ATTACHMENT 5, WESTERN TRANSFORMER SPECIFICATIONS COMPLIANCE DOCUMENTS
The transformer herein specified, unless otherwise directly stated in these specifications, shall be designed, manufactured, and tested in accordance with the applicable ANSI, IEEE, ASTM, and NEMA standards. Compliance documents include the following:
| Compliance Document - Date |
| Description |
| IEEE 315-1975 |
| Graphic Symbols for Electrical and Electronics Diagrams |
| IEEE 315A-1986 |
| Supplement to Graphic Symbols for Electrical and Electronics Diagrams |
| IEEE 693-2005 |
| Recommended Practice for Seismic Design of Substations |
| IEEE C2 Handbook-2017 |
| National Electrical Safety Code |
| IEEE C37.2-2008 |
| Electrical Power System Device Function Numbers, Acronyms and Content Designations |
| IEEE C57.12.00-2010 |
| Liquid-Immersed Distribution, Power, and Regulating Transformers |
| IEEE C57.12.10-2010 |
| Requirements for Liquid Immersed Power Transformers |
| IEEE C57.12.80-2010 |
| Terminology for Power and Distribution Transformers |
| IEEE C57.12.90-2010 |
| Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers and Guide for Short-Circuit Testing of Distribution and Power Transformers |
| IEEE C57.13-2008 |
| Instrument Transformers |
| IEEE C57.13.1-2006 |
| Field Testing of Relaying Current Transformers |
| IEEE C57.19.00-2004 |
| General Requirements and Test Procedure for Outdoor Power Apparatus Bushings |
| IEEE C57.91-2011 |
| Guide for Loading Mineral Oil Immersed Transformers and Step-Voltage Regulators |
| IEEE C57.93-2007 |
| Guide for Installation of Liquid-Immersed Power Transformers |
| IEEE C57.130-1998 |
| Trial Use Guide for the Use of Dissolved Gas Analysis During Factory Thermal Tests for the Evaluation of Oil Immersed Transformers and Reactors |
| IEEE C57.109-1993 |
| Guide for Liquid Immersed Transformer Through-Fault Current Duration |
| IEEE C57.131-2012 |
| Standard Requirements for Tap Changers |
| IEEE C62.11-2012 |
| Metal-Oxide Surge Arresters for Alternating Current Power Circuits |
| ANSI C119.4-2016 |
| Electrical Connectors |
National Bureau of Standards Technical Note 1204-1985
Calibration of Test Systems for Measuring Power Losses in Transformers
| NEMA CC 1-2009 |
| Electric Power Connections for Substations |
| NEMA SG-4-2009 |
| Alternating Current High Voltage Circuit Breakers |
| NEMA 250-2014 |
| Enclosures for Electrical Equipment |
| ASTM D877-2013 |
| Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids using Disk Electrodes |
| ASTM D1500-2012 |
| Standard Test Method for ASTM Color of Petroleum Products |
| ASTM D1816-2012 |
| Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using VDE Electrodes |
| ASTM D3487-2016 |
| Standard Specifications for Mineral Insulating Oil Used in Electrical Apparatus |