This document is a fixed cost pricing schedule for the City of Toledo's Lead-Based Paint Hazard Control Grant Program in Ohio. The file establishes pricing terms for lead abatement services to be provided under contracts awarded through the City's PlanetBids electronic bidding system. All bids must be submitted electronically through PlanetBids, with prices quoted to two decimal places and only one price per line item accepted. Bidders are required to submit comprehensive documentation including a signed contract, tax exemption certificate, contractor capacity affidavit, and current State of Ohio Lead Abatement Contractor License. Additional city paperwork required from new vendors includes vendor registration and business tax registration forms. The City requires notarized child support affidavits and vendor utility documentation to be submitted once for the duration of all 2026 contracts, with any changes to company information subject to notification requirements.
The pricing structure operates on a fixed cost basis for specified line items related to lead hazard control activities. Annual documentation requirements include a W-9 form, insurance certificates naming the City of Toledo as an additional insured, EEO compliance documentation, debarment certification, and a living wage affidavit updated no later than February 1st. Contractors must also maintain current Bureau of Workers Compensation documentation. The contract requires compliance with prevailing wage and insurance requirements as detailed in PlanetBids documents. No specific set-asides are identified in this pricing schedule, and the document serves as the basis for establishing fixed rates applicable to awarded contracts under the Lead-Based Paint Hazard Control Grant Program throughout 2026.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Lead Based Paint Hazard Control Grant
Fixed Cost Pricing September 2026
One Government Center, Suite 1800 Toledo, Ohio 43604
Office: (419) 245-1400
Fax: (419) 245-1192
CITY OF TOLEDO
Dept. of Housing and Community Development
Fixed Cost Pricing Schedule
1 1 SF @ $5.94 $5.94
2 1 SF @ $3.10 $3.10
3 1 SF @ $11.56 $11.56
4 1 LF @ $16.50 $16.50
5 1 EA @ $1,650.00 $1,650.00
Lead
Location:
Install New Gutters and Downspouts
Per HUD Lead Safe Housing requirements, industry standards and local codes - install new white aluminum seamless gutters and down spouting with 36", hinged extensions where possible. No straps are to be exposed above roofing, if possible.
Lead
Location:
Replace Window System with Vinyl Unit-Large
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing window and install new vinyl insulated replacement window with screen, hardware, and caulking as necessary. Include any trim and repair to interior walls to bring to original condition. Include aluminum coil stock on casings and sill. Ensure sill extends past the J- channel a minimum of 1/2".
Lead
Lead
Location:
Install 7/16” O.S.B Sheathing Complete
Per HUD Lead Safe Housing requirements, industry standards and local codes - Install new 7/16" exterior grade O.S.B. sheathing nailed with 8d commons across rafters.
Lead
Location:
Repair Sheathing and Shingles
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove damaged shingles and sheathing as needed and install new materials to match existing as close as possible. Include rafter repair as needed. Ensure leak has been eliminated prior to performing associated LEAD work.
Location:
Remove Existing Roofing Material and Install New
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove all roof covering down to sheathing, haul away debris. Minimal repair or replacement of rafters and/or roof sheathing. Install ice guard, 15Ib felt, new aluminum drip edge on rake and eaves, boot flashing on vent stacks, roof venting system (ridge or square), kick out flashing on sidewalls as needed, new metal flashing and counter flashing on chimney and along vertical walls to code. Install self-sealing 30yr, minimum, "Architectural" style shingles, in color of owner’s choice.
Page 2 9/11/2026
6 1 EA @ $1,760.00 $1,760.00
7 1 EA @ $1,320.00 $1,320.00
8 1 EA @ $1,430.00 $1,430.00
9 1 EA @ TBD TBDLead
Location:
Lead
Location:
Replace Window System with Vinyl Safety Glass Unit-Large
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing window and install new vinyl insulated replacement safety glass window with screen, hardware, and caulking as necessary. Include any trim and repair to interior walls to bring to original condition. Include aluminum coil stock on casings and sill.
Ensure sill extends past the J- channel a minimum of 1/2".
Lead
Location:
Replace Window System with Vinyl Safety Glass Unit-Average
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing window and install new vinyl insulated replacement safety glass window with screen, hardware, and caulking as necessary. Include any trim and repair to interior walls to bring to original condition. Include aluminum coil stock on casings and sill.
Ensure sill extends past the J- channel a minimum of 1/2".
