CBD212-003.pdf

PDF 64 KB Posted

Attached to
Field Portable Bioaerosol Identification via Mass Spectrometry
Solicitation number
CBD212-003
Issued by

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CBD212-003: Field Portable Bioaerosol Identification via Mass Spectrometry

PROJECTED CMMC LEVEL REQUIREMENT:

N/A

TECHNOLOGY AREAS:

Bio Medical | Chem Bio Defense

MODERNIZATION PRIORITIES:

Biotechnology

KEYWORDS:

Aerosolized pathogens; breath sampling; environmental sampling; biosurveillance

ADDITIONAL INFORMATION

N/A

OBJECTIVE:

Develop a field portable, mass spectrometry-based system that rapidly identifies aerosolized biological particulate, arising from the breath of a warfighter, or from their surrounding environment and the identification technology must be adaptable to the evolution of pathogens both natural and synthetic.

DESCRIPTION:

Aerosolized biological particles are a major vector causing the spread of disease from human to human and from animal to human [1]. This is particularly true for respiratory pathogens such as adenoviruses, influenza viruses, Mycobacterium tuberculosis and coronaviruses such as SARS-CoV-2. Currently, global healthcare systems and governments are in acute crisis because of the worldwide spread of SARS-CoV-2 and the COVID-19 pandemic disease caused by this virus - that arose from animal-to-human transmission. The ability to rapidly, accurately and affordably screen the environment for a wide range of aerosolized pathogens arising from agricultural sources (live animal markets) and human exhaled breath could revolutionize the discovery of emerging pathogens and the ability to identify spreaders of these diseases.

The ability to identify bioaerosols enables a system that could pinpoint persons who are actively shedding pathogen and spreading a disease. Identification of these spreaders, and superspreaders [2], is a vital tool aimed at shutting down the infectious cycle. The enormity and constancy of such a screening protocol argues for testing that is non-invasive, extremely low cost and requires little or no consumables.

In a patient care setting a bioaerosol identification system could be used to monitor the air surrounding the patients for the presence of infectious agent. Constant analysis of the levels of these agents in the air could be used to determine the efficacy of protective measures such as advanced filtration and ventilation on the patients and staff of the facility. Excursions of these measurements above an established baseline could alert personnel to dangerous situations, triggering responses such as donning of enhanced PPE or increasing technical measures such as the air exchange rate in the facility.

Finally, while a bioaerosol identification device has great utility against existing disease states, the tool could provide critical information on potential new organisms originating in agricultural or wildlife settings. Constant monitoring of the air in these environments could provide critical early stage biosurveillance as organisms mutate, potentially resulting in a future pandemic. This mode of operation could be used as a biosurveillance tool and could provide early warning of the rise of a new pandemic threat. If a potential new threat is detected, the signatures of that threat could be propagated through a distributed system of biosurveillance devices.

This technology development focuses on mass spectrometry because it has the potential to meet the following requirements that would enable wide spread use of the technology:

Direct, non-invasive sampling• Rapid automated sample preparation (< 1 min)• Very fast analysis (< 1 min)• High sensitivity (10's of organisms)• High specificity using biomolecular signatures• Rapid adaptability to new/unknown threats through electronic signature updates• Very low cost of analysis (<$1 per test)•

PHASE I:

Phase I entails the design of a concept for a rapid identification system of aerosolized pathogens, identification of key system components and initial testing of those components. The drivers for a technically and commercially successful system will be adaptability, sensitivity, specificity, speed, and cost-per-test. The performer will perform a detailed literature search on the aerosol concentration of pathogens in and around sources of infectious particles to determine the operative sensitivity threshold within proposed use scenarios for their specific detection technology. For certain highly desirable use scenarios, particularly high-throughput screening using human breath samples, an analysis time that is in the 1 minute or less range is preferred. Such a rapid analysis drives a base detection/identification technology that is extremely sensitive, yet it must have sufficient specificity so as not to have unacceptable false alarm rates. Finally, given the massive screening use scenarios, the cost-per-test must be very low. The initial effort in Phase I will be the development of a concept that incorporates the speed, sensitivity, specificity, and cost elements described here. Critical elements or components of the design should be chosen and tested for applicability in the proposed overarching design. Finally, a refined preliminary design should be developed to lead to a proposed Phase II prototype.

