This document outlines the minimum and specific requirements for an Army Recruiting Station Career Center in Largo, Florida. The space must be between 1,547-2,188 gross square feet and include two private offices of 125 square feet each, an open area with space for six workstations, a 100 square foot testing/conference room with a window or glass door facing the open area, a 100 square foot storage room preferably in the rear of the suite, and a 12 square foot network/CCTV closet located in a private office or common area. Common areas must include a 100 square foot unisex restroom, a 64 square foot female restroom meeting ADA standards, and a 20 square foot janitorial closet. Additional requirements specify 24-hour secured parking for five government vehicles and adequate parking for privately owned vehicles during working hours, 24-hour access to leased spaces, and high-speed data service connection from the street to the building. The related federal contract opportunity is solicitation number DACA175240003200 for the Army Career Center in Largo, Florida issued by the Department of the Army Corps of Engineers Engineering District Jacksonville.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

- 1 -

Minimum and Specific Requirements

Armed Forces Career Center

Minimum Gross Square Footage: 1,547 SF

Maximum Gross Square Footage: 2,188 SF

Minimum Requirements for All Locations:

1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.

2. 24-hour lighted or secured parking within the lessor’s premises for 5 Government vehicles.

3. Adequate parking for service member privately owned vehicles during working hours.

4. 24-hour access to the leased spaces.

5. High-speed data service connection from the street to the building demarcation point.

Army Recruiting Station Specific Requirements:

1. Private Offices: Two (2) private offices of 125 SF within each individual Armed Forces Center; see specific requirements detailed within the construction specifications.

2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 6 workstations.

3. Testing/Conference Room: One (1) testing room of 100 SF with a window or a glass door facing the open area for test monitoring.

4. Storage Room: One (1) storage room of 100 SF for supplies/equipment storage, preferably in the rear of the suite.

5. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 12 SF for CCTV system and entry control system housing. This closet should be located in the private office or built into the common area if a multiple Service station.

Minimum and Specific Requirements

- 2 -

Common Area:

1. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 12 SF for CCTV system and entry control system housing. This closet should be located in the private office if a single Service station or built into the common area if a multiple Service station.

2. Restrooms: A minimum of (2) unisex 100 SF restroom and One (1) female 64 SF restroom meeting ADA specifications. Construction specifications will indicate if more than one restroom is required

3. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications.