DO34_Huckleberry_Update_Final_CD_Rev_1_Drawings_063021.pdf
PDF 2 MB Posted
- Attached to
- HUCKLEBERRY CAMPGROUND ELECTRICALUPGRADE Federal contract opportunity
- Solicitation number
- 140L2621Q0051
About this file
This document package includes electrical drawings and specifications for upgrades to the electrical system at the Huckleberry Campground, as well as details of a related federal contract opportunity posted on SAM.gov. The drawings show the existing electrical infrastructure and plans for upgrades, including new panels, transformers, conductors, and pedestals to serve additional recreational vehicle sites. The federal contract opportunity is solicitation number 140L2621Q0051 issued by the Department of the Interior Bureau of Land Management Idaho Region. It seeks bids for electrical upgrades at the Huckleberry Campground to improve the electrical system per the specifications and drawings provided. The response due date and award date are not specified. Pricing and payment terms are also not included.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140L2621Q0051_Amd_0001.pdf | ||
| 70048_034_Huckleberry_Final_Design_REV1_E201_20210818_0001.pdf | ||
| Photos_20210510_3_0001.pdf | ||
| Prebid_meeting_tjs_20210816_0001.pdf | ||
| DO34_Huckleberry_Update_Final_CD_Rev_1_Specs_063021.pdf | ||
| Sol_140L2621Q0051.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ben L Carter Digitally signed by Ben L Carter Date: 2021.06.24 12:42:39 -06'00'
Ben L Carter Digitally signed by Ben L Carter Date: 2021.06.24 12:43:09 -06'00'
H
IG
H W
AY
HIGHWAY
ST. JOE RIVER
Darrell Dean Digitally signed by Darrell Dean Date: 2021.06.24 17:07:02 -04'00'
Date: 2021.06.24 17:07:20 -04'00'
H
IG
H W
AY
HIGHWAY
ST. JOE RIVER
Darrell Dean Digitally signed by Darrell Dean Date: 2021.06.24 17:07:36 -04'00'
ST. JOE RIVER
Darrell Dean Digitally signed by Darrell Dean Date: 2021.06.24 17:07:51
Darrell Dean Digitally signed by Darrell Dean Date: 2021.06.24 17:08:05
Date: 2021.06.24 17:08:27 -04'00'
Date: 2021.06.24 17:08:43 -04'00'
NOTES:
1. PROVIDE ALL NEW BREAKERS (FEEDER AND BRACH)
FOR ALL RV PADS AND PANELS. INCLUDE PRICE
WITHIN OPTION BIDS.
2. ALL RV PEDESTAL CONDUCTORS SHALL BE
ALUMINUM.
240V
600V
A
EXISTING
100A
DISCONNECT
A
A
F
U S
E
600V
120/240V
75 kVA, NEMA 4
SITE 17
SITE 18
SITE 19
SITE 20
SITE 34
SITE 35
SITE 36
SITE 37
SITE 38
SITE 39
A
S
E
SITE 10
NEW PANEL 'E3'
240V, 400A 3W, 1PH, 42CKS
NEMA 4
SITE 11
SITE 12
SITE 13
SITE 14
SITE 15
SITE 16
A
S
E
SITE 4
PANEL 'E1'
(EXISTING)
SITE 1
SITE 2
SITE 3
SITE 5
SITE 6
PANEL 'E2'
(EXISTING,
MOVED TO NEW
PUMP HOUSE
WALL)
SITE 7
SITE 8
SITE 9
167 kVA
TO PUMP HOUSE
A
N E
W
A
N E
W
A
N E
W
A
14.4kV
120/240V
167 kVA
A
S
E
SITE 30
NEW PANEL 'W1'
240V, 400A 3W, 1PH, 42CKS
NEMA 4
SITE 31
SITE 32
SITE 33
N E
W
A
75 kVA, NEMA 4
50A
50A
NEW PANEL 'W2'
240V, 400A, 3W, 1PH, 42CKS
NEMA 4
50A
50A
600V
120/240V
50A
50A
50A
50A
50A
50A
PROVIDED BY UTILITY
PROVIDED BY CONTRACTOR
200A, 175A FUSE
600V
120/240V
50 kVA, NEMA 4
600V
120/240V
50 kVA, NEMA 4
DSW-5A
D S
W
D S
W
D S
W
D S
W
D S
W
NEW 'TF-5'
NEW 'TF-4'
NEW 'TF-3' NEW 'TF-2'
TF-1
CT
CABINET
METER BASE,
METER PROVIDED
BY UTILITY
Scale: NTS
E601
ONE-LINE DIAGRAM
SYMBOL
EXISTING CONDUCTOR/COMPONENT
NEW CONDUCTOR/COMPONENT
FUSED DISCONNECT SWITCH
TRANSFORMER
BREAKER
50/30/20 AMP COMBINATION PEDESTAL
ONE LINE DEVICES
SWITCH
JUNCTION BOX
CURRENT TRANSFORMER
TRANSFORMER
ABBREVIATIONS
SW
JB
CT
TF
3-#4 & 1-#6 GND
3-#3 & 1-#6 GND
ELECTRICAL TRANSFORMER SCHEDULE
ITEM
NO.
SIZE
(KVA)
DESCRIPTION VOLTAGE
TF-1 167 PAD MOUNTED TRANSFORMER W/ NEMA 4 ENCLOSURE 240/600
TF-2 50 PAD MOUNTED TRANSFORMER W/ NEMA 4 ENCLOSURE 600/240
TF-3 50 PAD MOUNTED TRANSFORMER W/ NEMA 4 ENCLOSURE 600/240
TF-4 75 PAD MOUNTED TRANSFORMER W/ NEMA 4 ENCLOSURE 600/240
TF-5 75 PAD MOUNTED TRANSFORMER W/ NEMA 4 ENCLOSURE 600/240
200A, 125A FUSE
DSW-2A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
SITE 21
SITE 22
SITE 23
50A
50A
50A
50A
50A
50A
SITE 24
SITE 25
SITE 26
SITE 27
SITE 28
SITE 29
3-#3 & 1-#6 GND
3-#2 & 1-#6 GND
3-#1 & 1-#6 GND
3-#1 & 1-#6 GND
3-#3 & 1-#6 GND
3-#6 & 1-#6 GND
3-#3 & 1-#6 GND
3-#2 & 1-#6 GND
3-#1/0 & 1-#6 GND
3-#1 & 1-#6 GND
3-#2 & 1-#6 GND
3-#3 & 1-#6 GND
3-#4 & 1-#6 GND
3-#3 & 1-#6 GND
3-#4 & 1-#6 GND
3-#1 & 1-#6 GND
3-#2 & 1-#6 GND
3-#4 & 1-#6 GND
REUSE EXISTING
REUSE EXISTING
REUSE EXISTING
REUSE EXISTING
REUSE EXISTING
REUSE EXISTING
3-#3/0 & 1-#4 GND
3-#1 & 1-#6 GND
3-#2 & 1-#6 GND
3-#6 & 1-#6 GND
3-#6 & 1-#6 GND
3-#3 & 1-#6 GND
3-#2 & 1-#6 GND
3-#1 & 1-#6 GND
3-#1 & 1-#6 GND
3-#1/0 & 1-#6 GND
3-#2/0 & 1-#4 GND
3-#2/0 & 1-#4 GND
3-#2/0 & 1-#4 GND
200A, 175A FUSE
DSW-4A
3-#350 MCM AL & 1-#2 GND AL
6-#250 MCM AL & 2-#1 GND AL
3-#350 MCM AL & 1-#2 GND AL
3-#250 MCM AL & 1-#4 GND AL
2-#600 MCM AL & 1-#2/0 GND AL
2-#300 MCM AL & 1-#2 GND AL
2-#2/0 AWG AL & 1-#1 GND AL
2-#2/0 AWG AL & 1-#4 AWG GND AL
3-#3/0 AL & 1-#4 GND AL
8-#30 MCM AL & 4-#3/0 GND AL
200A, 125A FUSE
DSW-3A
OPTION 1
OPTION 2
OPTION 3
OPTION 4
BASE IMPROVEMENTS
P
R
O
F
E
S
S
I
O
N
AL
E
N
G
I
N
E
E
R
D
A
R
R
L L
D
A
N
L
I
C
E N
S
E
D
S
T
A
T
OF
I
D
A
H
O
19543
AutoCAD SHX Text
CHK'D BY:
AutoCAD SHX Text
DESIGN OFFICE:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
MARK
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
UNITED STATES DEPARTMENT OF THE INTERIOR
AutoCAD SHX Text
BUREAU OF LAND MANAGEMENT
AutoCAD SHX Text PLOT DATE:6/24/2021 9:08 AM PLOTTED BY:Alfredo Rico 6/24/2021 9:08 AM PLOTTED BY:Alfredo Rico PLOTTED BY:Alfredo Rico Alfredo Rico Q:\Idaho Falls\Engineering Division\70048 BLM AE IDIQ\034 Huckleberry Campground Elec Update\Design Activities\2.0 Drawings\2.1 Dwg\2.1.2 Current\E-601
AutoCAD SHX Text
ELECTRICAL ONE-LINE DIAGRAM
AutoCAD SHX Text
HUCKLEBERRY CAMPGROUND ELECTRICAL UPGRADES
AutoCAD SHX Text
COEUR D' ALENE DISTRICT
AutoCAD SHX Text
IDAHO
AutoCAD SHX Text 70048-034
AutoCAD SHX Text
NORTH WIND IDAHO FALLS
AutoCAD SHX Text
CS
AutoCAD SHX Text
CS
AutoCAD SHX Text
DD
AutoCAD SHX Text
BC
AutoCAD SHX Text 06/24/2021
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E601
NOTES:
1. SEE SHEET E601 FOR NEW SINGLE LINE.
240V
600V
0A
100A
A
600V
120/240V 25 kVA
SITE 17
SITE 18
SITE 19
SITE 20
SITE 34
SITE 35
SITE 36
SITE 37
SITE 38
SITE 39
A
SITE 10
PANEL 'E3'
SITE 11
SITE 12
SITE 13
SITE 14
SITE 15
SITE 16
A
SITE 4
PANEL 'E1'
SITE 1
SITE 2
SITE 3
SITE 5
SITE 6
PANEL 'E2'
SITE 7
SITE 8
SITE 9
75 kVA
TO PUMP HOUSE
0A
0A
0A
0A
14.4kV
120/240V 67 kVA
A
SITE 30
PANEL 'W1'
SITE 31
SITE 32
SITE 33
0A
25 kVA
50A
PANEL 'W2'
600V
120/240V
50A
50A
50A
50A
50A
50A600V
120/240V 25 kVA
600V
120/240V 25 kVA
SW
-2
SW
-3
SW
-4
SW
-5
'TF-5' 'TF-4'
'TF-3' 'TF-2'
TF-1
CT
CABINET
METER BASE,
METER PROVIDED
BY UTILITY
Scale: NTS
EXISTING DEMOLISH ONE-LINE DIAGRAM
SYMBOL
EXISTING CONDUCTOR/COMPONENT
NEW CONDUCTOR/COMPONENT
FUSED DISCONNECT SWITCH
TRANSFORMER
BREAKER
30/20 AMP COMBINATION PEDESTAL
50/30/20 AMP COMBINATION PEDESTAL
DEMOLISHED EQUIPMENT
ONE LINE DEVICES
SWITCH
JUNCTION BOX
CURRENT TRANSFORMER
TRANSFORMER
ABBREVIATIONS
SW
JB
CT
TF
SITE 21
SITE 22
SITE 23
SITE 24
SITE 25
SITE 26
SITE 27
SITE 28
SITE 29
0A
30A
30A
30A 30A
30A
30A
30A
30A
30A
30A30A
30A
30A
30A
30A
30A
30A30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
OPTION 1TIOT
-4
P
EL
S
'T kVA
A
E 1
SIT
30A
E 2
IT
0A
S
0A
TE
TE
0A
S
0A
TE
0A
SI
0A
E
SIT 9
O ONN
A W
0V
PA
0V
'W
TE
F-4 A
SI
TE
A
SI
E 2
A
SIT
A
E 2
E 2
TE
30A
A
S
TE
A
S 28
TE
OPTION 2 OPTION 3
OPTION 4
BASE IMPROVMENTS
19543
Date: 2021.06.24 17:09:14 -04'00'