Dahlia Curtains - Special Cleaning Instructions.pdf
PDF 253 KB Posted
- Solicitation number
- 36C24423Q0622
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24423Q0622.docx | DOCX document | |
| P09 - SOW - Laundry _ Linen Services - VAPHS.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Med-Arc Cubicle
SILVER ANTIMICROBIAL FIBER
Dahlia-X
HEADQUARTERS:
NEW YORK
Arc-Com Fabrics, Inc.
33 Ramland South, Orangeburg, NY 10962 Tel (845) 365-1100 (800) 223-5466 Fax (845) 365-1285 www.arc-com.com
NAME Dahlia-X
CONTENT 97% FR Polyester, 3% silver antimicrobial fiber
WIDTH 72 inches
REPEAT Approx. 72” H. x 66” V.
APPLICATION Cubicle, Drapery, Bedcovering
ENVIRONMENTAL Up to 50% of the silver used in silver antimicrobial fiber is recycled.
INFO This fabric can contribute to LEED® Certification.
Dahlia-X is part of the Med-Arc Continua Collection.
Other patterns in this collection include Ebb-X, Fractal-X, Melody-X, Petal-X, and Structure-X.
Copyright ©2014 Arc-Com Fabrics, Inc. All Rights Reserved.
MADE IN USA
ƒ ø ß Í *
*ACT® Registered Certification Marks
Technical Data: This fabric has passed:
1 ) NFPA 701.
2 ) City of Boston (Sample must be submitted for each project).
3 ) Lightfastness: AATCC Method 16 exceeds 60 hours. Class 4.5.
4 ) NY/NJ Port Authority.
5 ) (VOC) - Volatile Organic Emission Test; Tested for Formaldehyde Emissions and Total Volatile Organic Compounds.
Results: Non-detectable.
6 ) This product has been proven effective after 200 commercial launderings and has been tested in accordance with
ASTM E-2149. Laboratory test reports are intended to be used as guidelines, not as a guarantee of performance. Test reports are available upon request or by visiting www.arc-com.com/dahlia_x.
Fabrics containing solely protect the finished product itself from microbial growth.
Special Laundering Instructions Apply:
Please contact your sales representative or visit www.arc-com.com/dahlia_x
SHOWROOMS
Atlanta • Boston • Chicago • Dallas • Houston • Los Angeles • New York City • San Francisco • Washington, DC
INTERNATIONAL
Australia • British Columbia • Calgary • Hong Kong • Mexico • Montréal • Taiwan • Toronto
AREA OFFICES
Austin • Baltimore • Birmingham • Charlotte • Cincinnati • Clearwater • Denver • Detroit • Indianapolis • Kansas City Memphis • Milwaukee • Minneapolis • Nashville • New Orleans • Orlando • Philadelphia • Phoenix • Pittsburgh • Richmond Seattle • South Florida • St. Louis
X-Static® Cubicle Laundering Instructions:
• Load Fabric into washer (Do Not Overload).
| • | Use | the | usual | hospital | protocol | (rinse, | drain, | etc.), | for | washing | cubicles | and | note | maximum | temperature |
| of | 160°F |
• Detergent must be non-ionic (with cloud point above 160°F) with a maximum pH not to exceed 10.
| • | Oxidative | bleaching agents should not be used | as | these | will | damage | X-Static | silver | antimicrobial | fiber. |
| These | include | sodium, | hypochlorite, | hydrogen | peroxide, | and | per(oxy)acetic | acid | (PAA). |
| • | A | thorough | rinse | is | essential | to | remove | traces | of | surfactant, | as | residual | detergent | will | adversely | affect |
| the | X-Static | silver | antimicrobial. |
• Do not overload washer or dryer.
• Fabric softeners should not be used.
| • | Always | ensure | that | the | fabric | is | thoroughly | dried | with | heat. | The | dryer | exhaust | temperature | should | not |
| exceed | 160°F. |
| • | Washers | and | dryers | should | be | inspected | regularly | to | ensure | there | are | no | rough | spots | that | could | damage |
| the | fabric. |
| • | As | is | the | usual | procedure | with | laundering | synthetic | cubicle | curtains, | after | the | dry | cycle | is | complete, |
| curtains | should | be | quickly | removed | to | avoid | over | exposure | to | the | heat | drying | cam. |
• Silver is a natural element and may tarnish. This does not affect the biocidal properties of the material.
| • | Always | process | one | single | cubicle | first | before | processing | bulk | cubicles. | A | thorough | examination | & | ||
| evaluation | of | the | test | cubicle | should | be | reviewed | to | make | sure | that | the | proper | results | are | attained. |
For any questions, please contact our Technical Department:
ACTech@arc-com.com or 1-800-223-5466 x4882
Arc-Com Fabrics, Inc.
