This file is a comprehensive set of architectural and engineering design documents for the Durango-La Plata County Airport Terminal Expansion and Modernization - Phase 1B Concessions Request for Proposal (RFP), prepared by Mead & Hunt, Inc. The documents detail the design and specifications for food and beverage concession spaces in the airport terminal, covering landside and airside areas. The project involves creating multiple concession zones, including a landside food and beverage area, an airside bar/cafe, airside retail space, and an airside food and beverage south area. The design documents are dated September 6, 2024, with a conformed set issued on May 1, 2025, and include detailed architectural plans, electrical, mechanical, plumbing, fire protection, and technology system specifications.

The design documents provide extensive technical details for each concession space, including precise measurements, equipment layouts, electrical and plumbing requirements, and specific design considerations. The total area for these concession spaces ranges from approximately 225 to 592 square feet, with each area featuring specialized equipment such as coffee brewers, refrigeration units, food preparation stations, and point-of-sale areas. The plans indicate that while the airport will provide basic infrastructure like electrical connections, lighting, and basic plumbing, concessionaires will be responsible for providing their own equipment, finishes, and specific operational components. The design emphasizes flexibility for future tenant improvements and includes provisions for potential future modifications to the spaces.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEGEND - PLAN SYMBOLS

ROOM NAME AND NUMBER

WALL TYPE

IDENTIFICATION

KEYED NOTE IDENTIFICATION

WINDOW IDENTIFICATION

DOOR IDENTIFICATION

FLOOR DRAIN

4.XXX

DETAIL SYMBOL

EXTERIOR ELEVATION

SYMBOL

WALL SECTION SYMBOL

INTERIOR ELEVATION

SYMBOL

BUILDING SECTION SYMBOL

FD

FIRE EXTINGUISHER - SURFACE MOUNT

FIRE EXTINGUISHER CABINET AND FIRE

EXTINGUISHER - SEMI-RECESSED

1 HOUR FIRE RATED WALL

ROOM NAME

A-211

A-201

ENLARGED PLAN

SYMBOL

A

XXX

X' - X"

W?

A100

A100

A-101

SIM

A-101

SIM

XXX

X

A-101

A-101

A-101

A-101

F.E.C.

F.E.

