Circuit Parameters and Testing Requirements

VENDOR MUST PROVIDE LIGHT LEVEL READINGS (DB LOSS) ON EXTENSION FROM COMMERCIAL POP TO GOVERNMENT SERVICE DELIVERY POINT (SDP) AT THE "Z" LOCATION PRIOR TO CIRCUIT TURN UP TO THE GOVERNMENT ENSURING LEVELS ARE WITHIN SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -3 TO - 9.

VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO INSTALLATION AT THE "Z" LOCATION

ONLY.

VENDOR MUST CONTACT DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP UPON RECEIPT OF A VALID (TSO) TO ESTABLISH THE COORDINATION AND ACTIVATION PROCESS. (C) 618-220- 8627 (D) 770-8627

PROVIDER MUST CONDUCT A SATISFACTORY 24-HOUR TEST FROM THE DROP SIDE OF THEIR OR LOCAL EXCHANGE CARRIERS FDP INSTALLED IN THEIR EQUIPMENT SUITE AT THE "A" LOCATION TO THE

GOVERNMENT'S SDP AT THE "Z" LOCATION AND MUST INCLUDE THE EXTENSION BETWEEN THE

COMMERCIAL DEMARC AND THE GOVERNMENT'S SDP AT THE "Z" LOCATION.

VENDOR MUST ENSURE A TEST SET IS PLACED AT THE DROP SIDE OF TELECOMM PROVIDER'S OR LOCAL ACCESS PROVIDERS FDP AS APPLICABLE AT THE "A" LOCATION AND A SECOND TEST SET AT THE END OF THE FIBER JUMPERS TO BE USED FOR TERMINATION TO THE GOVERNMENT'S SDP AT THE "Z" LOCATION.

TESTING MUST BE SATISFACTORY PRIOR TO TURN OVER TO THE GOVERNMENT FOR ACCEPTANCE

TESTING.

TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564 BENCH MARKING

CONFIGURATION AND PERFORMANCE OF ETHERNET SERVICE. NOTE-ETHERNET FRAME SIZE

DESIGNATOR 'H' (MTU) IS EQUAL TO 9000 BYTES.

TEST & ACCEPTANCE INSTRUCTIONS:

VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO REQUIRING

ACCESS TO FACILITIES AT BOTH USER LOCATIONS.

ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY PHONE TO THE DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL. PRIMARY: (C) 618-220-9950, (D) 770-9950

TOLL FREE: 855-868-9950

MINIMUM TECHNICAL SPECIFICATIONS:

SPECIFIC FORMAT TO BE USED IS:

LINE RATE: 10.3125 GIGABITS/S, +- 100 PPM LINE CODE: OPTIC

ETHERNET FRAME: 9000 OCTETS (BYTES)

TEST AND ACCEPTANCE: 10GB LAN PHY CIRCUITS SHALL PASS A FULLY DOCUMENTED SATISFACTORY 72 HOUR SOAK TEST BY DISA GOC AT SCOTT AFB, IL. PRIMARY: (C) 618-229-8691 (D) 779-8691

TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING TESTING PARAMETERS SHALL BE

MEASURED DURING TEST AND ACCEPTANCE TESTING. ERROR PERFORMANCE SHALL BE MEASURED AND RECORDED OVER THE DURATION OF THE CONTIGUOUS 24 HOUR TESTING INTERVAL AND SHALL BE

MEASURED AND RECORDED PER DEFINITION IN ITU-T-Y.1564.

ERROR PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN 99.5% OR BETTER. FRAME LOSS SHALL BE EQUAL TO ZERO WHEN TESTING AT 10 GIGABIT HIGHEST FRAME RATE, AND SHALL MEET ITU-T-Y.1564 STANDARDS. JITTER SHALL BE LESS THAN 3 MSEC. DELAY SHALL BE BETTER THAN 10 MSEC

MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER THAN 24 HOURS.

ROUND TRIP DELAY (RTD): RTD SHALL BE MEASURED OVER THE 10GB WAVE CIRCUIT AND SHALL BE

LESS THAN OR EQUAL TO 10 MILLISECONDS.

CIRCUIT SPECIFICATIONS:

CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:

(A) FIBER TERMINATION: FRAME FORMAT: 10GB ETHERNET (OPTICAL HANDOFF-10GB ETHERNET-LAN-

PHY-SINGLE MODE FIBER), 802.3AE, 1310NM. "SC" CONNECTORS.

(B) COMMITTED INFORMATION RATE (CIR) - 10GB.

(C) 10GB ETHERNET - LAN-PHY INTERFACE REQUIRED AT COMMERCIAL DEMARC AT THE A AND Z

LOCATIONS.

(D) ETHERNET FRAME SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM TRANSMISSION UNIT (MTU)

OF 9000 OCTETS (BYTES).

(E) NO NETWORK INTERFACE UNIT, DEDICATED PATH

(F) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO CIRCUIT.

(G) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564 BENCH MARKING CONFIGURATION AND PERFORMANCE OF ETHERNET SERVICE. NOTE-ETHERNET FRAME SIZE

DESIGNATOR 'H' (MTU) IS EQUAL TO 9000 BYTES.

(H) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY, SEVEN DAYS

PER WEEK, AT LEAST 99.5% OR BETTER.

(I) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECIEPT OF TROUBLE.

(J) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES.

(K) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.

(L) TELECOMM PROVIDER MUST MAINTAIN OPERATIONS, MAINTENANCE AND ADMINISTRATION

MONITORING OF ETHERNET CIRCUIT IAW ITU-T-Y.1564.

(M) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY THE DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL. (C) 618-220-8627 (D) 770- 8627.

(N) VENDOR MUST PROVIDE:

THE LONG-HAUL CIRCUIT NO. AND LEC CKT ID'S AS APPLICABLE TO THE DISA IE161 PROGRAM OFFICE

PRIOR TO TURN UP TO THE GOVERNMENT.

VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF 10GBE SERVICE

IAW THE UNIQUE INSTALLATION FACTORS.