Solicitation IDIQ Breaker_050311_1505.pdf
PDF 430 KB Posted
- Solicitation number
- DE-RQ65-11WA92232
About this file
Solicitation Documents
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 0005 SF30.doc | DOC document | |
| Amendment 004.pdf | ||
| Amendment 0002 SF30.doc | DOC document | |
| Solicitation IDIQ Breaker_050311_1505.docx | DOCX document | |
| Amendment 0001 SF30.pdf | ||
| Attachment_3_31_6013b.pdf | ||
| Attachment_2_31_6012b.pdf | ||
| Attachment_1_31_6011b.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
25. Accounting and Appropriation Data 26. Total Award Amount (For Govt. Use Only)
AS NOTED IN EACH DELIVERY ORDER
X 27a. Solicitation incorporates by reference FAR 52.212-1. FAR 52.212-3, 52.212- and 52.212-5 are attached. Addenda X are are not attached 27b. Contract/Purchase Order incorporates by reference FAR 52.212-4, 52.212-5 is attached. Addenda are are not attached
X 28. Contractor is required to sign this document and return 2 copies to 29. Award of Contract: Reference. Offer
Issuing Office. Contractor agrees to furnish and deliver all items set forth or otherwise identified above and on any additional sheets subject to the terms and conditions specified herein.
Dated . Your offer on Solicitation (Block 5), including any additions or changes which are set forth herein, is accepted as to items:
30a. Signature of Offeror/Contractor 31a. United States of America (Signature of Contracting Officer)
30b. Name and Title of Signer (Type or Print) 30c. Date Signed 31b. Name of Contracting Officer (Type or Print) 31c. Date Signed
32a. Quantity in Column 21 Has Been
Received Inspected Accepted, and Conforms to the Contract, Except as Noted: ________________________
32b. Signature of Authorized Government Representative 32c. Date 32d. Printed Name and Title of Authorized Government Representative
32e. Mailing Address of Authorized Government Representative 32f. Telephone Number of Authorized Government Representative
32g. E-mail of Authorized Government Representative
33. Ship Number 34. Voucher Number 35. Amount Verified Correct
For
36. Payment 37. Check Number
Complete Partial Final
Partial Final
38. S/R Account Number 39. S/R Voucher Number 40. Paid By
41a. I certify this account is correct and proper for payment 42a. Received By (Print)
41b. Signature and Title of Certifying Officer 41c. Date 42b. Received At (Location)
42c. Date Rec'd (YY/MM/DD) 42d. Total Containers
STANDARD FORM 1449 (REV. 4/2002)
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
Offeror to Complete Blocks 12, 17, 23, 24, & 30
1. Requisition Number
92232
2. Contract No. 3. Award/Effective Date 4. Order Number 5. Solicitation Number 6. Solicitation Issue Date DE-RQ65-11WA92232 May 3, 2011
7. For Solicitation
Information Call:
a. Name Venus Y. De Liso (deliso@wapa.gov) b. Telephone Number (No collect calls) 8. Offer Due Date/Local Time
720-962-7234 June 8, 2011 / 4:00 PM MDT
9. Issued By Code 10. This Acquisition is 11. Delivery for FOB Destination Unless Block is Marked. 12. Discount Terms
US DEPARTMENT OF ENERGY
WESTERN AREA POWER
ADMINISTRATION
12155 W. ALAMEDA PARKWAY
ATTN: A7100
LAKEWOOD, CO 80228-2802
Unrestricted
X Set-Aside 100% for See Schedule
X Small Business 13a. This contract is a rated order under DPAS (15 CFR 700)
HubZone Small Business
8(A) 13b. Rating
NAICS: 335313 14. Method of Solicitation
Size Standard: 750 Employees X RFQ IFB RFP
15. Deliver To Code 16. Administered By Code
US DEPARTMENT OF ENERGY
WESTERN AREA POWER ADMINISTRATION
12155 W. ALAMEDA PARKWAY
ATTN: A7100
LAKEWOOD, CO 80228-2802
SEE BLOCK 9
17a. Contractor/Offeror Code Facility Code 18a. Payment Will Be Made By Code
WESTERN AREA POWER ADMINISTRATION
P.O BOX 281111 ATTN: A8210
LAKEWOOD, CO 80228-8111
Telephone No. TIN:
17b. Check if Remittance is Different and Put Such Address in Offer. 18b. Submit Invoices to Address Shown in Block 18a Unless Box Below is Checked.
See Addendum.
19.
ITEM NO.
20.
SCHEDULE OF SUPPLIES/SERVICES
21.
QUANTITY
22.
UNIT
23.
UNIT PRICE
24.
AMOUNT
SEE ATTACHED SCHEDULE
Schedule of Supplies/Service
BID SCHEDULE OF SUPPLIES/SERVICES – Base Year (Contract Year 1) Contract Line Item Number (CLIN) Description
Est.
Qty Unit Unit Price Amount
NOTE: The quantities shown are estimated quantities that shall be used for Government price comparison and evaluation purposes. See also the notes at the end of the Bid Schedules.
11001 Power circuit breaker, dead tank, 362-kV, 3000A, 40-kA rated short-circuit current, three 3000:5A CTs per bushing with C800 accuracy & 1.5 continuous (thermal) RF at 50 degrees C, operation at minus 30 degrees C to plus 40 degrees C, and up to 3,300 feet elevation (@@ See Note 4) 12 EA
11002 Upgrade CLIN 11001 to 4000A, additional cost per breaker, to be ordered with CLIN 11001 for 4000A rating
1 EA
11003 Upgrade either CLIN 11001 or a
11001/11002 combination to 50-kA, additional cost per breaker, to be ordered with 11001 (or 11002) for 50-kA rating [capacitance needed for 50-kA SLF faults not included, see CLINs 11060-11063] 1 EA
11004 Upgrade of either CLIN 11001 or a 11001/11002 combination to 63-kA, additional cost per breaker, to be ordered with 11001 (or 11001/11002) for 63-kA rating [capacitance needed for 63-kA SLF faults not included, see CLINs 11060-11063] 4 EA
11010 Tools and appliances set 4 EA 11011 Spare Parts-Trip & Close Coils set
(3 spare trip coils & 3 spare close coils per set, per technical specifications) 6 EA
11012 Spare parts-Spring Charging Motor
6 EA
11020 Erecting engineer services, straight-time rate [Offeror to enter under:
“Quantity”: the number of hours for 1 breaker x CLIN 11001 quantity;
“Unit Price”: the quoted cost per hour;
”Amount: the extended total] (See Technical Specifications para.1.g)
HR
11021 Erecting engineer services, extra-time rate [Offeror to enter under:
“Quantity”: the number of hours for 1 breaker x CLIN 11001 quantity;
“Unit Price”: the quoted cost per hour;
”Amount: the extended total]
11022 Erecting Engineer Travel, Round Trips
“Quantity” the number of round trips for 1 breaker x CLIN 11001 quantity;
“Unit Price”: the quoted cost per trip;
“Amount:” the extended total]
EA
11030 Delivery and off-loading of one 362-kV breaker and associated delivery order items in UGP (See Note 6) 1 EA
11031 Delivery and off-loading of one 362-kV in RMR (See Note 6) 1 EA
Line Item Number (CLIN) Description
Est.
Qty Unit Unit Price Amount
11032 Delivery and off-loading of one 362-kV breaker and associated delivery order items in DSW (See Note 6) 12 EA
11033 Additional 362-kV breaker delivery & routing cost when high altitude CLIN 11043,11044,11045,or 11046 is ordered, per breaker 12 EA
11040 Operation and full interruption capability of CLIN 11001 from minus 50 degrees C to plus 40 degrees C – including when upgraded by CLIN 11002, 11003, or 11004 1 EA
11041 Operation and full interruption capability of 3000A CLIN 11001 from minus 30 degrees C to plus 50 degrees C – including when upgraded by CLIN 11003 or 11004 12 EA
11042 Operation and full interruption capability of 4000A CLIN 11001/11002 combination from minus 30 degrees C to plus 50 degrees C – including when upgraded by CLIN 11003 or
11004 1 EA
11043 High altitude operation and full interruption capability of 3000A CLIN 11001 at installed elevation above 3,300 feet and up to 6,225 feet – including when upgraded by CLIN 11003 or 11004 (@@ See Note 4) 4 EA
11044 Extra-high altitude operation and full interruption capability of 3000A CLIN 11001 at installed elevation above 3,300 feet and up to 7,200 feet – including when upgraded by CLIN 11003 or 11004 (@@ See Note 4) 8 EA
11045 High altitude operation and full interruption capability of 4000A CLIN 11001/11002 combination at an installed elevation above 3,300 feet and up to 6,225 feet – including when upgraded by CLIN 11003 or 11004 (See Note 4) 1 EA
11046 Extra high altitude operation and full interruption capability of 4000A CLIN 11001/11002 combination at an installed elevation above 3,300 feet and up to 7,200 feet – including when upgraded by CLIN 11003 or 11004 (@@ See Note 4) 1 EA
11050 Set of three extra 3000:5A bushing CTs (BCTs) (1 per bushing for one side of breaker) 1 EA
11051 Set of three extra 2000:5A BCTs, 2.5 (thermal) RF at 50 degrees C (1 per bushing for one side of breaker) 1 EA
11052 Substitution of one set of three 2000:5A BCTs, 2.5 (thermal) RF at 50 degrees C for one set of three 3000:5A BCTs 1 EA
11053 Set of three extra metering accuracy bushing CTs (1 per bushing for one side of breaker)
1 EA
Line Item Number (CLIN) Description
Est.
Qty Unit Unit Price Amount
11060 Set of three *** pf capacitors, factory or field installed “line side”%%, for 50-kA SLF fault ratings of CLIN 11001/11003 combination – including when upgraded to 4000A by CLIN 11002 (***capacitor rating to be determined by breaker mfr, see Note 5)(%% if needed, See Note 3) 1 EA
11061 High/Extra High Altitude Version of CLIN 11060 (%% if needed, See Note 3) 1 EA
11062 Set of three *** pf capacitors, factory or field installed, “bus side” %%, for 50-kA SLF fault ratings of CLIN 11001/11003 combination – including when upgraded to 4000A by CLIN 11002 (***capacitor rating to be determined by breaker mfr, see Note 5) )(%% if needed, See Note 3) 1 EA
11063 High/Extra High Altitude Version of CLIN 11062 (%% if needed, See Note 3) 1 EA
11064 Set of three *** pf capacitors, factory or field installed, “line side”, for 63-kA SLF fault ratings of CLIN 11001/11004 combination – including when upgraded to 4000A by CLIN 11002 (***capacitor rating to be determined by breaker mfr, see Note 5) 4 EA
11065 High/Extra High Altitude Version of CLIN
11064 1 EA
11066 Set of three *** pf capacitors, factory or field installed, “bus side” %%, for 63-kA SLF fault ratings of CLIN 11001/11004 combination – including when upgraded to 4000 A by CLIN 11002 (***capacitor rating to be determined by breaker mfr, see Note 5)(%% if needed, See Note 3) 4 EA
11067 High/Extra High Altitude Version of CLIN 11066 (%% if needed, See Note 3) 1 EA
Total of Base Year CLINs 11001 – 11067
BID SCHEDULE OF SUPPLIES/SERVICES – First Option Year (Contract Year 2)
CLIN Description
Est.
Qty Unit Unit Price Amount
NOTE: The quantities shown are estimated quantities that shall be used for Government price comparison and evaluation purposes. See also the notes at the end of the Bid Schedules.
21001 Power circuit breaker, dead tank, 362-kV, 3000A, 40-kA rated short-circuit current, three 3000:5A CTs per bushing with C800 accuracy & 1.5 continuous (thermal) RF at 50 degrees C, operation at minus 30 degrees C to plus 40 degrees C, and up to 3,300 feet elevation (@@ See Note 4) 2 EA
21002 Upgrade CLIN 21001 to 4000A, additional cost per breaker, to be ordered with CLIN 21001 for 4000A rating
1 EA
21003 Upgrade either CLIN 21001 or a
21001/21002 combination to 50-kA, additional cost per breaker, to be ordered with 21001 (or 21002) for 50-kA rating [capacitance needed for 50-kA SLF faults not included, see CLINs 21060-21063] 1 EA
21004 Upgrade of either CLIN 21001 or a 21001/21002 combination to 63-kA, additional cost per breaker, to be ordered with 21001 (or 21001/21002) for 63-kA rating [capacitance needed for 63-kA SLF faults not included, see CLINs 21060-21063] 1 EA
21010 Tools and appliances set 2 EA 21011 Spare Parts-Trip & Close Coils set
(3 spare trip coils & 3 spare close coils per set, per technical specifications) 2 EA
21012 Spare parts-Spring Charging Motor
1 EA
21020 Erecting engineer services, straight-time rate [Offeror to enter under:
“Quantity”: the number of hours for 1 breaker x CLIN 21001 quantity;
“Unit Price”: the quoted cost per hour;
”Amount: the extended total]
21021 Erecting engineer services, extra-time rate
“Quantity”: the number of hours for 1 breaker x CLIN 21001 quantity;
“Unit Price”: the quoted cost per hour;
”Amount: the extended total]
21022 Erecting Engineer Travel, Round Trips
“Quantity” the number of round trips for 1 breaker x CLIN 21001 quantity;
“Unit Price”: the quoted cost per trip;
“Amount:” the extended total]
21030 Delivery and off-loading of one 362-kV in UGP (See Note 6) 1 EA
21031 Delivery and off-loading of one 362-kV
Est.
Qty Unit Unit Price Amount
21032 Delivery and off-loading of one 362-kV breaker and associated delivery order items in DSW (See Note 6) 1 EA
21033 Additional 362-kV breaker delivery & routing cost when high altitude CLIN 21043,21044,21045,or 21046 is ordered, per breaker 1 EA
21040 Operation and full interruption capability of CLIN 21001 from minus 50 degrees C to plus 40 degrees C – including when upgraded by CLIN 21002, 21003, or 21004 2 EA
21041 Operation and full interruption capability of 3000A CLIN 21001 from minus 30 degrees C to plus 50 degrees C – including when upgraded by CLIN 21003 or 21004 1 EA
21042 Operation and full interruption capability of 4000A CLIN 21001/21002 combination from minus 30 degrees C to plus 50 degrees C – including when upgraded by CLIN 21003 or
21004 1 EA
21043 High altitude operation and full interruption capability of 3000A CLIN 21001 at installed elevation above 3,300 feet and up to 6,225 feet – including when upgraded by CLIN 21003 or 21004 (@@ See Note 4) 1 EA
21044 Extra-high altitude operation and full interruption capability of 3000A CLIN 21001 at installed elevation above 3,300 feet and up to 7,200 feet – including when upgraded by CLIN 21003 or 21004 (@@ See Note 4) 1 EA
21045 High altitude operation and full interruption capability of 4000A CLIN 21001/21002 combination at an installed elevation above 3,300 feet and up to 6,225 feet – including when upgraded by CLIN 21003 or 21004 (See Note 4) 1 EA
21046 Extra high altitude operation and full interruption capability of 4000A CLIN 21001/21002 combination at an installed elevation above 3,300 feet and up to 7,200 feet – including when upgraded by CLIN 21003 or 21004 (@@ See Note 4) 1 EA
21050 Set of three extra 3000:5A bushing CTs (BCTs) (1 per bushing for one side of breaker) 1 EA
21051 Set of three extra 2000:5A BCTs, 2.5 (thermal) RF at 50 degrees C (1 per bushing for one side of breaker) 1 EA
21052 Substitution of one set of three 2000:5A BCTs, 2.5 (thermal) RF at 50 degrees C for one set of three 3000:5A BCTs 1 EA
21053 Set of three extra metering accuracy bushing CTs (1 per bushing for one side of breaker) 1 EA
21060 Set of three *** pf capacitors, factory or field installed “line side”%%, for 50-kA SLF fault ratings of CLIN 21001/21003 combination – including when upgraded to 4000A by CLIN 21002 (***capacitor rating to be determined by breaker mfr, see Note 5)(%% if needed, See Note 3) 1 EA
21061 High/Extra High Altitude Version of CLIN 21060 (%% if needed, See Note 3) 1 EA
21062 Set of three *** pf capacitors, factory or field 1 EA
Qty Unit Unit Price Amount installed, “bus side” %%, for 50-kA SLF fault ratings of CLIN 21001/21003 combination – including when upgraded to 4000A by CLIN 21002 (***capacitor rating to be determined by breaker mfr, see Note 5) )(%% if needed, See Note 3)
21063 High/Extra High Altitude Version of CLIN 21062 (%% if needed, See Note 3) 1 EA
21064 Set of three *** pf capacitors, factory or field installed, “line side”, for 63-kA SLF fault ratings of CLIN 21001/21004 combination – including when upgraded to 4000A by CLIN 21002 (***capacitor rating to be determined by breaker mfr, see Note 5) 1 EA
21065 High/Extra High Altitude Version of CLIN
21064 1 EA
21066 Set of three *** pf capacitors, factory or field installed, “bus side” %%, for 63-kA SLF fault ratings of CLIN 21001/21004 combination – including when upgraded to 4000 A by CLIN 21002 (***capacitor rating to be determined by breaker mfr, see Note 5)(%% if needed, See Note 3) 1 EA
21067 High/Extra High Altitude Version of CLIN 21066 (%% if needed, See Note 3) 1 EA
Total of Option Year 1 (Contract Year 2) CLINs 21001 – 21067
BID SCHEDULE OF SUPPLIES/SERVICES –Second Option Year (Contract Year 3)
Est.
Qty Unit Unit Price Amount
NOTE: The quantities shown are estimated quantities that shall be used for Government price comparison and evaluation purposes. See also the notes at the end of the Bid Schedules.
31001 Power circuit breaker, dead tank, 362-kV, 3000A, 40-kA rated short-circuit current, three 3000:5A CTs per bushing with C800 accuracy & 1.5 continuous (thermal) RF at 50 degrees C, operation at minus 30 degrees C to plus 40 degrees C, and up to 3,300 feet elevation (@@ See Note 4) 2 EA
31002 Upgrade CLIN 31001 to 4000A, additional cost per breaker, to be ordered with CLIN 31001 for 4000A rating
1 EA
31003 Upgrade either CLIN 31001 or a
31001/31002 combination to 50-kA, additional cost per breaker, to be ordered with 31001 (or 31002) for 50-kA rating [capacitance needed for 50-kA SLF faults not included, see CLINs 31060-31063] 1 EA
31004 Upgrade of either CLIN 31001 or a 31001/31002 combination to 63-kA, additional cost per breaker, to be ordered with 31001 (or 31001/31002) for 63-kA rating [capacitance needed for 63-kA SLF faults not included, see CLINs 31060-31063] 1 EA
31010 Tools and appliances set 2 EA 31011 Spare Parts-Trip & Close Coils set
(3 spare trip coils & 3 spare close coils per set, per technical specifications) 2 EA
31012 Spare parts-Spring Charging Motor
1 EA
31020 Erecting engineer services, straight-time rate [Offeror to enter under:
“Quantity”: the number of hours for 1 breaker x CLIN 31001 quantity;
“Unit Price”: the quoted cost per hour;
”Amount: the extended total]
31021 Erecting engineer services, extra-time rate
“Quantity”: the number of hours for 1 breaker x CLIN 31001 quantity;
“Unit Price”: the quoted cost per hour;
”Amount: the extended total]
31022 Erecting Engineer Travel, Round Trips
“Quantity” the number of round trips for 1 breaker x CLIN 31001 quantity;
“Unit Price”: the quoted cost per trip;
“Amount:” the extended total]
31030 Delivery and off-loading of one 362-kV in UGP (See Note 6) 1 EA
31031 Delivery and off-loading of one 362-kV
Qty Unit Unit Price Amount
31032 Delivery and off-loading of one 362-kV breaker and associated delivery order items in DSW (See Note 6) 1 EA
31033 Additional 362-kV breaker delivery & routing cost when high altitude CLIN 31043,31044,31045,or 31046 is ordered, per breaker 1 EA
31040 Operation and full interruption capability of CLIN 31001 from minus 50 degrees C to plus 40 degrees C – including when upgraded by CLIN 31002, 31003, or 31004 2 EA
31041 Operation and full interruption capability of 3000A CLIN 31001 from minus 30 degrees C to plus 50 degrees C – including when upgraded by CLIN 31003 or 31004 1 EA
31042 Operation and full interruption capability of 4000A CLIN 31001/31002 combination from minus 30 degrees C to plus 50 degrees C – including when upgraded by CLIN 31003 or
31004 1 EA
31043 High altitude operation and full interruption capability of 3000A CLIN 31001 at installed elevation above 3,300 feet and up to 6,225 feet – including when upgraded by CLIN 31003 or 31004 (@@ See Note 4) 1 EA
31044 Extra-high altitude operation and full interruption capability of 3000A CLIN 31001 at installed elevation above 3,300 feet and up to 7,200 feet – including when upgraded by CLIN 31003 or 31004 (@@ See Note 4) 1 EA
31045 High altitude operation and full interruption capability of 4000A CLIN 31001/31002 combination at an installed elevation above 3,300 feet and up to 6,225 feet – including when upgraded by CLIN 31003 or 31004 (See Note 4) 1 EA
31046 Extra high altitude operation and full interruption capability of 4000A CLIN 31001/31002 combination at an installed elevation above 3,300 feet and up to 7,200 feet – including when upgraded by CLIN 31003 or 31004 (@@ See Note 4) 1 EA
31050 Set of three extra 3000:5A bushing CTs (BCTs) (1 per bushing for one side of breaker) 1 EA
31051 Set of three extra 2000:5A BCTs, 2.5 (thermal) RF at 50 degrees C (1 per bushing for one side of breaker) 1 EA
31052 Substitution of one set of three 2000:5A BCTs, 2.5 (thermal) RF at 50 degrees C for one set of three 3000:5A BCTs 1 EA
31053 Set of three extra metering accuracy bushing CTs (1 per bushing for one side of breaker) 1 EA
31060 Set of three *** pf capacitors, factory or field installed “line side”%%, for 50-kA SLF fault ratings of CLIN 31001/31003 combination – including when upgraded to 4000A by CLIN 31002 (***capacitor rating to be determined by breaker mfr, see Note 5)(%% if needed, See Note 3) 1 EA
31061 High/Extra High Altitude Version of CLIN 31060 (%% if needed, See Note 3) 1 EA
31062 Set of three *** pf capacitors, factory or field 1 EA
Qty Unit Unit Price Amount installed, “bus side” %%, for 50-kA SLF fault ratings of CLIN 31001/31003 combination – including when upgraded to 4000A by CLIN 31002 (***capacitor rating to be determined by breaker mfr, see Note 5) )(%% if needed, See Note 3)
31063 High/Extra High Altitude Version of CLIN 31062 (%% if needed, See Note 3) 1 EA
31064 Set of three *** pf capacitors, factory or field installed, “line side”, for 63-kA SLF fault ratings of CLIN 31001/31004 combination – including when upgraded to 4000A by CLIN 31002 (***capacitor rating to be determined by breaker mfr, see Note 5) 1 EA
31065 High/Extra High Altitude Version of CLIN
31064 1 EA
31066 Set of three *** pf capacitors, factory or field installed, “bus side” %%, for 63-kA SLF fault ratings of CLIN 31001/31004 combination – including when upgraded to 4000 A by CLIN 31002 (***capacitor rating to be determined by breaker mfr, see Note 5)(%% if needed, See Note 3) 1 EA
31067 High/Extra High Altitude Version of CLIN 31066 (%% if needed, See Note 3) 1 EA
Total of Option Year 2 (Contract Year 3) CLINs 31001 – 31067
BID SCHEDULE OF SUPPLIES/SERVICES –Third Option Year (Contract Year 4)
Est.
Qty Unit Unit Price Amount
NOTE: The quantities shown are estimated quantities that shall be used for Government price comparison and evaluation purposes. See also the notes at the end of the Bid Schedules.
41001 Power circuit breaker, dead tank, 362-kV, 3000A, 40-kA rated short-circuit current, three 3000:5A CTs per bushing with C800 accuracy & 1.5 continuous (thermal) RF at 50 degrees C, operation at minus 30 degrees C to plus 40 degrees C, and up to 3,300 feet elevation (@@ See Note 4) 2 EA
41002 Upgrade CLIN 41001 to 4000A, additional cost per breaker, to be ordered with CLIN 41001 for 4000A rating
1 EA
41003 Upgrade either CLIN 41001 or a
41001/41002 combination to 50-kA, additional cost per breaker, to be ordered with 41001 (or 41002) for 50-kA rating [capacitance needed for 50-kA SLF faults not included, see CLINs 41060-41063] 1 EA
41004 Upgrade of either CLIN 41001 or a 41001/41002 combination to 63-kA, additional cost per breaker, to be ordered with 41001 (or 41001/41002) for 63-kA rating [capacitance needed for 63-kA SLF faults not included, see CLINs 41060-41063] 1 EA
41010 Tools and appliances set 2 EA 41011 Spare Parts-Trip & Close Coils set
(3 spare trip coils & 3 spare close coils per set, per technical specifications) 2 EA
41012 Spare parts-Spring Charging Motor
1 EA
41020 Erecting engineer services, straight-time rate [Offeror to enter under:
“Quantity”: the number of hours for 1 breaker x CLIN 41001 quantity;
“Unit Price”: the quoted cost per hour;
”Amount: the extended total]
41021 Erecting engineer services, extra-time rate
“Quantity”: the number of hours for 1 breaker x CLIN 41001 quantity;
“Unit Price”: the quoted cost per hour;
”Amount: the extended total]
41022 Erecting Engineer Travel, Round Trips
“Quantity” the number of round trips for 1 breaker x CLIN 41001 quantity;
“Unit Price”: the quoted cost per trip;
“Amount:” the extended total]
41030 Delivery and off-loading of one 362-kV in UGP (See Note 6) 1 EA
41031 Delivery and off-loading of one 362-kV
Qty Unit Unit Price Amount
41032 Delivery and off-loading of one 362-kV breaker and associated delivery order items in DSW (See Note 6) 1 EA
41033 Additional 362-kV breaker delivery & routing cost when high altitude CLIN 41043,41044,41045,or 41046 is ordered, per breaker 1 EA
41040 Operation and full interruption capability of CLIN 41001 from minus 50 degrees C to plus 40 degrees C – including when upgraded by CLIN 41002, 41003, or 41004 2 EA
41041 Operation and full interruption capability of 3000A CLIN 41001 from minus 30 degrees C to plus 50 degrees C – including when upgraded by CLIN 41003 or 41004 1 EA
41042 Operation and full interruption capability of 4000A CLIN 41001/41002 combination from minus 30 degrees C to plus 50 degrees C – including when upgraded by CLIN 41003 or
41004 1 EA
41043 High altitude operation and full interruption capability of 3000A CLIN 41001 at installed elevation above 3,300 feet and up to 6,225 feet – including when upgraded by CLIN 41003 or 41004 (@@ See Note 4) 1 EA
41044 Extra-high altitude operation and full interruption capability of 3000A CLIN 41001 at installed elevation above 3,300 feet and up to 7,200 feet – including when upgraded by CLIN 41003 or 41004 (@@ See Note 4) 1 EA
41045 High altitude operation and full interruption capability of 4000A CLIN 41001/41002 combination at an installed elevation above 3,300 feet and up to 6,225 feet – including when upgraded by CLIN 41003 or 41004 (See Note 4) 1 EA
41046 Extra high altitude operation and full interruption capability of 4000A CLIN 41001/41002 combination at an installed elevation above 3,300 feet and up to 7,200 feet – including when upgraded by CLIN 41003 or 41004 (@@ See Note 4) 1 EA
41050 Set of three extra 3000:5A bushing CTs (BCTs) (1 per bushing for one side of breaker) 1 EA
41051 Set of three extra 2000:5A BCTs, 2.5 (thermal) RF at 50 degrees C (1 per bushing for one side of breaker) 1 EA
41052 Substitution of one set of three 2000:5A BCTs, 2.5 (thermal) RF at 50 degrees C for one set of three 3000:5A BCTs 1 EA
41053 Set of three extra metering accuracy bushing CTs (1 per bushing for one side of breaker) 1 EA
41060 Set of three *** pf capacitors, factory or field installed “line side”%%, for 50-kA SLF fault ratings of CLIN 41001/41003 combination – including when upgraded to 4000A by CLIN 41002 (***capacitor rating to be determined by breaker mfr, see Note 5)(%% if needed, See Note 3) 1 EA
41061 High/Extra High Altitude Version of CLIN 41060 (%% if needed, See Note 3) 1 EA
41062 Set of three *** pf capacitors, factory or field 1 EA
Qty Unit Unit Price Amount installed, “bus side” %%, for 50-kA SLF fault ratings of CLIN 41001/41003 combination – including when upgraded to 4000A by CLIN 41002 (***capacitor rating to be determined by breaker mfr, see Note 5) )(%% if needed, See Note 3)
41063 High/Extra High Altitude Version of CLIN 41062 (%% if needed, See Note 3) 1 EA
41064 Set of three *** pf capacitors, factory or field installed, “line side”, for 63-kA SLF fault ratings of CLIN 41001/41004 combination – including when upgraded to 4000A by CLIN 41002 (***capacitor rating to be determined by breaker mfr, see Note 5) 1 EA
41065 High/Extra High Altitude Version of CLIN
41064 1 EA
41066 Set of three *** pf capacitors, factory or field installed, “bus side” %%, for 63-kA SLF fault ratings of CLIN 41001/41004 combination – including when upgraded to 4000 A by CLIN 41002 (***capacitor rating to be determined by breaker mfr, see Note 5)(%% if needed, See Note 3) 1 EA
41067 High/Extra High Altitude Version of CLIN 41066 (%% if needed, See Note 3) 1 EA
Total of Option Year 3 (Contract Year 4) CLINs 41001 – 41067
BID SCHEDULE OF SUPPLIES/SERVICES – Fourth Option Year (Contract Year 5)
Est.
Qty Unit Unit Price Amount
NOTE: The quantities shown are estimated quantities that shall be used for Government price comparison and evaluation purposes. See also the notes at the end of the Bid Schedules.
51001 Power circuit breaker, dead tank, 362-kV, 3000A, 40-kA rated short-circuit current, three 3000:5A CTs per bushing with C800 accuracy & 1.5 continuous (thermal) RF at 50 degrees C, operation at minus 30 degrees C to plus 40 degrees C, and up to 3,300 feet elevation (@@ See Note 4) 2 EA
51002 Upgrade CLIN 51001 to 4000A, additional cost per breaker, to be ordered with CLIN 51001 for 4000A rating
1 EA
51003 Upgrade either CLIN 51001 or a
51001/51002 combination to 50-kA, additional cost per breaker, to be ordered with 51001 (or 51002) for 50-kA rating [capacitance needed for 50-kA SLF faults not included, see CLINs 51060-51063] 1 EA
51004 Upgrade of either CLIN 51001 or a 51001/51002 combination to 63-kA, additional cost per breaker, to be ordered with 51001 (or 51001/51002) for 63-kA rating [capacitance needed for 63-kA SLF faults not included, see CLINs 51060-51063] 1 EA
51010 Tools and appliances set 2 EA 51011 Spare Parts-Trip & Close Coils set
(3 spare trip coils & 3 spare close coils per set, per technical specifications) 2 EA
51012 Spare parts-Spring Charging Motor
1 EA
51020 Erecting engineer services, straight-time rate [Offeror to enter under:
“Quantity”: the number of hours for 1 breaker x CLIN 51001 quantity;
“Unit Price”: the quoted cost per hour;
”Amount: the extended total]
51021 Erecting engineer services, extra-time rate
“Quantity”: the number of hours for 1 breaker x CLIN 51001 quantity;
“Unit Price”: the quoted cost per hour;
”Amount: the extended total]
51022 Erecting Engineer Travel, Round Trips
“Quantity” the number of round trips for 1 breaker x CLIN 51001 quantity;
“Unit Price”: the quoted cost per trip;
“Amount:” the extended total]
51030 Delivery and off-loading of one 362-kV in UGP (See Note 6) 1 EA
51031 Delivery and off-loading of one 362-kV
Qty Unit Unit Price Amount
51032 Delivery and off-loading of one 362-kV breaker and associated delivery order items in DSW (See Note 6) 1 EA
51033 Additional 362-kV breaker delivery & routing cost when high altitude CLIN 51043,51044,51045,or 51046 is ordered, per breaker 1 EA
51040 Operation and full interruption capability of CLIN 51001 from minus 50 degrees C to plus 40 degrees C – including when upgraded by CLIN 51002, 51003, or 51004 2 EA
51041 Operation and full interruption capability of 3000A CLIN 51001 from minus 30 degrees C to plus 50 degrees C – including when upgraded by CLIN 51003 or 51004 1 EA
51042 Operation and full interruption capability of 4000A CLIN 51001/51002 combination from minus 30 degrees C to plus 50 degrees C – including when upgraded by CLIN 51003 or
51004 1 EA
51043 High altitude operation and full interruption capability of 3000A CLIN 51001 at installed elevation above 3,300 feet and up to 6,225 feet – including when upgraded by CLIN 51003 or 51004 (@@ See Note 4) 1 EA
51044 Extra-high altitude operation and full interruption capability of 3000A CLIN 51001 at installed elevation above 3,300 feet and up to 7,200 feet – including when upgraded by CLIN 51003 or 51004 (@@ See Note 4) 1 EA
51045 High altitude operation and full interruption capability of 4000A CLIN 51001/51002 combination at an installed elevation above 3,300 feet and up to 6,225 feet – including when upgraded by CLIN 51003 or 51004 (See Note 4) 1 EA
51046 Extra high altitude operation and full interruption capability of 4000A CLIN 51001/51002 combination at an installed elevation above 3,300 feet and up to 7,200 feet – including when upgraded by CLIN 51003 or 51004 (@@ See Note 4) 1 EA
51050 Set of three extra 3000:5A bushing CTs (BCTs) (1 per bushing for one side of breaker) 1 EA
51051 Set of three extra 2000:5A BCTs, 2.5 (thermal) RF at 50 degrees C (1 per bushing for one side of breaker) 1 EA
51052 Substitution of one set of three 2000:5A BCTs, 2.5 (thermal) RF at 50 degrees C for one set of three 3000:5A BCTs 1 EA
51053 Set of three extra metering accuracy bushing CTs (1 per bushing for one side of breaker) 1 EA
51060 Set of three *** pf capacitors, factory or field installed “line side”%%, for 50-kA SLF fault ratings of CLIN 51001/51003 combination – including when upgraded to 4000A by CLIN 51002 (***capacitor rating to be determined by breaker mfr, see Note 5)(%% if needed, See Note 3) 1 EA
51061 High/Extra High Altitude Version of CLIN 51060 (%% if needed, See Note 3) 1 EA
51062 Set of three *** pf capacitors, factory or field 1 EA
Qty Unit Unit Price Amount installed, “bus side” %%, for 50-kA SLF fault ratings of CLIN 51001/51003 combination – including when upgraded to 4000A by CLIN 51002 (***capacitor rating to be determined by breaker mfr, see Note 5) )(%% if needed, See Note 3)
51063 High/Extra High Altitude Version of CLIN 51062 (%% if needed, See Note 3) 1 EA
51064 Set of three *** pf capacitors, factory or field installed, “line side”, for 63-kA SLF fault ratings of CLIN 51001/51004 combination – including when upgraded to 4000A by CLIN 51002 (***capacitor rating to be determined by breaker mfr, see Note 5) 1 EA
51065 High/Extra High Altitude Version of CLIN
51064 1 EA
51066 Set of three *** pf capacitors, factory or field installed, “bus side” %%, for 63-kA SLF fault ratings of CLIN 51001/51004 combination – including when upgraded to 4000 A by CLIN 51002 (***capacitor rating to be determined by breaker mfr, see Note 5)(%% if needed, See Note 3) 1 EA
51067 High/Extra High Altitude Version of CLIN 51066 (%% if needed, See Note 3) 1 EA
Total of Option Year 4 (Contract Year 5) CLINs 51001 – 51067
GRAND TOTAL FOR BASE AND
ALL OPTIONS
Bid Schedule Notes:
1. Western Area Power Administration (Western) intends to award one Indefinite Delivery/
Indefinite Quantity contract as a result of this solicitation. All Contract Line Item Numbers (CLINs) shall be awarded to only one supplier providing equipment from a single manufacturer. Offerors are required to submit a quote for all CLINs, including $0.00 cost items per Notes 2 & 3 below.
Requirements for Contract Year 1 CLINs 11001 – 11067 also apply to the corresponding succeeding contract year CLINs 21001-21067, 31001-31067, 41001-41067, and 51001- 51067.
2. Should any of the above CLINS not be applicable for a manufacturer’s product line, i.e., where an upgrade listed under a CLIN is already included in the base/standard breaker CLIN 11001 ratings, the offeror is expected to enter $0.00 for cost and clarify/explain this in the supplemental narrative. An example might be if the breaker quoted for CLIN 11001 is already rated for 50-kA, then upgrade CLIN 11003 would have a $0.00 cost.
(See Addendum to 52.212-1(m)(5)).
3. %% If additional capacitance is not needed for this requirement, the offeror may enter
$0.00 for cost and clarify /explain this in the supplemental narrative. (See Addendum to 52.212-1(m)(5)).
4. @@ If the standard /base breaker offered for the CLINs identified in Note 1 is rated for installation at an elevation higher than 3,300 feet, the Contractor shall clarify and explain this in the supplemental narrative. (See Addendum to 52.212-1(m)(5)).
5. *** Contractor/vendor to provide the amount of added capacitance needed for each of these requirements as part of the supplemental/narrative. (See Addendum to 52.212- 1(m)(5)).
6. Delivery Locations: See attached map showing approximate geographical boundaries of
Western’s Regions. As on that map:
“UGP” refers to Western’s “Upper Great Plains Region” For this contract, the anticipated/projected “UGP” delivery points may be within the central and eastern portions of South Dakota and Nebraska.
“RMR” refers to Western’s “Rocky Mountain Region”
For this contract, the anticipated/projected “RMR” delivery points may be within the northwestern and southwestern portions of Colorado
“DSW” refers to Western’s “Desert Southwest Region” For this contract, the anticipated/projected “DSW” delivery points may be within the northwestern portion of New Mexico, the central and western portions of Arizona, and/or eastern Nevada.
7. Delivery orders shall be issued by mail, fax or e-mail.
8. Total magnitude of this contract shall not exceed Six Million Four Hundred Ninety-Nine
Thousand ($6,499,000) dollars.
CLINs 11001-11067 Delivery Schedules (also for 21001-21067, 31001-31067, 41001-41067, 51001-51067)
The following is the Government’s required delivery schedule.
CLIN QUANTITY DELIVERY
11001 1-4 Within 300 days after date of delivery order.# 11001 From 5 to 10 Within 360 days after date of delivery order.#
11001/11002 combination
1-4 Within 330 days after date of delivery order.#
11001/11002 combination
From 5 to 10 Within 360 days after date of delivery order.#
11001/11003 combination
Any/All Within 360 days after date of delivery order.#
11001/11004 combination
Any/All Within 360 days after date of delivery order.#
11001/11002, 11001/11003, 11001/11004, combinations w/ high altitude bushings
Any/All Add 60 days to delivery window for breakers ordered with high altitude bushings
11010-11011, (Tools and
Spare Parts)
All Delivery time for these CLINs shall be the same as delivery times for the corresponding breaker, or within 60 days after date of delivery order if ordered separately.
11020-11022 (Erecting Engineer Services)
All Within 365 days after delivery of breaker, or as specified in the delivery order. See Technical Specifications subparagraph 1.g(4) for specific notification requirements.
11033 – 11067
All CLINs 11033–11067 are selectable features/functions that will be installed on the circuit breakers for this CLIN as specified in each delivery order. Accordingly, delivery time for these CLINs shall be the same as for the corresponding breaker.
# Delivery schedule dates will be specified on individual delivery orders.
Delivery dates may be specified to be later than the minimum times listed above.
Contract Clauses
1. 52.212-4 CONTRACT TERMS AND CONDITIONS--COMMERCIAL ITEMS (JUN 2010)
(a) Inspection/Acceptance. The Contractor shall only tender for acceptance those items that conform to the requirements of this contract. The Government reserves the right to inspect or test any supplies or services that have been tendered for acceptance. The Government may require repair or replacement of nonconforming supplies or reperformance of nonconforming services at no increase in contract price. If repair/replacement or reperformance will not correct the defects or is not possible, the government may seek an equitable price reduction or adequate consideration for acceptance of nonconforming supplies or services. The Government must exercise its post-acceptance rights
(1) Within a reasonable time after the defect was discovered or should have been discovered; and
(2) Before any substantial change occurs in the condition of the item, unless the change is due to the defect in the item.
(b) Assignment. The Contractor or its assignee may assign its rights to receive payment due as a result of performance of this contract to a bank, trust company, or other financing institution, including any Federal lending agency in accordance with the Assignment of Claims Act (31 U.S.C.3727).
However, when a third party makes payment (e.g., use of the Government-wide commercial purchase card), the Contractor may not assign its rights to receive payment under this contract.
(c) Changes. Changes in the terms and conditions of this contract may be made only by written agreement of the parties.
(d) Disputes. This contract is subject to the Contract Disputes Act of 1978, as amended (41 U.S.C. 601-613). Failure of the parties to this contract to reach agreement on any request for equitable adjustment, claim, appeal or action arising under or relating to this contract shall be a dispute to be resolved in accordance with the clause at FAR 52.233-1, Disputes, which is incorporated herein by reference. The Contractor shall proceed diligently with performance of this contract, pending final resolution of any dispute arising under the contract.
(e) Definitions. The clause at FAR 52.202-1, Definitions, is incorporated herein by reference.
(f) Excusable delays. The Contractor shall be liable for default unless nonperformance is caused by an occurrence beyond the reasonable control of the Contractor and without its fault or negligence such as, acts of God or the public enemy, acts of the Government in either its sovereign or contractual capacity, fires, floods, epidemics, quarantine restrictions, strikes, unusually severe weather, and delays of common carriers. The Contractor shall notify the Contracting Officer in writing as soon as it is reasonably possible after the commencement of any excusable delay, setting forth the full particulars in connection therewith, shall remedy such occurrence with all reasonable dispatch, and shall promptly give written notice to the Contracting Officer of the cessation of such occurrence.
(g) Invoice.
(1) The Contractor shall submit an original invoice and three copies (or electronic invoice, if authorized) to the address designated in the contract to receive invoices. An invoice must include --
(i) Name and address of the Contractor;
(ii) Invoice date and number;
(iii) Contract number, contract line item number and, if applicable, the order number;
(iv) Description, quantity, unit of measure, unit price and extended price of the items delivered;
(v) Shipping number and date of shipment, including the bill of lading number and weight of shipment if shipped on Government bill of lading;
(vi) Terms of any discount for prompt payment offered;
(vii) Name and address of official to whom payment is to be sent;
(viii) Name, title, and phone number of person to notify in event of defective invoice; and
(ix) Taxpayer Identification Number (TIN). The Contractor shall include its TIN on the invoice only if required elsewhere in this contract.
(x) Electronic funds transfer (EFT) banking information.
(A) The Contractor shall include EFT banking information on the invoice only if required elsewhere in this contract.
(B) If EFT banking information is not required to be on the invoice, in order for the invoice to be a proper invoice, the Contractor shall have submitted correct EFT banking information in accordance with the applicable solicitation provision, contract clause (e.g., 52.232-33, Payment by Electronic Funds Transfer—Central Contractor Registration, or 52.232- 34, Payment by Electronic Funds Transfer—Other Than Central Contractor Registration), or applicable agency procedures.
(C) EFT banking information is not required if the Government waived the requirement to pay by EFT.
(2) Invoices will be handled in accordance with the Prompt Payment Act (31 U.S.C. 3903) and Office of Management and Budget (OMB) prompt payment regulations at 5 CFR part 1315.
(h) Patent indemnity. The Contractor shall indemnify the Government and its officers, employees and agents against liability, including costs, for actual or alleged direct or contributory infringement of, or inducement to infringe, any United States or foreign patent, trademark or copyright, arising out of the performance of this contract, provided the Contractor is reasonably notified of such claims and proceedings.
(i) Payment.
(1) Items accepted. Payment shall be made for items accepted by the Government that have been delivered to the delivery destinations set forth in this contract.
(2) Prompt Payment. The Government will make payment in accordance with the Prompt Payment Act (31 U.S.C. 3903) and prompt payment regulations at 5 CFR Part 1315.
(3) Electronic Funds Transfer (EFT). If the Government makes payment by EFT, see 52.212-5(b) for the appropriate EFT clause.
(4) Discount. In connection with any discount offered for early payment, time shall be computed from the date of the invoice. For the purpose of computing the discount earned, payment shall be considered to have been made on the date which appears on the payment check or the specified payment date if an electronic funds transfer payment is made.
(5) Overpayments. If the Contractor becomes aware of a duplicate contract financing or invoice payment or that the Government has otherwise overpaid on a contract financing or invoice payment, the Contractor shall—
(i) Remit the overpayment amount to the payment office cited in the contract along with a description of the overpayment including the—
(A) Circumstances of the overpayment (e.g., duplicate payment, erroneous payment, liquidation errors, date(s) of overpayment);
(B) Affected contract number and delivery order number, if applicable;
(C) Affected contract line item or subline item, if applicable; and
(D) Contractor point of contact.
(ii) Provide a copy of the remittance and supporting documentation to the Contracting Officer.
(6) Interest.
(i) All amounts that become payable by the Contractor to the Government under this contract shall bear simple interest from the date due until paid unless paid within 30 days of becoming due. The interest rate shall be the interest rate established by the Secretary of the Treasury as provided in Section 611 of the Contract Disputes Act of
1978 (Public Law 95-563), which is applicable to the period in which the amount becomes due, as provided in (i)(6)(v) of this clause, and then at the rate applicable for each six-month period at fixed by the Secretary until the amount is paid.
(ii) The Government may issue a demand for payment to the Contractor upon finding a debt is due under the contract.
(iii) Final decisions. The Contracting Officer will issue a final decision as required by 33.211 if—
(A) The Contracting Officer and the Contractor are unable to reach agreement on the existence or amount of a debt within 30 days;
(B) The Contractor fails to liquidate a debt previously demanded by the Contracting Officer within the timeline specified in the demand for payment unless the amounts were not repaid because the Contractor has requested an installment payment agreement; or
(C) The Contractor requests a deferment of collection on a debt previously demanded by the Contracting Officer (see 32.607-2).
(iv) If a demand for payment was previously issued for the debt, the demand for payment included in the final decision shall identify the same due date as the original demand for payment.
(v) Amounts shall be due at the earliest of the following dates:
(A) The date fixed under this contract.
(B) The date of the first written demand for payment, including any demand for payment resulting from a default termination.
(vi) The interest charge shall be computed for the actual number of calendar days involved beginning on the due date and ending on—
(A) The date on which the designated office receives payment from the Contractor;
(B) The date of issuance of a Government check to the Contractor from which an amount otherwise payable has been withheld as a credit against the contract debt;
or
(C) The date on which an amount withheld and applied to the contract debt would otherwise have become payable to the Contractor.
(vii) The interest charge made under this clause may be reduced under the procedures prescribed in 32.608-2 of the Federal Acquisition Regulation in effect on the date of this contract.
(j) Risk of loss. Unless the contract specifically provides otherwise, risk of loss or damage to the supplies provided under this contract shall remain with the Contractor until, and shall pass to the Government upon:
(1) Delivery of the supplies to a carrier, if transportation is f.o.b. origin; or
(2) Delivery of the supplies to the Government at the destination specified in the contract, if transportation is f.o.b.
destination.
(k) Taxes. The contract price includes all applicable Federal, State, and local taxes and duties.
(l) Termination for the Government’s convenience. The Government reserves the right to terminate this contract, or any part hereof, for its sole convenience. In the event of such termination, the Contractor shall immediately stop all work hereunder and shall immediately cause any and all of its suppliers and subcontractors to cease work. Subject to the terms of this contract, the Contractor shall be paid a percentage of the contract price reflecting the percentage of the work performed prior to the notice of termination, plus reasonable charges the Contractor can demonstrate to the satisfaction of the Government using its standard record keeping system, have resulted from the termination. The Contractor shall not be required to comply with the cost accounting standards or contract cost principles for this purpose. This paragraph does not give the Government any right to audit the Contractor’s records. The Contractor shall not be paid for any work performed or costs incurred which reasonably could have been avoided.
(m) Termination for cause. The Government may terminate this contract, or any part hereof, for cause in the event of any default by the Contractor, or if the Contractor fails to comply with any contract terms and conditions, or fails to provide the Government, upon request, with adequate assurances of future performance. In the event of termination for cause, the Government shall not be liable to the Contractor for any amount for supplies or services not accepted, and the Contractor shall be liable to the Government for any and all rights and remedies provided by law. If it is determined that the Government improperly terminated this contract for default, such termination shall be deemed a termination for convenience.
(n) Title. Unless specified elsewhere in this contract, title to items furnished under this contract shall pass to the Government upon acceptance, regardless of when or where the Government takes physical possession.
(o) Warranty. The Contractor warrants and implies that the items delivered hereunder are merchantable and fit for use for the particular purpose described in this contract.
(p) Limitation of liability. Except as otherwise provided by an express warranty, the Contractor will not be liable to the Government for consequential damages resulting from any defect or deficiencies in accepted items.
(q) Other compliances. The Contractor shall comply with all applicable Federal, State and local laws, executive orders, rules and regulations applicable to its performance under this contract.
(r) Compliance with laws unique to Government contracts. The Contractor agrees to comply with 31 U.S.C. 1352 relating to limitations on the use of appropriated funds to influence certain Federal contracts; 18 U.S.C. 431 relating to officials not to benefit; 40 U.S.C. 3701, et seq., Contract Work Hours and Safety Standards Act; 41 U.S.C. 51-58, Anti-Kickback Act of 1986;
41 U.S.C. 265 and 10 U.S.C. 2409 relating to whistleblower protections; 49 U.S.C. 40118, Fly American; and 41 U.S.C. 423 relating to procurement integrity.
(s) Order of precedence. Any inconsistencies in this solicitation or contract shall be resolved by giving precedence in the following order:
(1) The schedule of supplies/services.
(2) The Assignments, Disputes, Payments, Invoice, Other Compliances, and Compliance with Laws Unique to Government Contracts paragraphs of this clause.
(3) The clause at 52.212-5.
(4) Addenda to this solicitation or contract, including any license agreements for computer software.
(5) Solicitation provisions if this is a solicitation.
(6) Other paragraphs of this clause.
(7) The Standard Form 1449.
(8) Other documents, exhibits, and attachments.
(9) The…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .