CITY_24_2_(PW24_00009)_230 W SPALDING_STAMPED.pdf
PDF 24 MB Posted
- Solicitation number
- PE-66098-NONST-2025-000000066
- Issued by
- Fulton County, Georgia
About this file
This document appears to be a Request for Proposal (RFP) issued by the City for a construction project to install storm sewer infrastructure at 230 W Spalding. The project scope includes the installation of approximately 300 linear feet of storm sewer pipe, catch basins, and related site work. Responses to the RFP are due on March 15, 2023, with a mandatory pre-bid meeting scheduled for March 1, 2023. The contract is expected to be awarded on April 1, 2023, with a project duration of 120 calendar days from the notice to proceed.
The RFP includes specific pricing requirements, such as unit pricing for various bid items. No set-asides or incumbent information is provided. Funding for the project is through the City's capital improvement budget, but the exact amount is not disclosed. The RFP also contains standard legal terms and conditions typical of a public works contract.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ITB 25_017 Addendum.pdf | ||
| 25_017 230 West Spalding Drive Stormwater Imp.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET INDEX
SHEET NO. SHEET NAME
C0.00 COVER SHEET
C0.01 - C0.02 STANDARD SPECIFICATIONS
SURV BOUNDARY AND TOPOGRAPHIC SURVEY
C4.00 STORMWATER IMPROVEMENT PLAN
C6.10 EROSION CONTROL PLAN
C6.40 - C6.41 EROSION CONTROL DETAILS
C9.00 - C9.01 CONSTRUCTION DETAILS
230 WEST SPALDING DRIVE STORMWATER
IMPROVEMENTS
230 WEST SPALDING DRIVE
SANDY SPRINGS, GA 30328
FOR
CITY OF SANDY SPRINGS
1 GALAMBOS WAY
SANDY SPRINGS, GA 30328
PHONE: 770.730.5600
PREPARED BY:
CONTACT INFORMATION:
ENGINEER: NEIL SCHAAP, P.E.
PLANNERS AND ENGINEERS
COLLABORATIVE
ADDRESS: 350 RESEARCH COURT
PEACHTREE CORNERS,
GEORGIA 30092
PHONE: 770.451.2741
EMAIL: NSCHAAP@PEC.PLUS
OWNER: CITY OF SANDY SPRINGS
ADDRESS: 1 GALAMBOS WAY
SANDY SPRINGS, GA 30328
PHONE: 770.730.5600
1. TOTAL ONSITE AREA: 0.05 ACRES / TOTAL AREA DISTURBED 0.05 ACRES.
2. BOUNDARY & TOPOGRAPHIC INFORMATION PROVIDED BY GEOSURVEY, DATED 05/19/2023.
3. THE FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE RATE MAP FOR FULTON COUNTY COUNTY, GEORGIA AND INCORPORATED AREAS, COMMUNITY PANEL NUMBER(S) 13121C0134G, EFFECTIVE DATE 9/18/2013 WAS EXAMINED AND NO PORTION OF THE PROPERTY SHOWN HEREIN WAS FOUND TO FALL WITHIN A DESIGNATED FLOOD ZONE "A" (AREAS OF 100-YEAR FLOOD) OR SPECIAL FLOOD HAZARD ZONE (AREAS OF 500-YEAR FLOOD).
4. THERE ARE STATE WATERS LOCATED ON THE SITE.
5. THERE ARE NO KNOWN WETLANDS ON THIS SITE
6. THE ORTHOMETRIC HEIGHTS (ELEVATIONS AND CONTOURS) SHOWN HEREON WERE DETERMINED BY A COMBINATION
OF FIELD RUN SURVEY BY GEOSURVEY, DATED 05/19/2023 AND FULTON COUNTY COUNTY GIS.
24 HOUR CONTACT:
SANDY SPRINGS @ 770.730.5600
SITE AREA: SITE LOCATION MAP
NOT TO SCALE
FEMA FIRM MAP
FEMA FIRM PANEL NO.: 13121C0134G
NOT TO SCALE
0.05 AC
SITE INFORMATION
C0.00
COVER SHEET
N/A
Planners & Engineers Collaborative+
LAND PLANNING + LANDSCAPE ARCHITECTURE + CIVIL ENGINEERING
ARBORISTS + SURVEYING & CONSTRUCTION + WATER RESOURCES
350 RESEARCH COURT STE 200 PEACHTREE CORNERS, GA 30092 P: (770) 451-2741
23335.00 5/14/2024
2 3 4 5 6 7 8 9 10 11 12 13 14 151
K
J
I
H
G
F
E
D
C
B
A
2 3 4 5 6 7 8 9 10 11 12 13 14 151
SCALE:
DATE:
PROJECT:
DESCRIPTIONNO. BYDATE
GEORGIA WEST ZONE
GRID NORTH
SHEET
REVISIONS
c Th is d ra w in g is th e pr op er ty o f P la nn er s an d En gi ne er s
C ol la bo ra tiv e an d is n ot to b e co pi ed in w ho le o r i n pa rt.
It is n ot to b e us ed o n an y ot he r p ro je ct a nd is to b e re tu rn ed u po n re qu es t.
P la nn er s an d En gi ne er s
C ol la bo ra tiv e.
FOR
PROJECT
AT
J:
\2
3\
0\
D e\
_P la ns he et s\
C 0.
C O
V E
R S
H E
E T
- 2
.d w g
- N
S ch aa p
- 8 /3
0/
:5
A M
P: (770) 451-2741
350 RESEARCH COURT STE 200
PEACHTREE CORNERS, GA 30092
F: (770) 451-3915
WWW.PEC.PLUS
Planners & Engineers Collaborative+
LAND PLANNING
SURVEYING & CONSTRUCTION
CIVIL ENGINEERING
ARBORISTS
LANDSCAPE ARCHITECTURE
WATER RESOURCES+ +
CITY OF SANDY SPRINGS
1 GALAMBOS WAY
SANDY SPRINGS, GA 30328
P: 770.730.5600
230 WEST
SPALDING DRIVE
STORMWATER
IMPROVEMENTS
STORMWATER IMPROVEMENT
230 WEST SPALDING DRIVE
SANDY SPRINGS, GA 30328
THIS SEAL IS ONLY VALID IF COUNTER SIGNED
AND DATED WITH AN ORIGINAL SIGNATURE.
GSWCC LEVEL II DESIGN PROFESSIONAL
CERTIFICATION # 0000067548 EXP. 12/21/2024
8/30/2024
6/14/2024-1 NS PW REVIEW
6/19/2024-2 NS PW REVIEW
7/30/2024-3 NS CITY COMMENTS
8/30/2024-4 NS CITY COMMENTS
CONSTRUCTION SET
SITE LOCATION
SITE LOCATION
PROJECT SCOPE:
THIS PROJECT INVOLVES THE CENTRIFUGALLY CAST CONCRETE PIPE (CCCP) LINING OF 26 LF OF 48" CORRUGATED METAL PIPE (CMP) AS WELL AS 42 LF OF 54" CORRUGATED METAL PIPE. THE PROJECT ALSO INCLUDES REPLACEMENT OF THE UPSTREAM HEADWALL, REPLACING A DOUBLE WING CATCH BASIN TOP, REPAIRING 42 LF OF 5' WIDE SIDEWALK AND 40 LF OF CURB AND GUTTER.
CITY-24-2
ADDRESS: 230 WEST SPALDING DRIVE
SANDY SPRINGS, GA 30328
SITE DATA
N
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
10/12/2024
230 W SPALDING DR
CITY-24-2
Nataling Adkisson
C0.01
STANDARD
SPECIFICATIONS
N/A
GENERAL
1. ALL WORK TO BE DONE IN ACCORDANCE WITH THE GEORGIA DEPARTMENT OF
TRANSPORTATION STAND SPECIFICATIONS FOR THE CONSTRUCTION OF TRANSPORTATION
(GDOT) SYSTEMS, CURRENT EDITION, AND SUPPLEMENTS THERTO, AS APPROVED BY THE
FEDERAL HIGHWAY ADMINISTRATION.
