This is a Design Services solicitation document from Stanly Community College (SCC) in North Carolina seeking architectural or engineering design services for the Snyder Building Roof Replacement Project. The project involves the complete removal and replacement of the existing roofing system on the Snyder Building, located at 141 College Drive, Albemarle, NC. The building, constructed in 1997, features a 29-year-old original gravel roof covering approximately 14,650 square feet of the 28,000 square foot two-story structure. The proposed replacement roof system will utilize either a Thermoplastic Polyolefin (TPO) or FiberTite roof system. Proposing firms must submit a Letter of Interest (not to exceed ten single-sided pages or five double-sided pages), a current Standard Form 254 (SF-254), and licensing information via e-submissions only. Submissions must be formatted on 8.5" x 11" pages stapled in the upper left-hand corner, without binders or tabs. Email and fax submittals will not be accepted. Inquiries should be directed to Shannon Shepherd, Director of Administrative and Facility Services, at sshepherd2420@stanly.edu.
The selection committee will evaluate proposals based on ten criteria including specialized expertise in roofing projects, past performance on similar projects, adequate staffing and proposed design team composition, current workload with the state, proposed design approach and consultant team, recent experience with project costs and schedules, construction administration capabilities, proximity and familiarity with the Albemarle area, and record of successfully completed projects without major legal or technical issues. Proposing firms must be properly licensed to practice Architecture, Engineering, or Landscape Architecture in North Carolina in accordance with the NC Board of Architecture, NC Board of Examiners for Engineers & Surveyors, and NC Board of Landscape Architects. The solicitation references NCCS #3016 and SCO #31142 for tracking purposes.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Department/Agency Stanly Community College
Project Title Snyder Building Roof Replacement
Design Services Complete roof removal and replacement
Scope of Work
SCC is in search of a designer for the Snyder Building Roof Replacement Project. Snyder was constructed in 1997 with the original gravel roof still in place. The 29-year-old roof covers roughly 14,650 sq. ft. of this 28,000 sq.
ft. two story building. Snyder is located at 141 College Drive, Albemarle, NC. The project will include the full removal of the current roofing system.
Roof to be replaced with a Thermoplastic Polyolefin roof system (TPO) or FiberTite roof system.
Contact Shannon Shepherd, Director Administrative and Facility Services
Email sshepherd2420@stanly.edu
NCCS #3016; SCO #31142
Submit Letter of Interest, SF-254, and Licensing Information:
e-submissions only
NC Licensing Statement
In order to offer architectural, engineering, or landscape architectural services in response to this solicitation, the proposing firm must be properly licensed to practice Architecture, Engineering, or Landscape Architecture in the State of North Carolina. More information on the North Carolina state boards may be found at the following websites:
NC Board of Architecture: (http://www.ncbarch.org) NC Board of Examiners for Engineers & Surveyors: (http://www.ncbels.org) NC Board of Landscape Architects: (http://www.ncbola.org)
STATE BUILDING COMMISSION - SELECTING CRITERIA
In selecting designers, the selection committee should take into consideration qualification information including such factors as:
1. Specialized or appropriate expertise in the type of project.
2. Past performance on similar projects.
3. Adequate staff and proposed design or consultant team for the project.
4. Current workload and State projects awarded.
5. Proposed design approach for the project including design team and consultants.
6. Recent experience with project costs and schedules.
7. Construction administration capabilities.
8. Proximity to and familiarity with the area where the project is located.
9. Record of successfully completed projects without major legal or technical problems.
10. Other factors which may be appropriate for the project.
STATE BUILDING COMMISSION - SUBMITTAL CRITERIA
Proposing firms must submit a Letter of Interest and a copy of your current Standard Form 254 (SF 254) with the information package. The current SF 254 template is located at http://ncadmin.nc.gov/businesses/construction/forms-documents which is the State Building Commission approved form.
In the interest of cost-savings to the designers, consistency of the submittals and more efficient use of time by the pre-selection committee, the submitted information package should not include any notebooks, binders, tab, clips, etc. The format should be 8-1/2" x 11" pages stapled in the upper left-hand corner. The Letter of Interest should not exceed ten (10) single-sided pages or five (5) double-sided pages plus the SF 254.
E-mail and Fax submittals will not be accepted.
http://www.ncbarch.org/ http://www.ncbels.org/ http://www.ncbola.org/ http://ncadmin.nc.gov/businesses/construction/forms-documents
File details come from the government source that posted it. Updated .