This document is a suggested specification for the Pawling Pro-Tek® Model CG-10R corner guard system. The product is a 3" x 3" x 90° surface-mounted corner guard made of high-impact vinyl with a continuous recycled plastic retainer, a 1/4" radius snap-on plastic cover, and molded closure caps. Key technical specifications include Class A interior wall finish rating, stain resistance, bacterial and fungal growth resistance, and high impact strength.
The specification details precise material requirements, including an extruded high-impact vinyl cover with 0.100" thickness colored throughout, a recycled high-impact vinyl retainer with 0.070" thickness, and injection-molded thermoplastic closure caps. Installation requirements specify acclimating materials for 24 hours prior to installation, maintaining building temperatures between 65°-75°F, and following manufacturer's installation instructions. The product is designed to provide durable wall protection and can be selected in standard or custom colors from the manufacturer, Pawling Corporation, located in Wassaic, NY.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 12970 PWS.docx | DOCX document | |
| Solicitation - FA857925Q0012.pdf | ||
| CDRL A001 Safety.pdf | ||
| CDRL A002 - Mishap.pdf | ||
| Corner Guard info (4).pdf | ||
| Corner Guard info (3).pdf | ||
| Corner Guard info (1).pdf | ||
| WR-ALC Appendix C.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Architectural Products 800-431-3456/ www.pawling.com Page 1 WS.104.1
Suggested Specification
SECTION 10 26 13
Pawling Pro-Tek® Model CG-10R
PART 1 GENERAL
1.01 SUMMARY
A. This section includes the following wall protection system:
1. Corner Guards
B. Related Sections
1. Section 10 26 16 - Bumper Guards
2. Section 10 26 23 - Protective Wall Covering
3. Section 10 26 33 - Door and Frame Protection
4. Section 09 22 00 - Supports for Plaster and Gypsum Board
1.02 REFERENCES
A. Abbreviations and Acronyms
1. National Fire Protection Association (NFPA)
2. American Society for Testing and Materials (ASTM)
3. Underwriters Laboratories (UL)
4. American National Standards Institute (ANSI)
1.03 SUBMITTALS
A. General: Submit the following in accordance with Section 01 33 00 “Submittal
Procedures”.
B. Product Data
1. Data sheet illustrating product dimensions, options, and related components.
2. Installation instructions.
C. Samples for verification of design suitability, color, finish, accessory cap attachment and alignment.
1. 12” (304) Long sample with attached closure cap.
D. Test reports from a qualified independent laboratory showing results in compliance to requirements indicated
1.04 QUALITY ASSURANCE
A. Manufacturer to have no less than 5 years experience in the production of wall protection products having successful in-service performance.
B. Color Control: Provide extruded and molded components that meet visual and colorimetric evaluation of color to a controlled standard.
1. Colorimetric evaluation less than or equal to 1.0 CMC DE (Delta E) when measured under cool white fluorescent lighting.
1.05 DELIVERY, STORAGE, AND HANDLING
A. Storage: Store wall protection products in original packaging. Protect from weather, extreme temperatures, and moisture.
1. Maintain temperature during storage between 40°- 100°F (4°- 38°C).
2. Store materials flat to prevent twisting or sagging of cartons.
B. Handling: Take adequate measure to prevent damage to materials. Avoid exposure of plastic products to direct sunlight.
Architectural Products 800-431-3456/ www.pawling.com Page 2 WS.104.1
1.06 SITE CONDITIONS
A. Ambient Conditions: Do not install wall protection products until installation areas are enclosed and weatherproof. HVAC system must be operational and maintaining temperature at 65°-75°F (18°-24°C) for at least 72 hours prior to installation.
PART 2 PRODUCTS
2.01 MANUFATURERS
A. Pawling Corporation Architectural Products
32 Nelson Hill Rd Wassaic, NY 12592 Tel: 800-431-3456 www.pawling.com
2.02 DESCRIPTION
A. Model CG-10R, 3” (76) x 3” (76) x 90° Surface mounted corner guard system with a continuous recycled plastic retainer, 1/4” (6) radius snap-on plastic cover, and molded top and bottom closure caps. Select color from manufacturer’s standard or custom colors.
2.03 DESIGN AND PERFORMANCE CRITERIA
A. Flammability Characteristics: High impact vinyl components.
1. Class A Interior wall finish (NFPA 101 Life Safety) when tested in accordance with ASTM E84.
a. Flame Spread: 25 or less
b. Smoke Developed: 450 or less
2. Classification of HB when tested in accordance with ASTM D635.
B. Stain Resistance: High impact vinyl components.
1. Material to be tested for stain resistance to various chemical reagents in accordance with ASTM D543.
C. Bacterial and Fungal Growth: High impact vinyl components.
1. Material must not support bacteria or fungal growth when tested in accordance with ASTM G21 and ASTM G22.
D. Impact Resistance: High impact vinyl components.
1. Extruded profiles shall resist damage from impact at apex of 90° corner when tested in accordance with applicable sections of ASTM F476.
2. Izod impact strength ASTM D256 method A notched, 23.8 ft-lbs/in average with no break.
3. Charpy impact strength ASTM D6110 notched, 26.1 ft-lbs/in average with no break.
2.04 MATERIALS
A. Cover: Extruded high impact vinyl, nominal 0.100” (2.5) thickness, colored throughout.
B. Retainer: Extruded recycled high impact vinyl, nominal 0.070” (1.8) thickness.
C. Closure Caps: Injection molded thermoplastic.
Architectural Products 800-431-3456/ www.pawling.com Page 3 WS.104.1
PART 3 EXECUTION
3.01 EXAMINATION
A. Examine walls for availability of backing to ensure secure attachment of wall protection products.
B. Verify that HVAC is operating and installation area temperature has been maintained between 65°-75°F (18°-24°C) for at least 72 hours prior to installation.
C. Verify application of wall finishes has been completed in accordance with project finish plan.
3.02 PREPARATION
A. Surface Preparation: Clean substrate to remove dust and debris.
3.03 INSTALLATION
A. Acclimate materials to building conditions for at least 24 hours prior to installation.
B. Install wall protection products in accordance with manufacturer’s installation instructions.
3.04 PROTECTION
A. Protect installed material from damage by other trades. Use materials that will not mark, stain, or leave residue on the product.