33 Ramland South Orangeburg, NY 10962
Tel (845) 365-1100 (800) 223-5466 Fax (845 365-1285 www.arc-com.com
Cleaning Instructions:
Dahlia-X
List of Incompatible Chemicals for Use With X-Static Silver Antimicrobial Fiber
| The | Table | below | contains | a | general | list | of | chemicals | that | are | incompatible | for | use | with | X-Static | filament | or | staple |
| fibers. | While | this | list | is | not | comprehensive, | it | does | reference | the | most | common | chemicals | used | in | processing, | dyeing, | |
| finishing | and | laundering | that | are | incompatible | with | the | X-Static | technology. |
Incompatible Chemicals
Effect on
X-Static Silver Antimicrobial Fiber
Impact on End-Use Requirement
Recommended Substitutes
Sulfur Powder Sulfur degrades X-Static
| • | Potential | issue | with | consis- |
| tency | of | color, | luster |
| • | Potential | issue | with | reduc- |
| tion | in | thermal | and | electrical |
properties
| • | Non-sulfur | powder-contain- |
| ing | chemicals |
| • | Non-sulfur-containing | atmo- | ||
| sphere | (that | is, | away | from |
| high | vehicle | exhaust | areas) |
| Ammonium | Sulfide | ||
| Sulfur | containing | compounds | degrade |
X-Static
| • | Potential | issue | with | consis- |
| tency | of | color, | luster |
| • | Potential | issue | with | reduc- |
| tion | in | thermal | and | electrical |
properties
| • | Non-ammonium | sulfide- |
| containing | chemicals |
Sodium Hypochlorite
(Household Bleach)
Sodium hypochlorite degrades X-Static
| • | Potential | issue | with | consis- |
| tency | of | color, | luster |
| • | Potential | issue | with | reduc- |
| tion | in | thermal | and | electrical |
properties
| • | Non | hypochlorite-containing |
| cleaning | agents |
Chlorine Gas Chlorine degrades X-Static
| • | Potential | issue | with | consis- |
| tency | of | color, | luster |
| • | Potential | issue | with | reduc- |
| tion | in | thermal | and | electrical |
properties
| • | Non-hypochlorite-containing |
| cleaning | agents |
| All | Strong | Acids | ||
| Strong | acids | degrade, | dissolve | and |
| oxidize | X-Static |
| • | Potential | issue | with | consis- |
| tency | of | color, | luster |
| • | Potential | issue | with | reduc- |
| tion | in | thermal | and | electrical |
properties
| • | Alternate | process | that |
| does | not | expose | X-Static to |
| strong | acids |
Strong Oxidizing Agents
| Strong | oxidizing | agents, | degrade, |
| dissolve | and | oxidize | X-Static |
| • | Potential | issue | with | consis- |
| tency | of | color, | luster |
| • | Potential | issue | with | reduc- |
| tion | in | thermal | and | electrical |
properties
| • | Alternate | process | that |
| does | not | expose | X-Static to |
| strong oxidizing | agents |
| Sodium | Silicate | ||
| Sodium | Silicate | reacts | with |
X-Static
| • | Visual | color | change | |
| • | Deposits | of | orange | yellow |
precipitate of silver silicate on substrate
| • | Magnesium | salts | of | ethyl- |
| enediamine | tatra | acetic | acid | |
| (EDTA) | and | tetrasodium | ||
| pyrophosphate | (TSPP) |
| Sodium | Hydrosulfite |
| (Sodium | Dithionite) |
| Degrades | X-Static and | effects | overall |
| hue | of | fabric |
| • | Potential | issue | with | consis- |
| tency | of | color, | luster |
| • | Potential | “tea | stains” | on | fin- |
| ished | fabric |
| • | Potential | uniform | change | in |
| hue | (towards | brown) |
| • | Potential | issue | with | reduc- |
| tion | in | thermal | and | electrical |
properties
| • | Non | hydrosulfite | reducing |
| agents | such | as | isopropyl |
alcohol
X-Static Cleaning Guide
General Cleaning Recommendation:
• Load Fabric into washer (Do Not Overload).
• Use the usual hospital protocol (rinse, drain, etc.), for washing cubicles and note maximum temperature of
200°F
• Detergent with a maximum pH not to exceed 12.
• Oxidative bleaching agents should not be used as these will damage X-Static silver antimicrobial fiber.
These include sodium, hypochlorite, hydrogen peroxide, and per(oxy)acetic acid (PAA).
• A thorough rinse is essential to remove traces of surfactant, as residual detergent will adversely affect the
X-Static silver antimicrobial.
• Do not overload washer or dryer.
• Fabric softeners should not be used.
• Always ensure that the fabric is thoroughly dried with heat. The dryer exhaust temperature should not exceed 200°F.
• Washers and dryers should be inspected regularly to ensure there are no rough spots that could damage the fabric.
• As is the usual procedure with laundering synthetic cubicle curtains, after the dry cycle is complete, curtains should be quickly removed to avoid over exposure to the heated drying cam.
• Silver is a natural element and may tarnish. This does not affect the biocidal properties of the material.
• Always process one single cubicle first before processing bulk cubicles. A thorough examination & evaluation of the test cubicle should be reviewed to make sure that the proper results are attained.
| Dahlia |
| Dahlia_Cleaning |
| X-STATIC_Cleaning-Dahlia Curtain-Fabric Composition |
File details come from the government source that posted it. Updated .