CMF - SUBMITTAL REQUIREMENTS.pdf

PDF 465 KB Posted

Attached to
Malmstrom Air Force Base Sentinel Ground Based Strategic Deterrent (GBSD) Construction Projects
Solicitation number
W912DW_SentinelGBSD_NAICS236220
Issued by

About this file

This is a Sources Sought Submittal Form for a Consolidated Maintenance Facility (CMF) project at Malmstrom Air Force Base in Montana. The project involves constructing an approximately 181,000 square foot facility to support the Missile Maintenance Squadron and Sentinel mission, with an estimated construction cost between $250,000,000 and $500,000,000. The facility will include administrative offices, maintenance shops, drive-thru high bays with overhead cranes, vehicle exhaust systems, a vault, secure storage areas, loading dock, and shipping/receiving areas. The construction is classified under NAICS code 236220 with a small business size standard of $45,000,000, and the period of performance is anticipated to be 1,523 calendar days, with a construction award targeted for fiscal year 2027. The sources sought form requests potential contractors to provide project experience, business classification information, and bonding details, with a focus on demonstrating experience in missile maintenance facility construction and work on military installations.

View the file

Other files

File Type Posted
ITC - SUBMITTAL REQUIREMENTS.pdf PDF
ICC - SUBMITTAL REQUIREMENTS.pdf PDF
MHC - SUBMITTAL REQUIREMENTS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUMMARY DESCRIPTION OF PROPOSED PROJECT:

Consolidated Maintenance Facility (CMF) Construct a Consolidated Maintenance Facility (CMF) of approximately 181,000 SF to support the Missile Maintenance Squadron and Sentinel mission requirements at Malmstrom AFB, MT.

The CMF will provide administrative offices, maintenance shops, and drive-thru high bays with overhead cranes and vehicle exhaust systems to accommodate Transporter Erectors (TE), Payload Transporters (PT), and Missile Transporters (MT). Additional features include a vault, secure storage areas, a loading dock, and shipping/receiving areas with forklift maneuvering space.

Construction will consist of a deep reinforced concrete foundation (pier and grade beam), structural slab, structural steel framing, insulated metal panel exterior walls, interior masonry or metal stud partitions, and a sloped standing seam metal roof. Building systems will include electrical, mechanical, water, sewer, fire and lightning protection, security, NIPR and SIPR communications, and emergency power via a diesel generator with fuel storage and secondary containment.

Site development will include clearing, grading, drainage, utilities, communications connections, access paving, parking, walkways, and landscaping. The project scope also includes select demolition of existing facilities to support site development and utility tie-ins.

Period of Performance is anticipated to be approximately 1,523 calendar days, with a construction award targeted for fiscal year 2027.

NAICS CODE

The North American Industry Classification System (NAICS) code for this project is 236220, Commercial and Institutional Building Construction, and the associate small business size standard is $45,000,000.

MAGNITUDE

In accordance with DFARS 236.204, construction magnitude is estimated to be in the price range of between $250,000,000 and $500,000,000. 100 percent payment and performance bonds will be required of proposals, should a RFP be issued for this project.

CONSOLIDATED MAINTENANCE FACILITY (CMF)

SOURCES SOUGHT SUBMITTAL FORM

FIRM INFORMATION

1a. Firm Name:

1b. Firm Address: 1c. Unique Entity Identifier (UEI):

1d. Cage Code:

2a. Point of Contact (POC) Name & Title: 2b. POC Phone Number:

2c. POC Email Address:

3. Business Classification (indicate if SBA Certification) under the NAICS code 236220, Commercial and Institutional Building Construction.

Small Business Small Disadvantage Business (SDB) Woman-Owned SB (WOSB) Veteran-Owned SB (VOSB)

Service-Disabled VOSB (SDVOSB) Historically Underutilized Business Zone (HUBZone) 8(a) Program Other Than Small Business (Large Business)

SUBCONTRACTING INFORMATION

4. Of the total summary Description of Proposed Project:

a. Is your intention to pursue a Joint Venture or some other form of teaming arrangement to perform the work?

b. Please indicate: As a ___ large business / ___ small business, what estimated percentage of the

TOTAL project would you intend to self-perform? ____

c. Do you believe all aspects of the project could be performed by the small business sector?

d. Please specify/describe which areas are best suited for subcontracting to the small business sector:

e. Given your best estimate, what percentage of the total contract value could be subcontracted out to small businesses:

____ Small Business (SB)

____ Small Disadvantaged Business (SDB)

____ Woman-Owned Small Business (WOSB)

____ Veteran-Owned Small Business (VOSB)

____ Service-Disabled VOSB Business (SDVOSB)

____ Historically Underutilized Business Zone (HUBZone)

SOURCES SOUGHT SUBMITTAL FORM

PROJECT EXPERIENCE

5. Submit a maximum of three (3) examples of past projects. Contractor must provide a brief description of experience in performing similar projects for construction of similar size, complexity and scope completed within the last ten (10) years. Examples should include the following information:

a. Identify whether you were the Prime or Subcontractor

b. A description of the project features, complexities, start and end dates of construction, size of project, and dollar value of each project.

c. Demonstrated experience with the construction of missile maintenance facility of similar function, size, and complexity.

d. Statement if your projects were completed on time and within budge. If not, please provide explanation.

e. Demonstrated experience with construction projects on military installations.

f. Project References (including customer name, point of contact name/title, phone number and email address).

ATTACHMENTS

6. In addition to this form, and any project experience please submit the following attachments:

A. Response to #5 above. Narratives shall be no longer than 10 pages.

B. Bonding Information. (Please keep in mind the construction magnitude identified for each project). Provide bonding limits for on bonding company’s letterhead:

i) Single Bond; and ii)Aggregate bond

CONSOLIDATED MAINTENANCE FACILITY (CMF)

1a Firm Name:
1b Firm Address:
1c Unique Entity Identifier UEI 1d Cage Code:
2a Point of Contact POC Name Title:
2b POC Phone Number 2c POC Email Address:
undefined:
Small Business SB:
VeteranOwned Small Business VOSB:
Small Disadvantaged Business SDB:
ServiceDisabled VOSB Business SDVOSB:
WomanOwned Small Business WOSB:
Historically Underutilized Business Zone:
Dropdown1: [ ]
Dropdown2: [ ]
Text3:
Check Box4: Off
Text7:
Text8:
Check Box13: Off
Check Box14: Off
Check Box15: Off
Check Box16: Off
Check Box17: Off
Check Box18: Off
Check Box19: Off
Check Box20: Off

File details come from the government source that posted it. Updated .