CGC HARRIET LANE Port Engine Room Fan SOW.docx
DOCX document 18 KB Posted
- Solicitation number
- 52000QR260023715
About this file
This is a Statement of Work (SOW) for the repair and rebuild of a port engine room ventilation fan motor aboard the USCGC HARRIET LANE. The fan is a Buffalo Forge Co Vane-Axial Fan rated at 25/7.5 HP, 1800/1200 RPM (2-speed), 440 Volt, 33/12 Amps, 3 Phase, Frame 286TNCZ. The motor has failed and requires complete rewinding and testing.
The contractor must perform the following work: disassemble the unit; inspect all external and internal hardware; measure machined surfaces for excessive wear; wash and paint all parts; test the rotor for open bars; remove and rewind the coils after core preparation and cleaning; conduct Meg Ohm, Surge, and Ohm tests on windings; perform high-pot testing after varnishing; replace bearings; and conduct a final reassembly and test run. The period of performance runs from 06 April 2026 through 17 April 2026, with the work to be performed on-site at USCGC HARRIET LANE, 400 Sand Island Parkway, Honolulu, Hawaii 96819. The procurement is issued as Request for Quote Number 52000QR260023715 by the U.S. Coast Guard Surface Force Logistics Center and is designated as a total small business set-aside with firm-fixed price awards under FAR Part 12 simplified acquisition procedures. The related NAICS code is 336611 (Ship Building and Repairing). The Contracting Officer Technical Representative is CWO Ben Peavey at (305) 898-1668 or Benjamin.R.Peavey@uscg.mil.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work (SOW) For repairs to USCGC HARRIET LANE Port Engine Room Ventilation Fan Rebuild
1. Background and Current Observed Issues CGC HARRIET LANE is requesting their engine room ventilation fan motor be rewound and tested due to failure of the unit.
Fan Information:
1. Buffalo Forge Co Vane-Axial Fan
2. HP 25 / 7.5, RPM 1800/1200 2 speed fan
3. 440 Volt 33/12 Amps
4. 3 Phase, Frame 286TNCZ
2. REQUIREMENTS:
Disassemble the unit. Inspect all external and internal hardware. Measure all machined surfaces for excessive wear. Wash and paint all parts. Test the rotor for open bars. Remove the coils. Prep and clean core. Test core integrity. Insulate the stator. Rewind, and connect the motor. Meg Ohm Test, Surge Test an Ohm Test the windings.. After varnishing the motor, conduct a Meg Ohm Test, Surge Test an Ohm Test and Hi pot Test. Replace the bearings. Reassemble and test run.
3. PERIOD OF PERFORMANCE
06 APR 26 – 17 APR 26
4. PLACE OF PERFORMANCE
The primary place of performance shall be CGC HARRIET LANE located at below address:
CGC HARRIET LANE
400 Sand Island Parkway Honolulu, Hawaii 96819
Contracting Officer Technical Representative (COR):
CWO Ben Peavey Cell: (305) 898-1668 Email: Benjamin.R.Peavey@uscg.mil
File details come from the government source that posted it. Updated .