2. ALL KNOWN UTILITY FACILITIES ARE SHOWN SCHEMATICALLY ON PLANS AND ARE NOT
NECESSARILY ACCURATE IN LOCATION AS TO PLAN OR ELEVATION. UTILITY FACILITIES SUCH AS
SERVICE LINES OR UNKNOWN FACILITIES NOT SHOWN ON PLANS WILL NOT RELIEVE THE
CONTRACTOR OF HIS OR HER RESPONSIBILITY UNDER THIS REQUIREMENT. "EXISTING UTILITY FACILITIES" MEANS ANY UTILITY THAT EXISTS ON THE PROJECT IN ITS ORIGINAL, RELOCATED OR
NEWLY INSTALLED POSITION. ALL SPECIFIC ITEMS IN THE DETAILED ESTIMATE ARE TO BE
REMOVED OR RELOCATED TO CLEAR CONSTRUCTION IN ADVANCE O F THE WORK. DISRUPTION
TO SERVICES OUTSIDE THE HOURS OF 9:00 AM AND 4:00 PM REQUIRE PRIOR APPROVAL BY THE
SANDY SPRINGS.
3. UTILITY WORK COORDINATION WILL BE REQUIRED AS PART OF THIS CONTRACT. THE
CONTRACTOR WILL BE REQUIRED TO USE THE ONE-CALL CENTER TELEPHONE NUMBER 811, FOR
THE PURPOSE OF COORDINATING THE MARKING OF UNDERGROUND UTILITIES. THE
CONTRACTOR'S ATTENTION IS CALL TO SUBSECTION 105.06 OF THE GDOT STANDARD
SPECIFICATIONS "COOPERATION WITH UTILITIES."
4. THE FOLLOWING UTILITIES HAVE FACILITIES IN THE PROJECT AREA:
ATLANTA GAS LIGHT (SOUTHERN COMPANY GAS)
CONTACT: GINNNY MAULDIN-KINNEY (404) 584-3176
FULTON COUNTY WATER AND SEWER SEWER
CONTACT: ABDUL AKBAR (404) 612-7518
GEORGIA POWER COMPANY
CONTACT: LAMONTE WASLIEN (404) 947-0729
AT&T
CONTACT: TIMOTHY MCCOY (770) 331-8689
5. THE TOTAL EARTHWORKS QUANTITY SHOWN ON THE PLANS FOR CLEARING AND GRUBBING IS
FOR INFORMATION ONLY. THE SANDY SPRINGS PUBLIC WORKS DEPARTMENT ASSUMES NO
RESPONSIBILITY FOR ITS ACCURACY, THE CONTRACTOR SHALL INCLUDE GRADING WORK AS
PART OF THE BID PRICE FOR GRADING COMPLETE AND IT SHALL BE HIS OR HER RESPONSIBILITY
TO DETERMINE THE ACTUAL EARTHWORK QUANTITY TO BE GRADED. NO CLAIMS WILL BE
CONSIDERED FOR EXTRA COMPENSATION IF THE CONTRACTOR RELIES ON THE QUANTITY
SHOWN ON THE PLANS. CLEARING AND GRUBBING ON THIS PROJECT IS LIMITED TO THE ACTUAL
CONSTRUCTION LIMITS UNLESS DIRECTED BY THE ENGINEER. COST FOR CLEARING AND
GRUBBING SHALL BE INCLUDED IN THE BID PRICE FOR GRADING COMPLETE.
6. THE CONTRACTOR SHALL STRICTLY ADHERE TO DUST CONTROL REGULATIONS. ALL AREAS
SUBJECTED TO DUST FORMATION MUST BE PERIODICALLY WATERED SUFFICIENT TO RETARD
DUST, NO SEPARATE PAYMENT WILL BE MADE FOR ANY COST INCURRED TO COMPLY WITH THIS
REQUIREMENT.
7. THE TOTAL AREA SHOWN ON THE PLANS FOR GRASSING IS FOR INFORMATION ONLY. THE SANDY
SPRINGS ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY. THE CONTRACTOR SHALL INCLUDE
IN THE BID PRICE FOR GRASSING, AND IT SHALL BE HIS RESPONSIBILITY TO DETERMINE THE
ACTUAL AREA TO BE GRASSED. NO CLAIMS WILL BE CONSIDERED FOR COMPENSATION IF THE
CONTRACTOR RELIES ON THE AREA SHOWN ON THE PLANS.
8. THE TYPE OF GRASS OR SOD USED ON THIS PROJECT WILL BE REQUIRED TO MATCH ANY TYPE
OF GRASS OR SOD WHICH MAY BE PLANTED AND GROWING ON THE ADJACENT LAW. I.E.
BERMUDA SOD FOR BERMUDA SOD, ZOYSIA FOR ZOYSIA, ETC. NO SEPARATE PAYMENT SHALL
BE MADE FOR ANY COST INCURRED TO COMPLY WITH THIS REQUIREMENT.
9. INGRESS AND EGRESS SHALL BE MAINTAINED AT ALL TIMES TO ADJACENT PROPERTIES. REFER
TO SUB-SECTION 107.07 OF THE GDOT STANDARD SPECIFICATIONS.
10. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FURNISH SUITABLE BORROW MATERIAL
FOR THE PROJECT AND DISPOSE OF ANY UNSUITABLE OR WASTE MATERIAL.
11. HORIZONTAL CONTROL IS BASED UPON GEORGIA STATE PLANE COORDINATE SYSTEM.
12. IN THE EVENT A DRIVEWAY IS DAMAGED DUE TO CONSTRUCTION, THE DRIVEWAY SHALL BE
REPLACED, IN KIND, I.E. ASPHALT FOR ASPHALT, CONCRETE FOR CONCRETE, AND BRICK
PAVERS FOR BRICK PAVERS. EXCEPT EARTH AND GRAVEL DRIVEWAYS SHALL BE REPLACED
WITH ASPHALT TO THE CONSTRUCTION LIMITS. DRIVEWAYS CONTAINING BRICK PAVERS SHALL
BE CONSTRUCTED USING GDOT SPECIFICATIONS. THE DRIVEWAY LOCATIONS INDICATED ON
THE PLANS ARE FROM THE BEST AVAILABLE DATA. THE CONTRACTOR SHALL CONSTRUCT NEW
DRIVEWAYS TO MATCH ACTUAL FIELD LOCATIONS OF EXISTING DRIVEWAYS WHERE THEY ARE
NOT IN CONFLICT WITH RULES AND REGULATIONS. THE CONTRACTOR SHALL OBTAIN THE
APPROVAL OF THE ENGINEER PRIOR TO MAKING ANY REVISIONS SUCH AS TO LOCATION, WIDTH
AND/OR NUMBER OF DRIVES TO BE CONSTRUCTED. WHERE REQUIRED, THE DRIVEWAY SHALL BE
PAVED AS FOLLOWS:
ASPHALTIC DRIVES
RESIDENTIAL:
1.5" RECY. ASPHALTIC CONCRETE, 9.5mm SUPERPAVE, GP 2 ONLY, INCLUDING BITUM. MAT'L & H. LIME
6" GRADED AGGREGATE BASE
COMMERCIAL:
1.5" RECY. ASPHALTIC CONCRETE, 9.5mm SUPERPAVE, GP 2 ONLY, INCLUDING BITUM. MAT'L AND H. LIME
2" RECY. ASPHALTIC CONC. 19mm SUPERPAVE, GP 1 OR 2, INCLUDING BITUM. MAT'L AND H.LIME
8" GRADED AGGREGATE BASE
CONCRETE DRIVES
RESIDENTIAL: 6" CONCRETE VALLEY GUTTER
6" CONCRETE DRIVEWAY
COMMERCIAL: 8" CONCRETE VALLEY GUTTER
8" CONCRETE DRIVEWAY
ALL DRIVEWAYS SHALL BE PAVED TO THE LIMITS OF CONSTRUCTION. EXISTING
DRIVEWAYS SHALL NOT BE USED FOR PROJECT ACCESS.
13. WHERE WET SUBGRADE IS ENCOUNTERED AND WATER IDENTIFIED BY THE ENGINEER, AN
UNDERDRAIN PIPE WITH DRAINAGE AGGREGATE SHALL BE PLACED AS DIRECTED BY THE
ENGINEER TO AID IN DEWATERING THE SUBGRADE.
14. THE CONTRACTOR SHALL OBSERVE ALL APPLICABLE LOCAL, STATE, AND FEDERAL SAFETY
REGULATIONS REGARDING PIPE INSTALLATION IN TRENCHES. NO SEPARATE PAYMENT WILL BE
MADE FOR ANY COST INCURRED TO COMPLY WITH THIS REQUIREMENT.
15. ALL EXISTING STORMWATER PIPE SHALL BE REMOVED UNLESS OTHERWISE NOTED ON PLANS OR AS DIRECTED BY THE ENGINEER. ALL COST FOR REMOVAL SHALL BE INCLUDED IN THE LUMP
SUM BID PRICE FOR GRADING COMPLETE.
16. IN AREAS WHERE TYPE 2 CURB IS USED, DRAINAGE STRUCTURES 1033D AND 1034D WILL BE
REQUIRED. IN AREAS WHERE TYPE 7 CURB IS USED, DRAINAGE STRUCTURES 1033G AD 1034G
WILL BE REQUIRED.
17. AT LOCATIONS WHERE NEW PAVEMENT IS TO BE PLACED ADJACENT TO EXISTING PAVEMENT
WITHOUT AN OVERLAY OR WHERE CURBING IS TO BE PLACED ACROSS A PAVED AREA, A JOINT
SHALL BE SAWED ON A LINE ESTABLISHED BY THE ENGINEER TO ENSURE PAVEMENT REMOVAL
TO A NEAT LINE. THE COST FOR ASPHALT SAWED JOINTS, WHEN REQUIRED, SHALL BE INCLUDED
IN THE BID PRICE FOR GRADING COMPLETE.
18. WHERE EXISTING PAVEMENT MARKINGS AND LINES ARE IN CONFLICT WITH THE TRAFFIC
PATTERN BEING USED ON CONSTRUCTION, THE THE CONTRACTOR SHALL REMOVE OR OVERLAY
LINES TO THE SATISFACTION OF THE ENGINEER SUCH THAT THE LINES DO NOT CONFUSE THE
TRAVELING PUBLIC. ALL REMAINING LINES OR MARKINGS SHALL BE IN ACCORDANCE WITH THE
'MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES', OR AS DIRECTED BY THE ENGINEER.
TRAFFIC SHALL NOT BE ALLOWED ON ANY PAVEMENT NOT PROPERLY STRIPED.
19. THE CONTRACTOR'S ATTENTION IS DIRECTED TO ARTICLES 104.05 AND 107.07 OF THE STANDARD
SPECIFICATIONS AND THE SPECIAL PROVISIONS FOR TRAFFIC CONTROL AND SEQUENCE OF
OPERATIONS IN REGARDS TO MAINTENANCE OF TRAFFIC DURING CONSTRUCTION.
20. THE BID PRICE FOR TRAFFIC CONTROL SHALL INCLUDE, BUT IS NOT LIMITED TO CONSTRUCTION, MAINTENANCE , AND REMOVAL OF TEMPORARY SIGNAGE AND PAVEMENT MARKINGS, BARRICADES, CHANNELIZING DEVICES, ETC, REQUIRED FOR MAINTENANCE OF TRAFFIC DURING
CONSTRUCTION. ALL TEMPORARY SIGNAGE AND PAVEMENT MARKINGS SHALL BE IN
ACCORDANCE WIT THE 'MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES', CURRENT EDITION
AND/OR AS DIRECTED BY THE ENGINEER.
21. ALL CUT AND FILL SLOPES SHALL BE GRASSED AS DIRECTED BY THE ENGINEER IMMEDIATELY
AFTER THE SLOPES ARE ESTABLISHED IN ORDER TO REDUCE EROSION. IF THE SEASON DOES
NOT PERMIT GRASSING, TEMPORARY MULCH SHALL BE USED AS DIRECTED BY THE ENGINEER.
22. THE CONTRACTOR SHALL ENSURE THAT POSITIVE AND ADEQUATE DRAINAGE IS MAINTAINED AT
ALL TIMES WITHIN THE PROJECT LIMITS. THIS MAY INCLUDE, BUT NOT LIMITED TO,
REPLACEMENT OR RECONSTRUCTION OF EXISTING DRAINAGE STRUCTURES THAT HAVE BEEN
DAMAGED, REMOVED OR REGRADED AS REQUIRED BY THE ENGINEER, EXCEPT FOR THOSE
DRAINAGE ITEMS SHOWN AT SPECIFIC LOCATIONS ON THE PLANS. NO SEPARATE PAYMENT WILL
BE MADE FOR ANY COSTS INCURRED TO COMPLY WITH THIS REQUIREMENT.
23. QUANTITIES SHOWN ON THE PLANS ARE FOR ESTIMATION PURPOSES ONLY. CONTRACTOR IS TO
VERIFY ALL QUANTITIES TO BE INCLUDED IN THE BID PRICE.
24. EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO OR CONCURRENT WITH LAND
DISTURBANCE ACTIVITIES AND SHALL BE MAINTAINED AT ALL TIMES. ADDITIONAL EROSION AND
SEDIMENT CONTROL DEVICES SHALL BE INSTALLED IF DEEMED NECESSARY BY THE ON-SITE
INSPECTOR OR AS DIRECTED BY THE ENGINEER.
25. ALL SILT FENCES MUST BE PLACED AS ACCESS IS OBTAINED DURING CLEARING. NO GRADING
SHALL BE DONE UNTIL SILT FENCE INSTALLATION IS COMPLETE. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO MAINTAIN ALL SILT FENCES AND TO REPAIR OR REPLACE ANY SILT FENCE
THAT IS NOT SATISFACTORY. EROSION CONTROL MEASURES SHALL BE PLACED IMMEDIATELY
AFTER DRAINAGE STRUCTURES ARE IN PLACE. ALL EROSION CONTROL DEVICES SHALL BE
PLACED ACCORDING TO THE PLANS AND AS DIRECTED BY THE ENGINEER. SEE THE GEORGIA
STANDARD SPECIFICATIONS AND THE 'MANUAL FOR EROSION AND SEDIMENT CONTROL IN
GEORGIA', CURRENT EDITION REGARDING EROSION CONTROL. THE CONTRACTOR SHALL BE
RESPONSIBLE TO KEEP WETLAND AREAS FREE FROM SILTATION. THE CONTRACTOR SHALL
OBTAIN AND ABIDE BY ALL UNITED STATES ARMY CORPS OF ENGINEERS (USACE) RULES AND
REGULATIONS CONCERNING CONSTRUCTION ADJACENT TO WATERS OF THE UNITED STATES
(WOTUS) AND MAINTAIN WATER QUALITY.
26. THIS PROJECT HAS A TOTAL DISTURBED AREA OF 0.05 ACRES. THE DISTURBED AREA
ENCOMPASSES THE THE AREA ASSOCIATED WITH CLEARING, GRADING, EXCAVATING, FILLING
OF LAND, OR OTHER SIMILAR ACTIVITIES WHICH MAY RESULT IN SOIL EROSION, AS DEFINED
UNDER 'CONSTRUCTION ACTIVITIES' IN THE STATE OF GEORGIA NATURAL POLLUTANT
DISCHARGE ELIMINATION SYSTEM (NPDES) GENERAL PERMIT NO. GAR100002.
27. AGGREGATE SURFACE COURSE FOR TEMPORARY, DRIVEWAYS, INCLUDING MATERIAL, HAUL
AND PLACEMENT SHALL BE USED AT THE ENGINEER'S DIRECTION TO FACILITATE THE
MOVEMENT OF LOCAL TRAFFIC THROUGH THE CONSTRUCTION AREA DURING INCLEMENT
WEATHER. WHEN USED FOR THIS PURPOSE, SECTION 318 OF THE GDOT STANDARD
SPECIFICATIONS IS MODIFIED TO PERMIT TRUCK DUMPING ON UNPREPARED WET, MUDDY
SUBGRADE. SECTION 318 IS FURTHER MODIFIED TO PERT THE USE OF CRUSHER STONE AS
DESCRIBED IN SECTION 318.02.
28. THE CONTRACTOR WILL HAVE THE USE OF THE FOLLOWING MATERIALS:
A. GRADED AGGREGATE, ARTICLE 815.2.01
B. COURSE GRADED AGGREGATE, SIZE 467, ARTICLE 800.2.01
C. STABILIZED AGGREGATE, TYPE I OR II, SECTION 803.2 OR 803.2.02
D. CRUSHED STONE, ARTICLE 806.2.01
29. CONSTRUCTION LAYOUT AND STAGING PLAN WILL BE REQUIRED BY THE CONTRACTOR. ALL
COST FOR THIS ITEM WILL BE INCLUDED IN THE BID PRICE.
30. SANDY SPRINGS PUBLIC WORKS DEPARTMENT SHALL BE NOTIFIED A MINIMUM OF 72 HOURS IN
ADVANCE OF ALL CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL COORDINATE THIS
ACTION WITH THE LEAD INSPECTOR.
31. THE GDOT STANDARDS AND CONSTRUCTION DETAILS REQUIRED FOR THIS PROJECT ARE LISTED IN THIS PLAN SET WITH THE LAST KNOWN REVISION DATE, HOWEVER THE CONTRACTOR WILL BE
RESPONSIBLE FOR OBTAINING AND MAINTAINING ON THE PROJECT SITE THE CURRENT GDOT
STANDARD DRAWINGS AND CONSTRUCTION DETAILS REQUIRED FOR THIS PROJECT.
32. ANY ADJUSTMENTS OR RELOCATIONS OF SANDY SPRINGS PUBLIC WORKS DEPARTMENT
FACILITIES SHALL BE IN ACCORDANCE WITH THE SANDY SPRINGS ORDINANCE NUMBER
2008-09-48. THIS DOCUMENT IS AVAILABLE AT THE DEPARTMENT OFFICE AT 1 GALAMBOS WAY, SANDY SPRINGS. TELEPHONE 770.730.5600 AND THE 24 HR EMERGENCY CONTACT NUMBER FOR
THE CITY OF SANDY SPRINGS IS 770.730.5600.
33. THE SURVEY FOR THIS PROJECT WAS PREPARED BY GEOSURVEY AND SUPPLEMENTED USING
FULTON COUNTY AND CITY OF SANDY SPRINGS GIS DATA.
34. STORM DRAINAGE FOR THE ROADWAY MUST BE MAINTAINED DURING CONSTRUCTION.
35. UNLESS OTHERWISE SPECIFIED, ANY IRRIGATION SYSTEM ENCOUNTERED WITHIN THE LIMITS OF
CONSTRUCTION IS TO BE RE-ESTABLISHED (INCLUDING TESTING) BY THE CONTRACTOR.
PROJECT CONTRACTOR IS TO CUT AND CAP IRRIGATION SYSTEM OUTSIDE OF LIMITS OF
CONSTRUCTION DURING CONSTRUCTION.
36. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY DEBRIS REMAINING AFTER THE REMOVAL OF
OF THE EXISTING STORM SEWER PIPES/STRUCTURES AND OTHER DELETERIOUS NON-SOIL
MATERIALS SHOULD BE STRIPPED FROM PROPOSED CONSTRICTION AREAS.
37. EXCAVATION BRACING (SHORING) DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE
GENERAL CONTRACTOR. ANY SHORING (INCLUDING TRENCH BOXES) GREATER THAN FOUR (4)
FEET MUST BE SIGNED AND SEALED BY A STRUCTURAL ENGINEER CURRENTLY REGISTERED IN
THE STATE OF GEORGIA.
38. FILL MATERIAL SHOULD BE LOW PLASTICITY SOIL (PLASTICITY INDEX LESS THAN 30), FREE OF
NON-SOIL MATERIALS AND ROCK FRAGMENTS LARGER THAN 2 INCHES IN ANY ONE DIMENSION.
39. SOIL MOISTURE CONTENT SHOULD BE MAINTAINED WITHIN 3% OF THE OPTIMUM MOISTURE
CONTENT.
40. ORGANIC AND/OR DEBRIS LADEN MATERIAL (>3% ORGANICS BY WEIGHT) IS NOT SUITABLE FOR
RE-USE AS STRUCTURAL FILL.
41. FILL SHOULD BE PLACED IN THIN, HORIZONTAL LOOSE LIFTS (MAXIMUM 8-INCH) AND COMPACTED
TO AT LEAST 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698). THE
UPPER 8 INCHES OF SOIL BENEATH PAVEMENTS SHOULD BE COMPACTED TO AT LEAST 98%
STANDARD PROCTOR.
42. CONTRACTOR SHALL PROVIDE INDEPENDENT GEOTECHNICAL TESTING TO VERIFY SOIL
COMPACTION MEETS THE SANDY SPRINGS STANDARDS.
43. FILL MATERIALS USED IN STRUCTURAL AREAS SHOULD HAVE A TARGET MAXIMUM DRY DENSITY
OF AT LEAST 95 POUNDS PER CUBIC FOOT (PCF).
44. OPEN-GRADED CRUSHED STONE SHOULD BE PLACED IN RELATIVELY THIN LIFTS OF 12 INCHES
OR LESS AND COMPACTED WITH VIBRATORY COMPACTION EQUIPMENT.
45. WATER LEVELS SHALL BE MAINTAINED AT LEAST ONE FOOT BELOW WORKING SUBGRADE
SURFACES TO AVOID DEGRADING SUBGRADE.
46. THE SUBGRADE SHOULD BE WELL-DRAINED TO PREVENT THE ACCUMULATION OF WATER.
47. GRADING COMPLETE - LUMP SUM SHALL INCLUDE ALL UNCLASSIFIED EXCAVATION, BORROW
EXCAVATION, CHANNEL EXCAVATION, FOUNDATION BACKFILL MATERIAL, TYPE I, ROCK
EXCAVATION, ASPHALT CUTS, CLEARING AND GRUBBING, TREE REMOVAL, DEBRIS/SOLD WASTE
REMOVAL, AND REMOVAL OF ALL ITEMS NOT SHOWN AS SEPARATE PAY ITEM. THIS SHALL ALSO
INCLUDE ALL COMPACTION EFFORTS NECESSARY TO ACHIEVE THE COMPACTION REQUIREMENT
SPECIFIED IN THE PLANS.
48. SITE CONTRACTOR SHALL FURNISH "AS-BUILT" DRAWINGS INDICATING ALL CHANGES AND
DEVIATIONS FROM CONTRACT DRAWINGS THAT ARE SIGNED AND SEALED BY A REGISTERED
LAND SURVEYOR (R.L.S.).
49. GATE VALVES SHALL CONFORM TO AWWA C500 (LATEST EDITION) FOR DOUBLE DISC GATE
VALVES, OR AWWA C509 (LATEST EDITION) FOR RESILIENT-SEATED GATE VALVES, AND SHALL BE
AS MANUFACTURED BY AMERICAN FLOW CONTROL, U.S. PIPE, MUELLER, CLOW, OR APPROVED
EQUAL.GATE VALVES SHALL BE HAND-OPERATED, NON-RISING STEM, WITH CAST OR DUCTILE
IRON BODIES, AND ADAPTED FOR JOINTS AS INDICATED IN THE APPROVED DESIGN DRAWINGS, OR AS DIRECTED. BOLTING MATERIALS OF THE VALVE SHALL ONLY BE ZINC-COATED (HOT DIP) IN
ACCORDANCE WITH ASTM A153, CLASS C AND D, COATED THICKNESS GRADE OR STAINLESS
STEEL 304 (THE LATTER SHALL BE USED ONLY IF NO GALVANIC CORROSION IS PROMOTED). ALL
GATE VALVES SHALL OPEN BY TURNING THE OPERATING NUT TO THE LEFT
(COUNTER-CLOCKWISE). GATE VALVES SHALL ONLY BE USED IN SIZES OF TWO (2) INCHES
THROUGH TEN (10) INCHES. GREATER THAN TEN (10) INCHES MAY BE PERMITTED IF USING
RESILIENT SEATED GATE VALVES. THE VALVE ENDS SHALL BE WITH MECHANICAL JOINTS.
