Attachment_3_-_DARPA-BAA-16-09_-_Spec_Template.xlsx

XLSX spreadsheet 13 KB Posted

Attached to
Neural Engineering System Design Federal contract opportunity
Solicitation number
DARPA-BAA-16-09
Issued by
Defense Advanced Research Projects Agency

About this file

Not Listed

View the file

Other files for this federal contract opportunity

Other files attached to Neural Engineering System Design, newest first.
File Type Posted
Attachment_4_-_DARPA-BAA-16-09_-_SOW_Template.docx DOCX document
DARPA-BAA-16-09.pdf PDF
Attachment_1_-_DARPA-BAA-16-09_-_Proposal_Slide_Template.pptx PPTX presentation
Attachment_2_-_DARPA-BAA-16-09_-_Budget_Template.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Required System Specifications

Proposed NESD System Specifications (REQUIRED sheet)
SpecificationUnitMinimum RequirementPhase IPhase IIPhase III
System propertiesEnter subtask number
External dimensionsmm x mm x mmAll estimated values should be highlighted in yellow
Total volumecm^3All calculated values should be highlighted in green
Weightg
Power consumption (worst-case)mW
Temperature rise (worst-case at a local hot spot)degrees Celcius1
Material(s) interacting with tissue
Proposer-defined safety metricsProposer-defined
Proposer-defined safety metricsProposer-defined
Water vapor transmission rateg/m²/day
Manufactured stimulus transducerEnter subtask number
Number of independent stimulus channels100,000
Rate of stimulus (after multiplexing/beamforming)neurons/sec
Spatial resolutionµm25
Worst-case signal isolation between neurons at target locationdB60
Repeatability (%chance stimulus will induce firing)%
Unintended stimulus (%chance non-target neuron fires)%
Worst-case SAR of stimulus into tissue, if appropriateW/kg
Center wavelength for stimulation, if appropriatemeters
FWHM of stimulation, if appropriatemeters
Manufactured recording transducerEnter subtask number
Number of independent record channels1,000,000
Rate of record (after multiplexing/beamforming)channels/sec
Spatial resolutionµm25
Worst-case signal isolation between channelsdB60
False negative (accuracy of detecting single neuron fire)%
False positive (non-target neuron detected)%
Worst-case SAR of recording probe into tissue, if appropriateW/kg
Center wavelength for recording, if appropriatemeters
FWHM of recording, if appropriatemeters
Manufactured full-duplex transducerEnter subtask number
Worst-case SAR of full-duplex into tissue, if appropriateW/kg
Number of independent stimulus channels1,000
Rate of stimulus (after multiplexing/beamforming)neurons/sec1,000
Stimulus spatial resolutionµm25
Worst-case signal isolation between neurons at target location
(includes record-stim, record-record, and stim-stim)dB60
Repeatability (%chance stimulus will induce firing)%
Unintended stimulus (%chance non-target neuron fires)%
Stimulus latency (from output of sensory transform to neuron fire)msec10
Number of independent record channels1,000
Rate of record (after multiplexing/beamforming)channels/sec1,000
Record spatial resolutionµm25
False negative (accuracy of detecting single neuron fire)%
False positive (non-target neuron detected)%
Record latency (from neuron fire to sensory transform detection)msec10
Center wavelength for stimulation, if appropriatemeters
FWHM of stimulation, if appropriatemeters
Center wavelength for recording, if appropriatemeters
FWHM of recording, if appropriatemeters
Neural-transducerEnter subtask number
Energy efficiency of stimulusµWatt equivalent / channel
Energy efficiency of recordµWatt equivalent / channel
Center wavelength for stimulation, if appropriatemeters
Center wavelength for recording, if appropriatemeters
FWHM of recording, if appropriatemeters
Specificity of stimulation
Specificity of recording
Sensory transformsEnter subtask number
Proposer-definedProposer-defined
Proposer-definedProposer-defined
[...][...]
Compression, representation, and implanted computationEnter subtask number
Proposer-definedProposer-defined
Proposer-definedProposer-defined
[...][...]
Computation design (e.g. COTS part number, ASIC at tech node, etc.)
Energy budget for compressionmW/action potential
Link budget for compressed databits/action potential
Energy budget for representation
Link budget for representation
OutcomesEnter subtask number
Sample size
Proposer-defined outcome measureMCID
Proposer-defined outcome measureMCID
[...][...]
Proposer-defined study success criterion
Proposer-defined study success criterion
[...][...]
Proposer-defined patient success criterion
Proposer-defined patient success criterion
[...][...]
Wireless and SecurityEnter subtask number
Proposer-defined security metricProposer-defined
Proposer-defined security metricProposer-defined
[...][...]
Telemetry wavelength(s)
Total bandwidth available for data transmitMbit/sec
Total bandwidth available for data receiveMbit/sec
Standards used for telemetry
Power transmission efficiency in tissue%
Estimated depth of implanted antennamm
Power transmittedmW
External Body-worn SystemEnter subtask number
Weightg
External dimensionsmm x mm x mm
Time between recharge/replace batterieshours
Alignment tolerance