Comm Pool Steel Framing Repair Drawings 1.3.24.pdf
PDF 2 MB Posted
- Attached to
- Tecumseh Public Schools RFP Pool Roof Repair
- Solicitation number
- RFP - LIS - 240000001246
- Issued by
- Lenawee County, Michigan
About this file
This document is the Tecumseh Memorial Pool Roof Framing Steel Repairs project specifications issued for bid by Tecumseh Public Schools located in Tecumseh, Michigan. The project involves the repair of the existing steel roof framing at the Tecumseh Memorial Pool facility. Key details include the demolition and replacement of corroded steel members, installation of new steel HSS joist bearing reinforcing, and the addition of new steel WT beam seats along the north wall. The work is to be performed in accordance with the 2015 Michigan Building Code and Rehabilitation Code. Bids for this project are due on December 22, 2023.
Regarding pricing, the specifications do not mention any set-aside requirements, incumbent contractors, or funding sources. However, the project is for a public school district, so the pricing and award will likely be subject to typical government procurement regulations and processes. The document also does not provide any further details on the overall project budget, schedule, or contract term.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Community Pool Roof Repair RFP - Project Manual-compressed.pdf | ||
| RFP Required Documents.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISSUED FOR BID
NOT FOR
CONSTRUCTION
Project
Project Location
Sheet Name
No. Issued For
\\s m e-in c\ pz
\W
IP
\0
2.
\C
AD
\D es ig n Fi le s\
M
AT
\R ev
1\
.0 0-
CO
VE
R.
dw g
NO REPRODUCTION SHALL BE MADE WITHOUT THE PRIOR
CONSENT OF SME
c
DRAWING NOTE: SCALE DEPICTED IS MEANT FOR 11" X 17"
AND WILL SCALE INCORRECTLY IF PRINTED ON ANY
OTHER SIZE MEDIA
PL
O
T D
AT
E:
D ec
2,
- 1
1:
am gu s.
ku rd i www.sme-usa.com
SME Project No.
Project Manager:
CADD:
Checked By:
Sheet No.
Date:
Designer:
Reviewed By:
Date
307 MAUMEE ST.
TECUMSEH, MI
49286
TECUMSEH
MEMORIAL POOL
ROOF FRAMING
STEEL REPAIRS
G0.1
BID 12-22-23
RCI
RCI
12-22-23
093942.00
NS
NS
GUS
COVER SHEET
SHEET NO. SHEET TITLE
G0.1 COVER SHEET
LIST OF DRAWINGS:
NORTH WALL ROOF FRAMING SECTIONS AND DETAILS
Tecumseh Memorial Pool Roof Framing Steel Repairs Tecumseh, Michigan 49286
N
S
W E
NOT TO SCALE
NOT TO SCALE
LOCATION MAP - MAP VIEW
LOCATION MAP - SATELLITE VIEW
SME
43980 PLYMOUTH OAKS BLVD
PLYMOUTH, MI 48170
734-454-9900
CONTACT: NATE SEXTON, PE
nate.sexton@sme-usa.com
SME PROJECT NO. 093942.00
ENGINEER
TECUMSEH PUBLIC SCHOOLS
307 MAUMEE ST
TECUMSEH, MI 49286
CONTACT: JOSH MATTISON
DIRECTOR OF OPERATIONS
jmattison@tps.k12.mi.us
OWNER / CLIENT
APPLICABLE CODES
SITE
WORK AREA
N
S
W E
EXISTING CONSTRUCTION
1. EXISTING DIMENSIONS AND CONDITIONS SHOWN
ON DRAWING ARE BASED UPON ORIGINAL DESIGN
DRAWINGS AND CURSORY FIELD OBSERVATIONS.
FIELD-MEASURE EXISTING DIMENSIONS PRIOR TO
SHOP DRAWING PREPARATION AND FABRICATION
AND REPORT ANY DISCREPANCIES TO THE
ENGINEER.
2. EXISTING CONSTRUCTION NOT UNDERGOING
ALTERATION SHALL REMAIN UNDISTURBED. WHERE
EXISTING CONSTRUCTION IS DISTURBED, REPAIR OR
REPLACE DISTURBED ITEMS TO THE OWNER'S
SATISFACTION.
3. PROVIDE APPROPRIATE FIRE WATCH DURING FIELD
CUTTING AND WELDING OPERATIONS TO FULLY
PROTECT OWNER'S PROPERTY.
4. REMOVE CORRODED / UNSOUND STEEL FROM
EXISTING STEEL SURFACES TO BE WELDED BY
APPROPRIATE MEANS USING NON DUST
PRODUCING EQUIPMENT.
STRUCTURAL STEEL
1. FABRICATE AND ERECT STRUCTURAL STEEL IN
ACCORDANCE WITH THE AMERICAN INSTITUTE OF
STEEL CONSTRUCTION (AISC) 360, “SPECIFICATION
FOR STRUCTURAL STEEL BUILDINGS”, THE STEEL
CONSTRUCTION MANUAL (FOURTEENTH EDITION),
AND AISC 303, “CODE OF STANDARD PRACTICE FOR
STEEL BUILDINGS AND BRIDGES”.
2. PROVIDE STRUCTURAL STEEL CONFORMING TO THE
FOLLOWING ASTM SPECIFICATIONS, U.N.O:
HSS ASTM A500 GRADE C
STRUCTURAL TEE (WT) ASTM A992
3. ALL STRUCTURAL STEEL SHALL BE HOT-DIPPED
GALVANIZED IN ACCORDANCE WITH ASTM A123.
4. WELDING SHALL BE MADE USING APPROPRIATE
E70XX LOW HYDROGEN ELECTRODES COMPATIBLE
WITH THE STEEL BEING JOINED. WELDERS SHALL BE
QUALIFIED FOR THE TYPE OF WELDING PERFORMED,
IN ACCORDANCE WITH THE “STRUCTURAL WELDING
CODE-STEEL,” AWS D1.1, OF THE AMERICAN
WELDING SOCIETY.
5. WHERE FIELD-WELDING TO EXISTING STRUCTURAL
STEEL IS INDICATED, THOROUGHLY CLEAN ALL
SURFACES TO RECEIVE WELD, REMOVING DUST,
PAINT, DIRT, AND OTHER FOREIGN MATTER IN AREA
OF WORK.
S1.1
2015 MICHIGAN BUILDING CODE
2015 MICHIGAN REHABILITATION CODE
COL
V9
REPAIR SECTION2
SCALE: 11
2" = 1'-0"
EXISTING TYPICAL
NORTH WALL SECTION1
SCALE: 11
2" = 1'-0"
SECTION4
SCALE: 11
2" = 1'-0"
V9
SECTION3
SCALE: 11
2" = 1'-0"
EX C4
EX C12
EX W21
OR W16
EX W10
COLUMN
REFER TO
NOTE A
EX CMU
EX JOIST
EX ROOF DECK
V9
CEILING LINE
RE
FE
R
TO
O
RI
G
IN
AL
D
ES
IG
N D
RA
W
IN
G
SH
EE
T N
O . A
FO
R
CE
IL
IN
G A
N D
D U
CT
W
H
IC
H M
AY
R
EQ
U
IR
E
RE
M
O
VA
L
TO
D O
W O
RK
S
H O
W N
41 4"
VI
F
EX SHIM
PLATE
EX 2∠4x4 JOIST
BEARING
EX ∠31
2x31
FITTED HSS21
2x2x1
4, TYP
EX CMU
TO REMAIN
REMOVE CMU AS
REQUIRED TO INSTALL
WT BEAM SEATS AND
RESTORE CMU TO
ORIGINAL CONDITION
FOLLOWING
INSTALLATION
EX END WEB
- DIAGONAL ∠2x2
WT9x25x41
2" LONG, TYP
REFER TO NOTE A
EX CMU FACE
3/16
HSS
2"41
2"
3/16
3/16 2 3/16 2
WT
NOTE:
CMU NOT
SHOWN
FOR
CLARITY
2"
NOTE B6 PLACES
WT SEAT
CMU TO BE
REMOVED
FOR WT SEAT
INSTALLATION
3' -4
'-0
TO
F F
EL
'-0
5" JO
IS
T
SE
AT
EL 24'-3"
T/EX W21
OR W16
BRG SHOE REINF
REFER TO NOTE B
8" PROJECTED
CMU COL COVER
(12) LOCATIONS
NOTE A
NOTE B:
HSS JOIST BEARING SHOE
REINFORCING REQUIRED
AT ALL (22) JOIST BEARING
LOCATIONS ALONG
COLUMN LINE V9
NOTE A:
WT SEAT REQUIRED
(12) LOCATIONS: BOTH SIDES OF
COLUMN - AT LINES H2 THROUGH H7
AND ONE SIDE AT COLUMN LINES H1
AND H8 ALONG COLUMN LINE V9
ISSUED FOR BID
NOT FOR
CONSTRUCTION
Project
Project Location
Sheet Name
No. Issued For
\\s m e-in c\ pz
\W
IP
\0
2.
\C
AD
\D es ig n Fi le s\
M
AT
\R ev
1\
.0 0-
D
ET
AI
L.
dw g
NO REPRODUCTION SHALL BE MADE WITHOUT THE PRIOR
CONSENT OF SME
c
DRAWING NOTE: SCALE DEPICTED IS MEANT FOR 11" X 17"
AND WILL SCALE INCORRECTLY IF PRINTED ON ANY
OTHER SIZE MEDIA
PL
O
T D
AT
E:
D ec
2,
- 8
:4 9a m gu s.
ku rd i www.sme-usa.com
SME Project No.
Project Manager:
CADD:
Checked By:
Sheet No.
Date:
Designer:
Reviewed By:
Date
307 MAUMEE ST.
TECUMSEH, MI
49286
TECUMSEH
MEMORIAL POOL
ROOF FRAMING
STEEL REPAIRS
S1.1
BID 12-22-23
RCI
RCI
12-22-23
093942.00
NS
NS
GUS
NORTH WALL ROOF
FRAMING SECTIONS
AND DETAILS
| Sheets and Views |
| G0.1 |
| Sheets and Views |
| S1.1 |
File details come from the government source that posted it. Updated .