PHASE II:

In Phase II, the small business will develop, demonstrate and validate a system for aerosolized biopathogen identification using non-pathogenic simulants of bacterial and viral disease vectors.

Following a Preliminary Design Review (PDR), the performer will assemble and test a breadboard system that has the initial versions of the sampling, analysis, and data reporting subsystems interoperating. This system will be tested using aerosolized biopathogen simulants in relevant laboratory backgrounds. The system will be benchmarked against standard laboratory techniques of biopathogen identification. The key detection/identification parameters will be assessed, and necessary improvements identified. An initial analysis of the commercial applications of the system will be conducted focusing on the baseline cost of the system, the cost-per-test, and the market space addressed by the technology development.

Following the completion of the preliminary design system, the performer will upgrade the breadboard system with modifications that address deficiencies identified in testing and analysis, and leading to a Critical Design Review (CDR). Following this review, a complete prototype system will be fabricated and tested in a relevant environment. Depending on the ultimate use case for the technology, this could be a human disease sampling effort, or it could be an environmental testing scenario in a hospital unit or in an agricultural setting. The performer will provide a detailed test plan that must contain human usage approvals, if such testing is anticipated. A refined analysis of the commercial opportunities for the technology also will be completed.

PHASE III DUAL USE APPLICATIONS:

PHASE III: Phase III work is typically oriented towards technology transition to Acquisition Programs of Record and/or commercialization of SBIR research or technology. In Phase III, the performer is expected to seek funding from non-SBIR government sources and/or the private sector to develop or transition the prototype into a viable product or service for sale in the military or private sector markets. The Phase III description must include the "vision" or "end-state" of the research. It must describe one or more specific Phase III military applications and/or supported S&T or acquisition program as well as the most likely path for transition of the SBIR from research to operational capability. Additionally, the Phase III section must include (a) one or more potential commercial applications OR (b) one or more commercial technology that could be potentially inserted into defense systems as a result of this particular SBIR project.

PHASE III DUAL USE APPLICATIONS: A rapid, sensitive, specific, low-cost approach to identification of bioaerosol components will have application beyond DoD needs. The ability to rapidly screen persons transmitting disease could revolutionize the control of infectious disease spread. For instance, Homeland Security components such as Transportation Security Agency (TSA) and Customs and Border Protection (CBP) could employ such a system to screen disease spreaders at transportation hubs and border crossings. In agricultural applications, such a system could signify the spread of a disease through a feedlot or even the emergence of a potential new vector for human disease.

REFERENCES:

Infection Prevention and Control of Epidemic- and Pandemic-Prone Acute Respiratory Infections in Health Care. Geneva: World Health Organization; 2014. (https://www.who.int/news-room/commentaries/detail/transmission-of-sars-cov-2-implications-for-infection-prevention-precautions);

1.

Frieden, T. R., & Lee, C. T. (2020). Identifying and Interrupting Superspreading Events—Implications for Control of Severe Acute Respiratory Syndrome Coronavirus 2. Emerging Infectious Diseases, 26(6), 1059- 1066. (https://dx.doi.org/10.3201/eid2606.200495);

2.

Yadana, S., Coleman, K. K., Nguyen, T. T., Hansen-Estruch, C., Kalimuddin, S., Thoon, K. C., Low, J., & Gray, G. C. (2019). Monitoring for airborne respiratory viruses in a general pediatric ward in Singapore. Journal of public health research, 8(3), 1407. (https://doi.org/10.4081/jphr.2019.1407)

3.

TECHNICAL POINT OF CONTACT (TPOC):

None

File details come from the government source that posted it. Updated .