CMS Back on Campus Phase II Submittal Matrix 75 Percent CD.pdf
PDF 364 KB Posted
- Attached to
- CMS Back on Campus Phase II Federal contract opportunity
- Solicitation number
- 47PD0221R0072
About this file
This submittal matrix outlines the submittal requirements for a renovation project at the Centers for Medicare and Medicaid Services campus in Windsor Mill, Maryland. The project includes renovations totaling approximately 40,000 square feet across four areas: Central Building Level 2, South Building Lower Level, Central Building Lower Level, and the Main Lobby in the Central Building Level 1.
The matrix lists over 100 specification sections and identifies the required submittals for each including product data, shop drawings, samples, coordination drawings, test reports, warranties, and other documentation. It indicates the General Services Administration as the contracting agency and provides a point of contact. The related federal contract opportunity details an estimated value between $10-15 million for the project and identifies evaluation criteria for the best value proposal including project management plan, experience, past performance, and price. The solicitation number and response due date are also provided.
View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Submittals Report Generated: February 22, 2022
Action Submittals Information Submittals
Section
P ro d u c t
D a ta
L E
E D
S u b m it ls
S h o p
D ra w in g s m p le m p le s f o r
In it ia l S e le c ti o n m p le s f o r
V e ri fi c a ti
F b ri c S a m p le s f o r
V e ri fi c a ti ro d u c t
D o o r
H a rd w a re
S c h e d u
D e le g a te d -D e s ig n S u b m it ta l
P ro d u c t
L is t
S U
B M
IT
T
A
C o rd in a ti o n D ra w in
Q a lif ic a ti o n S ta te m e ts is m ic Q u a lif ic a ti
W ld in g C e rt if ic a te
M te ri a l/ P ro d u c t
C e rt if ic a te ri a l T e s t
R e p o rt d u c t
T e s t
R e p o
R s e a rc h /E v a lu a ti o n R e p o re c o n s tr u c ti o n T e s t
R e p o u rc e Q u a lit y -C o n tr o l R e p o ie ld Q u a lit y -C o n tr o l R e p o rr a ty m p a ti b ili ty
T e s t
R e p o m p a ti b ili ty
A n d A d h e s io s ig n D ld T e s t
R e p o
In ta lle r
C e rt if ic a n u fa c tu re r
C e rt if ic a n u fa c tu re r' s F ie ld
R e p o
O v e rs iz e C o n s tr u c ti ir in g d ia g ra m
024119 - SELECTIVE
DEMOLITION
030130 - MAINTENANCE OF
CAST-IN-PLACE CONCRETE
035416 - HYDRAULIC CEMENT
UNDERLAYMENT
055000 - METAL FABRICATIONS
057000 - DECORATIVE METAL
057313 - GLAZED DECORATIVE
METAL RAILINGS
061053 - MISCELLANEOUS
ROUGH CARPENTRY
064116 - PLASTIC-LAMINATE-
CLAD ARCHITECTURAL
CABINETS
064216 - FLUSH WOOD
PANELING
ro d u c t
D
E D
S u b m it o p
D ra w in m p m p le s f o r
In it ia l S e le c ti m p le s f o r
V e ri fi c a ti b ri c S a m p le s f o r
V e ri fi c a ti d u c t
D o o r
H a rd w a re
S c h e d le g a te d -D e s ig n S u b m it ta l
P ro d u c t
L is t
S U
B M
IT
T
A o rd in a ti o n D ra w in a lif ic a ti o n S ta te m e is m ic Q u a lif ic a ti ld in g C e rt if ic a te ri a l/ P ro d u c t
C e rt if ic a te ri a l T e s t
R e p o d u c t
T e s t
R e p o s e a rc h /E v a lu a ti o n R e p o c o n s tr u c ti o n T e s t
R e p o u rc e Q u a lit y -C o n tr o l R e p o ld Q u a lit y -C o n tr o l R e p o rr a m p a ti b ili ty
T e s t
R e p o m p a ti b ili ty
A n d A d h e s s ig n D ld T e s t
R e p o ta lle r
C e rt if ic a n u fa c tu re r
C e rt if ic a n u fa c tu re r' s F ie ld
R e p o e rs iz e C o n s tr u c ti in g d ia g ra
078413 - PENETRATION
FIRESTOPPING
078443 - JOINT FIRESTOPPING
079200 - JOINT SEALANTS
079219 - ACOUSTICAL JOINT
SEALANTS
081113 - HOLLOW METAL DOORS
AND FRAMES
081416 - FLUSH WOOD DOORS
083113 - ACCESS DOORS AND
FRAMES
084126.23 - INTERIOR ALL-GLASS
ENTRANCES
08 71 00_Door_Hardware_2021-11-
088000 - GLAZING
088300 - MIRRORS
088700 - GLAZING FILM
090190.52 - MAINTENANCE
REPAINTING
ro d u c t
D
E D
S u b m it o p
D ra w in m p m p le s f o r
In it ia l S e le c ti m p le s f o r
V e ri fi c a ti b ri c S a m p le s f o r
V e ri fi c a ti d u c t
D o o r
H a rd w a re
S c h e d le g a te d -D e s ig n S u b m it ta l
P ro d u c t
L is t
S U
B M
IT
T
A o rd in a ti o n D ra w in a lif ic a ti o n S ta te m e is m ic Q u a lif ic a ti ld in g C e rt if ic a te ri a l/ P ro d u c t
C e rt if ic a te ri a l T e s t
R e p o d u c t
T e s t
R e p o s e a rc h /E v a lu a ti o n R e p o c o n s tr u c ti o n T e s t
R e p o u rc e Q u a lit y -C o n tr o l R e p o ld Q u a lit y -C o n tr o l R e p o rr a m p a ti b ili ty
T e s t
R e p o m p a ti b ili ty
A n d A d h e s s ig n D ld T e s t
R e p o ta lle r
C e rt if ic a n u fa c tu re r
C e rt if ic a n u fa c tu re r' s F ie ld
R e p o e rs iz e C o n s tr u c ti in g d ia g ra
092216 - NON-STRUCTURAL
METAL FRAMING
092900 - GYPSUM BOARD
093013 - CERAMIC TILING
095113 - ACOUSTICAL PANEL
CEILINGS
095423 - LINEAR METAL
CEILINGS
096513 - RESILIENT BASE AND
ACCESSORIES
096519 - RESILIENT TILE
FLOORING
096613 - PORTLAND CEMENT
TERRAZZO FLOORING
096813 - TILE CARPETING
098433 - SOUND-ABSORBING
WALL UNITS
099123 - INTERIOR PAINTNG
ro d u c t
D
E D
S u b m it o p
D ra w in m p m p le s f o r
In it ia l S e le c ti m p le s f o r
V e ri fi c a ti b ri c S a m p le s f o r
V e ri fi c a ti d u c t
D o o r
H a rd w a re
S c h e d le g a te d -D e s ig n S u b m it ta l
P ro d u c t
L is t
S U
B M
IT
T
A o rd in a ti o n D ra w in a lif ic a ti o n S ta te m e is m ic Q u a lif ic a ti ld in g C e rt if ic a te ri a l/ P ro d u c t
C e rt if ic a te ri a l T e s t
R e p o d u c t
T e s t
R e p o s e a rc h /E v a lu a ti o n R e p o c o n s tr u c ti o n T e s t
R e p o u rc e Q u a lit y -C o n tr o l R e p o ld Q u a lit y -C o n tr o l R e p o rr a m p a ti b ili ty
T e s t
R e p o m p a ti b ili ty
A n d A d h e s s ig n D ld T e s t
R e p o ta lle r
C e rt if ic a n u fa c tu re r
C e rt if ic a n u fa c tu re r' s F ie ld
R e p o e rs iz e C o n s tr u c ti in g d ia g ra
101423.16 - ROOM-
IDENTIFICATION PANEL
SIGNAGE
102113.17 - PHENOLIC-CORE
TOILET COMPARTMENTS
102219 - DEMOUNTABLE
PARTITIONS
102600 - WALL AND DOOR
PROTECTION
102800 - TOILET, BATH, AND
LAUNDRY ACCESSORIES
104413 - FIRE PROTECTION
CABINETS
104416 - FIRE EXTINGUISHERS
122413 - ROLLER WINDOW
SHADES
123661.16 - SOLID SURFACING
COUNTERTOPS
SECTION 024119 - SELECTIVE DEMOLITION
Submittal Matrix – Divisions 21, 22, 23, 26, 27, 28
75%CD
Action Submittals ro d u ct
D at a
L E
E D
S u b m it o p
D ra w in g s
S am p le s
S am p le s fo r In it ia l S el ec ti am p le s fo r V er if ic at ab ri c
S am p le s fo r V er if ic at d ct el eg at ed -D es ig n S u b m it ta l
P ro d u ct L is t
S U
B M
IT
T
A
210000 – FIRE PROTECTION
210517 – SLEEVES AND SEALS FOR
FIRE SUPPRESSION
210520 – PIPING AND FITTING
MATERIALS
210529 – HANGERS, SUPPORTS,
ANCHORS AND GUIDES FOR FIRE
SUPPRESSION SYSTEMS
211313 – WET PIPE SPRINKLER
SYSTEMS
220000 – PLUMBING
220517 – SLEEVES AND SLEEVE
SEALS FOR PLUMBING PIPING
ro d u ct D at a
L E
E D
S u b m it o p
D ra w in g s
S am p le s
S am p le s fo r In it ia l S el ec ti p le s fo r V er if ic at ri c
S am p le s fo r V er if ic at d eg at ed -D es ig n S u b m it ta l
P ro d u ct L is t
S U
B M
IT
T
A
220523 - VALVES ✓ ✓ ✓
220529 – HANGERS, SUPPORTS,
ANCHORS AND GUIDES
220530 – DISINFECTING OF WATER
SUPPLY SYSTEM
220590 - TESTING ✓
220719 - INSULATION ✓ ✓
221116 – DOMESTIC WATER PIPING
AND FITTING MATERIALS
221316 – SANITARY WASTE AND
VENT PIPING AND FITTING
MATERIALS
223300 – ELECTRIC DOMESTIC
WATER HEATERS
224200 – COMMERCIAL PLUMBING
FIXTURE AND TRIM
ro d u ct D at a
L E
E D
S u b m it o p
D ra w in g s
S am p le s
S am p le s fo r In it ia l S el ec ti p le s fo r V er if ic at ri c
S am p le s fo r V er if ic at d eg at ed -D es ig n S u b m it ta l
P ro d u ct L is t
S U
B M
IT
T
A
230000 – HVAC
230002 – HEATING, VENTILATING
AND AIR CONDITIONING GENERAL
CONDITIONS
230200 - FIRESTOPPING ✓ ✓
230516 – EXPANSION FITTINGS AND
LOOPS FOR HVAC PIPING
230519 – METERS AND GAUGES FOR
HVAC PIPING AND DUCTWORK
230523 – VALVES ✓ ✓
230529 – HANGERS, ANCHORS,
SUPPORTS AND SEISMIC
RESTRAINTS
230548 – VIBRATION ISOLATION ✓ ✓ ✓ ✓
230553 – SYSTEMS IDENTIFICATION ✓ ✓
ro d u ct D at a
L E
E D
S u b m it o p
D ra w in g s
S am p le s
S am p le s fo r In it ia l S el ec ti p le s fo r V er if ic at ri c
S am p le s fo r V er if ic at d eg at ed -D es ig n S u b m it ta l
P ro d u ct L is t
S U
B M
IT
T
A
230593 – TESTING, ADJUSTING AND
BALANCING
230700 - INSULATION ✓ ✓
230923 – BUILDING MANAGEMENT
AND CONTROL SYSTEM (BMCS)
231113 – SHEET METAL, DUCTWORK
AND ACCESSORIES
233313 – DAMPERS ✓ ✓ ✓
233320 – DUCT CLEANING ✓ ✓
233600 – AIR TERMINAL UNITS ✓ ✓
233610 – AIR OUTLETS AND INLETS ✓ ✓ ✓
234100 – AIR FILTERS AND
CLEANERS
235210 – PIPING AND ACCESSORIES ✓ ✓ ✓
260000 – ELECTRICAL
ro d u ct D at a
L E
E D
S u b m it o p
D ra w in g s
S am p le s
S am p le s fo r In it ia l S el ec ti p le s fo r V er if ic at ri c
S am p le s fo r V er if ic at d eg at ed -D es ig n S u b m it ta l
P ro d u ct L is t
S U
B M
IT
T
A
260001 – ELECTRICAL GENERAL
CONDITIONS
260005 – ACCESS DOORS IN
GENERAL CONSTRUCTION
260265 – TESTING, ADJUSTING AND
BALANCING
260270 – TEMPORARY LIGHTING AND
POWER
260280 – EQUIPMENT CONNECTIONS
AND COORDINATION
260290 – CEILING, FLOOR AND WALL
ELECTRICAL PENETRATION FIRE
SEALS
260519 – 600 VOLT WIRE AND CABLE ✓
260526 – GROUNDING SYSTEM ✓ ✓
260533 – RACEWAYS AND BOXES ✓ ✓
ro d u ct D at a
L E
E D
S u b m it o p
D ra w in g s
S am p le s
S am p le s fo r In it ia l S el ec ti p le s fo r V er if ic at ri c
S am p le s fo r V er if ic at d eg at ed -D es ig n S u b m it ta l
P ro d u ct L is t
S U
B M
IT
T
A
260548 – VIBRATION ISOLATION AND
SEISMIC RESTRAINTS
260553 – IDENTIFICATION FOR
ELECTRICAL SYSTEM
260800 – COMMISSIONING OF
ELECTRICAL SYSTEMS
260960 – RELAYS AND REMOTE
CONTROL SWITCHES
262200 – LOW-VOLTAGE
DISTRIBUTION TRANSFORMERS
262416 - PANELBOARDS ✓ ✓ ✓ ✓ ✓
262726 – WIRING DEVICES ✓ ✓
262730 – ACCESS FLOOR DELIVERY
MODULES
262813 – FUSES (600 V AND LESS) ✓ ✓
262816 – DISCONNECT SWITCHES ✓ ✓
ro d u ct D at a
L E
E D
S u b m it o p
D ra w in g s
S am p le s
S am p le s fo r In it ia l S el ec ti p le s fo r V er if ic at ri c
S am p le s fo r V er if ic at d eg at ed -D es ig n S u b m it ta l
P ro d u ct L is t
S U
B M
IT
T
A
262913 – INSTALLATION OF
INDIVIDUAL MOTOR CONTROLLERS
264000 – FIRE ALARM LIFE SYSTEM ✓ ✓ ✓
265000 – LUMINAIRES AND
ACCESSORIES
265006 – LIGHTING CONTROL
DEVICES
265100 – ARCHITECTURAL LIGHTING ✓ ✓ ✓
270000 – TELECOMMUNICATIONS
270526 – GROUNDING AND BONDING
FOR COMMUNICATIONS SYSTEMS
270528 -RE-ENTERABLE FIRE RATED
PATHWAYS FOR COMMUNICATIONS
SYSTEMS
270529 – HANGERS AND SUPPORTS
FOR COMMUNICATIONS SYSTEMS
ro d u ct D at a
L E
E D
S u b m it o p
D ra w in g s
S am p le s
S am p le s fo r In it ia l S el ec ti p le s fo r V er if ic at ri c
S am p le s fo r V er if ic at d eg at ed -D es ig n S u b m it ta l
P ro d u ct L is t
S U
B M
IT
T
A
270533 – CONDUITS AND BACKBOXS
FOR COMMUNICATIONS SYSTEMS
270536 – CABLE TRAYS FOR
COMMUNICATIONS SYSTEMS
270553 – IDENTIFICATION FOR
COMMUNICATIONS SYSTEMS
270637 – FIRESTOPPING FOR
COMMUNICATIONS SYSTEMS
270800 – TESTING OF
COMMUNICATIONS CABLING
271000 – STRUCTURED CABLING ✓ ✓ ✓
271116 – COMMUNICATIONS
CABINETS, RACKS, FRAMES AND
ENCLOSURES
271119 – COMMUNICATIONS
TERMINATIONS BLOCKS AND
PATCH PANELS
ro d u ct D at a
L E
E D
S u b m it o p
D ra w in g s
S am p le s
S am p le s fo r In it ia l S el ec ti p le s fo r V er if ic at ri c
S am p le s fo r V er if ic at d eg at ed -D es ig n S u b m it ta l
P ro d u ct L is t
S U
B M
IT
T
A
271123 – COMMUNICATIONS CABLE
MANAGEMENT AND LADDER RACK
271513 – COPPER HORIZONTAL
CABLING
271543 – COMMUNICATIONS
FACEPLATES AND CONNECTORS
271619 – COMMUNICATIONS PATCH
CORDS, STATION CORDS AND CROSS
CONNECT WIRE
275116 – PUBLIC ADDRESS SYSTEMS ✓ ✓ ✓
280000 – SECURITY
280500 – COMMON WORK RESULTS
FOR ELECTRONIC SAFETY AND
SECURITY
281300 – ACCESS CONTROL ✓ ✓ ✓
282300 – VIDEO SURVEILLANCE ✓ ✓ ✓
1.5 INFORMATIONAL SUBMITTALS
A. Qualification Data: For refrigerant recovery technician.
B. Proposed Protection Measures: Submit report, including Drawings, that indicates the measures proposed for protecting individuals and property, for environmental protection, for dust control and, for noise control. Indicate proposed locations and construction of barriers.
C. Schedule of Selective Demolition Activities: Indicate the following:
1. Detailed sequence of selective demolition and removal work, with starting and ending dates for each activity. Ensure Owner's building manager's and other tenants' on-site operations are uninterrupted.
2. Interruption of utility services. Indicate how long utility services will be interrupted.
3. Coordination for shutoff, capping, and continuation of utility services.
4. Use of elevator and stairs.
5. Coordination of Owner's continuing occupancy of portions of existing building and of Owner's partial occupancy of completed
Work.
D. Statement of Refrigerant Recovery: Signed by refrigerant recovery technician responsible for recovering refrigerant, stating that all refrigerant that was present was recovered and that recovery was performed according to EPA regulations. Include name and address of technician and date refrigerant was recovered.
E. Warranties: Documentation indicating that existing warranties are still in effect after completion of selective demolition.
1.6 CLOSEOUT SUBMITTALS
A. Inventory: Submit a list of items that have been removed and salvaged.
SECTION 030130 - MAINTENANCE OF CAST-IN-PLACE CONCRETE
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
1. Include construction details, material descriptions, chemical composition, physical properties, test data, and mixing, preparation, and application instructions.
B. Samples: Cured Samples for each exposed product and for each color and texture specified, in manufacturer's standard size appropriate for each type of work.
1.4 INFORMATIONAL SUBMITTALS
A. Qualification Data: For manufacturers.
B. Material Certificates: For each type of portland cement and aggregate supplied for mixing or adding to products at Project site.
C. Product Test Reports: For each manufactured bonding agent and cementitious patching mortar, for tests performed by manufacturer and witnessed by a qualified testing agency.
SECTION 035416 - HYDRAULIC CEMENT UNDERLAYMENT
A. Product Data: For each product indicated.
B. Shop Drawings: Include plans indicating substrates, locations, and average depths of underlayment based on survey of substrate conditions.
A. Qualification Data: For Installer.
SECTION 055000 - METAL FABRICATIONS
A. Product Data: For each product indicated.
B. Shop Drawings: Show fabrication and installation details. Include plans, elevations, sections, and details of metal fabrications and their connections. Show anchorage and accessory items. Provide Shop Drawings for the following:
1. Steel framing and supports for ceiling-hung toilet compartments.
2. Steel framing and supports for mechanical and electrical equipment.
3. Steel framing and supports for applications where framing and supports are not specified in other Sections.
C. Delegated-Design Submittal: For steel framing and supports for ceiling-hung toilet compartments and operable partitions, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation.
A. Qualification Data: For professional engineer's experience with providing delegated-design engineering services of the kind indicated, including documentation that engineer is licensed in the jurisdiction in which Project is located.
B. Welding certificates.
C. Research Reports: For post-installed anchors.
SECTION 057000 - DECORATIVE METAL
1.4 ACTION SUBMITTALS
A. Product Data: For each type of product, including finishing materials.
B. Shop Drawings: Show fabrication and installation details for decorative metal.
1. Include plans, elevations, component details, and attachment details.
2. Indicate materials and profiles of each decorative metal member, fittings, joinery, finishes, fasteners, anchorages, and accessory items.
C. Samples for Initial Selection: For products involving selection of color, texture, or design including mechanical finishes.
D. Samples for Verification: For each type of exposed finish.
1. Sections of linear shapes.
2. Samples of welded joints showing quality of workmanship and color matching of materials.
A. Qualification Data: For fabricator.
B. Welding certificates.
SECTION 057313 - GLAZED DECORATIVE METAL RAILINGS
1.5 ACTION SUBMITTALS
A. Product Data:
1. Metal railings assembled from standard components.
2. Glass products.
3. Glazing cement and accessories for structural glass railings.
4. Sealant and accessories for structural glass railings.
5. Fasteners.
6. Bituminous paint.
7. Nonshrink, nonmetallic grout.
B. Shop Drawings: Include plans, elevations, sections, and attachment details.
C. Samples for Initial Selection: For products involving selection of color, texture, or design.
D. Samples for Verification: For each type of exposed finish required.
1. Sections of each distinctly different linear railing member, including handrails, top rails, posts, and balusters.
2. Base channel.
3. Each type of glass and glass edge required.
4. Fittings and brackets.
5. Assembled Samples of railing systems, made from full-size components, including top rail, post, handrail, structural glass balusters . Show method of finishing members at intersections. Samples need not be full height.
E. Delegated-Design Submittal: For installed products indicated to comply with performance requirements and design criteria, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation.
1.6 INFORMATIONAL SUBMITTALS
A. Qualification Data: For Installer and professional engineer.
B. Product Test Reports: For tests performed by a qualified testing agency, in accordance with ASTM E894, ASTM E935, ASTM E2353, and ASTM E2358.
SECTION 061053 - MISCELLANEOUS ROUGH CARPENTRY
A. Product Data: For each type of process and factory-fabricated product. Indicate component materials and dimensions and include construction and application details.
1. Include data for fire-retardant treatment from chemical treatment manufacturer and certification by treating plant that treated materials comply with requirements. Include physical properties of treated materials based on testing by a qualified independent testing agency.
2. For fire-retardant treatments, include physical properties of treated lumber both before and after exposure to elevated temperatures, based on testing by a qualified independent testing agency according to ASTM D 5664.
A. Evaluation Reports: For the following, from ICC-ES:
1. Fire-retardant-treated wood.
2. Power-driven fasteners.
3. Post-installed anchors.
SECTION 064116 - PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
B. Shop Drawings:
1. Include plans, elevations, sections, and attachment details.
2. Show large-scale details.
3. Show locations and sizes of furring, blocking, and hanging strips, including concealed blocking and reinforcement specified in other Sections.
4. Show locations and sizes of cutouts and holes for items installed in plastic-laminate architectural cabinets.
C. Samples for Verification: For the following:
1. Plastic Laminates: 8 by 10 inches, for each type, color, pattern, and surface finish required.
a. Provide one sample applied to core material with specified edge material applied to one edge.
2. Thermoset Decorative Panels: 8 by 10 inches, for each color, pattern, and surface finish.
a. Provide edge banding on one edge.
3. Corner Pieces:
a. Cabinet-front frame joints between stiles and rails and at exposed end pieces, 18 inches high by 18 inches wide by 6 inches deep.
b. Miter joints for standing trim.
4. Exposed Cabinet Hardware and Accessories: One full-size unit for each type and finish.
A. Qualification Data: For manufacturer and Installer.
B. Product Certificates: For each type of product.
SECTION 064216 - FLUSH WOOD PANELING
A. Product Data: For each type of product.
1. Include data for fire-retardant treatment from chemical-treatment manufacturer and certification by treating plant that treated materials comply with requirements.
B. Shop Drawings: For flush wood paneling.
1. Include plans, elevations, sections, and attachment details.
2. Show details full size.
3. Show locations and sizes of furring and blocking, including concealed blocking specified in other Sections.
4. For paneling produced from premanufactured sets, show finished panel sizes, set numbers, sequence numbers within sets, and method of cutting panels to produce indicated sizes.
5. For paneling veneered in fabrication shop, show veneer leaves with dimensions, grain direction, exposed face, and identification numbers indicating the flitch and sequence within the flitch for each leaf.
6. Apply AWI Quality Certification Program label to Shop Drawings.
C. Samples: For each exposed product and for each color and finish specified, in manufacturer's or fabricator's standard size.
A. Qualification Data: For Installer and fabricator.
B. Product Certificates: For each type of product.
C. Quality Standard Compliance Certificates: AWI Quality Certification Program.
D. Evaluation Reports: For fire-retardant-treated materials, from ICC-ES.
SECTION 078413 - PENETRATION FIRESTOPPING
A. Product Data: For each type of through-penetration firestop system product indicated.
B. Shop Drawings: For each through-penetration firestop system, show each kind of construction condition penetrated, relationships to adjoining construction, and kind of penetrating item. Include firestop design designation of testing and inspecting agency acceptable to authorities having jurisdiction that evidences compliance with requirements for each condition indicated.
1. Submit documentation, including illustrations, from a qualified testing and inspecting agency that is applicable to each through-penetration firestop system configuration for construction and penetrating items.
2. Where Project conditions require modification of qualified testing and inspecting agency's illustration to suit a particular through-penetration firestop condition, submit illustration, with modifications marked, approved by through-penetration firestop system manufacturer's fire-protection engineer.
C. Product Schedule: For each penetration firestopping system. Include location and design designation of qualified testing and inspecting agency.
1. Where Project conditions require modification to a qualified testing and inspecting agency's illustration for a particular penetration firestopping condition, submit illustration, with modifications marked, approved by penetration firestopping manufacturer's fire-protection engineer as an engineering judgment or equivalent fire-resistance-rated assembly.
A. Qualification Data: For firms and persons specified in "Quality Assurance" Article to demonstrate their capabilities and experience.
Include lists of completed projects with project names and addresses, names and addresses of architects and owners, and other information specified.
B. Installer Certificates: From Installer indicating penetration firestopping has been installed in compliance with requirements and manufacturer's written recommendations.
C. Product Certificates: Signed by manufacturers of through-penetration firestop system products certifying that products furnished comply with requirements.
D. Product Test Reports: From a qualified testing agency indicating through-penetration firestop system complies with requirements, based on comprehensive testing of current products.
SECTION 078443 - JOINT FIRESTOPPING
A. Product Data: For each type of joint firestopping system product indicated.
B. Shop Drawings: For each joint firestopping system, show each kind of construction condition and relationships to adjoining construction. Include design designation of testing and inspecting agency acceptable to authorities having jurisdiction that evidences compliance with requirements for each condition indicated.
1. Submit documentation, including illustrations, from a qualified testing and inspecting agency that is applicable to each joint firestopping system configuration for construction and penetrating items.
2. Where Project conditions require modification of qualified testing and inspecting agency's illustration to suit a particular joint firestopping system condition, submit illustration, with modifications marked, approved by joint firestopping system manufacturer's fire-protection engineer.
C. Product Schedule: For each joint firestopping system. Include location and design designation of qualified testing agency.
1. Where Project conditions require modification to a qualified testing agency's illustration for a particular joint firestopping system condition, submit illustration, with modifications marked, approved by joint firestopping system manufacturer's fire-protection engineer as an engineering judgment or equivalent fire-resistance-rated assembly.
A. Qualification Data: For firms and persons specified in "Quality Assurance" Article to demonstrate their capabilities and experience.
Include lists of completed projects with project names and addresses, names and addresses of architects and owners, and other information specified.
B. Installer Certificates: From Installer indicating joint firestopping have been installed in compliance with requirements and manufacturer's written recommendations.
C. Product Certificates: Signed by manufacturers of joint firestopping system products certifying that products furnished comply with requirements.
D. Product Test Reports: From a qualified testing agency indicating fire resistant joint firestopping system complies with requirements, based on comprehensive testing of current products.
SECTION 079200 - JOINT SEALANTS
A. Product Data: For each joint-sealant product indicated.
B. Samples for Initial Selection: Manufacturer's color charts consisting of strips of cured sealants showing the full range of colors available for each product exposed to view.
C. Samples for Verification: For each kind and color of joint sealant required, provide Samples with joint sealants in 1/2-inch- wide joints formed between two 6-inch- long strips of material matching the appearance of exposed surfaces adjacent to joint sealants.
D. Joint-Sealant Schedule: Include the following information:
1. Joint-sealant application, joint location, and designation.
2. Joint-sealant manufacturer and product name.
3. Joint-sealant formulation.
4. Joint-sealant color.
A. Qualification Data: For qualified Installer and testing agency.
B. Product Certificates: For each kind of joint sealant and accessory, from manufacturer.
C. Sealant, Waterproofing, and Restoration Institute (SWRI) Validation Certificate: For each sealant specified to be validated by SWRI's Sealant Validation Program.
D. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, indicating that sealants comply with requirements.
E. Preconstruction Compatibility and Adhesion Test Reports: From sealant manufacturer, indicating the following:
1. Materials forming joint substrates and joint-sealant backings have been tested for compatibility and adhesion with joint sealants.
2. Interpretation of test results and written recommendations for primers and substrate preparation needed for adhesion.
F. Preconstruction Field-Adhesion Test Reports: Indicate which sealants and joint preparation methods resulted in optimum adhesion to joint substrates based on testing specified in "Preconstruction Testing" Article.
G. Field-Adhesion Test Reports: For each sealant application tested.
H. Warranties: Sample of special warranties.
SECTION 079219 - ACOUSTICAL JOINT SEALANTS
1.2 ACTION SUBMITTALS
A. Product Data: For each acoustical joint sealant.
B. Samples for Initial Selection: Manufacturer's color charts consisting of strips of cured sealants showing the full range of colors available for each product exposed to view.
C. Samples for Verification: For each kind and color of acoustical joint sealant required, provide Samples with joint sealants in 1/2-inch-wide joints formed between two 6-inch-long strips of material matching the appearance of exposed surfaces adjacent to joint sealants.
D. Acoustical-Joint-Sealant Schedule: Include the following information:
1. Joint-sealant application, joint location, and designation.
2. Joint-sealant manufacturer and product name.
3. Joint-sealant formulation.
4. Joint-sealant color.
1.3 INFORMATIONAL SUBMITTALS
A. Product Test Reports: For each kind of acoustical joint sealant, for tests performed by manufacturer and witnessed by a qualified testing agency.
B. Sample Warranties: For special warranties.
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES
A. Product Data: For each type of product.
1. Include construction details, material descriptions, core descriptions, fire-resistance ratings, and finishes.
B. Shop Drawings: Include the following:
1. Elevations of each door type.
2. Details of doors, including vertical- and horizontal-edge details and metal thicknesses.
3. Frame details for each frame type, including dimensioned profiles and metal thicknesses.
4. Locations of reinforcement and preparations for hardware.
5. Details of each different wall opening condition.
6. Details of electrical raceway and preparation for electrified hardware, access control systems, and security systems.
7. Details of anchorages, joints, field splices, and connections.
8. Details of accessories.
C. Samples for Initial Selection: For hollow-metal doors and frames with factory-applied color finishes.
D. Samples for Verification:
1. Finishes: For each type of exposed finish required, prepared on Samples of not less than 3 by 5 inches.
2. Fabrication: Prepare Samples approximately 12 by 12 inches to demonstrate compliance with requirements for quality of materials and construction:
a. Doors: Show vertical-edge, top, and bottom construction; core construction; and hinge and other applied hardware reinforcement. Include separate section showing glazing if applicable.
b. Frames: Show profile, corner joint, floor and wall anchors, and silencers. Include separate section showing fixed hollow-metal panels and glazing if applicable.
E. Product Schedule: For hollow-metal doors and frames, prepared by or under the supervision of supplier, using same reference numbers for details and openings as those on Drawings. Coordinate with final door hardware schedule.
A. Qualification Data: For door inspector.
1. Fire-Rated Door Inspector: Submit documentation of compliance with NFPA 80, Section 5.2.3.1.
B. Product Test Reports: For each type of fire-rated hollow-metal door and frame assembly for tests performed by a qualified testing agency indicating compliance with performance requirements.
C. Field quality control reports.
1.7 CLOSEOUT SUBMITTALS
A. Record Documents: For fire-rated doors, list of door numbers and applicable room name and number to which door accesses.
SECTION 081416 - FLUSH WOOD DOORS
A. Product Data: For each type of product, including the following:
1. Door core materials and construction.
2. Door edge construction.
3. Door face type and characteristics.
4. Door frame construction.
5. Factory-machining criteria.
6. Factory- finishing specifications.
B. Shop Drawings: Indicate location, size, and hand of each door; elevation of each type of door; construction details not covered in Product Data; and the following:
1. Door schedule indicating door location, type, size, fire protection rating, and swing.
2. Details of frame for each frame type, including dimensions and profile.
3. Details of electrical raceway and preparation for electrified hardware, access control systems, and security systems.
4. Dimensions and locations of blocking for hardware attachment.
5. Dimensions and locations of mortises and holes for hardware.
6. Clearances and undercuts.
7. Requirements for veneer matching.
8. Doors to be factory finished and application requirements.
C. Samples for Initial Selection: For factory-finished doors.
D. Samples for Verification:
1. Factory finishes applied to actual door face materials, approximately 8 by 10 inches, for each material and finish. For each wood species and transparent finish, provide set of three Samples showing typical range of color and grain to be expected in finished Work.
2. Corner sections of doors, approximately 8 by 10 inches, with door faces and edges representing actual materials to be used.
A. Qualification Data: For door inspector.
1. Fire-Rated Door Inspector: Submit documentation of compliance with NFPA 80, Section 5.2.3.1.
B. Sample Warranty: For special warranty.
1.5 CLOSEOUT SUBMITTALS
A. Special warranties.
B. Record Documents: For fire-rated doors, list of door numbers and applicable room name and number to which door accesses.
SECTION 083113 - ACCESS DOORS AND FRAMES
1. Include construction details, fire ratings, materials, individual components and profiles, and finishes.
B. Shop Drawings:
1. Include plans, elevations, sections, details, and attachments to other work.
2. Detail fabrication and installation of access doors and frames for each type of substrate.
C. Samples: For each door face material, at least 3 by 5 inches in size, in specified finish.
D. Product Schedule: Provide complete access door and frame schedule, including types, locations, sizes, latching or locking provisions, and other data pertinent to installation.
SECTION 084126.23 - INTERIOR ALL-GLASS ENTRANCES
A. Product Data: For each type of product.
1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for all-glass system.
B. Shop Drawings: For interior all-glass entrance systems.
1. Include plans, elevations, and sections.
2. Include details of fittings and glazing, including isometric drawings of fittings.
3. Include door hardware locations, mounting heights, and installation requirements.
C. Samples for Verification: For each type of exposed finish indicated, prepared on Samples of sizes indicated below:
1. Metal Finishes: 6-inch-long sections of fittings, and other items.
2. Glass: 6 inches square, showing exposed-edge finish.
3. Door Hardware: For exposed door hardware of each type, in specified finish, full size.
D. Fabrication Sample: Continuous rail fitting at bottom, made from 12-inch lengths of full-size components and showing details of the following:
1. Joinery.
2. Anchorage.
3. Glazing.
E. Door Hardware Schedule: Prepared by or under supervision of supplier, detailing fabrication and assembly of door hardware, as well as procedures and diagrams. Coordinate final door hardware schedule with door components, assemblies, and related work to ensure proper size, thickness, hand, function, and finish of door hardware.
A. Qualification Data:
1. For Installer.
B. Field quality-control reports.
C. Sample Warranty: For special warranty.
A. Maintenance Data: For interior all-glass entrance systems to include in maintenance manuals. Furnish a complete set of specialized tools and maintenance instructions as required for Owner's continued adjustment, maintenance, and removal and replacement of door hardware.
SECTION 08 71 00_Door_Hardware_2021-11-17
E. Informational Submittals:
1. Product Test Reports: Indicating compliance with cycle testing requirements, based on evaluation of comprehensive tests performed by manufacturer and witnessed by a qualified independent testing agency.
SECTION 088000 - GLAZING
A. Product Data: For each type of product.
B. Glass Samples: For each type of glass product other than clear monolithic vision glass; 12 inches square.
1. Laminated glass.
2. Insulating glass.
C. Glazing Schedule: List glass types and thicknesses for each size opening and location. Use same designations indicated on Drawings.
D. Delegated-Design Submittal: For glass indicated to comply with performance requirements and design criteria, including analysis data signed and sealed by qualified professional engineer responsible for their preparation.
A. Qualification Data: For Installer and manufacturers of fabricated glass units.
B. Product Certificates: For glass.
C. Product Test Reports: For fabricated glass, for tests performed by a qualified testing agency.
D. Preconstruction adhesion and compatibility test report.
E. Sample Warranties: For special warranties.
SECTION 088300 - MIRRORS
1. Mirrors. Include description of materials and process used to produce each type of silvered flat glass mirror specified that indicates sources of glass, glass coating components, edge sealer, and quality-control provisions.
B. Shop Drawings: Include mirror elevations, edge details, mirror hardware, and attachment details.
C. Samples: For each type of the following:
1. Mirrors: 12 inches square, including edge treatment on two adjoining edges.
2. Mirror Trim: 12 inches long.
B. Product Certificates: For each type of mirror and mirror mastic.
C. Preconstruction Test Reports: From mirror manufacturer indicating that mirror mastic was tested for compatibility and adhesion with mirror backing and substrates on which mirrors are installed.
D. Sample Warranty: For special warranty.
1.4 CLOSEOUT SUBMITTALS
A. Maintenance Data: For mirrors to include in maintenance manuals.
SECTION 088700 - GLAZING FILM
A. Product Data: Submit manufacturer's product specifications and installation instructions for type of material and application method required. Include certified test reports demonstrating that products comply with requirements.
B. Samples: Submit the following samples:
1. Two 12" x 12" samples of type of decorative glazing film required, adhered to a glass sample of the same type as to be used on the project.
2. One of such samples shall remain on the jobsite for use in comparing the approved appearance to that being installed.
A. Maintenance Data: Submit manufacturer's product maintenance and cleaning instructions.
SECTION 090190.52 - MAINTENANCE REPAINTING
A. Product Data: For each type of product.
1. Include recommendations for product application and use.
2. Include test data substantiating that products comply with requirements.
B. Samples: For each type of paint system and each pattern, color, and gloss; in sizes indicated below.
1. Include stepped Samples defining each separate coat, including fillers and primers. Resubmit until each required sheen, color, and texture is achieved.
2. For each painted color being matched to a standardized color-coding system, include the color chips from the color-coding-system company with Samples.
3. Include a list of materials for each coat of each Sample.
4. Label each Sample for location and application.
5. Sample Size:
a. Painted Surfaces: 4-by-8-inch Samples for each color and material, on hardboard.
C. Product List: For each paint product indicated, include the following:
1. Cross-reference to paint system and locations of application areas. Use same designations indicated on Drawings and in schedules.
A. Color Matching Certificate: For computer-matched colors.
B. Preconstruction Test Reports: For cleaning materials and paint removers.
SECTION 092216 - NON-STRUCTURAL METAL FRAMING
A. Product Certificates: For each type of code-compliance certification for studs and tracks.
B. Evaluation Reports: For embossed steel studs and tracks firestop tracks post-installed anchors and power-actuated fasteners, from ICC-ES or other qualified testing agency acceptable to authorities having jurisdiction.
SECTION 092900 - GYPSUM BOARD
A. Product Data: For each type of product.
B. Samples: For the following products:
1. Trim Accessories: Full-size Sample in 12-inch-long length for each trim accessory indicated.
SECTION 093013 - CERAMIC TILING
B. Shop Drawings: Show locations of each type of tile and tile pattern. Show widths, details, and locations of expansion, contraction, control, and isolation joints in tile substrates and finished tile surfaces.
C. Samples for Verification:
1. Full-size units of each type and composition of tile and for each color and finish required.
2. Full-size units of each type of trim and accessory for each color and finish required.
3. Stone thresholds in 6-inch lengths.
4. Metal edge strips in 6-inch lengths.
B. Master Grade Certificates: For each shipment, type, and composition of tile, signed by tile manufacturer and Installer.
C. Product Certificates: For each type of product.
D. Product Test Reports: For tile-setting and -grouting products and certified porcelain tile.
SECTION 095113 - ACOUSTICAL PANEL CEILINGS
B. Samples: For each exposed product and for each color and texture specified, 6 inches in size.
A. Coordination Drawings: Reflected ceiling plans, drawn to scale, on which the following items are shown and coordinated with each other, using input from installers of the items involved:
1. Ceiling suspension-system members.
2. Structural members to which suspension systems will be attached.
3. Method of attaching hangers to building structure.
4. Carrying channels or other supplemental support for hanger-wire attachment where conditions do not permit installation of hanger wires at required spacing.
5. Size and location of initial access modules for acoustical panels.
6. Items penetrating finished ceiling and ceiling-mounted items including the following:
a. Lighting fixtures.
b. Diffusers.
c. Grilles.
d. Speakers.
e. Sprinklers.
f. Access panels.
g. Perimeter moldings.
7. Show operation of hinged and sliding components covered by or adjacent to acoustical panels.
8. Minimum Drawing Scale: 1/4 inch = 1 foot.
B. Product Test Reports: For each acoustical panel ceiling, for tests performed by a qualified testing agency.
C. Evaluation Reports: For each acoustical panel ceiling suspension system and anchor and fastener type, from ICC-ES.
D. Field quality-control reports.
A. Maintenance Data: For finishes to include in maintenance manuals.
SECTION 095423 - LINEAR METAL CEILINGS
A. Product Data: For each type of product.
B. Shop Drawings: For linear metal ceilings.
1. Include reflected ceiling plans, sections, and details, drawn to scale, showing the following:
a. Linear ceiling patterns and joints.
b. Ceiling suspension members.
c. Method of attaching hangers to building structure and locations of cast-in-place anchors, clips, and other ceiling attachment devices whose installation is specified in other Sections.
d. Ceiling-mounted items including, but not limited to, light fixtures, diffusers, grilles, speakers, sprinklers, and access panels.
e. Ceiling perimeter and penetrations through ceiling; trim and moldings.
C. Samples: For each exposed product and for each type, color, and finish specified, 12 inches long in size.
D. Delegated Design Submittal: For design of attachment devices.
A. Qualification Data: For testing agency.
B. Product Test Reports: For each linear metal ceiling, for tests performed by a qualified testing agency.
C. Evaluation Reports: For linear-metal-ceiling framing systems.
D. Field quality-control reports.
A. Maintenance Data: For finishes to include in maintenance manuals.
SECTION 096513 - RESILIENT BASE AND ACCESSORIES
A. Product Data: For each type of product.
B. Samples: For each exposed product and for each color and texture specified, not less than 12 inches long.
C. Product Schedule: For resilient base and accessory products. Use same designations indicated on Drawings.
SECTION 096613 - PORTLAND CEMENT TERRAZZO FLOORING
A. Product Data: For each type of product.
B. Shop Drawings: Include terrazzo installation requirements. Include plans, sections, component details, and relationship to other work. Show layout of the following:
1. Divider strips.
2. Control-joint strips.
3. Accessory strips.
4. Terrazzo patterns.
C. Samples for Initial Selection: NTMA's "Terrazzo Color Palette" showing the full range of colors and patterns available for each terrazzo type.
D. Samples for Verification: For each type, material, color, and pattern of terrazzo and accessory required showing the full range of color, texture, and pattern variations expected. Label each terrazzo Sample to identify manufacturer's matrix color and aggregate types, sizes, and proportions. Prepare Samples of same thickness and from same material to be used for the Work, in sizes indicated below:
1. Terrazzo: 6-inch- square Samples.
2. Accessories: 6-inch- long Samples of each exposed strip item required.
B. Material Certificates: For each type of terrazzo material or product.
A. Maintenance Data: For terrazzo to include in maintenance manuals.
SECTION 096813 - TILE CARPETING
ACTION SUBMITTALS
Product Data: For each type of product.
Include manufacturer's written data on physical characteristics, durability, and fade resistance.
Include manufacturer's written installation recommendations for each type of substrate.
Shop Drawings: For carpet tile installation, plans showing the following:
Columns, doorways, enclosing walls or partitions, built-in cabinets, and locations where cutouts are required in carpet tiles.
Carpet tile type, color, and dye lot.
Type of subfloor.
Type of installation.
Pattern of installation.
Pattern type, location, and direction.
Pile direction.
Type, color, and location of insets and borders.
Type, color, and location of edge, transition, and other accessory strips.
Transition details to other flooring materials.
Samples for Verification: For each of the following products and for each color and texture required. Label each Sample with manufacturer's name, material description, color, pattern, and designation indicated on Drawings and in schedules.
Carpet Tile: Full-size Sample.
Exposed Edge, Transition, and Other Accessory Stripping: 12-inch-long Samples.
Product Schedule: For carpet tile. Use same designations indicated on Drawings.
INFORMATIONAL SUBMITTALS
Qualification Data: For Installer.
Sample Warranty: For special warranty.
CLOSEOUT SUBMITTALS
Maintenance Data: For carpet tiles to include in maintenance manuals. Include the following:
Methods for maintaining carpet tile, including cleaning and stain-removal products and procedures and manufacturer's recommended maintenance schedule.
Precautions for cleaning materials and methods that could be detrimental to carpet tile.
SECTION 098433 - SOUND-ABSORBING WALL UNITS
1. Include panel edge, core material, and mounting indicated.
B. Shop Drawings: For unit assembly and installation.
1. Include plans, elevations, sections, and mounting devices and details.
2. Include details at panel head, base, joints, and corners; and details at ceiling, floor base, and wall intersections. Indicate panel edge profile and core materials.
3. Include details at cutouts and penetrations for other work.
4. Include direction of fabric weave and pattern matching.
C. Samples for Initial Selection: For each type of fabric facing.
1. Include Samples of hardware and accessories involving color or finish selection.
D. Samples for Verification: For the following products:
1. Panel Edge: 12-inch-long Sample(s) showing each edge profile, corner, and finish.
2. Core Material: 12-inch-square Sample at corner.
3. Mounting Devices: Full-size Samples.
4. Assembled Panels: Approximately 36 by 36 inches, including joints and mounting methods.
A. Coordination Drawings: Elevations and other details, drawn to scale, on which the following items are shown and coordinated with each other, using input from installers of the items involved:
1. Electrical outlets, switches, and thermostats.
2. Items penetrating or covered by units including the following:
a. Lighting fixtures.
b. Air outlets and inlets.
c. Speakers.
d. Alarms.
e. Sprinklers.
f. Access panels.
3. Show operation of hinged and sliding components covered by or adjacent to units.
B. Product Certificates: For each type of unit.
C. Sample Warranty: For manufacturer's special warranty.
A. Maintenance Data: For each type of unit to include in maintenance manuals. Include fabric manufacturers' written cleaning and stain-removal instructions.
SECTION 099123 - INTERIOR PAINTNG
A. Product Data: For each type of product indicated.
B. Samples for Initial Selection: For each type of topcoat product indicated.
C. Samples for Verification: For each type of paint system and in each color and gloss of topcoat indicated.
1. Submit Samples on rigid backing, 8 inches square.
2. Step coats on Samples to show each coat required for system.
3. Label each coat of each Sample.
4. Label each Sample for location and application area.
D. Product List: For each product indicated, include the following:
1. Cross-reference to paint system and locations of application areas. Use same designations indicated on Drawings and in schedules.
2. Include color designations.
SECTION 101423.16 - ROOM-IDENTIFICATION PANEL SIGNAGE
1.2 INFORMATIONAL SUBMITTALS
A. Material Test Reports: For each concrete floor sealer.
B. Shop Drawings: For room-identification signs.
1. Include fabrication and installation details and attachments to other work.
2. Show sign mounting heights, locations of supplementary supports to be provided by other installers, and accessories.
3. Show message list, typestyles, graphic elements, including raised characters and Braille, and layout for each sign at least half size.
C. Samples for Initial Selection: For each type of sign assembly, exposed component, and exposed finish.
1. Include representative Samples of available typestyles and graphic symbols.
D. Samples for Verification: For each type of sign assembly showing all components and with the required finish(es), in manufacturer's standard size unless otherwise indicated and as follows:
1. Room-Identification Signs: Full-size Sample.
2. Exposed Accessories: Full-size Sample of each accessory type.
3. Full-size Samples, if approved, will be returned to Contractor for use in Project.
E. Product Schedule: For room-identification signs. Use same designations indicated on Drawings or specified.
A. Qualification Data: For Installer and manufacturer.
B. Sample Warranty: For special warranty.
1.7 CLOSEOUT SUBMITTALS
A. Maintenance Data: For signs to include in maintenance manuals.
SECTION 102113.17 - PHENOLIC-CORE TOILET COMPARTMENTS
A. Product Data: For each type of product.
1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for toilet compartments.
B. Shop Drawings: For toilet compartments.
1. Include plans, elevations, sections, details, and attachment details.
2. Show locations of cutouts for compartment-mounted toilet accessories.
3. Show locations of centerlines of toilet fixtures.
4. Show locations of floor drains.
5. Show ceiling grid, ceiling-mounted items, and overhead support or bracing locations.
C. Samples for Initial Selection: For each type of toilet compartment material indicated.
1. Include Samples of hardware and accessories involving material and color selection.
D. Samples for Verification: For the following products, in manufacturer's standard sizes unless otherwise indicated:
1. Each type of material, color, and finish required for toilet compartments, prepared on 6-inch-square Samples of same thickness and material indicated for Work.
2. Each type of hardware and accessory.
E. Product Schedule: For toilet compartments, prepared by or under the supervision of supplier, detailing location and selected colors for toilet compartment material.
A. Product Certificates: For each type of toilet compartment.
A. Maintenance Data: For toilet compartments to include in maintenance manuals.
SECTION 102219 - DEMOUNTABLE PARTITIONS
A. Product Data: For each type of product.
B. Shop Drawings: For demountable partitions.
1. Include plans, elevations, sections, and attachment details at floors, columns, permanent partitions, and ceilings; and method of erection and disassembly.
C. Samples for Verification: For each type of the following products:
1. Linear Trim: 12-inch-long Samples.
2. Glazing: Manufacturer's standard-size unit, but not less than 3 inches square.
3. Hardware and Accessories: Whole units.
A.…