDUCTED. DRAWINGS
HAVE BEEN PROVIDED FROM RECORD
INFORMATION AND THROUGH MANUAL
MEASUREMENTS MADE ON SITE.
ADJACENT PROPERTY
SOUTH: NOT APPLICABLE
NORTH: NOT APPLICABLE
EAST: NOT APPLICABLE
WEST: NOT APPLICABLE
SOILS
PER INFORMATION OBTAINED FROM THE
NATURAL RESOURCES CONSERVATION
SERVICE WEB SOIL SURVEY, THE SOILS AT THE
SITE CAN GENERALLY BE CHARACTERIZED AS
PHILO LOAM AT 0 TO 3 PERCENT SLOPES, WITH
A HYDROLOGIC SOIL GROUP OF B/D.
NO GEOTECHNICAL REPORT HAS BEEN
PROVIDED.
CRITICAL AREAS
NONE WITHIN PROJECT SCOPE.
EROSION CONTROL PROGRAM
UNLESS OTHERWISE INDICATED, ALL
VEGETATIVE AND STRUCTURAL EROSION AND
SEDIMENT CONTROL PRACTICES SHALL BE
CONSTRUCTED AND MAINTAINED IN
ACCORDANCE WITH THE EROSION AND
SEDIMENT POLLUTION CONTROL PROGRAM
MANUAL (LATEST EDITION).
STRUCTURAL PRACTICES
SILT FENCE - PROVIDE SILT FENCE FOR SHEET
FLOW AREAS AT LOCATIONS SHOWN ON
THE PLAN.
STORM INLET PROTECTION - PROVIDE STONE
INLET PROTECTION ON EXISTING DRAINS
AS SHOWN ON PLAN.
SEQUENCE OF CONSTRUCTION FOR
INSTALLATION OF EROSION AND SEDIMENT
CONTROL DEVICES
GENERAL
1. INSTALL PERIMETER EROSION AND
SEDIMENT CONTROLS.
2. INSTALL INLET PROTECTION AT
EXISTING STORM DRAIN INLETS AS
NECESSARY AND AS SHOWN ON THIS PLAN.
3. INSTALL ADDITIONAL EROSION AND
SEDIMENT CONTROL PRACTICES AS
NECESSARY.
4. CONDUCT DEMOLITION AND
CONSTRUCTION ACTIVITIES ACCORDING TO
THE APPLICABLE PLANS.
5. AS CONTRIBUTORY DRAINAGE AREAS
ARE STABILIZED AND WITH THE PERMISSION
OF THE EROSION AND SEDIMENT CONTROL
INSPECTOR, REMOVE INDIVIDUAL EROSION
AND SEDIMENT CONTROL PRACTICES.
6. UPON COMPLETION OF DEMOLITION,
CONSTRUCTION, AND LAND DISTURBING
ACTIVITIES; PROVIDE PERMANENT
STABILIZATION ACCORDING TO APPROVED
METHODS AND REMOVE ALL REMAINING
EROSION AND SEDIMENT CONTROL
MEASURES WITH THE APPROVAL OF THE
EROSION AND SEDIMENT CONTROL
INSPECTOR.
PHASE 1
1. INSTALL INLET PROTECTION AT
EXISTING STORM DRAIN INLETS AS
NECESSARY AND AS SHOWN ON THIS PLAN.
2. CLEAR FOR REMAINDER OF
PERIMETER CONTROLS.
3. INSTALL REMAINDER OF PERIMETER
AND SEDIMENT TRAPPING CONTROLS AS
SHOWN ON THE PHASE 1 PLAN INCLUDING:
* SILT FENCE
* STONE INLET PROTECTION
4. INSTALL ADDITIONAL EROSION AND
SEDIMENT CONTROL PRACTICES AS
NECESSARY.
5. WITH AUTHORIZATION FROM THE
PENNSYLVANIA DEPARTMENT OF
ENVIRONMENTAL PROTECTION EROSION
AND SEDIMENT CONTROL INSPECTOR,
CONDUCT DEMOLITION AND CONSTRUCTION
ACTIVITIES ACCORDING TO THE APPLICABLE
PLANS.
PHASE 2
1. TEMPORARY SEEDING AND MULCHING
OR OTHER STABILIZATION WILL FOLLOW
IMMEDIATELY AFTER GRADING IN AREAS NOT
UNDER ACTIVE CONSTRUCTION.
2. INSTALL STORM SEWER SYSTEM.
3. AFTER STORMWATER SYSTEM HAS
BEEN INSTALLED, INSTALL INLET
PROTECTION.
4. INSTALL ANY OTHER CONTROLS PER
THE PHASE 2 PLAN.
5. ALL EROSION AND SEDIMENT
CONTROLS ARE TO REMAIN IN PLACE FOR
THE DURATION OF THE PROJECT AND ARE
TO BE REMOVED ONLY WITH THE
CONCURRENCE OF THE PENNSYLVANIA
DEPARTMENT OF ENVIRONMENTAL
PROTECTION EROSION AND SEDIMENT
CONTROL INSPECTOR.
8. AFTER ACHIEVING ADEQUATE
STABILIZATION AND APPROVAL OF THE
PENNSYLVANIA DEPARTMENT OF
ENVIRONMENTAL PROTECTION EROSION
AND SEDIMENT CONTROL INSPECTOR, THE
TEMPORARY EROSION AND SEDIMENT
CONTROLS SHALL BE CLEANED UP AND
REMOVED. INLET PROTECTION IS TO REMAIN
IN PLACE UNTIL VEGETATION IS
ESTABLISHED. ANY BARE AREAS SHALL BE
SEEDED AND MULCHED.
PERMANENT STABILIZATION
ALL AREAS DISTURBED BY CONSTRUCTION
SHALL BE STABILIZED WITH PERMANENT
SEEDING IMMEDIATELY FOLLOWING FINISH
GRADING. SEEDING SHALL BE DONE WITH
APPROVED SEED MIXTURES FOR
PERMANENT SEEDING PER THE EROSION
AND SEDIMENT POLLUTION CONTROL
PROGRAM MANUAL. IN ALL SEEDING
OPERATIONS, SEED, FERTILIZER AND LIME
WILL BE APPLIED PRIOR TO MULCHING.
LINEAR UTILITY EROSION AND SEDIMENT
CONTROL NOTES
UNDERGROUND UTILITY LINES SHALL BE
INSTALLED IN ACCORDANCE WITH THE
FOLLOWING STANDARDS IN ADDITION TO
OTHER APPLICABLE CRITERIA:
A. NO MORE THAN 500 LINEAR FEET OF
TRENCH MAY BE OPENED AT ONE TIME.
B. EXCAVATED MATERIAL SHALL BE PLACED
ON THE UPHILL SIDE OF TRENCHES.
C. EFFLUENT FROM DEWATERING
OPERATIONS SHALL BE FILTERED OR
PASSED THROUGH AN APPROVED
SEDIMENT TRAPPING DEVICE, OR BOTH,
AND DISCHARGED IN A MANNER THAT DOES
NOT ADVERSELY AFFECT FLOWING
STREAMS OR OFF-SITE PROPERTY.
D. MATERIAL USED FOR BACKFILLING
TRENCHES SHALL BE PROPERLY
COMPACTED IN ORDER TO MINIMIZE
EROSION AND PROMOTE STABILIZATION.
E. RESTABILIZATION SHALL BE
ACCOMPLISHED IN ACCORDANCE WITH
THESE REGULATIONS.
F. APPLICABLE SAFETY REGULATIONS SHALL
BE COMPLIED WITH.
SOIL STOCKPILES
DURING CONSTRUCTION SOIL STOCKPILES AND
BORROW AREAS SHALL BE STABILIZED OR
PROTECTED WITH SEDIMENT TRAPPING
MEASURES. THE CONTRACTOR IS RESPONSIBLE
FOR THE TEMPORARY PROTECTION AND
PERMANENT STABILIZATION OF ALL SOIL
STOCKPILES ON SITE AS WELL AS BORROW
AREAS AND SOIL INTENTIONALLY
TRANSPORTED FROM THE PROJECT SITE.
5/
/2
:1
R
O N
.K
IN
G
4.
1S
(L M
S
TE
C H
) P :\2
2\
6_
N
PS
F O
N E
R W
\0 3_
D R
AW
IN
G S\
C
IV
IL
\C
ER
O
SI
O N
S
ED
IM
EN
T
C O
N
TR
O L
N O
TE
S
N
AR
R
AT
IV
E.
D
W G
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text A/E FIRM: STRUCTURAL: McMullan Consulting Engineers Reston, VA CIVIL: Sorba Engineering Dulles, VA
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text 06/09/2023
AutoCAD SHX Text
RK
AutoCAD SHX Text
RK
AutoCAD SHX Text
MM
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text 179591
AutoCAD SHX Text
PMIS/ PKG NO.
AutoCAD SHX Text 320561
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
AutoCAD SHX Text
FORT NECESSITY - NATIONAL ROAD INTERPRETIVE AND EDUCATION CENTER
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1" = 5'
AutoCAD SHX Text C6
AutoCAD SHX Text
EROSION & SEDIMENT CONTROL NOTES & NARRATIVE
AutoCAD SHX Text
RMaine Rectangle
RMaine Image
RMaine Image
RMaine Rectangle
RMaine
6/
/2
:4
SH
IM
AA
.A W
W
AD
5.
0S (L
M S
TE
C
H ) P
:\2
2\
6_ N
PS
F
O N
E R
W \0
3_ D
R
AW
IN
G
S\ C
IV
IL
\C
ER
O
SI
O
N
S
ED
IM
EN
T C
O N
TR
O
L D
ET
AI
LS
.D
W G
6/21/2024
TRENCH DRAIN DETAIL
SCALE: NTS
C7
TRENCH DRAIN GRATE SPECIFICATION
SCALE: NTS
2 TRENCH DRAIN GRATE SPECIFICATION
SCALE: NTS
C7 C7
EX COMPACTED SUBGRADE
EX CRUSHED STONE
EX DAMP PROOFING
DO NOT DAMAGE
EX 0.5' COURSE SAND
EX FILTER FABRIC
EX STORM PIPE
LOCATION TO BE
VERIFIED IN FIELD
CONCRETE SLAB ON GRADE
1.0% TO 2.0% SLOPE TO DRAIN
0.33'0.33'
1% MIN.
2% MAX.
0.43'
0.
(M
IN
0.
.9 8'
2" ISOLATION JOINT
0.
' M
IN
TRENCH
DRAIN
4000 PSI CONCRETE
WITH BROOM FINISH
WELDED WIRE FABRIC
REINFORCEMENT
COMPACTED GRADED
AGGREGATE BASE
(3 4" CRUSHED STONE)
APPROVED SUBGRADE
PROVIDE FORMED, SAWED OR
8' INTERVAL SPACING (TYP)
(5.0' X 5.0' MAX. SPACING).
PROVIDE EXPANSION JOINTS AT
FIXED OBJECTS
5" MIN.
4" MIN.
1"
CONCRETE SIDEWALK DETAIL
SCALE: NTS
C7
5/
/2
:2
R
O N
.K
IN
G
4.
1S
(L M
S
TE
C H
) P :\2
2\
6_
N
PS
F O
N E
R W
\0 3_
D R
AW
IN
G S\
C
IV
IL
\C
SI
TE
D
ET
AI
LS
.D
W G
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text A/E FIRM: STRUCTURAL: McMullan Consulting Engineers Reston, VA CIVIL: Sorba Engineering Dulles, VA
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text 06/09/2023
AutoCAD SHX Text
RK
AutoCAD SHX Text
RK
AutoCAD SHX Text
MM
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text 179591
AutoCAD SHX Text
PMIS/ PKG NO.
AutoCAD SHX Text 320561
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
AutoCAD SHX Text
FORT NECESSITY - NATIONAL ROAD INTERPRETIVE AND EDUCATION CENTER
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
AutoCAD SHX Text
SITE DETAILS
AutoCAD SHX Text
RMaine Rectangle
RMaine Image
RMaine Image
RMaine Rectangle
RMaine
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
A/E FIRM:
AutoCAD SHX Text
STRUCTURAL:
AutoCAD SHX Text
INTERPRETIVE AND EDUCATION CENTER
AutoCAD SHX Text
FORT NECESSITY - NATIONAL ROAD
AutoCAD SHX Text 06/09/2023
AutoCAD SHX Text
DB
AutoCAD SHX Text
AA
AutoCAD SHX Text
BB
AutoCAD SHX Text 179591
AutoCAD SHX Text
AutoCAD SHX Text
DESIGN NOTES
AutoCAD SHX Text 306943
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S0.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
SCALE B
AutoCAD SHX Text (1/4"=1'-0")
AutoCAD SHX Text DESIGN NOTES CODES AND STANDARDS A. WORK IN ACCORDANCE WITH REQUIREMENTS OF THE LOCAL WORK IN ACCORDANCE WITH REQUIREMENTS OF THE LOCAL BUILDING DEPARTMENT, THE PENNSYLVANIA UNIFORM STATEWIDE BUILDING CODE AND THE INTERNATIONAL BUILDING CODE, 2021. B. USE THE CURRENT VERSION OF ALL CODES, REFERENCES AND USE THE CURRENT VERSION OF ALL CODES, REFERENCES AND STANDARDS REFERRED UNLESS A DIFFERENT VERSION IS LISTED IN THE BUILDING CODE. CONCRETE AND REINFORCING A. PROVIDE CONCRETE WORK IN ACCORDANCE WITH "BUILDING PROVIDE CONCRETE WORK IN ACCORDANCE WITH "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE", ACI 318. AS MODIFIED BY IBC CODE. B. CONCRETE DESIGN IS IN ACCORDANCE WITH "STRENGTH CONCRETE DESIGN IS IN ACCORDANCE WITH "STRENGTH DESIGN METHOD." C. PROVIDE ALL CONCRETE EXPOSED TO FREEZE THAW WITH PROVIDE ALL CONCRETE EXPOSED TO FREEZE THAW WITH MINIMUM 5000 PSI WITH MAX W/C RATIO 0.40. PROVIDE CONCRETE MIX WITH ULTIMATE COMPRESSIVE STRENGTH AT 28 DAYS (F'C) ELSEWHERE: 1. SIDEWALKS AND PAVEMENTS = 5,000 PSI CLASS C SIDEWALKS AND PAVEMENTS = 5,000 PSI CLASS C CLASS C D. CONCRETE MATERIALS: CONCRETE MATERIALS: 1. CEMENT: ASTM C-150 TYPE I OR III CEMENT: ASTM C-150 TYPE I OR III ASTM C-150 TYPE I OR III 2. CEMENT SUBSTITUTES: ASTM C-595 TYPE '1P' (LIMIT TO CEMENT SUBSTITUTES: ASTM C-595 TYPE '1P' (LIMIT TO ASTM C-595 TYPE '1P' (LIMIT TO 25% MAXIMUM CEMENTITIOUS CONTENT BY WEIGHT.) 3. AGGREGATES: ASTM C-33 (NORMAL WEIGHT) AGGREGATES: ASTM C-33 (NORMAL WEIGHT) ASTM C-33 (NORMAL WEIGHT) 4. AIR-ENTRAINING ADMIX: ASTM C-260 AIR-ENTRAINING ADMIX: ASTM C-260 ASTM C-260 5. ISOLATION JOINT FILLER: ASTM D-1751 ISOLATION JOINT FILLER: ASTM D-1751 ASTM D-1751 6. JOINT SEALANT: ASTM C-920 JOINT SEALANT: ASTM C-920 ASTM C-920 E. CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED 6%, +/- 1%. F. THOROUGHLY COMPACT CONCRETE DURING PLACEMENT AND THOROUGHLY COMPACT CONCRETE DURING PLACEMENT AND WORK AROUND EMBEDDED ITEMS AND INTO CORNERS OF FORMS. G. LOCATE AND SECURE ALL ITEMS TO BE EMBEDDED IN LOCATE AND SECURE ALL ITEMS TO BE EMBEDDED IN CONCRETE. VERIFY LOCATION OF EMBEDMENT PLATES PRIOR TO CONCRETE PLACEMENT. H. SUBMIT PROPOSED CONTRACTION JOINT LAYOUT DRAWING FOR SUBMIT PROPOSED CONTRACTION JOINT LAYOUT DRAWING FOR REVIEW PRIOR TO POURING SLAB. I. KEEP HEAVY CONSTRUCTION EQUIPMENT AWAY FROM WALLS, KEEP HEAVY CONSTRUCTION EQUIPMENT AWAY FROM WALLS, DISTANCE OF WALL HEIGHT. J. PROVIDE CONCRETE SLUMP = 4" PLUS OR MINUS 1". PROVIDE CONCRETE SLUMP = 4" PLUS OR MINUS 1". K. FORM CONTRACTION JOINTS WITH AN EARLY ENTRY DRY-CUT FORM CONTRACTION JOINTS WITH AN EARLY ENTRY DRY-CUT SAW EQUIPPED WITH SHATTERPROOF ABRASIVE OR DIAMOND-RIMMED BLADES. CUT 1/8-INCH WIDE JOINTS INTO CONCRETE WHEN CUTTING ACTION WILL NOT TEAR, ABRADE, OR OTHERWISE DAMAGE SURFACE AND BEFORE CONCRETE DEVELOPS RANDOM CONTRACTION CRACKS, BUT IN NO CASE LATER THAN 4 HOURS AFTER START OF POUR. L. PROVIDE DEFORMED REINFORCING BARS #3 THRU #11 IN PROVIDE DEFORMED REINFORCING BARS #3 THRU #11 IN ACCORDANCE WITH "SPECIFICATIONS FOR DEFORMED AND PLAIN BILLET STEEL BARS FOR CONCRETE REINFORCEMENT" ASTM A-615. GRADE 60KSI. M. SUBMIT SHOP DRAWINGS FOR REINFORCEMENT TO THE COTR SUBMIT SHOP DRAWINGS FOR REINFORCEMENT TO THE COTR FOR APPROVAL. PREPARE DRAWINGS UNDER THE SUPERVISION OF A PROFESSIONAL STRUCTURAL ENGINEER REGISTERED IN THE LOCAL JURISDICTION DETAILING FABRICATING, BENDING, AND PLACING CONCRETE REINFORCEMENT. COMPLY WITH ACI 315 AND ACI DETAILING MANUAL SP-66, SHOWING BAR SCHEDULES, STIRRUP SPACING, BENT BAR DIAGRAMS, AND ARRANGEMENT OF CONCRETE REINFORCEMENT. INCLUDE SPECIAL REINFORCING REQUIRED FOR OPENINGS THROUGH CONCRETE STRUCTURES. N. PROVIDE WELDED WIRE FABRIC NOTED "WWF" IN ACCORDANCE PROVIDE WELDED WIRE FABRIC NOTED "WWF" IN ACCORDANCE WITH "STANDARD SPECIFICATION FOR STEEL WELDED WIRE REINFORCEMENT, PLAIN, FOR CONCRETE" ASTM A-1064. O. PROVIDE BARS MARKED CONTINUOUS (CONT) THAT ARE PROVIDE BARS MARKED CONTINUOUS (CONT) THAT ARE LAPPED IN ACCORDANCE WITH REQUIREMENTS FOR SPLICES AS DEFINED IN ACI 318, MINIMUM 50 BAR DIAMETERS, UNLESS INDICATED OTHERWISE. COLUMN VERTICAL REINFORCING SHALL BE SPLICED AS SHOWN IN COLUMN DETAILS. P. PROVIDE SLAB-ON-GRADE WHERE NOT OTHERWISE SHOWN AS PROVIDE SLAB-ON-GRADE WHERE NOT OTHERWISE SHOWN AS MINIMUM 5-INCHES THICK WITH WWF 6 X 6 W2.9 X W 2.9 IN TOP 1/3 OF SLAB. LAP ALL MESH EDGES A MINIMUM OF TWO (2) SQUARES. PLACE CONCRETE SLAB ON MINIMUM 2 LAYERS OF 10-MIL POLYVINYL VAPOR-RETARDER FILM, PLACED ON MINIMUM 6” OF WELL COMPACTED DRAINAGE FILL. OF WELL COMPACTED DRAINAGE FILL. Q. PROVIDE MINIMUM CONCRETE COVER BETWEEN FACE OF PROVIDE MINIMUM CONCRETE COVER BETWEEN FACE OF REINFORCING BAR AND FACE OF CONCRETE AS FOLLOWS: 1. CONCRETE CAST AGAINST EARTH = 3" CONCRETE CAST AGAINST EARTH = 3" = 3" 2. FORMED CONCRETE EXPOSED TO WEATHER OR EARTH=2" FORMED CONCRETE EXPOSED TO WEATHER OR EARTH=2" 3. FORMED CONCRETE NOT EXPOSED TO WEATHER: FORMED CONCRETE NOT EXPOSED TO WEATHER: A) SLABS AND JOISTS = 3/4" SLABS AND JOISTS = 3/4" = 3/4" B) BEAMS, COLUMNS = 1-1/2" BEAMS, COLUMNS = 1-1/2" = 1-1/2" GENERAL A. INFORMATION SHOWN REGARDING EXISTING CONDITIONS HAS INFORMATION SHOWN REGARDING EXISTING CONDITIONS HAS BEEN OBTAINED BY LIMITED VISUAL OBSERVATIONS AND/OR FROM EXISTING DRAWINGS DATED JULY 19TH/, 2002 PROVIDED BY THE OWNER. AREAS NOT VISIBLE HAVE BEEN ASSUMED TYPICAL WITH OBSERVED EXISTING CONDITIONS. B. MEASURE AND PROVIDE ALL DIMENSIONS, ELEVATIONS AND MEASURE AND PROVIDE ALL DIMENSIONS, ELEVATIONS AND CONDITIONS AT THE JOB SITE PRIOR TO CONSTRUCTION AND THE SUBMISSION OF SHOP DRAWINGS AND NOTIFY THE COTR IMMEDIATELY OF ANY DISCREPANCIES. PROVIDE VERIFICATION AND NOTIFICATION AT LEAST TWO WEEKS PRIOR TO THE START OF WORK SO THAT ANY NECESSARY CHANGES CAN BE MADE WITHOUT DELAYING THE PROJECT SCHEDULE. C. DETAILS, SECTIONS, AND NOTES SHOWN ON THESE DRAWINGS DETAILS, SECTIONS, AND NOTES SHOWN ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL AND APPLY TO SIMILAR CONDITIONS ELSEWHERE UNLESS OTHERWISE SHOWN OR NOTED. D. PROVIDE SHOP DRAWINGS SUBMITTED TO THE COTR BEARING PROVIDE SHOP DRAWINGS SUBMITTED TO THE COTR BEARING THE CONTRACTOR'S STAMP, DATE AND SIGNATURE THAT VERIFIES THAT THE DOCUMENTS HAVE BEEN REVIEWED AND CORRECTED FOR CONFORMANCE TO AND COORDINATION WITH CONTRACT DOCUMENTS. E. PROCEED WITH FABRICATION ONLY AFTER SHOP DRAWING PROCEED WITH FABRICATION ONLY AFTER SHOP DRAWING APPROVAL BY THE ENGINEER. F. DO NOT REPRODUCE ANY PORTION OF CONTRACT DOCUMENTS DO NOT REPRODUCE ANY PORTION OF CONTRACT DOCUMENTS IN THE SHOP DRAWINGS. G. SUBMIT INSPECTION REPORTS AND MATERIALS TESTING SUBMIT INSPECTION REPORTS AND MATERIALS TESTING REPORTS TO THE COTR IN A TIMELY MANNER SUCH THAT CONSTRUCTION DELAY WILL BE AVOIDED. H. MEANS AND METHODS OF CONSTRUCTION ARE THE SOLE MEANS AND METHODS OF CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. I. WHERE THE CONTRACTOR IS REQUIRED TO ENGAGE A WHERE THE CONTRACTOR IS REQUIRED TO ENGAGE A PROFESSIONAL ENGINEER TO DESIGN AND SUBMIT CALCULATIONS, AND WHERE THE PROFESSIONAL ENGINEER PREPARES THE CALCULATIONS USING A COMPUTER SOFTWARE SYSTEM, USE SOFTWARE THAT IS READILY AVAILABLE, INDUSTRY STANDARD FOR STRUCTURAL ENGINEERING IN COMMON USE. TESTING AND INSPECTION RETAIN THE SERVICES TESTING AND INSPECTION AGENCY TO PERFORM THE SERVICES SPECIFIED. A. PROVIDE SERVICES ACCORDANCE WITH REQUIREMENTS OF THE PROVIDE SERVICES ACCORDANCE WITH REQUIREMENTS OF THE LOCAL JURISDICTION AT A MINIMUM. B. FAILURE TO RETAIN A TESTING AGENCY TO PROVIDE REQUIRED FAILURE TO RETAIN A TESTING AGENCY TO PROVIDE REQUIRED SERVICES OR A FAILURE TO SUBMIT SIGNED AND SEALED REPORTS IS A NON-COMPLIANCE WITH CONTRACT DOCUMENTS. C. REMOVE AND REPLACE CONSTRUCTION CONSIDERED REMOVE AND REPLACE CONSTRUCTION CONSIDERED NON-COMPLIANT. D. ALL TESTING AND INSPECTION SHALL BE UNDER THE ALL TESTING AND INSPECTION SHALL BE UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER LICENSED TO PRACTICE IN THE LOCAL JURISDICTION. E. PROVIDE PRELIMINARY HANDWRITTEN SITE VISIT REPORTS PROVIDE PRELIMINARY HANDWRITTEN SITE VISIT REPORTS CONFIRMING VERBAL DISCUSSIONS TO THE CONTRACTOR REGARDING THE RESULTS OF INSPECTIONS PRIOR TO LEAVING JOB SITE. F. SUBMIT FINAL REPORTS TO THE COTR IN A TIMELY MANNER, SUBMIT FINAL REPORTS TO THE COTR IN A TIMELY MANNER, BUT NO LATER THAN TEN (10) DAYS FOLLOWING INSPECTION OR TESTING UNDER THE NAME AND SIGNATURE OF THE INSPECTOR AND LICENSURE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER RESPONSIBLE FOR TESTING AND INSPECTION. G. PROVIDE INSPECTION FOR THE FOLLOWING AT A MINIMUM: PROVIDE INSPECTION FOR THE FOLLOWING AT A MINIMUM: 1. FOUNDATIONS & EARTHWORK: SLAB SUB-GRADE, FOUNDATIONS & EARTHWORK: SLAB SUB-GRADE, PERIMETER AND UNDERFLOOR DRAINAGE SYSTEMS. 2. REINFORCING: LOCATION, ASTM DESIGNATION, BAR SIZES, REINFORCING: LOCATION, ASTM DESIGNATION, BAR SIZES, TYPE PLAIN, QUANTITY, PLACEMENT, SPACING, AND CLEARANCES. 3. CONCRETE: ALL STRUCTURAL CONCRETE; LOCATION, CONCRETE: ALL STRUCTURAL CONCRETE; LOCATION, STRENGTH, TYPE (NORMAL OR LIGHTWEIGHT), SLUMP, PLACEMENT, AIR TEMPERATURE, CURING AND WEATHER ACCOMMODATIONS AND CONCRETE ADDITIVES. H. PROVIDE MATERIAL TESTING THE FOLLOWING: PROVIDE MATERIAL TESTING THE FOLLOWING: 1. FOUNDATION & EARTHWORK: SOIL BEARING CAPACITIES FOUNDATION & EARTHWORK: SOIL BEARING CAPACITIES AND COMPACTION DENSITIES. 2. REINFORCING: YIELD AND ULTIMATE STRENGTHS. (MILL REINFORCING: YIELD AND ULTIMATE STRENGTHS. (MILL REPORTS ARE ACCEPTABLE.) 3. CONCRETE: SLUMP TESTS; EVERY THIRD TRUCKLOAD OF CONCRETE: SLUMP TESTS; EVERY THIRD TRUCKLOAD OF CONCRETE AND IN ADDITION, ONE FOR EACH SET OF STRENGTH-TEST CYLINDERS AT PREPARATION. STRENGTH TESTS; ONE SET OF CYLINDERS FOR MAXIMUM OF EACH 50 CY OF CONCRETE PLACEMENT. ONE SET OF CYLINDERS FOR EACH 2500 SQUARE SLAB AREA. I. COMPLY WITH CODE REQUIREMENTS AND THE FOLLOWING COMPLY WITH CODE REQUIREMENTS AND THE FOLLOWING 1. CONCRETE CYLINDERS: THREE SETS OF THREE CONCRETE CYLINDERS: THREE SETS OF THREE LABORATORY CURED 4X8 CYLINDERS SHALL BE TAKEN FOR EACH DAY'S POUR FOR EACH MIX: (3) 7-DAY, (3) 28-DAY, (3) HOLD; 2. TWO SETS OF THREE FIELD CURED 4X8 CYLINDERS SHALL TWO SETS OF THREE FIELD CURED 4X8 CYLINDERS SHALL BE TAKEN FOR EACH DAY'S POUR FOR EACH MIX (3) 7 -DAY, (3) 28-DAY. J. FIELD CURED CYLINDERS SHALL BE CURED IN ACCORDANCE FIELD CURED CYLINDERS SHALL BE CURED IN ACCORDANCE WITH CODE REQUIREMENTS OR IF NOT APPLICABLE THEN CURED IN SAME CONDITIONS AS CONCRETE IN WORK. K. PROVIDE ONE SET OF MORTAR CUBES FOR COMPRESSIVE PROVIDE ONE SET OF MORTAR CUBES FOR COMPRESSIVE STRENGTH TESTING S IN ACCORDANCE WITH ASTM C91 AND C270 AT A FREQUENCY OF ONE TEST PER WEEK. L. CONDUCT MASONRY PRISM TESTS IN CONFORMANCE WITH CONDUCT MASONRY PRISM TESTS IN CONFORMANCE WITH ASTM E447 METHOD B AT A FREQUENCY OF ONE TEST PER WEEK.
RMaine Image
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
EXISTING
CONCRETE
SIDEWALK
I
I
I
I
I
I
I
I
I
I �z:::z:::::z:::::::2�-----1
TRENCH DRAIN -
PER CIVIL
DWGS, TYP.
I
I
I
I
I
I
I
I :::::::::::.
--- SAW CUT AND REMOVE
EXISTING CONCRETE SLAB ON
GRADE. REPLACE SLAB ON
GRADE PER DETAIL 2&3/S2.0
I ...................... . -------1 EXISTING k---
REMOVE EXISTING---
HSS GATE POST (2
LOCATIONS) I
I
EXISTING CONCRETE I
RETAINING WALL WITH ISPLIT FACE CMU
I VENEER AND CAP
I
I
I
I
I
I
I
I . . . . . L . . . . . ·I . . . . . ·I . . . . . t
___,,..... CONTRACTION
JOINT, TYP.
. . . . . ·I . . . . . ·I ·····t····· r
· · · · · ·L·:...:....:· · · ·.:....:..._·:...:....:.· · · ·.:....:....:· ·
BUILDING
EXISTING SLAB ON
GRADE TO REMAIN
L _______ _ KEY NOTE: --------� ----------...---... EXISTING WALL �4......_ -�� INDICATES CONCRETE SLAB ON
1.·::.·:::.·.·I GRADE REMOVAL AND REPLACEMENT.
tZ2Zl/1 INDICATES CMU BLOCK REMOVAL
.__L.,._,__..__._._._ AND REPLACEMENT W/STONE.
FOOTING TO REMAIN S2.0
1 EXISTING SEAT WALL PLAN
S1 .0 SCALE B
EXISTING BUILDING
ISOLATION JOINT
EXISTING
BUILDING
COLUMN.
DO NOT
DAMAGE
EXISTING
CONCRETE
SIDEWALK
ttl';:::z::;j
I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I . . . . . . . . . . . . . . . . . . . .............. •....:J
_________ __J
EXISTING PIPE
RAILING
2 BASIS OF DESIGN IF USING STONE VENEER
S1 .0 SCALE NTS
NOTES:
1. STONE VENEER RETAINING WALL OBSERVED AT MT
WASHINGTON TAVERN.
2. STONE PATTERN OF VENEER TO MATCH SIZE,
SHAPE AND PATTERN OF MT WASHINGTON TAVERN
RETAINING WALL WITH 4" THICKNESS. STONE COLOR
TO COMPLIMENT EXISTING CONCRETE CAPS AND
EXISTING CMU VENEER OF INTERPRETATIVE CENTER.
3. PROVIDE SAMPLE SET OF NEW STONE THAT IS A
MINIMUM OF 8"x8"x2" FOR CO REVIEW AND
APPROVAL. SAMPLE SET SHALL SHOW THE FULL
RANGE OF COLOR, GRADE, TEXTURE AND FINISH.
EXISTING
PLAYGROUND
SURFACE
A/E FIRM:
STRUCTURAL:
11!00hmt\'...,.O,_S,,,asi
R.-.o\Vo :,:i,,i
REMOVE PLAYGROUND
SURFACE PER CIVIL
DRAWINGS
EXISTING STORM DRAIN
EXISTING LANDSCAPE
BLOCK WALL
DESIGNED: SUB SHEET NO.
BB
M
TECH. REVIEW:
DB S1 .0
DATE:
06/09/2023
4 0 r-...------
4 SCALE B
(1/4"=1 '-0") SCALE OF FEET
TITLE OF SHEET
RETAINING WALL
NEW WORK PLAN
FORT NECESSITY - NATIONAL ROAD
INTERPRETIVE AND EDUCATION CENTER
I
DRAWING NO.
179591
PMIS/PKG NO.
306943
SHEET
1OoF12
BASIS OF DESIGN IF USING SPLIT FACE CMU
I. Replace existing CMU fascia block with matching 4x8x16 split face block as marked in drawing.
2. Provide sample of mating block for approval before begining instilation.
3. Replace additional CMU block, in unmarked areas on an
"as needed" basis. Min of 1 at NE corner of building, and up to a total of 5.
4. Clean existing block on outside of retaining wall walkway and re-point mortor joints as needed.
5. Apply appropriate sealant to all new and cleaned existing CMU on retaining wall, and bottom course of building CMU (below metal termite shield).
(SEE SI.0A)
AutoCAD SHX Text
EXISTING CONCRETE RETAINING WALL WITH SPLIT FACE CMU VENEER AND CAP
AutoCAD SHX Text
EXISTING BUILDING
AutoCAD SHX Text
EXISTING CONCRETE SIDEWALK
AutoCAD SHX Text
EXISTING CONCRETE SIDEWALK
AutoCAD SHX Text
EXISTING LANDSCAPE BLOCK WALL
AutoCAD SHX Text
EXISTING PIPE RAILING
AutoCAD SHX Text
EXISTING STORM DRAIN
AutoCAD SHX Text
EXISTING BUILDING COLUMN. DO NOT DAMAGE
AutoCAD SHX Text
EXISTING BUILDING ISOLATION JOINT
AutoCAD SHX Text
CONTRACTION JOINT, TYP.
AutoCAD SHX Text
REMOVE EXISTING HSS GATE POST (2 LOCATIONS)
AutoCAD SHX Text SAW CUT AND REMOVE EXISTING CONCRETE SLAB ON GRADE. REPLACE SLAB ON GRADE PER DETAIL 2&3/S2.0
AutoCAD SHX Text
AutoCAD SHX Text S2.0
AutoCAD SHX Text S2.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S2.0
AutoCAD SHX Text
EXISTING PLAYGROUND SURFACE
AutoCAD SHX Text S2.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S2.0
AutoCAD SHX Text
EXISTING WALL FOOTING TO REMAIN
AutoCAD SHX Text
EXISTING SLAB ON GRADE TO REMAIN
AutoCAD SHX Text
REMOVE PLAYGROUND SURFACE PER CIVIL DRAWINGS
AutoCAD SHX Text
TRENCH DRAIN PER CIVIL DWGS, TYP.
AutoCAD SHX Text
AutoCAD SHX Text S2.0
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
A/E FIRM:
AutoCAD SHX Text
STRUCTURAL:
AutoCAD SHX Text
INTERPRETIVE AND EDUCATION CENTER
AutoCAD SHX Text
FORT NECESSITY - NATIONAL ROAD
AutoCAD SHX Text 06/09/2023
AutoCAD SHX Text
DB
AutoCAD SHX Text
AA
AutoCAD SHX Text
BB
AutoCAD SHX Text 179591
AutoCAD SHX Text
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text %%u EXISTING SEAT WALL PLAN
AutoCAD SHX Text S1.0
AutoCAD SHX Text B
AutoCAD SHX Text
NEW WORK PLAN
AutoCAD SHX Text
RETAINING WALL
AutoCAD SHX Text 306943
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
SCALE B
AutoCAD SHX Text (1/4"=1'-0")
AutoCAD SHX Text KEY NOTE: INDICATES CONCRETE SLAB ON GRADE REMOVAL AND REPLACEMENT. INDICATES CMU BLOCK REMOVAL AND REPLACEMENT W/STONE.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
%%U BASIS OF DESIGN FOR STONE VENEER
AutoCAD SHX Text
NTS
NOTES: 1. STONE VENEER RETAINING WALL OBSERVED AT MT STONE VENEER RETAINING WALL OBSERVED AT MT WASHINGTON TAVERN. 2. STONE PATTERN OF VENEER TO MATCH SIZE, STONE PATTERN OF VENEER TO MATCH SIZE, SHAPE AND PATTERN OF MT WASHINGTON TAVERN RETAINING WALL WITH 4" THICKNESS. STONE COLOR TO COMPLIMENT EXISTING CONCRETE CAPS AND EXISTING CMU VENEER OF INTERPRETATIVE CENTER. 3. PROVIDE SAMPLE SET OF NEW STONE THAT IS A PROVIDE SAMPLE SET OF NEW STONE THAT IS A MINIMUM OF 8"x8"x2" FOR CO REVIEW AND APPROVAL. SAMPLE SET SHALL SHOW THE FULL RANGE OF COLOR, GRADE, TEXTURE AND FINISH.
XXXX
CMU
1. Replace existing CMU fascia block with matching 4x8x16 split face block as marked in drawing.
2. Provide sample of mating block for approval before begining instilation.
3. Replace additional CMU block, in unmarked areas on an "as needed" basis. Min of 1 at NE corner of building, and up to a total of 5.
4. Clean existing block on outside of retaining wall walkway and re-point mortor joints as needed.
5. Apply appropriate sealent to all new and cleaned existing CMU on retaining wall, and bottom course of building CMU (below metal termite shield.
xx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X x x xx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Xx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
X
X weave new block into existing block x x x x AXXXX
FOR CMU
XXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXX
AutoCAD SHX Text
EXISTING CONCRETE RETAINING WALL WITH SPLIT FACE CMU VENEER AND CAP
AutoCAD SHX Text
EXISTING BUILDING
AutoCAD SHX Text
EXISTING CONCRETE SIDEWALK
AutoCAD SHX Text
EXISTING CONCRETE SIDEWALK
AutoCAD SHX Text
EXISTING LANDSCAPE BLOCK WALL
AutoCAD SHX Text
EXISTING PIPE RAILING
AutoCAD SHX Text
EXISTING STORM DRAIN
AutoCAD SHX Text
EXISTING BUILDING COLUMN. DO NOT DAMAGE
AutoCAD SHX Text
EXISTING BUILDING ISOLATION JOINT
AutoCAD SHX Text
CONTRACTION JOINT, TYP.
AutoCAD SHX Text
REMOVE EXISTING HSS GATE POST (2 LOCATIONS)
AutoCAD SHX Text SAW CUT AND REMOVE EXISTING CONCRETE SLAB ON GRADE. REPLACE SLAB ON GRADE PER DETAIL 2&3/S2.0
AutoCAD SHX Text
AutoCAD SHX Text S2.0
AutoCAD SHX Text S2.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S2.0
AutoCAD SHX Text
EXISTING PLAYGROUND SURFACE
AutoCAD SHX Text S2.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S2.0
AutoCAD SHX Text
EXISTING WALL FOOTING TO REMAIN
AutoCAD SHX Text
EXISTING SLAB ON GRADE TO REMAIN
AutoCAD SHX Text
REMOVE PLAYGROUND SURFACE PER CIVIL DRAWINGS
AutoCAD SHX Text
TRENCH DRAIN PER CIVIL DWGS, TYP.
AutoCAD SHX Text
AutoCAD SHX Text S2.0
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
A/E FIRM:
AutoCAD SHX Text
STRUCTURAL:
AutoCAD SHX Text
INTERPRETIVE AND EDUCATION CENTER
AutoCAD SHX Text
FORT NECESSITY - NATIONAL ROAD
AutoCAD SHX Text 06/09/2023
AutoCAD SHX Text
DB
AutoCAD SHX Text
AA
AutoCAD SHX Text
BB
AutoCAD SHX Text 179591
AutoCAD SHX Text
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text %%u EXISTING SEAT WALL PLAN
AutoCAD SHX Text S1.0
AutoCAD SHX Text B
AutoCAD SHX Text
NEW WORK PLAN
AutoCAD SHX Text
RETAINING WALL
AutoCAD SHX Text 306943
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
SCALE B
AutoCAD SHX Text (1/4"=1'-0")
AutoCAD SHX Text KEY NOTE: INDICATES CONCRETE SLAB ON GRADE REMOVAL AND REPLACEMENT. INDICATES CMU BLOCK REMOVAL AND REPLACEMENT W/STONE.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
%%U BASIS OF DESIGN FOR STONE VENEER
AutoCAD SHX Text
NTS
NOTES: 1. STONE VENEER RETAINING WALL OBSERVED AT MT STONE VENEER RETAINING WALL OBSERVED AT MT WASHINGTON TAVERN. 2. STONE PATTERN OF VENEER TO MATCH SIZE, STONE PATTERN OF VENEER TO MATCH SIZE, SHAPE AND PATTERN OF MT WASHINGTON TAVERN RETAINING WALL WITH 4" THICKNESS. STONE COLOR TO COMPLIMENT EXISTING CONCRETE CAPS AND EXISTING CMU VENEER OF INTERPRETATIVE CENTER. 3. PROVIDE SAMPLE SET OF NEW STONE THAT IS A PROVIDE SAMPLE SET OF NEW STONE THAT IS A MINIMUM OF 8"x8"x2" FOR CO REVIEW AND APPROVAL. SAMPLE SET SHALL SHOW THE FULL RANGE OF COLOR, GRADE, TEXTURE AND FINISH.
REPLACE SPLIT FACE CMU --
VENEER PER NOTE 1
TEMP REMOVE EX. ---
RECESSED WALL LIGHT
�" WITH BACKER ROD �--..,
AND SEALANT AT THE
TOP ISOLATION JOINT
FACE OF
EX. BUILD
CONCRETE S B ON GRADE
W/ 6x6 W2.9xW2.9 IN TOP
! OF SLAB. TOP SLOPED TO
DRAIN PER CIVIL
TRENCH DRAIN PER --
CIVIL DWGS
EX. COMPACTED --
SUBGRADE
EX. 3/4" CRUSHED -
STONE
EX. DAMP PROOFING -
DO NOT DAMAGE
EX. 6" COURSE SAND --
I!)
2' -0"
.. . •: . .. .. : . . .. .. : . ... "i . .
:- • • 'IIQI
r.s...,.��J1�· • :"
1 '-0"
1--cn:r:w c.,- a:::
W<( :r:>
1 '-6"
-- AS NEEDED
TEMP REMOVE EX. WALL CAP
AND RESET IN BED OF MORTAR
AFTER COMPLETIOJ\ OF WORK.
IF REMOVED OR NOT, REPLACE ALL
WALL CAP SEAM SEALANT
i--- REMOVE EXISTING
DETERIORATED SPLIT
FACE CMU AND
REPLACE PER NOTE 1
ASSUMED LIMITS
OF EXCAVATION
co r<")
EX. FILTER FABRIC-==---
�'.•�...,:"'"'.·�-··4. �
<t
���- •.EX. PERFORATED PIPE .,/ ..
� ... ·• •. �. ,·.�•·::�:-' ••·,,.�·:•.:· .. _ .:_,._. SHELF ELEVATION MAY
--------t'=·=· ·.
: VARY FIELD VERIFY
EX. CONCRETE ·• • ' • .., • � • • • • • ___ ..,._ AND NOTIFY COR OF
FOOTING L VARIES L AND DIFFERENCES
� n
@ RETA&HNG WALL W/SPLII FACE CMU VENEER AROUND PATIO
S2.0 SCALE E
TEMP REMOVE EX. ---..
RECESSED WALL LIGHT
2' -0" f' ISOLATION JOINT
CONCRETE SLAB ON
GRADE W/ 6x6 W2.9xW2.9 IN TOP !
OF SLAB. TOP 1 '-0"
SLOPED TO DRAIN �M1!)1N��3����r.41L�t:.�11a....:...___::..._PER CIVIL
SHELF ELEVATION MAY
VARY. FIELD VERIFY
AND NOTIFY COR OF
AND DIFFERENCES
EX. COMPACTED -
2· -0"
AS NEEDED
TEMP REMOVE EX. WALL CAP AND
RESET IN BED OF MORTAR AFTER
COMPLETION OF WORK
49.34 �
FINISHED GRADE
ASSUMED LIMITS
OF EXCAVATION
RE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .