GILA-GILA VALLEY 34.5KV

TRANSMISSION LINE REBUILD

ARIZONA

SECTION C

DESCRIPTION/SPECIFICATIONS

Spec. No. 787

Looking East toward Gila Substation

GILA-GILA VALLEY 34.5-KV TRANSMISSION LINE REBUILD

PROJECT DRAWINGS

A. GENERAL:

CONSTRUCTION STANDARD DRAWINGS: A complete set of standard drawings are available at http://www.wapa.gov/business/buys.htm. Construction drawings are the specification drawings and any additional drawings required for use in construction. The construction drawings will be issued after contract award and may include amendment changes and other details, which make the drawings suitable to use for construction purposes.

PROJECT DRAWINGS: Project drawings included herein are reduced reproductions and are not to scale. Some project drawings show details of fabrication and other information not a part of the work. Disregard information and details, which are not applicable.

STANDARD DRAWINGS: Where details shown on standard drawings included herein differ from project drawings or text, the details of project drawings or text shall govern.

INFORMATIONAL DRAWINGS: Some project drawings have the words “FOR INFORMATION ONLY” appearing above the title block. These drawings show some information, which may be required for bidding purposes.

These drawings do not show items to be furnished or work to be performed.

EXISTING INSTALLATION DRAWINGS: Some project drawings have the words “EXISTING INSTALLATION” appearing above the title block. These drawings show the existing installations prior to modifications and may show some new work to be performed.

REFERENCE DRAWINGS: Reference drawings referred to on project drawings and not included herein, are not necessary for bidding purposes.

CONTRACTOR'S RESPONSIBILITY: Check all drawings and advise Western of any errors or omissions.

B. LIST OF DRAWINGS:

LOCATION MAP:

1. GLA 0015 Rev. B FIO – Gila Substation Location Map (For Information Only)

TRANSMISSION LINE STEEL POLE STRUCTURES:

2. 43-017D 2200 – 017D Pole Structures Outline and Design Loads

3. 43-017N 2200 – 017N Pole Structures Outline and Design Loads

4. 43-017X 2200 – 017X Pole Structures Outline and Design Loads

5. 43-017X 2201 – 017X Modified Steel Pole Structures Outline and Design Loads

6. 43-024W 2200 – Rev. B – 024W Pole Structures Outline and Design Loads

CHM INDUSTRIES, INC. TRANSMISSION LINE STEEL POLE STRUCTURES – SHOP DRAWINGS:

7. 43-017X 2300 – 017X Pole Structure Pole Outline Details

8. 43-017X 2401 – 017X Pole Structure Pole Provision Details

TRANSMISSION LINE SIGNS AND MARKER BALLS:

9. 41 9027 Rev. E – Steel Pole Structures Aerial Patrol Mile Marker and Structure Number Signs Details and

Locations

10. 41 9028 Rev. D – Steel Pole Structures Aerial Patrol Warning Signs Details and Locations

11. 41 9029 Rev. B – Aerial Patrol Warning Signs and Marker Ball Marking Diagrams

TRANSMISSION LINE ELECTRICAL:

12. GLA-GIV 1000 – Material Quantities Map

13. GLA-GIV 1001 – Material Quantities

14. GLA-GIV 1002 – Vibration Dampers

15. 31 1075 Rev. I – Switch Operating and Equipment Platforms – Electrical Design and Details

16. 31 2014 Rev. B – Switch Operating Platforms – Steel Design and Details

PLAN AND PROFILES:

17. GLA-GIV 4010 – Plan and Profile Summary Key Map

18. GLA-GIV 4011 – Plan and Profile Gila Sub to APS Str. 12/17

19. GLA-GIV 4015 – Plan and Profile APS Str. 10/11 to Str. 3/9

20. GLA-GIV 4016 – Plan and Profile Str. 3/9 to Str. 4/10

21. GLA-GIV 4017 – Plan and Profile Str. 4/10 to Str. 5/5

22. GLA-YUT 4054 EI – Plan and Profile Sta. 153+20 to Sta. 211+44 (Existing Installation)

23. GLA-YUT 4055 EI – Plan and Profile Sta. 207+90 to Sta. 262+14 (Existing Installation)

GEOLOGY:

24. GLA-YUT 8000 – Gila-Yuma Tap Distribution Line Location of Boring – Sheet 1

25. GLA-YUT 8003 – Gila-Yuma Tap Distribution Line Log of Boring No. PR09-02

26. GLA-YUT 8004 – Gila-Yuma Tap Distribution Line Log of Boring No. PR09-03

27. GLA-YUT 8005 – Gila-Yuma Tap Distribution Line Log of Boring No. PR09-04 http://www.wapa.gov/business/buys.htm

0/5

0/4

0/3

0/2

4/7

4/7-1N (NOTE 4)

4/7-2N

4/7-3N

4/7-4N

4/7-5N

4/7-6N

4/7-7N

4/7-8N

4/7-1S

4/7-2S

4/7-3S

4/7-4S

5/5-1

5/5-2

5/5-3

5/5-4

5/5-5

5/5-6

5/5-7

5/5-8

5/5-9 (NOTE 4)

0/9-2

0/9-3

0/9-4

0/9-5

0/9-6

0/9-7

0/9-8

0/9-9

0/9-10

0/9-11

0/9-12 (NOTE 5)

0/9-13

0/9-14 0/9-15

2/10-1

2/10-2

2/10-3

2/10-4

2/10-5

2/10-6

2/10-7

2/10-8

2/10-9

3/6-1

3/6-2

3/6-3

3/6-4

3/6-5

ALIGNMENT C

ALIGNMENT D

ALIGNMENT E

ALIGNMENT F

ALIGNMENT G

ALIGNMENT H

ALIGNMENT A

APS 13/2

(EXIST)

D

E

F

H

C

A

G

APS 10/3 (EXIST.)

A R

A B

Y

R

O A

D

A V

E N

U E

C O

L L

E G

E

A

V E

N U

E

A V

E N

O T

O N

D O

R I V

E

A V

E N

24TH STREET

4/7-9N (NOTE 4)

4/7-10N (NOTE 4)

3/6-6

V I E

W

P

A R

K W

A Y

A V

E N

S

A v e n u e

E

24TH STREET

V I S

T A

L

I

N

T

E

R

S

T

A

0/1

(EXIST.)

C A

S T

I L

L

I V

E

GILA-YUMA TAP 4/4

APS 7/14 (EXIST.)

APS 8/7 (EXIST.)

A V

E N

3/63/7 3/83/93/10

3/113/12 3/134/14/2

4/34/4 4/54/64/84/9

4/104/114/125/15/25/35/4

ALIGNMENT B

B

APS 10/15

(EXIST.)

APS 11/1

APS 12/1

GILA TOS

(EXIST.)

APS 13/1

APS 12/16

(EXIST.)

5/5

0/9-1

(NOTE 7)

(NOTE 5)

(NOTE 4)

(NOTE 5)

(NOTE 6)

(NOTE 4)

(NOTE 4)

0/5

0/4

0/3

0/2

ALIGNMENT A

APS 13/2

(EXIST)

A V

E N

0/1

(EXIST.)

GILA TOS

(EXIST.)

(NOTE 7)

2/10-1

2/10-2

2/10-3

2/10-4

2/10-5

2/10-6

2/10-7

2/10-8

2/10-9

ALIGNMENT D

APS 10/15

(EXIST.)

(NOTE 4)

3/6-1

3/6-2

3/6-3

3/6-4

3/6-5

ALIGNMENT E

APS 10/3 (EXIST.)

A V

E N

3/6-6

3/6 3/7

(NOTE 5)

4/7

4/7-1N (NOTE 4)

4/7-2N

4/7-3N

4/7-4N

4/7-5N

4/7-6N

4/7-7N

4/7-8N

ALIGNMENT F

4/7-9N (NOTE 4)

4/7-10N (NOTE 4)

APS 8/7 (EXIST.)

A V

E N

4/64/8

(NOTE 4)

5/5-1

5/5-2

5/5-3

5/5-4

5/5-5

5/5-6

5/5-7

5/5-8

5/5-9 (NOTE 4)

ALIGNMENT H

H

APS 7/14 (EXIST.)

5/45/5

0/9-2

0/9-3

0/9-4

0/9-5

0/9-6

0/9-7

0/9-8

0/9-9

0/9-10

0/9-11

0/9-12 (NOTE 5)

0/9-13

0/9-14 0/9-15

ALIGNMENT C

C

O T

O N

I V

E

C A

S T

I L

I V

E

APS 12/16

(EXIST.)

0/9-1

(NOTE 5)

4/7

4/7-1S

4/7-2S

4/7-3S

4/7-4S

ALIGNMENT G

GILA-YUMA TAP 4/4

APS 8/7 (EXIST.)

4/6 4/8

(NOTE 6)

4/7

4/7-1N (NOTE 4)

4/7-1S

5/5-1

3/6-1

APS 10/3 (EXIST.)

24TH STREET

APS 7/14 (EXIST.)

APS 8/7 (EXIST.)

3/6 3/73/8

3/93/103/11 3/123/134/14/24/3

4/44/54/6 4/84/94/104/114/12

5/15/25/35/4

ALIGNMENT B

B

5/5

(NOTE 4)

(NOTE 4)

CORPORATE SERVICES OFFICE - LAKEWOOD, COLORADO

JUNE 6, 2013

plathrop Typewritten Text plathrop Typewritten Text plathrop Typewritten Text plathrop Typewritten Text plathrop Text Box plathrop Typewritten Text plathrop Typewritten Text

JUNE 6, 2013

plathrop Typewritten Text plathrop Typewritten Text plathrop Typewritten Text plathrop Typewritten Text

0+00 10+00 20+00 30+00 40+00

P I

°0

'0

P I

°4

'0

G

IV

T

S

A

.0

X

.3

Y

.1

P I

-0 °0

'5

P I

R D

E D

G

E

D

G E

O F

W A

T

IL

A G

R A

V

IT

C

N

G E

O F

W A

T

/1

A

.5

.4

P R

O A

C H

T O

W E

R T

-3

IS

T

IN

G L

A T

T

IC

/2

A

.8

.7

D

-5

NO OGW

P I

-0 °0

'3

/3

A

D

I

°0

'1

/4

A

.2

D

I

°0

'5

/5

A

.6

W

I

°3

'2

M

IS

C M

O N

H

B

S

A

A

IS

T

IN

G S

T E

E L

P O

I

-9

°0

'3

S E

W E

R L

IN

S

A

I

°1

'0

D C

A

E

D

G

S T

S A

S

A

.9

S

A

S

A

S

A

335 375

S49°42'22"W

SEC 1,T9S R22W

SEC 36,T8S R22W

S T

LT

-1

.1

F L

IG

H

T P

I P

O B

C P

,5

/8 R

E B

A R

N83°35'35"W

W

SEC 1,T9S R22W

SEC 36,T8S R22W

F L

IG

H

T P

I P

O B

C /L

E A

R T

H D

IT

C

H

6.

5 0

0.

G

IL

A G

R A

V

IT

Y C

A N

A L

C P

,5

/8 R

E B

A R

2.

G

IL

A G

R A

V

IT

Y C

A N

A L

GLA-YU

10+00

N83°36'25"W

UT 34.5-KV

N83°38'02"W

SET 5/8 INCH

W/1.5"AC. ST

CP 51, RLS24

N83°37'45"W

20+00

SEC 1,T9S R22W

APN 1411209002009

YUMA, ARIZONA

D /G

W A

P A

P O

L E

/5

M

IS

C M

O N

H

U B

H REBAR

TAMPED

T C

TV

G

/G

C A

B L

E M

A R

K E

R

F F

-1

W

P A

P O

L E

M

IS

C

M O

N

H

.0

U G

W A

T E

R X

C A

B L

E M

A R

K E

R

+0

N

°3 7'

"W

S

G

SG

T

W

U G

C A

B L

E M

A R

K E

R

F

-1

C A

B L

E M

A R

K E

R

F

-1

H

O N

P A

/A P

S P

O L

E

W

A T

.0

U G

W A

T E

R X

4T

H S

T

30+00 40+00

SEC 35,T8S R22W

SEC 2,T9S R22W

G T

S S

C

TV

T C

TV

G

G G

T T

S

S

W

W

W

.0

A V

E

.0

T

E R

X

C A

B L

E M

A R

K

F

-1

C A

B L

E M

A R

K

F

-1

.0

O

F F

-3

.9

"B

C

IN

H H

R L

S

C M

O N

S

T A

V E

P

A /A

P S

P O

L E

O

W A

T

G

S

T

.8

O F

F

24TH ST.

0+00.00 0°00'00"

0+61.36 46°42'03" 9+78.89

-0°00'51" 14+35.74 -0°01'36"

18+60.25 0°00'17"

22+86.61 0°01'56"

26+15.79 83°31'26"

41+37.97 0°16'05"

0/1

0/1

0/2 0/3 0/3 0/4 0/5 0/5 APS 13/2 APS 12/20 APS 12/19 APS 12/18 APS 12/17

C A

E

ELECTRICAL ENGINEERING MANAGER D

E

S

IG

N R

E F.

F

IL

LS

CENTERLINE

1"=200' HORIZONTAL

1"=40' VERTICAL

SCALE:

APPROVED DESIGNED

NOTES:

1. GILA-GILA VALLEY 34.5-KV TRANSMISSION LINE IS DOUBLE CIRCUIT WITH APS 69-KV

TRANSMISSION LINE FOR APPROXIMATELY THREE MILES FROM APS STR. 13/2 TO

APS STR. 10/3.

RULING

SPAN

STRUCTURE NUMBER "HAWK"

CONDUCTOR

NESC TMAX

OGW

NESC

457.7 0/2 0/3 4800 1940

424.2 0/3 0/4 4800 1940

425.9 0/4 0/5 4800 1940

326 0/5 APS 13/2 4800 1800

FROM TO TMAX

A B C

LOOKING AHEAD

TOS

LOOKING AHEAD

APS 13/2

LOOKING AHEAD

STR NO. 0/1

LOOKING AHEAD

017D, 024W

A

OGW

A B C

PHASING

PHASING

OGW

PHASING

OGW

PHASING

4011 GLA-GIV

SUPERSEDES DWG NO. GLA-GIV 4000-1A (IN PART)

ALIGNMENT "A"

R. M. CLARK DENE M. CLAIR

ALIGNMENT "A"

FUTURE ALIGNMENT

ALIGNMENT "FUTURE"

A B C C

JUNE 6, 2013

B

NESC LIGHT LOADING

COND. - 2/0, 7-STRAND, HD COPPER (TOS TO STR. 0/1)

COND. - 4/0, AAC, 7-STRAND, "OXLIP" (STR. 0/1 TO STR. 0/2)

COND. - 477 KCM, ACSR, 26/7, "HAWK" (STR. 0/2 TO APS 13/2)

CURVE SHOWN AT 176°F, FINAL CONDITIONS

OGW - 3/8-INCH, HS, 7-STRAND STEEL

CURVE SHOWN AT 0°F, INITIAL CONDITIONS

DESIGN RULING SPAN VARIES

GROUND CLEARANCE = 22 FT. MINIMUM

MAXIMUM DESIGN OPERATING TEMP. = 176°F

STRUCTURE SPOTTING BY PLS-CADD

WESTERN AREA POWER ADMINISTRATION

UNITED STATES DEPARTMENT OF ENERGY

C A

E

CORPORATE SERVICES OFFICE - LAKEWOOD, COLORADO

D E

S

IG

N R

E F.

F

IL

1"=40' VERTICAL

SCALE:

GILA SUB TOS TO APS STR. 12/17

TOS

0+61.36

PI 46°42`03" 0+00

STA -5+00 TO STA 41+38

N88°58`59"W

S89°46`03"W

N83°35`49"W A V

E . 9

APN 1411275900007

APN 1410833003000

S E

C

, T

S R

C

, T

S

R

C

C

SEC 35, T8S R22W

PLAN & PROFILE

G L

A

G

IV

.X

Z

P

R O

J E

C T

S \T

R A

N S

M

IS

S

IO

N L

IN

E S

\G

IL

A G

IL

A

V A

L L E

Y .2

\P

L S

C A

D D

\X Y

Z

G L A

G

IV

COORDINATES AND BEARINGS ARE BASED

ON THE ARIZONA STATE PLAN COORDINATE

SYSTEM, WEST ZONE, NAD83 DATUM.

UNITS ARE IN US SURVEY FEET.

34.5-KV TRANSMISSION LINE

GILA-GILA VALLEY

CONSTRUCTED FOR 69-KV OPERATION.

160+00 170+00 180+00 190+00 200+00

P I

-1 °2

'0

P P

U G

C O

M M

F

IB

E C

P E

D

M E

T

E C

P E

D

M E

T

F F

IC

IG

I

°2

'4

P P

E L

E C

P E

D

E L

E C

T B

A

F F

IC

L

IG

H

T A

R M

S O

U

S

A

I

-0 °1

'4

A

W E

R

.H

S

A

I

°4

'0

P P

A

W E

R

E C

T V

A U

L

P O

L E

O F

F

-8

-T

R A

N S

T

X

W E

R

S

/9

A

I

-2 °1

'2

A

IR

E H

Y D

R A

N T

S

/8

A

I

°1

'0

A

T E

R

T E

R

W E

R

W E

R

W E

R

L P

O L

E O

F F

-1

S

/7

A

S

/6

A

S

A

P I

-8

°3

'0

A

S

A

O T

E

290 145

P I

°0

'5

W

A P

A X

S

A

A

IG

N M

E N

T

B

G G G

G U

Y P

O L

E A

T T

A C

H M

E

U B

P O

F

.5

U

G P

E T

F

.9

U

G P

E T

F

.1

U

G P

E T

A

N

A

X

-4

A

X

A

X

522 399 400 400

160+00

S P

P

P P

F

IB

.6

O F

F

-7

E

C C

O R

A R

A B

Y /2

.C

H .H

M O

V E

/1

K

V B

U

K

L E

/9

P

T A

F F

IC

S

IG

T R

A F

F

IC

A

S T

O F

F W

E S

T

A F

F

IC

L

IG

H T

A R

M W

E

S T P P

P H

O N

E T

R A

F F

IC

L

IG

H

T A

R M

S O

U T

H A

P S

A P

S

S

S E

W E

R M

.H

S E

W E

R M

.H

A P

S

A P

S

170+00

G

S ST P

P

S E

W E

R

E C

T R

A N

S F

O R

M E

R

L E

C T

V A

U

E C

T R

A N

S F

O R

M E

R

-T R

A N

S

T X

R A

N S

T

X

W E

R

F

-2

.6

K

V P

O L

E

70+00

W A

P A

P O

L E

/2 K

IN

D

R

G A

N

IP

.8

O F

F

-1

.1

F

-3

.0

K

V P

O L

E

180+00

V

IE

W P

K W

Y

G G

S W

A T

E R

M H

,W A

T E

R M

.H W

A P

A P

O L

E F

L S

E W

E R

M .H

S E

W E

R M

.H

D /G

R E

M O

V E

,6

/1

K V

P O

L E

0/

E

N D

W A

P A

P O

L E

/4

A P

S

A P

S

A P

S

SEC 4, T9S R22W

770+00

G

W A

P A

P O

L E

/5 K

IN

D

R

G A

N

P A

X

IN

G

.0

W A

P A

X -I

N G

P

A P

O L

E

/6

A

M O

V E

/1

K

V P

O L

E

C

3 1 8 0+ 0 0

1 90+ 00 G

33 4

G

A

M O

/1

/4

E D

P O

C

M O

N

H

P A

X

IN

G

.0

W A

P A

X -I

M O

V E

/1

K V

P O

L E

/3

190+00 200+00

G G G

P A

X

IN

G

A P

A X

-I

P A

P O

L E

M

O V

E

/1

K V

P O

L E

C M

O N

H

Y

P O

L E

A T

T A

C H

M E

U

B P

O

.4

O F

F

.1

"B

O

N C

. R L

S

P A

P O

L E

/7 K

IN

D

E R

M O

R G

M

O V

E

/1

K V

P O

L E

S N

E W

S T

R

S T

A K

E D

P O

.3

O F

F

.5

U

G P

E T

P

A P

O L

E

M O

V E

/1

K

V P

O L

E

S

N E

W S

T R

S

T A

K E

D P

O

.2

O F

F

.9

U

G P

E T

P

A P

O

M O

V E

/1

K

V P

O L

E

S

N E

W S

T R

S

T A

K E

D P

O

.7

O F

F

.1

U

G P

E T

P

A P

O

S N

E W

S T

R

S T

A K

E D

P O

M

O V

E

/1

K V

P O

L E

S

T W

E

C

S E

C

163+81.02 0°24'48"

166+30.50 -0°12'46"

170+33.53 0°46'09"

174+23.53 -2°11'28"

181+83.90 2°13'06"

186+18.65 -88°31'06"

APS 10/11

APS 10/10

APS 10/10

APS 10/9

APS 10/9 APS 10/8 APS 10/8

APS 10/7

APS 10/7 APS 10/6 APS 10/5 APS 10/5

APS 10/4 APS 10/3

3/6 3/6 3/7 3/8 3/9

WESTERN AREA POWER ADMINISTRATION

UNITED STATES DEPARTMENT OF ENERGY

C A

E

CORPORATE SERVICES OFFICE - LAKEWOOD, COLORADO

D E

S

IG

N R

E F.

F

IL

SCALE:

C A

E

ELECTRICAL ENGINEERING MANAGER D

E

S

IG

N R

E F.

F

IL

1"=40' VERTICAL

SCALE:

APPROVED DESIGNED

LOOKING AHEAD

APS

OGW

PHASING

4015 GLA-GIV

SUPERSEDES DWG NO. GLA-GIV 4001C (IN PART)

R. M. CLARK DENE M. CLAIR

ALIGNMENT "FUTURE"

OGW

RULING

SPAN

STRUCTURE NUMBER "HAWK"

CONDUCTOR

NESC TMAX

OGW

NESC

FROM TO TMAX

65 APS 10/3 3/6 3000 1050

ALIGNMENT "B"

B A

OGW

LOOKING AHEAD

APS 10/3

A B C

PHASING

OGW

LOOKING AHEAD

017X

C

PHASING

OGW

LOOKING AHEAD

017N

A B C

PHASING

ALIGNMENT "E"

FUTURE ALIGNMENT

414.2 3/6 4/6 4200 1760

1. GILA-GILA VALLEY 34.5-KV TRANSMISSION LINE IS DOUBLE CIRCUIT WITH

APS 69-KV TRANSMISSION LINE FOR APPROXIMATELY THREE MILES FROM

APS STR. 13/2 TO APS STR. 10/3.

NOTES: ALIGNMENT "B"

NESC LIGHT LOADING

COND.-477 KCM, ACSR, 26/7, "HAWK" (APS 10/3 TO STR. 5/5)

CURVE SHOWN AT 176°F, FINAL CONDITIONS

OGW - 3/8-INCH, HS, 7-STRAND STEEL

CURVE SHOWN AT 0°F, INITIAL CONDITIONS

DESIGN RULING SPAN VARIES

GROUND CLEARANCE = 22 FT. MINIMUM

MAXIMUM DESIGN OPERATING TEMP. = 176°F

STRUCTURE SPOTTING BY PLS-CADD

JUNE 6, 2013

APS STR. 10/11 TO STR. 3/9

STA 159+35 TO STA 203+51

S89°10`42"W

S89°35`29"W S89°22`43"W N89°51`08"W S87°57`24"W

N89°49`30"W S01°48`56"W S89°45`20"W

APN 1411212043006

APN 1410831011025

A P

N

N

N

N

N

N

SEC 33,T8S R22W

YUMA COUNTY, ARIZONA

A R

A B

Y

SEC 4,T9S R22W

A P

N

SEC 32,T8S R22W

SEC 4,T9S R22W SEC 5,T9S R22W

A P

N

APN 1411213001025

P

N

PLAN & PROFILE

G L

A

G

IV

.X

P

R O

J E

C T

S \T

R A

N S

M

IS

S

IO

N L

IN

E S

\G

IL

A G

IL

A

V A

L L E

Y .2

\P

L S

C A

D D

\X Y

Z

G L A

G

IV

SYSTEM, WEST ZONE, NAD83 DATUM.

UNITS ARE IN US SURVEY FEET.

34.5-KV TRANSMISSION LINE

GILA-GILA VALLEY

CONSTRUCTED FOR 69-KV OPERATION.

ALIGNMENT

"E" TAP

210+00 220+00 230+00 240+00 250+00

P I

°1

'0

G

P

G G G G G

O F

F

.6

U

G P

E T

F

.7

U

G P

E T

F

.6

U

G P

E T

E D

E D

E

D

G

P A

X

A

X

A

X

A

X

A

X

A

X -4

M

O

T E

A

X

A

X

A

X

A

X

A

X

A

W

A

N

E

C

IA

L O

R

IE

N T

A T

IO

400 450 440 184 171

355 355

434 435

P I

-0 °0

'0

A

X

381 240

A

X

-4

M

O T

E

A

X

A

X

544 400

50+00

210+00 220+00 230+00 G

P

P

G G G G P

W A

P A

P O

L E

A P

S N

E W

S T

R

S T

A K

E D

P O

M

O V

E

/1

K V

P O

L E

S

T W

E

S N

E W

S T

R

S T

A K

E D

P O

M O

V E

/1

L E

/8

X

F

.1

/1

L E

/8

X

.3

O F

F

.6

U

G P

E T

P

A P

O L

E

S N

E W

S T

R

S T

A K

E D

P O

M

O V

E

/1

K V

P O

L E

P A

P O

L E

.3

O F

F

.7

U

G P

E T

S N

E W

S T

R

S T

A K

E D

P O

M O

V E

/1

K

V P

O L

E

.1

O F

F

.6

U

G P

E T

S N

E W

S T

R

S T

A K

E D

P O

P

A P

O L

E

.9

O F

F

.8

O N

C . R

L S

/4 C

F

.5

/1

L E

/5

T A

P S

M O

V E

/1

L E

/5

T A

P S

C M

O N

"1

B

R M

K R

P

IP

E

A P

S N

E W

S T

R

S T

A K

E D

P O

G A

S

.9

O

F F

P A

X

IN

G

A P

A X

-T R

A N

S P

O L

E /P

E T

E

E C

T R

A N

S F

O R

M E

R

S

N E

W S

T R

S

T A

K E

D P

O

P A

P O

F

.4

K V

P O

L E

P A

P O

F

.0

K

V P

O L

E

P A

P O

A

D W

A

B R

T E

S T

W E

F

.8

K V

P O

L E

A

D W

A

P A

P O

F

.6

K

V P

O L

E

P A

P O

F

.5

K

V P

O L

E

P A

P O

P

A P

O

M P

C

E C

T R

A N

S F

O R

M

E L

E C

S A

V E

E

F E

N C

E /G

A T

E F

E N

C E

/G A

T E

W A

P A

P O

L E

/8

E O

F

IE

LD

E

O F

IE

LD

U S

B R

T E

S T

W E

L L

O F

F

-3

.3

9/

K

V P

O

LE

8/

E O

F

IE

LD

E

O F

IE

LD

O F

F

.4

,6

/1

K

V P

O L

E

/7

O F

F

.8

,6

/1

K

V P

O L

E

/6 W

A P

A

T R

A N

S P

O L

E

O F

F

.6

,6

/1

K

V P

O L

E

/5 E

O F

IE

LD

W A

P A

T

R A

N S

P O

L E

S A

V E

E

S89°58`31"W

250+00 P

W A

P A

T

R A

N S

P O

L E

E L

E C

T R

A N

S F

O R

M E

R

4 7

1.

W A

P A

P O

L E

O F

F

.9

,6

/1

K

V P

O L

E

/4

O F

F

.3

,6

/1

K

V P

O L

E

/3

W A

P A

P O

L E

E O

F

IE

LD

O

F F

.6

,6

/1

K V

P O

L E

/2

U S

B R

T E

S T

W E

L L

O F

F

.6

,6

/1

K

V P

O L

E

/1

SEC 6, T9S, R22W

S89°54`26"W

240+89.24 0°16'09"

247+10.68 -0°07'03"

3/9 3/10 3/11 3/12 3/13 4/1 4/2 4/3 4/4 4/5 4/6 4/7 4/7 4/8 4/9 4/9 4/10

WESTERN AREA POWER ADMINISTRATION

UNITED STATES DEPARTMENT OF ENERGY

C A

E

CORPORATE SERVICES OFFICE - LAKEWOOD, COLORADO

D E

S

IG

N R

E F.

F

IL

SCALE:

C A

E

ELECTRICAL ENGINEERING MANAGER D

E

S

IG

N R

E F.

F

IL

1"=40' VERTICAL

SCALE:

APPROVED DESIGNED

RULING

SPAN

STRUCTURE NUMBER "HAWK"

CONDUCTOR

NESC TMAX FROM TO

414.2 3/6 4/6 4200 1760

434.6 4/6 4/7 4200 1760

421.6 4/7 5/5 4400 1825

OGW

NESC

TMAX

4016 GLA-GIV

SUPERSEDES DWG NO. GLA-GIV 4001C (IN PART)

R. M. CLARK DENE M. CLAIR

ALIGNMENT "B"

AND GLA-GIV 4002A (IN PART)

ALIGNMENT "B"

PHASING

A C B

LOOKING SOUTH

ALIGNMENT "G" TAP

PHASING

C

017X

LOOKING AHEAD

OGW

A B

PHASING

C B A

017N, 024W

LOOKING AHEAD

OGW

ALIGNMENT "F"

ALIGNMENT "G"

72.2 4/7 APS 8/7 3500 1200 JUNE 6, 2013

PHASING

LOOKING NORTH

ALIGNMENT "F" TAP

STR. NO. 4/7-1S

NOTES:

1. STR. NO. 3/13 AND STR. NO. 4/9 EACH CONTAIN THREE

SURGE ARRESTERS, THREE FUSED CUTOUTS, THREE

34.5-KV/440-V TRANSFORMERS, AND ONE CONDUIT.

THE 440-V CONDUCTORS FROM THE SECONDARY SIDE OF

THE TRANSFORMERS FEED USBR PUMPS. WESTERN

2. GILA-GILA VALLEY 34.5-KV TRANSMISSION LINE IS DOUBLE

CIRCUIT WITH APS 69-KV TRANSMISSION LINE FOR

APPROXIMATELY THREE MILES FROM APS STR.13/2 TO

APS STR. 10/3.

MAINTAINS ALL EQUIPMENT ON THE PRIMARY SIDE OF THE

TRANSFORMERS AND USBR MAINTAINS ALL EQUIPMENT

ON THE SECONDARY SIDE OF TRANSFORMERS.

A C B

APS 8/7

69-KV

APS

NESC LIGHT LOADING

COND.-477 KCM, ACSR, 26/7, "HAWK"

CURVE SHOWN AT 176°F, FINAL CONDITIONS

OGW - 3/8-INCH, HS, 7-STRAND STEEL

CURVE SHOWN AT 0°F, INITIAL CONDITIONS

DESIGN RULING SPAN VARIES

GROUND CLEARANCE = 22 FT. MINIMUM

MAXIMUM DESIGN OPERATING TEMP. = 176°F

STRUCTURE SPOTTING BY PLS-CADD

STR. 3/9 TO STR. 4/10

ALIGNMENT

"G" TAP

STA 200+04 TO STA 256+20

S89°45`20"W N89°58`31"W S89°54`26"W

SEC 32,T8S R22W

SEC 5,T9S R22W

APN 1411213001025

APN 1411213001025

A P

N

APN 1411213001025

P

N

APN 1411214029048 SEC 5 T9S R22W

SEC31 T8S R22W

SEC32 T8S R22W

ALIGNMENT

"F" TAP

4/7-1S

APS 8/7

ARIZONA

PLAN & PROFILE

G L

A

G

IV

.X

P

R O

J E

C T

S \T

R A

N S

M

IS

S

IO

N L

IN

E S

\G

IL

A G

IL

A

V A

L L E

Y .2

\P

L S

C A

D D

\X Y

Z

G L A

G

IV

SYSTEM, WEST ZONE, NAD83 DATUM.

UNITS ARE IN US SURVEY FEET.

34.5-KV TRANSMISSION LINE

GILA-GILA VALLEY

CONSTRUCTED FOR 69-KV OPERATION.

260+00 270+00 280+00 290+00 300+00

P I

°1

'1

A

X

A

X

I

-0 °3

'4

A

X

I

°1

'4

A

X

I

°1

'5

A

X

A

X

A

X

A

N

IG

N M

E N

T

B

253 400

W A

P A

P O

L E

E O

F

IE

LD

O

F F

.6

,6

/1

K V

P O

L E

/2

U S

B R

T E

S T

W E

L L

O F

F

.6

,6

/1

K

V P

O L

E

/1

W A

P A

P O

L E

260+00

W A

P A

P O

C A

N

C A

N

F

.8

/1

K

V P

O

P A

P O

60+00

A

P A

P O

F

.7

/1

K

V P

O L

E

F

.5

/1

K

V P

O L

E

P A

P O

280+00270+00

A

P A

P O

F

.4

/1

K

V P

O L

E

B A

R

P R

O P

C

IR

O

N

/ X

.8

O F

F

.8

"B

IN

H

H D

A T

E D

P A

P O

/1

K V

S T

E E

L P

O

.2

O F

F

/1

E

E L

P O

L E

-1

F T

P A

L M

T R

F

T P

A L

M T

R

/1

K V

S T

E E

L P

O

.6

O F

F

/1

E

E L

P O

L E

-1

P A

P O

F

T P

A L

M T

R

F T

P A

L M

T R

F

.2

/1

K V

P O

L E

L T

F

.0

/1

K

V P

O L

E

P

A P

O

F

.5

/1

K

V P

O L

E

P A

P O

1010+00

280+00

O F

F

.0

/1

C

K P

O L

E

.1

O

F F

-3

.2

A

D O

T

P A

P O

.2

O

F F

-2

D

O T

256+54.93 0°16'10"

260+56.13 -0°30'44"

265+53.22 0°17'44"

4/10 4/11 4/11 4/12 4/12 5/1

WESTERN AREA POWER ADMINISTRATION

UNITED STATES DEPARTMENT OF ENERGY

C A

E

CORPORATE SERVICES OFFICE - LAKEWOOD, COLORADO

D E

S

IG

N R

E F.

F

IL

SCALE:

C A

E

ELECTRICAL ENGINEERING MANAGER D

E

S

IG

N R

E F.

F

IL

1"=40' VERTICAL

SCALE:

APPROVED DESIGNED

RULING

SPAN

STRUCTURE NUMBER "HAWK"

CONDUCTOR

NESC TMAX FROM TO

421.6 4/7 5/5 4400 1825

OGW

NESC

TMAX

4017 GLA-GIV

SUPERSEDES DWG NO. GLA-GIV 4002A (IN PART)

R. M. CLARK DENE M. CLAIR

ALIGNMENT "B"

ALIGNMENT "B"

PHASING

C B A

017N

LOOKING AHEAD

OGW

PHASING

C

017X

LOOKING AHEAD

OGW

A B

ALIGNMENT "H" 1. GILA-GILA VALLEY 34.5-KV TRANSMISSION LINE IS DOUBLE

CIRCUIT WITH APS 69-KV TRANSMISSION LINE FOR

APPROXIMATELY THREE MILES FROM APS STR.13/2 TO

APS STR. 10/3.

NOTES:

JUNE 6, 2013

NESC LIGHT LOADING

COND.-477 KCM, ACSR, 26/7, "HAWK"

CURVE SHOWN AT 176°F, FINAL CONDITIONS

OGW - 3/8-INCH, HS, 7-STRAND STEEL

CURVE SHOWN AT 0°F, INITIAL CONDITIONS

DESIGN RULING SPAN VARIES

GROUND CLEARANCE = 22 FT. MINIMUM

MAXIMUM DESIGN OPERATING TEMP. = 176°F

STRUCTURE SPOTTING BY PLS-CADD

PHASING

LOOKING NORTH

ALIGNMENT "H" TAP

A C B

APS 7/14

69-KV

APS

STR. 4/10 TO STR. 5/5

ALIGNMENT

"H" TAP

STA 252+55 TO STA 304+71

S89°54`26"W N89°49`25"W S89°39`51"W S89°57`35"W

SEC 31,T8S R22W

APN 1410829001003

APN 1411214073009 APN 1411214029039

SEC32 T8S R22W

SEC 6 T9S R22W

YUMA COUNTY, ARIZONA

ARIZONA

PLAN & PROFILE

G L

A

G

IV

.X

P

R O

J E

C T

S \T

R A

N S

M

IS

S

IO

N L

IN

E S

\G

IL

A G

IL

A

V A

L L E

Y .2

\P

L S

C A

D D

\X Y

Z

G L A

G

IV

SYSTEM, WEST ZONE, NAD83 DATUM.

UNITS ARE IN US SURVEY FEET.

34.5-KV TRANSMISSION LINE

GILA-GILA VALLEY

CONSTRUCTED FOR 69-KV OPERATION.

APS

7/14

160+00 170+00 180+00 190+00 200+00 210+00

G

A R

A B

Y

G A

S

G A

S L

IN

E

X

C P

O

ID

E W

A L

K E

D

E W

A L

K E

D

E W

A L

K E

D

E W

A L

K E

D

E W

A L

K E

D

M H

M

A N

H O

N A

L E

D

N A

L E

D

A

IN

L

IN

K F

E N

A

IN

L

IN

K

F E

N

A

IN

L

IN

K F

E N

T

A C

H P

O

W

IT

H T

A P

W

E L

L S

L L

T A

P O

F F

-2

X

A

X

A

X

A

X

A

X

A

X

A

X

A

X

A

X

A

X

A

X

A

X

-6

A

A

U R

L

D

A

X

A

400 400 400 400 400 360 380

500 400

370 190 700

210+00 200+00 190+00 180+00 170+00 160+00 S89°56'59"W

S E

T9S, R22W, SEC 4

YUMA COUNTY

P

G

H 2O

V A

L V

E

8+

,A

R A

B Y

R D

U G

G A

S

0+

G

A S

L I N

E X

IN

G

0°

T O

C /L

T -L

IN

E

X

IN

G

E L

E C

T R

A N

S F

O R

M E

R

H 2O

M E

T E

R

C P

C

P

S

E T

P K

N A

IL

IN

A S

P A

L T

S S

M H

M

A N

H O

L E

S S

M H

M

A N

H O

L E

S

ID

E W

A

LK

E D

G E

S S

M H

M

A N

H O

L E

S

ID

E W

A

LK

E D

G E

S

ID

E W

A

LK

E D

G E

S S

M H

M

A N

H O

L E

C A

N A

L E

D G

E

9+

C A

N A

L E

D G

E

9+

C H

A

IN

LI

N

K F

E N

C E

A T

T A

C H

P O

L E

A

T W

E L

L S

IT

E

T A

P F

O R

W E

L L

C P

C

P

S

E T

/8

IN

C

H R

E B

A R

F

IR

E H

Y D

R A

N T

M

IS

C P

O L

E

O F

F

5.

,E

L E

C T

L

IN

E

C R

O S

S

IN

G -3

W

IR

E S

-O T

H E

R S

C P

C

P

S

E T

P K

N A

IL

IN

A S

P H

A

LT

S

ID

E W

A

LK

E D

G E

S

ID

E

W A

LK

E

D G

E

C H

A

IN

LI

N

K F

E N

C E

C H

A

IN

LI

N

K F

E N

C E

2/12 2/13 3/1 3/2 3/3 3/4 3/5 3/6 3/7 3/8 3/9 3/10 3/10T 3/11 3/12

PHASING

A B C

LOOKING AHEAD

STR NO. 3/11

C B A

LOOKING AHEAD

PHASING

STR. NO. 3/10T

RULING

SPAN

STRUCTURE

NUMBER

CONDUCTOR

NESC TMAX

OGW

FROM TO

OPGW

NESC

TMAX

NESC

TMAX

392.6 0/2 3/11 4800 3300

190.2 3/10T 3/11 1000

GILA-GILA VALLEY

A B C

GILA-

GILA

VALLEY

SUPERSEDES DWG NO. GLA-YUT 4001-1A

AND 4001-2A (IN PART).

773.5 3/11 4/4 5400 3650

PHASING

LOOKING AHEAD

STR NO. 3/12

C

B

A

C

B

A

GILA-GILA

VALLEY

GILA-YUMA

TAP

SEE

DETAIL

"A"

DETAIL "A"

GILA GILA VALLEY CIRCUIT ONLY

JUMPER &

SLACK SPAN

PUMP DROP 1

NTS

PISTOL

GRIP

POLYMER

INSULATOR

STR. NO. 3/11

POST

INSULATOR

PORCELAIN

DEADEND

NEW 477 KCMIL

MARCH 22, 2012

WESTERN AREA POWER ADMINISTRATION

UNITED STATES DEPARTMENT OF ENERGY

C A

E

CORPORATE SERVICES OFFICE - LAKEWOOD, COLORADO

ELECTRICAL ENGINEERING MANAGER

D E

S

IG

N R

E F.

F

IL

1"=40' VERTICAL

SCALE:

APPROVED DESIGNED

GILA-YUMA TAP

34.5-KV TRANSMISSION LINE

ARIZONA

PLAN & PROFILE

GLA-YUT

ROSS CLARK DENE CLAIR

A R

A B

Y R

D

P U

M P

D R

O

DOUBLE CIRCUIT

GILA-GILA VALLEY

34.5-KV SPUR

(INSULATED

FOR 69-KV)

SEE DRAWING

GLA-GIV 4022

STA 153+20 TO STA 211+44

G L

A

Y U

T

.X

NESC LIGHT LOADING

COND. - 477 KCM, 24/7, "FLICKER"

CURVE SHOWN AT 176°F, FINAL CONDITIONS

OGW - 1/2-INCH, HS, 7-STRAND STEEL

CURVE SHOWN AT 0°F, INITIAL CONDITIONS

DESIGN RULING SPAN VARIES

GROUND CLEARANCE = 22 FT. MINIMUM

MAXIMUM DESIGN OPERATING TEMP. = 176°F

STRUCTURE SPOTTING BY PLS-CADD

COORDINATES AND BEARINGS ARE BASED

ON THE ARIZONA STATE PLAN COORDINATE

SYSTEM, WEST ZONE, NAD83 DATUM.

UNITS ARE IN US SURVEY FEET.

CONSTRUCTED FOR 69-KV OPERATION.

S :\P

R O

JE

C

T S

\T R

A N

S M

IS

S

IO

N

L

IN

E S

\G

IL

A

Y U

M A

T A

P .R

E C

O N

S T

R U

C T

IO

N

.2

\P L

S C

A D

D \X

Y Z

\G L

A

Y U

T

AS BUILT

NOTE:

SEE DRAWING GLA-YUT 1000 FOR MATERIAL QUANTITIES.

lampman

EXISTING INSTALLATION

210+00 220+00 230+00 240+00 250+00 260+00

P I

°2

'4

G

U G

G A

S

G A

S L

IN

E

X

C P

O

R H

O T

T A

P B

IR

D

D

IV

E R

T E

R

N A

L E

D

N A

L E

D

D D

IV

E

R T

E R

. A

V E

X

A

X

A

X

A

X

A

Z

A

X

A

X

A

X

A

870 780

735 395 310

ORANGE

MARKER

BALLS RIGHT

TURN

ARROW B

IV

E R

T E

I -6

°2

'4

S T

-O

-W F

E N

C

A

X

A

N

A

360 417

-O

-W F

E N

250+00 240+00 230+00 220+00 210+00 S89°56'59"W

E

T9S, R22W, SEC 5

YUMA COUNTY

G

U G

G A

S

2+

G

A S

L I N

E X

IN

G

0°

T O

C /L

M

IS

C P

O L

E

O F

F

-2

.4

C P

C

P

M

IS

C P

O L

E

O F

F

-2

.8

M

IS

C P

O L

E

O F

F

-3

.6

M

IS

C P

O L

E

O F

F

.7

M

IS

C P

O L

E

O F

F

.8

A T

T A

C H

P O

L E

F

O R

H O

T T

A P

C A

N A

L E

D G

E

7+

C A

N A

L E

D G

E

7+

,S

A

V E

E

E D

G E

C O

N C

D

IT

C

H

S T

LT

4/4T

260+00 N66°33'12"W

M

IS

C P

O L

E

O F

F

-3

.6

IP

O F

F

-1

.3

R -O

-W F

E N

C E

R -O

-W F

E N

C E

R O

W

S T

LT

260+00

R -O

-W F

E N

C E

R -O

-W F

E N

C E

R -O

-W F

E N

C E

253+38.07 23°29'49"

253+38.07 23°29'49"

261+13.88 -66°27'41"

3/12 4/1 4/2 4/3 4/4 4/5 4/6 4/7 4/8 4/8 4/9 4/10

LOOKING AHEAD

STR NO. 3/12

C

B

A

C

B

A

PHASING

RULING

SPAN

STRUCTURE

NUMBER CONDUCTOR

NESC TMAX

OPGW

NESC

TMAX

OGW

NESC

TMAX FROM TO

773.5 3/11 4/4 5400 3650

369.6 4/4 4/10 4750 3300

GILA-GILA

VALLEY

PHASING

A B C

LOOKING AHEAD

STR NO. 4/4

A B C

GILA-

GILA

VALLEY

PHASING

B C

A

STR NO. 4/5

LOOKING AHEAD

GILA-YUMA

TAP

SUPERSEDES DWG NO. GLA-YUT 4001-2A

AND 4002-1A (IN PART).

PHASING PHASING

A B C

LOOKING AHEAD

STR NO. 4/8

B C

A

STR NO. 4/9

LOOKING AHEAD

PHASING

A B C

LOOKING AHEAD

STR NO. 4/10

SEE

DETAIL

"B"

DETAIL "B"

GILA GILA VALLEY CIRCUIT ONLY

JUMPER

PARALLEL

NTS

GRIP

PORCELAIN

INSULATOR

STR. NO. 4/4

POLYMER

INSULATOR

NEW

GROVE

477 KCMIL

CONNECTOR

PISTOL

EXIST.

COND.

MARCH 22, 2012

PUMP DROP NO. 2

2 4 3 5

A PHASE

B PHASE

C PHASE

1. PG CLAMP 3/0 TO 477 ALCF-483.2P

2. 3/0 SUSPENSION CAMP HAS-85-N

3. CHAIN LINK LK-30

4. 3/4" X 4" BENT BOLT YBC-30

5. 69-KV INSULATOR Y-EYE OB-S025023-S200

6. SUSPENSION CLAMP 477 HAS-104-N

STR 4/3 WELL TAP

DETAIL "C"

NTS

WESTERN AREA POWER ADMINISTRATION

UNITED STATES DEPARTMENT OF ENERGY

C A

E

CORPORATE SERVICES OFFICE - LAKEWOOD, COLORADO

ELECTRICAL ENGINEERING MANAGER

D E

S

IG

N R

E F.

F

IL

1"=40' VERTICAL

SCALE:

APPROVED DESIGNED

GILA-YUMA TAP

34.5-KV TRANSMISSION LINE

ARIZONA

PLAN & PROFILE

GLA-YUT

ROSS CLARK DENE CLAIR

DOUBLE CIRCUIT

GILA-GILA VALLEY 34.5-KV SPUR

(INSULATED FOR 69-KV)

SEE DRAWING

GLA-GIV 4022

P U

M P

D R

O

E D

E T

A

IL

C

A

O

B E

R E

M O

V E

D

INTERSTATE 8

ORANGE

MARKER

BALLS

RIGHT

TURN

ARROW

STA 207+90 TO STA 262+14

G L

A

Y U

T

.X

NESC LIGHT LOADING

COND. - 477 KCM, 24/7, "FLICKER"

CURVE SHOWN AT 176°F, FINAL CONDITIONS

OGW - 1/2-INCH, HS, 7-STRAND STEEL

CURVE SHOWN AT 0°F, INITIAL CONDITIONS

DESIGN RULING SPAN VARIES

GROUND CLEARANCE = 22 FT. MINIMUM

MAXIMUM DESIGN OPERATING TEMP. = 176°F

STRUCTURE SPOTTING BY PLS-CADD

COORDINATES AND BEARINGS ARE BASED

ON THE ARIZONA STATE PLAN COORDINATE

SYSTEM, WEST ZONE, NAD83 DATUM.

UNITS ARE IN US SURVEY FEET.

CONSTRUCTED FOR 69-KV OPERATION.

S :\P

R O

JE

C

T S

\T R

A N

S M

IS

S

IO

N

L

IN

E S

\G

IL

A

Y U

M A

T A

P .R

E C

O N

S T

R U

C T

IO

N

.2

\P L

S C

A D

D \X

Y Z

\G L

A

Y U

T

AS BUILT

NOTE:

SEE DRAWING GLA-YUT 1000 FOR MATERIAL QUANTITIES.

lampman

EXISTING INSTALLATION

gla_0015b
43_017_d_2200
43_017_n_2200
43_017_x_2200
43_017_x_2201
43_024_w_2200b
43_017_x_2300
43_017_x_2401
41_9027e
41_9028d
41_9029b
gla_giv_1000
gla_giv_1001
gla_giv_1002
31_1075i
31_2014b
gla_giv_4010
gla_giv_4011
gla_giv_4015
gla_giv_4016
gla_giv_4017
gla_yut_4054_ei
gla_yut_4055_ei
gla_yut_8000
gla_yut_8003
gla_yut_8004
gla_yut_8005

File details come from the government source that posted it. Updated .