This document is a Specification Sheet for a Centrifugal Purifier that outlines the salient characteristics and technical requirements for the product. The key details include:
The purifier must have a maximum flowrate of 1.0 gpm, minimum flowrate of 0.25 gpm, and 0.10 gallon sludge space. It must be capable of filtering oil with a viscosity range of 1.0 cSt to 30 cSt, with a built-in 1.5kW single-phase heater to adjust viscosity. The unit must operate on 100-230V, single-phase, 50-60Hz power at 10-16 amps, weigh no more than 250 lbs, and have maximum dimensions of 30"x30"x50". It must be a complete, portable, and wheeled system with a 1-gallon minimum collection tank for separated water. The purifier must remove a minimum of 95% of all solid particles between 2-5 microns from MIL-PRF-83282 fluid.
The related federal contract opportunity is a Sources Sought notice issued by the Army Contracting Command-Redstone Arsenal to identify potential sources that can provide centrifugal purifiers meeting these requirements. This is for market research purposes to determine the appropriate procurement method, which could result in a small business set-aside or full and open competition. Responses are voluntary and do not constitute offers or a commitment by the government to award a contract.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Salient Characteristics Centrifugal Purifiers.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS/PRODUCT DESCRIPTION/SPECIFICATION
SHEET
Capacity
1. Maximum Flowrate of 1.0gpm
2. Minimum Flowrate of 0.25gpm
3. Sludge Space 0.10 gallons
4. Capable of filtering Oil with the viscosity of MIL-PRF-83282. Viscosity of 1.0cSt to 30cSt.
5. Single phase heater built in to the unit, to heat fluid in order to raise and lower viscosity.
Minimum 1.5kW.
6.Voltage 100-230Volts;Single Phase;50-60Hz;10-16 Amps
7. Maximum Weight (250lbs)
8. Maximum Dimensions L×W×H (30”×30”×50”)
9. Must be a complete compact system that is portable and on wheels.
10. Collec on tank for separated water (1 Gallon Minimum)
11. Capable of removing minimum 95% of all solid par cles between 2-5 µm from MIL-PRF- 83282.
12. Must have a control unit that is used for star ng, stopping, and supervising the centrifuge.
File details come from the government source that posted it. Updated .