Replace Window with Wood/Vinyl Clad Unit-Large
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing window and install new wood, vinyl clad insulated replacement window with screen, hardware, and caulking as necessary, to code. Include any trim and repair to interior walls to bring to original condition. Include aluminum coil stock on casings and sill. Ensure sill extends past the J-channel a minimum of 1/2".
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing window and install new vinyl insulated replacement window with screen, hardware, and caulking as necessary. Include any trim and repair to interior walls to bring to original condition. Include aluminum coil stock on casings and sill. Ensure sill extends past the J- channel a minimum of 1/2".
Lead
Location:
Replace Window System with Vinyl Unit-Average
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing window and install new vinyl insulated replacement window with screen, hardware, and caulking as necessary. Include any trim and repair to interior walls to bring to original condition. Include aluminum coil stock on casings and sill. Ensure sill extends past the J- channel a minimum of 1/2".
Page 3 9/11/2026
10 1 EA @ TBD TBD
11 1 EA @ $880.00 $880.00
12 1 EA @ $385.00 $385.00
13 1 EA @ $660.00 $660.00Lead
Location:
Replace Basement Window/Glass Block
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing window system to masonry foundation, dispose of all debris and install new glass block window with vent screen and dryer exhaust hole (as needed). Clean excess mortar from frame and glass as needed.
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing window and install new wood, vinyl clad insulated replacement window with screen, hardware, and caulking as necessary, to code. Include any trim and repair to interior walls to bring to original condition. Include aluminum coil stock on casings and sill. Ensure sill extends past the J-channel a minimum of 1/2".
Lead
Location:
Replace Window with Wood/Vinyl Clad Unit-Average
Lead
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing window and install new wood, vinyl clad insulated replacement window with screen, hardware, and caulking as necessary, to code. Include any trim and repair to interior walls to bring to original condition. Include aluminum coil stock on casings and sill. Ensure sill extends past the J-channel a minimum of 1/2".
Lead
Location:
Install Jamb Liners
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove and dispose of existing window stops, parting strips, strip lead based paint from friction points of lower sash, install jamb liners, reinstall lower sash reusing existing pulley system. Repair/replace any defective or missing materials (sash ropes/weights/locks) with new to match existing. Prime and finish interior and exterior of window system to match existing finishes.
Location:
Secure and Paint Stabilize Window System
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape peeling and loose paint from the exterior window, prime bare areas and apply one coat of exterior grade, semi-gloss, white, latex paint. Include casings and sill.
Page 4 9/11/2026
14 1 EA @ $220.00 $220.00
15 1 EA @ $1,760.00 $1,760.00
16 1 EA @ $2,200.00 $2,200.00
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing entrance door, jamb, trim and sill, and dispose of all debris. Provide and install, primed, pre-hung steel, insulated, (insert style here- half lite, full lite, fan lite, flush, etc.), exterior 1-3/4" entry door with trim. Include keyed lockset, dead-bolt and doorstop. Include any repair to interior walls to bring to original condition. Infill gaps between existing siding and new brick molding as needed. Include aluminum coil stock on casings. $450.00 allowance for the door, deadbolt and handle (standard size).
Ensure no gaps exist between weather strip and door, adjust threshold as needed to close gaps and fully support threshold so no "flex" exists. If more than one door is being replaced, key all doors alike. Owner to paint.
Lead
Lead
Location:
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove the existing storm door and entrance door, jamb, trim and threshold, and dispose of all debris. Provide and install primed, pre-hung, steel, insulated raised panel, exterior 1-
3/4" solid core door with light panel of owners choice. Include exterior and interior trim, keyed lockset, doorstop, dead bolt. Include any repair to interior and exterior walls to bring to original condition. Include aluminum coil stock on casings. Ensure no gaps exist between weather strip and door, adjust threshold as needed to close gaps and fully support threshold so no "flex" exists. $450.00 allowance for the door, deadbolt and handle.
Provide and install white, prefinished aluminum storm door with screen and storm window to code. Swing to complement exterior door. Caulk where necessary. $250 allowance for storm door.
Location:
Replace Exterior Door System Including Storm
Paint Stabilize Basement Window
Per HUD Lead Safe Housing requirements, industry standards and local codes - replace broken glass as needed, wet scrape peeling and loose paint from the exterior window, prime bare areas, caulk all gaps and apply one coat of exterior grade, semi-gloss, white, latex paint. Include casings and sill.
