REFURB INST. NO. 5130-012-0729 Rev E Chg-1
CONTRACT DATA REQUIREMENTS LIST
A. CONTR. LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY:
XX TDP TM OTHER
D. SYSTEM/ITEM HPAC
REFURBISHMENT
E. CONTRACT/PR NO. F. CONTRACTOR
CURTISS-WRIGHT
1. DATA ITEM NO. 2. TITLE OF DATA ITEM 3. SUBTITLE
4. AUHORITY (Data Item Descript) 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
7. DD 250 REQ. 9. DIST
STATEMENT
REQUIRED
10. FREQUENCY 12. DATE OF
FIRST
SUBMISSION
14. DISTRIBUTION
DR - DRAFT
RG - REGULAR
RP - REPRO
8. APP CODE 11. AS OF
DATE
13. SUBSEQUENT
SUBMISSION
16. REMARKS
1. A001 2. RECEIPT INSPECTION REPORTS 3.
4. PARA 7.a.(1) 5. PARA 7.a.(1) 6. SUBMEPP
7. SD 9. 10.
AS
REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. Usually NLT 2 Weeks after receipt of GFM.
D R
R G
R P
16. REMARKS SUBMEPP CODE 1831 1
TOTAL 1
1. A002 2. CONDITION REPORT 3.
4. PARA 7.a.(2) 5. PARA 7.a.(2) 6. SUBMEPP
7. SD 9. 10.
AS
REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. Within 10 weeks of the receipt inspection of each component.
D R
R G
R P
16. REMARKS
REPORT TO INCLUDE CONTINGENCY PARTS AND ANY UNPLANNED
PARTS TO BE REPAIRED/REPLACED.
SUBMEPP CODE 1831 1
G. PREPARED BY
//s// T. C. Chan 1846TC
H. DATE
11/16/2018
I. APPROVED BY
//s// Stacy Woodley 1831SW
J. DATE
11/16/2018
DD Form 1423, JUN 90 Previous editions are obsolete Encl (4) Page 1 of 5
DD Form 1423, JUN 90 Previous editions are obsolete Encl (4) Page 2 of 5
A
C. CATEGORY:
XX TDP TM OTHER
D. SYSTEM/ITEM HPAC
REFURBISHMENT
E. CONTRACT/PR NO. F. CONTRACTOR
CURTISS-WRIGHT
1. A003 2. UNPLANNED PARTS USAGE
REPORTS
3.
4. PARA 7.a.(3) 5. PARA 7.a.(3) 6. SUBMEPP
7. SD 9. 10.
AS REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. PRIOR TO SHIPMENT OF
EACH UNIT
D R
R G
R P
16. REMARKS VENDOR’S OWN FORMAT IS ACCEPTABLE. REPAIR
OR REPLACEMENT OF UNPLANNED PARTS MUST BE IN THE BEST
INTEREST OF THE GOVERNMENT AND APPROVED BY THE
GOVERNMENT PRIOR TO ACCOMPLISHMENT.
1. A004 2. REASSEMBLY QUALITY
ASSURANCE REPORT (RQAR).
3.
4. PARA 7.a.(4) 5. PARA 7.a.(4) 6. SUBMEPP
7. SD 9. 10.
AS REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13 PRIOR TO SHIPMENT OF
EACH UNIT
D R
R G
R P
16. REMARKS VENDOR’S OWN FORMAT IS ACCEPTABLE. WELD
MAPS AND SATISFACTORY NDT RESULTS SHALL BE INCLUDED FOR
REPLACEMENT OF ANY PIPING ASSEMBLY. GOVERNMENT
APPROVAL OF WELD/NDT PROCEDURE SHALL BE INCLUDED.
COPY IN CRATE 1
TOTAL 2
1. A005 2. WELDING/BRAZING PROCEDURES &
WELDING PROCEDURE QUAL. TEST
3.
4. REFERENCES (k) and (l) 5. PARA 7.a.(5) 6. SUBMEPP
7. DD 9. 10.
0 TIME
12. 14. DISTRIBUTION
SEE 13 b. Copies
8. A 11.
SEE 13
13. ACCEPTANCE
REQUIRED PRIOR TO
WELDING
D R
R G
R P
16. REMARKS VENDOR’S OWN FORMAT IS ACCEPTABLE.
PRIOR TO WELDING/BRAZING, THE VENDOR’S WELDING/BRAZING
PROCEDURES MUST BE SUBMITTED AND APPROVED.
REQUIRED ONLY IFWELDING/BRAZING TO BE ACCOMPLISHED.
1. A006 2. TEST PROCEDURE 3. LIQUID PENETRANT TEST
PROCEDURES
4. REFERENCE (r) 5. PARA 7.a (6) 6. SUBMEPP
7. DD 9. 10.
0 TIME
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. A 11.
SEE 13
13. ACCEPTANCE
REQUIRED PRIOR TO PT
D R
R G
R P
16. REMARKS VENDOR’S OWN FORMAT IS ACCEPTABLE.
PRIOR TO PT, THE VENDOR’S PT PROCEDURES MUST BE
SUBMITTED AND APPROVED.
TOTAL 3
//s// T. C. Chan 1846TC
H. DATE
11/16/2018
I. APPROVED BY
//s// Stacy Woodley 1831SW
J. DATE
DD Form 1423, JUN 90 Previous editions are obsolete Encl (4) Page 3 of 5
A
C. CATEGORY:
XX TDP TM OTHER
D. SYSTEM/ITEM HPAC
REFURBISHMENT
E. CONTRACT/PR NO. F. CONTRACTOR
CURTISS-WRIGHT
1. A007 2. TEST/INSPECTION REPORTS 3. LIQUID PENETRANT TEST REPORTS
4. REFERENCE (s) 5. PARA 7.a.(7) 6. SUBMEPP
7. SD 9. 10.
AS REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. ACCEPTANCE REQUIRED
PRIOR TO DELIVERY
D R
R G
R P
16. REMARKS
SEE PARA 7.a.(8). REPORTS SHALL BE IDENTIFIABLE TO EACH UNIT BY A
UNIQUE SERIAL NUMBER.
PT REPORTS SHALL REFLECT APPROVED PROCEDURE NUMBER & REV.
1. A008 2. TEST PROCEDURE 3. MAGNETIC PARTICLE TEST
PROCEDURES
4. REFERENCE (r) 5. PARA 7.a.(8) 6. SUBMEPP
7. DD 9. 10.
0 TIME
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. A 11.
SEE 13
13. ACCEPTANCE
REQUIRED PRIOR TO MT
D R
R G
R P
16. REMARKS VENDOR’S OWN FORMAT IS ACCEPTABLE.
PRIOR TO MT, THE VENDOR’S MT PROCEDURES MUST
BE SUBMITTED AND APPROVED.
1. A009 2. TEST/INSPECTION REPORTS 3. MAGNETIC PARTICLE TEST REPORTS
4. REFERENCE (s) 5. PARA 7.a.(9) 6. SUBMEPP
7. SD 9. 10.
AS REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. ACCEPTANCE REQUIRED
PRIOR TO DELIVERY
D R
R G
R P
16. REMARKS
SEE PARA 7.a.(10). REPORTS SHALL BE IDENTIFIABLE TO EACH UNIT BY A
UNIQUE SERIAL NUMBER.
MT REPORTS SHALL REFLECT APPROVED PROCEDURE NUMBER & REV.
1. A010 2. TEST PROCEDURE 3. VISUAL INSPECTION PROCEDURES
4. REFERENCE (r) 5. PARA 7.a.(10) 6. SUBMEPP
7. DD 9. 10.
0 TIME
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. A 11.
SEE 13
13. ACCEPTANCE REQUIRED
PRIOR TO VT
D R
R G
R P
16. REMARKS VENDOR’S OWN FORMAT IS ACCEPTABLE.
PRIOR TO VT, THE VENDOR’S VT PROCEDURES MUST BE
SUBMITTED AND APPROVED.
TOTAL 3
//s// T. C. Chan 1846TC
H. DATE
11/16/2018
I. APPROVED BY
//s// Stacy Woodley 1831SW
DD Form 1423, JUN 90 Previous editions are obsolete Encl (4) Page 4 of 5
A
C. CATEGORY:
XX TDP TM OTHER
D. SYSTEM/ITEM HPAC
REFURBISHMENT
E. CONTRACT/PR NO. F. CONTRACTOR
CURTISS-WRIGHT
1. A011 2. TEST/INSPECTION REPORTS 3. VISUAL INSPECTION REPORT
4. REFERENCE (t) 5. PARA 7.a.(11) 6. SUBMEPP
7. SD 9. 10.
AS REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. ACCEPTANCE REQUIRED
PRIOR TO DELIVERY
D R
R G
R P
16. REMARKS
SEE PARA 7.a.(11)
USING THE CONTRACTOR’S OWN FORMAT TO REPORT RESULTS OF VT AT 5X.
