Distribution Statement A. Approved for public release; distribution is unlimited.

Project Manager Maneuver Ammunition Systems

Product Director Special Ammunition and Weapon Systems

GENERAL SPECIFICATION FOR

ROCKET PROPELLED & SPIN STABILIZED

GRENADE AMMUNITION

24 August 2020

1. SCOPE

1.1 Scope. This general specification describes the performance requirements and verification procedures for the Rocket Propelled and Spin Stabilized Grenade Ammunition.

2. APPLICABLE DOCUMENTS

2.1 General. In addition to documents listed in this section, there are documents specified in section 5 of this specification.

2.2 Government documents. Not Applicable.

2.3 Non-Government publications.

a) United Nations Recommendations on the Transport of Dangerous Goods Model

Regulations, 21st Edition, 2019 (or latest revision).

b) International Civil Aviation Organization (ICAO) Technical Instructions for the Safe

Transport of Dangerous Goods by Air, 2019-2020 Edition (or latest revision).

c) International Maritime Organization (IMO) International Maritime Dangerous Goods

Code (IMDG), 2018 Edition, Amendment 39-18 (or latest revision).

2.4 Acquisition requirements. Acquisition documents must specify the following:

a. Title and date of this specification.

b. Requirements for certificates of conformance for each lot or shipment of product.

c. Requirements for age of ammunition.

d. Requirements and provisions for submission of data as required.

e. Requirements for acceptance criteria if different than those stated in specification.

f. Requirements for reduction or elimination of verification procedures.

g. Requirements and provisions for contractor and Government verification.

h. Requirements and provisions for packaging of ammunition.

i. Requirements and provisions for transportation of ammunition.

General Specification for PdD SAWS Rocket Propelled & Spin Stabilized Grenades - 24 August 2020

2.5 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Requirements specified in the contract or delivery order precede the text of this document. Nothing in this document or the contract, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.

3. REQUIREMENTS

3.1 Technical requirements. Ammunition shall meet the requirements and verifications of this specification for the rocket propelled and spin stabilized grenade ammunition listed in ANNEX A. Any grenade ammunition that can be categorized as rocket propelled or spin stabilized but is not specifically identified in ANNEX A must still adhere to the testing parameters of this specification.

All rocket propelled and spin stabilized grenade ammunition shall be accompanied with technical data

(see APPENDIX) that meets or exceeds the requirements of this specification.

3.1.1 Compliance to technical requirements and storage history records. A Technical Data

Package (TDP) as well as lot history reports shall be provided to ensure ammunition is in compliance with this specification. Additionally, documented storage history of the ammunition shall be provided.

3.2 Conformance Testing and Inspection. A sample of the grenade ammunition from each lot shall be subjected to conformance testing and inspection in accordance with TABLE I.

3.2.1 Stock ammunition. All grenade ammunition must be less than 5 years old and meet the verification procedures in TABLE I of this specification. Any lot that has not been adequately tested to comply with all requirements of Table I shall be subjected to conformance testing and inspection in accordance with this specification.

3.3. Serviceability. Grenade ammunition shall be serviceable and issuable, in good condition and without visible signs of degradation. All parts and assemblies shall be free of burrs, folds, chips, sharp edges, cracks, surface defects, dirt, grease, rust, corrosion and other foreign material that may adversely affect fit or function. Coatings and protective finishes shall be uniform and shall provide complete coverage of designated surfaces. The painting and marking shall be restored by the assembling facility on any components that have been marred or obliterated.

3.3.1 Identification of defects. Visual defects shall be identified within the TDP and include a defined method for acceptance/rejection of the grenade ammunition. Visual inspections listed in

ANNEX C shall be the minimum requirement.

3.4 Weapon interface and interoperability. The grenade ammunition shall be functionally compatible with the weapons listed in ANNEX A or as otherwise specified in the contract or delivery order.

3.5 Operating requirements. The grenade ammunition shall provide their functional, operational, and performance capabilities when fired from the weapons listed in ANNEX A, regardless of weather related conditions (example: rain, snow, mud, wind, fog). Should the contractor decide to test in inclement weather, all necessary safety precautions shall be put in place.

3.5.1 Operating temperatures. The grenade ammunition shall demonstrate safety and reliability throughout exposure to ambient and extreme temperatures (example: +50°C to -40°C).

3.5.2 Muzzle velocity. The average velocity of the grenade ammunition obtained at ambient temperature shall meet the requirements listed in ANNEX B.

3.5.3 Chamber pressure. The individual max pressure and average pressure of the grenade ammunition obtained at ambient shall meet the requirements listed in ANNEX B.

3.5.4 Maximum effective range. The maximum effective range of the grenade ammunition when tested at ambient shall meet or exceed the requirements listed in ANNEX B.

3.5.5 Dispersion. The grenade ammunition shall demonstrate dispersion characteristics at ambient as specified in the TDP.

3.5.6 Function and casualty. The grenade ammunition shall function without casualty or cause damage to the weapon, and shall exhibit a ballistic performance free of misfires, duds, premature bursts, short rounds, and metal parts separation. The ammunition shall cause no hazard or unsafe condition to the user during storage, transportation or use.

3.5.7 Fragmentation. The grenade ammunition shall provide the lethal fragmentation at the desired radius for each item as specified in ANNEX B. (High Explosive/Fragmentation (HE/FRAG)

Grenades only).

3.5.8 Penetration. The grenade ammunition shall meet the armor penetration characteristics as specified in ANNEX B. (High Explosive Anti-Tank (HEAT) Grenades only).

3.6 Fuze identification and description. Within each TDP the fuze shall be identified with a drawing/figure of the internal fuze design with components categorized to include the type and weight of energetic material(s) and a functional description of the fuze that includes, at a minimum, a detailed description of the fuze arming sequence, operating temperatures, in-process tests (example: jolt/jumble, sensitivity, safe arming/non-arming etc.), and safe separation distances. Test records shall be available to the US Government for verification.

3.7 Environmental Requirements.

3.7.1 Sequential rough handling. Grenade ammunition shall be capable of withstanding the rigors of the sequential rough handling and transportation throughout extreme temperature ranges and meet all performance and safety requirements.

3.7.2 Shelf life. The grenade ammunition shall meet all requirements of this specification within its operating temperature range at a minimum of ten (10) years.

4. VERIFICATION

4.1 Technical verification. The grenade ammunition shall be subjected to verification of all requirements cited in section 3 in this specification, in accordance with the TABLE I. Noncompliance to any requirements shall be cause to withhold acceptance of the lot or batch in which the noncompliance was found.

TABLE I – Requirements/Verification Cross-Reference Matrix

4.1.1 Lot formation. The grenade ammunition shall be assembled into identifiable lots, sublots, or batches, or in such other manner as may be prescribed. Each lot or batch shall, as far as practicable, consist of units of product of a single type, grade, class, size, and composition, manufactured under essentially the same conditions, and at essentially the same time. Lot quantities shall be determined by the total quantity for shipment and include the additional rounds from the same lot to be consumed during lot acceptance testing along with contingency rounds for potential retesting. The lots or batches shall be identified by the contractor and shall be kept intact in adequate and suitable storage space. All grenades in a given lot must be manufactured prior to lot acceptance testing.

4.1.2 Conformance verification. The grenade ammunition shall be subjected to verification in accordance with TABLE I of this specification.

4.1.3 Conformance acceptance. Acceptance of grenade ammunition shall be based on compliance with requirements in TABLE I of this specification. Failure to meet requirements of TABLE

I shall be cause to withhold acceptance of the lot or batch for which verification was performed. A

Request for Variance (RFV) may be submitted for special consideration of a lot that does not comply with all requirements of the TDP. The US Government may approve or disapprove RFVs on a case by case basis.

Section 3

Requirements Requirement

Section 4

Verification

Procedures

Sample Size

3.1 Technical requirements 4.1 -

3.3 Serviceability 4.3 Note 1

3.3.1 Identification of defects 4.3 ANNEX C

3.4 Weapon interface and interoperability

4.4 ANNEX A

3.5.1 Operating temperatures 4.5.1 ANNEX A

3.5.2 Muzzle velocity 4.5.2 ANNEX B

3.5.3 Chamber Pressure 4.5.3 ANNEX B

3.5.4 Maximum effective range 4.5.4 ANNEX B

3.5.5 Dispersion 4.5.5 ANNEX B

3.5.6 Function and casualty 4.5.6 ANNEX A

3.5.7 Fragmentation 4.5.7 ANNEX B

3.5.8 Penetration 4.5.7 ANNEX B

5.1 Packaging - ANNEX C

5.3 Packing - ANNEX C

5.5 Marking - ANNEX C

Note 1) To be performed using a defined sampling procedure for inspection determined by the ammunition lot sizes.

4.1.4 Retest criteria. A ballistic retest is authorized upon initial failure of ammunition to meet test requirements as long as the failure is not considered critical. Retest procedures must be clearly defined in the TDP and results must be combined with data from the first test unless a failure analysis confirms that the failure was caused by something other than the ammunition (example: weapon failure or faulty test set up).

