Demolition Package Drawings.pdf
PDF 11 MB Posted
- Solicitation number
- CDC-120625-60.
- Issued by
- Cameron County, Texas
About this file
These are construction drawings prepared by HDR Engineering, Inc. for the Brownsville Navigation District's Cargo Dock No. 3 Demolition project located in Brownsville, Texas. The comprehensive set of drawings, dated September 2023, includes 14 sheets covering site plans, demolition plans, existing conditions, and technical sections for a complete demolition of the existing cargo dock facility. The drawings detail the systematic removal of various infrastructure elements including concrete decking, piles, rail trestles, utilities, shoreline riprap, and associated structures, with specific instructions for pile extraction, debris management, and site restoration.
The demolition project encompasses a detailed phased approach with specific requirements for material handling, including provisions for salvaging certain items like street and dock signage, and specific instructions for concrete debris removal and storage. The project includes both a base bid and alternate bid option for concrete material processing, with contractors required to remove demolished concrete materials within a 3-mile radius of the project site. Additional technical specifications cover water quality management, pollution prevention, survey requirements, and post-demolition site conditions, with contractors expected to perform detailed surveys and comply with environmental regulations throughout the demolition process.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BROWNSVILLE SHIP CHANNEL
BROWNSVILLE
SHIP
HARBOR
TO BROWNSVILLE
Project No.
10320226
BROWNSVILLE, TEXAS
SEPTEMBER 2023
Brownsville Navigation District
Vicinity Map
Location Map
C o n s t r u c t i o n D r a w i n g s F o r
HDR Engineering, INC TBPELS Firm Registration No. F-754
Cargo Dock No. 3 Demolition
INDEX OF DRAWINGS
SHEET NO. SHEET TITLE
01 COVER SHEET AND INDEX
02 GENERAL NOTES, ABBREVIATIONS, AND LEGEND
03 OVERALL SITE, STAGING & STORAGE PLAN
04 EXISTING DEMO SITE PLAN
05 DOCK FACILITY EXISTING DEMO PLAN (1 OF 2)
06 DOCK FACILITY EXISTING DEMO PLAN (2 OF 2)
07 BELOW DECK EXISTING DEMO PLAN
08 EXISTING DEMO SECTIONS
09 EXISTING CONDITIONS PHOTOS 01
10 EXISTING CONDITIONS PHOTOS 02
11 EXISTING CONDITIONS PHOTOS 03
12 EXISTING CONDITIONS PHOTOS 04
13 EXISTING CONDITIONS PHOTOS 05
14 EXISTING CONDITIONS PHOTOS 06
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P100
AutoCAD SHX Text P100
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BROWNSVILLE
AutoCAD SHX Text
PORT OF
AutoCAD SHX Text
RUSSELLTOWN
AutoCAD SHX Text
BAYVIEW
AutoCAD SHX Text
LAGUNA VISTA
AutoCAD SHX Text
LAGUNA
AutoCAD SHX Text
HEIGHTS
AutoCAD SHX Text
OLMITO
AutoCAD SHX Text
LOS FRESNOS
AutoCAD SHX Text
SAN
AutoCAD SHX Text
LOS INDIOS
AutoCAD SHX Text
ADAMS
AutoCAD SHX Text
GARDENS
AutoCAD SHX Text
FERIA
AutoCAD SHX Text
RANGERVILLE
AutoCAD SHX Text
BLUETOWN
AutoCAD SHX Text G U L F O F M E X I C O
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text L A G U N A M A D R E
AutoCAD SHX Text
PADRE ISLAND
AutoCAD SHX Text
VILLA
AutoCAD SHX Text
NUEVA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HARLINGEN
AutoCAD SHX Text
STUART PLACE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CAMERON
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LAURELES
AutoCAD SHX Text
LA
AutoCAD SHX Text
BENITO
AutoCAD SHX Text
BROWNSVILLE
AutoCAD SHX Text
PORT
AutoCAD SHX Text
ISABEL
AutoCAD SHX Text
MATAMOROS
AutoCAD SHX Text
BROWNSVILLE
AutoCAD SHX Text
PORT OF
AutoCAD SHX Text
HARLINGEN
AutoCAD SHX Text
AutoCAD SHX Text
SHIP CHANNEL
AutoCAD SHX Text R A N C H O
AutoCAD SHX Text V I E J O
AutoCAD SHX Text R E S A C A
AutoCAD SHX Text R A N C H O
AutoCAD SHX Text V I E J O
AutoCAD SHX Text R E S A C A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
INDIANA AVENUE
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
PARKS
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
PROJECT SITE
AutoCAD SHX Text
PROJECT SITE
"ISSUED FOR BID"09/22/2023A
S. A. McCOY
A. VILLARREAL
D. R. BROYLES
02N/A
00G-02.dwg
GENERAL NOTES, ABBREVIATIONS, AND LEGEND
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
RIPRAP (PLAN AND/OR SECTION)
1. THIS IS A STANDARD SHEET SHOWING COMMON
SYMBOLOGY. ALL SYMBOLS ARE NOT NECESSARILY
USED ON THIS PROJECT.
2. SCREENING OR SHADING OF WORK IS USED TO
INDICATE EXISTING COMPONENTS OR TO
DE-EMPHASIZE PROPOSED IMPROVEMENTS TO
HIGHLIGHT SELECTED TRADE WORK. REFER TO
CONTEXT OF EACH SHEET FOR USAGE.
TARGET ELEVATION
KEY NOTE NUMBER
KEY NOTE DESIGNATION
GRANULAR FILL (SECTION)
EARTH (SECTION)
GENERAL NOTES:
PLAN TITLE
GENERAL SYMBOLOGY
MATERIALS IN PLAN/SECTION
SHEET WHERE DETAIL
IS LOCATED *
DETAIL NUMBER
SHEET WHERE SECTION
VIEW IS FIRST CUT *
SECTION LETTER
SHEET WHERE SECTION
IS LOCATED
SECTION LETTER
FLAG INDICATES DIRECTION
OF SECTION CUT
ELEVATION NUMBER
ARROW INDICATES
POINT OF VIEW
SECTION CUT MARKER
DETAIL MARKER
SHEET WHERE ELEVATION
IS LOCATED *
SINGLE ELEVATION OR PHOTO MARKER
SECTION TITLE
* EXCEPTIONS WHERE THE SHEET NUMBER IS REPLACED BY A DASH (-).
1) FOR COMMON DETAILS, SECTIONS, ELEVATIONS OR DETAILS THAT
ARE CUT OR CALLED OUT ON MULTIPLE SHEETS.
2) SECTIONS, ELEVATIONS OR DETAILS THAT ARE LOCATED ON THE
SAME SHEET THEY ARE CUT OR CALLED OUT ON.
FOR REFERENCING DETAILS INCLUDED IN DRAWING SET.
PLAN
1/4" = 1'-0"
X
XXX
X
XXX
SECTION
3/8" = 1'-0"
XXX
X
XXX
X
XXX
INTERIOR EXTERIOR
ARROW INDICATES
DIRECTION OF
PLAN NORTH
NORTH ARROW
1. THESE ABBREVIATIONS APPLY TO THE ENTIRE SET
OF CONTRACT DRAWINGS.
2. LISTING OF ABBREVIATIONS DOES NOT IMPLY THAT
ALL ABBREVIATIONS ARE USED IN THE CONTRACT
DRAWINGS.
3. ABBREVIATIONS SHOWN ON THIS SHEET INCLUDE
VARIATIONS OF A WORD. FOR EXAMPLE, "MOD" MAY
MEAN MODIFY OR MODIFICATION; "INC" MAY MEAN
INCLUDED OR INCLUDING AND "REINF" MAY MEAN
EITHER REINFORCE OR REINFORCING.
ABBREVIATION NOTES:
COLUMN GRID LINE/CENTERLINE
GENERAL LINE SYMBOLOGYABBREVIATIONS (CONTINUED)
FIG
FN
FOC
FT
GALV
GEN
GND
GR
GVL
HORIZ
HT
IN
INC
JT
LF
LG
LIN
LOC
MAINT
MATL
MAX
MECH
MH
MIN
MIR
MISC
MON
N
NA
NIC
NTS
FIGURE
FENCE
FACE OF CONCRETE,
FACE OF CURB
FEET, FOOT
GALVANIZED
GENERAL
GROUND
GRADE
GRAVEL
HORIZONTAL
HEIGHT
INCH
INCLUDE
JOINT
LINEAR FOOT
LONG
LINEAR
LOCATION
MAINTENANCE
MATERIAL
MAXIMUM
MECHANICAL
MANHOLE
MINIMUM
MIRROR
MISCELLANEOUS
MONUMENT
NORTH
NOT APPLICABLE
NOT IN CONTRACT
NOT TO SCALE
ABAN
ADJ
AGGR
ALIG
AP
APRX
AVE
BLDG
BOT
BTW
C TO C
CE
CI
CL
CLR
COMM
CONC
CONN
CONT
CTR
CVT
DEMO
DET
DIA
DIFF
DIM
DWG
EA
EJ
EL
EMBD
ENTR
EOP
EQ
EQUIP
EQUIV
EXC
EXP
EXST
ABANDON
ADJUSTABLE, ADJACENT
AGGREGATE
ALIGNMENT
ACCESS PANEL
APPROXIMATE
AVENUE
BUILDING
BOTTOM
BETWEEN
CENTER TO CENTER
CONCRETE EDGE
CURB INLET
CENTERLINE
CLEAR
COMMUNICATION
CONCRETE
CONNECTION
CONTINUOUS
CENTER
CULVERT
DEMOLITION
DETAIL
DIAMETER
DIFFERENTIAL, DIFFERENCE
DIMENSION
DRAWING
EACH
EXPANSION JOINT
ELEVATION
EMBEDDED
ENTRANCE
EDGE OF PAVEMENT
EQUAL
EQUIPMENT
EQUIVALENT
EXCAVATION
EXPANSION, EXPOSED
EXISTING
EXISTING FENCEX X X
RAILROAD
PROPERTY LINE
BOTTOM OF DITCH
EASEMENT
LIMITS OF CONSTRUCTION
ROW
SILT FENCE
TOE OF SLOPE
TOP OF SLOPE
HIGHWAY GUARDRAIL
LEVEE TOP
LEVEE TOE
FENCE - WOOD
GENERAL NOTES
GENERAL REQUIREMENTS:
1. THE DETAILED REQUIREMENTS FOR ALL ITEMS DESCRIBED IN THE GENERAL NOTES
ARE CONTAINED IN THE SPECIFICATIONS.
2. CONTRACTOR SHALL NOT COMMENCE ANY DEMOLITION OPERATION UNTIL THE
CONTRACTOR HAS VERIFIED THAT DEMOLITION / ENVIRONMENTAL PERMITS FOR THIS
PROJECT HAVE BEEN ACQUIRED.
3. DEMOLITION WORK SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES
AND STANDARDS, THE PROJECT SPECIFICATIONS AND PROJECT DRAWINGS.
CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY OF ANY CONFLICTS BETWEEN
STATE AND LOCAL CODES, PROJECT SPECIFICATIONS AND PROJECT DRAWINGS
PRIOR TO ANY DEMOLITION.
4. CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL ELEVATIONS, COORDINATES,
DIMENSIONS, EXISTING CONDITIONS, AND INFORMATION INDICATED ON THE
CONTRACT DOCUMENTS PRIOR TO COMMENCEMENT OF SITE WORK. THE OWNER
SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES FOUND ON THE CONTRACT
DOCUMENTS OR FOUND TO EXIST BETWEEN THE FIELD CONDITIONS AND THE
CONTRACT DOCUMENTS. THE CONTRACTOR SHALL TAKE CORRECTIVE ACTION AS
DIRECTED BY THE OWNER.
5. CONTRACTOR SHALL UTILIZE BEST MANAGEMENT PRACTICES THROUGHOUT THE
DURATION OF THE PROJECT. COMPLY WITH TEMPORARY ENVIRONMENTAL AND
STORM WATER POLLUTION REQUIREMENTS PROVIDED BY OWNER.
6. THE LOCATION AND DEPTH OF UTILITIES SHOWN ARE APPROXIMATE AND SHALL BE
VERIFIED BY THE CONTRACTOR BEFORE WORK COMMENCES. PRIOR TO BEGINNING
ANY EXCAVATION WORK IN THE AREA OF EXISTING UTILITIES, THE CONTRACTOR
SHALL CONTACT THE OWNER FOR EXACT LOCATIONS AND DEPTHS TO PREVENT ANY
DAMAGE OR INTERFERENCE WITH PRESENT FACILITIES.
7. THE CONTRACTOR SHALL NOTIFY THE TEXAS ONE CALL (811) AND ALL KNOWN UTILITY
OWNERS WITHIN THE WORK AREA AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION,
PILING OR OTHER FOUNDATION DEMOLITION OPERATIONS. THIS ACTION HOWEVER,
SHALL IN NO WAY BE INTERPRETED AS RELIEVING THE CONTRACTOR OF THE
RESPONSIBILITY UNDER THE TERMS OF THE CONTRACT AS SET OUT IN THE PLANS
AND SPECIFICATIONS. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY HIS
OPERATIONS AT HIS OWN EXPENSE AND TO THE SATISFACTION OF THE UTILITY
COMPANY INVOLVED.
8. CONTRACTOR SHALL COORDINATE WITH THE OWNER AND PROVIDE AND MAINTAIN
ALL TRAFFIC CONTROL DEVICES DURING THE COURSE OF THE CONSTRUCTION
PERIOD.
9. CONTRACTOR TO COORDINATE WITH LOCAL PILOT AND PORT OF BROWNSVILLE ON
MARINE TRAFFIC/MOVEMENTS SCHEDULES WHICH MAY AFFECT DEMOLITION. NOTE
THAT SHIP MOVEMENTS MAY CAUSE TEMPORARY CURRENT/WAKES THAT AFFECT
MARINE ACTIVITIES.
10. CONTRACTOR SHALL MAINTAIN ALL REGULATORY AND WARNING SIGNS DURING THE
DEMOLITION PERIOD.
11. CONTRACTOR SHALL CONDUCT HIS OPERATIONS SO AS TO NOT INTERFERE WITH, OR
BE DETRIMENTAL TO VESSEL AND VEHICULAR TRAFFIC AND THE DAILY OPERATION
OF THE OWNER DURING THE COURSE OF THE WORK.
12. ALL EXISTING FEATURES OF THE PROJECT SITE TO REMAIN WHICH ARE DAMAGED BY
THE CONTRACTOR DURING HIS OPERATIONS SHALL BE REPAIRED AT THE
CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER.
13. WORKER SAFETY IN EXCAVATIONS AND TRENCHES SHALL BE PROVIDED BY THE
CONTRACTOR IN ACCORDANCE WITH OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION (OSHA) STANDARDS, 29 CFR 1926, SUBPART P - EXCAVATIONS,
TRENCHING, AND SHORING. CONTRACTOR SHALL ALSO COMPLY WITH ALL
APPLICABLE STATE AND LOCAL REQUIREMENTS. A COPY OF THE GEOTECHNICAL
REPORT CAN BE OBTAINED FROM THE OWNER FOR USE BY THE CONTRACTOR IN THE
DESIGN OF ANY TRENCH SAFETY SYSTEM(S).
14. CONTRACTOR, SUBCONTRACTORS AND OTHER CONTRACTED ENTITIES SHALL
SUCCESSFULLY COMPLETE ALL THE TRAINING COURSES AND REQUIREMENTS
REQUIRED BY OWNER IN ORDER TO ACCESS THE PROJECT SITE AND CARRY OUT THE
CONTRACTED WORK. CONTRACTOR SHALL POSSESS ALL THE REQUIRED
IDENTIFICATION DOCUMENTS AND SHALL ACCESS THE PROJECT SITE THROUGH
OWNER SECURITY CHECK POINT AND FOLLOW OWNER'S CHECK-IN/-OUT PROCEDURE
ON A DAILY BASIS. THE IDENTIFICATION DOCUMENTS INCLUDE, AS A MINIMUM, VALID
TRANSPORTATION WORKER IDENTIFICATION CREDENTIAL (TWIC®) CARD AND VALID
DRIVER'S LICENSE.
15. CONTACT OWNER FOR TRAINING INFORMATION, ACCESS AND PARKING
REQUIREMENTS:
16. HARBOR MASTER OFFICE, (956) 831-8256 / MARINE VHF RADIO CHANNEL 16
HORIZONTAL AND VERTICAL CONTROL:
1. TOPOGRAPHIC SURVEY WAS PERFORMED BY MEJIA AND ROSE, INC., DATED
OCTOBER 11, 2021.
2. BATHYMETRIC SURVEY DATA IS BASED ON NAISMITH MARINE SERVICES SURVEY
DATED JANUARY 22, 2021.
3. COORDINATES SHOWN ARE STATE PLANE GRID, TEXAS SOUTH ZONE, NAD' 83 IN U.S.
FEET.
4. ALL ELEVATIONS SHOWN REFER TO NORTH AMERICAN VERTICAL DATUM, 1988 (NAVD
'88).
5. MONUMENT USED FOR HORIZONTAL AND VERTICAL CONTROL IS AS FOLLOWS:
"CP1" (535 R/L 1948 89+679.68)
N 16,509,591.45' E 1,344,712.65'
EL. +13.8' NAVD88 (+15.0' MLT)
REFERENCE MONUMENT "ZIMCO"
N 16,518,058.49' E 1,366,219.45'
EL. +6.6' NAVD88
ELEVATION IDENTIFICATION
NUMBER
SHEET WHERE POINT OF VIEW
MARKER CAN BE FOUND *
ELEVATION TITLE
DETAIL TITLE
X
XXX
DETAIL
1/4" = 1'-0"
SHEET WHERE DETAIL
IS LOCATED *
DETAIL NUMBER
X
XXX
ELEVATION
3" = 1'-0"
A ED H J Q
4 6
ABBREVIATIONS
TBM
TEMP
TOC
TOPO
TRANS
TRD
TYP
UNO
UTIL
VIF
W/ W/O
WTHP
TEMPORARY BENCHMARK
TEMPORARY
TOP OF CURB, TOP OF CONCRETE
TOPOGRAPHY
TRANSITION
TRENCH DRAIN
TYPICAL
UNLESS NOTED OTHERWISE
UTILITY
VERIFY IN FIELD
WITH
WITHOUT
WORKING POINT
OAL
OH
OPNG
OPP
NIC
PED
PL
PRELIM
PROP
PT
PVC
PVMT
QTY
R&S
REF
REINF
REM
REQD
REV
RND
ROW
RR
SCH
SECT
SEP
SHT
SIM
SL
SOG
SPA
SPEC
ST
STA
STD
STL
STOR
OUTSIDE DIAMETER
OVERHEAD
OPENING
OPPOSITE
NOT IN CONTRACT
PEDESTAL
PLATE, PROPERTY LINE,
PRELIMINARY
PROPERTY, PROPOSED
POINT
POLYVINYL CHLORIDE
PAVEMENT
QUANTITY
REMOVE AND SALVAGE
REFERENCE
REINFORCING
REMOVE
REQUIRED
REVISION
ROUND
RIGHT-OF-WAY
RAILROAD
SCHEDULE
SECTION
SEPARATE
SHEET
SIMILAR
SLOPE
SLAB ON GRADE
SPACING
SPECIFICATION
STREET
STATION
STANDARD
STEEL
STORAGE
WATER LEVEL
DATUM (FT)
NAVD 88 USACE MLLW USACE MLT
MEAN HIGHER HIGH WATER (MHHW) +0.35 +1.50 +1.55
MEAN LOWER LOW WATER (MLLW) -1.15 0.0 +0.05
NORTH AMERICAN VERTICAL
DATUM (NAVD88) 0.0 +1.15 +1.20
USACE MEAN LOW TIDE (MLT) -1.20 -0.05 0.0
HORIZONTAL AND VERTICAL CONTROL (CONTINUED):
1. DATUM CORRELATION TABLE:
TIDAL DATA SHOWN IS BASED ON VDATUM, AN ONLINE TOOL DEVELOPED JOINTLY BY
NOAA'S (NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION) NATIONAL
GEODETIC SURVEY (NGS), OFFICE OF COAST SURVEY (OCS), AND CENTER FOR
OPERATIONAL OCEANOGRAPHIC PRODUCTS AND SERVICES (CO-OPS).
WATER SURFACE ELEVATIONS AND WAVE HEIGHTS AT THE SITE WILL BE AFFECTED BY
RAINFALL, WIND DIRECTION, VELOCITY AND DURATION, CHANNEL TRAFFIC, AND DAILY
TIDAL FLUCTUATIONS. TROPICAL WEATHER EVENTS, SUCH AS TROPICAL STORMS AND
HURRICANES, CAN GREATLY AFFECT BOTH WATER SURFACE ELEVATIONS AND WAVE
HEIGHTS.
DEMOLITION SEQUENCE:
THE DEMOLITION SEQUENCE IS AS FOLLOWS:
1. DEMOLISH WATERSIDE DOCK SUPERSTRUCTURE OVER PILE ROWS A-H AND THE
ENTIRE LENGTH OF THE RAIL TRESTLE SUPERSTRUCTURE.
2. FULLY EXTRACT DOCK PILES FOR ROWS A-D AND TRESTLE PILES FOR COLUMN T1.
THEN CUT REMAINING DOCK AND TRESTLE PILES AT THE MUDLINE AND REMOVE.
3. TERMINATE WATER, ELECTRICAL, AND SEWER ON PORTIONS TO BE DEMILISHED AND
REMOVE DOCK HOUSE AND POLES ON LANDSIDE FOUNDATION.
4. DEMOLISH ELEVATED LANDSIDE PLATFORM AND EXCAVATE DOWN TO REMOVE
EXISTING RETAINING WALL.
5. DEMOLISH THE REMAINING DOCK SUPERSTRUCTURE.
6. REMOVE THE EXISTING RIP RAP AND STORE ON SITE AS DIRECTED BY OWNER.
7. CUT OFF PILES ON ROWS J-Q AT MUDLINE.
8. REMOVE AND CLEAR ALL DEBRIS FROM THE MUDLINE.
9. DEMOLISH LANDSIDE FACILITIES AND FEATURES AS SHOWN ON DRAWINGS.
THE CONSTRUCTION SEQUENCE ABOVE IS GENERAL IN NATURE. THE CONTRACTOR HAS
THE OPTION OF PROPOSING AN ALTERNATIVE CONSTRUCTION SEQUENCE. THE
CONTRACTOR SHALL SUBMIT HIS ALTERNATIVE CONSTRUCTION SEQUENCE TO THE
OWNER FOR REVIEW PRIOR TO CONSTRUCTION.
PROJECT CONSTRUCTION VIBRATION MONITORING :
1. THE CONSTRUCTION WORK FOR THIS PROJECT WILL PRODUCE VIBRATIONS WHICH
MAY EFFECT NEARBY EXISTING STRUCTURES, EARTHEN BERMS AND/OR SLOPE
TERRAIN. THE CONTRACTOR IS REQUIRED TO MONITOR THE VIBRATIONS ON EXISTING
ELEMENTS WHICH MAY BE AFFECTED ACCORDING TO PROJECT SPECIFICATION 02 22
13 CONSTRUCTION VIBRATION MONITORING.
DEMOLITION AND SALVAGE:
1. THE CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL EXISTING LANDSIDE,
WATERSIDE, AND SUBMERGED STRUCTURES ON THE SITE AS SHOWN ON THE
DRAWINGS. THE APPROXIMATE LOCATION AND EXTENT OF THESE STRUCTURES HAVE
BEEN SHOWN ON THE DRAWINGS.
2. NOTIFY THE HARBOR MASTER, PORT OF BROWNSVILLE SECURITY, AND THE UNITED
STATES COAST GUARD PRIOR TO COMMENCING WATERSIDE DEMOLITION WORK.
3. COORDINATE AND SCHEDULE ALL DEMOLITION WITH THE OWNER AND
HARBORMASTER TO CAUSE MINIMAL INTERRUPTION TO MARINE TRAFFIC AND
MAINTAIN COORDINATION THROUGHOUT THE WATERSIDE DEMOLITION WORK.
4. DEMOLITION OF EXISTING FACILITIES, UNLESS NOTED OTHERWISE, SHALL BECOME
THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF LEGALLY AND
PROPERLY.
5. ALL TIMBER, CONCRETE, STEEL AND OTHER DEBRIS SHALL BE HAULED OFF SITE AND
DISPOSED OF AT THE CONTRACTOR'S EXPENSE.
6. EXCAVATED SOIL AND ROCK SHALL BE DISPOSED OF AS DIRECTED BY OWNER AT THE
EXPENSE OF THE CONTRACTOR.
7. CONCRETE DECKING SHOULD BE REMOVED IN MANAGEABLE SECTIONS. ANY
CONCRETE DROPPED OVERBOARD SHALL BE RETRIEVED AND DISPOSED OF
PROPERLY.
DEMOLITION AND SALVAGE (CONTINUED):
8. MATERIALS TO BE SALVAGED FOR THE OWNER'S USE ARE AS FOLLOWS:
A. STREET AND DOCK SIGNAGE
B. SHORELINE RIP-RAP
C1. BASE BID: EXCLUDING SHORELINE RIPRAP, CONTRACTOR TO REMOVE ALL DEMOLISHED
CONCRETE MATERIALS/DEBRIS (REGARDLESS OF SIZE) FROM DOCK AND TRANSPORT TO
STORAGE WITHIN 3 MILE RADIUS FROM PROJECT SITE. NO PROTRUDING STEEL
REINFORCEMENT IS TO REMAIN IN STORED CONCRETE DEBRIS MEASURING LESS THEN 8
INCHES IN ANY DIMENSION.
C2. ALTERNATE BID: AT THE STORAGE SITE FOR REMOVED CONCRETE MATERIALS, CONTRACTOR
TO CUT DOWN CONCRETE TO MAXIMUM 36" DIMENSION AND CUT/REMOVE AND DISPOSE
PROTRUDING REINFORCEMENT FLUSH WITH CONCRETE EDGES.
9. MATERIALS TO BE SALVAGED SHALL BE STOCKPILED IN THE AREA AS DIRECTED BY. STOCKPILED
MATERIALS SHALL BE PLACED ON TIMBER SLEEPERS A MINIMUM OF 4-INCH ABOVE GROUND
SURFACE AND SHALL BE ADEQUATELY SUPPORTED UNLESS OTHER STORAGE METHOD IS
PRE-APPROVED BY OWNER.
10. ALL VISIBLE PILING HAVE BEEN SHOWN. IT IS POSSIBLE THAT THERE ARE PILES BROKEN OFF
BELOW THE WATER AND/OR GROUND SURFACE AND/OR MUDLINE THAT ARE NOT VISIBLE.
CONTRACTOR TO NOTIFY OWNER AND PROCEED AS DIRECTED. CONTRACTOR SHALL COMPLY WITH
ALL WATER QUALITY AND POLLUTION PREVENTION REGULATIONS, INCLUDING USE OF SILT
CURTAINS AND FLOATING BOOMS.
11. PILING SHALL NOT BE FULLY EXTRACTED UNLESS SHOWN OTHERWISE ON THE DRAWINGS OR
SPECIFIC WRITTEN PERMISSION OF THE OWNER IS PROVIDED TO CONTRACTOR.
12. JETTING EXTRACTION METHODS FOR PILE REMOVAL ARE NOT ALLOWED UNLESS NOTED OR
APPROVED OTHERWISE IN WRITING BY OWNER.
13. CONTRACTOR SHALL PERFORM A POST-DEMOLITION DIVE SURVEY TO CONFIRM THAT ALL
SUBMERGED STRUCTURES/DEBRIS HAVE BEEN REMOVED WITHIN THE WORK LIMITS. SUBMIT THE
DIVE REPORT FOR ACCEPTANCE BY THE OWNER. REFER TO SPECIFICATION 02 41 00 - DEMOLITION
FOR ADDITIONAL REQUIREMENTS INCLUDING THE PERFORMANCE OF BATHYMETRIC SURVEY.
14. ALL CONFIRMATION SURVEYS AND TESTS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. IF SUBMITTALS DO NOT INDICATE WORK HAS BEEN SUCCESSFULLY COMPLETED, CONTRACTOR SHALL
BE RESPONSIBLE FOR COSTS AND PERFORMANCE OF ALL SUBSEQUENT TEST AND SURVEYS.
SITE WORK / EARTHWORK:
1. AREAS TO SERVE AS STORAGE AND/OR LAYDOWN SHALL BE CLEARED TO REMOVE ALL
VEGETATION.
2. TRANSITIONS IN GRADES DUE TO EXCAVATION AND DEMOLITION WORKS SHALL BE SMOOTH AND
UNIFORM.
3. THE AREA SURROUNDING THE CONCRETE PAVING AND WORK LIMITS SHALL BE GRADED IN SUCH A
MANNER THAT RAINWATER DOES NOT POND WITHIN THE WORK LIMITS. RUNOFF SHALL BE
DIVERTED AROUND THE PROJECT LIMITS BY MEANS OF PROPER GRADING.
4. EROSION CONTROL AND STABILIZATION MEASURES SHALL BE UTILIZED UPON RESTORATION OF
DISTURBED AREAS AT AND AROUND RAIL TRESTLE AND INTERNATIONAL SEAFARER CENTER.
MEASURES CAN INCLUDE SEEDING WITH MATS AND SODDING.
REFERENCE DATA:
1. HDR REPORT “GEOTECHNICAL ANALYSES AND RECOMMENDATIONS REPORT, CARGO DOCK 3
PHASE 1 DESIGN, BROWNSVILLE NAVIGATION DISTRICT, BROWNSVILLE, TX, DECEMBER 22, 2021.”
2. ORIGINAL DESIGN DRAWINGS OF CARGO DOCK 3 IN SPECIFICATION 02 41 00.
3. TOPOGRAPHIC SURVEY PERFORMED BY MEJIA AND ROSE, INCORPORATED DATED OCTOBER 11, 2021 IN SPECIFICATION 02 41 00.
4. DIVE REPORT “BROWNSVILLE NAVIGATION DISTRICT CARGO DOCK #3, DEBRIS REPORT”
CONDUCTED BY INDEPTH DIVING SERVICES LLC. ON OCTOBER 19, 2021 IN SPECIFICATION 02 41 00.
© 2022 Microsoft Corporation © 2022 Maxar ©CNES (2022) Distribution Airbus DS
864+00
865+00
866+00
867+00
868+00
869+00
870+00
871+00
872+00
873+00
874+00
875+00
876+00
877+00
878+00
879+00
880+00
881+00
882+00
883+00
884+00
885+00
886+00
887+00
888+00
889+00
890+00
891+00
892+00
893+00
894+00
895+00
BROWNVILLE SHIP CHANNEL ALIGNMENT
CARG
O
DO
CK 3
CHANNEL LIMIT
STAGING AND
REMOVED RIPRAP
STORAGE AREA
W
INDHAUS RD
R. L. OSTOS RD
M
IL
O R
D
N INDIANA AVE
FOUST RD
M
IN
ER
AL
L O
O P
CARGO DOCK 4
CARGO DOCK 1
CARGO DOCK 2
PATIO 2-7
CARGO DOCK 7
CARGO DOCK 8
CARGO DOCK 11
C
AR
G O
D O
C K
PYRAMID YARD
U. S. CUSTOMS AND
HARBOR MASTER BUILDING
INTERNATIONAL
SEAFARER CENTER
DAVID SHOR RD
CP1
N: 16509591.45' E: 1344712.65'
A. VILLARREAL
D. R. BROYLES
031" = 200'
00G-03.dwg
OVERALL SITE, STAGING & STORAGE PLAN
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
OVERALL SITE, STAGING & STORAGE PLAN
1" = 200'
W
© 2022 Microsoft Corporation © 2022 Maxar ©CNES (2022) Distribution Airbus DS
E E
E E
E E
E
E E
E E
E E
E E
E E
E E
E
X X
X X
X X
X
XXXXXX
X
X
X
X
X
X
X
X
X X
E
E
E
E
E
E
E
E
E
E
E
E E
E E
E E
E E
X X
X X
X X
XXXXXXXXXXXXXXXXXXXXXX
X X
X X
X
X
X
892+00
893+00
894+00
895+00
BR
O
W N
VI
LL
E
SH
IP
C
H
AN
N
EL
A
LI
G N
M
EN
T
CARGO
DOCK 3
CHANNEL LIMIT
BOAT SLIP AND
WOOD DOCKS
RAIL SPUR
RAIL SPUR
WINDHAUS RD
R . L
. O
ST
O S
R D
U. S. CUSTOMS AND
HARBOR MASTER BUILDING
INTERNATIONAL
SEAFARER CENTER
-26 -30
-34 -36
-38
-38
-38 -38
-3
-38
-38
-36 -34 -30
"ISSUED FOR BID"09/22/2023 A
A. VILLARREAL
D. R. BROYLES
041" = 60'
00X-01.dwg
EXISTING DEMO SITE PLAN
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
EXISTING DEMO SITE PLAN
1" = 60'
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X
X X
X X
X X
X X
X X
X X
X
XX
X X
X X
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD SD
W W W W W W W W W W W W W W W
W W
W W
W
W W W W W W
W W
W W
W W
W
W
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
UGE
UGE
ASPHALT DRIVE
WINDHAUS RD
INTERNATIONAL
SEAFARER CENTER
BROWNSVILLE NAVIGATIONAL CHANNEL
WATER SIDE DOCK EDGE
MOORING CLEAT, TYP
REMOVE RECESSED RAIL
RAIL TRESTLE
(SEE NOTE 1)
SALVAGE
DOCK SIGN
REMOVE RAILING
REMOVE
CONCRETE STEPS
FLAG POLE
AND LIGHT
(SEE NOTE 8)
ELECTRICAL
BOX TO REMAIN
LIGHT POLE
TO REMAIN
END OF
DRIVE
GRATE INLET
TO REMAIN
RAIL, TYP
(SEE NOTE 2)
CHAINLINK FENCE
(SEE NOTE 8) EDGE OF ASHPALT ROAD
TO REMAIN
6.9' X 9.5'
RESTROOM
TO BE REMOVED
DRAIN
TO REMAIN
REMOVE
CONCRETE RAMP
WATER METER
AND VALVES
(SEE NOTE 6)
GATE NO. 1
(SEE NOTE 8)
CONCRETE BASE
EDGE OF
CONCRETE PAVING
WATER METER, VALVES AND
CLEANOUTS (SEE NOTE 5)
RAILROAD
CROSSING SIGN
TO REMAIN
LIGHT POLE
TO REMAIN, TYP
CHAINLINK FENCE
(SEE NOTE 8)
CONCRETE PIPE
TO REMAIN
FULLY REMOVE
WOOD POSTS, TYP
(5 EACH)
EXISTING RIP RAP
TO REMAIN
(SEE NOTE 3)
SANITARY LIFT
STATION AND FENCE
TO REMAIN
GATE NO. 2
(SEE NOTE 8)
SALVAGE
STREET SIGN
REMOVE
CONCRETE DOCK
GATE NO. 3
(SEE NOTE 8)
5 6 7
18 19 20 21
SS
SS SS SS SS SS
ELECTRICAL
UTILITIES
(SEE NOTE 7)
EXPANSION JOINT/EDGE OF PILE
SUPPORTED CONCRETE DOCK
UNDERGROUND/UNDER DOCK
UTILITIES TO BE DEMOLISHED
(VERIFY ROUTING IN FIELD)
LIGHT POLE
TO BE DEMOLISHED
EDGE OF CONCRETE
DECKING / PAVING
REMOVE
CONCRETE DECK
REMOVE DIRT RAMP
REMOVE
SHORELINE RIPRAP
20 FEET BEYOND
END OF DOCK
DOCK LENGTH 441.5'TRESTLE LENGTH 237.5'
SHORELINE
(APRX)
11' NORTH OF
EXISTING DOCK
SAW CUT AND
REMOVE PAVEMENT
PARKING LOT
TO REMAIN
WOOD POSTS
TO REMAIN, TYP
(9 EACH)
EXISTING STORM
CONCRETE PIPE
DRAIN BELOW DECK
( SEE NOTE 9)
A. VILLARREAL
D. R. BROYLES
051" = 20'
00X-02.dwg
DOCK FACILITY EXISTING DEMO PLAN (1 OF 2)
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
DEMOLITION LEGEND/NOTES:
DEMOLISH/REMOVE FEATURES
PHOTOGRAPH OF EXISTING CONDITION,
SEE SHEETS 07 THROUGH 14
1. THE RAIL TRESTLE SHALL BE FULLY DEMOLISHED
TO LIMITS SHOWN. SEE BELOW DECK
DEMOLITION DETAILS FOR PILE REMOVAL.
2. EXISTING RAIL SYSTEM TO BE REMOVED AND
REPLACED BY OTHERS (NIC).
3. ALL RIP RAP TO REMAIN EXCEPT WHERE NOTED.
REMOVE ALL RIP RAP BELOW EXISTING PILE
SUPPORTED DOCK AND AS REQUIRED TO
EXTRACT PILES.
4. POWER UTILITIES TO BE TERMINATED AND
REROUTED BY THE PORT AND PUB.
5. THE ROUTING FOR THESE UTILITIES IS
UNKNOWN. CONTRACTOR TO VERIFY AND
PERFORM WORK WITH CAUTION.
6. UTILITY ROUTING FOR VALVES TO BE CUT AND
CAPPED ON DOWNSTREAM SIDE OF METER.
VALVES AND METER TO REMAIN.
7. ELECTRICAL UTILITY ROUTING UNKNOWN.
CONTRACTOR TO COORDINATE WITH PORT AND
PUB TO DE-ENERGIZE, CAP AND REMOVE OR
RE-ROUTE OUTSIDE THE PROJECT AREA.
8. TO BE REMOVED AND SALVAGED BY OTHERS
(NIC).
9. EXISTING STORM DRAIN CONCRETE PIPE BELOW
DECK TO BE REMOVED UP TO THE EAST SIDE OF
PROPOSED LANDSIDE PLATFORM. COORDINATE
WITH DOCK DESIGN DRAWINGS AND OWNER.
REMAINING LENGTH OF PIPE WILL BE REMOVED
DURING NEW DOCK CONSTRUCTION PROJECT.
DOCK FACILITY EXISTING/DEMO PLAN
1" = 20'
M
AT
C H
L
IN
E
SE
E
SH
EE
T
A
B
C
E E
E E
E E
E E
E E
E E
E E
E
E
E
X X
X X
X X
X X
X
XXXXXXXXXXXXXXX
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
CALICHE AREA
WINDHAUS RD
DOCK ANCHOR, TYP
CHAINLINK FENCE
(SEE NOTE 8)
EDGE OF ASHPALT ROAD
TO REMAIN
GRATE INLET
WITH CONCRETE BASE
TO REMAIN
REMOVE
PANEL BOX
(SEE NOTE 8)REMOVE WOOD
POSTS
LIGHT POLE
TO REMAIN, TYP
RAIL BLOCK
TO REMAIN
CALICHE EDGE
OVERHEAD
POWER LINE
(SEE NOTE 4)
REMOVE
CODE BOX
(SEE NOTE 8)
FULLY REMOVE
TIMBER POLE CLUSTER
REMOVE
SHORELINE RIPRAP
20 FEET BEYOND
END OF DOCK
WOOD DOCKS FOR
BOAT SLIP TO REMAIN
PAVERS TO REMAIN
CONCRETE
BOAT RAMP
TO REMAIN
GRATE INLET
WITH CONCRETE BASE
TO REMAIN
REMOVE
FIRE DEPT.
CONNECTION
(SEE NOTE 5)
BROWNSVILLE NAVIGATIONAL CHANNEL
REMOVE
CONCRETE DOCK
WATER SIDE DOCK EDGE
MOORING CLEAT, TYP
REMOVE RECESSED RAIL
STREET SIGN
(SEE NOTE 8)
RAIL, TYP
(SEE NOTE 2)
REMOVE
LIGHT POLE
(SEE NOTE 8)
GATE NO. 4
(SEE NOTE 8)
CHAINLINK FENCE
(SEE NOTE 8)
CALICHE EDGE
POWER POLE, TYP
(SEE NOTE 4)
8 9 10
32 33 34
REMOVE
POWER POLE
WITH CONDUIT
AND GUY ANCHOR
(SEE NOTE 4)
PVC PIPES
(SEE NOTE 5)
REMOVE
CONCRETE WALLS
AND CALICHE RAMP
REMOVE RAILING, TYP
EXPANSION JOINT/EDGE OF PILE
SUPPORTED CONCRETE DOCK
EDGE OF CONCRETE
DECKING / PAVING
REMOVE
CONCRETE DECK
REMOVE BRUSH AND
TAP ROOTS
REFLECTOR
TO REMAIN
DOCK LENGTH 441.5'
SHORELINE
(APRX)
CUT OFF TIMBER POLE
CLUSTER BELOW
EXISTING GRADE
APRON AND
CULVERT PIPE
TO REMAIN
A. VILLARREAL
D. R. BROYLES
061" = 20'
00X-03.dwg
DOCK FACILITY EXISTING DEMO PLAN (2 OF 2)
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
DOCK FACILITY EXISTING/DEMO PLAN
1" = 20'
M
AT
C H
L
IN
E
SE
E
SH
EE
T
DEMOLITION LEGEND/NOTES:
DEMOLISH/REMOVE FEATURES
PHOTOGRAPH OF EXISTING CONDITION,
SEE SHEETS 07 THROUGH 14
1. THE RAIL TRESTLE SHALL BE FULLY DEMOLISHED
TO LIMITS SHOWN. SEE BELOW DECK
DEMOLITION DETAILS FOR PILE REMOVAL.
2. EXISTING RAIL SYSTEM TO BE REMOVED AND
REPLACED BY OTHERS (NIC).
3. ALL RIP RAP TO REMAIN EXCEPT WHERE NOTED.
REMOVE ALL RIP RAP BELOW EXISTING PILE
SUPPORTED DOCK AND AS REQUIRED TO
EXTRACT PILES.
4. POWER UTILITIES TO BE TERMINATED AND
REROUTED BY THE PORT AND PUB.
5. THE ROUTING FOR THESE UTILITIES IS
UNKNOWN. CONTRACTOR TO VERIFY AND
PERFORM WORK WITH CAUTION.
6. UTILITY ROUTING FOR VALVES TO BE CUT AND
CAPPED ON DOWNSTREAM SIDE OF METER.
VALVES AND METER TO REMAIN.
7. ELECTRICAL UTILITY ROUTING UNKNOWN.
CONTRACTOR TO COORDINATE WITH PORT AND
PUB TO DE-ENERGIZE, CAP AND REMOVE OR
RE-ROUTE OUTSIDE THE PROJECT AREA.
8. TO BE REMOVED AND SALVAGED BY OTHERS
(NIC).
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
123456789101112131415161718192021222324252627282930313233343536373839404142434445
BROWNSVILLE NAVIGATION CHANNEL
CARGO DOCK NO. 3
LANDSIDE DOCK AREA
T3T4
TC
TB
TA
TD
RAIL TRESTLE PILES DOCK PILES
10', TYP
2.7' (VIF)
8.75'
Q P O
M
K
J
D C
B A
L
N
H
G F E
9'
T1T2
535455
252627
FULLY EXTRACT 16" SQUARE CONCRETE PILES
AT EXISTING GRADE MUDLINE AND REMOVE
(GRID A TO GRID D - 178 EACH)
CUT 16" SQUARE CONCRETE PILES
AT EXISTING GRADE MUDLINE AND REMOVE
(GRID E TO Q - 430 EACH)
FULLY EXTRACT 16" SQUARE
CONCRETE PILES AT GRID T1
RAIL TRESTLE. (4) TOTAL
EXISTING STORM DRAIN CONCRETE PIPE BELOW
DECK TO BE REMOVED UP TO THE EAST SIDE OF
PROPOSED LANDSIDE PLATFORM. COORDINATE
WITH DOCK DESIGN DRAWINGS AND OWNER.
REMAINING LENGTH OF PIPE WILL BE REMOVED
DURING NEW DOCK CONSTRUCTION PROJECT
X X
X X
X X
X
XX
X X
X X
SD
SD
SD
BROWNSVILLE NAVIGATION CHANNEL
CUT 16" SQUARE CONCRETE PILES
AT EXISTING GRADE/MUDLINE
(GRID T2-T24; 92 PILES)
TC
(VIF)
TB
TA
TD
10', TYP
T5T6T7T8T9 T10T11
T12 T13
T14 T15
T17 T18
T16
T19 T20
T21
T22
T23
T24
A. VILLARREAL
D. R. BROYLES
071" = 20'
00X-04.dwg
BELOW DECK EXISTING DEMO PLAN
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
LEGEND:
PILE TO BE FULLY EXTRACTED AND REMOVED. JETTING PERMITTED, SEE SPECIFICATION
02 41 00 FOR LIMITATIONS. FILLING OF VOIDS NOT REQUIRED.
PILE TO BE CUT AT EXISTING MUDLINE AND REMOVED
REMOVE SHORELINE RIP-RAP AND/OR MISCELLANEOUS DEBRIS
AREA TO BE CLEARED OF ALL OBSTRUCTIONS FOR FUTURE PILE DRIVING OPERATIONS
PHOTOGRAPH OF EXISTING CONDITION, SEE SHEETS 07 THROUGH 14
THE ITEMS IDENTIFIED BELOW SHALL BE REMOVED ACCORDING TO DEMOLITION REQUIREMENTS
SPECIFIED. THESE ITEMS ARE ALSO IDENTIFIED IN DIVE REPORT “BROWNSVILLE NAVIGATION DISTRICT CARGO DOCK #3, DEBRIS REPORT” CONDUCTED BY INDEPTH DIVING SERVICES LLC. ON
OCTOBER 19, 2021 PROVIDED IN SPECIFICATION 02 41 00
BELOW DECK EXISTING/DEMO PLAN
1" = 20'
M
AT
C H
L
IN
E "A
M
AT
C H
LI
N
E "A
1. RIP RAP
2. 3" x 30" STEEL PIPE
3. 2" x 12" FLAT BAR
4. 18" x 18" x 12' TIMBER BOAT BUMPER
5. 12" x 24" FLAT PLATE
6. 18" x 18" x 12' TIMBER BOAT BUMPER
7. 12" x 12" WOOD PLANK
8. 18" x 18" x 12' TIMBER BOAT BUMPER
9. 18" x 18" x 12' TIMBER BOAT BUMPER
10. BROKEN PILE
11. 6" x 48" I-BEAM
12. 2" MOORING LINE
13. 2" MOORING LINE
14. TRIANGULAR 60" PLATE
15. 6" x 6' STEEL PIPE
16. 6" x 2' PVC PIPE
17. 8" x 4' STEEL PIPE
18. 24" FLAT TRIANGULAR PLATE
19. 6" x 6' STEEL PIPE
20. CONCRETE FRAGMENT 60" x 72"
21. 12" x 3' STEEL PILE PAIR
22. 6" x 48" STEEL PIPE
23. 6" x 48" STEEL PIPE
24. 12" METAL SHEET
25. 6" STEEL PIPE
26. 6" STEEL PIPE
27. 6" ANGLE IRON
28. 6" ANGLE IRON
29. SHEET METAL
30. 12" x 3' SHEET PILE PAIR
31. 16" x 40' CONCRETE DRAIN PIPE
RAIL TRESTLE PILE NOTES:
1. PRIOR TO PILE REMOVAL, CONTRACTOR SHALL SURVEY ALL RAIL TRESTLE PILE
LOCATIONS (GRID T1 THRU T24 ALONG WITH DOCK GRID 45) AND SUBMIT DATA FILE
AND ELECTRONIC DRAWING SIGNED AND SEALED BY LICENSED LAND SURVEYOR IN
TEXAS TO THE OWNER FOR RECORD.
2. PILE QUANTITIES AND SPACINGS ARE ESTIMATED ON RAIL TRESTLE.
R .R
. BEAM
CL
R
.R
. BEAM
CL
CHAINLINK FENCE
(TO BE REMOVED AND
SALVAGED BY OTHERS, NIC)
RAIL (TO BE REMOVED
AND SALVAGED BY
OTHERS, NIC)
ED
G
E O
F R
O
AD
REMOVE
CONCRETE DECK
EXISTING
CONCRETE PILES
DITCH
A
CUT PILES AT EXISTING
GRADE/MUDLINE (BELOW RIPRAP)
DH
TOP OF DECK
EL. +13.5' NAVD88
0.0' NAVD88
+0.35' (MHHW)
-1.15' (MLLW)
-28.0' NAVD88 (VARIES)
90'-1 1/2" 75'-6"
Q
REMOVE PERIMETER
CONCRETE WALL AND
FOOTING
REMOVE PERIMETER
CONCRETE WALL AND
FOOTING
37'-0"
REMOVE TIMBER
FENDERS AND TIRES
MUDLINE VARIES
REMOVE EXISTING FILL
DOWN TO EL. +10.0' NAVD88.
STOCKPILE IN PORT
DESIGNATED AREA.
E
-48.5' NAVD88 (APRX)
EXTRACT
50' OAL PILESCUT OFF PILES AT MUDLINE
EL. +10.0' NAVD88
REMOVE SHORELINE
RIP-RAP AND/OR
MISCELLANEOUS DEBRIS
(NOTE: EXISTING IN-FILL STEEL SHEET
PILES APPROXIMATELY 6' LONG, WILL BE
ENCOUNTERED IN SOME AREAS,
REMOVE AND DISPOSE ACCORDINGLY)
R .R
. BEAM
CL
R
.R
. BEAM
CL TOP OF TRESTLE
EL. +13.5' NAVD88
0.0' NAVD88
+0.35' (MHHW)
-1.15' (MLLW)
≈ -19.5' NAVD88
EXTRACT 50' OAL PILES
(SEE PLAN ON SHEET 07)
REMOVE RAIL
AND TRESTLE
MUDLINE VARIES
-48.5' NAVD88 (APRX)
CL
R
.R
. BEAM
TOP OF TRESTLE
EL. +13.5' NAVD88
0.0' NAVD88
+0.35' (MHHW)
-1.15' (MLLW)
CUT PILES AT EXISTING
GRADE/MUDLINE
(SEE PLAN ON SHEET 07)
REMOVE RAIL
AND TRESTLE
MUDLINE VARIES
A. VILLARREAL
D. R. BROYLES
081/8" = 1'-0"
00X-05.dwg
EXISTING DEMO SECTIONS
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
TYPICAL DOCK SECTION
1/8" = 1'-0"
A
TYPICAL SECTION
RAIL TRESTLE (T1)
1/8" = 1'-0"
B
TYPICAL SECTION
RAIL TRESTLE (T2 TO T24)
1/8" = 1'-0"
C
A. VILLARREAL
D. R. BROYLES
09N/A
00X-06.dwg
EXISTING CONDITIONS PHOTOS 01
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
PHOTO 1
PHOTO 6
PHOTO 2
PHOTO 7
PHOTO 3
PHOTO 8
PHOTO 4
PHOTO 9
PHOTO 5
PHOTO 10
A. VILLARREAL
D. R. BROYLES
10N/A
00X-07.dwg
EXISTING CONDITIONS PHOTOS 02
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
PHOTO 11
PHOTO 16
PHOTO 12
PHOTO 17
PHOTO 13
PHOTO 18
PHOTO 14
PHOTO 19
PHOTO 15
PHOTO 20
A. VILLARREAL
D. R. BROYLES
11N/A
00X-08.dwg
EXISTING CONDITIONS PHOTOS 03
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
PHOTO 21
PHOTO 26
PHOTO 22
PHOTO 27
PHOTO 23
PHOTO 28
PHOTO 24
PHOTO 29
PHOTO 25
PHOTO 30
A. VILLARREAL
D. R. BROYLES
12N/A
00X-09.dwg
EXISTING CONDITIONS PHOTOS 04
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
PHOTO 31
PHOTO 36
PHOTO 32
PHOTO 37
PHOTO 33
PHOTO 38
PHOTO 34
PHOTO 39
PHOTO 35
PHOTO 40
A. VILLARREAL
D. R. BROYLES
13N/A
00X-10.dwg
EXISTING CONDITIONS PHOTOS 05
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
PHOTO 41
PHOTO 46
PHOTO 42
PHOTO 47
PHOTO 43
PHOTO 48
PHOTO 44
PHOTO 49
PHOTO 45
PHOTO 50
A. VILLARREAL
D. R. BROYLES
14N/A
00X-11.dwg
EXISTING CONDITIONS PHOTOS 06
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
CARGO DOCK 3
DEMOLITION
K. M. WUNDT
10320226
DESIGNED BY
DRAWN BY
CHECKED BY
HDR Engineering, INC TBPELS Firm Registration No. F-754
PHOTO 51
PHOTO 56
PHOTO 52
PHOTO 57
PHOTO 53
PHOTO 58
PHOTO 54
PHOTO 59
PHOTO 55
PHOTO 60
File details come from the government source that posted it. Updated .