MAGNIFICATION OF THE WELDS
1. A012 2 CERTIFICATION/TEST REPORT 3. CERTIFICATION OF COMPLIANCE
4. REFERENCE (t) 5. PARA 7.a.(12) 6. SUBMEPP
7. SD 9. 10.
AS REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. ACCEPTANCE REQUIRED
PRIOR TO DELIVERY
D R
R G
R P
16. REMARKS Certifying that each unit has been refurbished per RI. One report for each unit, identifiable to the unique ser. Nos. If welding or NDT were accomplished, identify the procedures used, & identify any welding accomplished that that did not require weld procedure qualification tests per reference (j), para 4.2.1.1.
1. A013 2. OPERATIONAL TEST DATA REPORT 3.
4. PARA 7.a.(13) 5. PARA 7.a.(13) 6. SUBMEPP
7. SD 9. 10.
AS REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. ACCEPTANCE REQUIRED
PRIOR TO DELIVERY
D R
R G
R P
16. REMARKS VENDOR’S OWN FORMAT IS ACCEPTABLE.
ALSO SEE PARA 7.a.(13)
1. A014 2. NOISE TEST DATA REPORT 3.
4. PARA 7.a.(14) 5. PARA 7.a.(14) 6. SUBMEPP
7. SD 9. 10.
AS REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. ACCEPTANCE REQUIRED
PRIOR TO DELIVERY
D R
R G
R P
16. REMARKS VENDORS OWN FORMAT IS ACCEPTABLE. SUBMEPP CODE 1831 1
//s// T. C. Chan 1846TC
H. DATE
11/03/2018
I. APPROVED BY
//s// Stacy Woodley 1831SW
11/03/2018
DD Form 1423, JUN 90 Previous editions are obsolete Encl (4) Page 5 of 5
A
C. CATEGORY:
XX TDP TM OTHER
D. SYSTEM/ITEM
HPAC
E. CONTRACT/PR NO. F. CONTRACTOR
CURTISS-WRIGHT
1. A015 2. FINAL INSPECTION REPORT 3.
4. PARA 7.a.(15) 5. PARA 7.a.(15) 6. SUBMEPP
7. SD 9. 10.
AS REQUIRED
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. ACCEPTANCE
REQUIRED PRIOR TO
D R
R G
R P
16. REMARKS
USE ENCLOSURE (2)
1. A016 2. TEST PROCEDURES 3. REPAIR PROCEDURES
4. REFERENCE (r) 5. PARA 7.a.(16) 6. SUBMEPP
7. DD 9. 10.
0 TIME
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. A 11.
SEE 13
13. ACCEPTANCE
REQUIRED PRIOR TO
REPAIRS
D R
R G
R P
16. REMARKS VENDOR’S OWN FORMAT IS
ACCEPTABLE. APPROVAL REQUIRED PRIOR TO REPAIR.
1. A017 2. MERCURY FREE
CONTAMINATION CERTIFICATE
3.
4. PARA 7.a.(17) 5. PARA 7.a.(17) 6. SUBMEPP
7. SD 9. 10.
AS REQD
12.
SEE 13
14. DISTRIBUTION
b. Copies
8. 11.
SEE 13
13. ACCEPTANCE
REQUIRED PRIOR TO
D R
R G
R P
16. REMARKS The contractor is required to certify: (A) Supplies furnished under this contract contain no mercury or mercury containing compounds. (B) The contractor has taken reasonable steps to ensure that supplies furnished under this contract
1. 2. 3.
4. 5. 6.
7. 9. 10. 12. 14. DISTRIBUTION
b. Copies
8. 11. 13 D R
R G
R P
16. REMARKS
TOTAL
G. PREPARED BY
//s// T. C. Chan 1846TC
H. DATE
11/16/2018
I. APPROVED BY
//s// Stacy Woodley 1831SW