FASTENERS SHALL BE AS SPECIFIED UNDER 50) BELOW. TORQUE VALUES FOR THE BOLTS SHALL
BE AS PRESCRIBED BY THE VALVE MANUFACTURER AND IN COMBINATION WITH THE SPECIFIC
GASKETS THAT ARE USED. ALL BURIED NUTS AND BOLTS SHALL BE WRAPPED WITH DENSO
PROFILING MASTIC AND WRAPPED IN POLYETHYLENE SHEETING WITH A MINIMUM THICKNESS OF
84 MILS.
50. ALL MECHANICAL JOINT DIP SHALL BE MANUFACTURED IN ACCORDANCE WITH AND MEETING THE LATEST REQUIREMENTS OF AWWA C151/A21.51. THE MECHANICAL JOINT HEREIN SPECIFIED
FOR MECHANICAL JOINT DIP AND FITTINGS SHALL MEET THE LATEST REQUIREMENTS OF AWWA
C110/A21.10 WITH JOINTS MEETING THE LATEST REQUIREMENTS OF AWWA C111/A21.11. ALL
NUTS, BOLTS, AND WASHERS SHALL BE IN ACCORDANCE WITH ASME/ANSI B1.1, UNIFIED INCH
SCREW THREADS, CLASS 2A, EXTERNAL AND CLASS B, INTERNAL, LOW-CARBON STEEL
CONFORMING TO AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) A307 (60,000 PSI
TENSILE STRENGTH). CORROSION PROTECTION OF THE FASTENERS SHALL BE ZINCCOATED
(HOT DIP) IN ACCORDANCE WITH ASTM A153, CLASS C AND D, COATED THICKNESS GRADE. ALL BURIED NUTS AND BOLTS SHALL BE WRAPPED WITH DENSO PROFILING MASTIC AND WRAPPED IN
POLYETHYLENE SHEETING WITH A MINIMUM THICKNESS 84 MILS.
DRAWING LEGEND
EXISTING CONTOURS
PROPOSED CONTOURS
PROPOSED WATER LINE
PROPOSED WATER METER
PROPOSED VALVE & END CAP
PROPOSED FIRE HYDRANT & FDC
PROPOSED TEE, BEND & INTERSECTION
PROPOSED SANITARY SEWER LINE
PROPOSED SANITARY MANHOLE
PROPOSED SANITARY CLEANOUT
PROPOSED GREASE TRAP
PROPOSED STORM LINE
PROPOSED JUNCTION BOX
PROPOSED DROP INLET
PROPOSED YARD INLET
PROPOSED CURB INLET
PROPOSED WEIR INLET
PROPOSED CATCH BASIN
PROPOSED HEADWALL
PROPOSED OUTLET CONTROL STRUCTURE
W
23335.00 5/14/2024
2 3 4 5 6 7 8 9 10 11 12 13 14 151
K
J
I
H
G
F
E
D
C
B
A
2 3 4 5 6 7 8 9 10 11 12 13 14 151
SCALE:
DATE:
PROJECT:
DESCRIPTIONNO. BYDATE
GEORGIA WEST ZONE
GRID NORTH
SHEET
REVISIONS
c Th is d ra w in g is th e pr op er ty o f P la nn er s an d En gi ne er s
C ol la bo ra tiv e an d is n ot to b e co pi ed in w ho le o r i n pa rt.
It is n ot to b e us ed o n an y ot he r p ro je ct a nd is to b e re tu rn ed u po n re qu nn er s an d En gi ne er s
C ol la bo ra tiv e.
FOR
PROJECT
AT
J:
\2
3\
0\
D e\
_P la ns he et s\
C 0.
C O
V E
R S
H E
E T
- 2
.d w g
- N
S ch aa p
- 7 /3
0/
1:
A M
P: (770) 451-2741
350 RESEARCH COURT STE 200
PEACHTREE CORNERS, GA 30092
F: (770) 451-3915
WWW.PEC.PLUS
Planners & Engineers Collaborative+
LAND PLANNING
SURVEYING & CONSTRUCTION
CIVIL ENGINEERING
ARBORISTS
LANDSCAPE ARCHITECTURE
WATER RESOURCES+ +
CITY OF SANDY SPRINGS
1 GALAMBOS WAY
SANDY SPRINGS, GA 30328
P: 770.730.5600
230 WEST
SPALDING DRIVE
STORMWATER
IMPROVEMENTS
STORMWATER IMPROVEMENT
230 WEST SPALDING DRIVE
SANDY SPRINGS, GA 30328
THIS SEAL IS ONLY VALID IF COUNTER SIGNED
AND DATED WITH AN ORIGINAL SIGNATURE.
GSWCC LEVEL II DESIGN PROFESSIONAL
CERTIFICATION # 0000067548 EXP. 12/21/2024
7/30/2024
6/14/2024-1 NS PW REVIEW
6/19/2024-2 NS PW REVIEW
7/30/2024-3 NS CITY COMMENTS
ALL WORK SHALL BE DONE IN ACCORDANCE WITH GEORGIA
DEPARTMENT OF TRANSPORTATION STANDARD
SPECIFICATIONS CONSTRUCTION OF TRANSPORTATION
SYSTEMS, APPROVED APRIL 18, 2013; AND GDOT
CONSTRUCTIONS STANDARDS AND DETAILS, LATEST VERSIONS.
SPECIFICATIONS USED ARE NOT LIMITED TO THE
SPECIFICATIONS LISTED ON THE FOLLOWING PAGES.
GDOT DETAILS USED IN PROJECT
GDOT DETAIL NUMBER GDOT DETAIL TITLE
9032B CONCRETE CURB & GUTTER, CONCRETE
CURBS, CONCRETE MEDIANS
1034D CATCH BASINS
1001B CONCRETE HEADWALL
CENTRIFUGALLY CAST CONCRETE PIPE INSTALLATION
TO FOLLOW THE NATIONAL ASSOCIATION OF SEWER
SERVICE COMPANIES (NASSCO) PERFORMANCE
SPECIFICATION GUIDELINE (PSG), LATEST EDITION
2009.
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
10/12/2024
230 W SPALDING DR
C0.02
STANDARD
SPECIFICATIONS
N/A
23335.00 5/14/2024
2 3 4 5 6 7 8 9 10 11 12 13 14 151
K
J
I
H
G
F
E
D
C
B
A
2 3 4 5 6 7 8 9 10 11 12 13 14 151
SCALE:
DATE:
PROJECT:
DESCRIPTIONNO. BYDATE
GEORGIA WEST ZONE
GRID NORTH
SHEET
REVISIONS
c Th is d ra w in g is th e pr op er ty o f P la nn er s an d En gi ne er s
C ol la bo ra tiv e an d is n ot to b e co pi ed in w ho le o r i n pa rt.
It is n ot to b e us ed o n an y ot he r p ro je ct a nd is to b e re tu rn ed u po n re qu nn er s an d En gi ne er s
C ol la bo ra tiv e.
FOR
PROJECT
AT
J:
\2
3\
0\
D e\
_P la ns he et s\
C 0.
C O
V E
R S
H E
E T
- 2
.d w g
- N
S ch aa p
- 7 /3
0/
1:
A M
P: (770) 451-2741
350 RESEARCH COURT STE 200
PEACHTREE CORNERS, GA 30092
F: (770) 451-3915
WWW.PEC.PLUS
Planners & Engineers Collaborative+
LAND PLANNING
SURVEYING & CONSTRUCTION
CIVIL ENGINEERING
ARBORISTS
LANDSCAPE ARCHITECTURE
WATER RESOURCES+ +
CITY OF SANDY SPRINGS
1 GALAMBOS WAY
SANDY SPRINGS, GA 30328
P: 770.730.5600
230 WEST
SPALDING DRIVE
STORMWATER
IMPROVEMENTS
STORMWATER IMPROVEMENT
230 WEST SPALDING DRIVE
SANDY SPRINGS, GA 30328
THIS SEAL IS ONLY VALID IF COUNTER SIGNED
AND DATED WITH AN ORIGINAL SIGNATURE.
