About this file
This is a quotation solicitation issued by West Basin Municipal Water District, a public agency serving 17 cities and nearly one million residents in coastal Los Angeles, California, for the supply and delivery of three ChargePoint model CT4021-GW1 Level 2 commercial electric vehicle chargers to be installed at the Edward C. Little Water Recycling Facility in El Segundo, California. The solicitation requires bidders to supply dual-port bollard-mounted charging stations featuring SAE J1772 connectors, 7.2 kW per port output at 30-ampere capacity, integrated LTE modems for cloud-based operation, ground fault detection, and surge protection rated at 6 kV @ 3,000 A. Each charging station must include a bollard concrete mounting kit and activation fee. The chargers must comply with UL 2594, UL 2231-1, UL 2231-2, NEC Article 625, and Energy Star standards and operate across temperature ranges of -40°C to 50°C. Electronic quotations must be submitted through https://procurement.opengov.com/portal/westbasin by April 23, 2026 at 2:00 pm, with a deadline for submitting questions and comments on April 16, 2026 at 4:00 pm. All quotations must remain valid for a minimum of 90 days from the closing date.
Pricing is subject to 9.5% sales tax, with payment terms established at net 30 days from receipt of correctly completed invoices submitted to invoices@westbasin.org, and all goods shipped prepaid F.O.B. destination. West Basin encourages participation from Small Business Enterprises (SBEs) and Local Business Enterprises (LBEs), offering evaluation scoring adjustments of 3% for SBEs or LBEs as prime contractors, 6% for bidders qualifying as both SBE and LBE, and 1% for prime contractors utilizing SBE or LBE subcontractors receiving at least 30% of total contract compensation. All bidders must comply with Build America, Buy America Act requirements mandating 65% domestically sourced components, provide proof of appropriate business licenses and certifications, maintain comprehensive insurance coverage including $2,000,000 general liability and $1,000,000 pollution liability, and provide full indemnification of the District. Optional prepaid three-year commercial cloud plans and assure maintenance and management plans are available. The award will be made to the lowest responsive quotation, subject to West Basin's Board of Directors approval.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ChargePoint® CT4000 Level 2 Commercial Charging Station Specifications and Ordering Information
CT4021
ChargePoint, Inc. | Copyright © 2025
ChargePoint, Inc. reserves the right to alter product offerings and specifications at any time without notice and is not responsible for typographical or graphical errors that may appear in this document.
Ordering Information The order codes below represent specific product configurations. Other product options are available.
Please contact ChargePoint Sales for information and order codes.
Hardware Description Order Code Model
1830 mm (6 ft) Single Port Bollard Mount
CT4011-GW1
1830 mm (6 ft) Dual Port Bollard Mount CT4021-GW1
1830 mm (6 ft) Single Port Wall Mount CT4013-GW1
1830 mm (6 ft) Dual Port Wall Mount CT4023-GW1
2440 mm (8 ft) Dual Port Bollard Mount CT4025-GW1
2440 mm (8 ft) Dual Port Wall Mount CT4027-GW1
1830 mm (6 ft) Single Port Bollard Mount with a Cut Resistant Cable
CT4011-GW1-CR
1830 mm (6 ft) Dual Port Bollard Mount with Cut Resistant Cables
CT4021-GW1-CR
1830 mm (6 ft) Single Port Wall Mount with a Cut Resistant Cable
CT4013-GW1-CR
1830 mm (6 ft) Dual Port Wall Mount with Cut Resistant Cables
CT4023-GW1-CR
Misc Power Management Kit CT4000-PMGMT
Bollard Concrete Mounting Kit CT4001-CCM
*Note: ALL CT4000 stations include Integrated Modem -GW1.
Software & Services ChargePoint CT4000 requires purchase of separate activation to initialize a station. ChargePoint CT4000 requires a cloud plan to operate. ChargePoint offers various service plans including extended parts warranties, ChargePoint Assure®, and customer managed labor plans.
ChargePoint, Inc. reserves the right to alter product offerings and specifications at any time without notice and is not
Architectural Drawings (Dimensions)
CT4021 1830 mm (6')
CT4025 2440 mm (8')
Bollard
CT4023 1830 mm (6')
CT4027 2440 mm (8')
Wall Mount
289 mm (11.4 in) 470 mm
(18.5 in)
302 mm (11.9 in)
483 mm (19.0 in)
347 mm (13.7 in)
CT4025
2426 mm (95.5 in)
233 mm (9.2 in)
CT4021
2426 mm (95.5 in) mm
347 mm (13.7 in)
233 mm (9.2 in) mm
CT4023
mm
(71.3 in)
CT4027
2426 mm (95.5 in)
ChargePoint, Inc. reserves the right to alter product offerings and specifications at any time without notice and is not
General Specifications
Electrical
Input
Single Port (AC Voltage 208/240 V
AC)
Dual Port (AC Voltage 208/240 V
AC)
Input Current
Input Power
Connection
Required Service Panel
Breaker Input
Current
Input Power
Connection
Required Service Panel
Breaker Standard 30 A One 40 A branch circuit
40A dual pole (non-GFCI type)
30 A x
Two independent 40A branch circuits
40 A dual pole (non- GFCI type) x
Standard Power Share n/a n/a n/a 32 A One 40 A branch circuit
40 A dual pole (non- GFCI type)
Power Select 24 A
24 A One 30 A branch circuit
30 A dual pole (non-GFCI type)
24 A x
Two independent 30A branch circuits
30 A dual pole (non- GFCI type) x
Power Select 24 A Power Share n/a n/a n/a 24A One 30 A branch circuit
30 A dual pole (non- GFCI type)
Power Select 16 A
16 A One 20 A branch circuit
20 A dual pole (non-GFCI type)
16 A x
Two independent 20 A branch circuits
20 A dual pole (non- GFCI type)
Power Select 16 A Power Share n/a n/a n/a 16 A One 20 A branch circuit
20 A dual pole (non- GFCI type)
Service Panel
GFCI
Do not provide external GFCI as it may conflict with internal GFCI (CCID)
Wiring – Standard
3-wire (L1, L2, Earth) 5-wire (L1, L1, L2, L2, Earth)
Wiring – Power Share n/a 3-wire (L1, L2, Earth)
Station Power 8 W typical (standby), 15 W maximum (operation)
ChargePoint, Inc. reserves the right to alter product offerings and specifications at any time without notice and is not
Line to Ground Voltage
120V +/- 10%
Electrical Output Electrical Output Single Port
(AC Voltage 208 / 240 V
AC)
Dual Port (AC Voltage 208 / 240 V AC)
Standard 7.2 kW (240V AC @ 30 A) 7.2 kW (240V AC @ 30 A) x 2
Standard Power Share n/a 7.2 kW (240 V AC @ 30 A) x 1 or
3.8 kW (240 V AC @ 16 A) x 2
Power Select 24 A 5.8 kW (240 V AC @ 24 A) 5.8 kW (240 V AC @ 24 A) x 2
Power Select 24 A Power Share n/a 5.8 kW (240 V AC @ 24 A) x 1 or
2.9 kW (240 V AC @ 12 A) x 2
Power Select 16A 3.8 kW (240 V AC @ 16A) 3.8 kW (240 V AC @ 16 A) x 2
Power Select 24 A Power Share n/a 3.8 kW (240 V AC @ 16 A) x 1 or
1.9 kW (240 V AC @ 8 A) x 2
Functional Interfaces Single Port
(AC Voltage 208 / 240 V AC) Dual Port
(AC Voltage 208 / 240 V AC) Connector(s) Type SAE J1772™ SAE J1772™ x 2
Cable Length - 1830 mm (6 ft) Cable Management
5.5 m (18 ft) 5.5 m (18 ft) x 2
Overhead Cable Management System
Yes
LCD Display 145 mm (5.7 in) full color, 640 x 480, 30 fps full motion video, active matrix, UV protected
Authentication and Payment
RFID: ISO 15693, ISO 14443
Virtual RFID NFC (Tap to Charge)
ChargePoint, Inc. reserves the right to alter product offerings and specifications at any time without notice and is not
Contactless credit card
Virtual Contactless credit card Apple Pay Google Pay
Remote: Mobile App and In Vehicle Dash (if supported by vehicle)
Locking Holster Yes Yes x 2
Safety and Connectivity Features Ground Fault Detection 20 mA CCID with auto retry
Open Safety Ground Detection Continuously monitors presence of safety (green wire) ground connection
Plug-Out Detection Power terminated per SAE J1772™ specifications
Power Measurement Accuracy +/- 2% from 2% to full scale (30 A)
Power Report/Store Interval 15 minutes, aligned to hour
Wide Area Network LTE Category 4
Supported Communication Protocols OCPP 2.0.1
Network All stations include integral LTE modem
Safety and Operational Ratings Station Enclosure Rating Type 3R per UL 50E
Safety and Compliance UL listed and cUL certified; complies with UL 2594, UL 2231-1, UL 2231-2, NEC Article 625, CTEP/NTEP, and Energy Star
Station Surge Protection 6 kV @ 3,000 A. In geographic areas subject to frequent thunderstorms, supplemental surge protection at the service panel is recommended.
Short Circuit Current Rating 5 kA
EMC Compliance FCC Part 15 Class A
Operating Temperature -40 °C to 50 °C (-40 °F to 122 °F)
Storage Temperature -40 °C to 60 °C (-40 °F to 140 °F)
Non-Operating Temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating Humidity Up to 85% @ 50 °C (122 °F) non-condensing
ChargePoint, Inc. reserves the right to alter product offerings and specifications at any time without notice and is not
Non-Operating Humidity Up to 95% @ 50 °C (122 °F) non-condensing
Terminal Block Temperature Rating
105 °C (221 °F)
ChargePoint, Inc. reserves the right to alter product offerings and specifications at any time without notice and is not
Other Specifications
Station Weight Wall Mount: 33.0 kg (72.7 lb) Bollard Mount: 46.6 kg (102.7 lb)
Standard Warranty Limited 2-Year Parts Warranty
Contact Us
ChargePoint, Inc.
240 East Hacienda Avenue
Campbell, CA 95008-6617 USA
+1.408.841.4500 or +1.877.370.3802 US and Canada toll-free
Visit chargepoint.com
Call +1.408.705.1992
Email sales@chargepoint.com
Copyright © 2025 ChargePoint, Inc. All rights reserved. CHARGEPOINT is a U.S. registered trademark/service mark, and an EU registered logo mark of ChargePoint, Inc. All other products or services mentioned are the trademarks, service marks, registered trademarks or registered service marks of their respective owners. May 2025 http://www.chargepoint.com/ mailto:sales%40chargepoint.com?subject=
| Ordering Information |
| Hardware |
| Software & Services |
| Architectural Drawings (Dimensions) |
| General Specifications |
| Electrical Output |
| Functional Interfaces |
| Safety and Connectivity Features |
| Safety and Operational Ratings |
| Other Specifications |