Exhibit B

WOOD UTILITY POLE INSPECTION AND TREATMENT SERVICES,

TRANSMISSION AND DISTRIBUTION LINES

WITHIN THE SIERRA NEVADA REGION

Table 1

POLE CIRCUMFERENCE SAFETY FACTORS (SF)

Original Circumference (inches)

SF4

Reduced Circumference

SF 3.5

SF 3.0

SF 2.65

SF 2.5

SF 2.0

28.7

27.3

26.1

25.6

23.8

29.7

28.2

27.0

26.5

24.6

30.6

29.1

27.9

27.4

25.4

31.6

30.0

28.8

28.2

26.2

32.5

30.9

29.6

29.1

27.0

33.5

31.8

30.5

29.9

27.8

34.4

32.7

31.4

30.8

28.6

35.4

33.6

32.3

31.6

29.4

36.3

34.5

33.1

30.2

37.3

35.4

34.0

33.3

31.0

38.3

36.3

34.9

34.2

31.8

39.2

37.3

35.7

35.1

40.2

38.2

36.6

35.9

33.3

41.1

39.1

37.5

36.8

34.1

42.1

40.0

38.4

37.6

34.9

43.0

40.9

39.2

38.5

35.7

44.0

41.8

40.1

39.3

36.5

45.0

42.7

41.0

40.2

37.3

45.9

43.6

41.8

41.0

38.1

46.9

44.5

42.7

41.9

38.9

47.8

45.4

43.6

42.7

39.7

48.8

46.3

44.5

43.6

40.5

49.7

47.2

45.3

44.5

41.3

50.7

48.2

46.2

45.3

42.1

51.6

49.1

47.1

46.2

42.9

52.6

50.0

47.9

47.0

43.7

53.6

50.9

48.8

47.9

44.4

54.5

51.8

49.7

48.7

45.2

55.5

52.7

50.6

49.6

46.0

56.4

53.6

51.4

50.4

46.8

57.4

54.5

52.3

51.3

47.6

ALLOWABLE REDUCED CIRCUMFERENCE SAFETY FACTORS

No single pole to have SF less than 2.65.

No H-structure to have SF less than 2.65 and no pole to have SF less than 2.

For H-structures, add the SF for each pole together and divide by 2 to obtain the structure SF.

For tension-type structures (dead ends), no pole to have SF less than 2.65.

Table 2

Reduction in Measured Circumferences to Compensate for External Pockets

Measured Circumferences of Pole (inches)

Width of Pocket (inches)

Depth of Pocket (inches)

30 to 40

40 to 50

50 to 60

Table 3

Reduction in Measured Circumferences to Compensate for Hollow Heart

Measured Circumferences of Pole

Minimum Thickness of Shell (inches)

3 1/2

4 1/2

30 to 40

Table 4

Reduction in Measured Circumferences to Compensate for Enclosed Pockets

Measured Circumferences of Poles (inches)

Diameter of Pocket (inches)

Measured Thickness of Shell (inches)

30 to 40

Table 5

Reduction in Measured Circumferences to Compensate for External Pockets

Measured Circumferences of Pole (inches)

Width of Pocket (inches)

Depth of Pocket (inches)

30 to 40

File details come from the government source that posted it. Updated .