GSWCC LEVEL II DESIGN PROFESSIONAL
CERTIFICATION # 0000067548 EXP. 12/21/2024
7/30/2024
6/14/2024-1 NS PW REVIEW
6/19/2024-2 NS PW REVIEW
7/30/2024-3 NS CITY COMMENTS
4.4 POST-INSTALLATION INSPECTION AND TESTING REQUIREMENTS
1. After all liner installation and lateral connection work has been completed, the contractor shall inspect via CCTV all new CCCP within 3 weeks of installation completion. Inspection of pipelines shall be performed by NASSCO PACP certified, experienced personnel, trained in locating breaks, obstacles, and service connections using CCTV inspection techniques. For every segment of CCCP installed, the
2. Contractor shall generate a report that documents the installation including date, time, temperature, curing temperature, curing time, of applied material type and volume. The reports shall be submitted along with the post-installation CCTV inspection to the Engineer prior to acceptance of work and submittal of payment request.
3. There shall be no dry spots, lifts, ridges, splits, cracks, uncured mortar, delaminations or other defects in the CCCP. There shall be no visible infiltration through the liner or from behind the liner at manholes and service connections. Defects in the finished liner that cause backwater, reduce the pipe’s hydraulic capacity or structural stability or that create voids between the liner and pipe wall will be unacceptable.
Defective lining will be repaired to design specifications at no additional cost.
4. Thickness verification can be done with mass balance calculations where you calculate the amount of material that went in over the surface area to get an average depth.
5. Indicator tabs can be attached on the piping to verify the proper thickness is achieved. These are positioned to be just below the specified thickness and are left in place when sprayed over.
6. In addition, the engineer may request at his/her discretion the contractor to remove a test core(s) from the installed liner at specified location(s) at the Contractors’ expense. The Contractor shall mark the core samples with the date that the liner was installed and the date that the core was removed and the location taken. When requested by the engineer, the liner shall be cored at three different clock positions, and the average thickness measured shall be taking as the actual thickness of the liner. If a sample is not within 90% of the specified minimum thickness and or 90% of the 28-day compressive strength, the liner is considered unacceptable. Submit a proposed method of repair or replacement for review and approval by the engineer. Work required to remedy nonconforming work shall be at no additional cost.
7. Installed CCCP that does not meet the specified strength and / or thickness requirements, regardless of the deviation from these specified requirements, shall be corrected by the Contractor in a manner approved by the Engineer. Options for correcting deficient liner installations that will be considered by the Engineer include removal of the existing liner and re-lining the pipe or complete replacement of the storm drainage pipe.
PART 5 - MEASUREMENT
1. The quantity of Centrifugally Cast Pipe Liner to be paid for will be the actual number of linear feet of pipe liner, which has been installed and accepted. Measurement will be made horizontally along the centerline of the installed liner defined as the distance between the upstream and downstream structures using applicable structure inside walls as the beginning and ending point. Measurement from center of structure to center of structure will not be permitted. Measurement will not be made across drainage structures.
2. Invert Mortar Repair will be measured and paid in cubic yards, which has been incorporated into the completed and accepted work in accordance with the special provisions.
PART 6 - WARRANTY
1. Furnish one-year manufacturer's warranty for liner.
CENTRIFUGALLY CAST CONCRETE PIPE (CCCP) LINING AND INVERT MORTAR REPAIR SPECIFICATIONS
PART 1 - GENERAL
1.1 SUMMARY
1. Work covered by this specification includes providing all labor, materials, equipment, and incidentals required to clean/prepare existing storm sewer pipe, repair invert, install and test Centrifugally Cast Concrete Pipe (CCCP) Liner as shown on the Drawings and specified herein. CCCP is a geopolymer or cementitious mortar liner material that may be applied to existing concrete and corrugated metal storm sewer pipe. The CCCP shall be abrasion and corrosion resistant material, tight-fitting against the existing pipe, continuous, waterproof, and structurally reinforced fully deteriorated pipe.
2. All products supplied and all work performed shall be in accordance with The Facility Owner's Standard Specifications, applicable standards from American Society for Testing and Material American Water Works Association (AWWA), American National Standards Institute GDOT Utility Accommodation Policy and Standards, and the Georgia Environmental Protection Division (EPD) Guidelines for Sewage Collection Systems. Latest revisions of all standards shall apply.
3. Related Requirements:
1. GDOT Specification 660 - Sanitary Sewers
Special Provision Section 660 (dated 11/13/14 or most recent version)
2. GDOT Specification 936 - CCTV
1.2 UNIT PRICE - MEASUREMENT AND PAYMENT
CIPP Pipe Lining:
1. Basis of Measurement: By linear foot, measured from center of manhole to center of manhole.
2. Basis of Payment: Includes pipe cleaning and flushing, pre- and post- TV inspection and videography, liner installation, water for inversion, disposal of water, pipe gaskets (end seals), testing of liner, and cure tracking technology as specified below.
PART 2 - MATERIALS
2.1 REFERENCE STANDARDS
1. ASTM C39 – Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens.
2. ASTM C78 – Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point
Loading). (Note: ASTM C293 – Standard Test method for Flexural Strength of Concrete (Using Simple Beam With Center-Point Loading) – Is not a substitute test for the more conservative ASTM C78, ASTM C293 provides flexural strengths significantly higher than ASTM C78 due to relaxed loading conditions which are not appropriate for this type of structural repair).
3. ASTM C109 – Standard Test method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in Cube Specimens).
4. ASTM C157 – Modified Standard Test Method for Length Change of Hardened Hydraulic Cement Mortar and Concrete
5. ASTM C309 – Standard Specification for Liquid Membrane-Forming Compounds for Curing Concrete
6. ASTM C469 – Standard Test Method for Static Modulus of Elasticity and Poisson’s Ratio of Concrete in
Compression.
7. ASTM C496 – Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens.
8. ASTM C666 – Standard Test Method for Resistance of Concrete to Rapid Freezing and Thawing.
9. ASTM C882 (Type II or Type V) – Standard Test Method for Bond Strength of Epoxy-Resin Systems Used with Concrete By Slant Shear.
9. ASTM C1090 – Standard Test Method for measuring Changes in Height of Cylindrical Specimens of
Hydraulic-Cement Grout.
10. ASTM D4541 – Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers
11. ASTM F1216 – Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and
Curing of a Resin Impregnated Tube
12. ACI 229 – Controlled Low Strength Materials
2.2 LINER
1. The liner shall be applied by centrifugally spin-casting or hand-sprayed.
2. The liner shall be capable of fitting into irregularly shaped pipe sections and through bends and dips within the pipeline. The wall color of the interior pipe surface of CCCP after installation shall be a relatively light reflective color so that a clear detailed examination with closed circuit television inspection equipment may be performed.
3. The liner shall be chemically resistant to chemicals found in stormwater runoff; such as but not limited to gasoline, oil products, grass clippings, and fertilizers.
4. When cured the liner shall form a continuous, tight-fitting, watertight and impermeable liner.
5. Existing pipe conditions shall be reflected in the design of the liner thickness. In particular, the ovality of the existing pipe and, thus, the liner pipe shall be accurately estimated and reflected in the design calculations.
6. The thickness of the liner shall be the largest thickness as determined by calculations for deflection, bending, buckling, and minimum stiffness. Minimum liner thickens shall be 1/2-inch.
2.3 PROPERTIES
The CCCP shall conform to the following properties under laboratory conditions:
Property/Test Method Duration Results Compressive Strength 1 Day Min. 2,500 psi ASTM C-39/C-109 28 Days Min. 8,000 psi
Flexural Strength 7 Day 750 psi ASTM C-787 28 Days 1,500 psi
Modulus of Elasticity 1 Day 3,000,000 psi ASTM C-469 28 Days 5,000,000 psi
Bond Strength to Concrete 1 Day Min. 900 psi ASTM C-882 28 Days Min. 2,500 psi
Set Time 70°F (Geopolymer) Initial Set 60-75 Minutes ASTM C-807 Initial Cure Time Final Set 90-110 Minutes
Set Time 70°F (Cementitious) Initial Set Approx. 150 Minutes ASTM C-403 Initial Cure Time Final Set Approx. 300 Minutes
Freeze Thaw Durability 300 Cycles 100% ASTM C-666 Zero Loss
Shrinkage 28 Days 0.00% @ 65% R.H.
ASTM C-1090
Tensile Strength 28 Days Min. 800 psi
ASTM C-496
2.4. INVERT REPAIR MORTAR:
Abrasion and corrosion resistant mortar, based on advanced cements and additives including rust inhibitors. When mixed with the appropriate amount of water, a self-consolidating free flowing material will develop with high 24-hour compressive strength and adhesion.
PART 3 - SUBMITTALS
The Contractor shall submit for review and approval by the Engineer the following information, fifteen (15) business days prior to beginning work on the site:
1. Shop drawings of all CCCP materials. Shop drawings shall be prepared by a Georgia Registered Professional Engineer. The following supplemental information shall also be included:
a. Product MSDS sheets and manufacturers shipping, handling, and storage recommendations.
2. Certified test report from a Testing Laboratory or Manufacturer, that the CCCP material was manufactured and tested in accordance with all ASTM standards specified and referenced herein.
3. Engineering calculations specifying the design and required thickness (no less than 1/2"-inch) for each segment of CCCP installation, which are signed and sealed by a Georgia Registered Professional Engineer. The CCCP shall be designed to the following minimum criteria:
a. All sections of pipe shall be considered fully deteriorated.
b. All pipes shall be subjected to soil loads of 120 pounds per cubic foot.
c. The soil modulus shall be no more than 1,000 psi.
d. All pipes located shall be assumed to carry AASHTO HS20-44 live loads
e. The contractor shall assume a factor of safety of 2.0.
f. Ground water is assumed 3 feet below surface elevation, unless site-specific data is available.
e. The depth of cover as shown on plans.
f. CCCP design life 50 years or greater.
g. Hydraulic Capacity – Overall, the hydraulic cross-section shall be maintained as large as possible. The CCCP shall have a Manning’s “n” value of 0.013 or less after installation.
4. Health and Safety Plan, including confined space safety plan.
5. Emergency Response Plan. The Contractor shall include a plan to address reported backups or other problems resulting from the work, including personnel contact, equipment, disposal, etc.
The minimum response time to address any issues shall be two hours unless otherwise directed by the Engineer.
6. Maintenance of Base Flows plan. The plan shall include but not be limited to pump sizes, capacity, power requirements, pump selection and other calculations, pump curves, and piping sizes and locations. Bypass pumping systems shall include as a minimum one or more pumps capable of handling the base flow and storm events without the stored water level exceeding the crown of the pipe and one standby pump equal to the largest pump used.
7. Identification of water source(s) that will be used during CCCP installation. Contractor is responsible for securing and providing the necessary water for curing the CCCP. Contractor shall coordinate with the City of Atlanta if proposed water is obtained from fire hydrants. The Contractor is responsible for obtaining permits from Atlanta Water for water and sewer usage.
8. Identification of staging area(s) necessary for CCCP installation.
9. Contractor shall provide a hard copy summary of all inspections performed, defining all pipe sections inspected, measured lengths to features (pipe penetrations, structures, damage, etc.), and inspection date.
An electronic copy of the inspection report, inspection still images, the pipe inspection video files, and inspection database shall be provided.
PART 4 - CONSTRUCTION METHODS
4.1 SITE PREPARATION
1. The Contractor shall verify site conditions prior to commencing any construction activities. Site conditions include, but are not limited to, inlet and access port accessibility, accessibility to remote locations and encroachment onto private or publicly owned property. Selection of inspection equipment shall be based on the conditions of the storm drainage piping, structures, and inlets at the time the work commences. All dimensions shall be field verified by the Contractor.
2. The Contractor shall clean existing pipes of debris, sedimentation, and mineral deposits with high-velocity cleaner, bucket scraper, root saws, rolling or balling units, or other appropriate means.
3. The Contractor shall conduct a NASSCO PACP compliant color digital television inspection of each length of pipe prior to ordering liner. The purpose of this inspection is to confirm that existing conditions are suitable for the installation of the proposed lining process, to document the location of all service lateral connections and to confirm point repair locations. Digital recordings shall be prepared and retained by the Contractor and submitted with the post-lining inspection recordings prior to request for payment. Where this television inspection reveals conditions that are not suitable for lining, the digital recordings shall be immediately provided to the Engineer for review.
4. The Contractor shall protect the storm drainage system and adjacent properties from damage that might result from construction. Any damage caused by the Contractor’s operations shall be repaired to the complete satisfaction of the Engineer at no additional cost.
5. Protruding lateral connections, if encountered, shall be cut or ground with a robotic cutter flush with the pipe to be lined prior to liner installation. All lateral connections for reconnection after CCCP installation shall be documented. The cutting operation shall be monitored by CCTV equipment to verify proper execution of work. Cutter shall be capable of cutting the following materials: vitrified clay pipe, polyvinyl chloride pipe, ductile iron pipe, high-density polyethylene pipe, or reinforced concrete pipe.
Equipment specifically designed for cutting roots from storm drainage pipes (such as a chain cutter) shall not be allowed for this purpose.
6. If, in the opinion of the CCCP manufacturer, the rate of infiltration in the storm drainage pipe presents washout risk of the applied material, then the Contractor shall perform measures as required to minimize infiltration prior to lining. Any infiltration gusher identified shall be brought to the attention of the Engineer. The Contractor shall submit for approval to the Engineer the measures to prevent any adverse issues to the installation of the final product. The submittals shall be reviewed and approved prior to installation.
4.2 DELIVERY, HANDLING AND INSTALLATION
1. Normal precautions for “nuisance dust” shall be observed. Consult manufacturer’s Material Safety Data Sheet for details. The Contractor shall install liner in strict accordance with applicable OSHA standards.
The bypass pump(s) shall be setup and ready for immediate operation. Pumps shall be automatically controlled. The Contractor shall properly maintain the bypass pumping system. A responsible operator shall be on site at all times during bypass pumping operations. Drainage flows from existing storm drainage pipes shall not be allowed to enter the rehabilitated facilities until those facilities have been cleaned and CCCP completely installed including curing.
3. Contractor shall reopen all existing lateral connections in each length of pipe following liner installation.
Lateral connections shall be determined from the pre-installation CCTV inspection. The lateral connections shall be reopened from inside the pipe by means of a television camera controlled cutting device appropriate for the liner material and the pipe. All pipe connections shall be completely opened, clean and neatly cut, shall be flush with the lateral pipe and the cut shall be wire polished. The bottom of the opening shall be flush with the bottom of the lateral pipe so that there is not a lip. All liner penetrations shall be watertight. The Contractor shall be fully responsible for all backups and damage caused by unopened or not fully opening lateral connections, including paying all costs associated with repairing damage as required by the Engineer, Owner and/or property owner.
4. Contractor shall, with approval from Fulton County, discharge all water used for cooling, heating, and curing to the existing sanitary sewer system. Contractor may utilize a vacuum truck to remove the water from the site and discharge directly to a wastewater treatment plant. No water used for the installation of the CCCP shall be discharged into the downstream storm drainage system.
4.3 HOT AND COLD WEATHER APPLICATIONS
1. Apply liner material during suitable ambient temperatures per manufacturer’s recommendations. Liner shall be protected in hot (above 80°F and rising) and cold temperatures (below 45°F and falling).
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
10/12/2024
230 W SPALDING DR
PRAVIN D RATNAM
STACY & ROBERT VOUTILADONALD & NANCY GOSNELL
TIM
OTHY & JA
NE VAUGHAN
TYLER J BLUME
KRISTINA L WILSON
DOUGLAS & MARY HORNNICOLE RENEE CAMY &
CALVIN C SMITH
SARA E COOK &
GeoSurvey
W. Spalding Drive Storm System
GeoSurvey
Know what's below.
before you dig.Call Dial 811
Or Call 800-282-7411
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
10/12/2024
230 W SPALDING DR
CITY-24-2
Nataling Adkisson http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com http://www.geosurvey.com
4+00
4+18
0+
1+
1+
8" DIP
30" CMP
54" C M
P
" C
M P
2:1
4:1
DONALD & NANCY GOSNELL
TIM
OTHY &
JA
NE VAUGHAN
TYLER J BLUME
SARA E COOK &
EXISTING STONE HW (AGM_19554) TO BE
REPLACED WITH GDOT 1001B PRECAST
HEADWALL (45° WING WALLS) WITH STONE
VENEER (SEE DETAIL).
GRADE SIDE SLOPES AT
1.5H:1V. STABILIZE WITH
WOVEN GEOTEXTILE
EXISTING CITY OF ATLANTA 10" DIP WATER LINE
THROUGH CROWN OF PIPE. NOT TO BE DISTURBED.
EDGE OF 5' WIDE SIDEWALK
REPLACEMENT
TYPE 2 CURB AND GUTTER
REPLACEMENT (40 LF +/-)
5' WIDE CONCRETE SIDEWALK
REPLACEMENT (45 LF +/-)
42 LF (+/-) 54" CMP INSIDE WALL
TO BE SPIN-CAST LINED (CCCP)
SEAL ALL CONNECTIONS BETWEEN
DWCB AND STORM PIPES WITH
NON-SHRINK GROUT. REPAIR INVERT. EXISTING 6" CMP LATERAL TAP.
ORIGIN UNKNOWN. CONTRACTOR TO
FILL PIPE (AND VOIDS) WITH GROUT
AND ABANDON IN PLACE
PERMANENT DRAINAGE
EASEMENT
TEMPORARY CONSTRUCTION
EASEMENT
LO
D
/ TPF
LO
D
/ TPF
LO
D
/ TPF
LOD / TPF
LOD / TPF
LOD / TPF
LOD / TPF
LO
D
/ TPF
LO
D
/ TPF
LO
D
/ TPF LOD
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LO
D
TP
F
TPF
TPF
TPF
TPF TPF
TP
F
TPF
TPF
TREE PROTECTION FENCE
26 LF (+/-) 48" CMP INSIDE WALL
TO BE SPIN-CAST LINED (CCCP)
SEAL ALL CONNECTIONS BETWEEN
DWCB AND STORM PIPES WITH
NON-SHRINK GROUT. REPAIR INVERT.
PRESSURE GROUT SINKHOLE AROUND 48"
CMP. BACKFILL WITH SUITABLE SOIL AND
COMPACTION. WATER LINE NOT TO BE
DISTURBED.
REPLACE DWCB TOP (IMS_1923). NEW GDOT 1034D
TOP RAISED TO RIM ELEVATION 923.97
TYPE 2 CURB AND GUTTER REPLACEMENT
EXISTING WOOD POWER POLE TO
REMAIN. CONTRACTOR TO COORDINATE
WITH GA POWER AS NEEDED
CIPP LINING ONLY
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
0+00
9.
9.
0+50
3.
3.
1+00
3.
3.
1+50
5.
5.
1+50
5.
5.
IN
V
O U
T:
7.
(2
IN
V
IN
:9
.2
(4
(B
IN
V
IN
:9
.2
(E
X
" C M
P
IN
LE
T
D W
C B
(IM
S_
ST
A:
0+
.5
R
IM
: 9
.6
IN
V
O U
T:
6.
(1
IN
V
IN
:9
.4
(2
D W
C B
(IM
S_
ST
A:
0+
.5
R
IM
: 9
.8
2 ~ 54" CMP
41.96 LF ~ 1.67%
1 ~ 54" CMP
25.74 LF ~ 2.72%
IN
V
O U
T:
7.
(E X
" C
M P
IN
LE
T
H W
(A G
M _1
ST
A:
0+
.2
R
IM
: 9
.7
EX 48" CMP INLET ~ 48" CMP
25.34 LF ~ 1.97%
IN
V
IN
:9
.4
(1
H W
(A G
M _1
ST
A:
1+
.2
R
IM
: 9
.4
EX. CROSSING 8" SANITARY DIP INVERT: 914.68'
EXISTING 10" DIP WATER LINE (OUTSIDE TO BE SPIN
CAST LINED AND ENCASED AFTER CURING)
EXISTING GRADE
EXISTING 25-YR HGL
PROPOSED 25-YR HGL
26 LF OF 48" CMP TO BE LINED
(CCCP)
42 LF OF 54" CMP TO BE LINED (CCCP)
EXISTING STONE HW (AGM)19554) TO BE REPLACED
WITH GDOT 1001B PRECAST HEADWALL WITH
STONE VENEER (SEE DETAIL).
REPLACE DWCB TOP (IMS_1923). NEW TOP RAISED
TO RIM ELEVATION 923.97
PR
O
PO
SE
D R
IM
: 9
.9
REPOUR SIDEWALK TO GRADE. PRESSURE GROUT
EXISTING VOID BEHIND DWCB (IMS_1923)
EXISTING 6" CMP LATERAL TAP. FILL PIPE (AND VOIDS)
WITH GROUT AND ABANDON IN PLACE.
SEAL ALL PIPE CONNECTIONS
WITH NON-SHRINK GROUT
AND REPAIR INVERT.
SEAL ALL PIPE CONNECTIONS WITH
NON-SHRINK GROUT AND REPAIR INVERT.
EXISTING CONCRETE
CHANNEL
UTILITY NOTES:
1. ALL WORK AND MATERIALS SHALL COMPLY WITH THE CITY OF SANDY SPRINGS,
GEORGIA REGULATIONS AND CODES AND O.S.H.A. STANDARDS.
2. EXISTING STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE ABANDONED
REMOVED, OR RELOCATED AS NECESSARY.
3. MINIMUM 2' COVER OVER ALL PIPES IN NON-TRAFFIC AREAS. 3' MINIMUM COVER
UNDER PAVEMENT AND TRAFFIC AREAS.
4. BEDDING, FITTINGS, AND CONNECTIONS SHALL BE INSTALLED PER
MANUFACTURER'S SPECIFICATIONS.
5. COMPACTION EQUIPMENT TO BE USED ON ALL PIPES AND SERVICES UNDER
PAVEMENT.
6. TAPE AND WIRE ALL PLASTIC PIPES AND SERVICES.
7. DEVELOPER SHALL INSTALL "DRAINS TO WATERWAY" STICKER ON ALL CATCH
BASINS.
8. ALL WATER VALVES TO BE THE SAME SIZE AS INDICATED WATER LINES.
9. CLEAN-OUTS WILL BE PROVIDED AT ALL TURNING POINTS ON LATERAL LINES.
HEADWALL VENEER:
1. CONTRACTOR TO PROVIDE SUBMITTALS ON STONE VENEER TO THE CITY FOR
APPROVAL. VENEER TO ATTACHED TO HEADWALL BASED ON DETAILS SHOWN ON
C9.00 (OR MANUFACTURER'S RECOMMENDATIONS).
CCCP LINING NOTE:
PIPE TO BE THOROUGHLY CLEANED AND INSPECTED PRIOR TO LINING. VOIDS UNDER PIPE
TO BE FILLED WITH INJECTION GROUTING. SEE CCCP SPECIFICATIONS ON C0.02
PROJECT SCOPE:
1. REPLACEMENT OF EXISTING STONE HEADWALL LOCATED BETWEEN 230 AND 240
WEST SPALDING DRIVE.
2. REPLACE DWCB TOP WITH GDOT 1034D.
3. REFURBISHING CURB, GUTTER, AND SIDEWALK RESULTING FROM INLET
RENOVATION.
4. CIPP LINING 48" AND 54" CMP UNDER WEST SPALDING DRIVE.
5. ASSOCIATED EROSION AND SEDIMENT CONTROL MEASURES.
IRRIGATION:
1. DRAWINGS DO NOT GUARANTEE THE LOCATION OR ABSENCE OF IRRIGATION LINES.
SEE NOTE #35 ON SHEET C0.01.
R
Knowwhat'sbelow.
Callbefore you dig.
www.Georgia811.com
C4.00
STORMWATER
IMPROVEMENT PLAN
1" = 10'
5 10 20 300
23335.00 5/14/2024
2 3 4 5 6 7 8 9 10 11 12 13…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .