2. Minimum and Specific Requirements.pdf

PDF 199 KB Posted

Attached to
Recruiting Station - Armed Forces Career Center -Hollywood, FL
Solicitation number
DACA175240007000
Issued by

About this file

This document appears to be the Minimum and Specific Requirements for a federal contract opportunity related to providing commercial storefront/retail space for an Armed Forces Career Center in Hollywood, FL.

The key details are: the Government requires between 5,444 to 6,805 gross rentable square feet of space containing specific features such as private offices, open workspaces, testing/conference rooms, storage rooms, common areas (restrooms, janitorial closet, network/security closet), and assigned parking for approximately 20 Government vehicles. The lease is for a 5-year term with Government termination rights, and a full-service lease (utilities and janitorial services included) is preferred. The Government will select a location based on evaluation factors and lowest overall cost. A Government appraisal will be conducted to determine fair market rental value. Proposals are due by April 26, 2024, and the selection is expected approximately 30 days after that.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Minimum and Specific Requirements

- 1 -

Armed Forces Career Center

Minimum Usable Square Footage: 5,444 SF

Maximum Usable Square Footage: 6,805 SF

Minimum Requirements for All Offices:

1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.

2. 24-hour lighted or secured parking within the lessor’s premises for TWENTY (20) Government vehicles.

3. Adequate parking for 23 Service member privately owned vehicles during working hours, as well as for office visitors.

4. 24-hour access to the leased spaces.

5. High-speed data service connection (Fiber is preferred) from the street to the building demarcation point.

Army Specific Requirements 2,281 SF Min – 2,851 SF Max:

1. Private Offices: One (1) private office of 100 SF within each individual Armed Forces

Center; see specific requirements detailed within the construction specifications.

2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 9 workstations.

3. Testing/Conference Room: One (1) testing room of 100 SF with a window or a glass door facing the open area for test monitoring.

4. Storage Room: One (1) storage room of 100 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board. An additional 30 SF shall be allocated if separate

CCTV/Security closet is required.

- 2 -

Navy Specific Requirements 1,192 SF Min – 1,490 SF Max:

1. Private Offices: One (1) private office of 100 SF within each individual Armed Forces

Center; see specific requirements detailed within the construction specifications.

2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 4 workstations.

3. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.

4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board. An additional 30 SF shall be allocated if separate

USMC Specific Requirements 1,208 SF Min – 1,510 SF Max:

1. Private Offices: One (1) private office of 100 SF within each individual Armed Forces

Center; see specific requirements detailed within the construction specifications.

2. Open Space for cubicles or work stations: Space lay out to include an open area within the suite for 2 work stations.

3. Testing/Conference Room: One (1) testing room of 80 SF with a glass door facing the open area for test monitoring. This testing room will NOT have a window installed.

4. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, communications board. An additional 40 SF shall be allocated if separate

Air Force Specific Requirements 618 SF min – 772 SF Max:

1. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 2 workstations.

2. Testing/Conference Room: One (1) testing room of 70 SF with a window or a glass door facing the open area for test monitoring.

3. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage,

- 3 -communications board. An additional 40 SF shall be allocated if separate

Common Area Requirements:

1. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 30 SF for CCTV system and entry control system housing. This closet should be located in the common area of the multiple Service station.

2. Restrooms: A minimum of TWO (2) 100 SF, located in the common area, each restroom meeting ADA specifications built to accommodate at least two occupants at one time.

3. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications. The janitorial closet must be located in the common area.