Generac Mobile Products LLC l 800-926-9768 l 920-361-4442 l www.generacmobileproducts.com
MMG25IF4
ENGINE
• Isuzu® 4LE2TAGV-03 - turbocharged, aftercooled diesel engine o Prime – 36.2 hp, 27.0kWm @ 1800 rpm o Standby – 41.2 hp, 30.0 kWm @ 1800 rpm o 4 cylinder o 2.2 L displacement o EPA Final Tier 4 approved o *Engine and generator performance are dependent upon 70 hours of break in.
• Polyethylene, single wall fuel tank o 100 gal. (378.5 L) capacity o 42.9 hr. run time – full load o Fuel tank built into skid of generator set o 120% Containment
• Cooling system capable of operating at 120°F (49°C) ambient
• Radiator and oil drains plumbed to exterior
• Rubber vibration dampers isolate engine/generator from frame
• Disposable air filter - paper element
• Air cleaner restriction indicator
• 60 Hz engine/generator
• Electronic isochronous governing
• Idle switch
GENERATOR
• Marathon Electric® SUPERSTART™ o Brushless o 4 pole o Class H insulation
• Voltage regulation +/- 0.5% with Magnum PM600 Voltage Regulator
SYSTEM OUTPUTS
• 3 position selector switch o Single phase – 120 / 240V Zig Zag o Three phase – 120 / 208V Low Wye o Three phase – 277 / 480V High Wye
• 22 kW / 22 kVA – standby, single phase
• 20 kW / 20 kVA – prime, single phase
• 23 kW / 29 kVA – standby, three phase
• 21 kW / 26 kVA – prime, three phase
SPECIFICATIONS
MOBILE DIESEL GENERATOR
MMG25IF4 MOBILE DIESEL GENERATOR
SYSTEM CONTROLS
• Power Zone® controller and display o Backlit, 800 x 480 pixel resolution color display o -40°F to 185°F (-40°C to 85°C) operating temperature range o Automatic coarse voltage adjustment o Integrated fine voltage adjustment o PLC functionality
• Push buttons for easy operation o Manual or Auto Start o Engine Start o Engine Stop/Reset o Alarm Mute o Operator Screens
Home Engine Generator Voltage Adjust o Scrolling Arrows for Diagnostic Information Engine diagnostic display
• Oil pressure
• Engine temperature
• Fuel level
• Battery
• After treatment inlet/outlet temperature
• Ash/soot levels
Generator diagnostic display
• System kW output display
• Line output & frequency display
Alarms
• Warning
• Shutdown
• Electrical Trip
• Engine
Alarm list – warnings / shutdowns; 250 event history log – date/time stamp
• Fuel level: warning – 15%; shutdown – 5%
• Over speed protection: shutdown – 115%
• Oil pressure: warning – 25 psi; shutdown – 20 psi
• Coolant temperature: warning – 220°F (104°C); shutdown – 230°F (110°C)
• Battery voltage: over – 15VDC; under – 11VDC
• Generator over voltage: warning – 110%; electrical trip – 111%
• Generator under voltage: warning – 87%; electrical trip – 86%
• Generator over frequency: warning – 105%; electrical trip – 110%
• Generator under frequency: warning – 95%; electrical trip – 90%
MMG25IF4 MOBILE DIESEL GENERATOR
SYSTEM CONTROLS (continued) Inputs/Outputs Auto Schedule Status
• Configuration of controller, firmware and connections
ELECTRICAL CONTROLS
• Remote start / stop contacts located in lug box
• Lockable control box door with diagnostics window
• Lockable lug box with safety switch o Trips main breaker when door is opened o Disables voltage regulator
• Output ground connection lug inside lug box
• 125A main breaker with shunt trip
• Convenience receptacles with individual breakers (restricted use in high wye mode) o (2) 120V 20 Amp GFCI duplex outlets – (NEMA 5-20R type) o (3) 125 / 250V 50 Amp, 3 pole, 4 wire Twistlock (Non-NEMA 6369)
• Voltage adjustment integrated into Power Zone controller, +/- 10%
• 720 CCA wet cell battery
• Battery disconnect
• Panel lighting for breakers, lugs, and selector switch
ENCLOSURE
• Aluminum, sound attenuated enclosure o UV & fade resistant, high temperature cured, white polyester powder paint o Insulated and baffled o 66 dB(A) @ 23 ft. (7 m) – prime power
• Fully lockable enclosure including doors and fuel fill
• Emergency stop switch located on outside of enclosure
• Central lifting point
• Multi-lingual operating/safety decals
• Document holder with operating manual including AC/DC wiring diagrams
• Interior Cabinet lighting
TRAILER
• DOT approved tail, side, brake, and directional lights - LED
• Transportation tie downs
• Safety chains with spring loaded safety hooks
• 2 in. (50.8 mm) ball hitch
• 5000 lb. (2268 kg) axle
• 2000 lb. (907 kg) tongue jack with footplate
• P225/75 R15 tubeless tires – 6 ply
MMG25IF4 MOBILE DIESEL GENERATOR
WEIGHT & DIMENSIONS
• Skid mounted o Dry weight: 2430 lbs (1102 kg) o Operating weight: 3160 lbs (1433 kg) o 95 x 39 x 65 in (2.41 x 0.99 x 1.65 m)
• Trailer mounted o Dry weight: 2950 lbs (1338 kg) o Operating weight: 3680 lbs (1669 kg) o 152 x 58 x 83 in (3.81 x 1.45 x 2.11 m)
WARRANTY
2 Years / 2000 Hours
CERTIFICATIONS
CSA Certified