Lead
Location:
Replace Exterior Door System
Page 5 9/11/2026
17 1 EA $1,880.00 $1,880.00
18 1 EA @ $440.00 $440.00
19 1 EA @ $165.00 $165.00
20 1 EA @ $385.00 $385.00
Location:
Enclose Existing Exterior Threshold
Per HUD Lead Safe Housing requirements, industry standards and local codes - enclose the exposed portion of the existing threshold with 1/4" plywood, caulk gaps, fill nail holes, prime bare wood and apply one coat of semi-gloss, exterior, latex based, paint.
Lead
Lead
Location:
Replace Exterior Door System and Re-Install Storm
1) Per HUD Lead Safe Housing requirements, industry standards and local codes -remove the existing storm door (save for reinstallation) and entrance door, jamb, trim and threshold. Provide and install primed, pre-hung, steel, insulated raised panel, exterior 1-3/4" solid core door with light panel of owners choice. Include exterior and interior trim, keyed lockset, doorstop, dead bolt. Include any repair to interior and exterior walls to bring to original condition. Include aluminum coil stock on casings.
Ensure no gaps exist between weather strip and door, adjust threshold as needed to close gaps and fully support threshold so no "flex" exists. $450.00 allowance for the door, deadbolt and handle.
2) Re-install storm door.
Lead
Lead
Location:
Replace Storm Door
Per HUD Lead Safe Housing requirements, industry standards and local codes - Provide and install white, prefinished aluminum storm door with screen and storm window to code. Swing to complement exterior door. Caulk where necessary. $250.00 allowance for storm door.
Location:
Paint Stabilize Exterior Door System
Per HUD Lead Safe Housing Requirements, industry standards and local codes - wet sand or wet plane as needed for friction free operation, prime bare surfaces, caulk all gaps and apply one coat of exterior grade, white, latex, semi-gloss paint. Install foam weather stripping on stops to prevent impact.
Page 6 9/11/2026
21 1 EA @ $1,422.00 $1,422.00
22 1 EA @ $1,941.00 $1,941.00
23 1 SF @ $2.86 $2.86
24 1 SF @ $1,430.00 $1,430.00
25 1 SF @ $11.00 $11.00
Per HUD Lead Safe Housing requirements, industry standards and local codes - install vinyl siding and all necessary trim pieces on entire structure. Consult with homeowner on style and color. Standard colors only.
Lead
Location:
Paint Stabilize Existing Painted Siding and Trim
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape all peeling and loose paint from exterior siding, prime bare wood, caulk all gaps and apply one coat of exterior grade, latex, semi-gloss paint.
Per HUD Lead Safe Housing requirements, industry standards and local codes - enclose the exterior siding with "house wrap" using approved fasteners and tape to create a dust free barrier. Surface prep all exterior surfaces to accommodate new vinyl siding prior to the application of house wrap.
Lead
Location:
Enclose Exterior Components with Vinyl and Aluminum
Per HUD Lead Safe Housing Requirements, industry standards and local codes - install overhead insulated type with galvanized hardware, torsion or extension springs and sectioned door. Include new weather strip. Owner to have input on color and style of door. Standard colors only. Verify size before ordering.
Lead
Location:
Enclose Exterior Components with House Wrap
Location:
Replace Overhead Garage Door System – 1 car
Per HUD Lead Safe Housing Requirements, industry standards and local codes - install overhead insulated type with galvanized hardware, torsion or extension springs and sectioned door. Include new weather strip. Owner to have input on color and style of door. Standard colors only. Verify size before ordering.
Lead
Location:
Replace Overhead Garage Door System – 2 car
Per HUD Lead Safe Housing Requirements, industry standards and local codes - wet sand or wet plane as needed for friction free operation, prime bare surfaces, caulk all gaps and apply one coat of exterior grade, white, latex, semi-gloss paint. Install foam weather stripping on stops to prevent impact.
Lead
Page 7 9/11/2026
26 1 SF @ $11.00 $11.00
27 1 SF @ $17.80 $17.80
28 1 SF @ $14.30 $14.30
29 1 SF @ $9.90 $9.90
30 1 LF @ $53.36 $53.36
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape all peeling and loose paint, prime bare areas, caulk all gaps and apply one coat of exterior grade, latex, semi-gloss, "porch and floor" paint. Install outdoor carpet, $2.00sf allowance. Standard colors only.
Lead
Location:
Replace Porch Railing System
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove existing railing system and install new, pressure treated system.
NOTE: Assume the following:
2"x6" top rail 2"x4" bottom rail
Enclose Decking w/ Treated Plywood and Outdoor Carpet
Per HUD Lead Safe Housing requirements, industry standards and local codes - enclose the existing wood floor with exterior grade, treated plywood. Fill all seams and caulk perimeter.
Ensure edges of existing flooring are enclosed. Install outdoor carpet, $2.00sf allowance.
Standard colors only.
Lead
Location:
Paint Stabilize Porch Deck and Outdoor Carpet
Location:
Replace Porch Flooring w/ T&G Material
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove existing porch flooring to floor joists, repair/re-secure floor joists, add blocking as needed for porch posts and install new tongue and groove Douglas Fir or treated flooring. Owner to paint.
Lead
Location:
Lead
Location:
Paint Stabilize Foundation
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape all peeling and loose paint from exterior siding, prime bare wood, caulk all gaps and apply one coat of exterior grade, latex, semi-gloss paint. Color to be determined.
Lead
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape all peeling and loose paint from exterior siding, prime bare wood, caulk all gaps and apply one coat of exterior grade, latex, semi-gloss paint.
Page 8 9/11/2026
31 1 LF @ $9.19 $9.19
32 1 EA @ $355.00 $355.00
33 1 EA @ $577.00 $577.00
34 1 EA @ $221.00 $221.00
35 1 EA @ $177.00 $177.00
Per HUD Lead Safe Housing requirements, industry standards and local codes - enclose porch post with custom bent aluminum.
Lead
Location:
Paint Stabilize Porch Post
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape all peeling and loose paint from post, repair as needed, prime bare areas, caulk all gaps and apply one coat of exterior grade, latex, semi-gloss paint.
Replace Porch Post and Enclose with Aluminum
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove existing post and install new, 1"x6" pine box post enclosed with custom bent aluminum.
Lead
Location:
Enclose Porch Post with Aluminum
Location:
Replace Porch Post
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove existing post and install new, pressure treated, 4"x4" porch post.
Lead
Location:
Lead
Location:
Paint Stabilize Porch Railing System
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape all peeling and loose paint from railing system, prime bare wood, caulk all gaps, apply one coat of exterior grade, latex, semi-gloss paint.
Lead
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove existing railing system and install new, pressure treated system.
NOTE: Assume the following:
2"x6" top rail 2"x4" bottom rail
Page 9 9/11/2026
36 1 EA @ $2,828.00 $2,828.00
37 1 SF @ $7.12 $7.12
38 1 SF @ $5.35 $5.35
39 1 SF @ $17.80 $17.80
40 1 EA @ $220.00 $220.00
Location:
Paint Stabilize Interior Window Trim
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet sand as needed, caulk all gaps, prime bare areas and paint stabilize window casings, stops, sill and apron. Owner to pick color and sheen.
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove visible paint chips, till soil from foundation to 3’ away from structure with a slope away from the foundation for water runoff, cover tilled soil with landscape cloth and apply 6" of mulch. Consult owner for color selection.
Lead
Lead
Lead in Soil – Concrete
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove contaminated soil from site, install stone and concrete. Slope away from foundation for drainage. Use expansion joints at foundation and existing concrete.
Location:
Lead in Soil – Plant Grass
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove visible paint chips, till soil, apply seed and straw. Owner responsible for watering new seeded areas.
Lead
Location:
Lead
Location:
Replace Stair System
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove and dispose of existing stair system as needed and replace with new treated lumber materials.
NOTE: Assume the following:
3'x3' landing mounted on 4"x4" support posts Railing system
3 each step
Lead
Location:
Lead in Soil – Mulch
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape all peeling and loose paint from post, repair as needed, prime bare areas, caulk all gaps and apply one coat of exterior grade, latex, semi-gloss paint.
Page 10 9/11/2026
41 1 EA @ $990.00 $990.00
42 1 EA @ $622.00 $622.00
43 1 EA @ $275.00 $275.00
44 1 SF @ $12.10 $12.10
45 1 SF @ $8.80 $8.80
Location:
Paint Stabilize Ceiling/Wall
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape peeling and loose paint, repair plaster as needed, spot prime bare areas and apply one coat of latex paint. Owner to pick color and sheen.
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet sand or wet plane as needed for friction free operation and caulk all gaps. Prime bare areas and apply one coat of interior, latex based paint. Install rubber bumpers on stops.
Lead
Location:
Enclose Ceilings/Walls with Drywall
Per HUD Lead Safe Housing requirements, industry standards and local codes - enclose ceiling and walls with drywall. Apply tape, finish, texture (as needed), one coat of latex primer and one coat of latex paint. Ensure all gaps abutting trim are caulked. Owner to pick color and sheen.
Lead
Location:
Replace Interior Door Slab and Stops
As per HUD Lead Safe Housing requirements, industry standards and local codes -remove existing door slab and stops and install new hollow core, raised panel, door and new stops. Install appropriate handle and door stop. Owner to paint.
Lead
Location:
Paint Stabilize Interior Door System and Rubber Bumpers
Lead
Location:
Replace Interior Door System
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove existing interior door/jamb/casing and install new hollow core, raised panel, pre-hung unit including casing. Install appropriate handle and door stop. Owner to paint.
Page 11 9/11/2026
46 1 LF @ $4.90 $4.90
47 1 LF @ $12.46 $12.46
48 1 EA @ $137.00 $137.00
49 1 EA @ $137.00 $137.00
50 1 LF @ $49.00 $49.00
Per HUD Lead Safe Housing requirements, industry standards and local codes -enclose stair risers with 1/4" luan plywood and caulk all gaps abutting treads and skirt boards.
Lead
Location:
Install Guardrail and Handrail
Per HUD Lead Safe Housing requirements, industry standards and local codes - replace existing guardrail system with new materials.
Location:
Install Vinyl Tread Covers
Per HUD Lead Safe Housing requirements, industry standards and local codes - install vinyl covers on all painted treads.
Lead
Location:
Enclose Stair Risers
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape peeling and loose paint, caulk all gaps, prime bare areas and apply one coat of latex paint. Owner to pick color and sheen.
Lead
Location:
Enclose Floor with ¼” Luan and Sheetgoods
Per HUD Lead Safe Housing requirements, industry standards and local codes - enclose the existing wood floor with 1/4" luan underlayment and new vinyl sheet goods, including shoe molding and threshold strips at all exposed flooring edges. Fill all seams and caulk perimeter to baseboards. $2.00sf allowance for sheet goods. Consult owner for product selection. Owner to prep and paint wood trim.
Lead
Per HUD Lead Safe Housing requirements, industry standards and local codes - wet scrape peeling and loose paint, repair plaster as needed, spot prime bare areas and apply one coat of latex paint. Owner to pick color and sheen.
Lead
Location:
Paint Stabilize Baseboard
Page 12 9/11/2026
51 1 LF @ $27.00 $27.00
52 1 LF @ $266.00 $266.00
53 1 LF @ $355.00 $355.00
54 1 all @ $355.00 $355.00
55 1 LF @ $17.00 $17.00
Location:
Replace Medicine Cabinet
Per HUD Lead Safe Housing requirements, industry standards and local codes - replace medicine cabinet and encapsulate any remaining trim.
Lead
Location:
Enclose Shelving
Per HUD Lead Safe Housing requirements, industry standards and local codes - replace upper cabinets and hardware.
All cabinets and hardware shall be chosen from in-stock, standard colors and styles, "Kitchen Kompact" or equal. Consult owner for style selections.
Lead
Location:
Per HUD Lead Safe Housing requirements, industry standards and local codes - paint stabilize all sides and enclose friction surfaces with self-adhesive shelf liner.
Replace Base Cabinet
Per HUD Lead Safe Housing requirements, industry standards and local codes - replace base cabinets and hardware.
All cabinets and hardware shall be chosen from in-stock, standard colors and styles, "Kitchen Kompact" or equal. Consult owner for selections.
Lead
Location:
Install Handrail Only
Per HUD Lead Safe Housing requirements, industry standards and local codes - install new handrail system and support brackets.
Lead
Location:
Replace Upper Cabinet
Per HUD Lead Safe Housing requirements, industry standards and local codes - replace existing guardrail system with new materials.
Page 13 9/11/2026
56 1 LF @ $33.00 $33.00
57 1 LF @ $70.00 $70.00
58 1 EA @ $1,650.00 $1,650.00
59 1 EA @ $2,750.00 $2,750.00
60 1 SF @ $4.15 $4.15
61 1 EA @ $420.00 $420.00
Location: All areas where work was performed and/or has lead dust hazards.
HUD Cycle Cleaning
Per HUD Lead Safe Housing Requirements, industry standards and local codes - perform
"HUD cycle cleaning" all affected areas.
Per HUD Lead Safe Housing requirements, industry standards and local codes - paint stabilize all sides and enclose friction surfaces with self-adhesive shelf liner.
Lead
Location:
Replace Shelving
Per HUD Lead Safe Housing requirements, industry standards and local codes - remove existing shelving and install new, pre-finished 1"x12" shelving.
Lead
Per HUD Lead Safe Housing Requirements, industry standards and local codes - build containment systems in accordance with work being performed.
Lead
Location: All work areas
Lead Containment – Two Story
Per HUD Lead Safe Housing Requirements, industry standards and local codes - build containment systems in accordance with work being performed.
Lead
Location:
Replace Counters
Per HUD Lead Safe Housing requirements, industry standards and local codes - replace counters with an in-stock, post-formed style with standard edging.
Lead
Location: All work areas
LEAD Containment – One Story
Healthy Homes
Location:
Replace Kitchen Sink
Per HUD Lead Safe Housing Requirements, industry standards and local codes -remove existing sink and replace with new double bowl stainless type at least 8 in. deep and new strainer baskets with stops. $175.00 allowance for sink, strainers and stops.
Page 14 9/11/2026
62 1 EA @ $315.00 $315.00
63 1 EA @ $420.00 $420.00
64 1 EA @ $525.00 $525.00
65 1 EA @ $1,365.00 $1,365.00
66 1 EA @ $4,935.00 $4,935.00
Per HUD Lead Safe Housing Requirements, industry standards and local codes - replace toilet with similar style, include new wax ring and supply line.
Healthy Homes
Location:
Replace Vanity with Sink and Faucet
Per HUD Lead Safe Housing Requirements, industry standards and local codes - remove existing sink and replace with new 30”-inch unit to code. Use Merillat Horizon or equal cabinet and preformed sink top. Include new washerless faucet of brass construction, supply lines, trap system, stopper and caulk. Repair wall to" paint ready " condition prior to installation.
Healthy Homes
Location:
Healthy Homes
Location:
Replace Kitchen Faucet
Per HUD Lead Safe Housing Requirements, industry standards and local codes -remove and dispose of existing kitchen sink, supply lines and trap system and replace with washerless faucets to code. Owner to have input on style of unit and a $150.00 allowance for faucet.
Healthy Homes
Location:
Replace Toilet
Replace Water Heater
Per HUD Lead Safe Housing Requirements, industry standards and local codes - remove and dispose of old unit and install new 40-gallon, natural gas, energy efficient unit attached to exiting vent pipe.
Healthy Homes
Location:
Install 90% Efficiency Power Vented Furnace
Per HUD Lead Safe Housing Requirements, industry standards and local codes - remove and dispose of old unit and install a new, properly sized, 90+% Power Vented AFUE, ENERGY STAR rated furnace and digital thermostat.
Page 15 9/11/2026
67 1 EA @ $4,410.00 $4,410.00
68 1 EA @ $150.00 $150.00
69 1 EA @ $150.00 $150.00
Per HUD Lead Safe Housing Requirements, industry standards and local codes - remove and dispose of old unit and install a new, properly sized, 80+% AFUE, ENERGY STAR rated furnace, flue liner as needed and digital thermostat.
Healthy Homes
Location:
Install 80% Efficient Furnace
Healthy Homes
Location: Basement, Living Rm, Hallways, Bedrooms
Install Wireless, Interconnected Smoke and Carbon Monoxide Detectors
Per HUD Lead Safe Housing Requirements, industry standards and local codes - install wireless, interconnected smoke and carbon monoxide detectors as follws: Smoke and carbon in basement and hallways outside of bedrooms; smoke in living room and bedrooms.
Location: Basement
Upgrade Existing Electrical Panel(s) to 200 Amp 40-Space 80 Circuit Panel
Per HUD Lead Safe Housing Requirements, industry standards and local codes - remove existing panel(s) and instal a new 200 Amp, 40 space, 80 circuit panel to code. Include all wiring, breakers, etc. Also include all work required to be upgraded per the City of
Toledo Electrical Department, i.e. smoke and carbon detectors, local plug, etc.
Healthy Homes
Page 16 9/11/2026
File details come from the government source that posted it. Updated .