4.2 Verification of evidence of compliance. Evidence shall include, but is not limited to, the following;

a. Identification of technical requirements to which the grenades is/was produced.

b. Producer, date of manufacture and original acceptance documentation.

c. Initial acceptance reports, including type, lot or batch identification, quantity and method of acceptance (example: sample size, verification method, acceptance criteria, results…).

d. Surveillance reports, including lot or batch identification, quantity and method of surveillance

(example: sample size, verification method, criteria for action to be taken on lot or batch, results).

e. Storage history, including duration and storage condition (example: controlled, uncontrolled).

4.3 Serviceability and identification of defects. A random sample shall be selected from each lot of grenades using a defined sampling procedure for inspection. Grenades and packaging shall be of good condition without visible signs of degradation. The grenades shall be visually inspected for signs of degradation and the identification of defects according to the producer’s technical data. Re-inspection of a lot that fails for non-ballistic reasons is authorized as long as the criteria for re-inspection is clearly outlined in the technical data.

4.4 Weapon interface and interoperability. A random sample shall be selected from each lot of grenades to be delivered and inserted into a weapon chamber or chamber gage that conforms to the identified weapon system to check for profile and alignment. Inability to interface properly with weapon system shall be considered a failure to show compliance and constitute a single reliability failure.

4.5 Operating verification. The same cartridge of ammunition can be used for multiple tests provided the test equipment is capable of capturing all necessary test data. For example; Muzzle

Velocity, Maximum Effective Range and Function & Causality testing can be done at the same time using the same cartridges. Called warmers and spotters are allowed and encouraged. "Called" means that before the cartridge is loaded into the weapon, the US Government representative must be informed that the next cartridge to be fired is a warmer or spotter. Should a cartridge not be "Called" it shall be counted toward whichever test is being conducted, potentially resulting in a LAT failure. Safety failures apply to all cartridges fired during LAT, regardless of which test is being performed. The following safety failures shall result in the immediate rejection of the lot; there shall be no retest:

a. Detonation, Deflagration, or function within the weapon (all cartridge types).

b. Detonation of an HE or HEAT cartridge before impact with the ground or target.

c. An early function of a Practice (Live) cartridge before impact with the ground or target which exposes the operator to smoke, fragmentation or fire.

d. An early function of Smoke, Airburst or Illumination cartridge which exposes the operator to smoke, fragmentation or fire.

e. Metal parts separation.

f. A cartridge that either causes injury to user, damages the weapon or renders it inoperable

(without the use of special tools).

4.5.1 Operating temperatures. Grenade ammunition shall operate reliably and safely when conditioned and fired throughout reasonable extreme operating temperature range as provided by the manufacturer. Temperature testing shall be conducted on a skip-lot basis (see APPENDIX) during LAT.

A single safety failure will result in lot rejection and there shall be no retest. Functional testing parameters must be defined in the technical data and meet manufacturer requirements. The entire cartridge, including all components necessary to fire and function (example: fuze, warhead, propellant, etc.) shall be temperature conditioned based on the maximum cartridge body diameter. Additionally the cartridges shall be fired within the following times after being removed from the conditioning chamber or thermally insulated bag.

a. Ammunition less than 85mm in diameter shall be conditioned for not less than six (6) hours and fired within five (5) minutes of removal from conditioning box or thermally insulated bag.

b. Ammunition between 85mm and 120mm in diameter shall be conditioned for not less than nine (9) hours and fired within six (6) minutes of removal from conditioning box or thermally insulated bag.

c. Ammunition greater than 120mm in diameter shall be conditioned for not less than twelve

(12) hours and fired within eight (8) minutes of removal from conditioning box or thermally insulated bag.

4.5.2 Muzzle velocity. Velocity tests shall be conducted in accordance with the manufacturers test procedures to verify that a sample representative of the lot meets the velocity requirements specified in ANNEX B (10 cartridges minimum). If the lot fails to meet the Velocity requirements a retest of the same sample size (10 cartridges minimum) is permitted. The cumulative average of all cartridges tested

(20 cartridges minimum) shall be used to determine if the lot passes.

4.5.3 Chamber pressure. Pressure tests shall be conducted in accordance with the manufacturers test procedures to verify samples from the lot do not exceed the average or individual pressure requirements listed in ANNEX B (10 cartridges minimum). Although pressure testing during LAT is preferred, in process testing will be accepted. If the lot fails to meet the Pressure requirements a retest of the same sample size (10 cartridges minimum) is permitted. The cumulative average of all cartridges tested (20 cartridges minimum) shall be used to determine if the lot passes. Any single round that exceeds the maximum individual pressure requirement will result in lot rejection, there shall be no retest.

4.5.4 Maximum Effective Range. Maximum effective range shall be verified during lot acceptance testing to ensure compliance with ANNEX B.

4.5.5 Dispersion. Dispersion tests shall be conducted to verify that each lot of ammunition meets the specified requirements in the TDP (10 cartridges minimum). If the lot fails to meet the Dispersion requirements or a round misses the target, a retest of the same sample size (10 cartridges minimum) is permitted. The cumulative average of all cartridges tested (20 cartridges minimum or 19 cartridges if one misses the target), shall be used to determine if the lot passes. If two (2) or more cartridges miss the target (cumulative) the lot fails.

4.5.6 Function and casualty. A random sample shall be selected from the ammunition lot in accordance with ANNEX A to be delivered and functioned from the identified weapon system to check for function, casualty and metal parts security. The ammunition shall function across the entire operating temperature range without casualty or damage to the weapon, and shall exhibit a ballistic performance free of misfires, duds, premature bursts, short rounds and metal parts separation. A short round is defined as a cartridge that has half of the muzzle velocity of the others within its group and/or impacts the ground at a range 50% or less of the range average or its respective temperature/charge/group; excluding the cartridge(s) in question. If a cartridge has a Multi-option fuze, all options shall be tested during Lot

Acceptance Testing to properly demonstrate the fullest extent of the munitions capability unless specified otherwise in Annex A or by the US Government during solicitation. The different fuze options test quantity will be distributed amongst the total Function and Casualty requirement. The ammunition shall cause no hazard or unsafe condition to the user during storage, transportation or use. Critical safety failures are listed in section 4.5 of this specification.

4.5.7 Performance. Proper functioning for each grenade ammunition type is defined below.

Any round which does not function properly according to the below definitions, the requirements in

ANNEX A and B, and the requirements in the TDP is considered a function failure:

a. Fragmentation: The ammunition, with a point detonate fuze, shall produce a high-order detonation of the warhead upon initial impact with the target (terrain or man-made structure) as specified in the TDP. If fuze contains a delay the ammunition shall detonate after impact with target at a specific time or distance as specified in the TDP.

b. Bounding: The ammunition shall bound/jump after initial impacting with the ground and produce a high-order detonation of the warhead above ground between a low/high height as specified by the manufacturer in the TDP.

c. Airburst: The ammunition shall produce a high-order detonation of the warhead above ground between a min/max distance as specified by the manufacturer in the TDP.

d. Proximity: The ammunition shall produce a high-order detonation of the warhead within a min/max distance of target as specified by the manufacturer in the TDP.

e. HEAT: The ammunition shall produce a high-order detonation resulting in jet capable of penetrating armor at a depth as specified in the TDP.

f. Smoke: The ammunition shall produce a volume of smoke upon impact with the target as specified by the manufacturer in the TDP.

g. Illumination: The ammunition shall produce parachute suspended light at specific intensity, duration, wavelength, and height as specified by the manufacturer in the TDP.

h. Penetration: The ammunition shall meet the armor penetration characteristics as specified in the TDP.

i. Practice (Inert): The ammunition shall not contain any explosives or energetics other than propellant.

j. Practice (Live): The ammunition may contain energetics, other than propellant, to signal location of impact.

5. PACKAGING

5.1 Preservation, packaging, packing, unitization, and marking shall provide protection for multiple handling, redistribution, and shipment by any transportation mode and meet or exceed the following requirements.

5.1.1 Packaging containers for hazardous materials, ammunition and explosives shall meet or exceed the requirements found in part 6 of the "United Nations Recommendations on the Transport of

Dangerous Goods Model Regulations" and in a manner acceptable to the competent authority of the nation of origin and in accordance with the regulations of all applicable carriers.

5.1.2 Cleanliness - Items and packaging shall be free of dirt and other contaminants which would contribute to the deterioration of the item or which would require cleaning by the customer prior to use.

Coatings and preservatives applied to the item for protection are not considered contaminants.

5.1.3 Preservation - Items susceptible to corrosion or deterioration shall be provided protection against external environmental effects.

5.1.4 Cushioning - Items requiring protection from physical and mechanical damage (example:

fragile, sensitive, critical material) or which could cause physical damage to other items, shall be protected by wrapping, cushioning, pack compartmentalization, or other means to mitigate shock and vibration and prevent damage during handling and shipment.

5.1.5 Wood Packing Material- All natural wood packing material shall be constructed from heat treated lumber and certified by an accredited recognized agency in accordance with International

Standards for Phytosanitary Measures (ISPM-15) regardless of origin or destination. All natural wood packing materials must include certification markings that are readily visible to inspectors and on at least two sides of every container when palletized.

5.1.6 Firing Tables – A copy of the manufacturers firing tables for ammunition shall be included in the TDP if available.

5.2. Unit Package

5.2.1 Unit package shall be so designed and constructed that it will contain the contents with no damage to the item(s), and with minimal damage to the unit pack during shipment and storage in the shipping container, and will allow subsequent handling. The outermost component of the unit package shall be a container such as a sealed bag, carton, or box.

5.3. Packing

5.3.1 Unit packages must be packed in shipping containers. All shipping containers shall be the most cost effective and shall be of the minimum cube to contain and protect the items.

5.3.2 Shipping Containers - the shipping container (including any necessary blocking, bracing, cushioning, or waterproofing) shall comply with the regulations of the carrier used and shall provide safe delivery to the destination at the lowest tariff cost. The shipping container shall be capable of multiple handling, stacking at least ten feet high, and storage under favorable conditions and meet the requirements of the “United Nations Recommendations on the Transport of Dangerous Goods”.

5.4. Unitization

5.4.1 Shipments of identical items going to the same destination shall be palletized if they have a total cubic displacement of 20 cubic feet or more unless skids or other forklift handling features are included on the containers. Pallet loads must be stable, and to the greatest extent possible, provide a level top for ease of stacking. The weight capacity of the pallet must be adequate for the load. A pallet load shall not exceed 4,000 pounds and should not exceed 52 inches in length or width, or 54 inches in height. The load shall be contained in a manner that will permit safe handling during shipment and storage.

5.4.2 Banding - metal banding shall be used to secure load. Straps shall be applied to each column or layer of boxes. Tie down straps shall be applied to each column of boxes at 90 degrees to the load straps. Edge protectors shall be used when securing fiberboard boxes.

5.5. Marking

5.5.1 Packaging marking shall be visible, clear, and remain legible during normal life cycle handling.

5.5.2 All unit packages, intermediate packs, exterior shipping containers, and, as applicable, unitized loads shall be marked with item description, quantity, lot number, or serial number. The outer shipping container and unitized load shall indicate load weight, UN dangerous goods proper shipping name, UN number and UN POP marking.

5.5.3 Each package shipping container shall show the United Nations packaging symbol and applicable codes in accordance with the construction requirements and testing of packaging as expressed in part 6 of the " United Nations Recommendations on the Transport of Dangerous Goods Model

Regulations".

5.6. Additional Requirements for Hazardous Materials

5.6.1 The shipment shall be prepared in accordance with the "United Nations Recommendations on the Transport of Dangerous Goods Model Regulations" and other applicable regulations effective at the time of shipment in a manner acceptable to the competent authority of the nation of origin and in accordance with the regulations of all applicable carriers.

5.6.2 Packaging and marking for hazardous material shall comply with the requirements for the mode of transport and the applicable performance packaging contained in the following documents:

a. International air transport: International Civil Aviation Organization (ICAO)

Technical Instructions for the Safe Transport of Dangerous Goods by Air.

b. International vessel transport: International Maritime Organization (IMO)

International Maritime Dangerous Goods Code (IMDG).

Frank Altamura Product Director Special Ammunition and Weapon Systems

Picatinny Arsenal, NJ

Annex A: Weapon Interface

Annex B: Operating Requirements

Annex C: Visual Inspection Requirements

APPENDIX – Definitions

General Specification for PdD SAWS Rocket Propelled & Spin Stabilized Grenades – 24 August 2020

ANNEX A - Weapon Interface

Spin Stabilized Grenades

Item1,8,9

Weapon

Interface

(or similar)

Function and Casualty/Safety

Order size greater than 249 cartridges

Sample Size2-Accept-Reject & Retest (cumulative)

Function and Casualty/Safety

Order size 100-249 cartridges3

Sample Size2-Accept-Reject & Retest

(cumulative)

Ambient Hot Cold Ambient Only

40mm HE Frag.6,7

40mm HE Frag. Bounding4,7

40mm HE Frag. Airburst5

40mm Smoke7

40mm Illumination

40mm Practice

GP 25/30

Grenade

Launcher

26-0-1

Retest 46-1-2

(Cumulative)

26-1-2

Retest 46-2-3

26-1-2

Retest 46-2-3

26-0-1

Retest 46-1-2

(Cumulative)

Out of Mode

Function

(Bounding &

Airburst)

26-3-4

Retest 46-5-6

(Cumulative)

Out of Mode

Function

(Bounding &

Airburst)

26-3-4

Retest 46-5-6

(Cumulative)

Out of Mode

Function

(Bounding &

Airburst)

26-3-4

Retest 46-5-6

(Cumulative)

Out of Mode Function

(Bounding & Airburst)

26-3-4

Retest 46-5-6

ANNEX A - Weapon Interface (continued)

Note 1: Any spin stabilized grenade ammunition not listed in this table are still required to meet sample size-accept-reject criteria listed in this table.

Note 2: These samples sizes shall be used to show performance and function and casualty at ambient temperature. 26 rounds shall be tested for function and safety at the operating temperature extremes. A minimum of 10 data points is required to evaluate all other test parameters.

Note 3: For orders less than 100 cartridges function and casualty tests are not required. The Government reserves the right to increase these requirements in their proposals.

Note 4: Bounding cartridges shall jump/bound after first impact and detonate at the intended height. A cartridge that detonates outside of the intended height, but within the lethal radius of the cartridge from initial impact shall be counted as an out of mode function. A cartridge that detonates outside of the lethal radius from initial point of impact shall be counted as a function failure.

Note 5: Airburst cartridges shall detonate above ground at the intended distance. A cartridge that detonates outside of the intended distance, but within the lethal radius of the cartridge from initial impact shall be counted as an out of mode function. A cartridge that detonates outside of the lethal radius from initial point of impact shall be counted as a function failure.

Note 6: For these cartridge types only, if they contain a multi-option fuze where the only options are Point Detonate and Delay, they shall be set to Point Detonate during LAT.

Note 7: If the fuze has an adjustable time delay setting it must be set as per approved TDP during Function & Casualty testing.

Note 8: A function failure shall be defined as:

a) A cartridge that will not load into the weapon.

b) A misfire.

c) A short round.

d) Smoke cartridges only: A cartridge that does not produce specified volume of smoke or has early function that does not expose user to smoke, blast, fire or fragmentation.

e) Illumination cartridges only: A cartridge that does not produce light for specified intensity, wavelength, duration and height or has early function that does not expose user to fire, blast, or fragmentation.

f) HE cartridges only: A cartridge that does not completely detonate upon initial impact (excluding bounding type grenades) with their target when equipped with a point detonate fuze. Self-destruct detonation or fuze function only shall be scored as a function failure, if shot as part of a function test. If fuze is set to delay the ammunition shall detonate after impact with target at a specific time or distance as specified in the TDP.

g) Practice (Live) cartridges only: A cartridge that has an early function, or a failure to function before impact with the ground or target that does not expose user to smoke, blast, fire or fragmentation.

h) A cartridge that does not perform its primary function such as penetration, airburst, proximity, etc.

Note 9: Critical safety failures are listed in section 4.5 of this specification.

ANNEX A - Weapon Interface (continued)

Rocket Propelled Grenades

Item1,4,5,6,7

Weapon

Interface

(or similar)

Function and Casualty/Safety

Order size greater than 249 cartridges

Sample Size2-Accept-Reject & Retest (cumulative)

Function and Casualty/Safety

Order size 100-249 cartridges3

Sample Size2-Accept-Reject &

Retest (cumulative)

Ambient Hot Cold Ambient only

40mm HE/Frag Grenade (OG-7V)

40/70.5mm HEAT (PG-7VM)

40/93mm HEAT (PG-7VL)

40mm Practice

RPG-7

Grenade

Launcher

32-0-1

Retest 60-1-2

(Cumulative)

32-1-2

Retest 60-2-3

(Cumulative)

32-1-2

Retest 60-2-3

(Cumulative)

32-0-1

Retest 60-1-2

(Cumulative)

73mm HE (OG-9V)

73mm HEAT (PG-9V)

73mm Practice

SPG-9

Recoilless Gun

15-0-1

Retest 29-1-2

(Cumulative)

15-1-2

Retest 29-2-3

(Cumulative)

15-1-2

Retest 29-2-3

(Cumulative)

15-0-1

Retest 29-1-2

(Cumulative)

Note 1: Any rocket propelled grenade ammunition not listed in this table are still required to meet sample size-accept-reject criteria listed in this table for which type of weapon system it most closely resembles.

Note 2: These samples sizes shall be used to show performance and function and casualty at ambient temperature. The rounds shall be tested for function and safety at the operating temperature extremes (32 rounds for RPG-7 ammunition and 15 rounds for SPG-9 ammunition). A minimum of 10 data points is required to evaluate all other test parameters.

Note 3: For orders less than 100 cartridges function and casualty tests are not required. The Government reserves the right to increase these requirements in their proposals.

Note 4: If the fuze has an adjustable time delay setting it must be set as per approved TDP during Function & Casualty testing.

Note 5: For these cartridge types only, if they contain a multi-option fuze where the only options are Point Detonate and Delay, they shall be set to Point Detonate during LAT.

Note 6: A function failure shall be defined as:

a) A cartridge that will not load into the weapon.

b) A misfire.

c) A short round.

d) HE cartridges only: A cartridge that does not completely detonate upon initial impact with their target. Self-destruct detonation or fuze function only shall be scored as a function failure, if shot as part of a function test.

e) Practice (Live) cartridges only: A cartridge that has an early function, or a failure to function before impact with the ground or target that does not expose user to smoke, blast, fire or fragmentation.

f) A cartridge that does not perform its primary function such as penetration, airburst, proximity, etc.

g) Smoke cartridges only: A cartridge that does not produce specified volume of smoke or has early function that does not expose user to smoke, blast, fire or fragmentation.

h) Illumination cartridges only: A cartridge that does not produce light for specified intensity, wavelength, duration and height or has early function that does not expose user to fire, blast or fragmentation.

Note 7: Critical safety failures are listed in section 4.5 of this specification.

ANNEX B - Operating Requirements

Spin Stabilized Grenades

Item3,4

Muzzle

Velocity1

(m/s)

Max. Average

Pressure1,2

(MPa)

Max.

Effective Range1

(m)

Lethal Fragmentation

Radius1

(m)

40mm HE Frag (VOG-25)

≥ 70 ≤ 85

≥ 400 ≥ 5

40mm HE Frag Bounding

(VOG-25P)

40mm HE Frag Airburst

40mm Illumination

40mm GRD-40 Smoke ≥ 50 -

Note 1: A minimum of 10 data points shall be required for each test parameter, however, it is permissible to leverage the same rounds to satisfy more than one requirement.

Note 2: Pressure can be measured during LAT or in process during charge establishment.

Note 3: For Practice cartridges: Pressure, Velocity, and Effective Range shall be per the manufacturers requirements unless specified by the Government in the proposals.

Note 4: Safety failures are listed in section 4.5 of this specification.

ANNEX B - Operating Requirements (continued)

Rocket Propelled Grenades

Item4,5

Muzzle

Velocity1

(m/s)

Max. Average

Pressure1,2

(MPa)

Max.

Effective Range1

(m)

Lethal Frag.

Radius1 (m)

Armor

Penetration3

(mm)

40mm HE/FRAG

(OG-7V)

≥ 145

≤ 95

≥ 950 ≥ 15 -

40mm HEAT

(PG-7V)

≥ 110 ≥ 350 - ≥ 260

40mm HEAT

(PG-7VM)

≥ 135 ≥ 450 - ≥ 200

40mm HEAT

(PG-7VL)

≥ 105 ≥ 250 - ≥ 400

73mm HE

(OG-9V)

≥ 310 ≤ 60 ≥ 450 ≥ 15 -

73mm HEAT

(PG-9V)

≥ 430 ≤ 67 ≥ 800 - ≥ 300

Note 1: A minimum of 10 data points shall be required for each test parameter, however, it is permissible to leverage the same rounds to satisfy more than one requirement.

Note 2: Pressure can be measured during LAT or in process during charge establishment.

Note 3: Not less than 80% of the Armor piercing ammunition (10 shot minimum) shall have full penetration of armor.

Note 4: For Practice cartridges: Pressure, Velocity, and Effective Range shall be per the manufacturers requirements unless specified by the Government in the proposals.

Note 5: Safety failures are listed in section 4.5 of this specification.

ANNEX C – Grenade Visual Inspection Requirements

Critical: 24-0-12,3 Major: 24-1-22,3

Re-inspection: 72-3-4 (cumulative)1,3

Minor (24-3-4)2,3

Re-inspection: 72-9-10 (cumulative)1,3

Missing, cracked, loose or bent parts Cases with moving cartridges; loose pack Discolored, oily, dirty, or smeared

Gross Corrosion, Pitting, or deformation

Incorrect quantity of cartridges in packaging (light boxes shall have their corners painted) each cartridge missing shall constitute one failure

Minor surface corrosion

Spillage/leakage of energetic materials Wire Security Seal missing Dents, chips or burrs

Incorrect Marking of cartridge type: HE cartridge marked as Inert, Practice or

Smoke

Mixed ammunition types: Training cartridge mixed with Combat cartridge lot Scratches on cartridge

Mixed ammunition types: Combat cartridge mixed with training cartridge lot

Missing, illegible or incorrect marking Excessive grease on cartridge

Incorrect Marking of cartridge type: Any cartridge type other than HE Irregular disposition of cartridges in case

Paint damaged, wet or incomplete

Note 1: If the number of allowable defects is exceeded a double sample quantity shall be re-inspected. The accept/reject criteria is based on the cumulative number of defects for all three samples.

Note 2: If a critical is found or the number of allowable majors or minors, after re-inspection, is exceeded the lot fails.

Note 3: The inspection and re-inspection quantity listed is selected during LAT. DCMA will utilize their Zero-Based Acceptance

Sample Plans shown in Appendix during GSI.

APPENDIX

1. DEFINITIONS

1.1 PdD SAWS Rocket Propelled and Spin Stabilized Grenade Ammunition. PdD SAWS rocket propelled and spin stabilized grenade munitions are those munitions that have not been safety tested and type classified for Army use, cannot be procured through the Army supply. Munitions and explosives that are not managed by National Inventory Control Points, have not been safety tested nor type classified for Army use, do not have a national stock number (NSN) and cannot be procured or requisitioned through the Army or other Department of Defense supply system.

1.2 Technical data. Technical data, otherwise known as the technical data package (TDP) is the product specific technical drawings and Quality Assurance (QA) requirements to which ammunition and associated packaging is produced and accepted for each applicable Contract Line Item Number (CLIN).

For the purpose of this specification, the TDP, as a minimum, must contain the following: Government contract number and delivery order; top assembly, fuze and key component drawings with revision number, revision date, document control signature, key interface dimensions, and a list of component assemblies with drawing numbers and revision dates; packaging and marking drawings with revision number, revision date, document control signature and markings; and product specification with final assembly, fuze and key component in-process acceptance test methods with sample size, and accept/reject criteria. Within the TDP there shall also be a clear cut-away and/or exploded drawing(s) to show all of the inner parts and workings of the fuze. Additionally, there shall be paragraphs which describe the fuze arming sequence and events leading to function. A copy of the manufacturers firing tables for ammunition shall be included with the TDP if available.

1.3 Degradation. Ammunition with gross nonconformance to identified technical requirements, corrosion, cracks, deformation, and spillage.

1.4 Deterioration. Packaging ripped, broken, perforated, with water damage, crushed.

1.5 Skip-Lot Temperature Extreme Testing. Testing at the operational temperature limits shall be conducted on the first lot of every delivery order and every 5th lot thereafter (1, 5, 10, 15…). The ammunition must pass the requirements defined in ANNEX A. If a lot is rejected for any reason, the following two lots must pass temperature testing before resuming the skip lot procedures.

APPENDIX (continued)

Acceptable Quality Level (AQL)

LOT SIZE 0.01 0.015 0.025 0.04 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10.0

1-8 A A A A A A A A A A A A 5 3 3 3

9-15 A A A A A A A A A A 13 8 5 3 3 3

16-25 A A A A A A A A A 20 13 8 5 3 3 3

26-50 A A A A A A A A 32 20 13 8 7 7 5 3

51-90 A A A A A A 80 50 32 20 13 13 11 8 5 4

91-150 A A A A A 125 80 50 32 20 19 19 11 9 6 5

151-280 A A A A 200 125 80 50 32 29 29 19 13 10 7 6

281-500 A A A 315 200 125 80 50 48 47 29 21 16 11 9 7

501-

A 800 500 315 200 125 80 75 73 47 34 27 19 15 11 8

1201-

1250 800 500 315 200 125 120 116 73 53 42 35 23 18 13 9

3201- 10,000

1250 800 500 315 200 192 189 116 86 68 50 38 29 22 15 9

10,001- 35,000

1250 800 500 315 300 294 189 135 108 77 60 46 35 29 15 9

35,001- 150,000

1250 800 500 490 476 294 218 170 123 96 74 56 40 29 15 9

150,001- 500,000

1250 800 750 715 476 345 270 200 156 119 90 64 40 29 15 9

500,001

Over 1250 1200 1112 715 556 435 303 244 189 143 102 64 40 29 15 9

Note: An "A" in place of a number indicates that all units in a lot must be inspected

File details come from the government source that posted it. Updated .