EXISTING GRID LINES

NEW GRID LINES

LEVEL OR SPOT ELEVATIONS

ACP-X

10'-10" CEILING HEIGHT & FINISH

MATCHLINE

HATCH SYMBOLS

EARTHWORK

GRAVEL

PLASTER,

SAND, GROUT

CONCRETE

CONCRETE

MASONRY

CLAY

MASONRY

PRECAST

CONCRETE

METAL

PLYWOOD

FINISH LUMBER

WOOD STUDS,

BLOCKING

STEEL STUDS

GYPSUM

WALLBOARD

ACOUSTICAL

TILE

BATT

INSULATION

RIGID

INSULATION

ANGLE

@ AT

AB ANCHOR BOLT

AC ACOUSTIC

ACC ACCESS

ACT ACOUSTIC CEILING TILE

ACP ACOUSTIC CEILING PANEL

AD AREA DRAIN

ADD ADDITIONAL

ADJ ADJUSTABLE

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

AL ALUMINUM

ALT ALTERNATE

AP ACCESS PANEL

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASPH ASPHALT

BB BOND BEAM

BD BOARD

BF BOTH FACES

BFC BELOW FINISH CEILING

BG BUMPER GUARD

BIT BITUMINOUS

BLDG BUILDING

BLKG BLOCKING

BLKT BLANKET

BM BEAM/BENCH MARK

BLK BLOCK

BOT BOTTOM

BRG BEARING

BRKR BREAKER

BRK BRICK

BRKT BRACKET

BS BACK SPLASH

BSMT BASEMENT

BTWN BETWEEN

CHN CHANNEL

CAB CABINET

CER CERAMIC

CFCI CONTRACTOR FURNISHED,

CONTRATOR INSTALLED

CG CORNER GUARD

CH COAT HOOK

CIP CAST IN PLACE

CJ CONTROL JOINT/CONSTRUCTION

JOINT

CLG CEILING

CLO CLOSET/CLOSURE

CLR CLEAR

COL COLUMN

COMB COMBINATION

CMU CONCRETE MASONRY UNIT

CONC CONCRETE

CONF CONFERENCE

CONN CONNECTION/CONNECT

CONST CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACTOR

CORR CORRIDOR

CPT CARPET

CR COAT RACK/CURTAIN ROD

CSG CASING

CT CERAMIC TILE

CTR CENTER/COUNTER

CTSK COUNTERSUNK

CUH CABINET UNIT HEATER

CW COLD WATER

DAS DISTRIBUTED ANTENNA SYSTEM

D DEPTH

DBL DOUBLE

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DIR DIRECTION

DIV DIVISION

DM DEMOUNTABLE PARTITION

DN DOWN

DO DITTO

DR DOOR

DRWR DRAWER

DS DOWNSPOUT

DWG DRAWING

DWL DOWEL

DWS DEFORMED WELDED STUD

EA EACH

EC ELECTRICAL CONTRACTOR

EF EACH FACE

EH ELECTRICAL HEATER/EXHAUST

HOOD

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR/ELEVATION

EMBED EMBEDDED

EMER EMERGENCY

ENT ENTRANCE

EQ EQUAL

EQUIP EQUIPMENT

ES EMERGENCY SHOWER

ESR ELASTOMERIC SHEET ROOFING

ETR EXISTING TO REMAIN

EVC ELASTIC VINYL COATING

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXC EXCAVATE

EXP EXPANSION

EXPD EXPOSED

EXPF EXPLOSION PROOF

EXT EXTERIOR

FA FIELD ADJUSTABLE

FV FIELD VERIFY

FD FLOOR DRAIN

FDN FOUNDATION

FFE FINISHES, FURNITURE, EQUIPMENT

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FHC FIRE HOSE CABINET

FIN FINISH

FIX FIXTURE

FLEX FLEXIBLE

FLR FLOOR

FLRG FLOORING

FOM FACE OF MASONRY

FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR

FP FIREPROOF/FIRE PROTECTION

FR FIRE RETARDANT

FRP FIBERGLASS REINFORCED PANEL

FS FULL SIZE/FULL SCALE

FT FEET

FTG FOOTING

FURG FURRING

GA GAUGE

GAL GALLON

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GEN GENERAL

GFCI GOVERNMENT FURNISHED, CONTRACTOR INSTALLED

GFGI GOVERNMENT FURNISHED, GOVERNMENT INSTALLED

GFRC GLASS FIBER REINFORCED CONCRETE

GFRG GLASS FIBER REINFORCED GYPSUM

GL GLASS

GMU GLAZED MASONRY UNIT

GWB GYPSUM WALL BOARD

GYP GYPSUM

H HEIGHT

HDBD HARDBOARD

HDCP HANDICAPPED

HDWD HARDWOOD

HDWE HARDWARE

HK HOOK

HM HOLLOW METAL

HP HIGH POINT

HR HANDRAIL

HT HEIGHT

HVAC HEATING VENTILATION AND AIR CONDITIONING

HWS HEAD WELDED STUDS

ID INSIDE DIAMETER

IMP INSULATED METAL PANEL

IN INCHES

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

IPW INSULATED PLENUM WALL

IRF INSULATED ROOF FILL

JAN JANITOR

JS JANITOR SINK

JST JOIST

JT JOINT

KD KNOCKED DOWN

KO KNOCK-OUT / KNEE OPENING

L LENGTH

LAB LABORATORY

LAM LAMINATED

LB POUND

LBS POUNDS

LD LINEAR DIFFUSER

LDG LANDING

LF LINEAR FOOT

LG LONG

LGT LIGHT

LKR LOCKER

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LONG LONGITUDINAL

LP LOW POINT

LPS LIGHTNING PROTECTION SYSTEM

LSH LONG SLOTTED HOLE

LTG LIGHTING

LVR LOUVER

LWC LIGHTWEIGHT CONCRETE

MACH MACHINE

MAN MANUAL

MAR MARBLE

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MB MACHINE BOLT

MBW MASONRY BEARING WALL

MC MECHANICAL CONTRACTOR

MDO MEDIUM DENSITY OVERLAY

MECH MECHANICAL

MEMB MEMBRANE

MET METAL

MEZZ MEZZANINE

MFR MANUFACTURER

MIN MINIMUM

MIR MIRROR

MISC MISCELLANEOUS

MK MARK

ML METAL LATH

MLDG MOLDING

MO MASONRY OPENING

MP METAL PARTITION

MS MACHINE SCREW

MTD MOUNTED

MTG MOUNTING

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NS NONSHRINK

NTS NOT TO SCALE

NWC NORMAL WEIGHT CONCRETE

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER/OVERFLOW DRAIN

OFF OFFICE

OPNG OPENING

OPP OPPOSITE

OZ OUNCE

PART PARTITION

PC PIECE

PCC PRECAST CONCRETE

PCPL PORTLAND CEMENT PLASTER

PDWR PAPER TOWEL DISPENSER & WASTE RECEPTACLE

PH PHILLIPS HEAD/PHASE

PL PLASTIC LAMINATE/PLATE/PROPERTY LINE

PLAS PLASTER

PLBG PLUMBING

PLYWD PLYWOOD

PM PROTECTED METAL

PNL PANEL

PNLG PANELING

POL POLISHED

PR PAIR

PRE FAB PREFABRICATED

PRE FIN PRE-FINISHED

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT POINT/PAINT

PTM PAINT TO MATCH

PVC POLYVINYL CHLORIDE

PWC PANELIZED WOOD CEILING

QT QUARRY TILE

QTY QUANTITY

RAD RADIUS

RAH ROOFTOP AIR HANDLING UNIT

RB RUBBER BASE

RC REINFORCED CONCRETE

RCP RADIANT CEILING PANEL

/ REFLECTED CEILING PLAN

RD ROOF DRAIN

REC RECESSED

REF REFERENCE

REINF REINFORCING

REL RELOCATE

REM REMAINDER

REQD REQUIRED

RES RESILIENT

RET RETURN

RI ROUGH IN

RM ROOM

RO ROUGH OPENING

RT RUBBER TILE

RUB RUBBER

SAT STANDARD AGGREGATE TOPPING

SAWM SELF ADHEARED WATERPROOF MEMBRANE

SB SOIL BEARING

SC SEAMLESS COATING

SCF SPECIAL CONCRETE FINISH

SCHD SCHEDULE

SD SOAP DISPENSER

SE SHELF EDGE

SECT SECTION

SF SAND FLOAT

SG SUPPLY AIR GRILLE

SGL SINGLE

SH SHELF

SHD SHOWER DOOR

SHT SHEET

SIM SIMILAR

SJ STEEL JOIST

SLV SHORT LEG VERTICAL

SM SMOOTH

SND SANITARY NAPKIN DISPENSER

SNV SANITARY NAPKIN VENDER

SOG SLAB ON GRADE

SPEC SPECIFICATION

SPR SPRINKLER

SQ SQUARE

SR SHOWER ROD

SS STAINLESS STEEL

SSCP SECURITY SCREENING CHECKPOINT

ST STREET

STD STANDARD

STL STEEL

STO STORAGE

STRU STRUCTURAL/STRUCTURE

SUSP SUSPENDED

SV SHEET VINYL

SYM SYMMETRICAL

T & B TOP AND BOTTOM

TB TACKBOARD/TOWEL BAR

TBR TO BE REMOVED

TCP THIN COAT PLASTER

TD TOWEL DISPENSER

TDW TOWEL DISPENSER AND WASTE

TEMP TEMPERATURE/TEMPERED

TER TERRAZZO

TEX TEXTURE

TFC TROWELED FLOOR COVERING

T & G TONGUE AND GROOVE

THK THICK

TI TENANT IMPROVEMENT

TOB TOP OF BEAM

TOC TOP OF CURB/TOP OF CONCRETE

TOD TOP OF DECK/TOP OF DUCT ELEVATION

TOF TOP OF FOOTING

TOJ TOP OF JOIST

TOP TOP OF PIPE ELEVATION

TOS TOP OF SLAB/TOP OF STEEL

TOW TOP OF WALL

TPG TOPPING

TPH TOILET PAPER HOLDER

TRAN TRANSOM

TRANS TRANSVERSE

TS TUBE STEEL

TWS THREADED WELDED STUD

TYP TYPICAL

UG UNDERGROUND

UNO UNLESS NOTED OTHERWISE

UR URINAL

V VINYL

VB VINYL BASE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VOL VOLUME

VWC VINYL WALL COVERING

W WIDE FLANGE STEEL BEAM

W/ WITH

WAF WELDED ANGLE FRAME

WC WATER CLOSET

WD WOOD

WDW WINDOW

WF WIDE FLANGE

WG WIRE GLASS

W/O WITHOUT

WP WEATHERPROOF

WPFG WATERPROOFING

WR WASTE RECEPTACLE

WSCT WAINSCOT

WSTP WEATHERSTRIP

WTR WATER

WWF WELDED WIRE FABRIC

X EXISTING

ABBREVIATIONS ABOVE ARE FOR ARCHITECTURAL SHEETS ONLY.

ABBREVIATIONS

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com

/3

/2

:4

:0

P

M

.0

-A

-R d e ta c h e d .r v t

D U

R A

N G

O -L

A P

L A

T A

C O

U N

T Y

A

IR

P O

R T

A ir p o rt

R d

D u ra n g o

C

O

D R

O T

E R

M

IN

A L E

X P

A N

S

IO

N A

N D

M O

D E

R N

IZ

A

T

IO

N

P H

A S

E

B

A-001

NOTES & SYMBOLS

0419000-182253.05

MW, NC, MS

JC, TD

04/08/24

NC, MW

09/06/24 CONFORMED SET

DURANGO-LA PLATA COUNTY AIRPORTDURANGO-LA PLATA COUNTY AIRPORT

CONCESSIONS RFP - EXHIBITS

DRO PHASE 1B CONCESSIONS RFP

DRO PHASE 1B - OVERALL FLOOR PLAN

ARCHITECTURE

A-001 - NOTES & SYMBOLS

A-101C - 1ST FLOOR PLAN - AREA C

A-101E - 1ST FLOOR PLAN - AREA E

A-101F - 1ST FLOOR PLAN - AREA F

A-121C - 1ST FLOOR RCP - AREA C

A-121E - 1ST FLOOR RCP - AREA E

A-121F - 1ST FLOOR RCP - AREA F

A-401 - ENLARGED PLANS AND ELEVATIONS

A-402 - ENLARGED PLANS AND ELEVATIONS

A-506 - INTERIOR CEILING DETAILS

A-611 - WINDOW TYPE AND ELEVATIONS

INTERIORS

I-001 - NOTES & SYMBOLS

I-101C - FIRST FLOOR FINISH PLAN - AREA C

I-101E - FIRST FLOOR FINISH PLAN - AREA E

I-101F - FIRST FLOOR FINISH PLAN - AREA F

I-201 - INTERIOR BUILDING ELEVATIONS

I-203 - INTERIOR BUILDING ELEVATIONS

I-424 - ENLARGED CASEWORK PLANS, ELEVATIONS & DETAILS

I-425 - ENLARGED CASEWORK PLANS, ELEVATIONS & DETAILS

I-426 - ENLARGED CASEWORK PLANS, ELEVATIONS & DETAILS

I-601 - SCHEDULES

FIRE PROTECTION

F-001 - SYMBOLS, ABBREVIATIONS, NOTES AND DETAILS

F-002 - SYMBOLS, ABBREVIATIONS, NOTES AND DETAILS

FA-103 - FIRE ALARM FIRST FLOOR - AREA C

FA-105 - FIRE ALARM FIRST FLOOR - AREA E

FA-106 - FIRE ALARM FIRST FLOOR - AREA F

PLUMBING

P-001 - NOTES, SYMBOLS AND ABBREVIATIONS

P-100C - UNDERGROUND DRAIN AND VENT PLAN - AREA C

P-100E - UNDERGROUND DRAIN AND VENT PLAN - AREA E

P-100F - UNDERGROUND DRAIN AND VENT PLAN - AREA F

P-101C - FIRST FLOOR DRAIN AND VENT PLAN - AREA C

P-101E - FIRST FLOOR DRAIN AND VENT PLAN - AREA E

P-101F - FIRST FLOOR DRAIN AND VENT PLAN - AREA F

P-131C - FIRST FLOOR SUPPLY PLAN - AREA C

P-131E - FIRST FLOOR SUPPLY PLAN - AREA E

P-131F - FIRST FLOOR SUPPLY PLAN - AREA F

P-601 - PLUMBING SCHEDULES

MECHANICAL

M-001 - NOTES, SYMBOLS AND ABBREVIATIONS

M-101C - FIRST FLOOR HVAC PLAN - AREA C

M-101E - FIRST FLOOR HVAC PLAN - AREA E

M-101F - FIRST FLOOR HVAC PLAN - AREA F

ELECTRICAL

E-001 - NOTES, SYMBOLS & ABBREVIATIONS

E-101C - FIRST FLOOR POWER PLAN - AREA C

E-101E - FIRST FLOOR POWER PLAN - AREA E

E-101F - FIRST FLOOR POWER PLAN - AREA F

E-121C - FIRST FLOOR LIGHTING PLAN - AREA C

E-121E - FIRST FLOOR LIGHTING PLAN - AREA E

E-121F - FIRST FLOOR LIGHTING PLAN - AREA F

E-401 - ENLARGED PLANS, ELEVATIONS, & SECTIONS

E-601 - POWER SCHEDULES

E-621 - LIGHTING SCHEDULES

TECHNOLOGY

T-001 - NOTES, SYMBOLS & ABBREVIATIONS

T-101C - FIRST FLOOR COMMUNICATIONS PLAN - AREA C

T-101E - FIRST FLOOR COMMUNICATIONS PLAN - AREA E

T-101F - FIRST FLOOR COMMUNICATIONS PLAN - AREA F

APPENDIX 1 - CONCEPTUAL CONCESSIONS LAYOUTS

FS1.0 - EQUIPMENT PLAN

FS1.1 - EQUIPMENT PLAN

FS1.2 - EQUIPMENT PLAN

FS2.0 - EQUIPMENT ELEVATIONS

FS2.1 - EQUIPMENT ELEVATIONS

FS3.0 - ELECTRICAL PLAN

FS3.1 - ELECTRICAL PLAN

FS4.0 - PLUMBING PLAN

FS4.1 - PLUMBING PLAN

FS5.0 - DETAILS

APPENDIX 2 - CONCEPTUAL RENDERINGS

CONCEPTUAL RENDERING - AIRSIDE 1

CONCEPTUAL RENDERING - AIRSIDE 2

DRO DRO TERMINAL EXPANSION AND MODERNIZATION - PHASE 1B

04/28/25

DURANGO-LA PLATA COUNTY AIRPORT

CONCESSIONS RFP

SHEET INDEX

F.E.C

F.E.

WELDED ANGLE FRAME

WATER CLOSET

WOOD

WINDOW

WIDE FLANGE

DRO PHASE 1B CONCESSIONS RFP

DRO PHASE 1B - OVERALL FLOOR PLAN

EXHIBITS

LANDSIDE FOOD & BEVERAGE

AIRSIDE BAR / CAFE

AIRSIDE RETAIL

AIRSIDE FOOD & BEVERAGE - SOUTH

F.E.

G A

TE

S 1, 2 &

G A

TE

G A

TE

G A

TE

7 G A

TE

NORTH

CONCOURSESOUTH

CONCOURSE

VESTIBULE

VESTIBULE

WAIT

BAG

CLAIM

EXIT

LANE

TSA

TRAINING

TSA

STORAGE

BREAK ROOM

OFFICE

PVT

SCREEN

AIRSIDE

CONCOURSE

- NORTH

DEPARTURE

LOUNGE

ART

DEPARTURE

LOUNGE

DEPARTURE

LOUNGE

DEPARTURE

LOUNGE

CORRIDOR

OUTDOOR

PATIO

MEN

WOMEN

BAG

MAKEUP

PASSENGER

SCREENING

RETAIL

PASS

SCREEN

QUEUE

CAFE/GIFT

KITCHEN

WOMENMEN

VEST

CUSTODIAL

OFFICE

JAN

ELECT

MECHANICAL

ELECT

ELECT

UTILITIES

AIRPORT

STORAGE

COMM

TSA LAN

HALLWAY

CIRC

JAN.

CLO.

ELEV.

MACH.

TELE/COMM

AIRLINE

BREAK

ROOM

BAG

STORAGE

ATO

OFFICE

ATO

OFFICE

OFFICEOFFICEOFFICETSA

OFFICE

BAGGAGE

SCREENING

ATO

OFFICE

ATO

OFFICE

ATO

OFFICE

AIRLINE

IT

OFFICEOFFICEOFFICEOFFICEOFFICEOFFICE

OFFICEOFFICEOFFICEOFFICEOFFICE

TICKETING

FAMILYFAMILYLACT.

CORRIDOR

VESTIBULE

WAITING

VEST

VEST.

VEST.

VEST. VEST

MEN

WOMEN

CORRIDOR

CONCESS

STOR

BAG

STORAGE

AIRPORT

STORAGE OFFICE

WOMENMEN

AIRSIDE

CONCOURSE

- SOUTH

VESTIBULE

FAMILY

RR

FAMILY

RR

FIRE

SPRINKLER

RISER

ROOM

JAN

KITCHEN

CAFE

CENTRAL

CONCOURSE

STORAGE

BAG

STORAGE

DEPARTURE

LOUNGE

AIRLINE IT

CONCESSIONS

BOH

CONCESSIONS

STORAGE

AIRPORT

ADMINISTRATION

DRO DRO TERMINAL EXPANSION AND MODERNIZATION - PHASE 1B

04/28/25

DURANGO-LA PLATA COUNTY AIRPORT

CONCESSIONS RFP

LANDSIDE

FOOD & BEVERAGE

AIRSIDE RETAIL

AIRSIDE BAR/CAFE

AIRSIDE

FOOD & BEVERAGE

- SOUTH

LANDSIDE FOOD & BEVERAGE

AIRPORT PROVIDED

CONCESSIONAIRE PROVIDED

- Lighting - See E-121C

- Plumbing connections (locations TBD) for front and back of house. See P-100C for list of estimated plumbing supply and sanitary connection needs.

- Grease Interceptor - location TBD

- Electrical power connections - See E-101C, 5/E-401

- Interior Finishes

- Bar Millwork - See I-424

- Tiled wall behind bar - See I-424

- Wood Baffle Ceiling - See A-121C, A-506

- Existing Kitchen Hood Roof Penetration - See M-101C

- Lockable Sliding Security Grille with storage hatch

- Sealed concrete floor - see I-101C

- All kitchen equipment and fixtures including sinks

- Kitchen hood, ductwork, exhaust fan and fire suppression system for hood

- All seating and tables

- Any retail shelving and displays

- Signage

- Storage

- Floor finishes, selected and installed by tenant

1-168

CAFE/GIFT

1-168B

KITCHEN

1-168A

CONCESSIONS

BOH

1-168A.1

CONCESSIONS

STORAGE

592 sf

236 sf 121 sf

829 sf

'-1

19'-6" 42'-9"

'-7

8'

-4

14'-4"27'-9"

CONCESSIONAIRE PROVIDED

AIRSIDE BAR / CAFE

1-196

KITCHEN

1-197

VEST

1-211

CAFE

225 sf

831 sf

25'-8"

'-9

12'-8"

'-2

- Lighting - See E-121F

- Plumbing connections (locations TBD) for front and back of house. See P-100F for list of estimated plumbing supply and sanitary connection needs.

- Grease Interceptor - Location TBD

- Electrical power connections - See E-101F

- Roof Penetration for kitchen hood

- Interior Finishes

- Bar Millwork - See I-425

- Tiled wall behind bar with build in lights - See I-425

- Wood Baffle Ceiling - See A-121F, A-506

- LVT flooring in bar/seating area - see I-101F

- Sealed-concrete floor in all other areas - see I-101F

- All kitchen equipment and fixtures including sinks.

- All seating and tables

- Any retail shelving and displays

- Signage

- Storage

- Kitchen hood, ductwork, exhaust fan and fire suppression system for hood, if desired

- Additional floor finishes, selected and installed by tenant

AIRPORT PROVIDED CONCESSIONAIRE PROVIDED

AIRSIDE RETAIL

- Lighting - See E-121F

- Electrical power connections - See E-101F

- Lockable Sliding Security Grille with storage hatch

- Sealed-concrete floor - see I-101F

- Retail counter

- Retail shelving, storage and displays

- Signage

- Finished floor - selected and installed by tenant

AY

1-203

OFFICE

1-214

STOR

1-204

PVT SCREEN

1-213

RETAIL

475 sf

194 sf

13'-1"

'-9

'-1 1"

22'-2"

8' -1

AIRSIDE FOOD & BEVERAGE - SOUTH

CONCESSIONAIRE PROVIDED

SA3

SA3

1-136

CONCESS

1-135

CONCESS4.1474.147

1-135

428 sf

30'-0"

'-1

- Lighting - See E-121E

- Electrical power connections - See E-101E, 3/E-401

- Plumbing connections (locations TBD) See P-100E for list of estimated plumbing supply and sanitary connection needs.

- Lockable Sliding Security Grille

- Sealed-concrete floor - see I-101E

- All kitchen equipment and fixtures including sinks

- Retail counter and millwork

- shelving, storage and displays

- Signage

- Floor finishes, selected and installed by tenant

LEGEND - PLAN SYMBOLS

ROOM NAME AND NUMBER

WALL TYPE

IDENTIFICATION

KEYED NOTE IDENTIFICATION

WINDOW IDENTIFICATION

DOOR IDENTIFICATION

FLOOR DRAIN

4.XXX

DETAIL SYMBOL

EXTERIOR ELEVATION

SYMBOL

WALL SECTION SYMBOL

INTERIOR ELEVATION

SYMBOL

BUILDING SECTION SYMBOL

FD

FIRE EXTINGUISHER - SURFACE MOUNT

FIRE EXTINGUISHER CABINET AND FIRE

EXTINGUISHER - SEMI-RECESSED

1 HOUR FIRE RATED WALL

ROOM NAME

A-211

A-201

ENLARGED PLAN

SYMBOL

A

XXX

X' - X"

W?

A100

A100

A-101

SIM

A-101

SIM

XXX

X

A-101

A-101

A-101

A-101

F.E.C.

F.E.

EXISTING GRID LINES

NEW GRID LINES

LEVEL OR SPOT ELEVATIONS

ACP-X

10'-10" CEILING HEIGHT & FINISH

MATCHLINE

HATCH SYMBOLS

EARTHWORK

GRAVEL

PLASTER,

SAND, GROUT

CONCRETE

CONCRETE

MASONRY

CLAY

MASONRY

PRECAST

CONCRETE

METAL

PLYWOOD

FINISH LUMBER

WOOD STUDS,

BLOCKING

STEEL STUDS

GYPSUM

WALLBOARD

ACOUSTICAL

TILE

BATT

INSULATION

RIGID

INSULATION

ANGLE

@ AT

AB ANCHOR BOLT

AC ACOUSTIC

ACC ACCESS

ACT ACOUSTIC CEILING TILE

ACP ACOUSTIC CEILING PANEL

AD AREA DRAIN

ADD ADDITIONAL

ADJ ADJUSTABLE

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

AL ALUMINUM

ALT ALTERNATE

AP ACCESS PANEL

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASPH ASPHALT

BB BOND BEAM

BD BOARD

BF BOTH FACES

BFC BELOW FINISH CEILING

BG BUMPER GUARD

BIT BITUMINOUS

BLDG BUILDING

BLKG BLOCKING

BLKT BLANKET

BM BEAM/BENCH MARK

BLK BLOCK

BOT BOTTOM

BRG BEARING

BRKR BREAKER

BRK BRICK

BRKT BRACKET

BS BACK SPLASH

BSMT BASEMENT

BTWN BETWEEN

CHN CHANNEL

CAB CABINET

CER CERAMIC

CFCI CONTRACTOR FURNISHED,

CONTRATOR INSTALLED

CG CORNER GUARD

CH COAT HOOK

CIP CAST IN PLACE

CJ CONTROL JOINT/CONSTRUCTION

JOINT

CLG CEILING

CLO CLOSET/CLOSURE

CLR CLEAR

COL COLUMN

COMB COMBINATION

CMU CONCRETE MASONRY UNIT

CONC CONCRETE

CONF CONFERENCE

CONN CONNECTION/CONNECT

CONST CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACTOR

CORR CORRIDOR

CPT CARPET

CR COAT RACK/CURTAIN ROD

CSG CASING

CT CERAMIC TILE

CTR CENTER/COUNTER

CTSK COUNTERSUNK

CUH CABINET UNIT HEATER

CW COLD WATER

DAS DISTRIBUTED ANTENNA SYSTEM

D DEPTH

DBL DOUBLE

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DIR DIRECTION

DIV DIVISION

DM DEMOUNTABLE PARTITION

DN DOWN

DO DITTO

DR DOOR

DRWR DRAWER

DS DOWNSPOUT

DWG DRAWING

DWL DOWEL

DWS DEFORMED WELDED STUD

EA EACH

EC ELECTRICAL CONTRACTOR

EF EACH FACE

EH ELECTRICAL HEATER/EXHAUST

HOOD

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR/ELEVATION

EMBED EMBEDDED

EMER EMERGENCY

ENT ENTRANCE

EQ EQUAL

EQUIP EQUIPMENT

ES EMERGENCY SHOWER

ESR ELASTOMERIC SHEET ROOFING

ETR EXISTING TO REMAIN

EVC ELASTIC VINYL COATING

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXC EXCAVATE

EXP EXPANSION

EXPD EXPOSED

EXPF EXPLOSION PROOF

EXT EXTERIOR

FA FIELD ADJUSTABLE

FV FIELD VERIFY

FD FLOOR DRAIN

FDN FOUNDATION

FFE FINISHES, FURNITURE, EQUIPMENT

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FHC FIRE HOSE CABINET

FIN FINISH

FIX FIXTURE

FLEX FLEXIBLE

FLR FLOOR

FLRG FLOORING

FOM FACE OF MASONRY

FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR

FP FIREPROOF/FIRE PROTECTION

FR FIRE RETARDANT

FRP FIBERGLASS REINFORCED PANEL

FS FULL SIZE/FULL SCALE

FT FEET

FTG FOOTING

FURG FURRING

GA GAUGE

GAL GALLON

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GEN GENERAL

GFCI GOVERNMENT FURNISHED, CONTRACTOR INSTALLED

GFGI GOVERNMENT FURNISHED, GOVERNMENT INSTALLED

GFRC GLASS FIBER REINFORCED CONCRETE

GFRG GLASS FIBER REINFORCED GYPSUM

GL GLASS

GMU GLAZED MASONRY UNIT

GWB GYPSUM WALL BOARD

GYP GYPSUM

H HEIGHT

HDBD HARDBOARD

HDCP HANDICAPPED

HDWD HARDWOOD

HDWE HARDWARE

HK HOOK

HM HOLLOW METAL

HP HIGH POINT

HR HANDRAIL

HT HEIGHT

HVAC HEATING VENTILATION AND AIR CONDITIONING

HWS HEAD WELDED STUDS

ID INSIDE DIAMETER

IMP INSULATED METAL PANEL

IN INCHES

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

IPW INSULATED PLENUM WALL

IRF INSULATED ROOF FILL

JAN JANITOR

JS JANITOR SINK

JST JOIST

JT JOINT

KD KNOCKED DOWN

KO KNOCK-OUT / KNEE OPENING

L LENGTH

LAB LABORATORY

LAM LAMINATED

LB POUND

LBS POUNDS

LD LINEAR DIFFUSER

LDG LANDING

LF LINEAR FOOT

LG LONG

LGT LIGHT

LKR LOCKER

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LONG LONGITUDINAL

LP LOW POINT

LPS LIGHTNING PROTECTION SYSTEM

LSH LONG SLOTTED HOLE

LTG LIGHTING

LVR LOUVER

LWC LIGHTWEIGHT CONCRETE

MACH MACHINE

MAN MANUAL

MAR MARBLE

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MB MACHINE BOLT

MBW MASONRY BEARING WALL

MC MECHANICAL CONTRACTOR

MDO MEDIUM DENSITY OVERLAY

MECH MECHANICAL

MEMB MEMBRANE

MET METAL

MEZZ MEZZANINE

MFR MANUFACTURER

MIN MINIMUM

MIR MIRROR

MISC MISCELLANEOUS

MK MARK

ML METAL LATH

MLDG MOLDING

MO MASONRY OPENING

MP METAL PARTITION

MS MACHINE SCREW

MTD MOUNTED

MTG MOUNTING

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NS NONSHRINK

NTS NOT TO SCALE

NWC NORMAL WEIGHT CONCRETE

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER/OVERFLOW DRAIN

OFF OFFICE

OPNG OPENING

OPP OPPOSITE

OZ OUNCE

PART PARTITION

PC PIECE

PCC PRECAST CONCRETE

PCPL PORTLAND CEMENT PLASTER

PDWR PAPER TOWEL DISPENSER & WASTE RECEPTACLE

PH PHILLIPS HEAD/PHASE

PL PLASTIC LAMINATE/PLATE/PROPERTY LINE

PLAS PLASTER

PLBG PLUMBING

PLYWD PLYWOOD

PM PROTECTED METAL

PNL PANEL

PNLG PANELING

POL POLISHED

PR PAIR

PRE FAB PREFABRICATED

PRE FIN PRE-FINISHED

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT POINT/PAINT

PTM PAINT TO MATCH

PVC POLYVINYL CHLORIDE

PWC PANELIZED WOOD CEILING

QT QUARRY TILE

QTY QUANTITY

RAD RADIUS

RAH ROOFTOP AIR HANDLING UNIT

RB RUBBER BASE

RC REINFORCED CONCRETE

RCP RADIANT CEILING PANEL

/ REFLECTED CEILING PLAN

RD ROOF DRAIN

REC RECESSED

REF REFERENCE

REINF REINFORCING

REL RELOCATE

REM REMAINDER

REQD REQUIRED

RES RESILIENT

RET RETURN

RI ROUGH IN

RM ROOM

RO ROUGH OPENING

RT RUBBER TILE

RUB RUBBER

SAT STANDARD AGGREGATE TOPPING

SAWM SELF ADHEARED WATERPROOF MEMBRANE

SB SOIL BEARING

SC SEAMLESS COATING

SCF SPECIAL CONCRETE FINISH

SCHD SCHEDULE

SD SOAP DISPENSER

SE SHELF EDGE

SECT SECTION

SF SAND FLOAT

SG SUPPLY AIR GRILLE

SGL SINGLE

SH SHELF

SHD SHOWER DOOR

SHT SHEET

SIM SIMILAR

SJ STEEL JOIST

SLV SHORT LEG VERTICAL

SM SMOOTH

SND SANITARY NAPKIN DISPENSER

SNV SANITARY NAPKIN VENDER

SOG SLAB ON GRADE

SPEC SPECIFICATION

SPR SPRINKLER

SQ SQUARE

SR SHOWER ROD

SS STAINLESS STEEL

SSCP SECURITY SCREENING CHECKPOINT

ST STREET

STD STANDARD

STL STEEL

STO STORAGE

STRU STRUCTURAL/STRUCTURE

SUSP SUSPENDED

SV SHEET VINYL

SYM SYMMETRICAL

T & B TOP AND BOTTOM

TB TACKBOARD/TOWEL BAR

TBR TO BE REMOVED

TCP THIN COAT PLASTER

TD TOWEL DISPENSER

TDW TOWEL DISPENSER AND WASTE

TEMP TEMPERATURE/TEMPERED

TER TERRAZZO

TEX TEXTURE

TFC TROWELED FLOOR COVERING

T & G TONGUE AND GROOVE

THK THICK

TI TENANT IMPROVEMENT

TOB TOP OF BEAM

TOC TOP OF CURB/TOP OF CONCRETE

TOD TOP OF DECK/TOP OF DUCT ELEVATION

TOF TOP OF FOOTING

TOJ TOP OF JOIST

TOP TOP OF PIPE ELEVATION

TOS TOP OF SLAB/TOP OF STEEL

TOW TOP OF WALL

TPG TOPPING

TPH TOILET PAPER HOLDER

TRAN TRANSOM

TRANS TRANSVERSE

TS TUBE STEEL

TWS THREADED WELDED STUD

TYP TYPICAL

UG UNDERGROUND

UNO UNLESS NOTED OTHERWISE

UR URINAL

V VINYL

VB VINYL BASE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VOL VOLUME

VWC VINYL WALL COVERING

W WIDE FLANGE STEEL BEAM

W/ WITH

WAF WELDED ANGLE FRAME

WC WATER CLOSET

WD WOOD

WDW WINDOW

WF WIDE FLANGE

WG WIRE GLASS

W/O WITHOUT

WP WEATHERPROOF

WPFG WATERPROOFING

WR WASTE RECEPTACLE

WSCT WAINSCOT

WSTP WEATHERSTRIP

WTR WATER

WWF WELDED WIRE FABRIC

X EXISTING

ABBREVIATIONS ABOVE ARE FOR ARCHITECTURAL SHEETS ONLY.

ABBREVIATIONS

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com

/3

/2

:4

:0

P

M

.0

-A

-R d e ta c h e d .r v t

D U

R A

N G

O -L

A P

L A

T A

C O

U N

T Y

A

IR

P O

R T

A ir p o rt

R d

D u ra n g o

C

O

D R

O T

E R

M

IN

A L E

X P

A N

S

IO

N A

N D

M O

D E

R N

IZ

A

T

IO

N

P H

A S

E

B

A-001

NOTES & SYMBOLS

0419000-182253.05

MW, NC, MS

JC, TD

04/08/24

NC, MW

09/06/24 CONFORMED SET

NOT FOR CONSTRUCTION

05/01/25 CONCESSIONS RFP

FLOOR PLAN GENERAL NOTES:

1. SITE DATUM OF FINISHED FIRST FLOOR INDICATED ON SITE PLAN = 100'-0" ON

ARCHITECTURAL DRAWINGS.

2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE

ATTENTION OF THE ARCHITECT/ENGINEER FOR FINAL DECISION.

3. ALL INTERIOR DIMENSIONS ARE FROM FINISH FACE OF WALLS (I.E. GYPSUM

WALLBOARD OR CMU), UNLESS NOTED OTHERWISE. FINISHES MAY EFFECT

ACTUAL DISTANCES, COORDINATE WITH INTERIORS.

4. FLOOR LEVEL ELEVATIONS ARE TO THE TOP OF CONCRETE, UNLESS NOTED

OTHERWISE.

5. REFERENCE SHEET G-011 G-021 AND G-022 FOR ALL CODE, FIRE RATING, AND

SEPARATION REQUIREMENTS.

6. GENERAL CONTRACTOR SHALL PATCH AND REPAIR EXISTING CONSTRUCTION

(WALLS, DOORS, CEILINGS, FLOORS, ETC.) AS REQUIRED FROM DEMOLITION

OR CONSTRUCTION TO ALLOW FOR THE PREP WORK OF NEW OR

COMPLETION OF EXISTING FINISHES. REPAIRS OR REPLACEMENTS MUST BE

DURABLE, SEAMLESS, AND MATCH THE EXISTING MATERIAL.

7. GENERAL CONTRACTOR SHALL PATCH ALL FLOOR AND WALL PENETRATIONS

CAUSED BY DEMOLITION OF MECHANICAL, ELECTRICAL, TECHNOLOGY, AND

PLUMBING, INCLUDING BUT NOT LIMITED TO PIPING AND CONDUIT RUNS, IN A

MANNER THAT IS CONSISTENT WITH THE EXISTING FLOOR AND WALL

CONSTRUCTION AND FINISH. ALL PENETRATIONS SHALL MEET REQUIRED FIRE

RATINGS.

8. COORDINATE THE INSTALLATION OF ALL OWNER-SUPPLIED EQUIPMENT.

REFERENCE PLANS, SPECS, AND INTERIOR ELEVATIONS FOR SPECIFIC

EQUIPMENT AND ITS INSTALLATION REQUIREMENTS.

9. GENERAL CONTRACTOR SHALL PROVIDE BLOCKING, STIFFENERS, BRACINGS,

BACKING PLATES, SUPPORTING BRACKETS, AND NECESSARY SELECTIVE

DEMOLITION REQUIRED FOR THE PROPER INSTALLATION OF ALL CASEWORK,

TOILET ROOM ACCESSORIES, TOILET PARTITIONS AND MISCELLANEOUS

EQUIPMENT.

10. EXISTING AND INFILL CONCRETE SUB-FLOOR SHALL BE MADE LEVEL, AND IN

SOUND CONDITION AS REQUIRED FOR THE INSTALLATION OF FINAL FLOOR

FINISHES, TYPICAL. PROVIDE ARDEX OR EQUAL LEVELING CONCRETE IF

NECESSARY TO PROVIDE A SMOOTH WALKABLE AREA.

11. ALL RECESSED CABINETS, PANELS, BOXES, ETC. LOCATED IN FIRE-RATED

PARTITIONS SHALL BE INSTALLED IN A MANNER WHICH MAINTAINS THE FIRE

RATED CONSTRUCTION.

12. SEE ENLARGED PLANS FOR NOTES, DIMENSIONS, AND WALL TYPES WITHIN

THE DETAIL CALLOUT BOUNDARIES.

13. REFERENCE SHEET A-002 FOR INTERIOR PARTITION TYPES. INTERIOR

PARTITION TAGS NOTED ENCOMPASS THE ENTIRE LENGTH OF WALL SHOWN

TO CORNERS OF ROOM, OVER AND AROUND DOORWAYS SHOWN.

14. REFERENCE SHEET I-100'S FOR FINISH PLANS.

15. REFERENCE SHEET A-800 SERIES SHEETS FOR SIGNAGE LAYOUTS AND

COORDINATION REQUIREMENTS.

16. REFERENCE SHEET I-700 SERIES SHEETS FOR FURNITURE AND EQUIPMENT

LAYOUTS AND COORDINATION REQUIREMENTS.

LEGEND - PLAN SYMBOLS

ROOM NAME AND NUMBER

WALL TYPE

IDENTIFICATION

KEYED NOTE IDENTIFICATION

WINDOW IDENTIFICATION

DOOR IDENTIFICATION

FLOOR DRAIN

4.XXX

DETAIL SYMBOL

EXTERIOR ELEVATION

SYMBOL

WALL SECTION SYMBOL

INTERIOR ELEVATION

SYMBOL

BUILDING SECTION SYMBOL

FD

FIRE EXTINGUISHER - SURFACE MOUNT

FIRE EXTINGUISHER CABINET AND FIRE

EXTINGUISHER - SEMI-RECESSED

1 HOUR FIRE RATED WALL

ROOM NAME

A-211

A-201

ENLARGED PLAN

SYMBOL

A

XXX

X' - X"

W?

A100

A100

A-101

SIM

A-101

SIM

XXX

X

A-101

A-101

A-101

A-101

F.E.C.

F.E.

EXISTING GRID LINES

NEW GRID LINES

LEVEL OR SPOT ELEVATIONS

ACP-X

10'-10" CEILING HEIGHT & FINISH

MATCHLINE

AA

BB

CC

DD

E

B.3B.3

A-301

A-301

A-302

A-312

A.1

B.2

C.7

D.3

D.3

D.7

E.4

2.8

2.8

MATCHLINE

SEE 1 / A-101E

M A

T C

H L

IN

E

S E

E

A

-1 F

M A

T C

H L

IN

E

S E

E

A

-1 G

M A

T C

H L

IN

E

S E

E

A

-1 G

MATCHLINE

SEE 1 / A-101F

1-228

1-101

VESTIBULE

1-167

CENTRAL

CONCOURSE

1-170

VESTIBULE

1-180

OFFICE

1-179

COUNTER

1-178

OFFICE

1-177

COUNTER

1-176

OFFICE

1-175

COUNTER

1-174

OFFICE

1-173

COUNTER

1-172

OFFICE

1-171

COUNTER

1-168

CAFE/GIFT

1-168B

KITCHEN

1-164

CUSTODIAL

OFFICE 1-158

MECHANICAL

1-163

WOMEN

1-157

ELECT

1-156

ELECT

1-160

MEN

1-160A

VEST

1-161

JAN

1-163A

VEST

S1-1

STAIRWAY

1-102

CIRC

1-229

UTILITIES

1-226

TSA

STORAGE

1-224A

TSA TRAINING

1-202

OFFICE

1-228

AIRPORT

STORAGE

1-169

PASS

SCREEN

QUEUE

MATCHLINE

SEE 1 / A-101E

MATCHLINE

SEE 1 / A-101B

M A

T C

H L

IN

E

S E

E

A

-1 B

A-302

SA6

1-229

1-220.1

1-164

4.125

A-501

1-166

WOMEN

1-165

MEN

1-166A

VEST

1-165A

VEST

1-165A1

JAN

C-6

CHASE

A-403

EDGE OF CANOPY ABOVE

A-508

A-508

A-402

A-402

FC1

FC1

FC1

FC1

A-401

1-168A

CONCESSIONS

BOH

1-168A.1

CONCESSIONS

STORAGE

4.142

4'-8"

A-508

A-301

KEY PLAN

A

B C

F

ED

G

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com

/3

/2

:4

:0

P

M

.0

-A

-R d e ta c h e d .r v t

D U

R A

N G

O -L

A P

L A

T A

C O

U N

T Y

A

IR

P O

R T

A ir p o rt

R d

D u ra n g o

C

O

D R

O T

E R

M

IN

A L E

X P

A N

S

IO

N A

N D

M O

D E

R N

IZ

A

T

IO

N

P H

A S

E

B

A-101C

1ST FLOOR PLAN -

AREA C

0419000-182253.05

MW, NC, MS

JC, TD

04/08/24

NC, MW

KEYED NOTES

4.125 SLIDING SECURITY GRILLE

4.142 LIGHTNING PROTECTION SYSTEM CONDUCTOR LOCATION; INTERIOR TO

BUILDING; INCLUDE ROOF PENETRATION AND CONNECTION TO GROUND

ROD LOCATION; REFER TO ELECTRICAL. DEMO CONCRETE AND WALLS AS

NEEDED; PAINT PATCH AND REPAIR.

1/8" = 1'-0"1

FIRST FLOOR PLAN - AREA C

09/06/24 CONFORMED SET

LANDSIDE

FOOD & BEV

NOT FOR CONSTRUCTION

05/01/25 CONCESSIONS RFP

592 sf

236 sf 121 sf

829 sf

'-1

19'-6" 42'-9"

'-7

8'

-4

14'-4"27'-9"

FLOOR PLAN GENERAL NOTES:

1. SITE DATUM OF FINISHED FIRST FLOOR INDICATED ON SITE PLAN = 100'-0" ON

ARCHITECTURAL DRAWINGS.

2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE

ATTENTION OF THE ARCHITECT/ENGINEER FOR FINAL DECISION.

3. ALL INTERIOR DIMENSIONS ARE FROM FINISH FACE OF WALLS (I.E. GYPSUM

WALLBOARD OR CMU), UNLESS NOTED OTHERWISE. FINISHES MAY EFFECT

ACTUAL DISTANCES, COORDINATE WITH INTERIORS.

4. FLOOR LEVEL ELEVATIONS ARE TO THE TOP OF CONCRETE, UNLESS NOTED

OTHERWISE.

5. REFERENCE SHEET G-011 G-021 AND G-022 FOR ALL CODE, FIRE RATING, AND

SEPARATION REQUIREMENTS.

6. GENERAL CONTRACTOR SHALL PATCH AND REPAIR EXISTING CONSTRUCTION

(WALLS, DOORS, CEILINGS, FLOORS, ETC.) AS REQUIRED FROM DEMOLITION

OR CONSTRUCTION TO ALLOW FOR THE PREP WORK OF NEW OR

COMPLETION OF EXISTING FINISHES. REPAIRS OR REPLACEMENTS MUST BE

DURABLE, SEAMLESS, AND MATCH THE EXISTING MATERIAL.

7. GENERAL CONTRACTOR SHALL PATCH ALL FLOOR AND WALL PENETRATIONS

CAUSED BY DEMOLITION OF MECHANICAL, ELECTRICAL, TECHNOLOGY, AND

PLUMBING, INCLUDING BUT NOT LIMITED TO PIPING AND CONDUIT RUNS, IN A

MANNER THAT IS CONSISTENT WITH THE EXISTING FLOOR AND WALL

CONSTRUCTION AND FINISH. ALL PENETRATIONS SHALL MEET REQUIRED FIRE

RATINGS.

8. COORDINATE THE INSTALLATION OF ALL OWNER-SUPPLIED EQUIPMENT.

REFERENCE PLANS, SPECS, AND INTERIOR ELEVATIONS FOR SPECIFIC

EQUIPMENT AND ITS INSTALLATION REQUIREMENTS.

9. GENERAL CONTRACTOR SHALL PROVIDE BLOCKING, STIFFENERS, BRACINGS,

BACKING PLATES, SUPPORTING BRACKETS, AND NECESSARY SELECTIVE

DEMOLITION REQUIRED FOR THE PROPER INSTALLATION OF ALL CASEWORK,

TOILET ROOM ACCESSORIES, TOILET PARTITIONS AND MISCELLANEOUS

EQUIPMENT.

10. EXISTING AND INFILL CONCRETE SUB-FLOOR SHALL BE MADE LEVEL, AND IN

SOUND CONDITION AS REQUIRED FOR THE INSTALLATION OF FINAL FLOOR

FINISHES, TYPICAL. PROVIDE ARDEX OR EQUAL LEVELING CONCRETE IF

NECESSARY TO PROVIDE A SMOOTH WALKABLE AREA.

11. ALL RECESSED CABINETS, PANELS, BOXES, ETC. LOCATED IN FIRE-RATED

PARTITIONS SHALL BE INSTALLED IN A MANNER WHICH MAINTAINS THE FIRE

RATED CONSTRUCTION.

12. SEE ENLARGED PLANS FOR NOTES, DIMENSIONS, AND WALL TYPES WITHIN

THE DETAIL CALLOUT BOUNDARIES.

13. REFERENCE SHEET A-002 FOR INTERIOR PARTITION TYPES. INTERIOR

PARTITION TAGS NOTED ENCOMPASS THE ENTIRE LENGTH OF WALL SHOWN

TO CORNERS OF ROOM, OVER AND AROUND DOORWAYS SHOWN.

14. REFERENCE SHEET I-100'S FOR FINISH PLANS.

15. REFERENCE SHEET A-800 SERIES SHEETS FOR SIGNAGE LAYOUTS AND

COORDINATION REQUIREMENTS.

16. REFERENCE SHEET I-700 SERIES SHEETS FOR FURNITURE AND EQUIPMENT

LAYOUTS AND COORDINATION REQUIREMENTS.

LEGEND - PLAN SYMBOLS

ROOM NAME AND NUMBER

WALL TYPE

IDENTIFICATION

KEYED NOTE IDENTIFICATION

WINDOW IDENTIFICATION

DOOR IDENTIFICATION

FLOOR DRAIN

4.XXX

DETAIL SYMBOL

EXTERIOR ELEVATION

SYMBOL

WALL SECTION SYMBOL

INTERIOR ELEVATION

SYMBOL

BUILDING SECTION SYMBOL

FD

FIRE EXTINGUISHER - SURFACE MOUNT

FIRE EXTINGUISHER CABINET AND FIRE

EXTINGUISHER - SEMI-RECESSED

1 HOUR FIRE RATED WALL

ROOM NAME

A-211

A-201

ENLARGED PLAN

SYMBOL

A

XXX

X' - X"

W?

A100

A100

A-101

SIM

A-101

SIM

XXX

X

A-101

A-101

A-101

A-101

F.E.C.

F.E.

EXISTING GRID LINES

NEW GRID LINES

LEVEL OR SPOT ELEVATIONS

ACP-X

10'-10" CEILING HEIGHT & FINISH

MATCHLINE

FF

GG

HH

G.4G.4

A-301

A-302

M A

T C

H L

IN

E

S E

E

A

-1 B

MATCHLINE

SEE 1 / A-101B

A-301

SA3

SA3

1-141

DEPARTURE

LOUNGE

1-145

DEPARTURE

LOUNGE

1-138

VEST.

1-142

VEST.

1-146

VEST.

1-137

AIRSIDE

CONCOURSE

- SOUTH

S2-1

STAIRWELL

1-136

CONCESS

1-102

CIRC

1-154

CIRC

E1-1

ELEV.

1-148

MACH.

1-149

FAMILY

1-152

JAN. CLO.

1-150

FAMILY

1-151

LACT.

A-201B

1-191

VEST

E.4 E.4

E.5 E.5

F.1

F.1

M A

T C

H L

IN

E

S E

E

A

-1 C

M A

T C

H L

IN

E

S E

E

A

-1 C

M A

T C

H L

IN

E

S E

E

A

-1 F

M A

T C

H L

IN

E

S E

E

A

-1 F

1-135

CONCESS

1-134

STORAGE

4.104

4.1474.147

4.142

4.127 4.127

8'-5 1/2"

4.1104.110

4.1104.110 4.1104.110

1-135

KEY PLAN

A

B C

F

ED

G

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com

/3

/2

:4

:1

P

M

.0

-A

-R d e ta c h e d .r v t

D U

R A

N G

O -L

A P

L A

T A

C O

U N

T Y

A

IR

P O

R T

A ir p o rt

R d

D u ra n g o

C

O

D R

O T

E R

M

IN

A L E

X P

A N

S

IO

N A

N D

M O

D E

R N

IZ

A

T

IO

N

P H

A S

E

B

A-101E

1ST FLOOR PLAN -

AREA E

0419000-182253.05

MS

TD, DG

04/08/24

NC

KEYED NOTES

4.104 PAINT PATCH AND REPAIR EXISTING VESTIBULE

4.110 PREPARE WALL FOR FUTURE ART INSTALLATION; FINISH FLOOR TO CEILING

TO A LEVEL 5 FINISH; COORDINATE WITH ARCHITECTURE AND INTERIORS

4.127 GATE COUNTER PODIUM RE: INTERIORS

4.142 LIGHTNING PROTECTION SYSTEM CONDUCTOR LOCATION; INTERIOR TO

BUILDING; INCLUDE ROOF PENETRATION AND CONNECTION TO GROUND

ROD LOCATION; REFER TO ELECTRICAL. DEMO CONCRETE AND WALLS AS

NEEDED; PAINT PATCH AND REPAIR.

4.147 AREA ONLY INCLUDES NEW WALLS, AND DOOR, LEAVE AS SHELL FOR

TENANT IMPROVEMENT

1/8" = 1'-0"1

FIRST FLOOR PLAN - AREA E

09/06/24 CONFORMED SET

428 sf

AIRSIDE

FOOD & BEVERAGE

- SOUTH

NOT FOR CONSTRUCTION

05/01/25 CONCESSIONS RFP

30'-0"

'-1

FLOOR PLAN GENERAL NOTES:

1. SITE DATUM OF FINISHED FIRST FLOOR INDICATED ON SITE PLAN = 100'-0" ON

ARCHITECTURAL DRAWINGS.

2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE

ATTENTION OF THE ARCHITECT/ENGINEER FOR FINAL DECISION.

3. ALL INTERIOR DIMENSIONS ARE FROM FINISH FACE OF WALLS (I.E. GYPSUM

WALLBOARD OR CMU), UNLESS NOTED OTHERWISE. FINISHES MAY EFFECT

ACTUAL DISTANCES, COORDINATE WITH INTERIORS.

4. FLOOR LEVEL ELEVATIONS ARE TO THE TOP OF CONCRETE, UNLESS NOTED

OTHERWISE.

5. REFERENCE SHEET G-011 G-021 AND G-022 FOR ALL CODE, FIRE RATING, AND

SEPARATION REQUIREMENTS.

6. GENERAL CONTRACTOR SHALL PATCH AND REPAIR EXISTING CONSTRUCTION

(WALLS, DOORS, CEILINGS, FLOORS, ETC.) AS REQUIRED FROM DEMOLITION

OR CONSTRUCTION TO ALLOW FOR THE PREP WORK OF NEW OR

COMPLETION OF EXISTING FINISHES. REPAIRS OR REPLACEMENTS MUST BE

DURABLE, SEAMLESS, AND MATCH THE EXISTING MATERIAL.

7. GENERAL CONTRACTOR SHALL PATCH ALL FLOOR AND WALL PENETRATIONS

CAUSED BY DEMOLITION OF MECHANICAL, ELECTRICAL, TECHNOLOGY, AND

PLUMBING, INCLUDING BUT NOT LIMITED TO PIPING AND CONDUIT RUNS, IN A

MANNER THAT IS CONSISTENT WITH THE EXISTING FLOOR AND WALL

CONSTRUCTION AND FINISH. ALL PENETRATIONS SHALL MEET REQUIRED FIRE

RATINGS.

8. COORDINATE THE INSTALLATION OF ALL OWNER-SUPPLIED EQUIPMENT.

REFERENCE PLANS, SPECS, AND INTERIOR ELEVATIONS FOR SPECIFIC

EQUIPMENT AND ITS INSTALLATION REQUIREMENTS.

9. GENERAL CONTRACTOR SHALL PROVIDE BLOCKING, STIFFENERS, BRACINGS,

BACKING PLATES, SUPPORTING BRACKETS, AND NECESSARY SELECTIVE

DEMOLITION REQUIRED FOR THE PROPER INSTALLATION OF ALL CASEWORK,

TOILET ROOM ACCESSORIES, TOILET PARTITIONS AND MISCELLANEOUS

EQUIPMENT.

10. EXISTING AND INFILL CONCRETE SUB-FLOOR SHALL BE MADE LEVEL, AND IN

SOUND CONDITION AS REQUIRED FOR THE INSTALLATION OF FINAL FLOOR

FINISHES, TYPICAL. PROVIDE ARDEX OR EQUAL LEVELING CONCRETE IF

NECESSARY TO PROVIDE A SMOOTH WALKABLE AREA.

11. ALL RECESSED CABINETS, PANELS, BOXES, ETC. LOCATED IN FIRE-RATED

PARTITIONS SHALL BE INSTALLED IN A MANNER WHICH MAINTAINS THE FIRE

RATED CONSTRUCTION.

12. SEE ENLARGED PLANS FOR NOTES, DIMENSIONS, AND WALL TYPES WITHIN

THE DETAIL CALLOUT BOUNDARIES.

13. REFERENCE SHEET A-002 FOR INTERIOR PARTITION TYPES. INTERIOR

PARTITION TAGS NOTED ENCOMPASS THE ENTIRE LENGTH OF WALL SHOWN

TO CORNERS OF ROOM, OVER AND AROUND DOORWAYS SHOWN.

14. REFERENCE SHEET I-100'S FOR FINISH PLANS.

15. REFERENCE SHEET A-800 SERIES SHEETS FOR SIGNAGE LAYOUTS AND

COORDINATION REQUIREMENTS.

16. REFERENCE SHEET I-700 SERIES SHEETS FOR FURNITURE AND EQUIPMENT

LAYOUTS AND COORDINATION REQUIREMENTS.

LEGEND - PLAN SYMBOLS

ROOM NAME AND NUMBER

WALL TYPE

IDENTIFICATION

KEYED NOTE IDENTIFICATION

WINDOW IDENTIFICATION

DOOR IDENTIFICATION

FLOOR DRAIN

4.XXX

DETAIL SYMBOL

EXTERIOR ELEVATION

SYMBOL

WALL SECTION SYMBOL

INTERIOR ELEVATION

SYMBOL

BUILDING SECTION SYMBOL

FD

FIRE EXTINGUISHER - SURFACE MOUNT

FIRE EXTINGUISHER CABINET AND FIRE

EXTINGUISHER - SEMI-RECESSED

1 HOUR FIRE RATED WALL

ROOM NAME

A-211

A-201

ENLARGED PLAN

SYMBOL

A

XXX

X' - X"

W?

A100

A100

A-101

SIM

A-101

SIM

XXX

X

A-101

A-101

A-101

A-101

F.E.C.

F.E.

EXISTING GRID LINES

NEW GRID LINES

LEVEL OR SPOT ELEVATIONS

ACP-X

10'-10" CEILING HEIGHT & FINISH

MATCHLINE

D

E

E

FF

G

HH

5 3 2 1

0.5

0.5

A-302

F.5

A-301

A-201A

A-201B

A-404

A-312

A-313

A-312

A-301

A-313

C.7 C.7

D.3 D.3

D.7 D.7

D.9

D.9

E.4

E.5 E.5

F.1 F.1

F.8 F.8

G.7 G.7

G.8

G.9 G.9

2.2

3.54.3 2.8

M A

T C

H L

IN

E

S E

E

A

-1 G

M A

T C

H L

IN

E

S E

E

A

-1 C

MATCHLINE

SEE 1 / A-101C

1-220.2

SA3

SA6

1-146

VEST.

1-190

DEPARTURE

LOUNGE

1-200

AIRSIDE

CONCOURSE

- NORTH

1-210

DEPARTURE

LOUNGE

E1-1

ELEV.

1-148

MACH.

1-220

HALLWAY

1-195

WOMEN

1-192

MEN

1-194

VEST.

1-191

VEST

4.610

4.620

MATCHLINE

SEE 1 / A-101G

MATCHLINE

SEE 1 / A-101E

M A

T C

H L

IN

E

S E

E

A

-1 E

A-302

A-402

A-402

A-402

FC3

SA6

10'-0"

1-201 4.125

A-2014

A-403

A-313

A-313

A-4042

G.2

D.8

1-227

AIRPORT

STORAGE

1-225

COMM

1-223

TSA LAN

1-222

AIRLINE IT

1-221

ELECT

1-229

UTILITIES

1-219

BOH CIRC

1-168A

CONCESSIONS

BOH

1-168A.1

CONCESSIONS

STORAGE

1-168

CAFE/GIFT

1-228

AIRPORT

STORAGE

1-202

OFFICE

1-226

TSA

STORAGE

1-224A

TSA TRAINING

1-224

BREAK ROOM

1-203

OFFICE

1-214

STOR

1-204

PVT SCREEN

1-213

RETAIL

1-201

PASSENGER

SCREENING

1-215

EXIT LANE

1-235

BAG CLAIM

1-196

KITCHEN

1-197

VEST

1-211

CAFE

FC3

FC3

4.140

.0

4.301

A-201B

A-312

EQ EQ

A-403

4.140

FC1FC1

4.146

A-507

4.142

4.142

FC3

FB6

8'-0"

W11

W10

4.106

4.106

W14

1' - 7 7/8" 9' - 1 5/8"

11 5/8"

7 1/2"

/8

/2

ALIGN

ALIGN

FC1

FC1

ALIGN

9' - 10 3/8" 4 1/4"

A-508

/8

FC6

4.1284.128

ALIGN

FB6

8'-0"

A-606

4.1284.128

4.222

4.223

A-404

A-301

4.111

X-1X-2

2' - 3 3/8"

A-504

KEY PLAN

A

B C

F

ED

G

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com

/3

/2

:4

:1

P

M

.0

-A

-R d e ta c h e d .r v t

D U

R A

N G

O -L

A P

L A

T A

C O

U N

T Y

A

IR

P O

R T

A ir p o rt

R d

D u ra n g o

C

O

D R

O T

E R

M

IN

A L E

X P

A N

S

IO

N A

N D

M O

D E

R N

IZ

A

T

IO

N

P H

A S

E

B

A-101F

1ST FLOOR PLAN -

AREA F

0419000-182253.05

MS

TD, DG

04/08/24

NC

KEYED NOTES

4.106 HSS RE: STRUCT

4.111 SECOND EXIT LANE DEVICE IS ACCEPTED BID ALT #1

4.125 SLIDING SECURITY GRILLE

4.128 SOFFIT AT 8'-0" AFF. CONTINUOUS WOOD PANEL CEILING ABOVE.

4.140 OPENING TO FLOOR IN EXISTING CMU WALL; KEEP 3'-0" MIN CLEAR

4.142 LIGHTNING PROTECTION SYSTEM CONDUCTOR LOCATION; INTERIOR TO

BUILDING; INCLUDE ROOF PENETRATION AND CONNECTION TO GROUND

ROD LOCATION; REFER TO ELECTRICAL. DEMO CONCRETE AND WALLS AS

NEEDED; PAINT PATCH AND REPAIR.

4.146 ATTACH GYPSUM BOARD TO EXPOSED STUDS OR GIRTS ON WALLS,

CEILING, AND EXTERIOR FACE OF SOFFIT

4.222 ALIGN FACE OF SOFFIT ABOVE WITH FACE OF ADJACENT WALL

4.223 WALL TO 10'-0" AFF, CONTINUOUS WOOD CEILING ABOVE

4.301 ARCHITECTURAL FOOT SUPPORT RAIL; 1 1/2" GALVANIZED STEEL PIPE

CONSTRUCTION, TYPICAL. PROVIDE ROBUST ANCHOR TO FLOOR AND WALL.

4.610 EXITING EQUIPMENT; SENSITIVE - INSTALL AFTER NEIGHBORING

CONSTRUCTION IS COMPLETED AND AREA IS FULLY CLEANED

4.620 MECHANICAL EQUIPMENT RE: MECH

1/8" = 1'-0"1

FIRST FLOOR PLAN - AREA F

09/06/24 CONFORMED SET

225 sf

831 sf

AIRSIDE

BAR/CAFE

475 sf

194 sf

AIRSIDE

RETAIL

NOT FOR CONSTRUCTION

05/01/25 CONCESSIONS RFP

13'-1"

'-9

'-1 1"

22'-2"

8' -1

25'-8"

'-9

12'-8"

'-2

S

S S S S SS

S S

S SS

S

S

S S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

DS

DS

DS

DS

DS

S S S S S

CO

ER

H

S

S

S

FS S

CEILING PLAN GENERAL NOTES:

1. SEE ROOM FINISH SCHEDULE FOR FLOOR, WALL AND CEILING FINISHES AND

ROOM HEIGHTS.

2. FIELD VERIFY ALL DIMESIONS, BRING ANY DISCREPANCIES TO THE

ATTENTION OF THE ARCHITECT FOR FINAL DECISION.

3. ALL RECESSED LIGHTS, SPRINKLERS, FIRE DETECTION EQUIPMENT,

OCCUPANCY SENSORS, ETC. SHALL BE CENTERED IN THE TILES UNLESS

NOTED OTHERWISE.

4. CENTER ALL CEILING GRIDS IN SPACE UNLESS NOTED OTHERWISE.

5. ALL METAL LINEAR DIFFUSERS SHALL BE PAINTED TO MATCH SURROUNDING

WALL OR CEILING SURFACE.

2' x 2' SUSPENDED CEILING GRID

LIGHT FIXTURE (RECESSED MOUNTED)

GYPSUM BOARD CEILING/

PORTLAND CEMENT PLASTER (PAINTED)

LIGHT FIXTURE (SURFACE MOUNTED)

SUPPLY AIR DIFFUSER

RETURN AIR DIFFUSER / EXHAUST GRILL

LIGHT FIXTURE (RECESSED CAN)

LIGHT FIXTURE (SURFACE MOUNTED)

EXHAUST FAN

LIGHT FIXTURE (SUSPENDED)

LIGHT FIXTURE (SUSPENDED)OR

CEILING PLAN LEGEND: SEE ELECTRICAL FOR

EXACT FIXTURE MODEL

LIGHT FIXTURE (RECESSED MOUNTED 4" WIDE OR LESS)

8"6"

CEILING RECEPTACLES

CEILING OCCUPANCY SENSOR

CEILING FIRE ALARM DEVICES

CEILING MASS NOTIFICATION DEVICE

CEILING SPEAKER

SPRINKLER HEADS

CEILING SECURITY STRODE

CEILING CAMERA

LIGHT FIXTURE (RECESSED MOUNTED)OR

CEILING PLAN TAG LEGEND:

XX-X

X'-X" ELEVATION ABOVE FINISHED FLOOR

CEILING TYPE

CEILING TYPE TAG

CEILING TAG ABBREVIATION CEILING TYPE

PWC PANELIZED WOOD CEILING

ACT-1 NEW ACCOUSTIC CEILING TILE - 2' X 2'

MPS METAL PANEL SOFFIT

GWB 5/8" GYPSUM BOARD

WL WOOD BAFFLES LUMBER

SP ALUMINUM PLANK SOFFIT

A-301

A-301

A-302

A-312

MATCHLINE

SEE 1 / A-121E

M A

T C

H L

IN

E

S E

E

A

-1 E

M A

T C

H L

IN

E

S E

E

A

-1 G

MATCHLINE

SEE 1 / A-121F

GYP

9'-6"

ACT-1

10'-0"

ACT-1

9'-0"

A-506

WL

8'-4"

ACT-1

9'-0"

ACT-1

9'-0"

A-302

A-302

A-432

A-506

ACT-1

10'-6"

4.189

4.1874.1874.1874.1874.187 4.189

GYP

9'-4"

GYP

9'-4"

TYP

4.191

4.191

4.189

4.189

MATCHLINE

SEE 1 / A-121G

MATCHLINE

SEE 1 / A-121B

M A

T C

H L

IN

E

S E

E

A

-1 B

GYP

9'-4"

ACT-1

9'-0"

4.185

4.185

4.191

4.185

4.185

A-507

A-433

A-508

A-508

A-508

A-508

A-508

A-501

A-508

M A

T C

H L

IN

E

S E

E

A

-1 F

GYP

9'-4"

A-508

GYP

8'-0"

PWC

12'-0"

4.196

A-508

SIM

A-508

4.188

4.188

4.1844.1844.1844.1844.184

4.184

SP

11'-4"

SP

11'-4"

6' - 7 1/2"

4.1984.198

4.198

4.198

4.198

4.191

4.191

/4

28' - 0"

4.226

A-301

/4

4.226

ACT-1

9'-0"

KEY PLAN

A

B C

F

ED

G

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com

/3

/2

:3

:2

P

M C

R e v it L o c a l\

.0

-A -R

C o n c e s s io n s d e ta c h e d m a ry

.s c h a rt m a n

.r v t

D U

R A

N G

O -L

A P

L A

T A

C O

U N

T Y

A

IR

P O

R T

A ir p o rt

R d

D u ra n g o

C

O

D R

O T

E R

M

IN

A L E

X P

A N

S

IO

N A

N D

M O

D E

R N

IZ

A

T

IO

N

P H

A S

E

B

A-121C

1ST FLOOR RCP -

AREA C

0419000-182253.05

MS

TD, DG

04/08/24

NC

1/8" = 1'-0"1

REFLECTED CEILING PLAN - FIRST FLOOR - AREA C

KEYED NOTES

4.184 KEEP EXISTING CEILING (NO DEMO) AS PART OF THE BASE BID

4.185 OPEN TO STRUCTURE

4.187 REINSTALL RETAINED WOOD CEILING FOLLOWING FIRE PROTECTION

UPGRADES

4.188 EXISTING OPEN TO STRUCTURE

4.189 PAINT PATCH AND REPAIR GYP CEILING FOLLOWING FIRE PROTECTION

UPGRADE

4.191 ACCESS PANEL

4.196 SEISMIC SEPARATION JOINT COVER

4.198 GYP CEILING CONTROL JOINT

4.226 HANG BAFFLES FROM 2 POINTS EACH; ALIGN SUSPENSION CABLE

OPENINGS IN GYP CEILING ABOVE 2' FROM END OF BAFFLES, TYPICAL.

09/06/24 CONFORMED SET

LANDSIDE

FOOD & BEV

CMCM

SS

S

S

S

S

S

S

S

S

S

S

S

S

S

S

DS

H

ER

H

M

PS

M

F

M M

CEILING PLAN GENERAL NOTES:

1. SEE ROOM FINISH SCHEDULE FOR FLOOR, WALL AND CEILING FINISHES AND

ROOM HEIGHTS.

2. FIELD VERIFY ALL DIMESIONS, BRING ANY DISCREPANCIES TO THE

ATTENTION OF THE ARCHITECT FOR FINAL DECISION.

3. ALL RECESSED LIGHTS, SPRINKLERS, FIRE DETECTION EQUIPMENT,

OCCUPANCY SENSORS, ETC. SHALL BE CENTERED IN THE TILES UNLESS

NOTED OTHERWISE.

4. CENTER ALL CEILING GRIDS IN SPACE UNLESS NOTED OTHERWISE.

5. ALL METAL LINEAR DIFFUSERS SHALL BE PAINTED TO MATCH SURROUNDING

WALL OR CEILING SURFACE.

2' x 2' SUSPENDED CEILING GRID

LIGHT FIXTURE (RECESSED MOUNTED)

GYPSUM BOARD CEILING/

PORTLAND CEMENT PLASTER (PAINTED)

LIGHT FIXTURE (SURFACE MOUNTED)

SUPPLY AIR DIFFUSER

RETURN AIR DIFFUSER / EXHAUST GRILL

LIGHT FIXTURE (RECESSED CAN)

LIGHT FIXTURE (SURFACE MOUNTED)

EXHAUST FAN

LIGHT FIXTURE (SUSPENDED)

LIGHT FIXTURE (SUSPENDED)OR

CEILING PLAN LEGEND: SEE ELECTRICAL FOR

EXACT FIXTURE MODEL

LIGHT FIXTURE (RECESSED MOUNTED 4" WIDE OR LESS)

8"6"

CEILING RECEPTACLES

CEILING OCCUPANCY SENSOR

CEILING FIRE ALARM DEVICES

CEILING MASS NOTIFICATION DEVICE

CEILING SPEAKER

SPRINKLER HEADS

CEILING SECURITY STRODE

CEILING CAMERA

LIGHT FIXTURE (RECESSED MOUNTED)OR

CEILING PLAN TAG LEGEND:

XX-X

X'-X" ELEVATION ABOVE FINISHED FLOOR

CEILING TYPE

CEILING TYPE TAG

CEILING TAG ABBREVIATION CEILING TYPE

PWC PANELIZED WOOD CEILING

ACT-1 NEW ACCOUSTIC CEILING TILE - 2' X 2'

MPS METAL PANEL SOFFIT

GWB 5/8" GYPSUM BOARD

WL WOOD BAFFLES LUMBER

SP ALUMINUM PLANK SOFFIT

A-301

A-302

M A

T C

H L

IN

E

S E

E

A

-1 B

MATCHLINE

SEE 1 / A-121B

A-301

ACT-1

10'-6"

ACT-1

10'-6"

ACT-1

10'-6"

ACT-1

10'-6"

ACT-1

10'-6"

ACT-1

10'-6"

GYP

9'-10"

M A

T C

H L

IN

E

S E

E

A

-1 F

M A

T C

H L

IN

E

S E

E

A

-1 F

4.191

4.1894.1894.189

4.189 4.189

4.1894.189

4.151

M A

T C

H L

IN

E

S E

E

A

-1 C

M A

T C

H L

IN

E

S E

E

A

-1 C

KEY PLAN

A

B C

F

ED

G

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com

/3

/2

:3

:3

P

M C

R e v it L o c a l\

.0

-A -R

C o n c e s s io n s d e ta c h e d m a ry

.s c h a rt m a n

.r v t

D U

R A

N G

O -L

A P

L A

T A

C O

U N

T Y

A

IR

P O

R T

A ir p o rt

R d

D u ra n g o

C

O

D R

O T

E R

M

IN

A L E

X P

A N

S

IO

N A

N D

M O

D E

R N

IZ

A

T

IO

N

P H

A S

E

B

A-121E

1ST FLOOR RCP -

AREA E

0419000-182253.05

MS

TD, DG

04/08/24

NC

KEYED NOTES

4.151 TRANSLUCENT PANEL SKYLIGHT

4.189 PAINT PATCH AND REPAIR GYP CEILING FOLLOWING FIRE PROTECTION

UPGRADE

4.191 ACCESS PANEL

1/8" = 1'-0"1

REFLECTED CEILING PLAN - FIRST FLOOR -AREA E

09/06/24 CONFORMED SET

AIRSIDE

FOOD & BEVERAGE

- SOUTH

CM

CM

C M

S

S S

S

S

S

S S

SS

S

S

S

S

S

S S

S

SS

S

S

S

S S

S

S

S

S

S

S

S

S

S

DS

DS

DS

CM

CO

S

S

M

M

CK

M

P

O

OO

F

M

CEILING PLAN GENERAL NOTES:

1. SEE ROOM FINISH SCHEDULE FOR FLOOR, WALL AND CEILING FINISHES AND

ROOM HEIGHTS.

2. FIELD VERIFY ALL DIMESIONS, BRING ANY DISCREPANCIES TO THE

ATTENTION OF THE ARCHITECT FOR FINAL DECISION.

3. ALL RECESSED LIGHTS, SPRINKLERS, FIRE DETECTION EQUIPMENT,

OCCUPANCY SENSORS, ETC. SHALL BE CENTERED IN THE TILES UNLESS

NOTED OTHERWISE.

4. CENTER ALL CEILING GRIDS IN SPACE UNLESS NOTED OTHERWISE.

5. ALL METAL LINEAR DIFFUSERS SHALL BE PAINTED TO MATCH SURROUNDING

WALL OR CEILING SURFACE.

2' x 2' SUSPENDED CEILING GRID

LIGHT FIXTURE (RECESSED MOUNTED)

GYPSUM BOARD CEILING/

PORTLAND CEMENT PLASTER (PAINTED)

LIGHT FIXTURE (SURFACE MOUNTED)

SUPPLY AIR DIFFUSER

RETURN AIR DIFFUSER / EXHAUST GRILL

LIGHT FIXTURE (RECESSED CAN)

LIGHT FIXTURE (SURFACE MOUNTED)

EXHAUST FAN

LIGHT FIXTURE (SUSPENDED)

LIGHT FIXTURE (SUSPENDED)OR

CEILING PLAN LEGEND: SEE ELECTRICAL FOR

EXACT FIXTURE MODEL

LIGHT FIXTURE (RECESSED MOUNTED 4" WIDE OR LESS)

8"6"

CEILING RECEPTACLES

CEILING OCCUPANCY SENSOR

CEILING FIRE ALARM DEVICES

CEILING MASS NOTIFICATION DEVICE

CEILING SPEAKER

SPRINKLER HEADS

CEILING SECURITY STRODE

CEILING CAMERA

LIGHT FIXTURE (RECESSED MOUNTED)OR

CEILING PLAN TAG LEGEND:

XX-X

X'-X" ELEVATION ABOVE FINISHED FLOOR

CEILING TYPE

CEILING TYPE TAG

CEILING TAG ABBREVIATION CEILING TYPE

PWC PANELIZED WOOD CEILING

ACT-1 NEW ACCOUSTIC CEILING TILE - 2' X 2'

MPS METAL PANEL SOFFIT

GWB 5/8" GYPSUM BOARD

WL WOOD BAFFLES LUMBER

SP ALUMINUM PLANK SOFFIT

A-302

A-301

A-312

A-313

A-312

A-301

A-313

A-504

M A

T C

H L

IN

E

S E

E

A

-1 G

M A

T C

H L

IN

E

S E

E

A

-1 C

M A

T C

H L

IN

E

S E

E

A

-1 C

ACT-1

9'-0"

ACT-1

9'-0"

ACT-1

9'-0"

ACT-1

9'-0"

ACT-1

9'-0"

GYP

10'-0"

A-506

4.181

PWC

12'-0"

TYP

SIM

M A

T C

H L

IN

E

S E

E

A

-1 E

GYP

8'-0"

A-507

A-507

PWC

VARIES

PWC

VARIES

4.181

PWC

VARIES

TYP

SIM

A-302

A-313

A-313

4.191

MATCHLINE

SEE 1 / A-101G

4.191

PWC

12'-0"

SP

9'-4"

PWC

SLOPE: 3"/12"

PWC

SLOPE: 3"/12"

PWC

SLOPE: 8"/12"

PWC

FLAT

4.185

4.185 4.185

4.185

4.185 4.185

ACT-1

9'-0"

ACT-1

9'-0"

PWC

VARIES

4.193

GYP

8'-0"

GYP

8'-0"

GYP

8'-0"

GYP

8'-5"

A-312

4.1844.184

4.184 4.184

4.1844.184

A-507

A-507

A-507

A-506

A-506

4.184

4.184

GYP

9'-4"

A-508

A-508

GYP

8'-0"

FC1

A-312

A-121F

A-301

PWC

12'-0"

A-504

A-312

2" 1" 6' - 0 5/8"

A-506

A-506

A-506

3/4"

4.227

4.197

GYP

11'-6"

WL

10'-0"

4.226

4.226

4.230

KEY PLAN

A

B C

F

ED

G

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com

/3

/2

:3

:3

P

M C

R e v it L o c a l\

.0

-A -R

C o n c e s s io n s d e ta c h e d m a ry

.s c h a rt m a n

.r v t

D U

R A

N G

O -L

A P

L A

T A

C O

U N

T Y

A

IR

P O

R T

A ir p o rt

R d

D u ra n g o

C

O

D R

O T

E R

M

IN

A L E

X P

A N

S

IO

N A

N D

M O

D E

R N

IZ

A

T

IO

N

P H

A S

E

B

A-121F

1ST FLOOR RCP -

AREA F

0419000-182253.05

MS

TD, DG

04/08/24

NC

KEYED NOTES

4.181 LIGHT FIXTURE RE: ELEC, TYP

4.184 KEEP EXISTING CEILING (NO DEMO) AS PART OF THE BASE BID

4.185 OPEN TO STRUCTURE

4.191 ACCESS PANEL

4.193 EXIT LANE AREA OPEN TO HIGH CEILING ABOVE

4.197 STRAIGHT ALIGNMENT OF WOOD CEILING MEMBER ENDS

4.226 HANG BAFFLES FROM 2 POINTS EACH; ALIGN SUSPENSION CABLE

OPENINGS IN GYP CEILING ABOVE 2' FROM END OF BAFFLES, TYPICAL.

4.227 ALL BAFFLE SPANS OVER 10'-0" TO BE 2 SEPARATE BAFFLES. ONE 8'0"

BAFFLE ON THE NORTH SIDE WITH A 3/4" GAP TO SHORTER BAFFLE.

4.230 2" GAP BETWEEN GYP CEILING AND FACE OF INTERIOR FINISH ON FURRED

CMU WALL

1/8" = 1'-0"1

REFLECTED CEILING PLAN - FIRST FLOOR -AREA F

1/4" = 1'-0"2

ENLARGED REFLECTED CEILING PLAN - WL CEILING ARRAY

09/06/24 CONFORMED SET

AIRSIDE

BAR/CAFE

AIRSIDE

RETAIL

C

DD

2.8

6'-7" 13'-9"

/8

C E

N T

E R

O P

E N

IN

G

T O

C L

O S

E S

T F

U L

L C

M U

B L

O C

K

/8

FC6

AD 3 FC6

SA6

SA6FC3

1-168.2

1-168A.1

1-168.1FC6

FC6

/4

/2

11'-3 3/4" 3'-1"

SA3

SA6

SA6

4.125

4.024

SA3

4 3/4" 14'-0"

1-168

CAFE/GIFT

1-168A

CONCESSIONS

BOH

1-168A.1

CONCESSIONS

STORAGE

1-168B

KITCHEN

A-606

SIM

A-606

/8

4.179

1'-6 1/8"

SIM

W17

A-4045

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com

/3

/2

:4

:3

P

M

.0

-A

-R d e ta c h e d .r v t

D U

R A

N G

O -L

A P

L A

T A

C O

U N

T Y

A

IR

P O

R T

A ir p o rt

R d

D u ra n g o

C

O

D R

O T

E R

M

IN

A L E

X P

A N

S

IO

N A

N D

M O

D E

R N

IZ

A

T

IO

N

P H

A S

E

B

A-401

ENLARGED PLANS

AND ELEVATIONS

0419000-182253.05

NJC, MES

JC, TD

04/08/24

NJC

KEYED NOTES

4.024 SALVAGE EXISTING DOOR AND REORIENT PER PLAN

4.125 SLIDING SECURITY GRILLE

4.179 CASEWORK RE: INTERIORS

1/4" = 1'-0"1

LANDSIDE CONCESSIONS - PLAN

09/06/24 CONFORMED SET

599 sf

239 sf 119 sf

838 sf

LANDSIDE

FOOD & BEV

DD

A-301

D.3 D.3

D.7 D.7

E.5 E.5

F.1 F.1

1-214

1-204

1-203

1-224.

This is the start of the file's text. The full file is on GovTribe.