This is a work item specification for dockside repairs to the USCGC HUDSON (WLIC 801) during FY2026, specifically for deck covering renewal in interior wet/dry spaces.
The specification requires the contractor to renew deck covering systems in two locations totaling 600 square feet: the Crew Head and Showers (210 sq ft, location 1-111-0-L) and the Galley and Mess Deck (390 sq ft, location 1-131-0-L). Both areas are steel deck and must be covered with Cosmetic Polymeric Epoxy Resin, Type III (One-Step Epoxy System) per SFLC Standard Specification 6341, Appendix A, with cove base installed and new insulating underlayment. The contractor must furnish and install protective coverings to seal off adjacent vessel components and spaces, handle known interferences including tables, galley equipment, shower enclosures, and head fixtures, and remove all protective measures upon completion. Performance requirements include taking 50 ultrasonic thickness measurements of deck plating in Coast Guard-designated locations prior to primer application (per SFLC Std Spec 0740, Appendix C), submitting a color chart for approval, and conducting a visual inspection with a Coast Guard inspector to ensure the installed deck covering is uniform, free of defects, blotchy areas, pooling, ridge marks, and runs, with only negligible embedded surface contaminants. Any imperfections that may cause premature failure must be corrected before acceptance. Work shall be performed in accordance with SFLC Standard Specifications 0000, 0740, and 6341, and referenced Coast Guard drawings 160-WLIC 103-002, 160-WLIC 1106-01, and 160-WLIC 1900-01.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Combined Synopsis.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USCGC HUDSON (WLIC 801)
SPECIFICATION FOR DOCKSIDE REPAIRS
FY2026
Developed By: Erik C Elasik
USCGC HUDSON (WLIC-160A) DOCKSIDE AVAILABILITY FY2026
S_63410_General_0311_SWIT
S25_002_63410_TSI_0825_801
WORK ITEM 17: Deck Covering (Interior Wet/Dry), Renew
1. SCOPE
1.1 Intent. This work item describes the requirements for the Contractor to renew deck covering system(s).
1.2 Government-furnished property.
None.
2. REFERENCES
COAST GUARD DRAWINGS
Coast Guard Drawing 160-WLIC 103-002, Rev A, Booklet of General Plans Coast Guard Drawing 160-WLIC 1106-01, Rev E, Mn Deck Framing & Plating Coast Guard Drawing 160-WLIC 1900-01, Rev J, Painting Schedule
COAST GUARD PUBLICATIONS
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes Surface Forces Logistics Center Standard Specification 6341 (SFLC Std Spec 6341), 2022, Install New Deck Covering Systems
OTHER REFERENCES
None
3. REQUIREMENTS
3.1 General.
3.1.1 CIR. The Contractor shall submit a CIR for the inspections listed in the following paragraph(s):
• None.
3.1.2 Technical Representative. Not applicable.
3.1.3 Protective measures. The Contractor shall furnish and install all protective coverings to seal off and protect all non-affected vessel's components, equipment, and spaces near the work area against contamination during the performance of work. Upon completion of work, the Contractor shall remove all installed protective measures, inspect for the presence of contamination, and return all contaminated equipment, components, and spaces to original condition of cleanliness.
3.1.4 Interferences. The Contractor shall handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences). Known interferences include, but are not limited to the following:
• Tables, benches and cabinets.
• Galley equipment.
• Shower enclosures, pans and drains.
• Head fixtures and piping.
3.2 Deck covering installation particulars. The Contractor shall perform all tasks specified in SFLC Std Spec 6341 and herein, to renew/install a new deck covering system in the location(s) specified in Table I below.
TABLE I - DECKING SYSTEM PARTICULARS
LOCATION AREA
(*SQFT)
DECK
MTL
(A/S**)
SYSTEM/APPENDIX
(SFLC STD SPEC 6341)
COVE
BASE
SYSTEM
COLOR
UNDERLAYMENT
REQUIREMENT
Crew Head and Showers
1-111-0-L 210 S
Cosmetic Polymeric Epoxy Resin, Type III (One-Step Epoxy System)/Appendix A
Yes: X No :__
See para. 3.4
New: X Retain Existing:
Insulating: X None:__
Galley and Mess Deck 1-131-0-L
390 S Cosmetic Polymeric Epoxy Resin, Type III (One-Step Epoxy System)/Appendix A
Yes: X No :
See para. 3.4
New: X Retain Existing:
Insulating: X None:__
TOTAL 600
Cosmetic Polymeric Epoxy Resin, Type III (One-Step Epoxy System)/Appendix A
*Approximated.
**Note: A = Aluminum; S = Steel.
3.3 Ultrasonic thickness measurement. Upon completion of surface preparation and prior to application of primer coat (see 3.2 (Surface preservation)), the Contractor shall take a total of 50 UT measurements of deck plating, in locations designated by the Coast Guard Inspector, in accordance with SFLC Std Spec 0740, Appendix C. Use Coast Guard Drawing 160-WLIC 1106-01 as guidance. Submit a CFR.
3.4 Deck covering color. The Contractor shall submit a deck covering color chart to Coast Guard Inspector, for the purpose of color selection.
3.5 Deck covering inspection. The Contractor in the presence of a Coast Guard inspector shall visually inspect the completely installed and cured deck covering system to ensure that each renewed deck covering system is in accordance with TABLE 1 and is uniform and free of defects. Deck coverings with a sealer coat installed must have a continuous surface, free of blotchy areas, pooling, ridge marks or runs, with only negligible embedded surface contaminants. Air bubbles in the seal coat are acceptable;
however, they must not penetrate any other layers of the deck covering system. Imperfections that may cause premature failure or do not meet the above requirements must be corrected before the surfaces are accepted.
4. NOTES
This section is not applicable to this work item.